IMA SpA. Advancements in Isolation Technology for Aseptic Filling. Marco Preus, July 2016

Size: px
Start display at page:

Download "IMA SpA. Advancements in Isolation Technology for Aseptic Filling. Marco Preus, July 2016"

Transcription

1 IMA SpA Advancements in Isolation Technology for Aseptic Filling Marco Preus, July 2016

2 Agenda Isolation technology advantages Isolation technology cost saving Air flow circuits Case study: vials filling under 100% Nitrogen atmosphere

3 Isolation technologies advantages Increased product safety (that results in an increased product quality) Increased operator protection (in case of toxic product) Possibility to frequently perform cleaning and decontamination cycles Surrounding area in class C (FDA; EU-GMP) or D (EU- GMP only) Controlled atmosphere (see case study)

4 Isolation technologies cost saving The surrounding area in class C or D allows the following cost saving: Less time for personnel gowning Lower personnel gowning (material) Less ambient monitoring (viable/non-viable) Less air to be conditioned

5 Filling Line with 2 FD: different protection solutions Production Area 68 m2

6 Solution A: All production room in class A Traditional solution: production room completely in class A (68 m2 with LAF)

7 Solution B: Open Active RABS Solution with Open Active RABS: Class A: 20,6 m2; LAF 20,4 m2 (Total LAF41m2) Class B 27 m2 (Total 68 m2)

8 Solution C: Isolation Technology Solution with Isolator: Class A: 20,6 m2, Class C 47,4 m2 (Total 68 m2)

9 Clean Room vs RABS vs Isolator SOLUTION A CLEAN ROOM SOLUTION B OPEN RABS SOLUTION C ISOLATOR filling sorrounding filling sorrounding filling sorrounding CLASS A B A B A C Clean room area m ,6 47,4 Air changes per hour (considering the ceiling at 3m) Total air per hour Total air per day (24 hours) TOTAL AIR PER DAY (24 hours) in m Saving with respect to solution A -35,29% -64,54% Saving with respect to solution B -45,20%

10 Isolator Air Flow Circuits IMA Life isolators for filling lines are equipped with a sophisticated air flow circuit that can be subdivided in three main section: Re-circulated air flow to create the unidirectional air flow (LAF) Make-up air flow, to ensure an adequate amount of new air in the loop Extraction air flow, to have a fine pressure adjustment inside each isolator chamber

11 Re-circulation Air Flow It is a closed loop composed by inlet fans and inlet filters (HEPA H14) in charge of the generation of the unidirectional air flow (LAF) inside the isolator. Hepa filter with Bag-in Bag-out Recirculation Fan Air recirculation ducts At the bottom of each isolator section, all air is extracted by the fans in charge of the recirculation, and reintroduced in the isolator chamber via the filtration stage. Machine base LAF Fan LAF Filter

12 Make-up Air Flow HVAC EXTRACTION UNIT We just need to extract and makeup approx. 20% of the total amount of air, to keep the right Humidity and Temperature levels.

13 Extraction Air Flow This circuit is in charge of the fine pressure control. Large HVACs have a high response time when a modification in the air flow (pressure, speed, ) is required, due to its size and related inertia. Through this extraction pipe, the main control system is able to ensure a very fast and precise pressure control for each single section. Exhaust

14 Case study: vials filling under 100% Nitrogen atmosphere Filling Line specification: Small batches: vials per batch Filling speed: 70 VPM Single format: 5 ml Multiple filling volumes: 1.5, 3, 5 ml Extremely expensive products 100% IPC Aseptic, NON-toxic product

15 Case study: vials filling under 100% Nitrogen atmosphere Filling Line specification: Small batches: vials per batch Filling speed: 70 VPM Single format: 5 ml Multiple filling volumes: 1.5, 3, 5 ml Extremely expensive products 100% IPC Aseptic, NON-toxic product Customer requirements: Isolation technology with CLASS C background Oxygen residual inside the vials close to 0%

16 Case study: vials filling under 100% Nitrogen atmosphere 1. Nitrogen purging station 2. Nitrogen flushing of the complete isolator

17 1. Nitrogen purging 1 st step: Vials are purged with nitrogen before and after filling

18 1. Nitrogen purging 2 nd step: Filled vials are flushed with nitrogen up to the capping station Tunnel to flush the filled vials with nitrogen

19 1. Nitrogen purging 3 rd step: A concentrated nitrogen cloud is created around the capping area Nr. 2 nitrogen ejectors

20 2. Complete filling isolator is pressurized with nitrogen Accumulation table area Standard air flow Capping area Standard air flow Filling & Stoppering area 100% Nitrogen flow

21 Isolator pressure cascade Accumulation Table + 55 Pa Tunnel cooling zone + 45 Pa Filling & Stoppering + 60 Pa N2 Capping + 45 Pa Air trap + 0 Pa Room + 30 Pa Room + 15 Pa

22 Isolator pressure cascade AIR AIR N 2 AIR AIR +N 2 N 2 N 2 AIR +N 2 AIR Exhaust + 45 Pa Tunnel cooling zone Exhaust + 55 Pa Accumulation Table N2 recycling + 60 Pa Filling & Stoppering Exhaust + 45 Pa Capping + 0 Pa Air trap

23 Residual O 2 results Nitrogen vial flushing (only): Approx. 1% of residual O 2 Difficult validation procedure: O 2 analysis on samples Nitrogen vial flushing + Complete isolator nitrogen flushing: <1% forwarding to 0% of residual O 2 Easier validation approach, due to the possibility to monitor the O 2 level inside the isolator

24 IMA portfolio for aseptic filling single stop shopping..

25 ANY QUESTIONS? Marco Preus Isolation technology Product manager Shane Sipthorp Selpak

H 2 O 2 Bio-Decontamination and Aseptic Transfer of Heat Sensitive Materials Sergio Mauri, Director, Global Marketing and Business Intelligence

H 2 O 2 Bio-Decontamination and Aseptic Transfer of Heat Sensitive Materials Sergio Mauri, Director, Global Marketing and Business Intelligence H 2 O 2 Bio-Decontamination Process and Aseptic Transfer of Heat Sensitive Materials Sergio Mauri, Director, Global Marketing and Business Intelligence Presentation Outline Surface bio-decontamination

More information

Whitepaper Technical Opinion: Grade A - Air Supply and Local Protection

Whitepaper Technical Opinion: Grade A - Air Supply and Local Protection Whitepaper Technical Opinion: Grade A - Air Supply and Local Protection I N D U S T R Y I N S I G H T S Norman A. Goldschmidt Sr. Principal, President www.geieng.com I N D U S T R Y I N S I G H T S Genesis

More information

OEL LIMITS: Products are classified according to hazards levels that correspond to these five OEL levels as shown in the chart below :

OEL LIMITS: Products are classified according to hazards levels that correspond to these five OEL levels as shown in the chart below : Isolator Integrity Leak-Testing Four level classification system of hourly leak rate Class Hourly Leak Rate Rh h -1 Pressure Integrity Test Methods 1 < 5 * 10-4 High Oxygen method, Pressure change method

More information

with the Use of RABS and Isolators Barcelona, Spain October 27, 2015

with the Use of RABS and Isolators Barcelona, Spain October 27, 2015 Aseptic Processing Barrier Technology Trends with the Use of RABS and Isolators Barcelona, Spain October 27, 2015 Jack Lysfjord, Principal Consultant 952 546 2082 jlysfjord@q.com Agenda Background - Diagrams

More information

1 5 2 Definition of Isolator Technology Isolator Types and Applications 3 Critical Design Considerations 4 Biodecontamination Conclusion and Summary 2

1 5 2 Definition of Isolator Technology Isolator Types and Applications 3 Critical Design Considerations 4 Biodecontamination Conclusion and Summary 2 Isolator Technology for Aseptic Manufacturing May 29, 2015 1 1 5 2 Definition of Isolator Technology Isolator Types and Applications 3 Critical Design Considerations 4 Biodecontamination Conclusion and

More information

ProSys Laboratory Analytical Isolators

ProSys Laboratory Analytical Isolators Custom and standard isolators for analytical and QA laboratories Contained handling of samples for dispensing and analysis Integration of a wide range of different weigh scale systems and other instrumentation

More information

Regulatory Basics for Facility Design (WHO GMP): Current GMP Requirements

Regulatory Basics for Facility Design (WHO GMP): Current GMP Requirements Regulatory Basics for Facility Design (WHO GMP): Current GMP Requirements Main Topics of the Presentation Clean Room Requirements Interior Finishes and Air Tightness of Clean Rooms Pressure Cascade Concept

More information

CTG Certification Protocol -- Version 3.0 SUMMARY

CTG Certification Protocol -- Version 3.0 SUMMARY Date of Test: Test Report Number: SUMMARY Date of Prior Certification: Certified by: Re-certification Due Date: Unit Description: Make : Model: Serial Number: Location: CERTIFIER INFORMATION Name: Client

More information

Walk in Modular Material Transfer Chamber Including Integration of a Bioquell Clarus L2 hydrogen peroxide vapour (HPV) generator

Walk in Modular Material Transfer Chamber Including Integration of a Bioquell Clarus L2 hydrogen peroxide vapour (HPV) generator Walk in Modular Material Transfer Chamber Including Integration of a Bioquell Clarus L2 hydrogen peroxide vapour (HPV) generator Page 1 of 20 Walk in chamber and HPV integrated system - Product overview.

More information

Sole reliance for sterility or other quality aspects must not be placed on finished product test.

Sole reliance for sterility or other quality aspects must not be placed on finished product test. This chapter provides requirements for aseptic production in the manufacture and quality control of veterinary vaccines in accordance with Chapter 1.1.8 Principles of veterinary vaccine production and

More information

Guideline to the Inspection of Hormone Product Manufacturing Facilities QAS/08.256, February 2008

Guideline to the Inspection of Hormone Product Manufacturing Facilities QAS/08.256, February 2008 13 May 2008 Quality Assurance Programme Quality Assurance and Safety: Medicines (QSM) Department of Medicines Policy and Standards (PSM) World Health Organization CH-1211 Geneva 27 Switzerland Guideline

More information

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS. A high-capacity EBA system [CSVS] [main purge]

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS. A high-capacity EBA system [CSVS] [main purge] PAGE : 1 / 9 5. CONTAINMENT PURGE (EBA [CSVS]) The Reactor Building purge system comprises the following: A high-capacity EBA system [CSVS] [main purge] A low-capacity EBA system [CSVS] [mini-purge] 5.1.

More information

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION ISOLATORS OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION Aseptic Isolators Extract Technology is a leading supplier of containment and aseptic systems for the pharmaceutical and biotech markets. We have

More information

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION ISOLATORS OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION Aseptic Isolators Extract Technology is a leading supplier of containment and aseptic systems for the pharmaceutical and biotech markets. We have

More information

Facility design for containment. Gordon Farquharson, July 2016

Facility design for containment. Gordon Farquharson, July 2016 Facility design for containment Gordon Farquharson, July 2016 Agenda Understanding the hazards. Containment principles. Primary and secondary containment. Facility features: Layout & Air locks. Pressurisation.

More information

In summary, the ISPE comments suggest the following additional improvements to the modified Annex 1 document:

In summary, the ISPE comments suggest the following additional improvements to the modified Annex 1 document: 28 April 2006 To: Ms. Sabine Atzor, European Commission, Brussels Mr. David Cockburn, EMEA, London Via e-mail to: sabine.atzor@cec.eu.int david.cockburn@emea.eu.int Doc. Ref: EMEA/INS/GMP/318222/2005,

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100 Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet

More information

Application Note 13: Electron Microscope Decontamination

Application Note 13: Electron Microscope Decontamination The Chlorine Dioxide People Providing you with gaseous chlorine dioxide solutions for your decontamination needs Application Note 13: Electron Microscope Decontamination M Uses: An electron microscope

More information

Glove Management. PDA Ireland Chapter Dublin 04 th Oct Dr. Aidan Harrington DPS Group

Glove Management. PDA Ireland Chapter Dublin 04 th Oct Dr. Aidan Harrington DPS Group Glove Management PDA Ireland Chapter Dublin 04 th Oct 2018 Dr. Aidan Harrington DPS Group Agenda Regulatory Requirements Glove Integrity & Contamination Control Current Practices for Glove Management Benchmarking

More information

Straw CO 2 Leak Testing

Straw CO 2 Leak Testing Straw CO 2 Leak Testing 1 Preparation of the Straws (Brief) The ABS end pieces printed on a Fermilab 3D printer are cleaned in an ultrasonic cleaner with isopropyl alcohol or ethanol (either works well

More information

Ad Hoc GMP Inspections Services Group EC GUIDE TO GOOD MANUFACTURING PRACTICE REVISION TO ANNEX 1

Ad Hoc GMP Inspections Services Group EC GUIDE TO GOOD MANUFACTURING PRACTICE REVISION TO ANNEX 1 EUROPEAN COMMISSION ENTERPRISE DIRECTORATE-GENERAL Single market : management & legislation for consumer goods Pharmaceuticals : regulatory framework and market authorisations Brussels, 30 May 2003 Ad

More information

Air Handling Unit (AHU) Air handling unit which serves to condition the air and provide the required air movement within a facility.

Air Handling Unit (AHU) Air handling unit which serves to condition the air and provide the required air movement within a facility. IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 13, Issue 5 Ver. I (Sep. - Oct. 2016), PP 28-35 www.iosrjournals.org. Heating, Ventilation and Air

More information

Annex 8. Guidelines on heating, ventilation and air-conditioning systems for non-sterile pharmaceutical products. Background. Summary of main changes

Annex 8. Guidelines on heating, ventilation and air-conditioning systems for non-sterile pharmaceutical products. Background. Summary of main changes Annex 8 Guidelines on heating, ventilation and air-conditioning systems for non-sterile pharmaceutical products Background The World Health Organization (WHO) published the first edition of the WHO Guidelines

More information

VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS

VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS Air Quality Working Group Information Package - Part 7 of 12 December 2018 Doc No. AQWG_5_0.08 Page 1 of 12 Ventilation during Tunnel Construction

More information

JetVent SAFE, AUTOMATIC PRESSURIZED CONTAINMENT.

JetVent SAFE, AUTOMATIC PRESSURIZED CONTAINMENT. JetVent SAFE, AUTOMATIC PRESSURIZED CONTAINMENT. PROTECTING PEOPLE AND THEIR ENVIRONMENTS FROM EXPOSURE. Handling today s higher-potency active pharmaceutical ingredients (HPAPIs) presents ever-increasing

More information

GOOD MANUFACTURING PRACTICES FOR HEATING, VENTILATION AND AIR-CONDITIONING SYSTEMS FOR NON-STERILE PHARMACEUTICAL DOSAGE FORMS: PART 2

GOOD MANUFACTURING PRACTICES FOR HEATING, VENTILATION AND AIR-CONDITIONING SYSTEMS FOR NON-STERILE PHARMACEUTICAL DOSAGE FORMS: PART 2 February 2018 Draft document for comment 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 GOOD MANUFACTURING PRACTICES FOR HEATING, VENTILATION

More information

GUIDELINES ON HEATING, VENTILATION AND AIR-CONDITIONING SYSTEMS FOR NON-STERILE PHARMACEUTICAL PRODUCTS

GUIDELINES ON HEATING, VENTILATION AND AIR-CONDITIONING SYSTEMS FOR NON-STERILE PHARMACEUTICAL PRODUCTS July 2017 Revised document for comment 1 2 3 4 5 6 7 8 GUIDELINES ON HEATING, VENTILATION AND AIR-CONDITIONING SYSTEMS FOR NON-STERILE PHARMACEUTICAL PRODUCTS (June 2017) REVISED DRAFT FOR COMMENT 9 10

More information

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system Bulletin 061013 TCR-104 & 109 Filling and adding to the Glycol pressure system 1. Glycol System and air On this model the glycol system is a closed system, the glycol is not exposed to the air. No external

More information

Reclaim Basic Set Up

Reclaim Basic Set Up This purpose of the document is to simplify the set up and understand the Gas Services reclaim system functions. The Gas Services Reclaim Manual is to be used for reference, maintenance, and servicing.

More information

1.060 Set-Up and Priming of the Bypass Circuit. Perfusion Technology Department. Perfusionists

1.060 Set-Up and Priming of the Bypass Circuit. Perfusion Technology Department. Perfusionists TITLE/DESCRIPTION: DEPARTMENT: PERSONNEL: 1.060 Set-Up and Priming of the Bypass Circuit Perfusion Technology Department Perfusionists EFFECTIVE DATE: 8/97 REVISED: 09/07, 04/09, 9/17 PURPOSE: The function

More information

EuroBioConcept s.a.s Hospital Pharmacy Isolator Systems

EuroBioConcept s.a.s Hospital Pharmacy Isolator Systems EuroBioConcept s.a.s Hospital Pharmacy Isolator Systems Presented by: Joe Sacca Dynamic Design Pharma, Inc. Mission Viejo, California USA June 2014 INTRODUCTION EBC PRODUCTS TYPICAL INSTALLATIONS ISOLATION

More information

OPERATING MANUAL LO-CROSS-FLOW CF M

OPERATING MANUAL LO-CROSS-FLOW CF M VA FILTRATION USA 110 Dodd Court American Canyon, CA 94503 Tel : (707) 552 2616 Fax :(707) 552 3871 Web : www.vafiltration.com OPERATING MANUAL LO-CROSS-FLOW CF8-2-200M January, 2017 TECHNICAL SPECIFICATIONS

More information

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions VS18/26 with PROFINET and EtherNet/IP Interface ATEX Installation Instructions INDEX 1. INTENDED USAGE 3 2. OPERATING MANUAL ATEX 4 2.1 General conditions 4 2.2 Installation 5 2.3 Operating 5 2.4 Failures

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are

More information

IC Sentinel Applications Guide for Healthcare Environmental Air Quality Monitoring

IC Sentinel Applications Guide for Healthcare Environmental Air Quality Monitoring IC Sentinel Applications Guide for Healthcare Environmental Air Quality Monitoring IC Sentinel is a real-time environmental quality monitoring solution, comprised of facilitywide, low-cost, compact, multi-sensor

More information

Field Evaluation of ASTM E in Relation to Control Room Habitability Testing and Boundary Maintenance in Nuclear Power Plants.

Field Evaluation of ASTM E in Relation to Control Room Habitability Testing and Boundary Maintenance in Nuclear Power Plants. Field Evaluation of ASTM E741-00 in Relation to Control Room Habitability Testing and Boundary Maintenance in Nuclear Power Plants. Presented By Clinton B. Summers Eric M. Banks NUCON International, Inc.

More information

SAMPLING SYSTEMS FOR LIQUIDS, GASES AND OTHERS APPLICATIONS.

SAMPLING SYSTEMS FOR LIQUIDS, GASES AND OTHERS APPLICATIONS. SAMPLING SYSTEMS FOR LIQUIDS, GASES AND OTHERS APPLICATIONS. SAMPLING SYSTEMS CONTENTS 1. SAMPLING SYSTEMS OVERVIEW...Pag. 3-4 2. LIQUID SAMPLING SYSTEM ESV SERIES ESV STANDARD CONFIGURATION...Pag. 5-6

More information

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications 1800350/6 IM-P180-12 ST Issue 6 BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications Installation and Maintenance Instructions 1. Safety information 2. General

More information

Transfeu WP2 Subtask Development of small-scale test method for fire effluents

Transfeu WP2 Subtask Development of small-scale test method for fire effluents Pagina 83 di 89 Transfeu WP2 Subtask 2.1.2 Development of small-scale test method for fire effluents Step 2: Influence of 2 nd filter on FTIR sampling line to prevent HCl and other halogen gases trapping

More information

NGN Series nitrogen generator

NGN Series nitrogen generator NGN Series 8-64 nitrogen generator Applications how it works RK series 5-40 F Blanketing of Chemicals and Pharmaceuticals Gas Assisted Injection Moulding (GAIM) Laser Cutting Food Heat Treament of Ferrous

More information

ASSESSMENT OF BIOAEROSOL REDUCTION METHODS IN STEM CELL TRANSPLANT UNITS AT A UNIVERSITY HOSPITAL

ASSESSMENT OF BIOAEROSOL REDUCTION METHODS IN STEM CELL TRANSPLANT UNITS AT A UNIVERSITY HOSPITAL ASSESSMENT OF BIOAEROSOL REDUCTION METHODS IN STEM CELL TRANSPLANT UNITS AT A UNIVERSITY HOSPITAL T. S. Alderman, MS, W.R. Thomann, Dr.P.H., D.L. Hunt, Dr.P.H. Duke University Medical Center INTRODUCTION

More information

Title: Contaminated Equipment

Title: Contaminated Equipment Procedure No.: WYN032.046 Page: 1 of 6 Preparer: Owner: Approver: Site Safety Coordinator Site Safety Coordinator Ecology Services Manager 1. PURPOSE To set forth the requirements at the BASF Corporation

More information

Airborne Activity Sampling and Monitoring at Hinkley Point A Site. David Williams, Hinkley Point A Site

Airborne Activity Sampling and Monitoring at Hinkley Point A Site. David Williams, Hinkley Point A Site Airborne Activity Sampling and Monitoring at Hinkley Point A Site David Williams, Hinkley Point A Site Presentation objectives Ventilation controls in use at Hinkley Point A Site The air sampling and monitoring

More information

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings CAT.E832- A Air Suction Filter In-line Type with One-touch Fittings Series ZFC An in-line type air suction filter that prevents trouble in vacuum equipment due to contaminants in the air IN/OUT straight

More information

Environmental and Safety Concerns with SF 6 Gas

Environmental and Safety Concerns with SF 6 Gas DILO 2 nd Annual SF6 Gas Management Seminar Tampa FL, November 2017 Environmental and Safety Concerns with SF 6 Gas Patrick Di Lillo Technical Specialist Consolidated Edison Co. of NY, Inc. November 16,

More information

DESIGN AND INSTALLATION CONSIDERATIONS FOR TSI AEROTRAK VHP-RESISTANT REMOTE PARTICLE COUNTERS

DESIGN AND INSTALLATION CONSIDERATIONS FOR TSI AEROTRAK VHP-RESISTANT REMOTE PARTICLE COUNTERS DESIGN AND INSTALLATION CONSIDERATIONS FOR TSI AEROTRAK VHP-RESISTANT REMOTE PARTICLE COUNTERS APPLICATION NOTE CC-111 (A4) Introduction A widely used method to inactivate bio-contamination on surfaces

More information

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types 19 th World Conference on Non-Destructive Testing 2016 Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types Klaus HERRMANN 1, Daniel WETZIG

More information

Using Vaporized Hydrogen Peroxide

Using Vaporized Hydrogen Peroxide for Bio-Decontamination D-111046-2013 Using Vaporized Hydrogen Peroxide In 1994, Dräger introduced the first electrochemical hydrogen peroxide (H2O2) sensor for monitoring low concentrations of vaporized

More information

29 CFR CONFINED SPACE ENTRY

29 CFR CONFINED SPACE ENTRY 29 CFR 1910.146 CONFINED SPACE ENTRY http://esf.uvm.edu/sirippt/powerpt.html 6/5/2000 Marvin Menesini What is a Confined Space? A space that: Is large enough and so configured that an employee can enter

More information

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation Ruskinn Hypoxia and Anoxia Workstations The Ruskinn range of hypoxia workstations has been designed to replicate low oxygen in vivo physiology providing the ideal research platform for cell biologists

More information

Keeping anaesthetic pollution to minimum in theatre environment

Keeping anaesthetic pollution to minimum in theatre environment Vet Times The website for the veterinary profession https://www.vettimes.co.uk Keeping anaesthetic pollution to minimum in theatre environment Author : Gianluca Bini Categories : General, Vets Date : September

More information

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE

More information

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Entry to these spaces must be rigorously controlled to prevent serious injury or death. Chapter 6 - Confined Spaces Chapter 6 Confined Spaces Definitions A confined space is defined as any structure that must be entered and that has or may contain dangerous concentrations of hazardous gases

More information

Related Products: Auto Drain Valve. Model/Specifications. Model

Related Products: Auto Drain Valve. Model/Specifications. Model Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl

More information

Choosing and Installing Microbiological Safety Cabinets

Choosing and Installing Microbiological Safety Cabinets Choosing and Installing Microbiological Safety Cabinets Guidance for University Departments and Functions First Edition December 2006 Safety Services Office Issued with the approval of the Biological and

More information

Safety Manual Section 6 Confined Space

Safety Manual Section 6 Confined Space 6. CONFINED SPACE ENTRY Introduction The following sections provide general guidelines and procedures for confined space entry. This section covers the following topics: Topic Page 6.1 Types of s... 6-2

More information

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference! Z11.0.1X.6C-18 Mounting and Operating Manual Atmospheric Oxygen Sensor Element GOEL 370, GOEL 381 Please read these instructions carefully before use! Please consider the safety instructions! Please keep

More information

Precise Controlled Atmosphere Glove Boxes and Precise Basic Glove Boxes

Precise Controlled Atmosphere Glove Boxes and Precise Basic Glove Boxes User s Manual Precise Controlled Atmosphere Glove Boxes and Precise Basic Glove Boxes CA Models Voltage, Frequency 5220100 115V, 60 Hz 5220120 230V, 50 Hz 5220121 230V, 60 Hz 5220130 100V, 50 Hz 5220131

More information

Pressure Transmitters 36 F-27839

Pressure Transmitters 36 F-27839 Pressure Transmitters 36 F-27839 SPD310/SPD360 Air Differential schneider-electric.com 37 SPD310/SPD360 SPD310/SPD360 differential pressure transmitters are intended for use in air handling systems for

More information

A Quantitative Study in Cross Contamination

A Quantitative Study in Cross Contamination A Quantitative Study in Cross Contamination This article is based on data acquired during an evaluation of the quantifiable risk of cross contamination in an Oral Solid Dosage (OSD) facility. This article

More information

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING

More information

Transfer Procedures. By the end of this chapter, you will be able to: The Transfer Process. Chapter 12

Transfer Procedures. By the end of this chapter, you will be able to: The Transfer Process. Chapter 12 Chapter 12 Transfer Procedures By the end of this chapter, you will be able to: l Explain the term transfer process l Name two types of sanitisation methods often used l Describe the spray and wipe technique

More information

Ir HN Lam BSc(Eng), MSc(Eng), CEng, MIMechE, MCIBSE, MASHRAE, MASME, MHKIE. Test Report on Non-Return Valve for Water Closets

Ir HN Lam BSc(Eng), MSc(Eng), CEng, MIMechE, MCIBSE, MASHRAE, MASME, MHKIE. Test Report on Non-Return Valve for Water Closets c/o Department of Mechanical Engineering University of Hong Kong Pokfulam Road Hong Kong Phone: 28592640 E-mail: hn.lam.hku@hku.hk Ir HN Lam BSc(Eng), MSc(Eng), CEng, MIMechE, MCIBSE, MASHRAE, MASME, MHKIE

More information

Safety Services. Introduction

Safety Services. Introduction Safety Services Guidance on the Selection, Installation, Maintenance and Operation of Microbiological Safety Cabinets for use in containment level 2 (CL2) laboratories Introduction 1. Microbiological safety

More information

Aseptic Processing Achieving Sterility by Design

Aseptic Processing Achieving Sterility by Design Aseptic Processing Achieving Sterility by Design James Agalloco Agalloco & Associates FDA Aseptic Perspective In an aseptic process, the drug product, container, and closure are first subjected to sterilization

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

Draft. Equipment/Instrument

Draft. Equipment/Instrument Heating Ventilation Air Conditioning (HVAC) Technical Platform Recommended specialist equipment including instruments for those working with Healthcare Ventilation Systems Those working with Healthcare

More information

NGP-250/500 Nitrogen Generator Quick Start Guide

NGP-250/500 Nitrogen Generator Quick Start Guide NGP-250/500 Nitrogen Generator Quick Start Guide Version: A July 2013 Potter Electric Signal Company, LLC 5757 Phantom Dr., Suite 125 P. O. Box 42037 Hazelwood, MO 63042 Phone: (314) 595-6900 Document

More information

NuAire Model NU NR797 Negative Pressure Recirculating Compounding Aseptic Containment Isolator Performance Evaluation Compliance to USP797

NuAire Model NU NR797 Negative Pressure Recirculating Compounding Aseptic Containment Isolator Performance Evaluation Compliance to USP797 TECHNICAL BULLETIN : GENERAL INFORMATION NuAire Model NU NR797 Negative Pressure Recirculating Compounding Aseptic Containment Isolator Performance Evaluation Compliance to USP797 Background The United

More information

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual EMISSION CHAMBERS Bulk and Surface Emission Detection for the RAD7 User Manual TABLE OF CONTENTS INTRODUCTION 3 1 SYSTEM CONFIGURATION 4 1.1 Closed Loop Configuration 4 Fig. 1 Emission Chamber Closed Loop

More information

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces 1. SCOPE This document now includes provision for safe access to cable tunnels and culverts previously covered in PSSI 37 which is now withdrawn. The term Confined Space is defined in the Confined Spaces

More information

CLOSED LOOP SOLVENT EMISSIONS CONTROL. David C.H. Grant

CLOSED LOOP SOLVENT EMISSIONS CONTROL. David C.H. Grant CLOSED LOOP SOLVENT EMISSIONS CONTROL David C.H. Grant Abstract: An approach to closed loop solvent emissions control systems, useful for all conventional solvent processes and solvents is presented. The

More information

1. Class "A" - an environment that is immediately dangerous to life of health. (Entry by permit only shall have a posted sign.)

1. Class A - an environment that is immediately dangerous to life of health. (Entry by permit only shall have a posted sign.) City & County of Broomfield Operational Procedures for Confined Space Entry I. Purpose: To provide an outline of operations, procedures, responsibilities, and minimum safety requirements to be followed

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Installation, Operation, and Maintenance Balston 75-96 and 75-98 Nitrogen Generation System Tower Pressure Gauge 5'-1" 3'-6" 7'-4" 6'-10 1/2" PLAN VIEW Figure 1 - Balston 75-96 and

More information

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18 NITROGEN OPERATING INSTRUCTIONS NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18 READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING 3451 S. 40th Street Phoenix, AZ 85040 602.437.5020 800.223.4540 www.tsissg.com

More information

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers The PRB Coal Users Group plans to develop a Design Guide for Mill Inerting as an aid to users when designing a mill inerting system.

More information

Facility management and equipment. Institut Pasteur du Maroc

Facility management and equipment. Institut Pasteur du Maroc Facility management and equipment Institut Pasteur du Maroc 08.11.2017 1 Laboratory biosafety is the term used to describe the containment principles, technologies and practices that are implemented to

More information

Pilot Check Valve: Metal Body Type

Pilot Check Valve: Metal Body Type INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not

More information

THE UNIVERSITY OF WESTERN ONTARIO DIVISION OF HUMAN RESOURCES OCCUPATIONAL HEATH & SAFETY

THE UNIVERSITY OF WESTERN ONTARIO DIVISION OF HUMAN RESOURCES OCCUPATIONAL HEATH & SAFETY THE UNIVERSITY OF WESTERN ONTARIO DIVISION OF HUMAN RESOURCES OCCUPATIONAL HEATH & SAFETY UWO Sheep Research Facility Recertification Inspection Checklist Date: March 20, 2009 The following inspection

More information

AN EASY-TO-USE GUIDE FOR ALL BLUEPRINT PRODUCTS

AN EASY-TO-USE GUIDE FOR ALL BLUEPRINT PRODUCTS AN EASY-TO-USE GUIDE FOR ALL BLUEPRINT PRODUCTS TABLE OF CONTENTS PUCKS CHLORINE 2 STICKS CHLORINE 2 ALK INCREASER 10 PH INCREASER 10 PH DECREASER 11 CAL INCREASER 11 STABILIZE DRY 12 STABILIZE LIQUID

More information

IGO GROUP SAFETY STANDARD 30 - WORKPLACE VENTILATION INDEPENDENCE GROUP NL

IGO GROUP SAFETY STANDARD 30 - WORKPLACE VENTILATION INDEPENDENCE GROUP NL IGO GROUP SAFETY STANDARD 30 - WORKPLACE VENTILATION INDEPENDENCE GROUP NL CONTENTS 1. INTENT... 3 2. APPLICATION... 3 3. UNDERGROUND VENTILATION... 3 3.2 Underground Ventilation Officer... 3 3.3 Risk

More information

Gerard Sheridan Inspector

Gerard Sheridan Inspector Manufacture of Sterile Medicinal Products Areas of Focus for GMP Inspections GMP Information Day; 23rd October 2008. Gerard Sheridan Inspector Date : 23/10/2008 Slide 1 Objectives Highlight areas frequently

More information

MB-SP Series Solvent Purification System

MB-SP Series Solvent Purification System Operation Manual MB-SP Series Solvent Purification System Table of contents 1. System overview 2 2. Column activation.. 5 3. System purging.. 6 4. Glove box integration.... 7 5. Solvent reservoir installation....

More information

Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology

Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology Jim Woodard Vice President of Sales Bryant Woods Lead Project Engineer 4/3/18 Page 1 Objectives Impact

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome

More information

THE UNIVERSITY OF WESTERN ONTARIO OCCUPATIONAL HEATH & SAFETY

THE UNIVERSITY OF WESTERN ONTARIO OCCUPATIONAL HEATH & SAFETY THE UNIVERSITY OF WESTERN ONTARIO OCCUPATIONAL HEATH & SAFETY UWO West Valley Sheep Unit Inspection Checklist Approved by Biohazards Subcomittee: March 27, 2009 The following inspection items have been

More information

Minimum Ventilation. Bernard Green Ventilation Technical Service Manager - Asia

Minimum Ventilation. Bernard Green Ventilation Technical Service Manager - Asia Minimum Ventilation Bernard Green Ventilation Technical Service Manager - Asia Minimum Ventilation At or below set point temperature minimum ventilation Regardless of outside temperature, a certain amount

More information

Topic Sheet No. 20 Confined and restricted spaces

Topic Sheet No. 20 Confined and restricted spaces Page 1 of 5 A topic sheet prepared by IRATA International (2018) SAFETY AND HEALTH TOPIC SHEET NO. 20: CONFINED AND RESTRICTED SPACES A safety and health topic sheet aimed at raising awareness of hazards

More information

We appreciate the opportunity to submit these comments for your consideration.

We appreciate the opportunity to submit these comments for your consideration. 20 March 2018 European Medicines Agency 30 Churchill Place Canary Wharf London E14 5EU United Kingdom via email to SANTE-REVISION-OF-ANNEX-1@ec.europa.eu Dear Sir or Madam: The International Society for

More information

Installation Instructions for NP100 Series Nitrogen Control Panels

Installation Instructions for NP100 Series Nitrogen Control Panels Installation Instructions for NP100 Series Nitrogen Control Panels Installation of the Nitrogen Control Panel involves installing the rough-in box and making the necessary piping connections in accordance

More information

School of Chemistry SOP For Operation Of Glove Boxes

School of Chemistry SOP For Operation Of Glove Boxes School SOP for Operation of Glove Boxes: The following SOP provides guidelines on how to adequately and safely operating a standard laboratory glove box and its associated devices. General Information:

More information

13. Evaporative Emission Control System

13. Evaporative Emission Control System EG-62 ENGINE 3MZ-FE ENGINE 13. Evaporative Emission Control System General The construction of the evaporative emission control system has been changed to comply with the LEV-II (Low Emission Vehicle-II)

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X

More information

ECS Protector Nitrogen Inerting Vent (PAV-WN)

ECS Protector Nitrogen Inerting Vent (PAV-WN) ECS Protector (PAV-WN) U.S. Pat. No. 8,636,023, 9,526,933 and 9,717,935 B2 Specifications Stock Number: Service Pressure: Regulator Setting: System Connection: Temperature Range: Dimensions: Weight: Clear

More information

Pressure Swing Absorption Nitrogen. Generator. Lower your nitrogen cost. S-Platinum Marketing Services 百能贸易公司

Pressure Swing Absorption Nitrogen. Generator. Lower your nitrogen cost. S-Platinum Marketing Services 百能贸易公司 Pressure Swing Absorption Nitrogen S-Platinum Marketing Services 百能贸易公司 Generator Lower your nitrogen cost Pressure Swing Absorption Nitrogen Generation Structural Diagram A Air Compressor --- provide

More information

Keofitt Aseptic Sampling Bag (Pat. pend.) Item no , & User Manual

Keofitt Aseptic Sampling Bag (Pat. pend.) Item no , & User Manual Keofitt Aseptic Sampling Bag (Pat. pend.) Item no. 120500, 121000 & 122000 User Manual s o m e p e o p l e w o u l d n t g a m B l e w i t h t h e i r s a m p l e t m Introduction: Manufacturer: Keofitt

More information

KEOFITT ASEPTIC SAMPLING BAG (PAT. PEND.) Item no , & User Manual

KEOFITT ASEPTIC SAMPLING BAG (PAT. PEND.) Item no , & User Manual KEOFITT ASEPTIC SAMPLING BAG (PAT. PEND.) Item no. 120500, 121000 & 122000 User Manual S O M E P E O P L E W O U L D N T G A M B L E W I T H T H E I R S A M P L E T M INTRODUCTION: MANUFACTURER: Keofitt

More information

API 682 Mechanical Seals. Swagelok Eastern Australia & New Zealand

API 682 Mechanical Seals. Swagelok Eastern Australia & New Zealand API 682 Mechanical Seals Swagelok Eastern Australia & New Zealand API 682 Mechanical Seals Overview Previous projects completed o Plan 53A o Plan 72 / 76 o Plan 74 API 682 Mechanical Seals Overview What

More information

PROPERTY & ESTATES GROUP

PROPERTY & ESTATES GROUP PROPERTY & ESTATES GROUP SAFE WORKING PROCEDURE 2-17-04 WORKING IN CONFINED SPACES Purpose of Document This document describes SRUC s policy and procedure for working in confined spaces. It applies to

More information