Product Safety and the use of EMC techniques to evaluate the 30 Amp Ground continuity test

Size: px
Start display at page:

Download "Product Safety and the use of EMC techniques to evaluate the 30 Amp Ground continuity test"

Transcription

1 Product Safety and the use of EMC techniques to evaluate the 30 Amp Ground continuity test Ron Duffy Product Safety Engineer Agilent Technologies, Inc Richard Georgerian Product Compliance Engineer Carrier Access Corporation Technical Presentation - October 3,

2 TDR continued. Plot 1 is a good ground connection. Plot 2 is the same, a good ground connection with the ground lead dressed against the rear panel. By examining the two plots one can conclude the TDR is not a good method to prove a good ground connection. Plot 1. Plot 2. Technical Presentation - October 3,

3 Impedance Analyzer Test Setup An impedance analyzer was used to examine the grounding system. The impedance analyzer was first connected to a known good ground. Figure 3. Technical Presentation - October 3,

4 Impedance Analyzer Test Setup continued. Plot 3 shows the result of the good ground as tested with the impedance analyzer. The screw holding the ground lug was then loosened one-quarter turn. The impedance analyzer did not show the loose screw. This is shown by Plot 4. Horz = 78mV/div Vert = 2.60V/div Start Freq = 5Hz; Stop Freq = 13MHz; Step = 500kHz Horz = 78mV/div Vert = 2.60V/div Start Freq = 5Hz; Stop Freq = 13MHz; Step = 500kHz Plot 3. Plot 4. Technical Presentation - October 3,

5 Triggered Oscilloscope Method Apply a direct current high impedance source across the grounding system. 5kohms To oscilloscope 5Vdc Ground System Figure 4. Schematic 1. Technical Presentation - October 3,

6 Triggered Oscilloscope Method continued. Inducing mechanical energy into the product will trigger the oscilloscope if the connection is loose. Shaking, or a two to four inch bench drop, will work. Horz: 1ms/div Vert: 2V/div Plot 5. Technical Presentation - October 3,

7 Thirty Ampere Ground Test The right value to insure the incoming mains power protection system, fuse or circuit breaker, will operate. Some standards may specify other currents and/or times. Previous 30 amp testing did not prove defective ground connections would be found. Visual inspection was the only way. Technical Presentation - October 3,

8 Thirty Ampere Ground Test continued. A measurement method that was accurate and allowed control of time and current was used. Digital Voltmeter Precision resistor Current probe Pulse generator Constant Current generator Oscilloscope Current flow Ground System Differential probe Current flow Figure 5. Schematic 2. Technical Presentation - October 3,

9 Thirty Ampere Ground Test continued. The thirty ampere ground test was divided into five parts. 1. Bench mark: Using the split-half method. 2. Loose screw: One-quarter turn loose. 3. Wire crimped, no solder. 4. Loose crimp 5. Cut strands Technical Presentation - October 3,

10 Thirty Ampere Ground Test continued. Bench mark Thirty amperes was conducted through a known good ground as a bench mark. Refer to Plot 6. Plot 7, Benchmark 47.7 amperes without damage. Horz = 20sec/div Vert = 20mV/div Delta = 9mV Plot 6. Horz = 20sec/div Vert = 40mV/div Delta = 43.8mV Plot 7. Technical Presentation - October 3,

11 Thirty Ampere Ground Test continued. Loose screw Before applying benchmark current, a thirty ampere ground test was performed. Comparing the voltage waveform to the benchmark, the loose screw was detected. Technical Presentation - October 3,

12 Thirty Ampere Ground Test continued. Loose screw continued. Apply the bench mark current of 47.7 amperes: The loose screw increases the resistance. Result: Smoking at the crimp, insulation overheating, and discoloration of the lug. Horz = 20sec/div Vert = 100mV/div Delta = - 206mV Plot 8. Technical Presentation - October 3,

13 Thirty Ampere Ground Test continued. Wire crimped, no solder. Apply the bench mark current of 47.7 amperes: A wire was fastened but no solder was applied. Result: The ground passed the thirty ampere test but not the bench mark test. Horz = 20sec/div Vert = 200mV/div Delta = 56.3mV Plot 9. Technical Presentation - October 3,

14 Thirty Ampere Ground Test continued. Loose Crimp Apply the bench mark current of 47.7 amperes: The wire strands were inserted in the lug but not crimped. Result: Heating occurred at the lug, causing blistering of the insulation. Horz = 20sec/div Vert = 60mV/div Delta = 80.6mV Plot 10. Technical Presentation - October 3,

15 Thirty Ampere Ground Test continued. Loose Crimp continued. Cautionary note: If the strands in the uncrimped lug are making good electrical contact because of sideways pressure the benchmark will not work. The sideways pressure might be caused by the lead being dressed with a cable tie so that the wire in the lug is forced to one side of the crimp. Technical Presentation - October 3,

16 Thirty Ampere Ground Test continued. Cut strands 18AWG stranded wire, 34 strands. Groups of four strands were cut until it was determined that the benchmark test would show a cut strand connection. Result: After a total of 20 strands out of 34 (59%) were cut, the ground system failed the benchmark test. In all cases the thirty ampere ground test found no failures. Technical Presentation - October 3,

17 Thirty Ampere Ground Test continued. Cut strands continued. Chart 1 details the cut strand experiment. If one was very familiar with the benchmark system, one could see the resistance changes with the cut strands Cut 4 strands out of 34 stranded wire. Cut 8 strands out of 34 stranded wire. Cut 12 strands out of 34 stranded wire. Cut 16 strands out of 34 stranded wire. Cut 20 strands out of 34 stranded wire Constant Current (amps) Rdelta(ohms) Chart Passed Passed Passed Passed Passed Passed Passed Passed. Began to smoke at 90 sec. Passed Failed S T U V W X Y Z AA AB Experiment # Technical Presentation - October 3,

18 Redundant grounds One hundred amperes was passed through this ground system. Result: No failure. Technical Presentation - October 3,

19 Recommendations Benchmark during product development. Archive the benchmark's voltage waveforms and current value. Technical Presentation - October 3,

20 Conclusion TDR and sweepers cannot find faulty ground. The triggered oscilloscope method may find loose screws. The benchmark current test can find loose screws, crimped but not soldered joints, and cut strands if more than half the strands are cut. Redundant grounds are robust enough to defy all high current testing. There will always be cases that require visual inspection to determine good ground systems. Technical Presentation - October 3,

21 Abstract Required by most standards. Test performed to ensure that ground has been assembled properly. The test does not ensure quality earthing connections. Explored other techniques to detect poor quality grounding system. Technical Presentation - October 3,

22 Introduction Different techniques were used. A more reliable and robust method to determine good ground continuity was found. Methods were found that would non-visually prove a good ground connection. Technical Presentation - October 3,

23 Description of ground system Earth ground wire Solder lug Crimp lug Screw Standoff Figure 1. Technical Presentation - October 3,

24 TDR Test Setup The TDR could not detect a bad connection. Found to be sensitive to lead dress. Figure 2. Technical Presentation - October 3,

RPS900W Redundant Power Supply. Installation Guide.

RPS900W Redundant Power Supply. Installation Guide. RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A

More information

May08 Rev B

May08 Rev B Qualification Test Report 0.64 mm Generation Y Terminal 501-657 20May08 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on the Tyco Electronics 0.64 mm Generation Y Terminal to determine its conformance

More information

GENERAL APPLICATION NOTES

GENERAL APPLICATION NOTES GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical

More information

Agilent Wedge for Probing High-Pitch ICs A Hands-Free Solution for Probing Fine-Pitch ICs

Agilent Wedge for Probing High-Pitch ICs A Hands-Free Solution for Probing Fine-Pitch ICs Agilent Wedge for Probing High-Pitch ICs A Hands-Free Solution for Probing Fine-Pitch ICs Application Note Making reliable, nondestructive connections to 0.5 and 0.65 mm components Table of Contents 2

More information

CCSSL35 Carry out the wiring and testing of electrical circuits and equipment

CCSSL35 Carry out the wiring and testing of electrical circuits and equipment Carry out the wiring and testing of electrical circuits and equipment Overview This standard is about the basic competences that you need to wire up and test electrical equipment and circuits for the theatre

More information

Polatrak ROV II - Tip Contact Probe Operation Manual

Polatrak ROV II - Tip Contact Probe Operation Manual This PDF document contains Live Web Links Click them for more information from the web Polatrak ROV II - Tip Contact Probe Operation Manual A Cathodic Protection Probe with dual Ag/AgCl reference cells

More information

Stand-Alone Bubble Detection System

Stand-Alone Bubble Detection System Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When

More information

POWR-BLOKS Distribution/Splicer Blocks and Covers

POWR-BLOKS Distribution/Splicer Blocks and Covers SPECIFICATIONS Voltage : 600V erage: Based on NEC Table 310-16, using 75 C copper wire Material: Phenolic rated at 150 C and Thermoplastic rated at 125 C (LD1400 and LS1300 series only) : Standard: Highly

More information

Teacher s Assistant Laboratory Guide

Teacher s Assistant Laboratory Guide Teacher s Assistant Laboratory Guide Joseph B. Hakanson 1, Warner Meeks 2, and Dr. Joshua L. Rovey 3 Missouri University of Science and Technology, Rolla, Missouri, 65409 These instructions will discuss

More information

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Table of Contents

More information

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2 The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control

More information

It is essential that the maintenance staff is qualified for electrical works and follows safety procedures.

It is essential that the maintenance staff is qualified for electrical works and follows safety procedures. MAINTENANCE OF POWER FACTOR CORRECTION EQUIPMENTS Procedures, suggestions and traceability The purpose of this document is to propose a maintenance method that allows to identify the elements to be maintained

More information

Gas Network Craftsperson

Gas Network Craftsperson Gas Network Craftsperson Unit EIAU06 Maintaining Instrumentation and Control Equipment Circuits This assessment specification has been developed as part of the network maintenance craftsperson standard

More information

SEMPEO SQA Unit Code FP3T 04 Maintaining electronic equipment/systems

SEMPEO SQA Unit Code FP3T 04 Maintaining electronic equipment/systems Overview This standard covers a broad range of basic electronic maintenance competences that will prepare you for entry into the engineering or manufacturing sectors, creating a progression between education

More information

SEMME2135 Assisting in modifying and adding electrical circuits in yachts and boats

SEMME2135 Assisting in modifying and adding electrical circuits in yachts and boats Assisting in modifying and adding electrical circuits in yachts and boats Overview This standard identifies the competences you need to assist with the modification or addition of electrical circuits in

More information

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6 NEUTRAL GROUNDING RESISTORS INSTALLATION, OPERATION & MAINTENANCE MANUAL Contents 1- SAFETY INSTRUCTIONS... 3 1-1- Compliance with Instructions in this Manual. 3 1-2- Guidance Notes Installation.... 3

More information

Aqua Control, Inc. 60Hz. BOTTOM CIRCULATOR INSTRUCTION MANUAL TABLE OF CONTENTS

Aqua Control, Inc. 60Hz. BOTTOM CIRCULATOR INSTRUCTION MANUAL TABLE OF CONTENTS Aqua Control, Inc. 60Hz. BOTTOM CIRCULATOR INSTRUCTION MANUAL TABLE OF CONTENTS PAGE PAGE Safety 1 Anchoring Anchoring Instructions 6 Installation / Launching Floating of the Bottom Circulator 2 Sinking

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual 1194 Oak Valley Drive, Suite 20, Ann Arbor, MI 48108 800-959-0573 734-769-1888 Content Page For your Safety 3 General Description 3 Detection Principle 4 Operation 4

More information

QPEO2/033N Credit Value: 14 QCF Level: 2 GLH: 64 Wiring and testing electrical equipment and circuits

QPEO2/033N Credit Value: 14 QCF Level: 2 GLH: 64 Wiring and testing electrical equipment and circuits Performing Engineering Operations QPEO2/033N Credit Value: 14 QCF Level: 2 GLH: 64 Wiring and testing electrical equipment and Learner Name: EAL Assessment Route Summary This EAL assessment route covers

More information

Ground Fault Circuit Interrupter(GFCI) Policy

Ground Fault Circuit Interrupter(GFCI) Policy NewStar Netronics, LLC American Products for the World Ground Fault Circuit Interrupter(GFCI) Policy 3926 East 3 rd Street Tulsa, OK 74112 Phone (918)894-5006 Fax (918)836-9909 tech@newstarnetronics.com

More information

SEMEM3-65 Servicing anaesthetic and ventilation equipment

SEMEM3-65 Servicing anaesthetic and ventilation equipment Overview This unit identifies the competences you need to carry out servicing activities on anaesthetic and ventilation equipment, in accordance with approved procedures. You will be required to service

More information

SC505 Sof Care Inflator. Operating Instructions and Service Manual

SC505 Sof Care Inflator. Operating Instructions and Service Manual SC505 Sof Care Inflator Gaymar Industries, Inc. 10 Centre Drive Orchard Park, NY 14127 Toll Free +1 800.828.7341 + 1 716.662.2551 Fax +1 800.993.7890 Outside USA +1 716.662.8636 Outside USA Fax +1 716.662.0730

More information

Medium Voltage Switchgear. Installation Manual for Pressure Relief Ducts

Medium Voltage Switchgear. Installation Manual for Pressure Relief Ducts Uniswitch Medium Voltage Switchgear Installation Manual for Pressure Relief Ducts TABLE OF CONTENTS 1 Summary... 1 2 Transportation and storage... 2 2.1 Condition on delivery... 2 2.2 Unpacking at installation

More information

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

References 6 k thermal overload relays, adjustable from 0.11 to 16 A s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure

More information

Gas Network Craftsperson

Gas Network Craftsperson Gas Network Craftsperson Unit EIAU016 Carrying out Fault Diagnosis on Electrical Equipment and Circuits This assessment specification has been developed as part of the network maintenance craftsperson

More information

5 th year (Control department)

5 th year (Control department) Benha Faculty of Engineering Benha University 5 th year (Control department) Clinical Equipment Management(E527) Examiner: Dr.Waleed A.A Salem Final Written Examination 2012 / 2013 Time : Three Hours Answer

More information

ES18 Security Theory/Regulations Answer Schedule

ES18 Security Theory/Regulations Answer Schedule ES18 Security Theory/Regulations Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The marker

More information

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS 2561762B REV. B 210 Printed in U.S.A. INSTALLATION AND SERVICE INSTRUCTIONS

More information

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax) PER CO # 33537 Approved By: M. Bartell Originator: Checked By: S. Jackson B. Cornelius 1 of 8 ODN-084-23 23 TITLE: Installation and Operation Manual for Dry- Teledyne Oil & Gas 1026 North Williamson Blvd.

More information

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor

More information

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions PLAQUE MFM0680 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM0680... 4 Power Supply Unit MPS021000

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

Ventam 85 Installation & Commissioning Instructions

Ventam 85 Installation & Commissioning Instructions Ventam Systems Ltd Unit D4 Seedbed Business Centre Vanguard Way Shoeburyness Essex SS3 9QY Phone 01702 382 307 Fax 01702 382 340 Ventam 85 Installation & Commissioning Instructions 1 General The Ventam

More information

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE 1 These instructions generally describe the installation, operation, and maintenance of subject equipment. The manufacturer reserves the right

More information

User s Guide Temperature Sensor Converter TSC-599

User s Guide Temperature Sensor Converter TSC-599 User s Guide Temperature Sensor Converter TSC-599 ILX Lightwave Corporation 31950 Frontage Road Bozeman, MT, U.S.A. 59715 U.S. & Canada: 1-800-459-9459 International Inquiries: 406-556-2481 Fax 406-586-9405

More information

powr-bloks POWR-GARD Fuseblocks Distribution/Splicer Blocks and Covers Applications Connectors Description Ampere Ratings Specifications

powr-bloks POWR-GARD Fuseblocks Distribution/Splicer Blocks and Covers Applications Connectors Description Ampere Ratings Specifications powr-bloks Applications Typical applications include heating, air conditioning and refrigeration systems, el e va tor systems, material handling equipment, control panels, motor controls, switchgear, and

More information

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM Arbor Terminator Press Operation Manual For IDT Connectors Order No. 11-20-0815 Engineering No: AM7223-140 Description Operation Maintenance Order No: TM-011200815 Release Date: 03-08-12 UNCONTROLLED COPY

More information

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection SG33KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG33KTL-M. In no case shall this guide substitute for the user manual or related notes on

More information

IntelliChlor Power Center (For use with IntelliChlor model IC60, IC40 and IC20)

IntelliChlor Power Center (For use with IntelliChlor model IC60, IC40 and IC20) IntelliChlor Power Center (For use with IntelliChlor model IC60, IC40 and IC20) Patents pending Certified to NSF/ANSI 50 Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

ISA-40M Oxygen Monitor For MRI Scanner Applications For P/N s

ISA-40M Oxygen Monitor For MRI Scanner Applications For P/N s ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 ISA-40M Oxygen Monitor For MRI Scanner Applications For P/N s 04615-001 04615-101 04615-002 04615-102 04615-003 04615-103 04615-004 04615-104 80015-102

More information

CS10 # Network Safety Performance Objectives (2016)

CS10 # Network Safety Performance Objectives (2016) CS10 #4384287 Network Safety Performance Objectives (2016) Context & Purpose The Horizon Power Network Safety Objectives (2016) (Objective Statement) has been prepared for each of network safety performance

More information

Product Specification

Product Specification Ultrasonic Cold Water Meter Body Part Number: HS0014-000 Model Number: RC15/HS-US0004-000-01 Overview The Ultrasonic Cold Water Meter Body is comprised of a pair of ultrasonic flow sensors and a DN15 polymer

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

Safety Powder Spray Systems

Safety Powder Spray Systems Instruction Sheet P/N 107 952C Safety Powder Spray Systems 1. Introduction This section contains general safety instructions for using your Nordson equipment. Task- and equipment-specific warnings are

More information

SVS MINI 4 LIFT INSTALLATION INSTRUCTIONS (220V)

SVS MINI 4 LIFT INSTALLATION INSTRUCTIONS (220V) SVS MINI 4 LIFT INSTALLATION INSTRUCTIONS (220V) SVS, INC. 2513 Jenks Ave Panama City, FL 32405 www.svslifts.com Lifting Your Image Tel: 850-522-4747 Fax: 850-522-4739 sales@svslifts.com International

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

For ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35

For ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35 INSTALLATION AND OPERATING INSTRUCTIONS ANCHOR WINCHES For ELECTRIC ANCHOR WINCH Models: T10109-35 Pontoon 35 T10102-35sw Salt Water Series Coastal 35 If you have any questions or difficulty installing

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information

! Warning, refer to accompanying documents.

! Warning, refer to accompanying documents. About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

General electrical and electronic engineering applications

General electrical and electronic engineering applications Unit 067 General electrical and electronic engineering applications Level: 2 Credit value: 12 NDAQ number: 500/9514/6 Unit aim This unit covers the skills and knowledge needed to prove the competences

More information

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT 200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

Type 715P/717P, Orange Drop, High Voltage, Polypropylene Film/Foil

Type 715P/717P, Orange Drop, High Voltage, Polypropylene Film/Foil Type 715P/717P are high AC voltage, film/foil polypropylene capacitors. Well suited for high AC voltage applications requiring corona free performacnce. These capacitors are ideal in high frequency, high

More information

PRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A

PRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A SFP+ Cage and Cage Assembly 1 of 8 A 1.0 Objective This specification defines the performance, test, quality and reliability requirements of the _Small Form-factor Pluggage (SFP+) product. 2.0 Scope This

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

RAI-M series RUDDER ANGLE INDICATOR SYSTEM

RAI-M series RUDDER ANGLE INDICATOR SYSTEM RUDDER ANGLE INDICATOR SYSTEM RAI-M series SEAFIRST ENGINEERING CO 45-16, Ga Um Dong, Chang Won, Kyong Nam Korea Tel : 82 55 267 1645 Fax ; 82 55 266 1646 http://www.seafirst.co.kr GENERAL Seafirst Rudder

More information

Maintaining electrical equipment/systems

Maintaining electrical equipment/systems Unit 037 Maintaining electrical equipment/systems Level: 2 Credit value: 15 NDAQ number: 500/9514/6 Unit aim This unit covers the skills and knowledge needed to prove the competences required to cover

More information

Inspection and Testing Pocket Notes

Inspection and Testing Pocket Notes Inspection and Testing Pocket Notes of Initial Verification Periodic Inspection Purpose of Information required by inspector 1. All equipment is correct type and complies with relevant British Standard

More information

CS115 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

CS115 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL CS115 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL 3/03 COPYRIGHT (c) 2002-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE This equipment is warranted by CAMPBELL SCIENTIFIC

More information

Circuit diagnosis. Plan of attack Testing techniques and analysis. Failures causes and patterns

Circuit diagnosis. Plan of attack Testing techniques and analysis. Failures causes and patterns Circuit diagnosis Plan of attack Testing techniques and analysis Verification Failures causes and patterns Circuit Diagnosis - Plan of attack In general the process of diagnosis is abut keeping facts and

More information

MARATHON SENSORS INC. TROUBLESHOOTING A CARBON PROBE

MARATHON SENSORS INC. TROUBLESHOOTING A CARBON PROBE When there is a problem making consistent product in a carborizing furnace you must consider all the possibilities before replacing the oxygen sensor. In many cases using the sensor and the control instrument

More information

DPC-30 DPC-100. Reference Manual

DPC-30 DPC-100. Reference Manual DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,

More information

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions PLAQUE MFM18240 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM18240... 4 Power Supply Unit MPS061000

More information

14" 10A ELECTRIC DETHATCHER

14 10A ELECTRIC DETHATCHER 14" 10A ELECTRIC DETHATCHER 27022 Owner s Manual TOLL-FREE HELPLINE: 1-888-90WORKS (888.909.6757) Read all safety rules and instructions carefully before operating this tool. CONTENTS Contents... 2 Specifications...

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services

You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services Why Failures Occur Insulation Failure - Every electrical component is comprised of

More information

QPEO2/037N Credit Value: 15 QCF Level: 2 GLH: 68 Maintaining electrical equipment/systems

QPEO2/037N Credit Value: 15 QCF Level: 2 GLH: 68 Maintaining electrical equipment/systems Performing Engineering Operations QPEO2/037N Credit Value: 15 QCF Level: 2 GLH: 68 Maintaining electrical equipment/systems Learner Name: 2013 Excellence, Achievement & Learning Ltd EAL Assessment Route

More information

Electrical. OSHA Office of Training and Education 1

Electrical. OSHA Office of Training and Education 1 Electrical OSHA Office of Training and Education 1 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due

More information

SMARTen STP Patch Cords Features

SMARTen STP Patch Cords Features Features Patch Cords are used in the work area and cross-connect generic cabling applications Comprise a length of eight-wire flexible patch cable, terminated with two eight-position RJ-45 plugs at each

More information

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. . User Manual Capacitance Continuous Level Indicator Comprehensive User s Manual. Introduction. General Description. Principle of Operation. Specifications. Connection Diagrams. Quick Calibration Chart.

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT)

Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT) Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT) Reviews and Revisions Action Date Reason Reviewer Updated details of External PAT Contractor 17/02/16 New contract

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit

More information

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical

More information

For ANCHOR WINCH Model: T Big Water 45 T sw Salt Water Series Big Water 45

For ANCHOR WINCH Model: T Big Water 45 T sw Salt Water Series Big Water 45 INSTALLATION AND OPERATING INSTRUCTIONS ANCHOR WINCHES For ANCHOR WINCH Model: T10110-45 Big Water 45 T10103-45sw Salt Water Series Big Water 45 If you have any questions or difficulty installing this

More information

Karandikar Laboratories Pvt. Ltd., Gat No. 142, Boisar Chilhar Road, At Betegaon, Boisar (E), Taluka Palghar, Maharashtra

Karandikar Laboratories Pvt. Ltd., Gat No. 142, Boisar Chilhar Road, At Betegaon, Boisar (E), Taluka Palghar, Maharashtra Last Amended on - Page 1 of 41 1 SAFETY 1. Safety Testing IEC 61010:2010 Single Fault Conditions IEC 61010-1 Cls. 4.4 And Similar Visual checks Verification of electrical parameters given on label IEC

More information

Fiber Cable Puller with Tuf-Lugger lite

Fiber Cable Puller with Tuf-Lugger lite 7 OPERATING INSTRUCTION MANUAL Fiber Cable Puller with Tuf-Lugger lite Copyright 2015 DCD Design & Manufacturing Ltd. Revision 1.0 IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING The Fiber

More information

LENNOX SLP98UHV DIAGNOSTIC CODES

LENNOX SLP98UHV DIAGNOSTIC CODES Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! INLET PRESS TAP WHITE-RODGERS 36E93-304 Delay-Opening Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information

Size Selection & Installation of QSZH-125

Size Selection & Installation of QSZH-125 Product Installation Procedure (PIP) No: PIP-101 Revision: 2 Dated: January 2012 Title:- Size Selection & Installation of QSZH-125 Prepared By: Name: Clive Benning Date: January 2012 Reviewed & Approved

More information

Electrical Shore Connections

Electrical Shore Connections RULES FOR CLASSIFICATION OF Ships / High Speed, Light Craft and Naval Surface Craft PART 6 CHAPTER 29 NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS Electrical Shore Connections JULY 2014

More information

Procedure Troubleshooting the Interconnect Cables

Procedure Troubleshooting the Interconnect Cables Procedure 6.1 - Troubleshooting the Interconnect Cables Troubleshooting the upper interconnect cable 1. Remove the display housing per Procedure 7.13. Disconnect the upper interconnect cable from the upper

More information

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection SG36KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG36KTL-M. In no case shall this guide substitute for the user manual or related notes on

More information

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii Operator s Manual Table of Contents Operator Safety... 1 Introduction... 2 Unpacking and Setup... 3 Unpacking... 3 Setup... 4 FLYER Overview... 5 FLYER Diagram... 5 Capabilities... 5 Control Panel... 6

More information

Safe Schools: A Health and Safety Check

Safe Schools: A Health and Safety Check Name of School: Optional Information Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Use of Electrical Equipment Self-Inspection Checklist Guidelines: This checklist covers

More information

TSE Blood Pressure Monitor Invasive series

TSE Blood Pressure Monitor Invasive series TSE Blood Pressure Monitor Invasive 209100series For Invasive Measurements in Laboratory Animals 2 Specifications subject to change without notice USA / Canada / Mexico Phone 1-989-698-3067 Fax 1-989-698-3068

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

Low Wind High Yields Series

Low Wind High Yields Series Low Wind High Yields Series Wind Turbines USER S MANUAL Introduction Low Wind High Yields Series rotor blades apply the latest advanced thermoplastic engineering and are manufactured by precision injection

More information

Electrical Safety PPT-SM-ELECTSFTY V.A.0.0

Electrical Safety PPT-SM-ELECTSFTY V.A.0.0 Electrical Safety 1 Electrical Safety OSHA s electrical safety standard covers Work on or near exposed energized equipment Proper use of electrical protective equipment Safe use of portable electric equipment

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS APPLICATION NOTE LC-136 Introduction Specialized spaces often times must

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS INLET PRESS TAP WHITE-RODGERS 36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

Current Leads for Cryogenic Systems

Current Leads for Cryogenic Systems Current Leads for Cryogenic Systems American Magnetics Inc. s (AMI) Vapor Cooled Current Leads provide reliable and consistent electrical current transfer from room temperature (300K) to a Liquid Helium

More information

Sensoric 4-20 ma Transmitter Board Operation Manual

Sensoric 4-20 ma Transmitter Board Operation Manual Sensoric 4-20 ma Transmitter Board Operation Manual 1 Content Features Operation Manual Technical Data Mechanical Dimensions Remarks & Contact information 2 Features Soldered sensor cell (non replaceable)

More information

frequently asked questions

frequently asked questions Hydra Pilot Fault Codes What do the fault codes for the Hydra Pilot mean? Fault Cause FAULT 100 FAULT 101 FAULT 102 FAULT 103 FAULT 104 FAULT 105 FAULT 106 FAULT 108 FAULT 109 FAULT 110 FAULT 111 FAULT

More information