1 RENEWAL PARTS CENTRIFUGAL LIQUID CHILLERS Supersedes: 0.9-RP(9) Form 0.9-RP (0) UNIT COMPONENTS MODEL YK (STYLES A & B) WITH MICROCOMPUTER CONTROL CENTER PART # FOR ELECTRO-MECHANICAL STARTER & SOLID STATE STARTER R- & R3A COOLING ONLY 03A

2 TABLE OF CONTENTS FORM 0.9-RP (0) NOMENCLATURE... UNIT COMPONENTS...3 UNIT SHELLS... EVAPORATOR TUBES...8 CONDENSER TUBES...8 ORIFICE PLATE...9 OIL PUMP STARTER OVERLOAD ELEMENTS...0 CURRENT TRANSFORMER KIT...0 TRANSFORMER ONLY...0 INLET CHILLED WATER STRAINER... NEOPRENE VIBRATION ISOLATORS... SPRING ISOLATORS... MISCELLANEOUS AND ACCESSORIES... PAGE NOMENCLATURE YK N N H CX A DESIGN LEVEL (A) POWER SUPPLY for 0 Hz for 0 Hz COMPRESSOR G, H0, H, H, J, J, J3, J CONDENSER L, L, M, M, N, N, P, P, Q, Q, R, R, S, S EVAPORATOR L, L, M, M, N, N, P, P, Q, Q, R, R, S, S MOTOR 0 Hz 0 Hz CH CX CE CT CJ CY CF CU CK CZ CG CV CL CA CH CW CM CB CI CX CN DA CJ DA CP DB CK DB CR DC CL DC CS DD CM DD CT DE CN DE CU DF CO OF CV DH CP OG CW DJ CQ OH CR OJ CS MODEL

3 FORM 00.9-RP (0) UNIT COMPONENTS ITEM NO. DESCRIPTION QUAN./ UNIT REF. FIG Oil Cooler Valve Solenoid Valve, Thermostat Valve, Ball - 3/" Valve, Ball - " Valve, Ball - /" Valve, Stop, Angle - /" Valve, Stop, Angle - /" Valve, Stop, Angle - 3/8" Valve, Stop Angle - /" Dehydrator, Filter Drier Strainer - /" Male Flare Strainer - /8" Female Eductor, Oil Return Valve, Relief Valve, Stop, Dual Relief Filter, Oil A Filter Element Valve, Stop - 3/" Gasket, 3 3/" O.D. x /8" I.D Eductor, Oil Return Starter, Oil Pump Control, H.P. Cutout Gasket - Oil Return Line Gasket - Orifice Plate N N, N N, P P, P P Q Q, Q Q, R R, R R, S S, S S Gasket - Discharge Connection G3, G, H0 & H Compressor H, J & J Compressor J3 & J Compressor Gasket - Suction/Evaporator G3, G, H0, H & H Compressor J & J Compressor J3 & J Compressor Gasket - Compressor Suction G3, G, G0, H & H Compressor J & J Compressor J3 & J Compressor Gasket - Refrigerant Line N N, N N, P P, P P Q Q, Q Q, R R, R R, S S, S S Sight Glass, Evaporator

4 FORM 0.9-RP (0) FIG FIG - 93

5 FORM 00.9-RP (0) FIG - LD088 FIG 3 - LD0880 FIG - 9 FIG - LD088

6 FORM 0.9-RP (0) FIG - LD0883

7 FORM 00.9-RP (0) UNIT SHELLS FIG 8 - LD088 EVAPORATOR EVAPORATOR WITH STANDARD COMPACT WATER BOXES GASKET PASS PASS 3 PASS REQ'D. L 8 M 8 N 3 P 3 Q R S 9 EVAPORATOR GASKET REQ'D. 8 3 / 8 3 / 3 3 / / 9 / EVAPORATOR WITH MARINE WATER BOXES GASKET GASKET PASS PASS 3 PASS REQ'D. L 3 M 3 N P Q 8 R S GASKET REQ'D. / / GASKET REQ'D / 3 / 9 REQ'D

8 FORM 0.9-RP (0) CONDENSER WITH STANDARD COMPACT WATER BOXES CONDENSER WITH MARINE WATER BOXES COND. PASS PASS GASKET GASKET REQ. REQ. COND. PASS PASS GASKET GASKET REQ. REQ. L 9 9 L 38 9 M 9 M 3 N 3 3 / N 3 3 P / P 3 Q Q 3 0 R R 0 S 3 3 S 8 8 EVAPORATOR TUBES CONDENSER TUBES EVAPORATOR TUBE NO. CONDENSER TUBE NO. REQ'D REQ'D L L L L M M M M N N N N P P P P Q Q Q Q R R R R S S S S

9 FORM 00.9-RP (0) ORIFICE PLATE CONDENSER L, M,N, & P ORIFICE PLATE CONDENSER Q, R, & S ORIFICE PLATE

10 FORM 0.9-RP (0) OIL PUMP STARTER OVERLOAD ELEMENTS (QUAN. 3 PER UNIT) OIL PUMP VOLTAGE 08, 0, 30, , , 00, , ,, KIT CURRENT TRANSFORMER FIELD INSTALLED ELECTRO-MECHANICAL STARTERS ONLY MOTOR VOLTAGE 08/00 300/0 FLA "CT" RATIO - 00: : : : : : : : : 3--0 TRANSFORMER ONLY "CT" RATIO 00: : : :

11 FORM 00.9-RP (0) STRAINER, INLET CHILLED WATER (COMPACT HEADS AND MARINE WATER BOXES) COOLER PASS NOZZLE SIZE L M N P Q R S SYSTEM OPERATING WEIGHT NEOPRENE VIBRATION ISOLATORS ISOLATORS, NEOPRENE PAD SIZE,3 to 8,83 LBS /" x " ( x cm) 8,83 to 3,30 LBS " x " ( x cm) 3,3 to 00, LBS " x 8" ( x 8 cm) SYSTEM OPERATING WEIGHT SPRING ISOLATORS ISOLATORS, SPRING NO. OF SPRINGS,880 to 30,8 LBS ,8 to 3,009 LBS ,00 to,39 LBS ,0 to 8,39 LBS ,30 to,9 LBS ,30 to 89,30 LBS

12 FORM 0.9-RP (0) MISCELLANEOUS AND ACCESSORIES COMPOUND DESCRIPTION QUANTITY Compound, Heat Conductive (For Thermometer Wells) oz. Can TOUCH-UP PAINTS - SPRAY CANS DESCRIPTION Caribbean Blue Enamel Black (Control Center) Purchase Locally FLOW SWITCH CONTROL DESCRIPTION 0 DWP DWP TEMPERATURE RECORDER HZ 0 0 DESCRIPTION NO. OF PENS ACCESSORY CONTROL PARTS DESCRIPTION Kit Condenser Water Sensors Card File (remote and Temperature Setpoint) Cards (Remote Current and Temperature Setpoint) P.O. Box 9, York, Pennsylvania USA 0-9 Copyright by York International Corporation 00 Form 0.9-RP (0) Supersedes: 0.9-RP (9) Tele Subject to change without notice. Printed in USA ALL RIGHTS RESERVED

NOTE: Inserted Literature Supplement - YT Style "J" Chillers New Style Oil Filter/"O"-Ring

NOTE: Inserted Literature Supplement - YT Style J Chillers New Style Oil Filter/O-Ring MILLENNIUM TM CENTRIFUGAL LIQUID CHILLERS RENEWAL PARTS Supersedes: 160.48-RP5(LS2)(800) UNIT COMPONENTS MODEL YT STYLE J Form 160.48-RP6 (501) NOTE: Inserted Literature Supplement - YT Style "J" Chillers

More information

CENTRIFUGAL COMPRESSORS

CENTRIFUGAL COMPRESSORS CENTRIFUGAL COMPRESSORS RENEWAL PARTS Supersedes: 60.49-RP2 (27) Form 60.49-RP2 (37) COMPRESSOR MODEL YDHA-36 and LHA-36 YDHA-4 and LHA-4 YDHA-46 and LHA-46 YPHA-50N and LHA-50N YDHA-50W and LHA-50W HA-57,

More information

MODEL YR T0 - T3 MOD LEVEL A-C. 200 thru 430 tons (60 hz) 170 thru 365 tons (50 hz) 600 thru 1280 KW (50 hz)

MODEL YR T0 - T3 MOD LEVEL A-C. 200 thru 430 tons (60 hz) 170 thru 365 tons (50 hz) 600 thru 1280 KW (50 hz) MODEL YR T0 - T3 MOD LEVEL A-C ROTARY SCREW LIQUID CHILLERS renewal parts Supersedes: 160.81-RP5 (710) Form 160.81-RP5 (1113) 200 thru 430 tons (60 hz) 700 thru 1500 Kw (60 HZ) 170 thru 365 tons (50 hz)

More information

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions AE19-1132 R8 December 2004 Reformatted November 2010 Copelametic Two-Stage Compressors Application and Service Instructions The Copeland two stage compressors have been developed to efficiently achieve

More information

Model YD Style A-B Unit Components

Model YD Style A-B Unit Components Centrifugal Liquid Chillers Renewal Parts Supersedes: 160.69-RP2 (313) Form 160.69-RP2 (915) Model YD Style A-B Unit Components R-134a LD09115 Issue Date: September 15, 2015 IMPORTANT! READ BEFORE PROCEEDING!

More information

REFRIGERATION SYSTEM COMPONENTS

REFRIGERATION SYSTEM COMPONENTS REFRIGERATION SYSTEM COMPONENTS henrytech.com Conventional Oil Separators The function of an Oil Separator is to remove oil from the discharge gas and return it to the Compressor either directly or through

More information

MODELS YLAA YLAA0175 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A

MODELS YLAA YLAA0175 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A AIR-COOLED SCROLL CHILLERS RENEWAL PARTS Supersedes: 50.72-RP (80) Form 50.72-RP () MODELS YLAA0070 - YLAA075 DESIGN SERIES A, B & C DEVELOPMENT LEVEL A GS5608 R-0A 70-75 TON 60 Hz Issue Date: January,

More information

MODELS YCAS0373, 0403, 0453, 0503, 0543, 0573, 0623, and YCAS0653 STYLE "G"

MODELS YCAS0373, 0403, 0453, 0503, 0543, 0573, 0623, and YCAS0653 STYLE G AIR-COOLED SCREW LIQUID CHILLERS RENEWAL PARTS New Release Form: 20.9-RP2 (204) MODELS YCAS0373, 0403, 0453, 0503, 0543, 0573, 0623, and YCAS0653 STYLE "G" 02897-G 24-22 TON 270-457Kw 50 Hz 380/45-3-50

More information

MODELS YCAL0287, 0317, 0347 and YCAL0377 STYLE "C"

MODELS YCAL0287, 0317, 0347 and YCAL0377 STYLE C AIR-COOLED CONDENSING UNIT HERMETIC SCROLL RENEWAL PARTS Supercedes: NONE Form: 150.64-RP2 (105) MODELS YCAL0287, 0317, 0347 and YCAL0377 STYLE "C" YCALMMHPd 90-135 TON 270-457Kw 50 Hz 380/415-3-50 MODELS

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................

More information

CHECK VALVES APPLICATIONS

CHECK VALVES APPLICATIONS 45 APPLICATIONS The check valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97//EC, Article 1, Section 2.1.4 and are subject of Article

More information

Water Cooled Condensing Units

Water Cooled Condensing Units Bulletin 502.4A March 2003 (Replaces 502.4 3/02) Water Cooled Condensing Units SWN - Semi-Hermetic Compressor Water Cooled Condensing Units Table of Contents Nomenclature... 2 Features & Benefits...3-4

More information

CM MBC & CM MBC PARTS LIST

CM MBC & CM MBC PARTS LIST 8650 Enterprise Drive, Peosta IA 52068 319-556-7484 / Fax 319-556-1235 CM-1500-0MBC & CM-1503-1MBC Engine Oil Grade: Engine Oil Capacity: Pump Oil Grade: Pump Oil Capacity: Nozzle Size: PARTS LIST (After

More information

RPLA. Heat Pumps. Parts List 19-July-2011

RPLA. Heat Pumps. Parts List 19-July-2011 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................

More information

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger) IB-77 Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger) These installation, operation and technical instructions should be used by experienced personnel as a

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps - Commercial Table of Contents Model Explanation...................................................................................................................

More information

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................

More information

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP Danfoss Expansion Valves T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP Code Model Connections Danfoss No Internally Equalised F500 TX2 R22 3/8 x 1/2 flare 068Z3206 F502

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL GS2000 / GS2001 OIL-LESS REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01099 GS2000.DOC NRP-OM-GS2000

More information

TON MODELS 50 HERTZ STYLE D

TON MODELS 50 HERTZ STYLE D Millennium TM AIR COOLED SCREW LIQUID CHILLERS AIR COOLED SCREW HERMETIC INSTALLATION, OPERATION, MAINT. Supersedes: Nothing FORM 201.10-NM2 (696) 105-215 TON MODELS 50 HERTZ STYLE D #27960 With EPROM

More information

RPNK. Heat Pumps. Parts List 25-July-2011

RPNK. Heat Pumps. Parts List 25-July-2011 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................

More information

MAINLINE MLA14 AIR CONDITIONERS

MAINLINE MLA14 AIR CONDITIONERS FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured

More information

RPKA. Heat Pumps. Parts List 07-May-2014

RPKA. Heat Pumps. Parts List 07-May-2014 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................................................................

More information

Semi-Hermetic compact screw compressors

Semi-Hermetic compact screw compressors CX Series Frascold CX compact screw compressors range has been designed to grant the maximum efficiency, reliability and flexibility. Currently the range consists of 566 models, which cover not only a

More information

Section 3- Repair and Calibration Procedures

Section 3- Repair and Calibration Procedures Section 3- Repair and Calibration Procedures 1. Refrigerant Removal Procedures 2. Scale/PC Board Recalibration Procedure 3. PC Board Configuration Procedure of AR400 4. Scale Tare Procedure 5. Gauge Calibration

More information

LIEBERT DS TOP VIEW FRONT VIEW. This document has been generated on 22 September :18 PM (EST). Dry Weight (approximate) lb.

LIEBERT DS TOP VIEW FRONT VIEW. This document has been generated on 22 September :18 PM (EST). Dry Weight (approximate) lb. " 88mm 5" 889mm CBINET DIMENSIONL DT DS DOWNFLOW IR COOLED 5-77kW (15-22 TONS) W/ SCROLL OR DIGITL SCROLL COMPRESSOR MODELS Secondary Refrigerant Piping Entrance 80" 202mm Opening IR INLET OPENING 2 /8"

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No. FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7

More information

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES 110 AIR CONDITIONING CHILLED WATER PLANT 1. Ensure power to water chiller controller and all fan coil unit controllers is on 2. Ensure chilled water expansion tank level is at its proper level 3. Ensure

More information

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz. SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz. Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239

More information

Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units)

Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units) IMI CORNELIUS INC. www.cornelius.com Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units) Publication Number: 631806058 Revision Date: October 13, 2009 Revision: E Visit the

More information

An Overview: 5000 MW Ultramega Solar Park at Dholera. For the positive response to Expression of Interest (EoI)

An Overview: 5000 MW Ultramega Solar Park at Dholera. For the positive response to Expression of Interest (EoI) An Overview: 5000 MW Ultramega Solar Park at Dholera For the positive response to Expression of Interest (EoI) Outline Location Plant Capacity. Status of the project Modalities of implementation of Solar

More information

FSW SECTION. Product guide. Shut Off Valves, Vibration Eliminators, Accumulators & Oil Separators D SECTION. 55

FSW SECTION. Product guide. Shut Off Valves, Vibration Eliminators, Accumulators & Oil Separators D SECTION.   55 FSW Product guide D SECTION Shut Off Valves, Vibration Eliminators, Accumulators & Oil Separators For more information visit www.fsw.uk.com 55 Danfoss Check Valves (Non-return) Danfoss non-return valves

More information

Refrigeration Scroll For Parallel Applications

Refrigeration Scroll For Parallel Applications Refrigeration Scroll For Parallel Applications Application Guideline 1 Scroll Compressors in Parallel for Refrigeration Applications 1. Introduction The concept of parallel operation for refrigeration

More information

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz. SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz. Units Date 1/09 Table Of Contents This parts list contains

More information

PEM-EX-C. Figure: PEM-EX-C*A*G. ka054000en; Rev. 2.7 J

PEM-EX-C. Figure: PEM-EX-C*A*G. ka054000en; Rev. 2.7 J PEM-EX-C J2013329 Figure: PEM-EX-C*A*G Robust and safe pressure transducer for general mining applications In combination with a Kirchgaesser multi channel signal converter and display unit COMBA-EX or

More information

CO 2 radial piston compressor (transcritical)

CO 2 radial piston compressor (transcritical) CO 2 radial piston compressor (transcritical) At a glance Operating limits and performance data Technical data Dimensions and connections Scope of supply 124 126 129 130 131 Radial piston compressor (transcritical)

More information

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS EL16XC1 ELITE Series R-410A Bulletin 210758 November 2017 Supersedes August 2017 SEER up to 17.90 1.5 to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh MODEL NUMBER

More information

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 Data sheet Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 The CCMT is an electrically operated valve designed specifically for operation in CO 2 systems. The CCMT valve concept is

More information

YCAS STYLE D

YCAS STYLE D INSTALLATION, OPERATION, & MAINTENANCE Millennium AIR COOLED SCREW LIQUID CHILLERS AIR COOLED SCREW HERMETIC Supersedes: Nothing Form 201.10-NM3 (798) YCAS 310-380 STYLE D 28508(r)A MASTER SLAVE YCAJ 3

More information

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet Capacity regulator (hot gas bypass), type TUH/TCHE/ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

Geometric Style Die Head Chasers

Geometric Style Die Head Chasers Geometric Style Die Head Chasers REGULAR EXTENDED OFFSET REGULAR STYLE "K" STYLE "K" ESSENTIALS: The following pages list Geometric style die head chasers in many popular diameter and pitch combinations.

More information

Capacity regulator (hot gas bypass)

Capacity regulator (hot gas bypass) MAKING MODERN LIVING POSSIBLE Capacity regulator (hot gas bypass) TUH/TCHE/ Technical brochure Contents Page Introduction........................................................................................3

More information

Reliable System Performance PM valves

Reliable System Performance PM valves MAKING MODERN LIVING POSSIBLE Service manual Reliable System Performance PM valves Danfoss components are designed to give a high level of performance over an extended operating life. When Danfoss develops

More information

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Name of Property: Address: Phone Number: Inspector: Contract No.: Date: This Report Covers: Monthly Quarterly Annual Other

More information

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

COMPRESSOR REPLACEMENT PROCEDURE (R-134A) 372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 COMPRESSOR REPLACEMENT PROCEDURE (R-134A) [ ] If possible operate the compressor with proper charge for 5 minutes

More information

The CWE / HWE-R Series: Overview. Frame and cabinet covering

The CWE / HWE-R Series: Overview. Frame and cabinet covering Table Of Contents The CWE / HWE-R Series: Overview...... 1 Frame and cabinet covering... 1 Refrigerant gas...... 2 Compressors...... 2 Condensers...... 2 Fans... 3 Evaporator...... 3 Refrigerant circuit......

More information

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system Bulletin 061013 TCR-104 & 109 Filling and adding to the Glycol pressure system 1. Glycol System and air On this model the glycol system is a closed system, the glycol is not exposed to the air. No external

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands)

Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands) Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands) The key reasons why MRO Facility now requires 5,000 PSI Hydraulic Test Stand are as follows: 1) New generation commercial aircraft

More information

CNG FILLING STATIONS

CNG FILLING STATIONS CNG FILLING STATIONS GAS INLET 3/4 F EXIT CNG TO CAR TANK 5 mt / 16 feet HOSE AND FILLING NOZZLE REMOTE ELECTRIC PANEL THREE-PHASE height 40 cm / 15.7 width 30 cm / 11.8 depth 20 cm / 7.8 EQUIPPED WITH

More information

Crest Heating Boilers FBN(L) Series &

Crest Heating Boilers FBN(L) Series & Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 Series 100-101 & 110-111

More information

Float valves Types SV 4, SV 5 and SV 6

Float valves Types SV 4, SV 5 and SV 6 Data sheet Float valves Types SV 4, SV 5 and SV 6 SV 4-6 are for use on the low pressure side as modulating liquid level regulators in refrigeration, freezing and air conditioning systems with ammonia

More information

80% Less installation time with just two welds for fast and efficient installation.

80% Less installation time with just two welds for fast and efficient installation. The smarter, faster route to Installation and service The ICF Valve Station - member of the Flexline family. The unique ICF Flexline valve station allows you to substitute your traditional valve train

More information

RP series Rotor Pumps

RP series Rotor Pumps ontact etails RP series Rotor Pumps Nomenclature Features Low noise Substantial reduction of the operation noise, by to db (comparison with aikin products), and improved sound quality are achieved by adopting

More information

Thermostatic Expansion

Thermostatic Expansion Thermostatic Expansion Valves Thermostatic Expansion Valves TCCE Series Application TCCE thermostatic expansion valve is used to regulate refrigerant flow into the evaporator, especially in applications

More information

Case 12 Multistage Centrifugal Refrigeration System Halocarbon Refrigerant

Case 12 Multistage Centrifugal Refrigeration System Halocarbon Refrigerant Case 12 Multistage Centrifugal Refrigeration System Halocarbon Refrigerant Copy Right By: Thomas T.S. Wan 温 ) April 15, 2011 All Rights Reserved Case Background: This case is to show how to achieve the

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No. FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to

More information

Product Sheet Spraymist Unit

Product Sheet Spraymist Unit Product Sheet Spraymist Unit DESCRIPTION The Spraymist unit is perfectly adapted for use with differents liquids for applications as metalcutting, drilling, grinding, cooling or wetting processes and chain

More information

Refrigeration and Air Conditioning Technical leaflet

Refrigeration and Air Conditioning Technical leaflet Refrigeration and Air Conditioning Technical leaflet Technical leaflet Injection valve type 2 Introduction Danfoss has developed a injection valve type 2 for desuperheating in 2-stage refrigeration systems

More information

Selection of ICF made easy Save even more time with ICF

Selection of ICF made easy Save even more time with ICF MAKING MODERN LIVING POSSIBLE Selection of ICF made easy Save even more time with ICF ICF stands for valve trains and for over five years installation and service has never been easier. This quick guide

More information

Pump On Demand. Skimmer System

Pump On Demand. Skimmer System Pump On Demand Skimmer System POD (Pump on Demand) Skimmer System Application Out-of-the-box LNAPL recovery in 2-inch and larger-diameter wells. The POD Skimmer model TR-610 recovers light-end hydrocarbons

More information

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction...3 Features...3 Technical data...4 Ordering...4 Sizing...5 Valve selection...5

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No. FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7

More information

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Differential pressure switch / Lube oil protection control MP 54 and MP 55 Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors

More information

CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature

CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature Thermostats CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature Description The CTC 1000 series room thermostats are for use in HVAC systems for the control of pneumatic valves and

More information

Linde Cryogenics. Helium Recovery Systems.

Linde Cryogenics. Helium Recovery Systems. Linde Cryogenics. Helium Recovery Systems. 02 Contents. 3 Introduction 4 Recovery Compressor Options 6 Installation Recovery Piping and Fittings Kits 6 Model 500A Automatic External Helium Purifier 7 Purity

More information

Frascold semi-hermetic compact screw compressors

Frascold semi-hermetic compact screw compressors CX Frascold semi-hermetic compact screw compressors for refrigeration, air conditioning, heat pump, process cooling v3 2 CX Series Frascold CX compact screw compressors range has been designed to grant

More information

) for different types of systems Test of contact function The correct pressure control for your system

) for different types of systems Test of contact function The correct pressure control for your system Contents Page Installation....................................................................................... 21 Placing of surplus capillary tube...................................................................

More information

AE R1 February 2015

AE R1 February 2015 February 2015 CoreSense Diagnostics for Copeland Scroll UltraTech Air Conditioning Compressors TABLE OF CONTENTS Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to

More information

Compresor lg de BTU modelo QP325KCB

Compresor lg de BTU modelo QP325KCB Compresor lg de 24000 BTU modelo QP325KCB Compresor lg de 24000 BTU modelo QP325KCB Ref. No. LGETA-140115-1576 Issued Date 2014.01.15 0.Revision History Rev. No. Rev. 0 Rev. Date - Data Rev. No Rev. description

More information

14. Exploded View. Page 68

14. Exploded View. Page 68 14. Exploded View Page 68 15. View of housing Page 69 11. Spare Parts HY05 HY13 55 E-2124010 Keys for safety, set=2pc. 54 E-2124012 Safety lock incl. 2 keys 1 B-3204031 1 B-2204101 1 B-2204111 1 2 B-2204105

More information

Model 3600-R410A. Part No Instruction Operation & Maintenance

Model 3600-R410A. Part No Instruction Operation & Maintenance Model 3600-R410A Part No. 2000-3600 Instruction 2079-0140 Operation & Maintenance Rev. G September 2007 WARNING: INHALATION OF HIGH CONCENTRATIONS OF REFRIGERANT VAPORS IS HARMFUL AND MAY CAUSE HEART IRREGULARITIES,

More information

Pilot valves for pilot operated servo valves

Pilot valves for pilot operated servo valves Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)

More information

Installation Instructions

Installation Instructions Installation Instructions Low-Ambient Pressure Switch KSALA0201R22 KSALA0301410 NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,

More information

BGA158 Series CE Approved Class A Shutoff Gas Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that

More information

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Solenoid valves, two-step on/off PMLX REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning

More information

RecoverXLT2-AP Oil-Less Universal Refrigerant Recovery System Operation and Maintenance Manual

RecoverXLT2-AP Oil-Less Universal Refrigerant Recovery System Operation and Maintenance Manual RecoverXLT2-AP Oil-Less Universal Refrigerant Recovery System Operation and Maintenance Manual (English) Table of Contents General Safety Instructions 2-3 RecoverXLT2-AP Operation Guide Direct Liquid Recovery

More information

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

Workhorse 8 Oxygen System Model No 5665, 5673, 5679 11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse 8 Oxygen System Model No 5665, 5673, 5679 Part Number 1815 Revision B SeQual Technologies San Diego, CA USA Cautions,

More information

Pressure maintenance systems with compressors

Pressure maintenance systems with compressors Pressure maintenance systems with compressors Compresso Pressure maintenance systems with compressors Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING AVANTAGE Compresso

More information

Liquid level regulating valves Types PMFL / PMFH and SV

Liquid level regulating valves Types PMFL / PMFH and SV Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve

More information

2016 /17 Catalog. distributed exclusively throughout the U.S by

2016 /17 Catalog. distributed exclusively throughout the U.S by BALL VALVES/SEACOCKS Ball Valve ½ NPS 90659 2211 Ball Valve ¾ NPS 90660 2228 Ball Valve 1 NPS 90661 2235 Ball Valve 1¼ NPS 90662* 2242 Ball Valve 1½ NPS 90663 2259 Ball Valve 2 NPS 90664 2266 THRU-HULL

More information

COMPRESSOR MANUAL. (888)

COMPRESSOR MANUAL.   (888) COMPRESSOR MANUAL www.ultimadentalsystems.com (888) 900-8584 Table of Contents Introduction..Page 2 Quick Compressor Start Guide....Page 3-5 Compressor Pump Diagram....Page 6 Compressor Frame Diagram....Page

More information

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology Airless-Spraying Equipment SuperFinish31 Fully equipped More power Innovative QLS technology New technology, fully equipped with even more power. This is the new SuperFinish 31 Airless spraying equipment,

More information

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3

More information

RecoverXLT Oil-Less Universal Refrigerant Recovery System. (For serial numbers and higher)

RecoverXLT Oil-Less Universal Refrigerant Recovery System. (For serial numbers and higher) RecoverXLT Oil-Less Universal Refrigerant Recovery System Operation and Maintenance Manual (For serial numbers 181195 and higher) (English and Spanish. French and German available at www.yellowjacket.com)

More information

TRADE : REFRIGERATION MECHANIC (COMMERCIAL)

TRADE : REFRIGERATION MECHANIC (COMMERCIAL) INDUCTION ID1 Recall applicable sections of the Manpower Training (Act No 56, 1981), with special reference to discipline and legal responsibilities. Pass a questionnaire with at least 80%. ID2 Recall

More information

R-410A 50% R-32 50% R-125.

R-410A 50% R-32 50% R-125. R-410A R-410A Facts Ozone friendly- No Chlorine Replacement for R-22, NOT a drop in! Higher Pressure Range-50 to 75% higher than R-22 Requires Special Lubricants R-410A It s a Blended Refrigerant. 50%

More information

ACCESSORIES FOR LANCASTER PUMPS & WATER SYSTEMS INDEX

ACCESSORIES FOR LANCASTER PUMPS & WATER SYSTEMS INDEX PAGE 1 ACCESSORIES FOR LANCASTER PUMPS & WATER SYSTEMS INDEX ADAPTERS PAGE OFFSET CASING ADAPTER 2 PITLESS ADAPTER 2 ROPE ADAPTER 4 VENTURI MALE ADAPTER 2 AIR VALUME CONTROL AIR VALVES 2 CABLE SUBMERSIBLE

More information

Float valves Types SV 1 and SV 3

Float valves Types SV 1 and SV 3 Data sheet Float valves s SV 1 and SV 3 The SV 1 and 3 can be used separately as a modulating liquid level regulator in refrigerating, freezing and air conditioning systems for ammonia or fluorinated refrigerants.

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex

More information

Pressure switches for air and water CS

Pressure switches for air and water CS Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II

Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II Stephen Li Daikin / Goodman Manufacturing Jan. 2016 1 2 Test objectives See the impact of R-32 on air

More information

System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner

System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner Mohammad Khawaldeh Director, Unitary & Applied Product Units Presentation Outline Objectives Challenges Base

More information

WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL YCRL REMOTE CONDENSER SCROLL LIQUID CHILLERS STYLE A (60 HZ) TONS 175KW THROUGH 597KW

WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL YCRL REMOTE CONDENSER SCROLL LIQUID CHILLERS STYLE A (60 HZ) TONS 175KW THROUGH 597KW WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL INSTALLATION, OPERATION, MAINTENANCE Supersedes 150.27-NM1 (915) Form 150.27-NM1 (1115) 035-22148-101 YCRL0064-0198 REMOTE CONDENSER SCROLL LIQUID CHILLERS

More information

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO 400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand

More information

Sample C ylinde rs, Acce ssorie s, and O utage Tube s

Sample C ylinde rs, Acce ssorie s, and O utage Tube s www.swagelok.com Sample C ylinde rs, cce ssorie s, and O utage s Features Sizes from 10 to 3785 cm 3 (1 gal) Working pressures up to 5000 psig (344 bar) 304L and 316L stainless steel and alloy 400 2 Sample

More information

High Pressure Breathing Air Compressors

High Pressure Breathing Air Compressors High Pressure Breathing Air Compressors [ Full variety for different applications] MSA offers a comprehensive range of high pressure breathing air compressors for both the firefighting and diving market,

More information

Application Engineering Bulletin AE-1301 Issued June, Copeland APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A

Application Engineering Bulletin AE-1301 Issued June, Copeland APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A 4-1301 Application Engineering Bulletin AE-1301 Issued June, 1996 APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A Introduction The new model family of "ZP" compressors is designed for

More information