MPS-003AG-005AG

Size: px
Start display at page:

Download "MPS-003AG-005AG"

Transcription

1 003- Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call or visit Form Number:

2 Table of ontents Model Explanation Page 3 Parts Numbers rawings/photographs Panels - Miscellaneous Page 4 Fan Group Page 5 ompressor Group Page 5 oil Parts Page 5 Electrical Group Page 6 Blower Group - irect rive Page 7 Blower Group - Belt rive Page 8 Gas ontrols Page 9 Heat Exchanger-Burner Group Page 10 Accessories Page 11 Orifice Selection hart Page 12 Exploded View Page 13 ut-away View Page 14 irect rive Parts Page 14 Belt rive Parts Page 15 Refrigeration Parts Page 16 ompressor and Pressure ontrols Page 16 Heat Exchanger Assembly Page 17 In-Shot Burner Assembly - Before F Page 17 One Piece Burner Assembly - After F Page 18 oil Assembly Page 19 ontrol Box Page 19 TXV Identification Guide Page 20 Notes Page 21 Page 2 of

3 MOEL NUMBER EXPLANATION M P S A G K 13 E AA A McQUAY PAKE SYSTEM 8 ELETRI GAS HEAT IGNITION E = ELETRI IGNITION - 1 STE VALVE 2 9 FATORY OPTIONS 3 VINTE AA = NO OPTIONS B = HAIL GUAR, LOW AMBIENT TIME ELAY, 4 HEAT ESIGNATION STAINLESS STEEL HEAT EXHANGER, G = NATURAL GAS HEATING HIGH AN LOW PRESSURE EB = B WITH ISONNET AN SERVIE 5 ELETRIAL ESIGNATION OUTLET = /3/60 = 460/3/60 10 EONOMIZER OPTION A = NO EONOMIZER 6 RIVE PAKE B = EONOMIZER K = IRET RIVE L = BELT RIVE M = BELT RIVE - HIGH STATI 7 HEATING APAITY (MBH) 08 = 80, = 100, = 120, = 135,000 SERIAL NUMBER EXPLANATION 1X A 1234 A A A A F GAS OE 6 HEAT EXHANGER A = T140 ALUMINIZE STEEL TUBULAR 2 BLOWER ONTROL BOAR B = 409 STAINLESS STEEL TUBULAR 3 OMPRESSOR IENTIFIATION NUMBER 7 TEHNOLOGY VARIATIONS A = INITIAL ESIGN 4 IGNITION EVIE 8 PROUTION LOATION 5 INUER BLOWER: A = AMETEK PLASTI HOUSING 9 WEEK B = EMERSON PLASTI HOUSING = EMERSON METAL HOUSING 10 YEAR = FASO METAL HOUSING 11 PROUTION NUMBER Page 3 of

4 MOEL No. Notes VINTE/HEAT ESIGNATION PANELS, MISELLANEOUS PARTS 1 BASE RAIL - SIE (2) AE AE AE BASE RAIL - ONENSER EN AE AE AE BASE RAIL - EVAPORATOR EN AE AE AE OUTOOR OIL BASE PAN AS B AS B AS B 5 INOOR OIL BASE PAN AS AS AS ONENSER BULKHEA - OES NOT INLUE LIMIT BAFFLE or TUBE SUPPORT ANGLES. AS AS AS LIMIT BAFFLE - ATTAHE TO ONENSER BULKHEA ("08, 012" Heat) AE N/A N/A LIMIT BAFFLE - ATTAHE TO ONENSER BULKHEA ("010" Heat) N/A AE AE LIMIT BAFFLE - ATTAHE TO ONENSER BULKHEA ("013" Heat) N/A AE AE TUBE SUPPORT ANGLE - ATTAHE TO THE ON. BULKHEA AE AE AE BLOWER BULKHEA - (OES NOT INLUE TUBE SUPPORT ANGLE, BLOWER EXTENSION OR INSULATION AS AS AS RETAINER) TUBE SUPPORT ANGLE - SMALL PIEE ATTAHE TO THE BLOWER BULKHEA - NOT PITURE AE AE AE BLOWER EXTENSION - FRONT AE AE AE BLOWER EXTENSION - BAK AE AE AE INSULATION RETAINER AE AE AE WIRE HASE INSUL ASSEMBLY AS AS AS ORNER POST (2) AS B AS B AS B 14 LOUVERE PANEL AS B AS B AS B 15 LOUVERE PANEL AS B AS B AS B 16 LOUVERE PANEL AS B AS B AS B 17 SUPPLY/RETURN PANELS (2) AS B AS B AS B 18 REAR PANEL - INLUES INSULATION AN FILLER PANEL AN STRIPPING AS B AS B AS B 19 FILLER PANEL - RETURN AIR AS B AS B AS B FILLER PANEL STRIPPING AE AE AE BLOWER/FILTER AESS PANELS (ORER 2 IF BOTH ARE NEEE) AS B AS B AS B 21 POST - LEFT EN AS B AS B AS B 22 FRONT PANEL AS B AS B AS B 23 VINYL GROMMET HEATING OMPARTMENT AESS PANEL AS B AS B AS B 25 FLUE HOO AS AS AS FLUE HOO GASKET MOUNTING PANEL EXT. ISONNET AE AE AE OMPRESSOR AESS PANEL AS B AS B AS B 27 POWER ENTRY PANEL AS B AS B AS B 28 FRONT POST AS B AS B AS B 29 INOOR OIL TOP PANEL ASSEMBLY AS B AS B AS B 30 ONENSER TOP PANEL ASSEMBLY AS B AS B AS B 32 WIRE GRILLE ONTROL BOX - LESS OMPONENTS AS AS AS Page 4 of

5 MOEL No. Notes VINTE/HEAT ESIGNATION ELETRIAL ESIGNATION FAN GROUP 35 Stk ONENSER FAN MOTOR Stk ONENSER FAN BLAE Stk FAN APAITOR APAITOR AAPTER PLATE AE AE AE AE MOEL No. Notes VINTE/HEAT ESIGNATION ELETRIAL ESIGNATION FAN GROUP 35 Stk ONENSER FAN MOTOR Stk ONENSER FAN BLAE Stk FAN APAITOR APAITOR AAPTER PLATE AE AE MOEL No. Notes VINTE/HEAT ESIGNATION ELETRIAL ESIGNATION OMPRESSOR OMPRESSOR I: Stk OMPRESSOR Stk OMPRESSOR HARNESS - MOLE PLUG MOEL No. Notes VINTE/HEAT ESIGNATION ELETRIAL ESIGNATION OMPRESSOR OMPRESSOR I: Stk OMPRESSOR Stk OMPRESSOR HARNESS - MOLE PLUG MOEL No. Notes VINTE/HEAT ESIGNATION OIL GROUP 6 FILTER KEEPER AE AE AE Stk EVAPORATOR OIL AS AS AS Important Note: ifferent manufacturers of TXV were used on this unit, and the exact part number must be used when making repair. To obtain the correct part number of the TXV either: (1) Provide the part number of TXV assembly by examining unit, or (2) Provide unit model number and TXV manufacturer. (See attached TXV identification guide for assistance.) 78 Stk TXV - SPORLAN Stk TXV - EMERSON STRAINER TOP AIR STOP AE AE AE TOP OIL SUPPORT AE AE AE FILTER HANNELS AE AE AE INOOR OIL RAIN PAN Stk ONENSER OIL AS AS AS FILTER - ISPOSABLE (2) Page 5 of

6 MOEL No. Notes VINTE/HEAT ESIGNATION ELETRIAL ESIGNATION RIVE PAKE 003 K 003 K 004 K 004 K ELETRI GROUP ONTROL BOX OMPONENTS: 37 Stk INTEGRATE FURNAE ONTROL OMPRESSOR TIME ELAY RELAY SEE AESSORIES 40 Stk OMPRESSOR ONTATOR Stk TRANSFORMER Stk AUXILIARY LIMIT - Blower Extension Stk PRESSURE SWITH Stk INUER BLOWER MOTOR - Including Gasket Stk INUER BLOWER MOTOR GASKET LOW PRESSURE ONTROL SEE AESSORIES 51 HIGH PRESSURE ONTROL SEE AESSORIES 52 FREEZE STAT SEE AESSORIES MOEL No. Notes VINTE/HEAT ESIGNATION ELETRIAL ESIGNATION RIVE PAKE M L M ELETRI GROUP ONTROL BOX OMPONENTS: 37 Stk INTEGRATE FURNAE ONTROL Stk BELT RIVE ONTATOR OMPRESSOR TIME ELAY RELAY SEE AESSORIES 40 Stk OMPRESSOR ONTATOR Stk TRANSFORMER Stk AUXILIARY LIMIT - Blower Extension Stk PRESSURE SWITH Stk INUER BLOWER MOTOR - Including Gasket Stk INUER BLOWER MOTOR GASKET LOW PRESSURE ONTROL SEE AESSORIES 51 HIGH PRESSURE ONTROL SEE AESSORIES 52 FREEZE STAT SEE AESSORIES Page 6 of

7 MOEL No. Notes VINTE/HEAT ESIGNATION ELETRIAL ESIGNATION RIVE PAKE 003 K 003 K 004 K 004 K BLOWER GROUP - IRET RIVE 53 Stk BLOWER ASSEMBLY AS AS AS AS HOUSING AS AS AS AS Stk WHEEL UT-OFF TABULATION AE AE AE AE Stk MOTOR Stk MOTOR APAITOR MOTOR BAN MOTOR MOUNTING ARM (3) BLOWER SUPPORT AE AE AE AE Page 7 of

8 MOEL No. Notes VINTE/HEAT ESIGNATION ELETRIAL ESIGNATION RIVE PAKE M L M BLOWER GROUP - BELT RIVE 62 Stk BLOWER ASSEMBLY (Less Motor, Belt and Sheaves): AS AS AS HOUSING AS AS AS BEARING FRAME TRI-ARM (3) Stk BALL BEARING and USHION (2) Stk 3/4 in. BLOWER SHAFT Stk FIXE PITH SHEAVE BLOWER SUPPORT - LEFT (Housing to Evaporator oil) AE AE AE Stk WHEEL UT-OFF TABULATION AE AE AE MOEL No. Notes VINTE/HEAT ESIGNATION ELETRIAL ESIGNATION RIVE PAKE M L M MOTOR, BELT AN VARIABLE PITH SHEAVE FOR BLOWER ASSEMBLY BELT RIVE 74 Stk MOTOR Stk VARIABLE PITH SHEAVE Stk BELT MOEL No. Notes VINTE/HEAT ESIGNATION ELETRIAL ESIGNATION RIVE PAKE M L M MOTOR MOUNTING MOTOR MOUNTING: 71 BLOWER BRAKET AE AE AE BLOWER BRAKET - RIVE SIE AE AE AE a GROMMET MOTOR MOUNT ASSEMBLY AS AS AS Page 8 of

9 MOEL No. Notes VINTE/HEAT ESIGNATION HEATING APAITY 08 IRET SPARK IGNITION - HONEYWELL GAS ONTROL SERIAL ONTROL OES - 2G Stk GAS VALVE - VR8205S STREET ELBOW NIPPLE Stk LP ONVERSION KIT EP-85H EP-85H EP-85H EP-85H 104 BURNER ORIFIE - LP (See onversion Kit Index) MOEL No. Notes VINTE/HEAT ESIGNATION HEATING APAITY IRET SPARK IGNITION - HONEYWELL GAS ONTROL SERIAL ONTROL OES - 1R 107 Stk GAS VALVE -VR8205M STREET ELBOW NIPPLE Stk LP ONVERSION KIT EP-85H EP-85H EP-85H EP-85H 104 BURNER ORIFIE - LP (See onversion Kit Index) MOEL No. Notes VINTE/HEAT ESIGNATION HEATING APAITY IRET SPARK IGNITION - WHITE-ROGERS GAS ONTROL SERIAL ONTROL OES - 2A 107 Stk GAS VALVE - WR 36E STREET ELBOW Stk LP ONVERSION KIT EP-84W EP-84W EP-84W EP-84W 104 BURNER ORIFIE - LP (See onversion Kit Index) MOEL No. Notes VINTE/HEAT ESIGNATION HEATING APAITY IRET SPARK IGNITION - WHITE-ROGERS GAS ONTROL SERIAL ONTROL OES - 1X 107 Stk GAS VALVE - WR 36E STREET ELBOW Stk LP ONVERSION KIT EP-84W EP-84W EP-84W EP-84W 104 BURNER ORIFIE - LP (See onversion Kit Index) MOEL No. Notes VINTE/HEAT ESIGNATION HEATING APAITY IRET SPARK IGNITION - WHITE-ROGERS GAS ONTROL SERIAL ONTROL OES - 2X 107 Stk GAS VALVE - WR 36J STREET ELBOW Stk LP ONVERSION KIT EP-84W 104 BURNER ORIFIE - LP (See onversion Kit Index) 10 Page 9 of

10 MOEL No. Notes VINTE/HEAT ESIGNATION HEATING APAITY HEAT EXHANGER, BURNER/MANIFOL 45 Stk MAIN LIMIT - (ON. BULKHEA): MAIN LIMIT SHIEL AS AS AS AS Stk HEAT EXHANGER - INLUES ENTER PANEL AS AS AS AS IVIER PLATE GASKET IVIER PLATE AE AE AE AE OLLETOR BOX GASKET OLLETOR BOX OVER AE AE AE AE FLUE UT FLUE UT GASKET BURNER SHEIL AE AE AE AE LIMIT - MANUAL RESET (BURNER OMPARTMENT) - Burner Tube esign (See Note Stk,1 1) (1) (2) (2) (2) 97 LIMIT - MANUAL RESET (BURNER OMPARTMENT) - Single Piece Burner esign Stk,1 (See Note 1) (1) (2) (2) (2) 98 BURNER OMPARTMENT FLOOR AE AE AE AE MOEL No. Notes VINTE/HEAT ESIGNATION HEATING APAITY BURNER ASSEMBLY 99 BURNER TUBE w/shiel - Burner Tube esign (See Note 1) (4) (5) (6) (6) 99 BURNER ASSEMBLY - Single Piece Burner esign (See Note 1) AS AS AS AS a BUSHING (See Note 1) BURNER SUPPORT - (HOLES THE BURNERS BETWEEN THE BURNER SUPPORTS BRAKETS) - Burner Tube esign (See Note 1) AE AE AE AE BURNER SUPPORT - (HOLES THE BURNERS BETWEEN THE BURNER SUPPORTS BRAKETS) - Single Piece Burner esign (See Note 1) AE AE AE AE BURNER SUPPORT BRAKET (2) - Burner Tube esign (See Note 1) AE AE AE AE BURNER SUPPORT BRAKET (2) - Single Piece Burner esign (See Note 1) AE AE AE AE Stk MANIFOL ASSEMBLY - Less Orfices or Plugs SQUARE HEA PLUG - (USE ON MANIFOL TO PLUG EXTRA HOLES) (3) (2) (1) (1) 104 BURNER ORIFIE - NATURAL GAS: See Orifice Selection hart 104 BURNER ORIFIE - LP: See Orifice Selection hart 104 NUMBER OF ORIFIES (4) (5) (6) (6) 105 Stk FLAME SENSOR Stk IGNITION ELETROE and ABLE Page 10 of

11 MOEL No. Notes VINTE/HEAT ESIGNATION ELETRIAL ESIGNATION POWER EXHAUST POWER EXHAUST MXRX-BGF04 MXRX-BGF04 MOEL No. Notes VINTE/HEAT ESIGNATION HEATING APAITY FRESH AIR AMPER MANUAL FRESH AIR AMPER MXRF-FBA1 MOTORIZE FRESH AIR AMPER MXRF-FBB1 ALL MOEL No. Notes VINTE/HEAT ESIGNATION HEATING APAITY AESSORY OPTIONS LOW AMBIENT ONTROL KIT RXRZ-A18 TIME ELAY ONTROL KIT RXM-B01 LOW PRESSURE ONTROL KIT RXA-A02 HIGH PRESSURE ONTROL KIT RXAB-A02 FREEZE STAT RXRX-AM01 ISONNET SWITH ALL MOEL No. Notes VINTE/HEAT ESIGNATION EONOMIZERS See EONOMIZER - SINGLE ENTHALPY (ONVERTIBLE AIRFLOW) Note MXR-MEM3 UAL ENTHALPY UPGRAE KIT RXRX-AV02 O2 SENSOR RXRX-AR02 Note: For replacement parts for Economizer, refer to their individual parts lists. ALL Page 11 of

12 PAKE EQUIPMENT - ORIFIE SELETION HART - NATURAL GAS AUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation: 1) Furnace Input Rating (BTU/HR) 2) Number of Burners 2) Altitude (ft.) For detailed information and instructions for Orifice selection, contact McQuay Parts and see the latest edition of the National Fuel Gas ode Handbook, or the National Standard of anada, Natural Gas and Propane Installation ode, AN B AUTION: This information is provided for replacement purposes only. onversion for operation at High Altitude must be done using the kit specified on the product specification sheet for the unit. NOTE: This Orifice sizing chart is based on a Natural Gas heating value of 1075 BTU/cu. ft and a pressure setting of 3.5 in. water column. NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of ft. anadian High Elevation (ft.) Furnace Number Altitude erated ountry Input of Input Rating (BTU/HR) Burners (BTU/HR) U.S. U.S. U.S. U.S. anada anada 40,000 36, ,000 54, ,000 N/A N/A 80,000 72, ,000 N/A N/A 100,000 90, , , , , , , ,000 N/A N/A 210,000 N/A N/A 210,000 N/A N/A 225, , , , , , ,000 N/A N/A 290,000 N/A N/A 300, , ,000 N/A N/A 350, , , , PAKE EQUIPMENT - ORIFIE SELETION HART - LP AUTION: Selection of the correct LP Orifice requires the following information for the specific installation: 1) Furnace Input Rating (BTU/HR) 2) Number of Burners 2) Altitude (ft.) For detailed information and instructions for Orifice selection, contact McQuay Parts and see the latest edition of the National Fuel Gas ode Handbook, or the National Standard of anada, Natural Gas and Propane Installation ode, AN B AUTION: This information is provided for replacement purposes only. onversion to LP or for operation at High Altitude should be done using the kit(s) specified on the product specification sheet for the unit. NOTE: This Orifice sizing chart is developed using the specified pressure setting of 10 in. water column instead of the 11.0 in water column used by the NFG and ANB NOTE: Orifices supplied in the LP onversion Kit are calculated and sized based on a heating value of 2500 BTU/cu. ft. and an elevation of ft. anadian High Elevation (ft.) Furnace Number Altitude erated ountry Input of Input Rating (BTU/HR) Burners (BTU/HR) U.S. U.S. U.S. U.S. anada anada 40,000 36, ,000 54, ,000 N/A N/A 80,000 72, ,000 N/A N/A 100,000 90, , , , , , , ,000 N/A N/A 210,000 N/A N/A 210,000 N/A N/A 225, , , , , , ,000 N/A N/A 290,000 N/A N/A 300, , ,000 N/A N/A 350, , , , Page 12 of

13 Exploded View Page 13 of

14 ut-away View irect rive Parts Page 14 of

15 Belt rive Parts Page 15 of

16 Refrigeration Parts ompressor and Pressure ontrols Page 16 of

17 Heat Exchanger Assembly In-Shot Burner Assembly - Before F4708 Page 17 of

18 One Piece Burner Assembly - After F4708 Page 18 of

19 oil Assembly ontrol Box Page 19 of

20 TXV Identification Guide Page 20 of

21 NOTES Stk It is recommended that stock be maintained for this part. N/A Not Applicable 1 On or about 11/22/08 (ate ode 4708), the Burner Assemblies were changed from a multiple (individual) tube burner design to a single plate (integral) burner design. heck unit for appropriate burner assembly type before ordering replacement parts Industrial Park Blvd., P.O. Box 1551 Minneapolis, MN (763)

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. RKN Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/.pdf for the current revision. Package Gas-Electric - ommercial Table of ontents Model Explanation...................................................................................................................

More information

MHS BY(Y)

MHS BY(Y) -(Y) Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807--(Y) Table

More information

MHS BY(D)

MHS BY(D) 003-010() Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807-003-010()

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. ondensing Units Table of ontents Model Explanation...................................................................

More information

UPNE. Heat Pumps. Parts List 19-July-2011

UPNE. Heat Pumps. Parts List 19-July-2011 Parts List 19-uly-2011 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-.pdf for the current revision. Heat Pumps Table of ontents Model Explanation...................................................................

More information

RPMD. Heat Pumps. Parts List 02-October-2017

RPMD. Heat Pumps. Parts List 02-October-2017 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of ontents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. RKKB Parts ist This parts list is current as of the above revision date. See http://www.rheempartslists.net/.pdf for the current revision. Package Gas-Electric - ommercial Table of ontents odel Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps - Commercial Table of Contents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. RKK Parts ist This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-rkk.pdf for the current revision. Package Gas-Electric - Commercial Table of Contents

More information

RPNK. Heat Pumps. Parts List 25-July-2011

RPNK. Heat Pumps. Parts List 25-July-2011 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. RK arts ist This parts list is current as of the above revision date. See http://www.rheempartslists.net/.pdf for the current revision. ackage ir Conditioners - Commercial Table of Contents odel Explanation...................................................................................................................

More information

RPLA. Heat Pumps. Parts List 19-July-2011

RPLA. Heat Pumps. Parts List 19-July-2011 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................

More information

RPKA. Heat Pumps. Parts List 07-May-2014

RPKA. Heat Pumps. Parts List 07-May-2014 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................................................................

More information

Installation Instructions

Installation Instructions 48011HW NATURAL GAS TO PROPANE CONVERSION KIT 58HDX, 359AAV, PG9YAB, PG9YAA Installation Instructions SAFETY REQUIREMENTS Installing and servicing heating equipment can be hazardous due to gas and electrical

More information

Installation Instructions

Installation Instructions Low -Ambient Pressure Switch 0201R22 0301410 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,

More information

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel primary heat exchanger with crimped non-welded construction Stainless steel

More information

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel tapered design primary heat exchanger with crimped construction for long

More information

Crest Heating Boilers FBN(L) Series &

Crest Heating Boilers FBN(L) Series & Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 Series 100-101 & 110-111

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT ALPKT57- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... Table of Contents INSTALLATION

More information

Installation Instructions

Installation Instructions LP and High Altitude LP Gas Conversion Kit For United States Installations Installation Instructions For Model Series *G6/PGF1 Furnaces, *L1/PGC1 Furnaces, and *R4/PPG1 Gas/Electric Appliances using Honeywell

More information

Installation Instructions

Installation Instructions Installation Instructions Low-Ambient Pressure Switch KSALA0201R22 KSALA0301410 NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,

More information

GEN20AD-GEN20AL-GEN18AN

GEN20AD-GEN20AL-GEN18AN AD-- Parts List 02-August-16 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-ad--.pdf for the current revision. Standby Generators Table of Contents

More information

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS Part No. 88847 Revised: August 2004 UNIVERSAL GAS FRYER Instruction Manual Model #8065NS Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS OPERATING INSTRUCTIONS UNPACKING AND ASSEMBLY After unpacking

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0501 FOR USE WITH 95% MODELS: TG9S, GG9S (130,000 BTU ONLY) FOR USE WITH 80% MODELS: TG(8,L)S, GG(8,L)S (130,000

More information

Installation Instructions For Natural Gas Conversion

Installation Instructions For Natural Gas Conversion Installation Instructions For Natural Gas Conversion (Kit Part No. 1175405) This kit is designed to convert PGX4 and PX4 Two -Stage Gas units for use with Natural Gas. Table 1 Heating Value at Altitude

More information

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS Installation Instructions For Model Series *G7/*GC2 Furnaces and Appliances Using Honeywell Gas Valves. BEFORE THE CONVERSION

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS 1NP0680 - PROPANE CONVERSION FOR USE WITH MODELS: PM8, PC8, PM9, PC9, FL9M, FL9C, FC9M, FC9C This conversion kit is to be installed by a qualified service agency

More information

Rheem Spare Parts Manual Commercial gas model A Exterior 265L

Rheem Spare Parts Manual Commercial gas model A Exterior 265L Commercial gas model A631265 Exterior 265L 1 2 36 3 6 14 11 31 7 40 8 9 10 14 22 23 25 11 16 24 7 12 13 9 20 21 19 17 18 37 38 39 34 35 26 4 5 32 30 39 29 38 27 33 37 28 Commercial gas model A631265 Exterior

More information

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas Installation Instructions For Propane Gas Conversion (Kit Part No. 1173859) This kit is designed for conversion to Propane Gas Table 1 LP Gas Orifice Kits and Sizes Elevation Above Sea Level 0 to 2000

More information

K Page 1 of 48 Air Intake - Pg. 17

K Page 1 of 48 Air Intake - Pg. 17 K532-53168 Page 1 of 48 Air Intake - Pg. 17 Ref # Part Number Qty Description 24 25 041 06-S 1 Gasket, elbow 25 48 054 09 1 Elbow, air cleaner Discontinued not available at Kohler Co. 35 277116-S 1 Brace,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Propane Gas Conversion Kit WGCK-1 Instructions for 0-6,000 Feet Elevation Installations This propane gas conversion kit is to be used only when converting the following furnace

More information

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction. ACCESSORY KIT INSTALLATION INSTRUCTIONS HIGH ALTITUDE APPLICATION CONVERSION MID-EFFICIENCY SINGLE-STAGE INDUCED COMBUSTION FURNACES MODELS: P*HU/G8T-UH/L8T-UH/FL8 UPFLOW / HORIZONTAL P*DN/G8T-DN/L8T-DN

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST COMMERCIAL MODELS: 199 THRU 825 MODEL SIZES: 199, 260, 330, 400, 510. 625, 725, 825 MODEL TYPES: T, Ta, Tb, Tc, Td, Tx, WT, THWS, TIP, TIPR DATES OF MANUFACTURE: 08-01-81 THRU 09-30-82 MODELS: T, Ta, Tb,

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this

More information

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS 36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING

More information

installation instructions

installation instructions installation instructions GAS CONVERSION KIT PROPANE-TO-NATURAL P/N 315572-71201 4GAD 6GAD Cancels: IIK 4G-50-4 IIK 4G-50-5 7/15/91 NOTE: Read the entire instructions before starting the installation.

More information

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1* INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1* THIS KIT CONTAINS: AOPS7741 (NATURAL TO PROPANE CONVERSION PARTS FOR MODEL SIZE, 50) AOPS7742(NATURAL

More information

PARTS LIST. GF Sentry Series Infra-Red Salamander Broiler GFIR36C GFIR36 GFIR48 GFIR60. models. Parts & Service.

PARTS LIST. GF Sentry Series Infra-Red Salamander Broiler GFIR36C GFIR36 GFIR48 GFIR60. models. Parts & Service. GF Sentry Series Infra-Red Salamander Broiler models GFIR36C GFIR36 GFIR8 GFIR60 PARTS LIST Parts & Service T (USA & Canada): 800 7 6668 F (USA & Canada): 800 36 775 www.garland-group.com Garland Commercial

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS 00RX AND MSA HEAVY DUTY GAS GRIDDLES MODELS RX RX RX 0RX RX RX MSA MSA MSA MSA0 MSA MSA For additional information on Vulcan or to locate an authorized parts and service provider

More information

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L Commercial gas model A631265 Exterior 265L Commercial gas model A631265 Exterior 265L Item Part No. Description 1 221735 Foam cover 2 221914 Anode x 3 (black) 1153mm 2 221924 Anode x 3 (blue) 1153mm 3

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS HIGH ALTITUDE APPLICATION CONVERSION INSTRUCTION HIGH EFFICIENCY GAS FURNACES 1PS0306 / 1PS0307 / 1PS0308 / 1PS0309 / 1PS0901 / 1PS0902 / 1PS0903 FOR USE WITH MODELS:

More information

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet) Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet) INSTALLATION INSTRUCTIONS For R7 Series Light Commercial Packaged Gas Electric Units IIMPORTANT: Please

More information

Parts. Ultra 395/495/595t Ultra Max II 490/495/595t S. Korean patent VAC psi (228 bar, 22.8 MPa) Maximum Working Pressure

Parts. Ultra 395/495/595t Ultra Max II 490/495/595t S. Korean patent VAC psi (228 bar, 22.8 MPa) Maximum Working Pressure Parts Ultra 395/495/595t Ultra Max II 490/495/595t Korean patent 10--0579681 309675S EN 3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure 0 VAC Type Stand Series Lo-boy Series Hi-boy Series Ultra 395t

More information

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT LENND 2004 Lennox Industries Inc. DaItas, Texas, USA GAS KITS & ACCESSORIES Litho U.S.A. 504,986M 11/2004 HIGH ALTITUDE KIT INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KIT (83M75) USED WITH G43UF & G51MP

More information

Owners Manual Models 4430BF3, 4430BF2 & 4430BF1 Floor Mounted Tri-Level Bottle Filling Tubular Fountain

Owners Manual Models 4430BF3, 4430BF2 & 4430BF1 Floor Mounted Tri-Level Bottle Filling Tubular Fountain Owners Manual Models 4430F3, 4430F2 & 4430F1 Floor Mounted Tri-Level ottle Filling Tubular Fountain MODEL 4430F1L MODEL 4430F2UM INSTALLER 4430F Fountains are among the easiest to install Fountains on

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS For Burner Kit replacement of 553010021 Burners in GUI, GDI & GNI Gas Furnaces Using Natural Gas Please read these instructions completely before attempting installation. SAFETY

More information

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302 SL 40-399 G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302 If converting from Propane to Natural Gas, order the Natural Gas Conversion Parts Kit (IBC Part # P-303) from your authorized IBC Distributor.

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS Type 36C67 Combination (24 Volt Models) INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING

More information

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models GAS VALVE RETROFIT KIT Pull Through Tube Heater Models DESCRIPTION: This kit is designed to replace existing Honeywell gas valves #VR8205P and #VR8205Q with White-Rodgers gas valves #36J23 and #36J58 respectively

More information

ACCESSORY KIT INSTALLATION MANUAL

ACCESSORY KIT INSTALLATION MANUAL ACCESSORY KIT INSTALLATION MANUAL LP (PROPANE) CONVERSION KIT 1NP0366 FOR USE WITH MODELS: G8C & GF8 This conversion kit shall be installed by a qualified service agency in accordance with these instructions

More information

Natural Gas to L.P. Gas Conversion Kit

Natural Gas to L.P. Gas Conversion Kit Natural Gas to L.P. Gas Conversion Kit For Bosch 80% AFUE Gas Furnace, BGS80 Model Installation Instructions 3124627 2 Natural Gas to L.P. Gas Conversion Kit Installation Instructions Data subject to change

More information

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only Natural Gas High Altitude Conversion Kit United States Installations Only Installation Instructions Light Commercial Packaged Gas Electric Units R7TQ Series 6, - 7 1/2, & 10 Ton (2,001 FT - 10,000 FT)

More information

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33 INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33 FOR TWO-STAGE 90 PLUS DOWNFLOW/HORIZONTAL (-GTK) MODELS Recognize this symbol as an indication of Important Safety Information

More information

ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY

ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY 2004 ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 1 of 52 A-ARM, FLOOR PANEL, AND BUMPER ASSEMBLY 2004 ATV 90 Y-12 YOUTH 2-STROKE RED (A2004ATB2BUSR) Page 2 of 52 A-ARM, FLOOR PANEL, AND BUMPER

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models DESCRIPTION These kits are designed to convert from one gas type to another (eg. from NATURAL to PROPANE or from PROPANE to NATURAL) when equipped with White-Rodgers DSI gas valves number 36J23 or 36J58.

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! INLET PRESS TAP WHITE-RODGERS 36E93-304 Delay-Opening Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information

WARNING!! The attached Gold Medal Manual is for reference only and is not intended for any other purpose. The information contained in these on line manuals is subject to change at any time. Improvements

More information

Laars Combi Heat PV Gas Water Heater

Laars Combi Heat PV Gas Water Heater RESIDENTIAL GAS REPLACEMENT PARTS LIST Laars Combi Heat PV Gas Water Heater Document 11040 Effective: September, 2006 ECO 6885 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING REPLACEMENTS

More information

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41 INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41 FOR MODULATING DOWNFLOW/HORIZONTAL AND DEDICATED HORIZONTAL MODELS (-GGD, -GGE, -GGF)! Recognize this symbol

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS Type 36C04, 36C14 Step-Opening Combination Gas Control (24 Volt, 120 Volt & 750 mv Models) INSTALLATI INSTRUCTIS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW

More information

Natural Gas to L.P. Gas Conversion Kit

Natural Gas to L.P. Gas Conversion Kit Natural Gas to L.P. Gas Conversion Kit For Bosch 96% AFUE Gas Furnace, BGH96 Model Installation Instructions 3124627 2 Natural Gas to L.P. Gas Conversion Kit Installation Instructions Data subject to change

More information

Job Number Plant Location 123 Roadrunner Avenue, Tombstone, AR Fuel Devices

Job Number Plant Location 123 Roadrunner Avenue, Tombstone, AR Fuel Devices Combustion Services Safety Survey ETRO SERVICES Incorporated Customer Acme Incorporated Contact Name W. E. Coyote Job Number 5380 Plant Location 23 Roadrunner Avenue, Tombstone, AR 56884 Plant Name Test

More information

Propane Conversion Kit Instructions

Propane Conversion Kit Instructions 604 8 0/ US/CA For heating engineers Propane Conversion Kit Instructions Logano G4 X gas-fired boiler This conversion kit and the accompanying instructions are for conversion of G4 X gas-fired boilers

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS PROPANE TO NATURAL GAS CONVERSION KIT NAHA00801NG or PART NO. 1183389 TABLE OF CONTENTS Safety Considerations... 1 Introduction... 1 Description and Usage... 2 Induced Combustion,

More information

INSTALLATION GUIDE Gas Rangetops

INSTALLATION GUIDE Gas Rangetops INSTALLATION GUIDE Gas Rangetops Contents Wolf Gas Rangetops........................... 3 Safety Instructions............................ 4 Gas Rangetop Specifications.................... 5 Gas Rangetop

More information

Propane Conversion Kit Instruction

Propane Conversion Kit Instruction Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates Logamax plus GB62-80 kw 270,000 btu/hr Logamax plus GB62-00 kw 35,000 btu/hr This kit and instructions are for converting the

More information

User s Information Manual

User s Information Manual 48HC with EnergyX R System Factory Installed Energy Recovery Single---Package Rooftop Unit (RTU) Gas Heating/Electric Cooling Units 15 to 25 Nominal Tons with Puronr (R---410A) Refrigerant User s Information

More information

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28 INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28 FOR TWO-STAGE (GPL/GPR/GPE/GLL/GLR/GLE) MODELS Recognize this symbol as an indication of Important Safety Information THESE

More information

IPG IGNITION GAS PILOTS BACK-LOADED GAS

IPG IGNITION GAS PILOTS BACK-LOADED GAS INSTRUCTIONS IPG IGNITION GAS PILOTS BACK-LOADED GAS WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CTROL COULD CAUSE PERSAL INJURY AND/OR PROPERTY DAMAGE.

More information

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS INLET PRESS TAP WTE-RODGERS 36E96-314 DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL

More information

GAS FRYER Instruction Manual Model #5099NS

GAS FRYER Instruction Manual Model #5099NS Part No. 89932 Revised: March 2004 GAS FRYER Instruction Manual Model #5099NS Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS GAS FUNNEL CAKE FRYER 2 MODEL #5099NS GAS FUNNEL CAKE FRYER SAFETY PRECAUTIONS

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 FOR USE WITH 90% MODELS: GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V, FC9V, GM9V,

More information

/2004 US/CA

/2004 US/CA 630 9765 0/004 US/CA For the contractor Propane Conversion Kit Instructions Sealed Combustion Gas Boiler Logano GA44 This kit and instructions are for converting the GA44 model boilers from Natural Gas

More information

36H SERIES Combination Gas Valve

36H SERIES Combination Gas Valve FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 36H series combination gas valve is

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 36C53 Combination Gas Valves (24 Volt Model) INSTALLATI INSTRUCTIS Electrical Rating: Voltage: 24 Volts, (30 Volts Max.), 60 Hz. Current Rating: 0.23 Amps Type of Gas Natural Gas Pressure

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

BURNERS NOZZLE MIX SINGLE TUNNEL MULTIPLE TUNNEL

BURNERS NOZZLE MIX SINGLE TUNNEL MULTIPLE TUNNEL MODEL: 3501 - Single Tunnel 3506 - Multiple Tunnel Revision: 0 BULLETIN 3501 & 3506 8001 NM FEATURES High heat inputs - intense combustion Excellent flame stability Wide turndown range - greater than 10:1

More information

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS INLET PRESS TAP WTE-RODGERS 36E54-214 DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide SUMMITTM 400 & 600 Natural Gas Barbecues Step-By-Step Guide W E B E R W E B E R W E B E R W E B E R Summit 400 NG Summit 600 NG CANADIAN GAS ASSOCIATION R A P P R O V E D WARNING: Follow all leak check

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 FOR USE WITH 90% MODELS: GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V, FC9V, GM9V,

More information

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS INLET PRESS TAP WHITE-RODGERS 36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

Service Parts Manual Drawer Microwave Models: MWD24-2 & MWD30-2

Service Parts Manual Drawer Microwave Models: MWD24-2 & MWD30-2 Service Parts Manual 28 14 40 49 68 29 73 5 11 55 38 75 56 4 44 8 7 45 1 52 2 22 10 46 50 71 25 26 62 15 27 3 24 48 9 39 57 13 63 39 74 36 64 51 53 50 6 35 66 42 70 21 18 37 55 16 17 76 60 33 67 19 54

More information

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay. Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.

More information

Conversion instructions from natural gas to propane

Conversion instructions from natural gas to propane 6 720 804 895 202/0 EN-US For heating engineers Conversion instructions from natural gas to propane Room air-independent special gas-fired boiler Logano GA24 This conversion kit and the instructions are

More information

LENNOX SLP98UHV DIAGNOSTIC CODES

LENNOX SLP98UHV DIAGNOSTIC CODES Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second

More information

LGB Series 1 & 2 Section And Base Assembly

LGB Series 1 & 2 Section And Base Assembly LGB Series 1 & 2 Section And Base Assembly Current Service Parts 263 LGB Series 1 & 2 Section And Base Assembly Fig. Part Size Description 383-300-405 Section replacement kit, Includes seals, rope and

More information

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED VULCAN 36RB 36IRB WOLF C36RB C36IRB This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not

More information

Spare parts list ( ) Spare parts list HDS 990

Spare parts list ( ) Spare parts list HDS 990 Spare parts list (5.952-855.0) Spare parts list HDS 990 13.10.2014 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 990 (5.952-855.0)... 6 10 Individual parts... 7 49 Spare

More information

Spare parts list ( ) Spare parts list HDS 700 B

Spare parts list ( ) Spare parts list HDS 700 B Spare parts list (5.955-875.0) Spare parts list HDS 700 B 02.09.2013 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 700 B (5.955-875.0)... 6 10 Individual parts... 7 11

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 6C8-5 Combination Gas Control INSTALLATI INSTRUCTIS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS

More information

DANGER WARNING IMPORTANT

DANGER WARNING IMPORTANT BWC Series Instructions for Field Conversion From: Natural Gas to LP LP to Natural Gas D E S I G N E D T O L E A D DANGER These instructions include a procedure for adjusting the air-fuel mixture on this

More information

55.109/1. BUT: Three-way unit valve, PN 16. Sauter Components

55.109/1. BUT: Three-way unit valve, PN 16. Sauter Components 55.109/1 UT: Three-way unit valve, PN 16 How energy effiieny is improved Linear mixture and no leak losses in the ontrol passage for energy-effiient regulators. reas of appliation Regulating valve for

More information

PGM365 Cooktop. 2-3 Chassis Assembly* 4 Burner Tubes* 5-6 Top Frame Assembly. 7 Wiring and Lights

PGM365 Cooktop. 2-3 Chassis Assembly* 4 Burner Tubes* 5-6 Top Frame Assembly. 7 Wiring and Lights Customer Contact Number: PGM365 Cooktop IMPORTANT: PGM series cooktops that do not have a -1 at the end of the model number may have some parts that are No Longer Available (NLA). If the part you need

More information

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

SWIRLFLO Refrigerated fountains with FLEXI-GUARD TM INSTALLATION, CARE & USE MANUAL SWIRLFLO Refrigerated fountains with FLEXI-GUARD TM INSTALLER! CAUTION: Review these instructions before beginning installation. Be sure that installation conforms to

More information