IECEx Cert f cate. of Conformity

Size: px
Start display at page:

Download "IECEx Cert f cate. of Conformity"

Transcription

1 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEG Gertification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit Certificate No. Status: issue No.:1 Gurrent Page 1 of 5 qertitçqle histgry; lssue No. 1 ( e) lssue No. 0 ( ) Applicant: General Monitors lnc Simpatica Circle Lake Forest California United States of America Electrical Apparatus: Optional accessory: Model S4000CH, S4000TH and Model TS4000H lntelligent Gas Sensorc Type of Protection: Flameproof Marking: Model S4OOOCH Ex d llb+hz T5 Gb (Ta 40'C to +70'C) Model S4OOOTH Ex d llb+h2 T5 Gb (Ta -40"C to +70"C) Model TS4OOOH Ex d llb+h2 T5 Gb (Ta -40'C to +70'C) Approved for rssue on behalf of the IECEx Ceftification Body: Position: C Ellaby Deputy Certifi cation Manager Signature: (for printed version) Date: Lol 'l? This certificate and schedule may only be reproduced in full 2. This certifìcate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: SIRA Certifi cation Service Rake Lane Eccleston Chester CH4 gjn United Kingdom srra, I CERTIFICATION csa 0roup

2 Certificate No.: Manufacturer: 2014-', 2-'.19 General Monitors lnc Simpatica Circle Lake Forest Galifornia United States of America Page 2 of 5 Additional Manufacturing location (s): General Monitors lreland Limited Ballybrit Business Park Galway lreland This certifìcate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC : 2011 Edition: 6.0 IEC : Edition: 6 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" This Ceftificate does not indicate compliance with electrical safety and pefformance requirements other than those expressly included in the Sfandards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed /has successfully met the examination and test requiremenfs as recorded in Test Reoort: GB/SlR/ExTRl GB/SlR/ExTR /00 Qualitv Assessment Reoort: GB/StR/QARo7.0014/03 us/uuq4r /01

3 B IECEx Cert f cate Certificate No. 20'14-12-'19 Page 3 of 5 Schedule EQUIPMENT: Equipment and sysfems covered by this ceftificate are as follows: The Model S4000CH and S4000TH Intelligent Gas Sensor is intended to detect the presence of hydrocarbon or hydrogen sulphide gases in air. It comprises a two-paft rectangular enclosure and a Universal Gas Sensor manufactured by General Monitors (IECEx SIR U). The main enclosure is manufactured from cast aluminium alloy or stainless steel and consists of a base, with mounting lugs on its two longer sides, and a flanged cover, these may be powder coated. The main enclosure contains the equipment electronics and a seven-segment display. The cover is attached to the base by four M6 recessed socket head cap screws having a property class of B,B and contains a glass window to allow the display to be viewed. The base has four female 3/q" cable entry holes tapped into its side walls; the / " containing the Universal Gas Sensor. All variants of the Model Intelligent Gas Sensor use the same main enclosure and have the following electrical parameters. U nom 24 Vdc; Ui 36 Vdc; Pi 7 W The Universal Gas Sensor has two forms, the HC Head and the H2S Head Both options use the same enclosure with only the internal arrangement differing. They are manufactured from stainless steel and are cylindrical in shape with a hexagonal shoulder in the middle. One end has a 250.rm sinter fused into the enclosure to allow gas penetration to be detected by the internal equipment, the other end contains a setting compound through which the equipment wiring passes. Ay4" thrcad form allows it to be mounted into the main enclosure. The equipment is fitted with O-rings for the prevention of water and dust ingress and have been independently tested according to the requirements of IEC to meet IP 66. Refer to EQUIPMENT (continued) for Design Options and Conditions of Manufacture. CONDITIONS OF CERTIFICATION: YES as shown below: 2 When alternative detectorelements are utilised, they shall only be mounted remotely in a suitably certified enclosure in accordance with the requirements of their respective certificates and relevant local requirements. The associated cable shall be connected to the lntelligent Gas Sensors using a suitably certified, cable entry device with a %" thread form. The maximum constructional gap (ic) is less than that required by Table '1 of IEC and hence is as detailed below: Description Form Maximum Gao (ic) Minimum Lenoth ll') Between the main body and Flange 0.1mm 11.30mm cover Between the olass and the cover Flanoe 0.1mm 13.49mm

4 IECEx Certif cate Certifìcate No ',12-19 Page 4 of 5 EQU IPMENT(contin ued): i i -.-D-99'-s" oetions'äiiiäìi-iëiõiôïëlé-riré'nts may be used, but onty at remote locaiioñj v a aðúi ài;þ' Ë tþ eriiry ðêüiäj ì i and when mounted in accordance wiih the requiremenis detailed in their respective certificates and iocal i -. i - if -st?!le!iql -req! i r-e-nç-n! i The cover r ay b9 manufactured without the viewing-win9.-oyr-.._ : The alternative cable e.n!ry_!h.r_9eg.f9.rnç.7..1il-..n.p..r_atç-in_ql_q9_ç9, räë öäj -d -bã -i ää ü; i Nióti èï ïö õô-ö.h' õäìïäðä J öf ä aê ù n f ätted wi iñ an lntelligent Sensor Toxic Gas lnterface Module Type TS4000(H) to Certificate No. le$cex SIR U. The TS4000H is intended to detect the presence of toxic gases or the amount of oxygen present in the atmosphere. All TS4000H models have the following :.99..Y..4ç.1i'..s..Wi.ß3.le9..yelle.e.e.i.?f..Ygç... lntelligent Sensor Toxic Gas lnterface Mod ule Type TS4000(H) may be fitted with one of the following electro- chemical cells: lhan21%) Gonditions of manufacture T ç Me!cleç!!tql9 ell çgqrply with lhelqlewitrs' 4. TS4000H shall be limited to 1 W t.oorate previousry certified devices, it is therefore the lly monitor the status of the certification associated with form Sira of any modifications of the devices that may!tr-ei.tprs-q-u-ç!9, _ irç{ _w Lth.th g.i.!lr.r.qe.{. t-o_r_n. lntelligent Sensor Toxic Gas lnterface Module Type

5 Gertificate No lssue No.: 1 Page 5 of 5 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): lssue 1 - this lssue introduced the 1 The prevention of water and dust ingress and have been independently tested according to the requirements of EN to meet lp 66, having been lp65 previously. The description was amended to show the new lnqress Protection ratinq. 2. The recognition of minor drawing modifications; Additional colour configurations and notes; these amendments are administrative or involve changes to the design that do not affect the aspects of the product that are relevant to explosion safetv.

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No.

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No. IECEx Cert f cate of Gonform ty INTERNATIONAL ELECTROTECHNIGAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.tecex.com Certificate No.

More information

slra of Gonformity IECEx Cert f cate )ol4- ob cst

slra of Gonformity IECEx Cert f cate )ol4- ob cst IECEx Cert f cate INTERNATIONAL ELECTROTECHNICAL COMMISSION IEG Gertification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.lecex.com Certificate No. Status: Applicant:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:

More information

@h..p. lntertek. IECEx Certificate of Conformity

@h..p. lntertek. IECEx Certificate of Conformity ECEx Certificate of Conformity NTERNATONAL ELECTROTECHNCAL COMMSSON EC Certification Scheme for Explosive Atmospheres for rules and details of the ECElC Scheme visit www.iecex.com Certificate No.: { ECclC

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

UHrasonic Sensor VEGASON60 type series SN6*.CI**H*** Certificate No.: IECEx PTa 06.0099X Issue No.: 0 Status: Current Date of Issue: 2006-12-27 Page 1 of 3 Applicant: VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Electrical Apparatus: Optional

More information

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom Certificate Number: MASC MS/11-358X Issued: 22 September 2014 Expire: 22 September 2015 Page: 1 of 5 IA CERTIFICATE (Revision 3 Revised for Annual Review) IN TERMS OF REGULATION 21.17.2 OF THE MINERALS

More information

Certificate of Conformity

Certificate of Conformity Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocols:

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST

More information

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual

More information

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm 0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush

More information

Certification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT

Certification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT Certificate of Conformity Certificate No: ANZEx 11.2002X Issue: 0 21 March 2011 Original Issue Issue: 1 6 November 2012 Modification Issue: 2 27 August 2013 Modification Issue: 3 6 August 2014 Additional

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories

More information

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar) Assembly instruction 1 2 3 4 5 6 7 1. Entry Component 2. Compound Sleeve 3. Interlocking Armour Cone 4. Armour Clamping Ring 5. Gland Body 6. Outer Sheath Sealing 7. Dome Nut 8. Compound 8 Operating temperature

More information

Pressure switch, Differential pressure switch and Thermostat RT-E

Pressure switch, Differential pressure switch and Thermostat RT-E Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design Elesa Standards Main dimensions Fitting Weight Code Description L B f ±0.2 f 1 ±0.2 H h 1 h 2 d 3 d 4 C [Nm]# g 426601 CFSW.110-6-2NO+2NC-C-A

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type

More information

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review) Certificate Number: MASC MS/11-127X Issue: 09 October 2017 Expire: 09 October 2020 Page: 1 of 5 IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

More information

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017 Procedure Instruction of program Explosion Pressure - Test Round 2017 Content 1 General Performance... 2 2 Measurand / Characteristic of interest... 2 3 Test Item and Configurations... 2 3.1 Components...

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design technical informations Material - Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black colour. Resistant to solvents,

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment

More information

The evolution of the Ex-proof flame path

The evolution of the Ex-proof flame path April 2017 The evolution of the Ex-proof flame path As written in previous dissertation, the most critical part of a flameproof enclosure 'Ex d' is the flame path. Although the Standards are divided into

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres Page 1 of 7 Title Plan electrical installations for explosive atmospheres Level 5 Credits 8 Purpose This unit standard is intended for use in the training and assessment of people who work with electrical

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAA0000123 This is to certify: That the Pressure Transmitter with type designation(s) SITRANS P series DS III, P310, P410 Issued to Siemens AG - Process Industries

More information

Perpetua Power Puck Solutions

Perpetua Power Puck Solutions Perpetua Power Puck Solutions Product Data Sheet October 2015 00813-0100-4404, Rev AA Continuous, long-life power for wireless transmitters High transmitter update rates without battery life impact Intrinsically

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions

More information

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus Page 1 of 7 Title Conduct a conformity assessment of explosion-protected apparatus Level 6 Credits 9 Purpose This unit standard covers the assessment and certification of explosion-protected apparatus

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable

More information

February Cable glands For general industry and hazardous areas

February Cable glands For general industry and hazardous areas February 2017 Cable glands For general industry and hazardous areas Introduction When safety matters, there is only one choice The Nicote and Kopex range of cable glands come to ABB through the acquisition

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting

More information

Further technical information is available on

Further technical information is available on 1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,

More information

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Drawing 1 VA Di ZG1 Ex-d Measured variables actual flow rate

More information

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR

More information

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE Compiled by: Arthur Cameron NOT SO CORRECT SELECTION AND INSTALLATION OF CABLE GLANDS AND JUNCTION BOXES IN HAZARDOUS AREAS

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate No.: IECEx KEM 09.0016 IECEx Certificate of Conformity Date of Issue: 2013-02-22 Issue No.: 3 Page 2 of 4 Manufacturer: Endress+Hauser GmbH+Co. KG Hauptstraße 1 79689 Maulburg Germany Additional

More information

Arran LED Floodlight Luminaire

Arran LED Floodlight Luminaire Arran LED Floodlight Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical

More information

Mechanical Pressure Measurement

Mechanical Pressure Measurement Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement

More information

780S Ultra High Purity Series

780S Ultra High Purity Series Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board

More information

Operating Instructions

Operating Instructions Operating Instructions Sensors Type 705 H 2 S Sensor and Transmitter for Electrochemical Cells Ul Certified HELPING TO MAKE A SAFER WORLD Ensure that you read and understand these operating instructions

More information

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY CERTIFICATE OF CONFORMITY No. ROSS US.GB05.V03061 Valid from 8/12/2010 through 8/12/2013 No. 0422555 CERTIFICATION AGENCY ROSS RU.0001.11GB05 NONPROFIT INDEPENDENT RESEARCH ORGANIZATION (), CERTIFICATION

More information

Certificate of Compliance

Certificate of Compliance FF0 002 Certificate of Compliance Certificate: 1714037 (LR) Issued to: Emerson Process Management GmbH & Co. OHG Industriestrasse 1 Hasselroth, 63594 GERMANY Attention: Gabriele Blendin The products listed

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the Endura AZ20 / AZ30 measuring system Manufactured by: ABB Ltd Oldends Lane Stonehouse Gloucestershire GL10 3TA has been assessed by Sira Certification

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

Operating Instructions

Operating Instructions Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2419437 Master Contract: 203012 Issued to: ABB Automation Products GmbH 72 Schillerstrasse Minden, 32425 Germany Attention: Ralf Schaffer The products listed below

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Differential pressure

Differential pressure Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at

More information

I/P Transducer Positioner Module

I/P Transducer Positioner Module I/P Transducer Positioner Module VRC P/N: 7958032 Installation, Operation and Maintenance Instructions 2.09 [53.1] 1.30 [32.9] 2.97 [75.5] 0.78 [19.8] 0.18 [4.4] 1.42 [36.1] n.18 MOUNTING HOLES (2) PLACES

More information

XCE: Explosionproof Control Enclosures

XCE: Explosionproof Control Enclosures XCE SERIES XCE: Explosionproof Control Enclosures FEATURES 64 standard sizes available Pre-drilled for hinges (hinges optional) Pre-drilled for sub-panel (sub-panel optional) One-piece, NEMA 4 water-tight

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Pressure control, differental pressure control and thermostat Type RT

Pressure control, differental pressure control and thermostat Type RT MAKING MODERN LIVING POSSIBLE Technical brochure Pressure control, differental pressure control and thermostat Type RT Hydrocarbons www.danfoss.com/hydrocarbons Contents Page Introduction...3 Approvals...3

More information

Certificate of Conformity

Certificate of Conformity Certificate of Conformity Certificate Holder: CCG Cable Terminations (PTY) LTD 33 37 Forge Road Spartan Industrial Area, Kempton Park 1619 SOUTH AFRICA Electrical Apparatus: A2F, A2FX, and A2FCG Cable

More information

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. General specifications. Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS 1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS EXPLOSION PROTECTION In addition to the type approval and certification of industrial weighing systems concerned with accuracy, equipment that is also

More information

VG5 Supplementary instructions

VG5 Supplementary instructions VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...

More information

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) Stainless steel and plastic enclosures for use in potentially explosive environments R Rittal system partners Perfect

More information

EX-RECESSED CEILING LIGHT FITTINGS

EX-RECESSED CEILING LIGHT FITTINGS EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic

More information

IEGEx Gert f cate. of Conform ty

IEGEx Gert f cate. of Conform ty IEC -O @ =lru IEGEx Gert f cate of Conform ty INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.recex.com

More information

Features. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts

Features. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts FLOAT LEVEL SWITCH The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the genuine Trafag

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Operating Instructions of BROSA tension load cells, types 0111, 0113

Operating Instructions of BROSA tension load cells, types 0111, 0113 Operating Instructions of BROSA tension load cells, types 0, 03. Description of BROSA tension load cells. Structure and function The BROSA type 0 and 03 tension load cells transmit and measure the tensile

More information

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in: XMO2 Panametrics Smart Oxygen Analyzer Applications An oxygen transmitter for use in: Inerting/blanketing liquid storage tanks Reactor feed gases Centrifuge gases Catalyst regeneration Solvent recovery

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

Junction Boxes Series 8118

Junction Boxes Series 8118 > Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres Page 1 of 8 Title Conduct detailed inspection of electrical installations for explosive atmospheres Level 5 Credits 5 Purpose This unit standard is intended for use in the training and assessment of people

More information

SX -X Concentration transmitter for flammable/ toxic gases Zone 1 ATEX (Cat. 2) Ex d IIB+H2 T6 Gb Ex tb IIIC T85 C Db IP6X

SX -X Concentration transmitter for flammable/ toxic gases Zone 1 ATEX (Cat. 2) Ex d IIB+H2 T6 Gb Ex tb IIIC T85 C Db IP6X SX -X -- -- -- -- 025022 260515 Pag. 1/8 SX -X Concentration transmitter for flammable/ toxic gases Zone 1 ATEX (Cat. 2) II 2GD Ex d IIB+H2 T6 Gb Ex tb IIIC T85 C Db IP6X USER AND MAINTENANCE MANUAL OVERVIEW

More information

Ultra High Purity Model 780S

Ultra High Purity Model 780S Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no separate temperature or pressure inputs required Built-in flow conditioner which eliminates velocity-profile

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR DEH SERIES

HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR DEH SERIES HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR PASSION TO PERFORM Filter elements are efficient only if their dirt holding capacity is fully exploited. This is achieved by using filter housings equipped

More information

IP 69 Protection against water under pressure

IP 69 Protection against water under pressure 44 he European echnical Standard DIN EN 50 262 Metric cable glands for electric installations - the end of the PG Cable glands threads. he technical standards Cable Glands for cables and conductors with

More information

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

Sinorix MANOB480, MANOCAB, MANOEOL Installation Maintenance

Sinorix MANOB480, MANOCAB, MANOEOL Installation Maintenance Sinorix MANOB480, MANOCAB, MANOEOL Installation Maintenance Building Technologies 2017-10-24 Control Products and Systems Legal notice Legal notice The specifications and availability are subject to change

More information

Torque Tube TB300 Digital Transmitters

Torque Tube TB300 Digital Transmitters Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

In Ground Buried Uplights

In Ground Buried Uplights In Ground Buried Uplights BIANCHI LIGHTING SERVICES SUTTON CLOSE, EASTCOTE Enrico Bianchi Guidance notes for the specification and application of in ground buried uplights. MIDDLESEX HA5 2JX +44 (0)794

More information

ISO Anaesthetic and respiratory equipment Conical connectors Part 2: Screw-threaded weight-bearing connectors

ISO Anaesthetic and respiratory equipment Conical connectors Part 2: Screw-threaded weight-bearing connectors Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 5356-2 Third edition 2012-11-15 Anaesthetic and respiratory equipment Conical connectors Part 2: Screw-threaded weight-bearing connectors Matériel

More information