This parts list is current as of the above revision date. See for the current revision.
|
|
- Holly Casey
- 6 years ago
- Views:
Transcription
1 Parts List This parts list is current as of the above revision date. See for the current revision. Condensing Units
2 Table of Contents Model Explanation Page 3 Parts Numbers Drawings/Photographs Panels - Miscellaneous Page 4 Electrical Group Page 5 Fan Group Page 6 Coil Parts Page 7 Coil Parts Page 8 Compressor Group Page 9 Compressor Group Page 10 Compressor Group Page 11 Accessories Page 12 Exploded View Page 13 Control Box Assembly Page 14 Notes/Disclaimer Page 15 Page 2 of
3 NUMBER EXPLANATION R A K A J A Z (1) (2) (3) (4) (5) (6) (7) (8) (1) TRADEBRAND IDENTIFICATION (6) J = /1/60 (2) C = /3/60 A = Condensing Unit D = 460/3/60 Y = 575/3/60 (3) TYPE T = /1/50 N = /3/50 (4) DESIGN SERIES / VARIATION (7) VARIATIONS (5) COOLING CAPACITY A = Standard Model = 18,000 BTU/HR = 24,000 BTU/HR (8) COMPRESSOR = 30,000 BTU/HR Z = Scroll w/sweat Connections = 36,000 BTU/HR S = Reciprocationg w/sweat Connection = 36,000 BTU/HR = 42,000 BTU/HR = 48,000 BTU/HR = 60,000 BTU/HR SERIAL NUMBER EXPLANATION M (1) (2) (3) (4) (5) (1) COMPRESSOR IDENTIFICATION NUMBER (2) PRODUCTION LOCATION F = Ft. Smith, AR M = Milledgeville, GA (3) WEEK OF PRODUCTION (4) YEAR OF PRODUCTION (5) PRODUCTION NUMBER Page 3 of
4 No. Notes COOLING CAPACITY SHEET METAL PARTS, MISCELLANEOUS 1 Base Pan AE AE AE AE Cabinet AE AE AE AE Grille AS AS AS AS Venturi AE AE AE AE Access Panel AE AE AE AE Control Box (w/o components) AE AE AE AE Service Valve - Liquid See Coil Group 10 Service Valve - Suction See Coil Group Capacitor Adaptor Plate (2 in. round capacitor) AE AE AE AE Capacitor Adaptor Plate (2 in. X 1-1/4 in. oval capacitor) AE AE AE AE Touch-up Paint (Aerosol) Touch-up Paint (Paint Pens) No. Notes COOLING CAPACITY SHEET METAL PARTS, MISCELLANEOUS 1 Base Pan AE AE AE AE Cabinet AE AE AE AE Grille AS AS AS AS Venturi AE AE AE AE Access Panel AE AE AE AE Control Box (w/o components) AE AE AE AE Service Valve - Liquid See Coil Group 10 Service Valve - Suction See Coil Group Capacitor Adaptor Plate (2 in. round capacitor) AE AE AE AE Capacitor Adaptor Plate (2 in. X 1-1/4 in. oval capacitor) AE AE AE AE Touch-up Paint (Aerosol) Touch-up Paint (Paint Pens) Page 4 of
5 / / / / / ELECTRIC GROUP 15 Stk Contactor Capacitor - Fan Motor/Compressor See Compressor Group 17 Time Delay Relay See Compressor Group / ELECTRIC GROUP 15 Stk Contactor Capacitor - Fan Motor/Compressor See Compressor Group 17 Time Delay Relay See Compressor Group ELECTRIC GROUP 15 Stk Contactor Capacitor - Fan Motor/Compressor See Compressor Group 17 Time Delay Relay See Compressor Group / / ELECTRIC GROUP 15 Stk Contactor Capacitor - Fan Motor See Fan Group 17 Time Delay Relay See Compressor Group / / / ELECTRIC GROUP 15 Stk Contactor Capacitor - Fan Motor See Fan Group 17 Time Delay Relay See Compressor Group ELECTRIC GROUP 15 Stk Contactor Capacitor - Fan Motor See Fan Group 17 Time Delay Relay See Compressor Group ELECTRIC GROUP 15 Stk Contactor Capacitor - Fan Motor See Fan Group 17 Time Delay Relay See Compressor Group Page 5 of
6 / / / / / FAN GROUP 8 Stk Fan Motor Capacitor - Compressor/Fan Motor See Compressor Group 7 Stk Fan Blade / / FAN GROUP 8 Stk Fan Motor Capacitor - Compressor/Fan Motor See Compressor Group 7 Stk Fan Blade FAN GROUP 8 Stk Fan Motor Capacitor - Compressor/Fan Motor See Compressor Group 7 Stk Fan Blade / / / FAN GROUP 8 Stk Fan Motor Stk Capacitor - Fan Motor Stk Fan Blade / / / FAN GROUP 8 Stk Fan Motor Stk Capacitor - Fan Motor Stk Fan Blade FAN GROUP 8 Stk Fan Motor Stk Capacitor - Fan Motor Stk Fan Blade FAN GROUP 8 Stk Fan Motor Stk Capacitor - Fan Motor Stk Fan Blade Page 6 of
7 9 Service Valve - Liquid Service Valve - Suction (See Note 2) Stk High Pressure Control N/A N/A Stk Low Pressure Control N/A N/A N/A Stk Condenser Coil AS AS AS AS AS AS Piston - Flowcheck N/A N/A N/A N/A N/A Stk Filter Drier Service Valve - Liquid Service Valve - Suction Stk High Pressure Control N/A N/A Stk Low Pressure Control N/A N/A Stk Condenser Coil AS AS AS AS AS Piston - Flowcheck N/A N/A N/A N/A Stk Filter Drier Service Valve - Liquid Service Valve - Suction Stk High Pressure Control Stk Condenser Coil AS AS AS AS AS AS Piston - Flowcheck N/A N/A Stk Filter Drier Service Valve - Liquid Service Valve - Suction Stk High Pressure Control N/A N/A Stk Low Pressure Control N/A N/A 14 Stk Condenser Coil AS AS AS AS Stk Filter Drier Low Ambient Control N/A N/A 9 Service Valve - Liquid Service Valve - Suction Stk High Pressure Control N/A Stk Low Pressure Control N/A N/A N/A 14 Stk Condenser Coil AS AS AS AS AS AS Piston - Flowcheck N/A N/A N/A Stk Filter Drier Page 7 of
8 9 Service Valve - Liquid Service Valve - Suction Stk High Pressure Control Stk Low Pressure Control Stk Condenser Coil AS AS AS AS Stk Filter Drier Service Valve - Liquid Service Valve - Suction Stk High Pressure Control N/A Stk Low Pressure Control N/A 14 Stk Condenser Coil AS AS AS AS Stk Filter Drier Stk Low Ambient Control N/A 9 Service Valve - Liquid Service Valve - Suction Stk High Pressure Control N/A Stk Low Pressure Control N/A Stk Condenser Coil AS AS AS AS Stk Filter Drier Stk Low Ambient Control N/A N/A Service Valve - Liquid Service Valve - Suction Stk High Pressure Control N/A N/A Stk Low Pressure Control N/A N/A N/A N/A 14 Stk Condenser Coil AS AS AS AS Piston - Flowcheck N/A N/A N/A Stk Filter Drier Page 8 of
9 Compressor ID: Stk Compressor S See Note S S S 16 Stk Capacitor - Compressor/Fan Crankcase Heater N/A N/A 17 Stk Time Delay Relay N/A N/A N/A Start Relay N/A N/A N/A N/A N/A Start Capacitor N/A N/A N/A N/A N/A Sound Enclosure N/A N/A N/A Compressor ID: Stk Compressor See Note S S 16 Stk Capacitor - Compressor/Fan Crankcase Heater N/A N/A 18 Start Relay N/A N/A N/A N/A N/A Start Capacitor N/A N/A N/A N/A N/A Sound Enclosure N/A N/A N/A Compressor ID: Stk Compressor See Note S S 16 Stk Capacitor - Compressor/Fan Crankcase Heater N/A N/A 18 Start Relay N/A N/A N/A N/A Start Capacitor N/A N/A N/A N/A Sound Enclosure N/A N/A N/A Compressor ID: Stk Compressor Stk Capacitor - Compressor/Fan Crankcase Heater Sound Enclosure Compressor ID: Stk Compressor Stk Capacitor - Compressor/Fan Crankcase Heater Sound Enclosure Compressor ID: Stk Compressor Stk Capacitor - Compressor/Fan Compressor ID: Stk,1 Compressor (See Note 1) S S 16 Stk Capacitor - Compressor/Fan Compressor ID: Stk Compressor Stk Capacitor - Compressor/Fan Compressor ID: Stk Compressor S 16 Stk Capacitor - Compressor/Fan Page 9 of
10 Compressor ID: Stk Compressor S 16 Stk Capacitor - Compressor/Fan Crankcase Heater N/A N/A N/A N/A 17 Time Delay Relay N/A N/A N/A Start Relay N/A N/A N/A N/A 19 Start Capacitor N/A N/A N/A N/A Sound Enclosure N/A N/A N/A N/A Compressor ID: Stk Compressor S S S Stk Capacitor - Compressor/Fan Crankcase Heater N/A N/A N/A N/A 17 Time Delay Relay N/A N/A N/A N/A PTCR Module (Start Assist) N/A N/A N/A N/A 18 Start Relay N/A N/A N/A 19 Start Capacitor N/A N/A N/A Sound Enclosure N/A N/A N/A N/A Compressor ID: Stk Compressor S 16 Stk Capacitor - Compressor/Fan Crankcase Heater N/A N/A 18 Start Relay N/A N/A 19 Start Capacitor N/A N/A Sound Enclosure N/A N/A Muffler AE N/A Compressor ID: Stk Compressor S S S S S 17 Time Delay Relay N/A Compressor ID: Stk Compressor S S S S 17 Time Delay Relay N/A N/A N/A N/A Muffler N/A N/A N/A N/A N/A Compressor ID: Stk Compressor S Time Delay Relay N/A Muffler Compressor ID: Stk Compressor S S S S Stk Capacitor - Compressor/Fan N/A N/A N/A N/A Time Delay Relay N/A N/A N/A N/A N/A Muffler N/A N/A Compressor ID: Stk Compressor S Muffler N/A Page 10 of
11 / / Compressor ID: Stk Compressor S S S S 16 Stk Capacitor - Compressor/Fan N/A N/A 12 Crankcase Heater N/A N/A N/A N/A Crankcase Heater Control N/A N/A N/A N/A 17 Time Delay Relay Start Relay N/A N/A N/A N/A Start Capacitor N/A N/A N/A N/A Compressor ID: Stk Compressor S S S Stk Capacitor - Compressor/Fan N/A 12 Crankcase Heater N/A N/A N/A Start Relay N/A N/A N/A N/A Start Capacitor N/A N/A N/A N/A 17 Time Delay Relay N/A N/A N/A N/A PTCR Module (Start Assist) N/A N/A N/A N/A Compressor ID: Stk Compressor S Stk Capacitor - Compressor/Fan Crankcase Heater Control N/A 17 Time Delay Relay Start Relay N/A Start Capacitor N/A Compressor ID: Stk Compressor S 16 Stk Capacitor - Compressor/Fan Compressor ID: Stk Compressor Stk Capacitor - Compressor/Fan Compressor ID: Stk Compressor S 16 Stk Capacitor - Compressor/Fan / Compressor ID: Stk Compressor S S S 17 Time Delay Relay N/A N/A N/A Compressor ID: Stk Compressor S S S S Crankcase Heater Control N/A N/A N/A N/A N/A 17 Time Delay Relay N/A N/A Compressor ID: Stk Compressor S Stk Capacitor - Compressor/Fan N/A N/A N/A N/A Compressor ID: Stk Compressor S S Compressor ID: Stk Compressor S Page 11 of
12 No. Notes COOLING CAPACITY - ALL ACCESSORIES Time Delay Control (3-phase models only) RXMD-B01 Low Ambient Control RXAD-A04 High Pressure Control RXAB-A03 Low Pressure Control RXAC-A03 Page 12 of
13 Exploded View Page 13 of
14 Control Box Assembly Page 14 of
15 NOTES Stk It is recommended that stock be maintained for this part. N/A Not Applicable was also used until date codes F0295 or M0295 under Compressor ID For Compressor ID 5881, use for Service Valve (Suction). 3 This unit was built with a scroll compressor. However, no scroll compressor is currently available that can physically fit within the cabinet enclosure. Therefore, this compressor should be replaced with reciprocating compressor S. Repiping is required to replace the original scroll with a reciprocating compressor. DISCLAIMER: This document is intended to provide general replacement parts information to aid qualified service personnel in the repair of these models. The complete Model and Serial Number of the unit under repair should be specified when selecting and ordering replacement parts. Specifications and illustrations are subject to change without notice. Document supersedes all previous parts lists for these models. See for the latest revision of this document. The manufacturer assumes no obligation for errors or omissions. Service personnel must verify the proper and safe operation of equipment after the replacement of any original components. P.O. Box Fort Smith, AR
This parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................
More informationRPNK. Heat Pumps. Parts List 25-July-2011
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................
More informationRPLA. Heat Pumps. Parts List 19-July-2011
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................
More informationRPKA. Heat Pumps. Parts List 07-May-2014
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................................................................
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps - Commercial Table of Contents Model Explanation...................................................................................................................
More informationRPMD. Heat Pumps. Parts List 02-October-2017
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of ontents Model Explanation...................................................................................................................
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. ondensing Units Table of ontents Model Explanation...................................................................
More informationUPNE. Heat Pumps. Parts List 19-July-2011
Parts List 19-uly-2011 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-.pdf for the current revision. Heat Pumps Table of ontents Model Explanation...................................................................
More informationMAINLINE MLA14 AIR CONDITIONERS
FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured
More informationGEN20AD-GEN20AL-GEN18AN
AD-- Parts List 02-August-16 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-ad--.pdf for the current revision. Standby Generators Table of Contents
More informationMODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners
15.5 MODEL: SA13 Air Conditioners FORM NO. ASC-221 REV. 1 Sure Comfort SA13 Air Conditioners Efficiencies 13-15.5 S/11.5-13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.
FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz. Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.
FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7
More informationNordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units)
IMI CORNELIUS INC. www.cornelius.com Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units) Publication Number: 631806058 Revision Date: October 13, 2009 Revision: E Visit the
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz. Units Date 1/09 Table Of Contents This parts list contains
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.
FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to
More information4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP
4HP15 PRODUCT SPECIFICATIONS 15 SPLIT SYSTEM HEAT PUMP FORM NO. 4HP15-100 (12/2017) FEATURES AND BENEFITS R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for
More informationThis parts list is current as of the above revision date. See for the current revision.
RK arts ist This parts list is current as of the above revision date. See http://www.rheempartslists.net/.pdf for the current revision. ackage ir Conditioners - Commercial Table of Contents odel Explanation...................................................................................................................
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationMHS BY(Y)
-(Y) Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807--(Y) Table
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationRuud Achiever Series Heat Pump
Heat Pumps Ruud Achiever Series Heat Pump Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationRuud Achiever Series Heat Pump
Heat Pumps Ruud Achiever Series Heat Pump RP14**F Series Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper
More informationAIR CONDITIONERS WA14**W SERIES
FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationAIR CONDITIONERS WA14 SERIES
FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationMHS BY(D)
003-010() Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807-003-010()
More informationThis parts list is current as of the above revision date. See for the current revision.
RKK Parts ist This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-rkk.pdf for the current revision. Package Gas-Electric - Commercial Table of Contents
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: up to 14 SEER/11.5 EER/8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing
More informationRheem Classic Series Heat Pump
Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14 SEER/11.5 EER 8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and
More informationInstallation Instructions
32LT900301 32LT900611 32LT901247 32LT901647 SMALL ROOFTOP S ACCESSORY MOTORMASTERR I HEAD PRESSURE CONTROLLER 3to10TONS Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 PACKAGE USAGE-
More informationMAINLINE MLP14**A HEAT PUMPS
FORM NO. PML-806 REV. 2 Supersedes Form No. PTZ-789 MAINLINE HEAT PUMPS Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to
More information4SCU13 PRODUCT SPECIFICATIONS
4SCU PRODUCT SPECIFICATIONS PHASE SPLIT SYSTEM AIR CONDITIONER FORM NO. 4SCULC-00 (0/07) coil ifice shipped with outdo unit f optimum efficiency and capacity Charged f 5 ft. of line set Trade available
More informationGM Series Dual-Block Multi-Function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series
More informationDEALER DIRECT WARRANTY MANUAL
DEALER DIRECT WARRANTY MANUAL Table of Contents Extended Warranty Purchase Process... 3 Extended Warranty Order Form Instruction Guide... 4 Extended Warranty Order Form... 5 Warranty Regisration Process...
More informationRAYPAK ILLUSTRATED PARTS LIST
COMMERCIAL MODELS: XFYRE 300 THROUGH 850 CATALOG NO. 9300.79 Effective: 10-05-18 Replaces: 09-15-17 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 300, 400, 500, 700 & 850 MODEL TYPES: MODULATING CONDENSING
More informationAE R1 February 2015
February 2015 CoreSense Diagnostics for Copeland Scroll UltraTech Air Conditioning Compressors TABLE OF CONTENTS Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to
More informationRheem Classic Series Two Stage Heat Pump
Heat Pumps Rheem Classic Series Two Stage Heat Pump Efficiencies: 15-16 SEER/11.5-13 EER Nominal Sizes 2, 3, 4 and 5 Ton [7.03, 10.6, 14.06 and 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7
More information4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS
PRODUCT SPECIFICATIONS 16 S SPLIT SYSTEM ENHANCED AIR CONDITIONING FORM NO. -100 (06/2014) DESIGN Designed for ambients up to 125 F COMPONENTS Service valves positioned for quick installation and easy
More informationProduct Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)
CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE Product Data (3619, 4823, 6025) A06009 A07904 The CAPMP and CARMP evaporator coils incorporate proven standards for reliable system operation and
More informationSupersedes: RP1(495) Form RP1 (1102)
RENEWAL PARTS CENTRIFUGAL LIQUID CHILLERS Supersedes: 0.9-RP(9) Form 0.9-RP (0) UNIT COMPONENTS MODEL YK (STYLES A & B) WITH MICROCOMPUTER CONTROL CENTER PART #3-000-00 FOR ELECTRO-MECHANICAL STARTER &
More informationELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATIONS AIR CONDITIONERS EL16XC1 ELITE Series R-410A Bulletin 210758 November 2017 Supersedes August 2017 SEER up to 17.90 1.5 to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh MODEL NUMBER
More informationGuideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society
Guideline No.M-05(201510) M-05 AIR COMPRESSOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable technical requirements
More informationCopeland Discus with CoreSense Diagnostics January 2011
Copeland Discus with CoreSense Diagnostics January 2011 Slide 1 1/27/2011 5:48 PM Discus with CoreSense Diagnostics Case Studies Supermarket In Columbus, Ohio Saves $4,500 With Discus with CoreSense Diagnostics
More informationVARIABLE SPEED AIR CONDITIONERS
FORM NO. AFJ-224 Supersedes Form No. AFJ-222 VARIABLE SPEED AIR CONDITIONERS FO*20C SERIES Efficiencies up to 20 SEER/13 EER Nominal Sizes 2, 3, 4 & 5 Ton [7.03, 10.6, 14.06 & 17.6 kw] Cooling Capacities
More informationHigh Pressure Breathing Air Compressors
High Pressure Breathing Air Compressors [ Full variety for different applications] MSA offers a comprehensive range of high pressure breathing air compressors for both the firefighting and diving market,
More informationAE R4. December Copeland Scroll Compressors for CO 2 Subcritical Refrigeration (R-744)
December 2017 Copeland Scroll Compressors for CO 2 Subcritical Refrigeration (R-744) TABLE OF CONTENTS Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of Electrical
More informationApplication Engineering Bulletin AE-1301 Issued June, Copeland APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A
4-1301 Application Engineering Bulletin AE-1301 Issued June, 1996 APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A Introduction The new model family of "ZP" compressors is designed for
More informationAE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions
AE19-1132 R8 December 2004 Reformatted November 2010 Copelametic Two-Stage Compressors Application and Service Instructions The Copeland two stage compressors have been developed to efficiently achieve
More informationService Parts Manual Drawer Microwave Models: MWD24-2 & MWD30-2
Service Parts Manual 28 14 40 49 68 29 73 5 11 55 38 75 56 4 44 8 7 45 1 52 2 22 10 46 50 71 25 26 62 15 27 3 24 48 9 39 57 13 63 39 74 36 64 51 53 50 6 35 66 42 70 21 18 37 55 16 17 76 60 33 67 19 54
More informationModel 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.
EVAPORATOR COILS A COIL UNCASED R 22 or R 410A SYSTEMS 1 5 Tons WEAU Certification applies only when the complete system is listed with ARI ISO 9001:2000 REGISTERED R 410A R 22 Size Shipping Weight Size
More informationFSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities
TECHNICAL SPECIFICATIONS FSH1BG Series FEATURES and BENEFITS Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities 1 The iq Drive heat pump system features modulating compressor
More informationInstallation Instructions
Installation Instructions Low-Ambient Pressure Switch KSALA0201R22 KSALA0301410 NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,
More informationApplication Guideline. R410A Air Conditioning Scroll
Application Guideline R410A Air Conditioning Scroll Contents 1 Introduction 2 Nomenclature 3 How a Scroll Works 4 Application Considerations 4.1 Accumulators 4.2.1 Crankcase Heaters Single Phase 4.2.2
More informationAC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight
Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this
More informationRG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free
TM Refrigerant Recovery Machine RG6000 1 Operating Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Safety Precautions WARNING
More informationSYSCO ST JOHN'S MOUNT PEARL, NEWFOUNDLAND
SYSCO ST JOHN'S MOUNT PEARL, NEWFOUNDLAND October, 2016 Infrared Inspection Report Sysco St. John s 10 Old Placentia Road Mount Pearl, NF A1N 4P5 Company Contact: David Shaw Project: C261016 2605 CHARTER
More informationUniflair LE TDAR-TUAR
Uniflair LE TDAR-TUAR Direct Expansion air-cooled units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDAR) >
More informationField Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.
Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.
More informationTWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3
TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning
More informationInstallation Instructions
Low -Ambient Pressure Switch 0201R22 0301410 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,
More informationProduct Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES
CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationSequence of Operations
MAGNUM Condensing Unit Software 5580 Enterprise Pkwy. Fort Myers, FL 33905 Office: 239-694-0089 Fax: 239-694-0031 Sequence of Operations MAGNUM Chiller V8 software www.mcscontrols.com MCS Total Solution
More informationSPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.
2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or
More informationMODELS YLAA YLAA0175 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A
AIR-COOLED SCROLL CHILLERS RENEWAL PARTS Supersedes: 50.72-RP (80) Form 50.72-RP () MODELS YLAA0070 - YLAA075 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A GS5608 R-0A 70-75 TON 60 Hz Issue Date: January,
More informationOPERATOR, ORGANIZATIONAL, DIRECT AND GENERAL SUPPORT AND DEPOT MAINTENANCE MANUAL COMPRESSOR, RECIPROCATING, AIR; 15 CFM, 175 PSI;
TM 5-4310-339-15 D E P A R T M E N T O F T H E A R M Y T E C H N I C A L M A N U A L OPERATOR, ORGANIZATIONAL, DIRECT AND GENERAL SUPPORT AND DEPOT MAINTENANCE MANUAL COMPRESSOR, RECIPROCATING, AIR; 15
More informationASERCOM guidelines for the design of multiple compressor racks using frequency inverters
ASERCOM guidelines for the design of multiple compressor racks using frequency inverters Contents 1 SCOPE AND PURPOSE 2 SELECTION OF COMPRESSORS 3 DESIGN FEATURES 4 CONTROL FEATURES 5 STABILITY OF WORKING
More informationMODELS YCAL0287, 0317, 0347 and YCAL0377 STYLE "C"
AIR-COOLED CONDENSING UNIT HERMETIC SCROLL RENEWAL PARTS Supercedes: NONE Form: 150.64-RP2 (105) MODELS YCAL0287, 0317, 0347 and YCAL0377 STYLE "C" YCALMMHPd 90-135 TON 270-457Kw 50 Hz 380/415-3-50 MODELS
More informationRIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]
RIX COMPRESSORS MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230 November 21, 2002 APPLICABILITY [ A] INTRODUCTION Safety This electromechanical equipment is designed to produce high pressure gas.
More informationUniversal Valve Company Inc
Universal Valve Company Inc 800-223-0741 www.universalvalve.com 1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Free Air Universal
More informationUniversal Valve Company Inc
1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Universal Air Towers Please read closely to identify the components that are
More informationSpare parts list ( ) Spare parts list HDS 990
Spare parts list (5.952-855.0) Spare parts list HDS 990 13.10.2014 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 990 (5.952-855.0)... 6 10 Individual parts... 7 49 Spare
More informationProduct Data. CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil --- Cased and Uncased Upflow, Downflow CAPVP / CARVP
CAPVP, CARVP, CAPVU, CARVU Evaporator Coil A Coil Cased and Uncased Upflow, Downflow Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationLENNOX SLP98UHV DIAGNOSTIC CODES
Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second
More informationSoft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II
Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II Stephen Li Daikin / Goodman Manufacturing Jan. 2016 1 2 Test objectives See the impact of R-32 on air
More informationModel Series 62 Constant Differential Relay
Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant
More informationSpare parts list ( ) Spare parts list HD 1090 WS *
Spare parts list (5.955-706.0) Spare parts list HD 1090 WS * 26.01.2015 www.kaercher.com EN Table of contents Spare parts list HD 1090 WS * (5.955-706.0)... 6 10 Individual parts... 7 11 Individual parts...
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationCROT-6 CROT-10 CRO-4. for Compressor Overload Protection
May 2010 / RACE Catalogue 90-10 UK for Compressor Overload Protection CROT-6 Listed and y Certified 400 psig Maximum Rated Pressure CROT-10 Listed and Certified 400 psig Maximum Rated Pressure CRO-4 Recognized
More informationSnow Pushers AP-SSP1572, AP-SSP1584, AP-SSP1596, & AP-SSP PK Parts Manual. Copyright 2018 Printed 07/11/18
Snow Pushers AP-SSP1572, AP-SSP1584, AP-SSP1596, & AP-SSP2596 37732 303-348PK Parts Manual Read the Operator's Manual entirely. When you see this symbol, the subsequent instructions and warnings are serious
More informationGAS COMPRESSION SYSTEM
GAS COMPRESSION SYSTEM The gas compression system at HI 376 A consists of two natural gas turbine-driven Compressors (CBA-4020/4070). Both Compressors are needed for the volume of gas being compressed.
More informationCrankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................
More informationVibration Related Testing for Hermetic Compressor Development
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1978 Vibration Related Testing for Hermetic Compressor Development J. P. Elson Follo this
More informationUser s Information Manual
48HC with EnergyX R System Factory Installed Energy Recovery Single---Package Rooftop Unit (RTU) Gas Heating/Electric Cooling Units 15 to 25 Nominal Tons with Puronr (R---410A) Refrigerant User s Information
More informationK Page 1 of 48 Air Intake - Pg. 17
K532-53168 Page 1 of 48 Air Intake - Pg. 17 Ref # Part Number Qty Description 24 25 041 06-S 1 Gasket, elbow 25 48 054 09 1 Elbow, air cleaner Discontinued not available at Kohler Co. 35 277116-S 1 Brace,
More informationJORDAIR/BAUER Service Manual
JORDAIR/BAUER Service Manual Breathing Air Compressor Maintenance Log Doc. ServiceManual Page - 1 SAFETY RELEASE-2016 The following document is prepared to ensure safety of operators and service technicians.
More informationAIR SYSTEM TABLE 1 SPECIAL COMPRESSOR SYSTEM DISCHARGE PRESSURE REQUIREMENTS TYPE. M.P. 1.0 mfa(s) (140 psis) oil free PNGS - Self lubricated
Mechanical Equipment - Course 430.1 AR SYSTEM Compres..'ed air is a major source of industrial power with many advantages. t is relatively safe, economical, easily transmitted and adaptable. ts adaptability
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationSkid Snow Pushers. SSP15 & SSP25 Series P Parts Manual. Copyright 2017 Printed 11/28/17
Skid Snow Pushers SSP15 & SSP25 Series 37009 303-348P Parts Manual Read the Operator's Manual entirely. When you see this symbol, the subsequent instructions and warnings are serious - follow without exception.
More informationMPS-003AG-005AG
003- Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807-003- Table
More informationAll technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI
PACIFIC MX NITROX BREATHING AIR according to DIN EN 12021 MAX OXYGEN 40% DELIVERY l/min 600 m 3 h 36 PRESSURE BAR 225 PSI 3250 Quality system certified to iso 9001 BREATHING AIR is a product line that
More informationOC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)
by Supera Anesthesia Innovations USER'S GUIDE OC4000 OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY I O : ON (power switched on) : OFF (power switched off) : Class II protection : Do not expose to open flames
More informationSpare parts list ( ) Spare parts list HDS 5.0/30 S-4 Eh
Spare parts list (5.970-508.0) Spare parts list HDS 5.0/30 S-4 Eh 21.05.2012 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 5.0/30 S-4 Eh (5.970-508.0)... 6 10 Housing
More informationRefrigeration Scroll For Parallel Applications
Refrigeration Scroll For Parallel Applications Application Guideline 1 Scroll Compressors in Parallel for Refrigeration Applications 1. Introduction The concept of parallel operation for refrigeration
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS C3, C4, C5 Uncased Indoor Coils (RepLcoil) 2 3/8" 1 3/8" 12 1/8" H 14 1/2" 19 1/2" 2 1/2" W "A" Coil Features Anteater Coil Technology: The Anteater TM coil is made with Uniguard
More informationSpare parts list. ( ) Spare parts list HD 3.0/20 C Ea
Spare parts list (5.972-551.0) Spare parts list HD 3.0/20 C Ea 20.04.2016 www.kaercher.com EN Table of contents Order instructions Spare parts list HD 3.0/20 C Ea (5.972-551.0) 10 Housing 20 Pump set 21
More informationAIR COOLED SCREW WATER CHILLERS
GENERAL ELECTRIC AIR COOLED SCREW CHILLERS R-134a AASC Series AASC055B thru AASC445B 55 TR thru 445 TR 194 thru 1565 GE_AASC_Series.indd 1 3/26/12 5:20 PM GE_AASC_Series.indd 2 3/26/12 5:20 PM CONTENTS
More informationTroubleshooting Guide. Pg. 1
Troubleshooting Guide Pg. 1 Introduction to Automotive HVAC: Introduction to an AC System Review of AC System and components. Pg. 2 Troubleshooting: AC system Components AC System and its Components Receiver/
More informationInstructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.
027R9782 Instructions Control Solution ICF 20-4, ICF 25-4, ICF 32-4. ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position ICF xx-4 ICF xx-6 ICF xx-4 / ICF xx-6 with ICM ICM 027R9782
More information