1 RKKB Parts ist This parts list is current as of the above revision date. See for the current revision. Package Gas-Electric - ommercial

2 Table of ontents odel Explanation Page 3 Parts Numbers rawings/photographs Panels - iscellaneous Page 4 Panels - iscellaneous Page 5 Panels - iscellaneous Page 6 Panels - iscellaneous Page 7 Electrical Group Page 8 Fan Group Page 10 Blower Group Page 11 Blower Group Page 12 Blower Group Page 13 oil Parts Page 14 oil Parts Page 15 ompressor Group Page 16 ompressor Group Page 17 Heat Exchanger-Burner Group Page 18 Heat Exchanger-Burner Group Page 19 Heat Exchanger-Burner Group Page 20 Gas ontrols Page 21 ccessories Page 22 Orifice Selection hart Page 23 Exploded View Page 24 Exploded View Page 25 Filter Rack ssembly Page 26 oil ssembly Page 26 Filter Rack - oil ssembly Page 27 ontrol Board ssembly Page 28 ontrol Board ssembly Page 28 Blower ssembly Page 29 Blower ssembly Page 29 Heat Exchanger ssembly Page 30 Heat Exchanger ssembly Page 30 Notes/isclaimer Page 31 Page 2 of 31

3 NUBER EXPNTION R K K B E TRENE 7 EETRI ESIGNTION = /3/60 2 K - ROOFTOP OERI = 460/3/60 N = /3/50 3 EFFIIEN ESIGNTION P = /3/50 K = Standard Efficiency (10 SEER) = 575/3/60 = High Efficiency (12 SEER) 8 RIVE PKGE 4 ESIGN SERIES = Belt rive = Belt rive - High Static 5 TEHNI VRITIONS 9 HETING PIT - (BH) 6 (BTU/HR) 12 =, = 290,000 = 90,000 / =, =, =,000 =,000 =, =, = 330,000 =,000 =, = 210, = 350,000 =, = 225, = 400, = 252, IGNITION SSTE E = Electric SERI NUBER EXPNTION 1 Z F GS OE 6 TEHNOOG VRITIONS 2 OPRESSOR IENTIFITION NO. 7 PROUTION OTION F = Fort Smith, R 3 IGNITION EVIE 8 TE OE 4 INUER BOWER 9 PROUTION NUBER 5 HET EXHNGER Page 3 of 31

4 TEHNI VRITIONS / PNES, ISENEOUS PRTS - BSE RIS, INSIE PNES BSE RIS: Front E E E E B Right E E E E Rear E E E E eft E E E E BSE PNS: E Outdoor oil Base Pan S S S S F Indoor oil Base Pan S S S S INSIE BINET PNE/PIEES: G Entry Plate E E E E H Entry Plate E E E E J Heat ompartment Side E E E E K Blower eck S S S S Wireway E E E E ondenser Bulkhead S S S S N Tube Support Right ngle E E E E P Tube Support eft ngle E E E E R imit over S S S S Page 4 of 31

5 TEHNI VRITIONS / PNES, ISENEOUS PRTS - FRONT FRONT: 1 ontrol Box / Filter ccess Panel S S S S Hinge Hinge eft - Front Panel S S S S ontrol Box over E E E E ontrol ounting Plate E E E E ow Voltage Shield E E E E ontrol Box Back S S S S Bracket E E E E Inlet Flue Hood E E E E Flue Hood S S S S a Gas Furnace ccess Panel S S S S b Hinge c Hinge Gas Pipe Support Plate S S S S Blower ccess Panel S S S S Right - Front Panel S S S S Heat Exchanger ounting Frame S S S S ondenser oil ccess Panel-Front E E E E Front orner Post E E E E TEHNI VRITION / PNES, ISENEOUS PRTS - RIGHT, EFT, N TOP RIGHT: N/ N/ 19 ir Stop E E S S ouvered Panel S S RER 21 Rear orner Post E E E E ondenser oil ccess Panel - Rear E E S S Rear Panel S S S S Supply over S S S S Return over S S S S EFT: 26 Upper eft Panel S S S S ower eft Panel S S S S eft orner Panel S S S S Receptacle Plate-Inside Panel E E E E isconnect Plate-Install Panel E E E E Button Plug Button Plug TOP: 33 Top Panel S S S S ondenser Top Panel S S S S Venturi E E E E Wire Grille Page 5 of 31

6 TEHNI VRITIONS PNES, ISENEOUS PRTS - BSE RIS, INSIE BINET BSE RIS: Front S S S B Right E E E Rear S S S eft E E E BSE PNS: E Outdoor Base Pan S S S F Indoor oil Base Pan - Return ir S S S G Indoor oil Base Pan - Supply ir S S S INSIE BINET PNE/PIEES: H Entry Plate E E E J Heat ompartment Side E E E K Blower eck S S S Wireway E E E ondenser Bulkhead S S S N Tube Support Right ngle E E E R imit over S S S S ir Stop - Outdoor oil- Front E E E T ir Stop - Outdoor oil- Rear E E E U oil ounting ngle E E E W Outdoor oil ivider Panel E E E X oil Support Brace E E E ondenser oil- ir Stop Rear E E E Z ondenser oil- ir Stop Front E E E TEHNI VRITIONS PNES, ISENEOUS PRTS - FRONT N RIGHT SIES 1 ontrol Box / Filter ccess Panel S S S Hinge Hinge eft - Front Panel S S S ontrol Box over E E E ontrol ounting Plate E E E ow Voltage Shield E E E ontrol Box Back S S S Bracket E E E Inlet Flue Hood E E E Flue Hood S S S a Gas Furnace ccess Panel See Heat Exchanger / Burner Group 12b Hinge c Hinge Gas Pipe Support Plate S S S Blower ccess Panel S S S Right - Front Panel S S S Heat Exchanger ounting Frame S S S ouvered Panel - arge E E E ouvered Panel - Small E E E Front/ Rear Post - iddle E E E ondenser ccess Panel E E E Front/ Rear orner Post E E E Page 6 of 31

7 TEHNI VRITIONS PNES, ISENEOUS PRTS - TOP, RER N EFT SIES RER: 17 ouvered Panel - arge E E E ouvered Panel - Small E E E Front/ Rear Post - iddle E E E Front/ Rear orner Post E E E Right Rear Panel S S S eft Rear Panel S S S Supply over S S S Return over S S S EFT: 26 Upper eft Panel S S S ower eft Panel S S S eft orner Panel S S S Bracket E E E Gasket for receptacle plate Gasket for disconnect plate Plate - Install inside Panel - Receptacle E E E Plate - Install inside Panel - isconnect E E E TOP: 31 Outdoor Top Front Panel E E E Outdoor Top Rear Panel E E E Outdoor Top Support E E E Top Panel S S S Venturi E E E Wire Grille Page 7 of 31

8 No. Notes TEHNI VRITION EETRI ESIGNTION -/ /P - - N N -/ EETRI GROUP ONTRO BOX OPONENTS: 6 Stk ontrol Box ounting Panel E E E E E E Integrated Furnace ontrol See Gas ontrols 57 Stk Transformer (Before F2301) Stk Transformer (fter F2301) ouble Row Terminal Block Stk Blower ontactor Run apacitor See Fan Group ow Voltage Terminal Block - 7 terminal block pieces are used in this application. The replacement is a kit that includes 13 terminal block pieces and 1 end piece. Order the amount of kits based on the replacement needed. 61 ow Voltage Terminal Block Stk ompressor ontactor Stk Step own Transformer (Before F2301) N/ N/ N/ Stk Step own Transformer (fter F2301) N/ N/ N/ N/ N/ Induced raft Relay (fter F2301) N/ N/ Wiring Harness - Furnace ontrol (Before F0499) Wiring Harness - Furnace ontrol (fter F0499) Wiring Harness - Outdoor Fan See Fan Group Wiring Harness - Economizer Wiring Harness - ompressor See ompressor Group Wiring Harness - Induced raft Blower See Heat Exchanger Group Bypass Plug - Economizer 12 Pin S S S S S S Induced raft Relay (fter F2301) N/ N/ No. Notes TEHNI VRITION EETRI ESIGNTION // // // N // P // EETRI GROUP 56 Integrated Furnace ontrol See Gas ontrols 62a Stk ompressor ontactor - abel b Stk ompressor ontactor - abel c Stk ompressor ontactor - abel d Stk ompressor ontactor - abel a Run apacitor - abel R 1 See Fan Group 60b Run apacitor - abel R 2 See Fan Group 60c Run apacitor - abel R 3 See Fan Group 60d Run apacitor - abel R 4 See Fan Group 38 Terminal Block - abel TB Note: ow Voltage Terminal Block - 7 terminal block pieces are used in this application. The replacement is a kit that includes 13 terminal block pieces and 1 end piece. Order the amount of kits based on the replacement need. 61 ow Voltage Terminal Block - abel TB a ouble Row Terminal Block - abel TB b ouble Row Terminal Block - abel TB Wiring Harness - Furnace ontrol Wiring Harness - Outdoor Fan See Fan Group Wiring Harness - Economizer Wiring Harness - ompressor See ompressor Group Wiring Harness - Induced raft Blower See Heat Exchanger Group Bypass Plug - Economizer 12 Pin S S S S S Pressure Switch Heat Exchanger / Burner Group 85 ain imit Heat Exchanger / Burner Group Note: The following date code changes are related to the change in the Induced raft Blower otor in the Heating Group. ate ode before F Stk Transformer - abel T a Stk Transformer abel PT 1 N/ N/ b Stk Transformer abel PT 2 N/ N/ c Stk Transformer abel PT 3 N/ N/ d Stk Transformer abel PT 4 N/ N/ Stk Blower ontactor - abel B ate ode after F Stk Transformer - abel T a Transformer abel PT 1 N/ N/ N/ N/ b Transformer abel PT 2 N/ N/ N/ N/ c Transformer abel PT 3 N/ N/ N/ N/ d Transformer abel PT 4 N/ N/ N/ N/ Stk Induced raft Relay - abel IR 1 N/ N/ N/ Stk Induced raft Relay - abel IR 2 N/ N/ N/ Terminal Block - abel TB 3 N/ N/ N/ Page 8 of 31

9 59 Stk Blower ontactor - abel B Page 9 of 31

10 TEHNI VRITION EETRI ESIGNTION /N FN GROUP 52 Stk Fan otor Wiring Harness - Outdoor Fan Wiring Harness - Outdoor Fan 2 N/ N/ N/ Stk Fan Blade Stk Plastic ap for Fan otor Stk otor ount - Outdoor Fan a, Stk Run apacitor b TEHNI VRITION EETRI ESIGNTION /N FN GROUP 52 Stk Fan otor Wiring Harness - Outdoor Fan Wiring Harness - Outdoor Fan Stk Fan Blade Stk Plastic ap for Fan otor Stk otor ount - Outdoor Fan a, Stk Run apacitor b /N TEHNI VRITION EETRI ESIGNTION /P /N FN GROUP 52 Stk Fan otor Wiring Harness - Outdoor Fan Wiring Harness - Outdoor Fan Stk Fan Blade Stk Plastic ap for Fan otor otor ount - Outdoor Fan a, Stk Run apacitor b TEHNI VRITION EETRI ESIGNTION / /P / /N / FN GROUP 52 Stk Fan otor Stk Fan Blade Wiring Harness - Outdoor Fan Wiring Harness - Outdoor Fan Wiring Harness - Outdoor Fan Wiring Harness - Outdoor Fan Stk otor Fan ap otor ount - Outdoor Fan Stk Run apacitor /N Page 10 of 31

11 TEHNI VRITION RIVE PKGE BOWER SSEB GROUP - BET RIVE 64 Stk Blower ssembly (ess otor, Belt and Pulley) S S S S S Scroll Side an not be ordered individually, order - S Scroll Side an not be ordered individually, order - S Scroll Wrap an not be ordered individually, order - S Stk Blower Wheel Bearing Frame Tri-rm Stk Bearing with Bearing ock Stk Blower Shaft Blower ounting ngles E E E E E otor ount E E E E E TEHNI VRITION EETRI ESIGNTION RIVE PKGE / / / OTOR, BET N VRIBE PITH SHEVE FOR BOWER SSEB BET RIVE 71 Stk Blower otor Stk Variable Sheave Stk Belt Stk Fixed Sheave w/bushing Stk Bushing / / TEHNI VRITION EETRI ESIGNTION RIVE PKGE N/P N/P N/P OTOR, BET N VRIBE PITH SHEVE FOR BOWER SSEB BET RIVE 71 Stk Blower otor Stk Variable Sheave Stk Belt Stk Fixed Sheave w/bushing Stk Bushing N/P N/P TEHNI VRITION EETRI ESIGNTION RIVE PKGE OTOR, BET N VRIBE PITH SHEVE FOR BOWER SSEB BET RIVE 71 Stk Blower otor Stk Variable Sheave Stk Belt Stk Fixed Sheave w/bushing Stk Bushing Page 11 of 31

12 TEHNI VRITION RIVE PKGE BOWER SSEB GROUP - BET RIVE 64 Stk Blower ssembly (ess otor, Belt and Pulley) S S S S S Scroll Side an not be ordered individually, order - S Scroll Side an not be ordered individually, order - S Scroll Wrap an not be ordered individually, order - S Stk Blower Wheel Bearing Frame Tri-rm Stk Bearing w/bearing ock Stk Blower Shaft Blower ounting ngles E E E E E otor ount E E E E E TEHNI VRITION EETRI ESIGNTION RIVE PKGE OTOR, BET N VRIBE PITH SHEVE FOR BOWER SSEB BET RIVE 71 Stk Blower otor Stk Variable Sheave Stk Belt Stk Fixed Sheave includes Bushing Stk Bushing TEHNI VRITION EETRI ESIGNTION RIVE PKGE OTOR, BET N VRIBE PITH SHEVE FOR BOWER SSEB BET RIVE 71 Stk Blower otor Stk Variable Sheave Stk Belt Stk Fixed Sheave includes Bushing Stk Bushing TEHNI VRITION EETRI ESIGNTION RIVE PKGE N/P N/P N/P OTOR, BET N VRIBE PITH SHEVE FOR BOWER SSEB BET RIVE 71 Stk Blower otor Stk Variable Sheave Stk Belt Stk Fixed Sheave includes Bushing Stk Bushing N/P N/P TEHNI VRITION EETRI ESIGNTION RIVE PKGE OTOR, BET N VRIBE PITH SHEVE FOR BOWER SSEB BET RIVE 71 Stk Blower otor Stk Variable Sheave Stk Belt Stk Fixed Sheave includes Bushing Stk Bushing Page 12 of 31

13 TEHNI VRITION RIVE PKGE - / - / - / BOWER SSEB GROUP - BET RIVE 64 Stk Blower ssembly S S S Scroll Side an not be ordered individually Scroll Side an not be ordered individually Scroll Wrap an not be ordered individually 65 Stk Blower Wheel Stk Bearing Frame Tri-rm Stk Bearing with Bearing ock Stk Blower Shaft Blower ounting ngles E E E otor ount E E E Blower onnector E E E TEHNI VRITION EETRI ESIGNTION RIVE PKGE //N/P //N/P OTOR, BET N VRIBE PITH SHEVE FOR BOWER SSEB BET RIVE 71 Stk Blower otor Stk Variable Sheave Stk Belt Stk Fixed Sheave includes Bushing Stk Bushing TEHNI VRITION EETRI ESIGNTION RIVE PKGE //N/P //N/P OTOR, BET N VRIBE PITH SHEVE FOR BOWER SSEB BET RIVE 71 Stk Blower otor Stk Variable Sheave Stk Belt Stk Fixed Sheave includes Bushing Stk Bushing TEHNI VRITION EETRI ESIGNTION RIVE PKGE //N/P //N/P OTOR, BET N VRIBE PITH SHEVE FOR BOWER SSEB BET RIVE 71 Stk Blower otor Stk Variable Sheave Stk Belt Stk Fixed Sheave includes Bushing Stk Bushing Page 13 of 31

14 No. Notes TEHNI VRITION OI GROUP ONENSER OI: 37a Stk ondenser oil - Outdoor S S S S S b Stk ondenser oil - Outdoor N/ N/ N/ S S Front ir Stop N/ N/ N/ E E Rear ir Stop N/ N/ N/ E E Bottom Retainer N/ N/ N/ E E a Top Support ondenser oil N/ N/ N/ E E b Top Support ondenser Bulkhead N/ N/ N/ E E EVPORTOR OI: 42 Stk omplete oil - Indoor S S S S S Stk ap Tube / Flowcheck istributor S S S S Stk rain Pan FITER PIEES: 44a,b Filter Frame E E E E E ir Stop Bottom E E E E E Stop ir Stop E E E E E Top ir Stop S S S S S a,b Filter hannel S S S S S Filter hannel E E E E E Filter (6) Filter Slide E E E E E Page 14 of 31

15 No. Notes TEHNI VRITION EETRI ESIGNTION // N/P EVPORTOR OI EVPORTOR OI: 42 Stk omplete oil - Indoor S S S S S S ap Tube ssembly - ircuit 1 (See Note 5) S ap Tube ssembly - ircuit 2 (See Note 5) S ap Tube ssembly - ircuit 3 (See Note 5) S ap Tube ssembly - ircuit 4 (See Note 5) S ir Flow Panel E E E E E E rain Pan ounting ngle E E E E E E Stk rain Pan // N/P // N/P No. Notes TEHNI VRITION ONENSER OI ONENSER OI: 37a Stk ondenser oil - Front S S S b Stk ondenser oil - Rear S S S No. Notes TEHNI VRITION ONENSER OI FITER PIEES: 39 Filter Frame ssembly S S S a Filter Frame E E E b Filter Frame E E E ir Stop - Side E E E Filter hannel S S S ir Stop Bottom E E E Top ir Stop S S S a/b Filter hannel E E E Filter (6) 50 18"x18"x2" "x24"x2" Filter Slide E E E Page 15 of 31

16 TEHNI VRITION EETRI ESIGNTION OPRESSOR GROUP ompressor I: Stk ompressor - ircuit One S S S S Stk ompressor - ircuit Two S S S S S Harness - ompressor Harness - ompressor TEHNI VRITION EETRI ESIGNTION OPRESSOR GROUP ompressor I: Stk ompressor - ircuit One S S S S S S 75 Stk ompressor - ircuit Two S S S S S S Harness - ompressor Harness - ompressor ompressor I: Stk ompressor - ircuit One S 75 Stk ompressor - ircuit Two S Harness - ompressor Harness - ompressor N N N N TEHNI VRITION EETRI ESIGNTION N P OPRESSOR GROUP ompressor I: Stk ompressor - ircuit One S S S S S Stk ompressor - ircuit Two S S S S S S Harness - ompressor Harness - ompressor Page 16 of 31

17 TEHNI VRITION EETRI ESIGNTION OPRESSOR GROUP ompressor I: Stk ompressor S S S S S S Harness - ompressor Harness - ompressor Harness - ompressor Harness - ompressor N TEHNI VRITION EETRI ESIGNTION N N P OPRESSOR GROUP ompressor I: Stk ompressor S S S S S Harness - ompressor Harness - ompressor Harness - ompressor Harness - ompressor Page 17 of 31

18 TEHNI VRITION HETING PIT , 25 HET EXHNGER, BURNER / NIFO 76 Stk Heat Exchanger S S S S S Turbulators E E E E E (6) (9) (6) (9) (9) 78 Inducer ounting Plate Gasket Inducer ounting Plate E E E E E Gasket - Induced raft Blower Note: Induced raft Blower is 230 V, and is 460 V. Verify original part before replacing. 81 Stk Induced raft Blower w/gasket - Voltages /P/ N/ N/ Stk Induced raft Blower w/gasket - Voltages /N - Before F Stk Induced raft Blower w/gasket - Voltages /N - fter F Wiring Harness - Induced raft Blower (Voltages //N/P/) Stk Flue uct Gasket - Flue uct Stk Pressure Switches Pressure Switch ounting Bracket - Before F1909 E E E E E Pressure Switch ounting Bracket - fter F1909 E E E E E Stk imit - ain imit (Heat Exchanger Panel) Stk Spark Ignitor Stk Flame Sensor Stk imit - anual Reset (Burner ompartment) Burner Support E E E E E Burner Support Brackets E E E E E Stk Burner ssembly S S S S S Heat Shield E E E E E Stk anifold (w/o Orifices) Square Head Plug (Used to plug unused holes on anifold) Burner Orifices - Natural Gas See Orifice Selection hart 95 Burner Orifices - P See Orifice Selection hart Number of Orifices Page 18 of 31

19 TEHNI VRITION HETING PIT 21 HET EXHNGER, BURNER/NIFO 12a Gas Furnace ccess Panel S S S S Stk Heat Exchanger S S S S Turbulators E E E E (10) (10) (14) (14) 78 Inducer ounting Plate Gasket Inducer ounting Plate E E E E Stk Gasket - Induced raft Blower Note: Induced raft Blower is 230 V, and is 460 V. Verify original part before replacing. 81 Stk Induced raft Blower w/gasket - Voltages /P/ Stk Induced raft Blower w/gasket - Voltages /N - Before F Stk Induced raft Blower w/gasket - Voltages /N - fter F Wiring Harness - Induced raft Blower (Voltages //N/P/) Transformer See Electric Group 82 Flue uct Gasket - Flue uct (6) (6) 83a Stk Pressure Switch - eft N/ N/ b Stk Pressure Switch - iddle eft c Stk Pressure Switch - iddle Right d Stk Pressure Switch - Right N/ N/ N/ N/ 84a Pressure Switch ounting Bracket - (Single ount) - Before F1909 E E E E a Pressure Switch ounting Bracket - (Single ount) - fter F1909 E E E E b Pressure Switch ounting Bracket (ual ount) E E E E Stk imit - ain imit (Heat Exchanger Panel) Stk Spark Ignitor Stk Flame Sensor Stk imit - anual Reset (Burner ompartment) Burner Support S S S S Burner Support Brackets E E E E Stk Burner ssembly S S S S Heat Shield E E E E Stk anifold (w/o Orifices) Square Head Plug (Used to plug unused holes on anifold) Burner Orifices - Natural Gas See Orifice Selection hart 95 Burner Orifices - P See Orifice Selection hart Number of Orifices Page 19 of 31

20 TEHNI VRITION HETING PIT / 25 / 30 / 33 / 40 HET EXHNGER, BURNER / NIFO 12a Gas Furnace ccess Panel S S S S Stk Heat Exchanger S S S S Turbulators E E E E (12) (12) (14) (14) 78 Inducer ounting Plate Gasket Inducer ounting Plate E E E E Note: Induced raft Blower is 230 V, and is 460 V. Verify original part before replacing. 80 Stk Gasket - Induced raft Blower Stk Induced raft Blower w/gasket - Voltages /P/ Stk Induced raft Blower w/gasket - Voltages /N - Before F Stk Induced raft Blower w/gasket - Voltages /N - fter F Wiring Harness - Induced raft Blower (Voltages //N/P/) Transformer See Electric Group 82 Flue uct Gasket - Flue uct (6) (6) (8) (8) 83a Stk Pressure Switch - eft b Stk Pressure Switch - iddle eft c Stk Pressure Switch - iddle Right d Stk Pressure Switch - Right N/ N/ a Pressure Switch ounting Bracket - (Single ount) - Before F1909 E E E E a Pressure Switch ounting Bracket - (Single ount) - fter F1909 E E E E b Stk Pressure Switch ounting Bracket (ual ount) E E E E Stk imit - ain imit (Heat Exchanger Panel) Stk Spark Ignitor Stk Flame Sensor Stk imit - anual Reset (Burner ompartment) Burner Support S S S S Burner Support Brackets E E E E Stk Burner ssembly S S S S Stk Heat Shield E E E E Stk anifold (w/o Orifices) Square Head Plug (Used to plug unused holes on anifold) Burner Orifices - Natural Gas See Orifice Selection hart 95 Burner Orifices - P See Orifice Selection hart Number of Orifices Page 20 of 31

21 GS OE 1Z 2 2B 2 2F 2H GS ONTROS 56 Stk Integrated Furnace ontrol See Note (See Note 4) 2K Stk Gas Valve - Natural Gas (Before F0308) See Note (See Note 4) Stk Gas Valve - Natural Gas (fter F0308) See Note (See Note 4) Stk,2 Gas Valve - P See Note 2 See Note 1 See Note 2 See Note 3 See Note 2 See Note 2 (See Note 4) See Note 2 97 Stk Street Elbow See Note (See Note 4) Nipple Blk N/ See Note 1 N/ N/ N/ N/ eg Elbow Std N/ See Note 1 N/ N/ N/ N/ Stk P onversion Kit EP-87W See Note 1 EP-86W FP-14 EP-86W EP-86W FP-24 Page 21 of 31

22 TEHNI VRITION FTOR INSTE OPTIONS / FIE INST ESSORIES ouver Panel - Option Time elay Relay - Option High Pressure / ow Pressure ontrol Factory Installed Option Freeze Stat - Option onvenience Outlet - Option isconnect Switch Kit - Option ow mbient ontrol - Option - RXRX-01 RX-04 RXRX-K01 RXRX-01 RXRX-N01 RXRX-P01 RXRZ-90 TEHNI VRITIONS Time elay Relay Freeze Stat onvenience Outlet isconnect Switch Kit ow mbient ontrol arbon ioxide Sensor otorized Fresh ir anual Fresh ir FTOR INSTE OPTIONS / FIE INST ESSORIES // RX-05 RXRX-01 RXRX-N01 RXRX-P01 RXRZ-90 RXRX-R01 RXRX-T01 RXRF-GE1 Outdoor ir Sensor Field Install Single Enthalpy Field ual Enthalpy EONOIZERS -, RXR-E2 RXR-E3 RXR-E4 Outdoor ir Sensor Single Enthalpy ual Enthalpy EONOIZERS // RXR-EF2 RXR-EF3 RXR-EF4 TEHNI VRITION Power Exhaust - Voltage Power Exhaust - Voltage Power Exhaust - Voltage POWER EXHUST - RXRX-BFF02 RXRX-BFF02 RXRX-BFF02 Page 22 of 31

23 PKGE EQUIPENT - ORIFIE SEETION HRT - NTUR GS UTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation: 1) Furnace Input Rating (BTU/HR) 2) Number of Burners 2) ltitude (ft.) For detailed information and instructions for Orifice selection, see the Gas Furnace P onversion Kit Index and the latest edition of the National Fuel Gas ode Handbook, or the National Standard of anada, Natural Gas and Propane Installation ode, N B UTION: This information is provided for replacement purposes only. onversion for operation at High ltitude must be done using the kit specified on the product specification sheet for the unit. NOTE: This Orifice sizing chart is based on a Natural Gas heating value of 1075 BTU/cu. ft and a pressure setting of 3.5 in. water column. NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of ft. anadian High Elevation (ft.) Furnace Number ltitude erated ountry Input of Input Rating (BTU/HR) Burners (BTU/HR) U.S. U.S. U.S. U.S. anada anada 40,000 36, ,000 54, ,000 N/ N/ 80,000 72, ,000 N/ N/ 100,000 90, , , , , , , ,000 N/ N/ 210,000 N/ N/ 210,000 N/ N/ 225, , , , , , ,000 N/ N/ 290,000 N/ N/, , ,000 N/ N/ 350, , , , PKGE EQUIPENT - ORIFIE SEETION HRT - P UTION: Selection of the correct P Orifice requires the following information for the specific installation: 1) Furnace Input Rating (BTU/HR) 2) Number of Burners 2) ltitude (ft.) For detailed information and instructions for Orifice selection, see the Gas Furnace P onversion Kit Index and the latest edition of the National Fuel Gas ode Handbook, or the National Standard of anada, Natural Gas and Propane Installation ode, N B UTION: This information is provided for replacement purposes only. onversion to P or for operation at High ltitude should be done using the kit(s) specified on the product specification sheet for the unit. NOTE: This Orifice sizing chart is developed using the specified pressure setting of 10 in. water column instead of the 11.0 in water column used by the NFG and NB NOTE: Orifices supplied in the P onversion Kit are calculated and sized based on a heating value of 2500 BTU/cu. ft. and an elevation of ft. anadian High Elevation (ft.) Furnace Number ltitude erated ountry Input of Input Rating (BTU/HR) Burners (BTU/HR) U.S. U.S. U.S. U.S. anada anada 40,000 36, ,000 54, ,000 N/ N/ 80,000 72, ,000 N/ N/ 100,000 90, , , , , , , ,000 N/ N/ 210,000 N/ N/ 210,000 N/ N/ 225, , , , , , ,000 N/ N/ 290,000 N/ N/, , ,000 N/ N/ 350, , , , Page 23 of 31

24 Exploded View - Page 24 of 31

25 Exploded View Page 25 of 31

26 Filter Rack ssembly - oil ssembly - Page 26 of 31

27 Filter Rack - oil ssembly Page 27 of 31

28 ontrol Board ssembly - ontrol Board ssembly Page 28 of 31

29 Blower ssembly - Blower ssembly Page 29 of 31

30 Heat Exchanger ssembly - Heat Exchanger ssembly Page 30 of 31

31 NOTES Stk It is recommended that stock be maintained for this part. N/ Not pplicable 1 small number of early production series were built with "2B" gas control components, but were labeled with a " 2" serial number. The units labeled with " 2" have the " 2B" gas control parts. 2 Order the specified P onversion Kit. 3 Order Gas Valve for Natural Gas along with P onversion Kit. 4 Some 15 ton models with "2" gas control components were incorrectly labeled with a " 2H" serial number. These units labeled with " 2H" have the " 2" gas control parts. 5 ircuit numbering orientation is from bottom to top of coil. ISIER: This document is intended to provide general replacement parts information to aid qualified service personnel in the repair of these models. The complete odel and Serial Number of the unit under repair should be specified when selecting and ordering replacement parts. Specifications and illustrations are subject to change without notice. ocument supersedes all previous parts lists for these models. See for the latest revision of this document. The manufacturer assumes no obligation for errors or omissions. Service personnel must verify the proper and safe operation of equipment after the replacement of any original components. P.O. Box Fort Smith, R

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. RKN Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/.pdf for the current revision. Package Gas-Electric - ommercial Table of ontents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. RKK Parts ist This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-rkk.pdf for the current revision. Package Gas-Electric - Commercial Table of Contents

More information

MHS BY(Y)

MHS BY(Y) -(Y) Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807--(Y) Table

More information

MHS BY(D)

MHS BY(D) 003-010() Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807-003-010()

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. RK arts ist This parts list is current as of the above revision date. See http://www.rheempartslists.net/.pdf for the current revision. ackage ir Conditioners - Commercial Table of Contents odel Explanation...................................................................................................................

More information

MPS-003AG-005AG

MPS-003AG-005AG 003- Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807-003- Table

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. ondensing Units Table of ontents Model Explanation...................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps - Commercial Table of Contents Model Explanation...................................................................................................................

More information

UPNE. Heat Pumps. Parts List 19-July-2011

UPNE. Heat Pumps. Parts List 19-July-2011 Parts List 19-uly-2011 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-.pdf for the current revision. Heat Pumps Table of ontents Model Explanation...................................................................

More information

RPMD. Heat Pumps. Parts List 02-October-2017

RPMD. Heat Pumps. Parts List 02-October-2017 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of ontents Model Explanation...................................................................................................................

More information

RPLA. Heat Pumps. Parts List 19-July-2011

RPLA. Heat Pumps. Parts List 19-July-2011 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................

More information

RPNK. Heat Pumps. Parts List 25-July-2011

RPNK. Heat Pumps. Parts List 25-July-2011 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................

More information

RPKA. Heat Pumps. Parts List 07-May-2014

RPKA. Heat Pumps. Parts List 07-May-2014 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................

More information

GEN20AD-GEN20AL-GEN18AN

GEN20AD-GEN20AL-GEN18AN AD-- Parts List 02-August-16 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-ad--.pdf for the current revision. Standby Generators Table of Contents

More information

K Page 1 of 48 Air Intake - Pg. 17

K Page 1 of 48 Air Intake - Pg. 17 K532-53168 Page 1 of 48 Air Intake - Pg. 17 Ref # Part Number Qty Description 24 25 041 06-S 1 Gasket, elbow 25 48 054 09 1 Elbow, air cleaner Discontinued not available at Kohler Co. 35 277116-S 1 Brace,

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0501 FOR USE WITH 95% MODELS: TG9S, GG9S (130,000 BTU ONLY) FOR USE WITH 80% MODELS: TG(8,L)S, GG(8,L)S (130,000

More information

CATALOGUE

CATALOGUE www.rotom.ca TOGU irdex Fan lades pplications Unitary ir onditioning eat Pumps and Ventilating 2 lade - eavy uty ondenser Type - Interchangeable ub Rotation iameter(") Pitch( ) lade epth (") 93-27702 W

More information

Crest Heating Boilers FBN(L) Series &

Crest Heating Boilers FBN(L) Series & Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 Series 100-101 & 110-111

More information

Installation Instructions

Installation Instructions 48011HW NATURAL GAS TO PROPANE CONVERSION KIT 58HDX, 359AAV, PG9YAB, PG9YAA Installation Instructions SAFETY REQUIREMENTS Installing and servicing heating equipment can be hazardous due to gas and electrical

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT ALPKT57- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... Table of Contents INSTALLATION

More information

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS Installation Instructions For Model Series *G7/*GC2 Furnaces and Appliances Using Honeywell Gas Valves. BEFORE THE CONVERSION

More information

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only Natural Gas High Altitude Conversion Kit United States Installations Only Installation Instructions Light Commercial Packaged Gas Electric Units R7TQ Series 6, - 7 1/2, & 10 Ton (2,001 FT - 10,000 FT)

More information

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet) Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet) INSTALLATION INSTRUCTIONS For R7 Series Light Commercial Packaged Gas Electric Units IIMPORTANT: Please

More information

Installation Instructions

Installation Instructions LP and High Altitude LP Gas Conversion Kit For United States Installations Installation Instructions For Model Series *G6/PGF1 Furnaces, *L1/PGC1 Furnaces, and *R4/PPG1 Gas/Electric Appliances using Honeywell

More information

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS 36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING

More information

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS Part No. 88847 Revised: August 2004 UNIVERSAL GAS FRYER Instruction Manual Model #8065NS Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS OPERATING INSTRUCTIONS UNPACKING AND ASSEMBLY After unpacking

More information

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction. ACCESSORY KIT INSTALLATION INSTRUCTIONS HIGH ALTITUDE APPLICATION CONVERSION MID-EFFICIENCY SINGLE-STAGE INDUCED COMBUSTION FURNACES MODELS: P*HU/G8T-UH/L8T-UH/FL8 UPFLOW / HORIZONTAL P*DN/G8T-DN/L8T-DN

More information

Installation Instructions For Natural Gas Conversion

Installation Instructions For Natural Gas Conversion Installation Instructions For Natural Gas Conversion (Kit Part No. 1175405) This kit is designed to convert PGX4 and PX4 Two -Stage Gas units for use with Natural Gas. Table 1 Heating Value at Altitude

More information

PARTS LIST. GF Sentry Series Infra-Red Salamander Broiler GFIR36C GFIR36 GFIR48 GFIR60. models. Parts & Service.

PARTS LIST. GF Sentry Series Infra-Red Salamander Broiler GFIR36C GFIR36 GFIR48 GFIR60. models. Parts & Service. GF Sentry Series Infra-Red Salamander Broiler models GFIR36C GFIR36 GFIR8 GFIR60 PARTS LIST Parts & Service T (USA & Canada): 800 7 6668 F (USA & Canada): 800 36 775 www.garland-group.com Garland Commercial

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Propane Gas Conversion Kit WGCK-1 Instructions for 0-6,000 Feet Elevation Installations This propane gas conversion kit is to be used only when converting the following furnace

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS 1NP0680 - PROPANE CONVERSION FOR USE WITH MODELS: PM8, PC8, PM9, PC9, FL9M, FL9C, FC9M, FC9C This conversion kit is to be installed by a qualified service agency

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS 00RX AND MSA HEAVY DUTY GAS GRIDDLES MODELS RX RX RX 0RX RX RX MSA MSA MSA MSA0 MSA MSA For additional information on Vulcan or to locate an authorized parts and service provider

More information

Natural Gas to L.P. Gas Conversion Kit

Natural Gas to L.P. Gas Conversion Kit Natural Gas to L.P. Gas Conversion Kit For Bosch 96% AFUE Gas Furnace, BGH96 Model Installation Instructions 3124627 2 Natural Gas to L.P. Gas Conversion Kit Installation Instructions Data subject to change

More information

Natural Gas to L.P. Gas Conversion Kit

Natural Gas to L.P. Gas Conversion Kit Natural Gas to L.P. Gas Conversion Kit For Bosch 80% AFUE Gas Furnace, BGS80 Model Installation Instructions 3124627 2 Natural Gas to L.P. Gas Conversion Kit Installation Instructions Data subject to change

More information

LENNOX SLP98UHV DIAGNOSTIC CODES

LENNOX SLP98UHV DIAGNOSTIC CODES Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST COMMERCIAL MODELS: 199 THRU 825 MODEL SIZES: 199, 260, 330, 400, 510. 625, 725, 825 MODEL TYPES: T, Ta, Tb, Tc, Td, Tx, WT, THWS, TIP, TIPR DATES OF MANUFACTURE: 08-01-81 THRU 09-30-82 MODELS: T, Ta, Tb,

More information

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel tapered design primary heat exchanger with crimped construction for long

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! INLET PRESS TAP WHITE-RODGERS 36E93-304 Delay-Opening Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information

ACCESSORY KIT INSTALLATION MANUAL

ACCESSORY KIT INSTALLATION MANUAL ACCESSORY KIT INSTALLATION MANUAL LP (PROPANE) CONVERSION KIT 1NP0366 FOR USE WITH MODELS: G8C & GF8 This conversion kit shall be installed by a qualified service agency in accordance with these instructions

More information

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1* INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1* THIS KIT CONTAINS: AOPS7741 (NATURAL TO PROPANE CONVERSION PARTS FOR MODEL SIZE, 50) AOPS7742(NATURAL

More information

User s Information Manual

User s Information Manual 48HC with EnergyX R System Factory Installed Energy Recovery Single---Package Rooftop Unit (RTU) Gas Heating/Electric Cooling Units 15 to 25 Nominal Tons with Puronr (R---410A) Refrigerant User s Information

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS Type 36C04, 36C14 Step-Opening Combination Gas Control (24 Volt, 120 Volt & 750 mv Models) INSTALLATI INSTRUCTIS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan CAST IRON BLOWERS MODEL CIW CATALOG 850 MAY 2012

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan CAST IRON BLOWERS MODEL CIW   CATALOG 850 MAY 2012 Twin City Fan INUSTRIL PROCESS N COERCIL VENTILTION SYSTES CST IRON BLOWERS OEL CIW CTLOG 850 Y 2012 CST IRON PRESSURE BLOWERS odel CIW Twin City Fan & Blower s CIW Cast Iron Pressure Blowers are the perfect

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 FOR USE WITH 90% MODELS: GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V, FC9V, GM9V,

More information

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY Form CP-UD-GC Obsoletes I-UD-GC (Version E) Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters General and Warnings All gas conversion must be done by a qualified

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 6C8-5 Combination Gas Control INSTALLATI INSTRUCTIS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS

More information

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel primary heat exchanger with crimped non-welded construction Stainless steel

More information

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT LENND 2004 Lennox Industries Inc. DaItas, Texas, USA GAS KITS & ACCESSORIES Litho U.S.A. 504,986M 11/2004 HIGH ALTITUDE KIT INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KIT (83M75) USED WITH G43UF & G51MP

More information

Installation Instructions

Installation Instructions CRNGELEV001A00 CRNGELEV002A00 CRLPELEV005A00 CRLPELEV006A00 CRLPKIT9001A00 LARGE ROOFTOP UNITS with R---410A ACCESSORY PROPANE and HIGH ALTITUDE GAS CONVERSION KIT GAS HEATING/ELECTRIC COOLING 15 to 25

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

36H SERIES Combination Gas Valve

36H SERIES Combination Gas Valve FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 36H series combination gas valve is

More information

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS INLET PRESS TAP WTE-RODGERS 36E96-314 DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL

More information

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED VULCAN 36RB 36IRB WOLF C36RB C36IRB This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 FOR USE WITH 90% MODELS: GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V, FC9V, GM9V,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS For Burner Kit replacement of 553010021 Burners in GUI, GDI & GNI Gas Furnaces Using Natural Gas Please read these instructions completely before attempting installation. SAFETY

More information

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS INLET PRESS TAP WHITE-RODGERS 36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS INLET PRESS TAP WTE-RODGERS 36E54-214 DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

Propane Conversion Kit Instruction

Propane Conversion Kit Instruction Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates Logamax plus GB62-80 kw 270,000 btu/hr Logamax plus GB62-00 kw 35,000 btu/hr This kit and instructions are for converting the

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS HIGH ALTITUDE APPLICATION CONVERSION INSTRUCTION HIGH EFFICIENCY GAS FURNACES 1PS0306 / 1PS0307 / 1PS0308 / 1PS0309 / 1PS0901 / 1PS0902 / 1PS0903 FOR USE WITH MODELS:

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 FOR USE WITH 90% + MODELS: GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V, FC9V, GM9V,

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS Type 36C67 Combination (24 Volt Models) INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING

More information

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33 INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33 FOR TWO-STAGE 90 PLUS DOWNFLOW/HORIZONTAL (-GTK) MODELS Recognize this symbol as an indication of Important Safety Information

More information

installation instructions

installation instructions installation instructions GAS CONVERSION KIT PROPANE-TO-NATURAL P/N 315572-71201 4GAD 6GAD Cancels: IIK 4G-50-4 IIK 4G-50-5 7/15/91 NOTE: Read the entire instructions before starting the installation.

More information

Installation Instructions

Installation Instructions CRNGELEV001A00 CRNGELEV002A00 CRLPELEV005A00 CRLPELEV006A00 CRLPKIT9001A00 PACKAGED ROOFTOP UNITS with R---410A ACCESSORY PROPANE and HIGH ALTITUDE GAS CONVERSION KIT GAS HEATING/ELECTRIC COOLING 176,000---400,000

More information

340/430 Truck Mount Parts Manual

340/430 Truck Mount Parts Manual 340/430 Truck Mount Parts Manual Table Of Contents Page Content 1 EXTERNAL BACK ILLUSTRATION 2 EXTERNAL BACK 3 MAIN HYDRAULIC DRIVE 4 BOTTOM REAR PTO DRIVE ASSEMBLY 5 REAR SPEED REDUCTION & TUMBLER DRIVE

More information

GAS FRYER Instruction Manual Model #5099NS

GAS FRYER Instruction Manual Model #5099NS Part No. 89932 Revised: March 2004 GAS FRYER Instruction Manual Model #5099NS Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS GAS FUNNEL CAKE FRYER 2 MODEL #5099NS GAS FUNNEL CAKE FRYER SAFETY PRECAUTIONS

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 36C53 Combination Gas Valves (24 Volt Model) INSTALLATI INSTRUCTIS Electrical Rating: Voltage: 24 Volts, (30 Volts Max.), 60 Hz. Current Rating: 0.23 Amps Type of Gas Natural Gas Pressure

More information

Rheem Spare Parts Manual Commercial gas model A Exterior 265L

Rheem Spare Parts Manual Commercial gas model A Exterior 265L Commercial gas model A631265 Exterior 265L 1 2 36 3 6 14 11 31 7 40 8 9 10 14 22 23 25 11 16 24 7 12 13 9 20 21 19 17 18 37 38 39 34 35 26 4 5 32 30 39 29 38 27 33 37 28 Commercial gas model A631265 Exterior

More information

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas Installation Instructions For Propane Gas Conversion (Kit Part No. 1173859) This kit is designed for conversion to Propane Gas Table 1 LP Gas Orifice Kits and Sizes Elevation Above Sea Level 0 to 2000

More information

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide SUMMITTM 400 & 600 Natural Gas Barbecues Step-By-Step Guide W E B E R W E B E R W E B E R W E B E R Summit 400 NG Summit 600 NG CANADIAN GAS ASSOCIATION R A P P R O V E D WARNING: Follow all leak check

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CTROL COULD CAUSE PERSAL INJURY AND/OR PROPERTY DAMAGE.

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this

More information

G96 Series BASOTROL Dual Operator Valve

G96 Series BASOTROL Dual Operator Valve Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without

More information

WARNING!! The attached Gold Medal Manual is for reference only and is not intended for any other purpose. The information contained in these on line manuals is subject to change at any time. Improvements

More information

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28 INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F13, RXGY-F27 AND RXGY-F28 FOR TWO-STAGE (GPL/GPR/GPE/GLL/GLR/GLE) MODELS Recognize this symbol as an indication of Important Safety Information THESE

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! Pilot Gas Outlet: Located at outlet end of the valve Type of Gas Suitable for all domestic heating gases Pressure Rating: 1/2 lb. per sq. in. Pressure Regulator Adjust Range (Typical, See Control Label):

More information

Propane Conversion Kit Instruction

Propane Conversion Kit Instruction Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates GB142-24 84,800 btu/hr GB142-30 106,000 btu/hr GB142-45 160,900 btu/hr GB142-60 214,800 btu/hr This kit and instructions are

More information

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models GAS VALVE RETROFIT KIT Pull Through Tube Heater Models DESCRIPTION: This kit is designed to replace existing Honeywell gas valves #VR8205P and #VR8205Q with White-Rodgers gas valves #36J23 and #36J58 respectively

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS PROPANE TO NATURAL GAS CONVERSION KIT NAHA00801NG or PART NO. 1183389 TABLE OF CONTENTS Safety Considerations... 1 Introduction... 1 Description and Usage... 2 Induced Combustion,

More information

Technical

Technical Control Settings SETTING Set point Range HOT Set point Differential ECO Limit Timings VALUE 90 F (32 C) to 160 F (71 C) 120 F (49 C) 15 F (9 C) 199 F (93 C) Notice the BLUE temperature adjustment knob.

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models DESCRIPTION These kits are designed to convert from one gas type to another (eg. from NATURAL to PROPANE or from PROPANE to NATURAL) when equipped with White-Rodgers DSI gas valves number 36J23 or 36J58.

More information

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302 SL 40-399 G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302 If converting from Propane to Natural Gas, order the Natural Gas Conversion Parts Kit (IBC Part # P-303) from your authorized IBC Distributor.

More information

LIST NO.E078 ENGINE. ENGINE BRUSH CUTTER Model CG 27EAS (E1)

LIST NO.E078 ENGINE. ENGINE BRUSH CUTTER Model CG 27EAS (E1) LIST E078 (E1) ENGINE ENGINE BRUSH CUTTER Model 2010 7 16 A B 1 2 1 3 4 5 6 7 16 15 17 13 8 9 10 11 12 13 14 15 18 19 20 11 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46

More information

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41 INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41 FOR MODULATING DOWNFLOW/HORIZONTAL AND DEDICATED HORIZONTAL MODELS (-GGD, -GGE, -GGF)! Recognize this symbol

More information

Technical

Technical Control Settings SETTING Set point Range HOT Set point Differential ECO Limit Timings TECHNICAL SERVICE DEPARTMENT VALUE 90 F (32 C) to 160 F (71 C) 120 F (49 C) 15 F (9 C) 199 F (93 C) Notice the BLUE

More information

Propane Conversion Kit Instruction

Propane Conversion Kit Instruction Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates GB42-24 84,800 btu/hr Tab. GB42-30 06,000 btu/hr GB42-45 49,000 btu/hr GB42-60 24,800 btu/hr This kit and instructions are

More information

Air Intake Snorkel Kit

Air Intake Snorkel Kit SSV KIT - Air Intake Snorkel Kit Part number (SKU) : 715003733 Product: Side-by-side Project no: 487802499 Instruction Sheet P/N: 487802499 Revision no: Revision date: Item covered: Air Intake Snorkel

More information

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08 Parts Manual STRIKER 2840 Striker 2840 Parts List - PN 238155 - Printed in USA 03/18/08 Standard Parts Recommended General Wear Parts Ref No Part Description Qty Part No 1 Squeegee Hose Assembly

More information

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L Commercial gas model A631265 Exterior 265L Commercial gas model A631265 Exterior 265L Item Part No. Description 1 221735 Foam cover 2 221914 Anode x 3 (black) 1153mm 2 221924 Anode x 3 (blue) 1153mm 3

More information

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning

More information

INSTALLATION GUIDE Gas Rangetops

INSTALLATION GUIDE Gas Rangetops INSTALLATION GUIDE Gas Rangetops Contents Wolf Gas Rangetops........................... 3 Safety Instructions............................ 4 Gas Rangetop Specifications.................... 5 Gas Rangetop

More information

SUMMITTM 475 & 675. Natural Gas Barbecues. Step-By-Step Guide THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.

SUMMITTM 475 & 675. Natural Gas Barbecues. Step-By-Step Guide THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY. SUMMITTM 475 & 675 Natural Gas Barbecues Step-By-Step Guide Summit 475 NG THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY. Summit 675 NG THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY. CANADIAN

More information

INSTALLATION & OPERATING INSTRUCTIONS FOR THE DS300 BRAZING HEARTH FLAMEFAST (UK) LIMITED

INSTALLATION & OPERATING INSTRUCTIONS FOR THE DS300 BRAZING HEARTH FLAMEFAST (UK) LIMITED INSTALLATION & OPERATING INSTRUCTIONS FOR THE DS300 BRAZING HEARTH FLAMEFAST (UK) LIMITED Unit 2. Labtec Street. Swinton. Manchester M27 8SE Telephone 0161 793 9998. Fax 0161 793 0098 www.flamefast.co.uk.

More information