UNO STAGE TOP INCUBATOR All In One Stage Top Incubator. Manual

Size: px
Start display at page:

Download "UNO STAGE TOP INCUBATOR All In One Stage Top Incubator. Manual"

Transcription

1 UNO STAGE TOP INCUBATOR All In One Stage Top Incubator Manual Vers

2 This page was left blank 2

3 Index Index PREFACE SYMBOLS DESCRIPTION... 6 SYMBOLS IN THIS MANUAL AND ON THE PRODUCT... 6 SYMBOLS ON THE PRODUCT LABEL SAFETY NOTES SYSTEM OVERVIEW... 9 UNO CONTROL UNIT BUNDLE 1) UNO-T. Overview and supplied equipment BUNDLE 2) UNO-T-H-PREMIXED. Overview and supplied equipment BUNDLE 3) UNO-T-H-CO2. Overview and supplied equipment STAGE TOP CHAMBER INSTALLATION GUIDE ASSEMBLY AND GAS CONNECTION OF THE BUBBLING COLUMN CONNECTIONS OF THE HEATING DEVICES Connection of the Chamber and of the Lid of the Incubating Chamber Connection of the Humidifier and of the Heated Tube Connection of the Objective Heater (optional) CONNECTION OF THE GAS TUBES Gas connection for UNO-T-H-PREMIXED How to use the GF Regulator Gas Connection for UNO-T-H-CO How to use the Air/CO2 Mixer CONNECTION OF THE TEMPERATURE SENSOR MINI-USB PORT Connection of a USB drive PC Connection via USB RS232 PORT PC CONNECTION VIA RS INSTALLATION OF THE STAGE TOP CHAMBER USER INTERFACE HOMEPAGE Colors meaning Changing the set point temperature Graph view SYSTEM INFORMATION SETTINGS Control Mode Open Incubator Chamber & Insert Compatible chambers Objective Heater Humidity Calibration Chamber Calibration T sensor Calibration Objective Heater Calibration Logging Alarms Display Options Brightness Calibration

4 Date & Time Visual Effects Factory Reset Password Summary Auto on/off STATUS GLANCE MODE MAINTENANCE SUPPORT SUPPORT PAGE SUPPORT CONTACTS WEB CONFERENCE FOR ASSISTANCE AND TRAINING TECHNICAL SPECIFICATIONS TROUBLESHOOTING FIGURE LIST TABLE LIST MANUAL REVISION TABLE LIST OF SPARE PARTS UNO-T-H-PREMIXED UNO-T-H-CO

5 Preface UNO STAGE TOP INCUBATOR is a Digital Temperature (and Humidity) Controller and a data log device enabling the control of the environment inside the top stage incubator and is composed by UNO CONTROL UNIT and a STAGE TOP CHAMBER. UNO CONTROL UNIT ensures the highest temperature accuracy on sample temperature by controlling simultaneously up to 6 independent channels with a modern multichannel controller. UNO CONTROL UNIT comes in three different setups: UNO-T UNO CONTROL UNIT (only) UNO-T-H-PREMIXED UNO CONTROL UNIT Humidity module Flow rate regulator for premixed gas UNO-T-H-CO2 UNO CONTROL UNIT Humidity module CO2/Air gas mixer Air Pump The OBJECTIVE HEATER is an optional device which can be purchased upon request. It ensures the absence of a heat sink when the microscope objective is in close contact with the specimen. Please contact Okolab for more information on this device. The end user can define the tolerance values, which can trigger an alarm. UNO CONTROL UNIT allows you also to log your experimental data via USB connection (or RS232 connection), using an OKOLAB software, DATALOG (purchased on request) or a third party software. Moreover, UNO CONTROL UNIT can store data on its internal memory and these data can be then downloaded on a USB stick at user request. Reading this manual is essential to familiarize yourself with the installation, the functions and the operation of the device before use. 5

6 2 SYMBOLS DESCRIPTION Symbols in this manual and on the product The following symbols identify important information to note: CAUTION or WARNING: This symbol warns you about the risk of electrical shock. CAUTION or WARNING or IMPORTANT: This symbol warns you of circumstances or practices that can affect the instrument s functionality. Please refer to accompanying documents. Tip - Supplies you with helpful suggestions. Note - Supplies you with important information to successfully setup and use the instrument. Symbols on the product label CE MARKING: This symbol indicates a product s compliance with EU legislation. PRODUCT DISPOSAL: This symbol indicates that this product must not be disposed as urban solid waste. This symbol indicates the product production date This symbol indicates the manufacturer data This symbol indicates the protection degree against ingress of solids or liquids inside the product. This symbol warns you to read the user manual before starting the device 6

7 3 SAFETY NOTES Before operating the equipment please read carefully the instructions and the safety notes. If you have any questions, please contact Okolab. The equipment must be used only as intended and described in this Manual. Equipment should be operated only by technically qualified personnel. Do not start up the equipment if some of its parts are damaged. This instrument is not intended for use in locations subject to flammable or explosive gases. Transport the equipment with care. The equipment and its internal parts can be damaged by dropping and by shock. Do not use a volatile solvent such as paint thinner to clean the instrument. Deformation or discoloration will occur. Use a soft, dry cloth to remove stains from the instrument. Not following these instructions can damage or breakdown the device and its accessories. The product labels can be found on the bottom panel of the Main Unit. Do NOT make in close contact with or breathe any gas stream whose composition is different from that of ambient air. Do not exceed the voltage indicated in this manual and on the product label. Avoid excessive induction noise, static electricity, magnetic fields. Do not expose this instrument to water or moisture. Prevent throttling and kinking of tubing. Check tubing from time to time for possible wear and tear. Check that all tubing are well inserted into connectors so they cannot slip off. This device has not been designed for use for medical applications. Install safety valves and adequate pressure regulators on gas lines before the Unit input connectors. The power cord of the unit should be unplugged from the electrical outlet when left unused for a long time period. PRESSURIZED GAS, secure all connections with hose clamps. Never exceed pressure limits, 1.8 bar for N 2 and 5 bar for CO 2. Bleed all lines before disconnecting. Wear safety goggles if needed at all the time. If the pressure regulators are not within easy sight and reach make sure there is at least one shut off valve for each line. LOW OXYGEN ATMOSPHERES and HIGH CO 2 ATMOSPHERES, never enter a room or enclosure which has a low oxygen atmosphere or a high CO 2 atmosphere because of the severe danger of suffocation. Only operate in a well-ventilated room. A small amount of gas mixture (nitrogen and carbon dioxide) leaks continuously out of the instrument and should never be allowed to build up in the room. 7

8 VENTILATION, the unit should be placed so that its location or position does not interfere with proper ventilation. Neither the gas controller nor the stream destinations should be in poorly ventilated areas. The unit should be placed far from heat sources such as open flames, radiators, heat registers, stoves, or other appliances or processes that produce heat. Do not start up the equipment if the supply cable is damaged. Connect the equipment only to a grounded mains power socket. Do not disconnect cables while in operation. Prevent metal fragments or lead wire scraps from falling inside the instrument case to avoid electric shock, fire or malfunction. Before starting, assemble the equipment far from any electrical devices. The unit should never be used where it can fall or be pushed into water. International caution symbol marks this device. It is important to read the Safety Notes before installing, using and commissioning this device, as the notes contain important information relating to safety and EMC. Not following these instructions can result in damage or breakdown of the device and its accessories. We reserve the right to make technical variations. IN NO EVENT SHALL OKOLAB S.R.L. BE LIABLE FOR ANY DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, OR LOSSES OR EXPENSES RESULTING FROM ANY DEFECTIVE PRODUCT OR THE USE OF ANY PRODUCT. 8

9 4 SYSTEM OVERVIEW This Chapter describes the provided equipment. For your UNO STAGE TOP INCUBATOR that comes in three different bundles: Bundle 1) UNO-T. Stage Top Incubator for application where only thermal control is required (no gas/no humidity), which includes (see paragraph 4.1.1): a. UNO CONTROL UNIT b. Stage Top Chamber Bundle 2) UNO-T-H-PREMIXED. Stage Top Incubator for application with pre-mixed gas, which includes (see paragraph 4.1.2): a. UNO CONTROL UNIT b. Humidity module c. Flow rate regulator for premixed gas d. Stage Top Chamber Bundle 3) UNO-T-H-CO2. Stage Top Incubator for application with 100% CO2/Air mixer, for application with 100% CO2 and background Air, which includes (see paragraph 4.1.3): a. UNO CONTROL UNIT b. Humidity module c. CO2/Air gas mixer d. Air Pump e. Stage Top Chamber UNO CONTROL UNIT Figure 1 shows the UNO CONTROL UNIT overview; with reference to the highlighted pointers: 1. MINI-USB port. It allows to connect the UNO CONTROL UNIT to a PC via USB or to a USB stick, see paragraph RS 232 port. It allows to connect the UNO CONTROL UNIT to a PC via USB or to a USB drive, see paragraph Power Input. 4. Base/lid. It is the power outlet for the Chamber s Base and Lid, see paragraph Humidifier/Objective Heater. It is the power outlet for the Humidifier/Bubbling Column and the Objective Heater(optional), see paragraph Heated Tube. It is the power outlet for the Heated Tube, see paragraph Temperature Sensor port. It allows to connect the Temperature Sensor to UNO CONTROL UNIT, see paragraph ON/OFF button. 9

10 Figure 1. UNO CONTROL UNIT overview. 10

11 4.1.1 BUNDLE 1) UNO-T. Overview and supplied equipment The equipment that comes with UNO-T is composed by: 1. T-Sensor 2. UNO CONTROL UNIT (see paragraph 4.1) 3. Y-CABLE-1 (see paragraph 5.2.1) 4. Objective Heater (optional) 5. STAGE TOP CHAMBER (see paragraph 4.2) 6. Power adapter (voltage: 24V; max power consumption: 110W; max current: 4.6A) 7. MINI-USB-OTG (see paragraph 5.5) Figure 2. UNO-T. 11

12 4.1.2 BUNDLE 2) UNO-T-H-PREMIXED. Overview and supplied equipment The equipment that comes with UNO-T-H-PREMIXED is composed by: 1. T-Sensor 2. UNO CONTROL UNIT (see paragraph 4.1) 3. GF-REGULATOR (see paragraph and ) 4. TUBE-C (see Table 1) 5. Humidifier 6. Heated Tube (see paragraph 0) 7. Objective Heater (optional) 8. STAGE TOP CHAMBER 9. Y-CABLE-1 (see paragraph 5.2.1) 10. Y-CABLE-2 (see paragraph 5.2.2) 11. Power adapter (voltage: 24V; max power consumption: 110W; max current: 4.6A) 12. MINI-USB-OTG (see paragraph 5.5) Figure 3. UNO-T-H-PREMIXED. Description Photo TUBE-C (X1) Composed tube 300 cm long: Transparent PU O.D. 6mm I.D. 4mm, Length 200 cm + Plastic Connector Promepla 4,8-3,2. + Sil O.D. 7mm I.D. 4mm, Length 50 cm + PTFE 0.2 micron + Sil O.D. 7mm I.D. 4mm, Length 50 cm Table 1. Tubes for UNO-T-H-PREMIXED. 12

13 4.1.3 BUNDLE 3) UNO-T-H-CO2. Overview and supplied equipment The equipment that comes with UNO-T-H-CO2 is composed by: 1. OKO-AP (Air Pump) (see paragraph and ) 2. TUBE-A (see Table 2) 3. 2GF-MIXER (Gas Manual Mixer to mix Air and CO2) (see paragraph and ) 4. Pressure Gauge (see paragraph 5.3.2) 5. TUBE-A (see Table 2) 6. TUBE-C (see Table 2) 7. Glass Bottle - Humidifying Module (attention: FRAGILE) 8. Heated Tube (see paragraph 0) 9. Objective Heater (optional) 10. STAGE TOP CHAMBER 11. Y-CABLE-1 (see paragraph 5.2.1) 12. Y-CABLE-2 (see paragraph 5.2.2) 13. Power adapter (voltage: 24V; max power consumption: 110W; max current: 4.6A) 14. UNO CONTROL UNIT (see paragraph 4.1) 15. MINI-USB-OTG (see paragraph 5.5) 16. T-Sensor Figure 4. UNO-T-H-CO2. 13

14 Description Tube-A (X2) Single Tube 300 cm long: Transparent PU O.D. 6 mm I.D. 4mm, Length 300 cm. Photo TUBE-C (X1) Composed tube 300 cm long: Transparent PU O.D. 6mm I.D. 4mm, Length 200 cm + Plastic Connector Promepla 4,8-3,2. + Sil O.D. 7mm I.D. 4mm, Length 50 cm + PTFE 0.2 micron + Sil O.D. 7mm I.D. 4mm, Length 50 cm Table 2. Tubes for UNO-T-H-CO2. 14

15 STAGE TOP CHAMBER For the equipment description of the Stage Top Chamber, refer to the dedicated attached Stage Top Chamber manual. 5 INSTALLATION GUIDE Assembly and Gas connection of the Bubbling Column The bubbling column comes with UNO-T-H-PREMIXED and UNO-T-H-CO2; follow the instructions below to correctly assemble it (see Figure 5): 1. Unscrew the red cap with O-ring and the head of the bubbling column from the bottle, without removing the head from the plug. 2. Insert filter into the silicone tubing. Connect the silicone tubing to port of the head of the bubbling column on the inside of the red screw cap. Figure 5. Assembly instruction of the Bubbling Column and its parts. Follow the instructions below to correctly connect the gas tubes to the Bubbling Column (see Figure 6): 1. Plug the silicon end of TUBE-C to the Bubbling Column inlet (metal plug). 2. Push the Heated Tube from the PU end (yellow tube) all the way in to the push-to-fit Bubbling column output. 3. Secure the Heated Tube silicon end to the chamber, making sure the tube is all the way in. 15

16 Figure 6. Gas connections of the bubbling column. Connections of the heating devices This section describes how to connect the heating devices to UNO CONTROL UNIT Connection of the Chamber and of the Lid of the Incubating Chamber Follow the instructions below to connect the Chamber and the Lid of the Incubating Chamber to UNO CONTROL UNIT (see Figure 7): 1. Connect the Y-CABLE-1 to power output of Base and Lid on the back panel of UNO CONTROL UNIT. The power output for the Chamber and for the Lid is the one on the left, labeled Base/Lid; 2. Connect the Chamber electric cable to its connector on the Y-CABLE-1 (Chamber color label is red); 3. Connect the Lid electric cable to its connector on the Y-CABLE-1 (Lid color label is yellow). Figure 7. Chamber and Lid of the Incubating Chamber connection. 16

17 5.2.2 Connection of the Humidifier and of the Heated Tube Follow the instructions below to connect the Humidifier and the Heated Tube of the Incubating Chamber to UNO CONTROL UNIT (see Figure 8): 1. Connect the Y-CABLE-2 to power output of Humidifier and Heated Tube on the back panel of UNO CONTROL UNIT. The power output for the Humidifier and for the Heated Tube is the one in the middle, labeled Humidifier/Heated Tube; 2. Connect the Humidifier cable to its connector on the Y-CABLE-2 (Humidifier color label is green); 3. Connect the Heated Tube cable to its connector on the Y-CABLE-2 (Heated Tube color label is gray). Figure 8. Humidifier and Heated Tube connection. 17

18 5.2.3 Connection of the Objective Heater (optional) To connect the Heater Tube to UNO CONTROL UNIT, connect the Objective Heater on the back panel of UNO CONTROL UNIT. The power output for the Objective Heater is the one on the right, labeled Objective Heater (see Figure 9). Figure 9. Objective Heater connection. The cables connecting heating devices are not only color coded, but there is also a label glued to their end. Connection of the gas tubes Gas connection for UNO-T-H-PREMIXED UNO-T-H-PREMIXED works for application with pre-mixed gas. To make the gas flow into the chamber the steps are the following: 1. Connect your Premixed Gas tank to the supplied GF Regulator inlet (During this operation make sure that both the tank and the GF Regulator are closed). 2. Connect the GF Regulator output to the Humidifier bottle using TUBE-C. 18

19 Figure 10. UNO-T-H-PREMIXED gas connection How to use the GF Regulator The GF regulator allows to deliver the exact amount of gas flow, in fact since it is provided with a calibrated orifice, it is possible to control the pressure in order to have the desired gas flow. Table 3 shows the relation between Pressure and Flow for the GF Regulator. Pressure [barg] Flow [l/min] 0,2 0,07 0,4 0,10 0,6 0,12 0,8 0,14 1,0 0,17 1,2 0,18 1,4 0,20 1,6 0,22 1,8 0,23 2,0 0,25 2,2 0,27 2,4 0,29 2,6 0,31 2,8 0,32 3,0 0,34 3,2 0,36 3,4 0,38 3,6 0,39 3,8 0,4 Table 3. UNO-T-H-PREMIXED Pressure/Flow relation. Example: the desired gas flow is 0,2, hence the GF Regulator has to be set to 1,4 barg. 19

20 5.3.2 Gas Connection for UNO-T-H-CO2 UNO-T-H-CO2 includes the Air/CO2 mixer and the OKO-AP, it works for application with 100% CO2 and background Air. To make the gas flow into the chamber the steps are the following: 1. Connect your CO2 Gas line/tank to the supplied Pressure Gauge inlet (During this operation make sure that both the tank and the GF Regulator are closed). The CO2 entering the Pressure Gauge has to be set at 2 bar. 2. Connect the Pressure gauge to the CO2 In, which is located on the left of the rear panel of the Air/CO2 Mixer using TUBE-A. 3. Connect the OKO-AP to the Air In, which is located on the right of the rear panel of the Air/CO2 Mixer using TUBE-A. 4. Connect the Air+CO2 OUT, located on the rear panel of the Air/CO2 Mixer, to the Humidifier bottle using TUBE-C. Figure 11. UNO-T-H-CO2 gas connection How to use the Air/CO2 Mixer The Air/CO2 Mixer allows to generate CO2-Air mixtures with an adjustable CO2 concentration in the range 0-15%. Air and CO2 flows are regulated by two floating ball flow meters in the range Nl/min and Nl/min, respectively. As an example, Table 1 reports a set of flow rates to obtain a concentration of CO2 equal to 5%. A more comprehensive table is reported in the manual. Do not use the flow meters as closing-opening valves. Once regulated the CO2 flow pressure (at P= 1bar, see Figure 11), use the flow meters carefully only for fine regulations. 1. Open the gas valves about 15 minutes before inserting the sample in the Micro Environmental Chamber. Please follow carefully scheme in Figure

21 Target Gas Percentage [%] Gas flow rate values to set [Nl/min] Air CO2 Air CO2 Total Table 4. Flow meter regulation, two flow meters control unit. [Nl = Normal litre] 2. Target Gas Percentage indicates the stream gas percentage that the operator wants during the experiment. 3. Gas flow rate values to set, in Normal litre per minute [NL/min], are the values of gas flow rate to set on the graduated scale (see Figure 12). 4. Total indicates the measured total gas stream flow rate. Tip 1. If you need, ask Okolab for personalized Gas Percentage Tables Example: the target Air percentage is 95.00%, the target CO 2 percentage is 5.00%. In Table 4 three possibilities that realize the required gas percentage are. Notice that the values are a compromise between CO 2 consumption, condensation (normally it decreases if Total gas stream flow rate increases) and medium evaporation (normally it decreases if Total gas stream flow rate decreases). We could consider the second line in Table 4. So, we regulate the two flow meters to obtain the desired relative quantity of air and CO 2, as shown in Figure 12. Notice that the correct position of the indicator (ball) is about in its middle. Figure 12. Flow meters graduated scales, example for two gas lines. Note 1. If you use a single reservoir of air+5% CO 2 the total gas steam flow rate suggested is 0.1 L/min. 21

22 Connection of the Temperature Sensor Connect the Temperature Sensor to the real panel, precisely to the green housing on the right, as indicated in Figure 13. Figure 13. Temperature Sensor connection. Tip 1. The Temperature Sensor has to be connected with + on top. 22

23 MINI-USB port The MINI-USB port allows the UNO CONTROL UNIT to be connected with the outside world Connection of a USB drive Use MINI-USB-OTG cable to connect a USB Drive (not supplied) to the CONTROLLER, as shown in Figure 14. Figure 14. USB drive connection PC Connection via USB Use a standard MINI-USB cable to connect UNO CONTROL UNIT to a PC, as shown in Figure 15. You can communicate with UNO CONTROL UNIT via PC by using: DATA-LOG software. The software allows to log and analyze the data provided by UNO CONTROL UNIT via PC. Refer to DATA-LOG user manual for more info. SDK (OKOLAB API) for integration in third party software Figure 15. PC connection via USB. 23

24 RS232 port PC connection via RS232 Use a standard RS232 cable to connect UNO CONTROL UNIT to a PC as shown in Figure 16. This option is advisable when the PC is at a distance greater than 10 meters from the CONTROLLER. You can interface with UNO CONTROL UNIT via PC by using: DATA-LOG software. The software allows to log and analyze the data provided by CONTROLLER via PC. Refer to DATA-LOG user manual for more info. SDK (OKOLAB API) for integration in third party software Figure 16. PC connection via RS232. Without a serial port COM, to install the Serial Communication cable to your PC, you need to install a USB to serial converter following the manufacturer instructions. If you want to log, you have to use the COM port number that Windows assigned to the drive. Installation of the Stage Top Chamber For the installation of the Stage Top Chamber refer to the dedicated attached Stage Top Chamber manual. 24

25 6 USER INTERFACE This chapter describes the user interface of the UNO CONTROL UNIT. Homepage Figure 17 shows the main control panel, in particular it highlights 19 pointers detailed below. Figure 17. Home page. 1. System Information. Press here to know generic info about UNO and its running time. See paragraph Home. Press here to return to the home page. 3. Settings. Press here to access system options and settings. See paragraph Status. Press here to see the status of your system (you will need this page in case of assistance). See paragraph Glance mode. Press here to switch the display to glance mode. See paragraph and UNO status led. See paragraph for the color mapping. 7. Chamber (or T Sensor) current temperature. 8. Temperature set point. 9. Minimum and Maximum temperature values in the actual time window. 10. Temperature at the heating tube. 11. Temperature at the T sensor. 12. Temperature at the lid. 13. Temperature at the base. 14. Temperature at the Objective heater. 15. Support. Press here to learn how to contact OKOLAB. See paragraph Temperature at the Bubbling Column. 17. Open Incubator. 18. PC or USB Connection indicator. 19. Logging icon. 20. Temperature evolution graph. 25

26 6.1.1 Colors meaning The GREEN indicator indicates that the set-point value has been reached (within the tolerance you have set in the alarm subpage, see paragraph 6.3.7) and that the system is working properly. The YELLOW indicator means that the system is working towards reaching the set-points (transient state). No actions on your part are required. Please note the Yellow light will also appear every time you change temperature set point. The ORANGE indicator means that the current temperature is out of the tolerance you have set (see paragraph 6.3.7). Verify that all cables are properly connected. Check all the enclosures to verify that they are properly closed. The RED indicator means that there is a problem with the unit itself (for example the Temperature sensor has been damaged). Turn the system off, wait 5 minutes, and turn it back on. If the problem continues, contact Okolab at Changing the set point temperature To input a new set-point temperature for a heating device, touch the corresponding tab, indicated as Pointer 1 in Figure 18(a). The set point regulation page will appear as in the Figure 18. You can modify the set point by clicking on +/-, see Pointer 2. Once you have input the new set point temperature, press Set to save (or Cancel to undo), see Pointer 3. Tip 2. After any change in the set point value the controller enters into a transient regime, the Status Indicator and the Top LED turn yellow (see paragraph 6.1.1). During the transient regime, the controller will not trigger on alarm. The maximum length of the transient regime is set by the operator as indicated in paragraph (a) Figure 18. Changing the set point temperature Graph view By pressing on the Temperature evolution chart (pointer 1 in Figure 19(a)), the Graph view page will open. By checking or unchecking the checkbox Grid (pointer 2 in Figure 19), it is possible to see or to remove, respectively, the grid behind the graph. 26

27 (a) Figure 19. Graph view. System Information Press the icon related to the Controller version. to access the Info Page, as shown in Figure 20. This page contains the information Figure 20. Info page selection Tip 3. Please have this information handy when contacting Okolab for support. Settings Press on Settings icon to enter the Settings menu, as shown in Figure 21. Figure 21.How to access the Settings page. 27

28 The settings menu has 11 items, as Figure 22(a) and Figure 22 show: 1. Control Mode. See paragraph Alarms. See paragraph Chamber & Insert. See paragraph Obj. Heater. See paragraph Humidity. See paragraph Calibrations. See paragraph Display. See paragraph Password. See paragraph Summary. See paragraph Auto on/off. See paragraph Logging. See paragraph (a) Figure 22. Graph view. Each of the aforementioned item will be detailed in the following Control Mode Press on to enter the Control Mode menu, as Figure 23 shows. Figure 23. Control Mode menu. Once you are in the Control Mode submenu it is possible to choose: 1. Sample Control mode. Figure 24 shows how to select Sample Control mode: Press on the Sample icon; Press Save. 28

29 Now the UNO CONTROL UNIT will start operating in Sample Control Mode. Figure 24. Sample Control mode. Note 1. Sample Control mode allows you to take the temperature feedback from the specimen with the dedicated Temperature Sensor. This mode gives the opportunity to control the environment directly inside the plate with the drawback of having a plate dedicated to the temperature acquisition. 2. Chamber Control mode. Figure 25 shows how to select Chamber Control mode: Press on the Chamber icon; Press Save. Figure 25. Chamber Control mode. Note 2. Chamber Control mode allows you to take the temperature feedback directly from the chamber temperature sensor, without the need of having floating wires for a dedicated specimen s Temperature Sensor. At this point the page Chamber Offset will pop out, see Figure 26. In fact, there are two options for operating in Chamber Control mode: 1. Factory: by pressing on the Factory button the UNO CONTROL UNIT will use the calibration parameters already optimized by Okolab. 2. Calibrate: by pressing on the Calibrate button the UNO CONTROL UNIT will start a routine to calibrate its parameters with the help of the external Temperature Sensor, to be placed inside the chamber before the operation. Figure 27(a) shows the UNO CONTROL UNIT during the calibration procedure; by clicking Options, the menu Advanced calibration parameters will appear and, here, it is possible to set the calibration Accuracy and Precision, see Figure

30 Figure 26. Chamber Control mode Chamber Offset. (a) Figure 27. Chamber Control mode Self Calibration Open Incubator During the normal operation it could be necessary to open the incubator. Figure 28 shows the procedure to follow when opening incubator: 1. Press on Open Incubator, before removing the lid, as Figure 28 (a) shows. Now you can open the incubator; 2. Once you are done close the chamber and wait for 2 minutes in order to let the environment achieve steady state; press on resume operating normally. Incubator Closed, as Figure 28 shows, and the UNO CONTROL UNIT will (a) Figure 28. Control mode Open Incubator. 30

31 Opening the incubator can lead to controller instability since both the specimen and the inside of the chamber are exposed to the external environment. In order to avoid the problem, UNO CONTROL UNIT has to stay in a holding state until the incubator is closed and its environment is in a steady state. This can be achieved using the Open Incubator procedure Chamber & Insert UNO CONTROL UNIT is available for a plethora of chambers to perfectly fit your specific microscope setup and the plates you need to use. Since the bottom of the chamber is in contact with the external environment, the UNO CONTROL UNIT has to modify its controlling parameters in dependence of the specific couple Chamber/Insert. To setup your Chamber/Insert configuration press on Chamber & Insert, as Figure 29(a) shows. At this point the Chamber & Insert submenu in Figure 29 will appear. (a) Figure 29. Chamber & Insert. Figure 30(a) and show the selection menus for Chamber and Insert, respectively. You can navigate through the menus to choose the objects present in your UNO CONTROL UNIT configuration. (a) Figure 30. Chamber & Insert configuration. (a)chamber selection; Insert selection. 31

32 Compatible chambers Table 5 reports all the available chambers for UNO STAGE TOP INCUBATOR. Chambers: H301-K-FRAME H301-NIKON-TI-S-ER H301-OLYMPUS-IX3-SVR H301-PRIOR-H117 Detail: Fits standard XY stages with k-frame insert (160x110mm). Chambers: H301-LUDL96A602 H301-MCL-Z100/500 H301-NIKON-NZ100/200/500-N H301-PI x110 Detail: Fits Z-piezo stages models listed. Chambers: H301-MINI Detail: Fits in any MW plate holder. Chambers: H301-NIKON-TI-SR H301-OLYMPUS-IX-SUSP Detail: Fits rectangular stages with circular opening. Chambers: H301-EC-LG-BL Detail: Fits Leica Super Z Galvo Stage (SP5/SP8). Chambers: H301-PRIOR-NZ500 Detail: Fits Prior Z-piezo stages models NZ250/400/

33 Chambers: H301-PRIOR-NZ100-H107 H301-PRIOR-NZ100-H117 H301-PI-736-ZR15/ZR25 Detail: Fits Prior Z-piezo stages models listed. Chambers: H301-UP Detail: Fits any Upright Microscopes. It allows the usage of dipping lenses. Chambers: H301-EC-LG-UP-BL Detail: Fits Upright Leica Super Z Galvo Stage. It allows the usage of dipping lenses. Chambers: H301-DUAL-GAS Detail: Chamber with two independent gas compartments. Chambers: CUSTOM Detail: Parameters for custom chambers. Table 5. Compatible chambers. 33

34 6.3.3 Objective Heater Press on Objective Heater icon to enter the Objective Heater menu, see Figure 31(a). The Objective Heater is disabled by default, to activate it press on the Enabled icon, see Figure 31. At this point you can choose: 1. Ramp Rate. By pressing on this button the submenu in Figure 32 will appear; here you can tune the ramp rate for the temperature of the Objective Heater. 2. Cancel. To Cancel your choice. 3. OK. To confirm your choice; moreover, after pressing this button, the menu in Figure 33 will appear giving you further options. (a) Figure 31. Objective Heater. (a) How to access the Objective Heater menu; Objective Heater menu. Figure 32. Ramp rate. Before enabling the Objective Heater, make sure that it is correctly mounted around your objective and that it is connected to the UNO CONTROL UNIT. Figure 33 shows the menu that appears when selecting the Objective Heater feature, with reference to the Pointers 4 options are available: 1. Log: by pressing this button you can recall parameters obtained with previously performed calibrations, see Figure 34(a); 2. Factory: by pressing this button UNO CONTROL UNIT will resume the factory offset; 3. Manual: by pressing this button can find the best offset value manually, step by step, see Figure 34; 4. Calibrate: by pressing this button UNO CONTROL UNIT will perform a calibration routine for your specific environment, see paragraph

35 Figure 33. Objective Heater Enabled. (a) Figure 34. Objective Heater options. (a) Log; Manual Humidity Press on Humidity icon to enter the Humidity menu, see Figure 35. Figure 35. How to access the Humidity menu. Figure 36(a) shows the Humidity menu. Once the Humidity control enabled checkbox is checked, UNO CONTROL UNIT will perform humidity control acting on the temperatures of both the humidifier s bottle and the heated tube. In order to make the humidity control work properly, the user has to set the actual room temperature, see Figure 36(a). UNO CONTROL UNIT, by default, supplies a humidity level of 90%; whereas when you require a different humidity level, it is possible to act on the Offset temperature, see Figure 36: rising this value will lead to rising the humidity level as well. 35

36 (a) Figure 36. Humidity menu. (a) Main menu; Offset Calibration Press on Calibration icon to enter the Settings menu, as shown in Figure 37. Figure 37. How to access Calibration menu. Once you are in the Control Mode submenu it is possible to choose: 1. Chamber Calib. Here you can perform the calibration of the chamber, see paragraph T Sensor. Here you can perform the calibration of the Temperature Sensor, see paragraph Obj calibration. Here you can perform the calibration of the Objective Heater, see paragraph Chamber Calibration Press on Chamber Calib icon 39., as Figure 38 shows, to enter the Chamber Calibration submenu in Figure Figure 38. Chamber calibration. 36

37 Two options are available to the Chamber Calibration, see Figure 39: 1. Factory: by pressing on the Factory button the UNO CONTROL UNIT will use the calibration parameters already optimized by Okolab. 2. Calibrate: by pressing on the Calibrate button the UNO CONTROL UNIT will start a routine to calibrate its parameters with the help of the external Temperature Sensor, to be placed inside the chamber before the operation. Figure 40(a) shows the UNO CONTROL UNIT during the calibration procedure; by clicking Options, the menu Advanced calibration parameters will appear and, here, it is possible to set the calibration Accuracy and Precision, see Figure 40. Figure 39. Chamber Control mode Chamber Offset. (a) Figure 40. Chamber Control mode Self Calibration T sensor Calibration The Temperature Sensor of UNO CONTROL UNIT is calibrated in Okolab at three different temperatures, i.e. 35.0, 37.0 and 40.0 C. To view the factory calibration data, press on the T sensor calibration icon as shown in Figure 41(a) and then on the tab labeled Factory as shown in Figure 41; the page with the calibration data will open, as shown in Figure

38 (a) Figure 41. Calibration data. (a) T sensor calibration page selection; T sensor calibration page. Figure 42. Free sensor factory offset To re-calibrate the T sensor, follow the instructions below. 1. Set a water bath to the temperature you use as set point for the heating devices during standard operation (most of the times it is 37 C); 2. Measure water temperature by immersing the Temperature Sensor and a Certified Thermometer; 3. Type in the reading of the certified thermometer by pressing on the pencil, as shown in Figure 43(a); 4. Press on Set to adjust to reading of the Temperature Sensor against the reading of the certified thermometer, as shown in Figure 43. (a) Figure 43. How to re-calibrate the T sensor Tip 4. Press on icon to receive instructions on how to calibrate the T-Sensor. Tip 5. Okolab recommends using a certified thermometer as external reference. 38

39 Objective Heater Calibration Press on Obj calibration icon, as Figure 38 shows, to enter the Objective Heater Calibration. Figure 44. Objective Heater calibration. To perform the calibration, refer to the following steps: 1. Stick the Temperature Sensor (green wire) at the bottom of the dish under observation; 2. Fill the dish with distilled water until the Temperature Sensor is completely immersed in water; 3. Close both this dish and the incubating chamber with their own respective lids; 4. Touch the CALIBRATE button (pointer 4 in Figure 33); 5. The warning dialog in Figure 45(a) will appear, after double checking the previous steps, click OK and the calibration will start as Figure 45 shows. Note 1. To calibrate the Objective Heater be sure that Chamber calibration has already been performed. (a) Figure 45. Objective Heater calibration. Figure 46 shows the Advanced calibration parameters for the procedure, that are accessible by pressing on Options during the calibration procedure. Figure 46. Objective Heater calibration. Advanced calibration parameters. 39

40 6.3.6 Logging UNO CONTROL UNIT is equipped with local memory to store the temperature and calibration data on its internal memory. These data can be then downloaded on a USB stick at user request. In order to activate the logging, follow the steps indicated below: 1. Press on Logging icon and flag Internal memory in the page that appears, see Figure 47. Tip 6. When activating the logging on the internal memory, you can access the Logging page also by pressing the activated logging icon on the Homepage, as shown in Figure 48. (a) Figure 47. Logging. (a) How to enter in the logging menu; logging in internal memory Figure 48. How to access the Logging page from the Homepage 2. Press on the icon to insert the logging time, see Figure 49. You can change this time in the range 1-60 seconds. (a) Figure 49. How to set the logging time 40

41 3. Choose how you want to split the data when downloaded, by pressing on Day, Week or Month, see Figure 49 (a). Tip 7. If you select Day, the data will be split in files, each one containing the data on one day. If you select Week, the data will be split in files, each one containing the data on one week. 4. Write the file name suffix to be reported in the downloaded files by pressing on the keyboard icon, see Figure 50(a). Then press on Save, see Figure 50. Tip 8. With the selections done in Figure 49 and in Figure 50, the data will be downloaded in the USB drive as shown in Figure 51. (a) Figure 50. Data Logging. How to define the suffix for the downloaded files Figure 51. Downloaded files on the pen drive Note 3. If you press on the screwdriver, see Figure 52(a) you can view the logging starting date, the available memory and the latest download, see Figure 52. Note 4. The available memory depends on the time interval you have inserted in the Logging page. The default logging time is 30 seconds. (a) Figure 52. Internal memory status. (a) Logging page settings; Internal log page settings To download the data, press on To USB or on Erase if you want to delete them, see Figure

42 (a) Figure 53. Download to USB You can activate the logging also on the USB stick, by flagging on USB pen drive, see Figure 54(a). (a) Figure 54. Logging on USB drive. (a) USB drive selection; Reminder to connect the USB drive In this case, UNO advices you that a pen drive must be connected to the USB port, see Figure 54, and will store the data on the USB drive Alarms When UNO CONTROL UNIT triggers on alarm, it may activate both visual and audible alarms. To set the alarms specifications, press on the Alarms icon below: ; see Figure 55(a) then follow the indications 1. Insert the alarm time; i.e. the time for which the temperature of the Heating Devices may remain outside the allowed tolerance before the controller triggers in alarm, see 1 in Figure 55 Note 5. The alarm time range is 5-20 minutes. 2. Insert the Tolerance value, see 2 in Figure 55. This value defines the allowed tolerance form the set point. Note 6. The tolerance value range is C 3. Insert the transient time; i.e. the maximum time that the system can take to reach a new set point, without triggering the alarm, see 3 in Figure

43 (a) Figure 55. Alarms settings. (a) How to enter the Alarm setting menu; Alarm configuration Note 7. Tip 9. The transient time range is minutes. After any change in the set point value the device enters into a transient regime. 4. Flag the tab labeled Buzzer if you want the alarm to be acoustical, additionally to being visual, see Figure Flag the tab labeled Enabled to enable the Alarms logic, see Figure To disable the visual and acoustical alarms, remove the flag from the tab labeled Enabled. In this case the Alarms page becomes as shown in Figure 56. Figure 56. Alarms page when the alarms are disabled Tip 10. When disabling the alarms, the CONTROLLER goes into alarm condition only when the status LED becomes red (for example is a device is accidentally disconnected) Note 8. By Pressing on Log (see Figure 57(a)), you can view all the times that the status LED of the two devices have changed color (see Figure 57). (a) Figure 57. Logging alarms page 43

44 Press on To USB if you want to download the alarms data to a USB drive or on Erase if you want to delete them Display To enter in the Display configuration menu, press on the icon page shown in Figure 58 will appear. 1. Options. See paragraph Brightness. See paragraph Calibration. See paragraph Date & Time. See paragraph Visual Effects. See paragraph Factory Reset. See paragraph , as shown in Figure 58(a) and the Display (a) Figure 58. Display settings page. (a) How to enter the Display menu. Display menu Options The Display Options menu allows t set the time frame in which the minimum and maximum temperature values are collected. To insert the time frame, press on the icon Displayed time frame bar or click the +/- icons, then press Save, see Figure 59. and slide your finger along the (a) Figure 59. Options subpage configuration. (a) Select options; Setting display options 44

45 Note 9. The max and minimum temperature value will be displayed in the top left box in the Homepage (see pointer 9 in Figure 17). To change the touch sound frequency press and slide your finger along the setting bar indicated with Sound frequency, then press Save, see Figure 59 Note 10. To activate a sound at each touch, flag the tab labeled Touch Sound Brightness To modify display Brightness press the icon and scroll the bar or press the +/- icons in the page that opens, as shown in Figure 60. (a) Figure 60. Brightness display page Set the required configuration and then press on Save to obtain the right configuration of Brightness, see Figure Calibration When pressing the calibration icon, the procedure for the calibration of the touch screen will start. Figure 61. Touch screen calibration. Note 11. If the touch screen is not calibrated and it is not possible to navigate in the menu, then press and hold the power button for more than 10 seconds and the touch calibration will start Date & Time To set Date & Time, follow the instructions below: 1. Press the Date & Time icon, see Figure 62(a) 45

46 2. Set the values, as shown in Figure Click on Save to save or Cancel to undo (a) Figure 62. Select Date&Time configuration. Tip 11. Flag the 24 hours box, if you want to use the hour format based on 24 hours Visual Effects To enter in the Display visual effects menu, press on the icon, see Figure 63 (a). (a) Figure 63. Display Visual Effects. (a) How to enter in Visual Effects menu; Visual Effects menu. The Top LED settings allows you to when the Top LED should be illuminated: if you select Never, the Top LED will never illuminate, if you select On Alarm, the Top LED will illuminate only when the Controller is in Alarm Status (see paragraph 6.1.1), if you select Always, the Top LED will always illuminate. Glance Mode Setting (see also paragraph 6.5) The Glance mode setting defines the color of the Top LED and of the digits displayed in Glance Mode. If you select White, the Top LED illuminates in white color (according to the criterion selected in Top LED setting) and the digits displayed in Glance Mode are white. If you select Dynamic the color of the Top LED and the color of the digits in Glance Mode follow the color coding reported in paragraph Tip 12. To swap between Icon and Glance mode press on the icon Factory Reset To reset the display settings, press on the icon, see Figure 64(a). At this point Figure 64 will appear, asking to confirm the Factory Reset of the display. 46

47 (a) Figure 64. Factory reset Password With the UNO CONTROL UNIT, as well as with many Okolab s products, the user have the chance to secure his laboratory setups by using a password. The password, when enabled, will be asked, in the following procedures: Heating devices calibration procedures T sensor calibration Data download Data erase To enable the password protection, follow the steps below: 1. Press on the Password icon, see Figure 65(a) 2. Flag the tab Password enabled as shown in Figure 65 (a) Figure 65. Password. (a) Password settings menu; password subpage Note 12. The default password is okolab, and it is disabled. Okolab recommends changing this password. Note 13. If you forgot the password, use the restore password reported on the certificate attached to UNO CONTROL UNIT. 3. To change the password, press on the icon and follow the indications that will appear. 47

48 Summary The Summary Page reports technical information. To enter the Summary menu, press on the settings icon appear., as shown in Figure 66(a), then press on Summary icon. The page reported in Figure 66 will Note 14. This page is useful essentially for technical/control reasons. During a support case the engineers of Okolab s team may ask you to read some of the data reported in Summary page (a) Figure 66. Auto on/off. (a) Auto on/off menu; Auto on/off subpage Auto on/off Press on to enter the Auto on/off menu, see Figure 67(a). Once you are in the Auto on/off menu, you can choose between, see Figure 67: Auto turn on: to schedule the automatic turn on of UNO CONTROL UNIT; Auto turn on: to schedule the automatic turn on of UNO CONTROL UNIT. (a) Figure 67. Auto on/off. (a) Auto on/off menu; Auto on/off subpage. We will now describe the available options for the Auto turn on procedure only, but the description perfectly fits also to the Auto turn off procedure, whose point to point description has been omitted for the sake of simplicity. 48

49 Figure 68(a) shows how to access the Auto turn on subpage. As Figure 68 depicts, by default the Auto turn on/off is disabled. (a) Figure 68. Auto on/off options. It is possible to set a time when UNO CONTROL UNIT has to start Every day by pressing on its tab, or it is possible to select the specific days in the week by choosing Specific days, see Figure 69(a). Pressing Save will make your choice effective. (a) Figure 69. Auto on/off on specific days. Status On this page you can read the Status of CO2-O2-CONTROLLER; this is useful to check that the system is working properly. Most of the parameters displayed are technical/control parameters that you may be asked to access in case you have requested for Okolab support. (a) Figure 70. Status page. 49

50 Glance Mode Pressing on Glance Mode (see Figure 71(a)), you can change the data visualization format on the Homepage that turns into a brief information about the state of the atmosphere inside the incubator, as Figure 71 shows. (a) Figure 71. Glance Mode view. This visualization type allows you to have a quick overview of the device from far away. See paragraph for Glance Mode settings. 50

51 7 MAINTENANCE To get a correct Gas controller operation over time: Use a polishing cloth or dry cloth to wipe off dust and dirt. Never use thinners, benzene, solvents on or near the devices, since these could corrode the surfaces. Verify the status of all hoses/tubing and replace those damaged. After 2 years, disconnect all polyurethane tubing, cut the last 1 cm of the tubing and reconnect them to the connectors. Before cleaning the unit, make sure it is unplugged form the power source. Water must not enter the system. 51

52 8 SUPPORT Support page The support page can be reached pressing on the question mark in Homepage (see Figure 72(a)), the page in Figure 72 will open. Here you can see the Italian and American Okolab contacts, moreover you can use the QR code to get to the Okolab site. (a) Figure 72. Support page. In order to send directly an to the Okolab staff, you can use the QR codes shown in the following images: For commercial info: For technical info: Figure 73. QR code for commercial info contact. Figure 74.QR code for technical info contact. 52

53 Support Contacts Please, do not hesitate to contact Okolab if you need any further commercial information or technical support. Please, check Okolab web site for news, events, new products and general FAQs. For COMMERCIAL SUPPORT: Phone Fax: Mobile: For TECHNICAL SUPPORT: Phone Mobile: Okolab S.r.l. Via A. Olivetti, Pozzuoli, NA Italy Web Conference For Assistance And Training In case you requested on line support and/or web conference assistance for system assembling and experiment support, you received a web cam. Please follow these guidelines to receive optimum service. Webcam installation (instruction and Cdrom included) Latest Skype software installed ( Register yourself on to have an account (Skype_ID) Set the audio and video and test them using Skype. Contact our technical support (sibillo@oko-lab.com) by to take an appointment for the web assistance. 53

54 9 TECHNICAL SPECIFICATIONS UNO CONTROL UNIT Technical Specifications Operating Temperature +3 C above ambient ~.+60 C Storage Temperature -5 C ~ +60 C Operating Humidity 90% Power Consumption 24V- 5A, 120 W max Weight 0,4 Kg 54

H301-T-UNIT-BL-PLUS Electric Top Stage Incubation System Manual

H301-T-UNIT-BL-PLUS Electric Top Stage Incubation System Manual H301-T-UNIT-BL-PLUS Electric Top Stage Incubation System Manual Vers. 02.14 1 This page was left blank 2 Index Index 1 REVISION TABLE... 4 2 PREFACE... 5 3 SYMBOLS DESCRIPTIONS... 5 3.1.1 Symbols in this

More information

Bold Line Top Stage Incubator

Bold Line Top Stage Incubator H301 T UNIT BL H301 T UNIT BL Bold Line Top Stage Incubator Temperature, Humidity, CO 2 /O 2 Control, Touch Screen and Web server The systems comprises: Incubating chamber (model avaialble for any XY stage

More information

DGT-CO2BX, Digital CO 2 Controller. Manual

DGT-CO2BX, Digital CO 2 Controller. Manual DGT-CO2BX, Digital CO 2 Controller Manual Ver.02/2008 1 Preface DGT-CO2BX is a Digital Control Unit that generates a CO 2 -Air mixture with an adjustable CO 2 concentration in the range 0-20%, with an

More information

UNO-COMBINED-CONTROLLER. CO 2 Microscope Electric Top Stage Incubation System. Manual. Vers

UNO-COMBINED-CONTROLLER. CO 2 Microscope Electric Top Stage Incubation System. Manual. Vers UNO-COMBINED-CONTROLLER CO 2 Microscope Electric Top Stage Incubation System Manual Vers. 02.14 1 This page was left blank 2 Index Index 1 REVISION TABLE... 5 2 PREFACE... 6 3 SYMBOLS DESCRIPTIONS... 7

More information

Single UNO. Incubator. .com. Main Features: Incubating chamber. of a Multi Well plate. Manual Air/CO 2 mixer. operation.

Single UNO. Incubator. .com. Main Features: Incubating chamber. of a Multi Well plate. Manual Air/CO 2 mixer. operation. UNO Incubator All-in-one temperature/humidity/co2 incubator Top Stage Incubator with the footprint of a Multi Well plate Fits in any XY stage, with the addition of the Multi Well plate holder (supplied

More information

Bold Line Cage Incubator

Bold Line Cage Incubator Bold Line Cage Incubator com Bold Line Cage Incubator Bold Line Cage Incubator Large volume incubator with local CO 2 /O 2 climate chamber The systems comprises: Microscope enclosure Obscuring panels (optional)

More information

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments Pegas 4000 MF Gas Mixer InstructionManual Contents I Table of Contents Foreword Part I Introduction 1 2 1 System overview... 2 2 Specifications... 3 Part II Installation 4 1 Rear panel connections...

More information

User Manual November 2014

User Manual November 2014 H301-EC-LG-UP-BL Compatible with the following Z-Piezo stages Compatible with the following Okolab Controllers LEIC Super Z Galvo stage (SP5/SP8) H301-T-BL-PLUS UNO-COMBINED-CONTROLLER H401-T-DUL Page1

More information

Armfield Distillation Column Operation Guidelines

Armfield Distillation Column Operation Guidelines Armfield Distillation Column Operation Guidelines 11-2016 R.Cox Safety SAFETY GLASSES ARE REQUIRED WHEN OPERATING THE DISTILLATION COLUMN Wear gloves when mixing alcohol feedstock The column will become

More information

User Manual. Quantos Automated Dosing Liquid Module

User Manual. Quantos Automated Dosing Liquid Module User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if

More information

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

A180 DO/BOD/OUR/SOUR Meter Instruction Manual A180 DO/BOD/OUR/SOUR Meter Instruction Manual BANTE INSTRUMENTS CO., LTD A180 DO/BOD/OUR/SOUR Meter 1 Introduction Thank you for selecting the A180 multiparameter dissolved oxygen meter. This manual provides

More information

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300 Technical Note GA-300 Overview The GA-300 CO2 and O2 Gas Analyzer is easy to use, robust, and adaptable to human, animal, and plant applications. The GA-300 has two analog outputs to allow recording and

More information

In Vivo Scientific, LLC INSTRUCTION MANUAL

In Vivo Scientific, LLC INSTRUCTION MANUAL CO 2 Controller In Vivo Scientific, LLC INSTRUCTION MANUAL CONTENTS CONTENTS...1 ABOUT THIS MANUAL...2 INTRODUCTION...2 Cautions and Warnings...2 Parts List...2 Unpacking...2 INSTRUMENT DESCRIPTION...3

More information

Overview. Front Panel: Keypad and Display

Overview. Front Panel: Keypad and Display Overview The GA-200B is an analyzer that integrates a gas sampling system with sensors to measure and display the concentrations of oxygen and carbon dioxide in a sample as the percentage of a gas in the

More information

RM-80 respiration monitor

RM-80 respiration monitor RM-80 respiration monitor User Manual September 18, 2015 0025-003M 950 North Hague Avenue Columbus, Ohio 43204-2121 USA Sales: sales@colinst.com Service: service@colinst.com Phone: (614) 276-0861 Fax:

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Bante821 Portable Dissolved Oxygen Meter Instruction Manual Bante821 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante821 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante821 portable dissolved oxygen

More information

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER) Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER) Background There are two main sources of energy available for animal metabolism: carbohydrates (CHO) and fats. These molecules are broken

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante810 Benchtop Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante810 benchtop dissolved oxygen

More information

NEULOG OXYGEN LOGGER SENSOR GUIDE

NEULOG OXYGEN LOGGER SENSOR GUIDE NeuLog oxygen logger sensor NUL-205 The oxygen sensor can be used for any science experiment or activity where oxygen levels, dissolved or gaseous, are required. Some fields of study include Chemistry,

More information

TR Electronic Pressure Regulator. User s Manual

TR Electronic Pressure Regulator. User s Manual TR Electronic Pressure Regulator Page 2 of 13 Table of Contents Warnings, Cautions & Notices... 3 Factory Default Setting... 4 Quick Start Procedure... 5 Configuration Tab... 8 Setup Tab... 9 Internal

More information

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER) Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER) Background There are two main sources of energy available for animal metabolism: carbohydrates (CHO) and fats. These molecules are broken

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1 HPICAL-15000 Operation & Data Logging Procedures Click spacebar to advance through slides 1 WARNING Always wear proper safety equipment when using high pressure equipment. Do not exceed 125 psi air pressure.

More information

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual Bante820 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante820 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante820 portable dissolved oxygen

More information

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1 BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1 The front door of the main body of the instrument may be open when you arrive. Take the sample chamber and slide it into position with the

More information

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES 450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES PART NO. 45053 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing

More information

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS 2000 Dionex Corporation Document No. 031277 Revision 03 April 2000 2000 Dionex Corporation All rights reserved worldwide. Printed in the United States of

More information

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems Corporation Issued: 5/09 P/N: 600104 Rev. 2 Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems The Gas Addition Accessory permits the

More information

Digital Vacuum Regulator

Digital Vacuum Regulator Temperature Control for Research and Industry Digital Vacuum Regulator User s Manual Model 300 INDEX SECTION PAGE 1. QUICK OPERATING INSTRUCTIONS........................... 3 Safety Notices.................................................

More information

Operator Quick Guide ORBISPHERE 3654

Operator Quick Guide ORBISPHERE 3654 Operator Quick Guide ORBISPHERE 3654 Revision H - 14/03/2008 Operating Information About this Guide The information in this guide has been carefully checked and is believed to be accurate. However, Hach

More information

MoveRoll Conveyor Operating and Maintenance Manual

MoveRoll Conveyor Operating and Maintenance Manual MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.

More information

ETT Olfactometer: Getting started guide 2013a. ETT Olfactometer quick start

ETT Olfactometer: Getting started guide 2013a. ETT Olfactometer quick start ETT Olfactometer quick start Table of Contents Safety Information... 3 Contact to ETT... 3 Un-boxing / Installation... 3 Resources overview... 7 Working with the ETT Olfactometer... 8 Creating the first

More information

PERFORM Operating Document

PERFORM Operating Document PERFORM Operating Document Use and Maintenance of CO 2 Incubator PC-POD-CA-007-v03 Revision History Version Reason for Revision Date 01 New POD 30-Sep-13 02 Minor revisions for section 2.3, 3.1, 4.3. 14-April-16

More information

Heavy Duty Dissolved Oxygen Meter

Heavy Duty Dissolved Oxygen Meter User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com Introduction Congratulations

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0578 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

Series Environmental Chambers

Series Environmental Chambers 3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable

More information

PERFORM Operating Document

PERFORM Operating Document PERFORM Operating Document Use and Maintenance of CO 2 Incubator PC-POD-CA-007-v02 Revision History Version Reason for Revision Date 01 New POD 30-Sep-13 02 Minor revisions for section 2.3, 3.1, 4.3. 14-April-16

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0545 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

MASSACHUSETTS STATE POLICE CRIME LABORATORY. Certificate of Calibration Procedure for the Alcotest 9510

MASSACHUSETTS STATE POLICE CRIME LABORATORY. Certificate of Calibration Procedure for the Alcotest 9510 MASSACHUSETTS STATE POLICE CRIME LABORATORY Certificate of Calibration Procedure for the Alcotest 9510 Effective Date: May 10, 2017 Page 1 of 23 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 ABBREVIATIONS...

More information

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT 200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

User Manual. Quantos Automated Dosing Powder Module

User Manual. Quantos Automated Dosing Powder Module User Manual Powder Module 1 Introduction Thank you for purchasing the Quantos dosing system. Quantos is based on the renowned and reliable XPE series balances from METTLER TOLEDO. Besides the highly accurate

More information

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer July 2011 OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer WARNING! Before operating this product, read and understand this Operator s Manual. Become familiar with the potential hazards of this unit. Contact

More information

BI-680 Online Dissolved Oxygen Controller Instruction Manual

BI-680 Online Dissolved Oxygen Controller Instruction Manual BI-680 Online Dissolved Oxygen Controller Instruction Manual BANTE INSTRUMENTS CO., LTD BI-680 Online Dissolved Oxygen Controller 1 Introduction Thank you for selecting the BI-680 online dissolved oxygen

More information

MP15 Jockey Pump Controller

MP15 Jockey Pump Controller Setup and Operating Instructions MP15 Jockey Pump Controller This manual provides general information, installation, operation, maintenance, and system setup information for Metron Model MP15 Jockey Pump

More information

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

AIR/OXYGEN BLENDER INSTRUCTION MANUAL BIO-MED DEVICES AIR/OXYGEN BLENDER INSTRUCTION MANUAL CATALOG #2120 REV 042203 BIO-MED DEVICES INC. 1445 BOSTON POST ROAD, GUILFORD, CT 06437 (203) 458-0202 FAX (203) 458-0440 www.biomeddevices.com TABLE

More information

User s Guide. Pressure Controller for liquid delivery systems

User s Guide. Pressure Controller for liquid delivery systems Flow Control User s Guide Pressure Controller for liquid delivery systems Precise Pressure Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery

More information

Instruction Manual. BZ7002 Calibration Software BE

Instruction Manual. BZ7002 Calibration Software BE Instruction Manual BZ7002 Calibration Software BE6034-12 Index _ Index Index... 2 Chapter 1 BZ7002 Calibration Software... 4 1. Introduction... 5 Chapter 2 Installation of the BZ7002... 6 2. Installation

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual ORB-400 BUBBLE/HAZE MACHINE Item ref: 160.462UK User Manual Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty Introduction Thank you for

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

Laboratory Mortar Mixer (Testing)

Laboratory Mortar Mixer (Testing) TomTom-Tools GmbH Zelgli 20 8905 Arni info@tomtom-tools.com Switzerland www.tomtom-tools.com User Manual Version February 22, 2015 Laboratory Mortar Mixer (Testing) 1 Introduction The Laboratory Mortar

More information

BGA244 Binary Gas Analyzer

BGA244 Binary Gas Analyzer Quick Start Guide Revision 1.0 Certification Warranty Service certifies that this product met its published specification at the time of shipment. This product is warranted against defects in materials

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4

More information

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR MODEL NUMBER: 45043-450P-A AUTOMATIC PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and

More information

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel TANK MANAGER FOR TWO TANKS OPERATING MANUAL 10/31/11 C-More T6C L color touch panel 1 TABLE OF CONTENTS GENERAL...3 INSTALLATION...4 STONE TEST PROCEDURE...7 OPERATIONAL SUMMARY...7 AUTO CARBONATION...10

More information

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS

More information

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions) Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions) 1. Uncrate blender from packaging. 2. Lift the blender and position over machine throat or floor

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

Quick Installation Guide Doc nr.: C Date:

Quick Installation Guide Doc nr.: C Date: Quick Installation Guide Doc nr.: 9.17.093C Date: 13-05-2016 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or

More information

UsER manual for Watersens ph -REDOX

UsER manual for Watersens ph -REDOX UsER manual for Watersens -REDOX Cl 8 1 2 6 3 3 7 7 4 4 4 4 Parts List 1 Redox Probe 1 x 2 PH Probe 1 x 5 Tube Weight 2 x 6 Connection Valve 1 x chlorine 3 Chlorine and Pumps 2 x 7 Dosing Valve 2 x 5 5

More information

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

MCQ Gas Blender 100 Series 3 Channels Gas Mixer Channels Gas Mixer Revision 1.8 October 2016 High Performance Digital Gas flow Gas Dilutor Blender & Gas for Mixing flow Mixing Gases System and Calibration Routines Technical Data Sheet Lab in a box From

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

SC505 Sof Care Inflator. Operating Instructions and Service Manual

SC505 Sof Care Inflator. Operating Instructions and Service Manual SC505 Sof Care Inflator Gaymar Industries, Inc. 10 Centre Drive Orchard Park, NY 14127 Toll Free +1 800.828.7341 + 1 716.662.2551 Fax +1 800.993.7890 Outside USA +1 716.662.8636 Outside USA Fax +1 716.662.0730

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

Digital Melting Point Apparatus

Digital Melting Point Apparatus Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1 Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature

More information

Instruction Manual Dräger MSI P7 and MSI P7 plus

Instruction Manual Dräger MSI P7 and MSI P7 plus Dräger MSI GmbH Rohrstraße 32 58093 Hagen Tel.: +49-2331 / 9584-0 Fax: +49-2331 / 9584-29 e-mail: info@draeger-msi.de D 923; Edition 2011-01-01 Content 1. General Hints Page 4 2. The Instrument 2.1 Front

More information

PitchTracker Softball User Guide

PitchTracker Softball User Guide PitchTracker Softball User Guide Model: DKPTS01 User Guide PACKAGE CONTENTS What Comes in the Box USING YOUR SMART SOFTBALL Turn On Your Smart Softball Pair your Smart Softball Turn Off Your Smart Softball

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

Variable Temperature Operation

Variable Temperature Operation Variable Temperature Operation AVIII 400 MHz Spectrometer November 11, 2012 The CBC NMR Laboratory University of Delaware AVIII 400 User Guide: Variable Temperature Operation 1 INTRODUCTION... 5 1.1 SAFETY...

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

5890II GC Standard Operating Procedure 9/2/2005

5890II GC Standard Operating Procedure 9/2/2005 5890II GC Standard Operating Procedure 9/2/2005 This procedure is for the analysis of natural gas using the HP 5890II GC with the Restek ShinCarbon column. Detector Type: TCD Column Type: Restek Micropacked,

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

User s Guide. CO2 Controller for miniature incubators

User s Guide. CO2 Controller for miniature incubators CO2 Control User s Guide CO2 Controller for miniature incubators Precise CO2 Control throughout the experiment Media ph control Compatible with any perfusion system Miniature incubators for any microscope

More information

RAM Operation Manual

RAM Operation Manual RAM 4021-1 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-1 For Your Safety... 2 Description... 2 Setup Mode... 3 Lights/Alarms... 3 Operation... 4 Calibration...

More information

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties Quick Installation Guide Doc nr.: 9.17.052H Date: 10-12-2015 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or

More information

Instruction Manual ibidi Gas Incubation System

Instruction Manual ibidi Gas Incubation System Instruction Manual ibidi Gas Incubation System Version 2.0 11920 ibidi Gas Incubation System for CO2 11922 ibidi Gas Incubation System for CO2 and O2 www.ibidi.com Contact ibidi GmbH Am Klopferspitz 19

More information

with O 2 Controller Instruction Manual

with O 2 Controller Instruction Manual 14500 Coy Drive, Grass Lake, Michigan 49240 734-475-2200 E-mail: sales@coylab.com www.coylab.com Hypoxic Cabinets (In-Vivo / In-Vitro) with O 2 Controller Instruction Manual Index Page Warranty 2 Warnings

More information

PitchTracker User Guide. Model: DKPT01 User Guide

PitchTracker User Guide. Model: DKPT01 User Guide PitchTracker User Guide Model: DKPT01 User Guide PACKAGE CONTENTS What Comes in the Box USING YOUR SMART BALL Turn On Your Smart Ball Pair your Smart Ball Turn Off Your Smart Ball Charge your Smart Ball

More information

Installation Procedure Esco Miri Multi-Room Incubator

Installation Procedure Esco Miri Multi-Room Incubator Esco Miri Multi-Room Incubator Version 1.1 ESCO MEDICAL Esco Micro Pte Ltd 21 Changi South Street 1 Singapore 486777 Tel. : +65 6542 0833 Fax : +65 6542 5732 / 6546 2913 Mail : csis-medical@escoglobal.com

More information

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17 Operation Manual Pro He Alarm TM Helium Analyzer Rev 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

K-SYSTEMS. CO2 / O2 Long Term Incubator G185. User Manual. Version 1.6

K-SYSTEMS. CO2 / O2 Long Term Incubator G185. User Manual. Version 1.6 K-SYSTEMS User Manual CO2 / O2 Long Term Incubator G185 Version 1.6 Table of contents 1 General Information & Service...5 2 Explanation of Symbols Used in Manual...6 3 Safety symbols...7 4 Precautions/warnings...10

More information

RAM 4021-DPX Operation Manual

RAM 4021-DPX Operation Manual RAM 4021-DPX Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS ABL 4021-DPX / RAM 4021-DPX For Your Safety... 3 Description... 3 Setup Mode... 4 Lights/Alarms... 4 Operation...

More information

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS U S E R M A N U A L Model: PM4300 Series (PM4351 Shown) SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090

More information

Instruction Manual. Biogas Analyzer InCa Bio 04

Instruction Manual. Biogas Analyzer InCa Bio 04 Instruction Manual Biogas Analyzer InCa Bio 04 Instruction Manual InCa Bio 04 contents - IMPORTANT - Refer to the safety intructions before installation begins 2 Manual InCa Bio 04 07-10-10 R2 Table of

More information

The Univentor 1250 Anaesthesia Unit

The Univentor 1250 Anaesthesia Unit THE UNIVENTOR 1200/1250 ANAESTHESIA UNIT The Univentor 1250 Anaesthesia Unit TABLE OF CONTENTS EDITION 1 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2

More information

User Manual MFCS TM -EZ

User Manual MFCS TM -EZ User Manual MFCS TM -EZ Version 6A_December 2016 1. INTRODUCTION 5 2. GENERAL INFORMATION 6 2.1 General functioning 6 2.2 Different MFCS TM 6 3. PACKAGE CONTENT 8 4. MFCS TM -EZ DESCRIPTION 9 5. CONNECTIONS

More information

Hand-held pressure calibrator with integrated pump Model CPH6600

Hand-held pressure calibrator with integrated pump Model CPH6600 Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control

More information

6800 Maintenance Instruction System Flush Procedure

6800 Maintenance Instruction System Flush Procedure Equipment Required FA74005 FA65318 FA900005 FA900003 Damper Drain Tube 6800 Cover Removal Tool Beaker 0.25 Litre Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves

More information

User Manual. Precision and Analytical Balances ME-T

User Manual. Precision and Analytical Balances ME-T User Manual Precision and Analytical Balances ME-T Overview balance 0.1 mg 1 mg 9 9 5 7 7 6 4 1 3 2 1 10 mg~0.1 g 2 3 4 5 7 6 12 5 13 1 14 2 3 10 11 8 Balance overview legend 1 Capacitive color TFT touch

More information

Safety instructions and operating manual

Safety instructions and operating manual 5-Master Safety instructions and operating manual TBF-PyroTec GmbH Lichterfelder Str. 5 A 21502 Geesthacht Tel.: + 49 (0)4152 157 9950 Fax: + 49 (0)4152 157 9951 Flame projector 5-Master Safety instructions

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information