RPNK. Heat Pumps. Parts List 25-July-2011
|
|
- Melinda Richard
- 5 years ago
- Views:
Transcription
1 Parts List This parts list is current as of the above revision date. See for the current revision. Heat Pumps
2 Table of Contents Model Explanation Page 3 Parts Numbers Panels - Miscellaneous Page 4 Electrical Group Page 5 Fan Group Page 5 Coil Parts Page 6 Compressor Group Page 7 Accessories Page 7 Drawings/Photographs Exploded View Page 8 Control Box Assembly Page 9 Notes/Disclaimer Page 10 Page 2 of
3 MODEL NUMBER EXPLANATION R P N K J A Z (1) (2) (3) (4) (5) (6) (7) (8) (1) TRADEBRAND IDENTIFICATION (6) ELECTRICAL DESIGNATION J= /1/60 (2) MODEL P= HEAT PUMP (7) VARIATIONS A= FULL FEATURED (3) TYPE (8) COMPRESSOR (4) DESIGN SERIES / VARIATION Z= SWEAT W/ SCROLL (5) 018 = 18,000 BTU/HR 024 = 24,000 BTU/HR 036 = 36,000 BTU/HR 048/049 = 48,000 BTU/HR 060/061 = 60,000 BTU/HR SERIAL NUMBER EXPLANATION M (1) (2) (3) (4) (5) (1) COMPRESSOR IDENTIFICATION NUMBER (2) PRODUCTION LOCATION M = MILLEDGEVILLE, GA (3) WEEK OF PRODUCTION (4) YEAR OF PRODUCTION (5) PRODUCTION NUMBER Page 3 of
4 SHEET METAL PARTS, MISCELLANEOUS 1 Base Pan AE AE AE AE AE Button Plug Cabinet AE AE AE AE AE Top Panel AE AE AE AE AE Grille Control Box AE AE AE AE AE a Capacitor Adapter Plate (2 in. round capacitor) AE AE AE AE AE a Capacitor Adapter Plate (2 in. X 1-1/4 in. oval capacitor) AE AE AE AE AE b Capacitor Strap - Start Capacitor AE AE AE AE AE Access Panel AE AE AE AE AE Service Valve - Suction Service Valve - Liquid Touch-up Paint (Aerosol) Touch-up Paint (Paint Pens) SHEET METAL PARTS, MISCELLANEOUS 1 Base Pan AE AE AE AE Button Plug Cabinet AE AE AE AE Top Panel AE AE AE AE Grille Control Box AE AE AE AE a Capacitor Adapter Plate (2 in. round capacitor) AE AE AE AE a Capacitor Adapter Plate (2 in. X 1-1/4 in. oval capacitor) AE AE AE AE b Capacitor Strap - Start Capacitor AE AE AE AE Access Panel AE AE AE AE Service Valve - Suction Service Valve - Liquid Touch-up Paint (Aerosol) Touch-up Paint (Paint Pens) Page 4 of
5 ELECTRICAL GROUP CONTROL BOX COMPONENTS: 10 Stk Defrost Control Board Stk Contactor Capacitor - Compressor/Fan See Compressor Group 13 Start Relay See Compressor Group 14 Capacitor - Compressor Start See Compressor Group ELECTRICAL GROUP CONTROL BOX COMPONENTS: 10 Stk Defrost Control Board Stk Contactor Capacitor - Compressor/Fan See Compressor Group 13 Start Relay See Compressor Group 14 Capacitor - Compressor Start See Compressor Group FAN GROUP 18 Stk Fan Motor Capacitor - Fan Motor See Compressor Group 19 Stk Fan Blade FAN GROUP 18 Stk Fan Motor Capacitor - Fan Motor See Compressor Group 19 Stk Fan Blade Page 5 of
6 COIL GROUP 8 Service Valve - Suction See Panels - Miscellaneous 9 Service Valve - Liquid See Panels - Miscellaneous 17 Stk Condenser Coil AS AS AS AS AS Distributor - 3 way (3/4 in. to 3/8 in.) - w/o Header Tubes N/A N/A N/A Distributor - 4 way (3/4 in. to 3/8 in.) - w/o Header Tubes N/A N/A N/A N/A Distributor - 6 way (7/8 in. to 3/8 in.) - w/o Header Tubes N/A N/A N/A N/A Stk Filter Drier Stk High Pressure Control Stk Muffler Stk Reversing Valve - Before M4604 (018/024), Before M5104 ( ) Stk Reversing Valve - After M4604 (018/024), After M5104 ( ) Stk Solenoid Coil - Reversing Valve Before M4604 (018/024), Before M5104 ( ) Stk Solenoid Coil - Reversing Valve After M4604 (018/024), After M5104 ( ) Stk Strainer/Flowcheck Distributor Assembly w/o Piston Stk Piston (Factory Installed) Wiring Harness - Reversing Valve Charge Compensator N/A N/A Accumulator Stk TXV - Sporlan (See Note 1) N/A N/A N/A Stk TXV - Emerson (See Note 1) COIL GROUP 8 Service Valve - Suction See Panels - Miscellaneous 9 Service Valve - Liquid See Panels - Miscellaneous 17 Stk Condenser Coil AS AS AS AS Stk Filter Drier Stk High Pressure Control Stk Muffler N/A Stk Reversing Valve - Before M Stk Reversing Valve - After M Stk Solenoid Coil - Reversing Valve - Before M Stk Solenoid Coil - Reversing Valve - After M Stk Strainer/Flowcheck Distributor Assembly w/o Piston Stk Piston (Factory Installed) Wiring Harness - Reversing Valve Charge Compensator N/A N/A Accumulator Stk TXV - Sporlan (See Note 1) Stk TXV - Emerson (See Note 1) Page 6 of
7 COMPRESSOR GROUP Compressor ID: Stk Compressor S S S S 12 Stk,2 Capacitor - Compressor/Fan (See Note 2) Stk,2 Capacitor - Compressor/Fan (See Note 2) N/A N/A N/A N/A 13 Stk Start Relay Stk Start Capacitor COMPRESSOR GROUP Compressor ID: Stk Compressor S S Stk Capacitor - Compressor/Fan Stk Start Relay Stk Start Capacitor VARIATIONS ALL ACCESSORIES Low Ambient Control RXPZ-C01 Compressor Time Delay Control RXMD-B01 Heat Pump Monitor RXPM-B01 Outdoor Thermostat (One Thermostat w/box) RXPT-A01 Outdoor Thermostat (One Thermostat w/o box) RXPT-A02 Outdoor Thermostat (One w/heat Relay and box) RXPT-A03 Outdoor Thermostat (Two Thermostats w/heat and box) RXPT-A04 Blower Time Delay Control RXMD-C02 Page 7 of
8 Exploded View Page 8 of
9 Control Box Assembly Page 9 of
10 NOTES Stk It is recommended that stock be maintained for this part. N/A Not Applicable 1 The Sporlan and Emerson valves specified for this unit may be interchanged in service. The valves are interchangeable for this specific model only. 2 Later replacement Fan Motors require different capacitance values than those originally applied. Verify Fan Motor capacitance requirement before ordering. DISCLAIMER: This document is intended to provide general replacement parts information to aid qualified service personnel in the repair of these models. The complete Model and Serial Number of the unit under repair should be specified when selecting and ordering replacement parts. Specifications and illustrations are subject to change without notice. Document supersedes all previous parts lists for these models. See for the latest revision of this document. The manufacturer assumes no obligation for errors or omissions. Service personnel must verify the proper and safe operation of equipment after the replacement of any original components. P.O. Box Fort Smith, AR
RPLA. Heat Pumps. Parts List 19-July-2011
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................
More informationRPMD. Heat Pumps. Parts List 02-October-2017
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of ontents Model Explanation...................................................................................................................
More informationRPKA. Heat Pumps. Parts List 07-May-2014
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................................................................
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps - Commercial Table of Contents Model Explanation...................................................................................................................
More informationUPNE. Heat Pumps. Parts List 19-July-2011
Parts List 19-uly-2011 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-.pdf for the current revision. Heat Pumps Table of ontents Model Explanation...................................................................
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. ondensing Units Table of ontents Model Explanation...................................................................
More informationGEN20AD-GEN20AL-GEN18AN
AD-- Parts List 02-August-16 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-ad--.pdf for the current revision. Standby Generators Table of Contents
More informationMHS BY(Y)
-(Y) Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807--(Y) Table
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz. Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239
More informationNordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units)
IMI CORNELIUS INC. www.cornelius.com Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units) Publication Number: 631806058 Revision Date: October 13, 2009 Revision: E Visit the
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz. Units Date 1/09 Table Of Contents This parts list contains
More informationMAINLINE MLA14 AIR CONDITIONERS
FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured
More informationMHS BY(D)
003-010() Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807-003-010()
More information4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP
4HP15 PRODUCT SPECIFICATIONS 15 SPLIT SYSTEM HEAT PUMP FORM NO. 4HP15-100 (12/2017) FEATURES AND BENEFITS R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for
More informationDEALER DIRECT WARRANTY MANUAL
DEALER DIRECT WARRANTY MANUAL Table of Contents Extended Warranty Purchase Process... 3 Extended Warranty Order Form Instruction Guide... 4 Extended Warranty Order Form... 5 Warranty Regisration Process...
More informationThis parts list is current as of the above revision date. See for the current revision.
RK arts ist This parts list is current as of the above revision date. See http://www.rheempartslists.net/.pdf for the current revision. ackage ir Conditioners - Commercial Table of Contents odel Explanation...................................................................................................................
More informationProduct Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)
CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE Product Data (3619, 4823, 6025) A06009 A07904 The CAPMP and CARMP evaporator coils incorporate proven standards for reliable system operation and
More informationAE R1 February 2015
February 2015 CoreSense Diagnostics for Copeland Scroll UltraTech Air Conditioning Compressors TABLE OF CONTENTS Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to
More informationMODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners
15.5 MODEL: SA13 Air Conditioners FORM NO. ASC-221 REV. 1 Sure Comfort SA13 Air Conditioners Efficiencies 13-15.5 S/11.5-13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5
More informationAIR CONDITIONERS WA14**W SERIES
FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.
FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationRuud Achiever Series Heat Pump
Heat Pumps Ruud Achiever Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationAIR CONDITIONERS WA14 SERIES
FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationRuud Achiever Series Heat Pump
Heat Pumps Ruud Achiever Series Heat Pump RP14**F Series Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper
More informationModel 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.
EVAPORATOR COILS A COIL UNCASED R 22 or R 410A SYSTEMS 1 5 Tons WEAU Certification applies only when the complete system is listed with ARI ISO 9001:2000 REGISTERED R 410A R 22 Size Shipping Weight Size
More informationProduct Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES
CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.
FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7
More informationField Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.
Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.
More informationAE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions
AE19-1132 R8 December 2004 Reformatted November 2010 Copelametic Two-Stage Compressors Application and Service Instructions The Copeland two stage compressors have been developed to efficiently achieve
More informationTWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3
TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: up to 14 SEER/11.5 EER/8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing
More informationInstallation Instructions
Low -Ambient Pressure Switch 0201R22 0301410 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,
More informationInstallation Instructions
32LT900301 32LT900611 32LT901247 32LT901647 SMALL ROOFTOP S ACCESSORY MOTORMASTERR I HEAD PRESSURE CONTROLLER 3to10TONS Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 PACKAGE USAGE-
More informationThis parts list is current as of the above revision date. See for the current revision.
RKK Parts ist This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-rkk.pdf for the current revision. Package Gas-Electric - Commercial Table of Contents
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14 SEER/11.5 EER 8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationInstallation Instructions
Installation Instructions Low-Ambient Pressure Switch KSALA0201R22 KSALA0301410 NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,
More informationProduct Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP
CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil Cased and Uncased Upflow, Downflow Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.
FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to
More informationSupersedes: RP1(495) Form RP1 (1102)
RENEWAL PARTS CENTRIFUGAL LIQUID CHILLERS Supersedes: 0.9-RP(9) Form 0.9-RP (0) UNIT COMPONENTS MODEL YK (STYLES A & B) WITH MICROCOMPUTER CONTROL CENTER PART #3-000-00 FOR ELECTRO-MECHANICAL STARTER &
More informationSpare parts list ( ) Spare parts list HDS 990
Spare parts list (5.952-855.0) Spare parts list HDS 990 13.10.2014 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 990 (5.952-855.0)... 6 10 Individual parts... 7 49 Spare
More informationMAINLINE MLP14**A HEAT PUMPS
FORM NO. PML-806 REV. 2 Supersedes Form No. PTZ-789 MAINLINE HEAT PUMPS Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to
More informationK Page 1 of 48 Air Intake - Pg. 17
K532-53168 Page 1 of 48 Air Intake - Pg. 17 Ref # Part Number Qty Description 24 25 041 06-S 1 Gasket, elbow 25 48 054 09 1 Elbow, air cleaner Discontinued not available at Kohler Co. 35 277116-S 1 Brace,
More informationGM Series Dual-Block Multi-Function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series
More informationRheem Classic Series Two Stage Heat Pump
Heat Pumps Rheem Classic Series Two Stage Heat Pump Efficiencies: 15-16 SEER/11.5-13 EER Nominal Sizes 2, 3, 4 and 5 Ton [7.03, 10.6, 14.06 and 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7
More informationLENNOX SLP98UHV DIAGNOSTIC CODES
Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second
More informationAC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight
Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this
More informationREPLACEMENT PARTS LIST FOR MODELS: Consult factory for all other models
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 134 Louisville,
More informationELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATIONS AIR CONDITIONERS EL16XC1 ELITE Series R-410A Bulletin 210758 November 2017 Supersedes August 2017 SEER up to 17.90 1.5 to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh MODEL NUMBER
More informationMPS-003AG-005AG
003- Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807-003- Table
More informationRAYPAK ILLUSTRATED PARTS LIST
COMMERCIAL MODELS: XFYRE 300 THROUGH 850 CATALOG NO. 9300.79 Effective: 10-05-18 Replaces: 09-15-17 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 300, 400, 500, 700 & 850 MODEL TYPES: MODULATING CONDENSING
More informationFSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities
TECHNICAL SPECIFICATIONS FSH1BG Series FEATURES and BENEFITS Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities 1 The iq Drive heat pump system features modulating compressor
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS C3, C4, C5 Uncased Indoor Coils (RepLcoil) 2 3/8" 1 3/8" 12 1/8" H 14 1/2" 19 1/2" 2 1/2" W "A" Coil Features Anteater Coil Technology: The Anteater TM coil is made with Uniguard
More informationRefrigeration Scroll For Parallel Applications
Refrigeration Scroll For Parallel Applications Application Guideline 1 Scroll Compressors in Parallel for Refrigeration Applications 1. Introduction The concept of parallel operation for refrigeration
More informationService Parts Manual Drawer Microwave Models: MWD24-2 & MWD30-2
Service Parts Manual 28 14 40 49 68 29 73 5 11 55 38 75 56 4 44 8 7 45 1 52 2 22 10 46 50 71 25 26 62 15 27 3 24 48 9 39 57 13 63 39 74 36 64 51 53 50 6 35 66 42 70 21 18 37 55 16 17 76 60 33 67 19 54
More informationCROT-6 CROT-10 CRO-4. for Compressor Overload Protection
May 2010 / RACE Catalogue 90-10 UK for Compressor Overload Protection CROT-6 Listed and y Certified 400 psig Maximum Rated Pressure CROT-10 Listed and Certified 400 psig Maximum Rated Pressure CRO-4 Recognized
More informationApplication Engineering Bulletin AE-1301 Issued June, Copeland APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A
4-1301 Application Engineering Bulletin AE-1301 Issued June, 1996 APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A Introduction The new model family of "ZP" compressors is designed for
More informationApplication Guideline. R410A Air Conditioning Scroll
Application Guideline R410A Air Conditioning Scroll Contents 1 Introduction 2 Nomenclature 3 How a Scroll Works 4 Application Considerations 4.1 Accumulators 4.2.1 Crankcase Heaters Single Phase 4.2.2
More informationAE R4. December Copeland Scroll Compressors for CO 2 Subcritical Refrigeration (R-744)
December 2017 Copeland Scroll Compressors for CO 2 Subcritical Refrigeration (R-744) TABLE OF CONTENTS Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of Electrical
More informationGuideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society
Guideline No.M-05(201510) M-05 AIR COMPRESSOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable technical requirements
More informationModel Series 62 Constant Differential Relay
Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant
More informationVARIABLE SPEED AIR CONDITIONERS
FORM NO. AFJ-224 Supersedes Form No. AFJ-222 VARIABLE SPEED AIR CONDITIONERS FO*20C SERIES Efficiencies up to 20 SEER/13 EER Nominal Sizes 2, 3, 4 & 5 Ton [7.03, 10.6, 14.06 & 17.6 kw] Cooling Capacities
More informationUser s Information Manual
48HC with EnergyX R System Factory Installed Energy Recovery Single---Package Rooftop Unit (RTU) Gas Heating/Electric Cooling Units 15 to 25 Nominal Tons with Puronr (R---410A) Refrigerant User s Information
More informationTECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH
TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!
More informationRG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free
TM Refrigerant Recovery Machine RG6000 1 Operating Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Safety Precautions WARNING
More information36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS
36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING
More informationREPLACEMENT PARTS LIST FOR GRINDER MODELS:
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. 50/0Hz FM2_Ec 1117 Supersedes 091 MAIL TO: P.O. BOX 17 Louisville,
More information4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS
PRODUCT SPECIFICATIONS 16 S SPLIT SYSTEM ENHANCED AIR CONDITIONING FORM NO. -100 (06/2014) DESIGN Designed for ambients up to 125 F COMPONENTS Service valves positioned for quick installation and easy
More informationOC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)
by Supera Anesthesia Innovations USER'S GUIDE OC4000 OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY I O : ON (power switched on) : OFF (power switched off) : Class II protection : Do not expose to open flames
More informationFAULT CODE TROUBLESHOOTING INDEX
FAULT CODE TROUBLESHOOTING INDEX 1. Display indicates Change Filters 2. Display indicates Drip Tray Full Continuous Alarm will Sound 3. Display indicates Cold Fault 4. Display indicates Hot Fault 5. Display
More informationMAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump
A. PARTS MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump Assembly & Operating Instructions Parts for liquid chlorine pump head 1pc. 1/4 poly delivery tubing, 4 meters 1pc. drum
More informationSpare parts list. ( ) Spare parts list HD 3.0/20 C Ea
Spare parts list (5.972-551.0) Spare parts list HD 3.0/20 C Ea 20.04.2016 www.kaercher.com EN Table of contents Order instructions Spare parts list HD 3.0/20 C Ea (5.972-551.0) 10 Housing 20 Pump set 21
More informationEvaporator (DX) Freon Applications 1 12 Tons MHF
Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client
More informationSpare parts list ( ) Spare parts list HD 1090 WS *
Spare parts list (5.955-706.0) Spare parts list HD 1090 WS * 26.01.2015 www.kaercher.com EN Table of contents Spare parts list HD 1090 WS * (5.955-706.0)... 6 10 Individual parts... 7 11 Individual parts...
More informationThis parts list is current as of the above revision date. See for the current revision.
RKN Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/.pdf for the current revision. Package Gas-Electric - ommercial Table of ontents Model Explanation...................................................................................................................
More informationSpare parts list. ( ) Spare parts list HD 3.0/20 C Ea
Spare parts list (5.972-551.0) Spare parts list HD 3.0/20 C Ea 24.06.2016 www.kaercher.com EN Page 2 / 51 Page 3 / 51 Page 4 / 51 Table of contents Order instructions Spare parts list HD 3.0/20 C Ea (5.972-551.0)
More information14. Exploded View. Page 68
14. Exploded View Page 68 15. View of housing Page 69 11. Spare Parts HY05 HY13 55 E-2124010 Keys for safety, set=2pc. 54 E-2124012 Safety lock incl. 2 keys 1 B-3204031 1 B-2204101 1 B-2204111 1 2 B-2204105
More informationCopeland Discus with CoreSense Diagnostics January 2011
Copeland Discus with CoreSense Diagnostics January 2011 Slide 1 1/27/2011 5:48 PM Discus with CoreSense Diagnostics Case Studies Supermarket In Columbus, Ohio Saves $4,500 With Discus with CoreSense Diagnostics
More informationRIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]
RIX COMPRESSORS MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230 November 21, 2002 APPLICABILITY [ A] INTRODUCTION Safety This electromechanical equipment is designed to produce high pressure gas.
More informationSTANDARD PROCEDURE FOR THE REPLACEMENT OF COMPONENTS IN A SEALED REFRIGERANT SYSTEM (Compressor Failure and Replacement)
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 STANDARD PROCEDURE FOR THE REPLACEMENT OF COMPONENTS IN A SEALED REFRIGERANT SYSTEM (Compressor Failure and Replacement)
More informationSpare parts list ( ) Spare parts list HDS 700 B
Spare parts list (5.955-875.0) Spare parts list HDS 700 B 02.09.2013 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 700 B (5.955-875.0)... 6 10 Individual parts... 7 11
More informationSoft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II
Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II Stephen Li Daikin / Goodman Manufacturing Jan. 2016 1 2 Test objectives See the impact of R-32 on air
More informationUniversal Valve Company Inc
Universal Valve Company Inc 800-223-0741 www.universalvalve.com 1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Free Air Universal
More informationSpare parts list ( ) Spare parts list HDS 5.0/30 S-4 Eh
Spare parts list (5.970-508.0) Spare parts list HDS 5.0/30 S-4 Eh 21.05.2012 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 5.0/30 S-4 Eh (5.970-508.0)... 6 10 Housing
More informationFX134, FX1234, FX3030 Problem and Solutions
FX134, FX1234, FX3030 Problem and Solutions Unit Will Not Power Up Turn the power switch on. The unit LCD will display revision program and filter life within 3 to 5 seconds after turning on unit. If this
More informationUniversal Valve Company Inc
1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Universal Air Towers Please read closely to identify the components that are
More informationCrest Heating Boilers FBN(L) Series &
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 Series 100-101 & 110-111
More informationUNIVERSAL GAS FRYER Instruction Manual Model #8065NS
Part No. 88847 Revised: August 2004 UNIVERSAL GAS FRYER Instruction Manual Model #8065NS Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS OPERATING INSTRUCTIONS UNPACKING AND ASSEMBLY After unpacking
More informationMD R a n g e O p e r a t o r s H a n d b o o k
MD R a n g e O p e r a t o r s H a n d b o o k Covering Models:- MD35/20 MD75/80 MD75/0 MD75/0V MD75/250 MD75/250V MD0/500 MD225/1000 BAMBI AIR COMPRESSORS LTD 2 Thimble Mill Lane Heartlands Birmingham
More informationMODELS YLAA YLAA0175 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A
AIR-COOLED SCROLL CHILLERS RENEWAL PARTS Supersedes: 50.72-RP (80) Form 50.72-RP () MODELS YLAA0070 - YLAA075 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A GS5608 R-0A 70-75 TON 60 Hz Issue Date: January,
More informationInstallation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)
IB-77 Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger) These installation, operation and technical instructions should be used by experienced personnel as a
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More information11. Spare Parts. applications since applications since
2 8 2 6 20 2 8 0 5 6 8 9 2 2 25 7 8 9 5 0 2 2 7 . Spare Parts * C0 C02 C06 C0 C7 C C0 C5 C58 Article No. Description B-26 B-2009 Steam generation Steam cylinder CY DN20 compl. with electrodes and hand
More information4SCU13 PRODUCT SPECIFICATIONS
4SCU PRODUCT SPECIFICATIONS PHASE SPLIT SYSTEM AIR CONDITIONER FORM NO. 4SCULC-00 (0/07) coil ifice shipped with outdo unit f optimum efficiency and capacity Charged f 5 ft. of line set Trade available
More informationINSTALLATION GUIDE Gas Rangetops
INSTALLATION GUIDE Gas Rangetops Contents Wolf Gas Rangetops........................... 3 Safety Instructions............................ 4 Gas Rangetop Specifications.................... 5 Gas Rangetop
More informationSAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER
SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established
More information