ANION SELF-REGENERATING SUPPRESSOR 300 (ASRS 300 (4-mm), P/N ) (ASRS 300 (2-mm), P/N )

Size: px
Start display at page:

Download "ANION SELF-REGENERATING SUPPRESSOR 300 (ASRS 300 (4-mm), P/N ) (ASRS 300 (2-mm), P/N )"

Transcription

1 ASRS 300 CSRS 300

2 SRS 300 Product Manual Page 1 of 50 PRODUCT MANUAL FOR THE ANION SELF-REGENERATING SUPPRESSOR 300 (ASRS 300 (4-mm), P/N ) (ASRS 300 (2-mm), P/N ) CATION SELF-REGENERATING SUPPRESSOR 300 (CSRS 300 (4-mm), P/N ) (CSRS 300 (2-mm), P/N ) Dionex Corporation, 2008 Document No Revision 06 August 2008

3 SRS 300 Product Manual Page 2 of 50 TABLE OF CONTENTS 1. INTRODUCTION Self-Regenerating Suppressor Overview of Suppression Modes Mode of Operation Selection The AutoSuppression Recycle Mode The AutoSuppression External Water Mode The Chemical Suppression Mode The MPIC Suppression Mode INSTALLATION System Requirements Self-Regenerating Suppressor Control Reagent-Free Controller (RFC) Back Pressure Coils for the SRS Assembly Gas Separator Waste Tube for the SRS Assembly Self-Regenerating Suppressor Current Selection Calculating the Optimum Current Setting OPERATION Chemical Purity Requirements Inorganic Chemicals Solvents Deionized Water Start-up Hydration Back Pressure Coil Pressure Test Quick Back Pressure Check Plumbing for the AutoSuppression Recycle Mode Operation Eluent Flow Path Connections in the AutoSuppression Recycle Mode Regenerant Flow Path Connections in the AutoSuppression Recycle Mode Installation in Thermal Chamber Installation in ICS Plumbing for the AutoSuppression External Water Mode Operation Eluent Flow Path Connections for the AutoSuppression External Water Mode Regenerant Flow Path Connections in the AutoSuppression External Water Mode Regenerant Flow Path Connections in the AutoSuppression External Water Mode with Peristaltic Pump Installation in Thermal Chamber Installation in ICS Plumbing for Chemical Suppression Mode Operation Plumbing for MPIC Suppression Mode Operation Eluent Flow Path Connections in MPIC Suppression Mode Regenerant Flow Path Connections in MPIC Suppression Mode Using Pressurized Water Delivery System MPIC Suppression Mode Operation Self-Regenerating Suppressor (SRS 300) Storage Short Term Storage (1 to 5 days) Long Term Storage (More than 5 days) TROUBLESHOOTING GUIDE Self-Regenerating Suppressor Operational Status Displays Alarm State Small or Increasing Analyte Peak Areas Suppressor Regeneration Steps Full or Extended Regeneration: High Background Conductivity Drifting Baseline Noisy Baseline Decreased Sensitivity System Back Pressure Increases Over Time Liquid Leaks Poor or unstable recovery of certain peaks Peaks and spikes in the absence of an injection... 34

4 SRS 300 Product Manual Page 3 of SELF-REGENERATING SUPPRESSOR CLEANUP Metal Contaminants or Precipitates Organic Contaminants APPENDIX A - CURRENT SETTINGS...37 A.1. Optimum Current Settings for Common Eluents; ASRS 300 (4 and 2 mm) A.2 Optimum Current Settings for Common Eluents; CSRS 300 (4 and 2 mm) A.3 Current Settings for Older Detectors APPENDIX B - SUPPRESSOR CONTROLLER...42 B.1 SRS Control for the CD20/CD25/CD25A and ED40/ED50/ED50A (DX-500 instruments) B.1.1 SRS Control for the DX B.1.2 SRS Control for the CDM-3/PED-2 (DX-300 Instruments) B.1.3 SRS Control for the DX-100 (Model DX 1-03) B.1.4 SRC Controller APPENDIX C - ALARM STATES FOR OLDER INSTRUMENTS...47 C.1 Alarm States for the CD20/ED40 (DX-500 Instruments) C.1.1 Alarm States for the DX C.1.2 Alarm States for The CDM-3 and PED-2 (DX-300 Instruments), DX-100 (Model 1-03) and SRC ATTACHMENT - SRS 300 QUICKSTART...49

5 SRS 300 Product Manual Page 4 of INTRODUCTION 1.1. Self-Regenerating Suppressor The Self-Regenerating Suppressor (SRS 300) replaces the ULTRA II suppressor product line. The SRS 300 is redesigned with exterior hardware changes that allow the suppressor to be more pressure tolerant than previous generation suppressor devices. The SRS 300 continues to use cleaned ion exchange components (gasketed screens and membranes) as the ULTRA II suppressor devices. The 2mm ASRS 300 replaces the ASRS MS suppressor product and should be used for anion Mass Spectrometry (MS) Applications. The Self-Regenerating Suppressor 300 (SRS 300) is available in two versions: the Anion Self-Regenerating Suppressor 300 (ASRS 300) or Cation Self-Regenerating Suppressor 300 (CSRS 300). The SRS 300 system consists of a Self-Regenerating Suppressor, the SRS Control, the back pressure coils, and the Gas Separator Waste Tube. This high performance, low maintenance AutoSuppression system provides a reliable solution for Ion Chromatography. Additionally, the SRS 300 offers high capacity suppression while adding minimal dead volume to the analytical system. The ASRS 300 provides continuous suppression of traditional eluents, and more concentrated eluents up to 200 mm NaOH. The CSRS 300 offers continuous suppression of concentrated eluents up to 100 mn H 2 SO 4 or MSA. This high capacity significantly expands the capabilities and simplifies the operation of Ion Chromatography. The SRS 300 is available in both 2-mm and 4-mm formats for use with 2, 3, 4, or 5-mm Ion Chromatography columns and systems. The 2-mm SRS 300 is specially designed with reduced internal volume to ensure optimum performance with 2-mm columns and systems. In fact, the suppression capacity of the 2-mm version is greater than the 4-mm version due to the reduced eluent flow rate and proportionally greater surface area. Anion Self-Regenerating ) Suppressor (ASRS 300 Waste Gas Separator Waste Tube 1/ Coil # Coi #1 l Back Pressure Coils or 1/4-28 Figure 1 The Self-Regenerating Suppressor Assistance is available for any problem during the shipment or operation of Dionex products through the Dionex North America Technical Call Center at DIONEX-0 ( ) or through any of the Worldwide Dionex Offices on the Reference Library CD-ROM.

6 SRS 300 Product Manual Page 5 of 50 The SRS 300 design comprises of two regenerant chambers and one eluent chamber separated by ion exchange membranes. Regenerant flow chambers and an eluent flow chamber are defined by the gasketed screens. The eluent flows countercurrent to the regenerant. Electrodes are placed along the length of the regenerant chambers. When an electric potential is applied across the electrodes, water from the regenerant chambers is electrolyzed, supplying regenerant hydronium ions (H 3 O + ) in the ASRS 300 and regenerant hydroxide ions (OH - ) in the CSRS 300 for the neutralization reaction. The membrane allows hydronium or hydroxide ions to pass into the eluent chamber resulting in the conversion of the electrolyte of the eluent to a weakly ionized form. Eluent counter ions (cations in anion exchange or anions in cation exchange) are simultaneously passed into the regenerant chamber to maintain charge balance. The eluent suppression process is illustrated for Anion Suppressor in Figure 2 and for Cation Suppressor in Figure 3. As shown in Figure 2, the water regenerant undergoes electrolysis to form hydrogen gas and hydroxide ions in the cathode chamber while oxygen gas and hydronium ions are formed in the anode chamber. In the Anion Suppressor, cation exchange membranes allow hydronium ions to move from the anode chamber into the eluent chamber to neutralize hydroxide. Sodium ions in the eluent, attracted by the electric potential applied, move across the membrane into the cathode chamber to maintain electro neutrality and combine with the hydroxide ions generated at the cathode. Thus effecting suppression of the eluent and conversion of the analyte to typically a more conductive acid form. ASRS 300 in AutoSuppression Mode ANODE + Waste/Vent ANALYTE IN Na + OH - ELUENT (NaOH) CATHODE Waste/Vent - H 2 O + O 2 Na + OH - + H 2 H 3 O + Na + OH - OH - 2H 3 O + + ½ O 2 (g) H H OH - 2 O 3H 2 O 2 H 2 O ANALYTE IN H 2 O H 2 O H 2 O TO DETECTOR Figure 2 AutoSuppression with the ASRS 300

7 SRS 300 Product Manual Page 6 of 50 As shown in Figure 3, the water regenerant undergoes electrolysis to form hydrogen gas and hydroxide ions in the cathode chamber while oxygen gas and hydronium ions are formed in the anode chamber. In the cation suppressor, anion exchange membranes allow hydroxide ions to move from the cathode chamber into the eluent chamber to neutralize hydronium ions. Anions in the eluent, such as methane sulfonate, attracted by the electric potential applied, move across the membrane into the anode chamber to maintain electro neutrality and combine with the hydronium ions generated at the anode. Thus effecting suppression of the eluent and conversion of the analyte to typically a more conductive base form. CSRS 300 in AutoSuppression Mode ANODE + Waste/Vent ANALYTE IN H + MSA - ELUENT (MSA) CATHODE Waste/Vent - MSA + O 2 H 2 O + H 2 H + + MSA - MSA - + H + OH - [H + + OH - ] 2H 3 O + + ½ O 2 (g) H H OH - 2 O 3H 2 O 2 H 2 O ANALYTE IN H 2 O H 2 O H 2 O TO DETECTOR Figure 3 AutoSuppression with the CSRS 300 The ASRS 2 mm suppressor is compatible with the MS and replaces the ASRS MS suppressor product. The suppressor has been designed to have minimal sulfate interference for MS applications. The 2 mm suppressor is recommended for MS applications due to the improved efficiency, and since less eluent enters the MS at the relatively lower operational flow rate.

8 SRS 300 Product Manual Page 7 of Overview of Suppression Modes Four basic modes of suppression can be performed with the Self-Regenerating Suppressor (SRS 300): AutoSuppression Recycle Mode AutoSuppression External Water Mode Chemical Suppression Mode MPIC Suppression Mode AutoSuppression Recycle Mode: The SRS 300 uses water as the regenerant for eluent suppression. There are two modes of electrolytic operation. The most simple and recommended mode of operation is the AutoSuppression Recycle Mode. In this mode of operation, eluent flows from the eluent outlet of the suppressor into the conductivity cell and is then recycled through the SRS 300 regenerant chambers. This eliminates the need for an external source of regenerant water but limits the regenerant flow rate to the eluent flow rate. The AutoSuppression Recycle Mode is the most common mode of operation and is recommended for aqueous eluents. AutoSuppression External Water Mode: This mode incorporates an external source of deionized water flowing through the regenerant chambers. The detector cell effluent is directed to waste. This requires the installation of pressurized bottle system or additional pump to provide an external source of water. With this configuration the regenerant flow rate is not limited to the eluent flow rate. The AutoSuppression External Water mode is primarily recommended with solvent containing eluents (up to 40%) Chemical Suppression Mode: The Chemical Suppression Mode is a non-electrolytic mode of operation and therefore requires no power supply. This mode of operation requires the installation of equipment (either the AutoRegen Accessory equipped with a AutoRegen Regenerant Cartridge, a pressurized bottle delivery system or additional pump, or a Displacement Chemical Regeneration (DCR) Kit). This system delivers sulfuric acid to the ASRS 300 suppressor or tetrabutylammonium hydroxide (TBAOH) to the CSRS 300 suppressor regenerant chambers. MPIC Suppression Mode: The MPIC Suppression Mode is a combination of the AutoSuppression External Water Mode augmented with a chemical regenerant such as sulfuric acid (ASRS 300) or boric acid (CSRS 300). When the SRS 300 is operating in this mode, it uses an applied current and a constant source of dilute regenerant solution from a pressurized bottle delivery system or additional pump. The following sections explain how each mode works and help to determine which mode to use for an application. Once the mode of operation is determined, more detailed plumbing configuration and operating instructions can be found in Section 3, Operation Mode of Operation Selection The SRS 300 mode of operation depends mainly on your eluent composition and your analysis sensitivity requirements. The compatibilities are shown in Table 1. For example, eluents containing organic solvents are not compatible with the AutoSuppression Recycle Mode. The AutoSuppression External Water Mode or Chemical Suppression Mode should be used instead. The MPIC Suppression Mode is specifically designed for applications where ion-pair reagents and solvents are present in the eluent. Table 1 Eluent Composition and Suppression Mode Compatibility Eluent Composition Suppression Recycle Suppression External Water Chemical Suppression MPIC Suppression Aqueous Eluents Yes Yes Yes N/A Eluents Containing No Yes (Up to 40%) Yes (Up to 100%) N/A Organic Solvents Eluents Containing Ion Pair Reagents with/without Solvents No No No Yes

9 SRS 300 Product Manual Page 8 of The AutoSuppression Recycle Mode The AutoSuppression Recycle Mode uses the neutralized conductivity cell effluent as the source of water for the regenerant chamber water. This is the preferred method of operation for the SRS 300. The advantage of this mode of operation is simplicity and ease of use. This mode reliably provides AutoSuppression for most suppressed conductivity applications using solvent-free eluents. As the eluent passes through the SRS 300, it is neutralized to its weakly ionized form. After passing through the conductivity cell, the effluent is redirected to the regenerant inlet on the SRS 300, thus supplying it with a source of water containing minute amounts of diluted analyte. The amount of water flowing through the regenerant chambers is therefore limited to the eluent flow rate. See Section 3 for complete operating instructions The AutoSuppression External Water Mode The AutoSuppression External Water Mode is used for any application requiring organic solvents in the eluent or sample. This mode uses a constant source of deionized water from a pressurized bottle or other source of deionized water that delivers 1 to 2 ml/min for 2-mm applications and 3-5 ml/min for 4-mm applications. The amount of water flowing through the regenerant chambers is therefore independent of the eluent flow rate. The AutoSuppression External Water Mode eliminates the potential for build-up of contaminating ions resulting from the oxidation of solvents. It also reliably provides AutoSuppression for high sensitivity analysis, maximizing signal-to-noise ratios for suppressed conductivity applications. Any analysis performed using the AutoSuppression Recycle Mode can also be performed using the AutoSuppression External Water Mode. See Section 3 for complete operating instructions The Chemical Suppression Mode Dionex recommends the use of a MicroMembrane Suppressor (MMS 300) for chemical suppression applications. The SRS 300 can also be used in the Chemical Suppression Mode. The chemical suppression mode should be used for applications using 40% (V/V), or greater solvent or where the lowest noise is required. In this mode no power or current is applied. The Anion Chemical Suppression Mode uses sulfuric acid (H 2 SO 4 ) as a chemical regenerant and the Cation Chemical Suppression Mode uses tetrabutylammonium hydroxide (TBAOH) as a chemical regenerant. Dionex recommends for typical anion applications a sulfuric acid regenerant concentration between 25 mn and 75 mn and for typical cation applications a TBAOH regenerant concentration of between 50 mn and 100 mn. It should be noted that there will be a small leakage of regenerant ions into the eluent channel and is dependent primarily on the concentration of the regenerant used. A lower regenerant concentration is preferred at a relatively higher flow rate since it produces a lower level of leakage hence a lower background, than a higher regenerant concentration at a lower flow rate. In the Chemical Suppression Mode, the SRS 300 is operated exactly like a MicroMembrane Suppressor (MMS 300). Regenerant is supplied to the regenerant chambers from a Dionex AutoRegen Accessory or a pressurized bottle delivery system or additional pump or a Displacement Chemical Regeneration (DCR) Kit. See Section 3 for complete operating instructions or refer to the MMS Manual Document No and the DCR Kit Manual Document No

10 SRS 300 Product Manual Page 9 of 50 Chemical Suppression with the ASRS 300 is a neutralization reaction and selective desalting process carried out across the cation exchange membranes. In this mode, no electric potential is applied across the electrodes. Hydronium ions in the chemical regenerant cross the membranes and combine with the basic eluent anions (in this case hydroxide) to form water. At the same time, eluent cations cross the membranes into the regenerant stream replacing the hydronium ions. ASRS 300 in Chemical Suppression Mode ANALYTE IN Na + OH - Waste/Vent ELUENT Waste/Vent Na + + HSO 4 - Na + + HSO 4 - Na + Na + H + H + + OH - H + H 2 O HSO 4 - HSO 4 - ANALYTE IN H 2 O H - + HSO 4 - H - + HSO 4 - TO DETECTOR Figure 4 Chemical Suppression with the ASRS 300 NOTE Do not plug the ASRS 300 to the SRS power supply

11 SRS 300 Product Manual Page 10 of 50 Chemical Suppression with the CSRS 300 is a neutralization reaction and selective desalting process carried out across the anion exchange membranes. In this mode no electric potential is applied across the electrodes. Hydroxide ions in the chemical regenerant cross the membranes and combine with the acidic eluent cations, in this case hydronium ion, to form water. At the same time, eluent anions cross the membranes into the regenerant stream replacing the hydroxide ions. CSRS 300 in Chemical Suppression Mode ANALYTE IN H + MSA - Waste/Vent ELUENT Waste/Vent TBA + + MSA - TBA + + MSA - MSA - MSA - OH - H + + OH - OH - H 2 O TBA + TBA + ANALYTE IN H 2 O TBA + + OH - TBA + + OH - TO DETECTOR Figure 5 Chemical Suppression with the CSRS 300 NOTE Do not plug the CSRS 300 to the SRS power supply

12 SRS 300 Product Manual Page 11 of The MPIC Suppression Mode Anion MPIC The ASRS 300 is used for eluent suppression of Mobile Phase Ion Chromatography (MPIC or ion-pairing) eluents by using the MPIC Suppression Mode. The MPIC Suppression Mode is a combination of the AutoSuppression External Water Mode augmented with a chemical regenerant such as sulfuric acid (H 2 SO 4 ). The MPIC Suppression Mode uses an applied current and a constant source of dilute sulfuric acid solution from a pressurized bottle delivery system. This mode must be used for MPIC applications requiring an ion pair reagent and organic solvents in the eluent. The MPIC Suppression Mode reliably provides suppression of typical eluents for MPIC applications using suppressed conductivity detection. The ion pair reagents, such as tetrabutylammonium hydroxide (TBAOH), are used in concentrations typically ranging from 1.0 to 5.0 mm. See Section 3 for complete operating instructions Cation MPIC The CSRS 300 is used for eluent suppression of MPIC eluents by using the AutoSuppression External Water Mode or the MPIC Suppression Mode depending on the specific MPIC application. The MPIC Suppression Mode uses an applied current and a constant source of dilute boric acid regenerant solution from a pressurized bottle delivery system. Dilute boric acid is added to the water regenerant to enhance detection and improve linearity of weak bases such as ammonia and amines. This mode is used for MPIC applications requiring an ion pair reagent and organic solvents in the eluent. The MPIC Suppression Mode reliably provides suppression of typical eluents for MPIC applications using suppressed conductivity detection. The ion pair reagents, such as octanesulfonic acid (OSA), are used in concentrations typically ranging from 1.0 to 5.0 mm. Organic solvent concentrations should not exceed 40%. See Section 3 for complete operating instructions.

13 SRS 300 Product Manual Page 12 of INSTALLATION 2.1. System Requirements The SRS 300 is designed to be run on any Dionex Ion Chromatography System (ICS) equipped with a Anion or Cation exchange column set and suppressed conductivity detection. The ICS-2500, ICS-2000, and ICS-1500 systems are fully capable of controlling the suppressor from either the front panel touch screen or from Chromeleon software. The ICS-1000 and ICS-3000 systems control the suppressor only through Chromeleon software. DX-500 systems with a CD20 or ED40 Detector; DX-120 systems; DX-300 systems having a Conductivity Detector Module (CDM-3) or a Pulsed Electrochemical Detector (PED-2); and the DX-100 (Model DX 1-03) contain SRS Control integrated into the detector. Older systems require a standalone controller such as the SCR-1, SC20, RFC-10, or RFC-30 Controller for installation of the SRS 300. See Table 2, Self-Regenerating Suppressor Requirements for Selected ICS Modules. The older SRC-1 controller has been discontinued. The replacement product is either the RFC-10 controller or the RFC-30 controller. The RFC-10 controller provides 1 ma graduated control of an electrolytic suppressor. The RFC-30 controller also provides 1 ma graduated control and, in addition, provides control of an Eluent Generator Cartridge (EGC) and a Continuously Regenerated Trap Column (CR-TC). It is highly recommended to set the current setting for the SRS 300 to the exact calculated current (within 1 ma). Older power supplies do not have the 1 ma graduated control. For older systems it is recommended to upgrade to a newer power supply such as the RFC-10 or RFC-30. Failure to set the current accurately could reduce performance. Table 2 Self-Regenerating Suppressor Requirements for Selected Ion Chromatographs Ion Chromatograph Series Module RFC-10 or RFC-30 Controller Requirement 2000i YES QIC YES 2000 SP YES 4000i YES 4500i YES 8000 YES 8100 N/A 8200 N/A DX-100 YES Model DX 1-03 RECOMMENDED DX-120 RECOMMENDED DX-300 N/A CDM-2, PED YES CDM-3, PED-2 RECOMMENDED DX-320 with IC20 or IC25 RECOMMENDED DX-320 with IC25A NO DX-500 RECOMMENDED DX-600 with CD25A or ED50A NO DX-600 with CD25 or ED50 RECOMMENDED DX-800 RECOMMENDED ICS-90 N/A ICS-1000 NO ICS-1500 NO ICS-2000 NO ICS-2500 NO ICS-3000 NO

14 SRS 300 Product Manual Page 13 of 50 The SRS 300 is installed in the column chamber of the chromatography module immediately after the analytical column and before the conductivity detector cell. All components required for installation of the SRS 300 are included with the system. Gas Separator Waste Tube (P/N ) Backpressure coil(s) 4-mm (P/N ) 2-mm (P/N ) Microbore Tubing (2-mm only) (P/N ) Mounting clip (P/N ) Options: MMS/SRS Installation Kit (P/N ) (Pressurized Water Delivery System used with AutoSuppression External Water Mode, Chemical Suppression Mode, or MPIC Suppression Mode) Peristallic Pump Kit (P/N: ). (Water delivery system used with AutoSuppression External Water Mode, Chemical Suppression Mode or MPIC Mode. CAUTION The SRS 300 must be operated with the Gas Separator Waste Tube (P/N ) NOTE The use of 1/4-28 or ferrule/bolt style liquid lines may be required for installation and use of SRS 300. See Dionex Liquid Line Fittings for complete details Self-Regenerating Suppressor Control The SRS control is provided by discreet (50,100,300 and 500mA) and non discreet (0 to 500 ma in 1mA increment) power supplies. Discreet SRS Control is integrated into the CDM-3 and PED-2 of the DX-300, the DX-100 (Model 1-03), DX-120, DX-320 (IC20 and IC25 models), DX-500 (CD20 and ED40 detectors), and DX-600 (CD25 and ED50 detectors). For applications that require intermediate current values the use of a non-discreet power supply, such as the SC20, RFC-10 or RFC-30 is highly recommended. Non-discreet SRS Control is integrated into modern instruments including the DX-320 (IC25A model), DX-600/ICS-2500 (CD25A and ED50A detectors) and ICS series (excluding ICS-90 and ICS-900). CAUTION Always turn the pump and the SRS Control on and off at the same time. Eluent flow through the SRS 300 is required for proper operation. However, without current, the membranes and screens in the SRS 300 will become expended by the flowing eluent resulting in small analyte peak areas. If this should occur, perform the procedure in Section Reagent-Free Controller (RFC) The Reagent-Free Controller (RFC) is an external power supply available in two versions. The RFC-10 controls the SRS 300 Self-Regenerating Suppressor or an AES Atlas Electrolytic Suppressor. Current is delivered at 1 ma resolution. The RFC-30 controls an SRS 300 Self-Regenerating Suppressor or AES, as well as an EluGen Eluent Generator Cartridge (EGC) and a CR-TC Continuously Regenerated Trap Column. Current is delivered at 1 ma resolution. The RFC controls these devices by supplying current to the suppressor and for the RFC-30, current to the eluent generator and voltage (to the CR-TC). Please see the RFC Operator s Manual for suppressor operating and installation instructions with the following Dionex products: DX-320/320J DX-500, DX-600, or ICS-2500 DX-120

15 SRS 300 Product Manual Page 14 of Back Pressure Coils for the SRS 300 All detector cells require enough back pressure to prevent eluent in the cell from out-gassing due to abrupt volume changes between the small inner diameter of the connecting tube and the relatively larger volume of the cell. Out-gassing creates bubbles in the cell and disrupts detector responsiveness. Back pressure coils help to prevent gases, generated during AutoSuppression, from out-gassing and formation of bubbles in the detector cell. For example, carbonate eluent is suppressed to carbonic acid which is CO 2 gas in equilibrium with DI water and CO 2 gas can come out of solution if adequate pressure is not applied. The above out-gassing can trap bubbles in the cell causing high noise. Therefore Dionex recommends addition of psi of backpressure. Back pressure coil components are shipped with your system. For 4 -mm systems, locate assembly P/N For 2 -mm systems, the backpressure coils are also available in the microbore tubing kit, P/N For 2- mm systems, locate assembly P/N Alternatively, lengths and diameters of tubing necessary for proper back pressure are given in Table 3, Coils for SRS 300 Back Pressure Requirements. Adjust the tubing length to achieve a backpressure of approximately 40 psi. CAUTION If back pressure coils become damaged or plugged, they may cause irreversible damage to the suppressor Assembly A. Slip PEEK liquid line bolts and ferrules onto the ends of the tubing. Refer to Table 3, Coils for SRS 300 Back Pressure Requirements, and determine the correct number of coils required for your application based on the eluent flow rate. B. After assembly of the coils, see Figure 7, The AutoSuppression Recycle Mode Plumbing Diagram, for the proper placement of the completed coils and couplers between the SRS 300 and the Gas Separator Waste Tube. Table 3 Coils for SRS 300 Back Pressure Requirements SRS 300 Type P/N Flow Rate I.D. of Tubing Length of Each Coil Number of Coils 4-mm ml/min 0.010" (Black) 2.5 ft. 2 4-mm ml/min 0.010" (Black) 2.5 ft. 1 2-mm ml/min 0.005" (Red) 1.0 ft. 2 2-mm ml/min 0.005" (Red) 1.0 ft. 1 CAUTION The correct amount of back pressure for optimum operation is 40 psi. Back pressure over 150 psi after the SRS 300 can cause irreversible damage.

16 SRS 300 Product Manual Page 15 of Gas Separator Waste Tube for the SRS 300 The Gas Separator Waste Tube (P/N ) is an integral part of the SRS 300 system. It separates any hydrogen gas generated in the ASRS 300 during the electrolytic generation of hydronium ions (H3O+) or hydroxide ions (OH-) for the CSRS 300. The Gas Separator Waste Tube is used to avoid concentrating the gas in the waste container. The Gas Separator Waste Tube is shipped in one of the ShipKits of your system. CAUTION Do not cap the waste reservoir. SAFETY Minimal hydrogen gas generated by the SRS 300 is not dangerous unless the gas is trapped in a closed container and allowed to concentrate. The Gas Separator Waste Tube must be open to the atmosphere, and not in a confined space, to operate properly Assembly Assemble and install the Gas Separator Waste Tube and waste line following the steps below. See Figure 5, The AutoSuppression Recycle Mode Plumbing Diagram, or Figure 7, Configuration of the Pressurized Water Reservoir and the Gas Separator Waste Tube with the Self-Regenerating Suppressor. A. Use one or two couplers (P/N ) to connect two or three lengths of 1/2" i.d. black polyethylene tubing (P/N ) depending on the waste container depth. Extend the top of the Waste Separator Tube above the top of the Waste container. Place the Gas Separator Waste Tube with the 1/8" o.d. tubing attached into the waste container. Ensure the bottom of the Gas Separator Waste Tube is resting on the floor of the waste container, the top of the device (where the white 1/8" o.d. tubing meets the black 1/2" o.d. tubing) is above the top of the container, and that both the Gas Separator Waste Tube and the waste container are open to the atmosphere Self-Regenerating Suppressor Current Selection Lower current is better for the performance of both the SRS 300 and Atlas suppressors. Excess current through the suppressor devices causes excess heat generation and over time will cause the ion exchange materials to degrade, thus shortening suppressor lifetime. Excess current can also cause poor recoveries of certain analytes, particularly magnesium, manganese and phosphate. The optimum current setting produces just enough hydronium or hydroxide ions to displace the eluent counter ions and neutralize the eluent and is the recommended setting. No more than 10% above the optimum current setting is recommended.

17 SRS 300 Product Manual Page 16 of Calculating the Optimum Current Setting The optimum current setting depends on the eluent concentration and flow rate. A concentrated eluent at a high flow rate requires a higher current setting than a diluted eluent at a low flow rate. These calculations are specific for the type of suppressor and vary for ASRS 300 and CSRS 300. Current (ma) = [flow rate (ml/min)] x [eluent concentration (mn)] x [a suppressor specific factor] The factors are listed in the table below. The unit for eluent concentration is mn (not mm). Table 4 Optimum Suppressor Settings Suppressor Type Suppressor Specific Factor ASRS CSRS Atlas (Anion and Cation) 3.34 NOTE Always round the calculated optimum current up to the nearest whole integer.

18 SRS 300 Product Manual Page 17 of 50 An RFC-10 or RFC-30 Controller, CD25A, ED50A, IC25A, ICS-1000, ICS-1500, ICS-2000, or ICS-3000 detector can be used to set the current at the calculated value with a minimum current resolution of 1 ma. NOTE The lower flow rates require a lower current. A 2 mm SRS 300 should NEVER be operated at a current above 100 ma. A. Maximum Suppression Capacity The Maximum Suppression Capacity (MSC) depends on the eluent concentration and flow rate. The MSC can be calculated using the following equation. MSC (mn * ml/min) = flow rate (ml/min) * sum of eluent concentration (mn) Table 5 Maximum Suppression Capacity for SRS 300 Suppressor Flow Rate (ml/min) Maximum Suppression Capacity ASRS mm µ equivalents ASRS mm < 50 µ equivalents ASRS mm < 30 µ equivalents CSRS mm < 100 µ equivalents CSRS mm < 35 µ equivalents CSRS mm µ equivalents B. Sum of Eluent Concentration Calculation The sum of the eluent concentration can be calculated from the equations below. ASRS 300 (4-mm) Sum of eluent concentration (mn) = {2* Carbonate (mm) + Bicarbonate (mm) + hydroxide (mm) + 2 * Tetraborate (mm) + custom eluent cation (mn)} where Tetraborate is <= 50 mm ASRS 300 (2-mm) Sum of eluent concentration (mn) = {2 * Carbonate (mm) + Bicarbonate (mm) + hydroxide (mm) + 2 * Tetraborate (mm) + custom eluent cation (mn)} where Tetraborate is <= 75 mm Custom eluent cation (mn) can be calculated from the normality of the eluent concentration. NOTE Normality is Equivalents/L of solution. For example, 20.0 mm sodium acetate (CH3COONa) has 20.0 mn sodium as the cation and 20.0 mm sodium sulfate (Na2SO4) has 40.0 mn sodium as the cation. When using the CSRS 300 (4-mm) and CSRS 300 (2-mm), the sum of the eluent concentration can be calculated using the equations below. CSRS 300 Sum of eluent concentration (mn) ={2 * Sulfuric Acid (mm) + MSA (mm) + custom eluent anion (mn)} Custom eluent anion (mn) can be calculated from the normality of the eluent concentration. NOTE Normality is Equivalents/L of solution. For example, 20.0 mm sodium acetate (CH3COONa) has 20.0 mn acetate as the anion and 20.0 mm sodium sulfate (Na2SO4) has 40.0 mn sulfate as the anion.

19 SRS 300 Product Manual Page 18 of OPERATION This section provides instructions for the start-up and operation of the SRS 300 including the selection process and suppression modes of operation Chemical Purity Requirements Precise and accurate results require eluents free of ionic impurities. Chemicals and deionized water used to prepare eluents must be pure as described below. Low trace impurities and low particulate levels in eluents and regenerants also help protect the SRS 300 and system components from contamination. SRS 300 performance is not guaranteed when the quality of the chemicals and water used to prepare eluents has been compromised Inorganic Chemicals Reagent Grade inorganic chemicals should always be used to prepare ionic eluents. Preferably, a lot analysis on each label will certify each chemical as meeting or surpassing the latest American Chemical Society standard for purity, a universally accepted standard for reagents Solvents Since solvents used with the SRS 300 are added to ionic eluents to modify the ion exchange process or improve sample solubility, the solvents used must be free of ionic impurities. However, since most solvent manufacturers do not test for ionic impurities, the highest grade of solvents available should be used. Currently, several manufacturers are making ultra-high purity solvents that are compatible for HPLC and spectrophotometric applications. These ultra-high purity solvents will usually ensure that your chromatography is not affected by ionic impurities in the solvent. Dionex has obtained consistent results using High Purity Solvents manufactured by Burdick and Jackson and Optima Solvents by Fisher Scientific Deionized Water The deionized water used to prepare eluents should be degassed Type I Reagent Grade Water with a specific resistance of 18.2 megohm-cm. The water used for the AutoSuppression External Water Mode should have a specific resistance of 18.2 megohm-cm or greater. The deionized water should be free of ionized impurities, organics, microorganisms and particulate matter larger than 0.2 µm. It is good practice to filter eluents through a 0.2 µm filter whenever possible. Bottled HPLC-Grade Water should not be used since most bottled water contains an unacceptable level of ionic impurities. Finally, thoroughly degas all deionized water prior to preparing any eluents or regenerants Start-up The SRS 300 is installed in the column chamber of the chromatography module right after the analytical column and before the conductivity detector cell. On the ICS-3000, the suppressor mounts on the conductivity detector module in the DC. On the ICS-2000, the ICS-1500, and the ICS-1000, the suppressor mounts on the component panel behind the ICS front door. Refer to the ICS Operator's Manual for further details. On the DX-500, DX-120, and DX-100 instruments, the SRS 300 mounts on tabs on the component panel. Orient the SRS 300 with the ELUENT IN port and the cable at the top; align the slots on the back of the SRS 300 with the tabs on the panel. Press in, and then down, to lock the SRS 300 in place. Lift up and pull out to remove the SRS 300. Ensure the SRS 300 is plumbed properly according to the selected mode of operation. Refer to Section 2, Installation, for complete installation instructions. WARNING Keep the regenerant chambers full with the appropriate regenerant solution or water. The membranes and screens in the SRS 300 must be completely hydrated to maintain liquid seals and chromatographic performance. CAUTION The correct amount of back pressure for optimum operation is 40 psi. Connect the back pressure coil(s) appropriate for your column i.d. and flow rate. Back pressures over 150 psi after the SRS 300 can cause irreversible damage.

20 P / N SRS 300 Product Manual Page 19 of 50 CAUTION Do not cap the waste reservoir. SAFETY Hydrogen gas generated by the SRS 300 is not dangerous unless the gas is trapped in a closed container and allowed to concentrate. The Gas Separator Waste Tube must be open to the atmosphere, and not in a confined space, to operate properly Hydration 1. Hydrating the suppressor ensures that the ion exchange membranes are in a swollen form for proper operation. A 20 minute static step is recommended during first time installation to ensure complete hydration. 2. Using a disposable plastic syringe and the Luer adapter (P/N ), push approximately 3 ml (SRS 4-mm) or 0.75 ml (SRS 2-mm) of degassed DI water through the ELUENT OUT port. Using a disposable syringe and the 1/4-28 Luer adapter (P/N ), push 5 ml (SRS 4-mm) or 2 ml (SRS 2-mm) of degassed DI water through the REGEN IN port, according to Figure 6. NOTE Step 1 can be accomplished by installing the suppressor in the system in the recycle mode, bypassing the guard and analytical columns, and pumping 5 ml (SRS 4-mm) or 2 ml (SRS 2-mm) of deionized water through the suppressor. P/N Description cc plastic syringe /4-28 Luer adapter Luer adapter Union Bolt Double Cone Ferrule 1C C 1.0 c c s yringe Bolt and Ferrule L u e r a d apter Union ELUENT IN REGENOUT DIONEX ANION SELF-REGENERATING SUPPRESSORASRSULTRA 4-mm ELUENTOUT REGEN IN D I H 2 O D IH 2 O Figure 6 Hydrating the Suppressor 3. Allow the suppressor to sit for approximately 20 minutes to fully hydrate the suppressor screens and membranes. WARNING Do not install a luer adapter directly into a SRS 300 port. Connect a luer adapter to a union and use two bolt and ferrules with a few centimeters of tubing to connect to the SRS ports.

21 SRS 300 Product Manual Page 20 of Back Pressure Coil Pressure Test 1. Disconnect the eluent line from the injection valve to the column at the column inlet. Injection Valve 2. Connect the eluent line from the injection valve directly to the detector cell inlet with the recommended number of back pressure coils attached for your application (see the table below). Turn the pump on at your application flow rate. After 2 to 3 minutes of equilibration record pressure P Disconnect the back pressure coils and with the pump on measure the system pressure P 2. Coil #1 Cell Coil #2 4-mm Chromatography 2-mm Chromatography Waste 1.0 ml/min. = 2 black backpressure coils 0.25 ml/min. = 2 red backpressure coils (P/N ) (P/N ) 2.0 ml/min. = 1 black backpressure coil 0.50 ml/min. = 1 red backpressure coil (P/N ) (P/N ) 4. The correct operating pressure range for the backpressure coil being tested is Injection Valve SRS 300 P 1 - P 2 = psi If the pressure is greater than 40 psi, then trim the back pressure coil and repeat step 2 and 3 to achieve psi in step 4. Cell If it is less than 30 psi, then add more tubing to achieve psi Quick Back Pressure Check Waste This section describes how to measure the backpressure to the suppressor. Install the system for the application of choice. 1 Measure the system pressure P1 with the suppressor powered 2. Unplug the line from the Eluent Out port on the suppressor and measure system pressure P 2 CAUTION Do not leave the port open for more than 2 minutes. 3. P 1 -P 2 < 100 psi. 4. Adjust the backpressure coils if needed to achieve the < 100 psi value. Refer to to measure the back pressure contribution from the back pressure coil.

22 SRS 300 Product Manual Page 21 of Plumbing for the AutoSuppression Recycle Mode Operation Figure 7 The AutoSuppression Recycle Mode Plumbing Diagram The AutoSuppression Recycle Mode is the easiest method of operation. As the eluent passes through the suppressor, it is neutralized to produce its weakly ionized form. After passing through the conductivity cell, this effluent can be redirected to the regenerant inlet on the suppressor, thus supplying it with a source of water containing a small amount of diluted analyte (see Figure 7). The main advantage of this mode is its simplicity and ease of use. It is not necessary to have an external supply of water available for the suppressor. CAUTION Only use the AutoSuppression Recycle Mode for eluents without organic solvents or metallic contaminants such as iron in ground water Eluent Flow Path Connections in the AutoSuppression Recycle Mode Depending on the specific components (analytical column, conductivity cell, back pressure coils) in the system, 1/4-28 or ferrule/bolt liquid lines may be required. All necessary tubing and fittings are supplied in the detector or RFC-10 or RFC- 30 Ship Kits. To purchase or assemble 1/4-28 or ferrule/bolt liquid lines, refer to, Dionex Liquid Line Fittings. Always use 0.005" i.d. PEEK tubing with ferrule/bolt fittings on 2 mm systems. Use 0.010" i.d. PEEK tubing with ferrule/bolt fittings on 4 mm systems when possible. Avoid adding dead volume to the system by keeping all eluent lines as short as possible. A. Install the SRS 300 inside the ICS Module. B. Connect the outlet of the analytical column to the ELUENT IN of the SRS 300 (Figure 7). C. Connect the ELUENT OUT port of the SRS 300 to the inlet of the conductivity cell (Figure 7).

23 SRS 300 Product Manual Page 22 of Regenerant Flow Path Connections in the AutoSuppression Recycle Mode Connect the back pressure coil(s) between the CELL OUTLET port and the REGEN IN port (see Figure 7 and Section 2). The back pressure coils are provided in the Gas Separator Waste Tube Components Assembly (P/N ) for 4-mm systems. The backpressure coils for 2-mm systems are provided in the microbore tubing kit (P/N ). CAUTION The SRS 300 must be operated with the Gas Separator Waste Tube (P/N ) Installation in Thermal Chamber A. Installation instructions for single temperature zone ICS-3000 DC. 1. For all applications up to 35 C the suppressor is installed inside the heated DC enclosure. Install the suppressor using the suppressor holder on the CD. 2. For applications above 35 C up to 40 C, it is recommended the SRS 300 is installed outside the DC. B. Installation instructions for dual temperature zone ICS-3000 DC. 1. Install the suppressor using the suppressor holder on the CD in the upper compartment. Ensure the upper compartment temperature is set to a value no greater than 35 C and temperature control is turned on. It is recommended that the upper compartment is kept cooler than the lower compartment. The lower compartment (column oven) can be set to temperatures up to 70 C. C. Installation instructions for ICS 1000/1500/2000, AS50 thermal chamber TC and CC: 1. Install the suppressor using the suppressor holder. The suppressor is installed outside the heated column enclosure. It can support all high temperature applications up to 60 C. D. Installation instructions for LC30 and LC25 ovens: 1. For all ANION applications up to 35 C, install the suppressor in the oven using the SRS holder. 2. For operation above 35 C and up to 60 C, it is recommended that the ASRS 300 suppressor be installed outside the oven. This would ensure optimal performance of the suppressor in terms of noise and background. 3. For all CATION applications up to 40 C, install the suppressor in the oven using the SRS holder. 4. For operation above 40 C and up to 60 C, it is recommended that the CSRS 300 suppressor be installed outside the oven. This would ensure optimal performance of the suppressor in terms of background and noise. NOTE Operating the suppressor by installing the suppressor inside a column/thermal compartment or oven over 35 C will physically damage the suppressor. Set the required current based on your specific application requirements for column flow rate and temperature in addition to eluent concentration. If using Chromeleon software, the Wizards can greatly assist you in determining the correct requirements. Refer to Section 2 for suppressor current calculations and Appendix A for examples Installation in ICS 3000 In the single-zone (shared) configuration of the Detector Compartment (DC) module of the ICS 3000 system, the upper and lower compartments are at the same temperature. The suppressor should be installed in the upper compartment. In the dual-zone configuration of the DC module the upper and lower compartments have independent thermal control. The suppressor should be installed in the upper compartment. The allowed temperature setting for the upper compartment is 35 C

24 SRS 300 Product Manual Page 23 of Plumbing for the AutoSuppression External Water Mode Operation Figure 8 The AutoSuppression External Water Mode Plumbing Diagram Any analysis that can be performed using the AutoSuppression Recycle Mode can be done using the AutoSuppression External Water Mode. A constant source of deionized water having a specific resistance of 18.2 megohm, or greater, is supplied to the regenerant chambers to generate hydronium or hydroxide ions for neutralization. CAUTION AutoSuppression External Water Mode is used when organic solvents are present in the eluent. When the SRS 300 is operating in the AutoSuppression External Water Mode, the background noise may be lower than in the AutoSuppression Recycle Mode because the external water flow rate is not limited to the eluent flow rate. The independent source of external water allows for higher water flow rates and better sweep out of bubbles from the Regen chamber resulting in lower background noise Eluent Flow Path Connections for the AutoSuppression External Water Mode Depending on the specific components in the system (such as analytical column, conductivity cell, back pressure coils), 1/4-28 or ferrule/bolt liquid lines may be required. All necessary tubing and fittings are supplied in the detector or RFC-10 or RFC-30 Ship Kits. To purchase or assemble 1/4-28 or ferrule/bolt liquid lines, refer to, Dionex Liquid Line Fittings. Always use 0.005" i.d. PEEK tubing with ferrule/bolt fittings on 2 mm systems. When possible, use 0.010" i.d. PEEK tubing with ferrule/bolt fittings on 4 mm systems. Avoid adding dead volume to the system by keeping all eluent lines as short as possible. A. Install the SRS 300 in the first slot inside the Chromatography Module. B. Connect the outlet of the analytical column to the ELUENT IN of the SRS 300 (Figure 8).

25 SRS 300 Product Manual Page 24 of 50 C. Connect the ELUENT OUT port of the SRS 300 to the inlet of the conductivity cell (see Figure 8). D. Install a waste line from the conductivity cell that generates 40 psi back pressure at the flow rate required by the application. Use the appropriate i.d. tubing depending on your application requirements. Refer to Section 2 and see Figure 7 for the correct back pressure tubing requirements. E. Install and adjust the flow rate of water from the pressurized water delivery system to the regenerant chambers of the SRS 300 (see Section 3). CAUTION The correct amount of back pressure for optimum operation is 40 psi. Back pressures over 150 psi can cause irreversible damage Regenerant Flow Path Connections in the AutoSuppression External Water Mode The SRS 300 Pressurized Bottle Installation Kit (P/N ) contains all of the components needed to install and operate the SRS 300 with a pressurized water reservoir. The kit contains the SRS Installation Parts Kit (P/N ), a 25 psi regulator (P/N ) and a 4 liter water reservoir (P/N ). A. Make the following air line connections: 1. Locate the pieces of tinted 1/8" o.d. plastic tubing (P/N ) supplied in the Installation Parts Kit. 2. Push the end of one piece of 1/8" o.d. tubing over the barbed fitting of the regulator. Connect the other end of the tubing to the source of air pressure. 3. Push one end of the second piece of 1/8" o.d. tubing over the other barbed fitting of the regulator. Push the other end of this tubing over the barbed fitting (P/N ) in the pressure inlet of the plastic reservoir (see Figure 13). B. Make the following water line connection. 1. Use a coupler (P/N ) to connect one end of the 30" tubing assembly (P/N ) that comes in the Installation Kit to the water reservoir. Connect the other end of this tubing to the REGEN IN port of the Self- Regenerating Suppressor. 2. Using a coupler (P/N ) and a 1/8" o.d. piece of tubing (P/N ) from the Installation Kit, connect one end of this line to the REGEN OUT port of the SRS 300 and then connect the other end of the line to the Gas Separator Waste Tube. C. Fill the water source reservoir. Make sure that the O-ring is inside the cap of the reservoir before screwing the cap onto the reservoir. Screw the cap onto the reservoir tightly and place the reservoir near the Chromatography Module. D. With no current applied, adjust the external water flow rate to approximately 3 5 ml/min for the SRS 300 (4-mm) and 1 3 ml/min for the SRS 300 (2-mm) by using a graduated cylinder and measuring the flow from the REGEN OUT waste line. The pressure applied to the reservoir can vary from 0 25 psi (the lower and upper pressure limits of the water reservoir) but the typical operating pressure is between psi. Please note that this value is highly system dependent. After turning on the current, the external water flow rate will be less because the electrolysis of water will generate a small amount of hydrogen and oxygen gases that will be seen as bubbles from the REGEN OUT waste line. In summary, the final external water flow rate is dependent on two factors: the pressure applied to the water reservoir and the current setting. It is best to measure it with the current off since the formation of bubbles will decrease the accuracy of the overall measurement. SAFETY A safety relief valve on the reservoir regulator prevents pressure greater than 25 psi from being applied to the water reservoir.

Dionex ERS 500 Suppressor

Dionex ERS 500 Suppressor Thermo Scientific Dionex ERS 500 Suppressor Product Manual P/N: April 2013 Part of Thermo Fisher Scientific Product Manual for Dionex Anion Electrolytically Regenerated Suppressor 500 (Dionex AERS 500

More information

Dionex IonPac AS19-4µm

Dionex IonPac AS19-4µm Total Thermo Scientific Dionex IonPac AS19-4µm Column Product Manual P/N: March 2015 Part of Thermo Fisher Scientific Product Manual for Dionex IonPac AS19-4µm Column Dionex IonPac AG19-4µm Capillary Guard

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

LC, RSLC, Bio RS and Dual Gradient Systems

LC, RSLC, Bio RS and Dual Gradient Systems Thermo Scientific Dionex UltiMate 3000 LC, RSLC, Bio RS and Dual Gradient Systems P/N 4823.0205 Revision B December 2014 Automated Method Scouting Considerations All information in this manual is subject

More information

UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions

UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions January 2010 Rev. 02 Table of Contents 1. Introduction... 1 1.1 How to Use this Manual... 1 1.2 Definition of LCi... 2 1.3

More information

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS 2000 Dionex Corporation Document No. 031277 Revision 03 April 2000 2000 Dionex Corporation All rights reserved worldwide. Printed in the United States of

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

Acclaim RSLC. (Rapid Separation Liquid Chromatography) Acclaim RSLC (Rapid Separation Liquid Chromatography) Product Manual for Acclaim RSLC Columns Page 1 of 9 Product Manual for Acclaim RSLC Columns (Rapid Separation Liquid Chromatography) Analytical Columns

More information

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results Nitrogen Generator Whisper-N2 Series Features Membrane Technology Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

More information

AKTA pure 25 New Owner s Intro

AKTA pure 25 New Owner s Intro AKTA pure 25 New Owner s Intro The exercise below will give a quick demonstration of how easy and intuitive the AKTA pure 25 will be for you in demonstrating downstream processing to your students. Steps

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Ultrafiltration for High Purity Distribution K-A-HPTUF Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2

More information

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE. Gases&Technology FEATURE Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. B Y M A T T H E W M O N A G L E Abstract Bulk gases are often delivered to

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008 UNITY 2 TM Air Server Series 2 Operators Manual Version 1.0 February 2008 1. Introduction to the Air Server Accessory for UNITY 2...2 1.1. Summary of Operation...2 2. Developing a UNITY 2-Air Server method

More information

no peaks missing peaks too small peaks increasing retention decreasing retention

no peaks missing peaks too small peaks increasing retention decreasing retention GC Troubleshooting We can help you. 1. Observation: no peaks no peaks missing peaks too small peaks increasing retention decreasing retention declining baseline rising baseline bleeding plateaus interfering

More information

Super-Clean Gas Filters from Restek

Super-Clean Gas Filters from Restek Super-Clean Gas Filters from Restek Chromatography Products www.restek.com 800-356-688 84-353-300 regulator instrument-grade tubing on/off valve GC carrier gas moisture trap hydrocarbon trap high-capacity

More information

DEBUBBLERS & DEGASSERS ACTIVE DEBUBBLERS APPLICATION NOTE WHY DEGAS YOUR MOBILE PHASE? PAGE 177 STAND ALONE DEGASSERS PAGE 175 PAGE 178

DEBUBBLERS & DEGASSERS ACTIVE DEBUBBLERS APPLICATION NOTE WHY DEGAS YOUR MOBILE PHASE? PAGE 177 STAND ALONE DEGASSERS PAGE 175 PAGE 178 174 DEBUBBLERS & DEGASSERS ACTIVE DEBUBBLERS PAGE 175 APPLICATION NOTE WHY DEGAS YOUR MOBILE PHASE? PAGE 177 STAND ALONE DEGASSERS PAGE 178 SEE STARRED PRODUCTS FOR TOP SELLERS! Series DEBUBBLERS & DEGASSERS

More information

INSTRUMENT INSTRUMENT YL INSTRUMENT

INSTRUMENT INSTRUMENT YL INSTRUMENT INSTRUMENT INSTRUMENT INSTRUMENT Nitrogen Generator Whisper-N2 Series Features Membrane Technology Compressed air is forced through a hollow fiber membrane, with selective permeation of the different components

More information

Rapid and Reliable Detection of Dissolved Gases in Water

Rapid and Reliable Detection of Dissolved Gases in Water Rapid and Reliable Detection of Dissolved Gases in Water Andrea Caruso and Massimo Santoro Thermo Fisher Scientific, Milan, Italy Application Note 005 Key Words Chromeleon CDS, Environmental, Fracking,

More information

SOP: Buck Scientific BLC-20P HPLC Operation

SOP: Buck Scientific BLC-20P HPLC Operation Page 1 of 11 Approvals Preparer: John Buford Reviewer: Tim Kull Reviewer: Dr. Margaret Bryans Date: 16OCT13 Date: 30OCT13 Date: 31OCT13 1. Purpose 1.1. Basic operation of the Buck Scientific BLC-20P isocratic

More information

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve USER'S GUIDE Nanoflow Probe 3-4mm Red Stripe ptfe Sleeve To Injector ZU1XC Fused Silica 20µm 90µm TTF115 ptfe Sleeve Fused Silica 25µm 375µm Micromass UK Limited Floats Road Wythenshawe M23 9LZ Tel: +44

More information

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems Inorganic Analysis Chromatography Molecular Spectroscopy Thermal/Elemental Analysis Informatics Gas Chromatography MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass

More information

The instrument should have a mass range from 2 to 2000 m/z or better Interface

The instrument should have a mass range from 2 to 2000 m/z or better Interface Revised Specifications for Liquid Chromatography Mass Spectrometry (LC-MS/MS ) Triple Quadrupole Specification for Ultra-Fast Liquid Chromatography system Solvent Delivery 1) A quaternary Pump system for

More information

GCMSD-Headspace Analysis SOP

GCMSD-Headspace Analysis SOP Before you start GCMSD-Headspace Analysis SOP Method and Sequences names are restricted to 50 characters (MSD program will crash otherwise) The GC oven and Injection Ports need to be cooled to 50 oc to

More information

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel TANK MANAGER FOR TWO TANKS OPERATING MANUAL 10/31/11 C-More T6C L color touch panel 1 TABLE OF CONTENTS GENERAL...3 INSTALLATION...4 STONE TEST PROCEDURE...7 OPERATIONAL SUMMARY...7 AUTO CARBONATION...10

More information

InFlow Modular perfusion bioreactor

InFlow Modular perfusion bioreactor InFlow is an incubator compatible, modular bioreactor for the controlled, bidirectional and interstitial perfusion of up to 9 cell seeded scaffolds with culture medium. InFlow is ideal for general purpose

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs. Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography

More information

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.

More information

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule One Piece or Two? A one-piece fitting is more convenient and less cumbersome, since the ferrule cannot stick in a receiving port and the fitting is more easily found if dropped. With two-piece Fingertight,

More information

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist Thank you for purchasing an Agilent system. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is

More information

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Degassing ERC KK Saitama, Japan

Degassing ERC KK Saitama, Japan Degassing Degassing Solutions IDEX Health & Science degassers improve fluidic instrument precision and reliability by removing dissolved gases from fluids before they outgas and form problem-causing bubbles

More information

Gradients in ion chromatography. Optimal separation with shorter analysis time

Gradients in ion chromatography. Optimal separation with shorter analysis time Gradients in ion chromatography Optimal separation with shorter analysis time Gradients yield precise results faster 02 The goal of ion chromatography in a nutshell reads: optimum separation within an

More information

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany Manual Degasser DDG-75 April 2007 1 Manual Online Degasser DDG-75 DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE-68766 Hockenheim Germany Tel. +49-6205-9450-0 Fax. +49-6205-9450-33 email info@duratec.com

More information

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems Corporation Issued: 5/09 P/N: 600104 Rev. 2 Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems The Gas Addition Accessory permits the

More information

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310 www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Varian 310 310 LC/MS Manual System INCLUDES: 310-MS LC/MS triple quadrople

More information

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Agilent 1220 Infinity II LC Mobile Upgrade Kit Agilent 1220 Infinity II LC Mobile Upgrade Kit Note 1220 Infinity II LC Mobile Upgrade Kit This note describes the procedures to install an Mobile Upgrade kit to an existing Agilent 1220 Infinity II LC.

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions

More information

Best Practices for Installation of Gaseous Sample Pumps

Best Practices for Installation of Gaseous Sample Pumps Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure

More information

Clean Regulator/Fluororesin Type

Clean Regulator/Fluororesin Type Clean egulator/fluororesin Type Series Washing/ssembly Procedure Washing parts: ody, Valve diaphragm and Diaphragm Parts Degreasing washing DI water washing lcohol washing ssembly Inspection Wetted part

More information

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual BioAerosol Nebulizing Generator Operation and Maintenance User Manual INTRODUCTION The BANG or BioAerosol Nebulizing Generator is a unique nebulizer for the generation of aqueous aerosols at a low air

More information

Zebron Gas Management

Zebron Gas Management Zebron www.phenomenex.com/gasmanagement What are the key benefits of Zebron filters and traps? The high adsorption capacity of the Zebron Filters removes contaminants from mobile phase gases, reducing

More information

This test shall be carried out on all vehicles equipped with open type traction batteries.

This test shall be carried out on all vehicles equipped with open type traction batteries. 5.4. Determination of hydrogen emissions page 1 RESS-6-15 5.4.1. This test shall be carried out on all vehicles equipped with open type traction batteries. 5.4.2. The test shall be conducted following

More information

Setting a New Standard in Flash Chromatography Performance

Setting a New Standard in Flash Chromatography Performance Setting a New Standard in Flash Chromatography Performance What s New Faster Flow rates, up to 300 ml/min Higher pressures, up to 300 psi (20 bar) Bigger touchscreen, 12 or 15 inches Wider Dynamic Range

More information

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses VHP Tees & Crosses for Capillary Tubing VHP Tees & Crosses for 1/16 OD Tubing IDEX Health & Science offers Very High Pressure, designed to bring

More information

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD) Procedure No: SOP-026 Revision No: 1.0 January 24, 2011 Page No.: 1 of 10 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to meet

More information

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background 3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G6600-60058 Background Accumulation of contaminants, such as column bleed, impurities in detector gases and even carbon from

More information

Generating Calibration Gas Standards

Generating Calibration Gas Standards Technical Note 1001 Metronics Inc. Generating Calibration Gas Standards with Dynacal Permeation Devices Permeation devices provide an excellent method of producing known gas concentrations in the PPM and

More information

Fiber Optic SMA Z-Flow Cell Manual Version 2.1

Fiber Optic SMA Z-Flow Cell Manual Version 2.1 Fiber Optic SMA Z-Flow Cell Manual Version 2.1 The line of fiber optic SMA Z-Cells is the top choice for many absorbance measurements. SMA-Z-Cell path lengths are available between 2.5mm - 100mm and can

More information

Carrier Gases in Capillary GC

Carrier Gases in Capillary GC Carrier Gases in Capillary GC LC Columns and Consumables Mark Sinnott Application Engineer January 15, 2009 CARRIER GAS Mobile Phase Carries the solutes down the column Selection and velocity influences

More information

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction Application Note Rapid performance verification of AZURA systems with refractive index detector Method Keywords ID HPLC Quality control, system verification, refractive index, AZURA Analytical HPLC Plus

More information

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen. APPLICATIONS: Autoclaves Modified Packaging Atmospheres Coffee Packaging Oxidation Control Coil Tubing Units Pharmaceutical Manufacturing Electronic Parts Manufacturing Reflow Ovens Enhanced Oil Recovery

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

2 Sentry MCL Installation, Operation & Maintenance

2 Sentry MCL Installation, Operation & Maintenance Gas Liquid & Slurry Solid & Powder Steam & Water Installation, Operation & Maintenance Manual Original Instructions Liquid Sampling Manual Low-Emission Samplers S-GA-IOM-00249-7 11-17 Sentry MCL 966 Blue

More information

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information CS-425-01 Controlled Dissolved Gas assembly with optional CS-603-01 Air Aspirator assembly Installation and Operation information Serial # CS-XXX Date of shipment:, 2005 Shipped to: Purchase order #: xxxxxxx

More information

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013 The SRI ASTM 3612/TOGA/ Dissolved Gas GC configuration ( TOGA GC ) permits measurement of gasses dissolved in water, oil or other liquids, and is based on the requirements of ASTM method 3612, option C,

More information

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Sanitizers. Sanitizers. Sanitizers for Pools & Spas Sanitizers Sanitizers for Pools & Spas 213 213 IntelliChlor Salt Chlorinator Featured Highlights IntelliChlor Salt Chlorinator IntelliChlor Salt Chlorinator uses common table salt to produce all the chlorine

More information

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist Agilent Site Preparation Infinity II Checklist Preparative HPLC System Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Agilent ICP-MS Interactive Troubleshooting tool for Low sensitivity

Agilent ICP-MS Interactive Troubleshooting tool for Low sensitivity Agilent ICP-MS Interactive Troubleshooting tool for Low sensitivity Rev. B 2017,Janyary,20 Next > Preconditions 7900, 7800, 7700, or 8800 ICP-MS is used. Sample introduction type is PeriPump. If you are

More information

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware 57007-88 Introduction Safety Precautions This instruction sheet describes how to set up and use the Hach (Figure 1). A water weir is a device that raises or diverts water to regulate the flow. Hach s water

More information

Agilent 1290 Infinity Pump Head Maintenance

Agilent 1290 Infinity Pump Head Maintenance Agilent 1290 Infinity Pump Head Maintenance Technical Note Agilent Technologies Notices Agilent Technologies, Inc. 2012-2015, 2016 No part of this manual may be reproduced in any form or by any means (including

More information

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Sanitizers. Sanitizers. Sanitizers for Pools & Spas for Pools & Spas 207 IntelliChlor Salt Chlorinator Featured Highlights IntelliChlor Salt Chlorinator IntelliChlor Salt Chlorinator uses common table salt to produce all the chlorine a pool needs, safely,

More information

Major Design Features

Major Design Features Major Design Features 3Flex Features Design Benefits Discussion 316 SS fittings and pneumatically actuated, hard-seal valves Provides virtually leak-free gas management with the lowest outgassing rate

More information

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection This user guide does not have the intention to introduce you to any of the theory and/or principles behind

More information

Valve INV-907. Instructions. 1 Introduction. 2 Installation. Safety. Unpacking. Installing the valve

Valve INV-907. Instructions. 1 Introduction. 2 Installation. Safety. Unpacking. Installing the valve Instructions 1 Introduction is a motorised rotary 7 port valve. The valve is used in ÄKTA design chromatography systems. It is powered from the ÄKTAdesign P-900 series system pump, and is controlled from

More information

Genie Supreme Model 123 Installation & Operation Instructions

Genie Supreme Model 123 Installation & Operation Instructions Genie Supreme Model 123 Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737

More information

VIC offers a variety of Calibrated Gas Leaks

VIC offers a variety of Calibrated Gas Leaks CALIBRATED GAS LEAKS VIC offers a high quality line of calibrated gas leaks traceable to National Institute of Standards Technology (NIST). Calibrated gas leaks are used to provide a controlled delivery

More information

Discovery HP-TGA 75/750. Site Preparation Guide

Discovery HP-TGA 75/750. Site Preparation Guide Discovery HP-TGA 75/750 Site Preparation Guide Revision A Issued August 2018 Table of Contents Table of Contents... 2 Ideal Setup... 3 System Components... 4 Instrument Measurements... 5 Utility Requirements...

More information

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer application Note Gas Chromatography/ Mass Spectrometry Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer Overview A mass spectrometer

More information

RD(H)20/25 Pressure-Reducing Regulator User Manual

RD(H)20/25 Pressure-Reducing Regulator User Manual RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be

More information

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax DH-40i, Rev. 04.03.02 Micro-Incubation Platform For RC-40 Chambers Model DH-40i 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax DH-40i, Rev. 04.03.02 Table of

More information

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly Technical Information CCS240 and CCS241 Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Chlorine dioxide is used for disinfection

More information

CAPITAL CONTROLS SERIES NXT3000

CAPITAL CONTROLS SERIES NXT3000 CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing

More information

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2. STANDARD OPERATING PROCEDURES Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.5 ) Sampler (RAAS) AMBIENT AIR MONITORING PROGRAM for the 130 LIBERTY STREET DECONSTRUCTION

More information

6890 GC Site Preparation

6890 GC Site Preparation 6890 GC Site Preparation (a16011) This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this material. The information

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

Installation Operation Maintenance

Installation Operation Maintenance 682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description

More information

16 Ideal for standard laboratory chromatography. 19 High temperature columns ideal for flow chemistry

16 Ideal for standard laboratory chromatography. 19 High temperature columns ideal for flow chemistry Omnifit Labware 2 CONTENTS Solvent Safety Bottle Caps 4 Bottle Caps Selection Guide Q-Series Solvent Bottle Caps 6 1/4"-28 UNF threaded inlet lines with optional on-off valves T-Series Solvent Bottle Caps

More information

Inert Air (N2) Systems Manual

Inert Air (N2) Systems Manual INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing

More information

Mass Spec will not Autotune

Mass Spec will not Autotune Mass Spec will not Autotune Applies to 5973A/N MSD What could be the problem? There could be several things that would cause your Mass Spec not to Autotune. The most common, easily corrected Autotune problems

More information

User s Guide. Vacuum Controller for liquid delivery systems

User s Guide. Vacuum Controller for liquid delivery systems Flow Control User s Guide Vacuum Controller for liquid delivery systems Precise Vacuum Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery

More information

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead!

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead! The «Modular Alliance» Gas Generators One step ahead! ALLIANCE, the partnership that keeps the gas flowing. F-DGSi EXPERTISE IS DEFINED BY ALWAYS BEING ONE STEP AHEAD! WE HAVE DESIGNED NEW MODULAR SOLUTION

More information

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111 INTRODUCTION Water vapor in natural gas has more than a substantial effect on the quality of the gas stream. Without quality measurement of water vapor the gas is basically not saleable. Contracts are

More information

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL Prepared by CR Manning Edited by SC Woidtke Rev August 22, 2011 PRESSURIZED WATER VESSEL OPERATING MANUAL 1. Background 1.1 The Pressurized

More information

Best Practice for Identifying Leaks in GC and GC/MS Systems

Best Practice for Identifying Leaks in GC and GC/MS Systems Best Practice for Identifying Leaks in GC and GC/MS Systems Technical Overview Maintaining a leak-free GC or GC/MS system is critical for obtaining optimal system performance with reliable, reproducible,

More information

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass

More information

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101 Dextens Thermo Conductivity Sensors Type 52101, 54101, 55101 Operating Manual May 2012 Table of Content 1 GENERAL INFORMATION...4 1.1 DISCLAIMER...4 1.2 SYMBOLS AND CONVENTIONS...4 1.3 SERVICES AND REPAIRS...4

More information

SERIES 20 CHAMBERS THE RC-25 AND RC-25F CHAMBERS ASSEMBLY

SERIES 20 CHAMBERS THE RC-25 AND RC-25F CHAMBERS ASSEMBLY Series 20 Chamber Instructions Models RC-25 and RC-25F Round Coverslip Chambers SERIES 20 CHAMBERS A feature in common with all Series 20 chambers is the use of a glass coverslip for the floor of the chamber.

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI NanoSight NS300 Operation instructions Injection/flushing brief overview: 1. Do not exceed flow of 1 ml per 20 seconds. 2. Inject two 1 ml syringes with nano-pure or DI water. 3. If the water does not

More information

Filter Housings. Universal & Compact Multi-Chamber Filter Housings

Filter Housings. Universal & Compact Multi-Chamber Filter Housings Filter Housings engineer approved Universal & Compact Multi-Chamber Filter Housings White Knight dual- and quad-chamber filter housings fit standard filter cartridges offered by major suppliers. They provide

More information

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE GENERAL INFORMATION This family of dissolved oxygen electrodes is of the steam sterilizable polarographic type, designed to be interchangeable with NBS

More information

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All

More information

PERFORM Operating Document

PERFORM Operating Document PERFORM Operating Document Use and Maintenance of CO 2 Incubator PC-POD-CA-007-v03 Revision History Version Reason for Revision Date 01 New POD 30-Sep-13 02 Minor revisions for section 2.3, 3.1, 4.3. 14-April-16

More information

Rev. CO Packed Columns for Normal Phase Chromatography. TSKgel NH m INSTRUCTION MANUAL

Rev. CO Packed Columns for Normal Phase Chromatography. TSKgel NH m INSTRUCTION MANUAL Rev. CO067000 Packed Columns for Normal Phase Chromatography TSKgel NH2-100 3 m INSTRUCTION MANUAL Safety Precautions To help protect you and/or your property from potential damage, please read this manual

More information

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante810 Benchtop Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante810 benchtop dissolved oxygen

More information

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information