SWS Option: Well Pressures. SWS Option: Stretch Correction (Corrected depth) SWS Option: MMD (Magnetic Marks Detection) ASEP Products
|
|
- Bryce Golden
- 5 years ago
- Views:
Transcription
1 SWS Option: Well Pressures PART NUMBER L The SmartMonitor can simultaneously measure, display and record depth and up to four different well pressures (for example, Control Line Pressure, Tubing Pressure, Inner and Outer Annulus Pressures). The choice for which pressure to display is easily configured. Even the Grease pressure difference with the Tubing pressure can be displayed. SWS Option: Stretch Correction (Corrected depth) PART NUMBER L The standard depth is uncorrected and is just the measured depth from a measuring head. Choosing the stretch correction option means the depth will be corrected based on a few parameters, such as tension, cable weight and magnetic marks (if available). SWS Option: MMD (Magnetic Marks Detection) PART NUMBER L Magnetic Mark Detection is used to correct depth measurement errors in Open Hole. The SmartMonitor is able to process the following different marking methods: Strong marks with weak marks in between Double marks with single marks in between Single marks The depth where the last mark is recognised is shown on the screen, and also the relative distance to the next mark. An overview of all identified marks is shown in the event viewer table.
2 SWS Option: CCL (Casing Collar Locator) PART NUMBER L The Casing Collar Locator (CCL) signal can be shown on the screen and recorded. The last collar depth is also shown, as well as the relative depth from the last collar. The CCL is used as a reference but is not used for correcting the depth. SWS Option: Pro-Active Safety PART NUMBER L This extra safety option offers the possibility to adjust the maximum pull of the wireline unit to slightly more than needed for the actual operation. This will limit the speed to a safe maximum, and to certain areas (including the surface area and total depth area). Sudden stops and starts will then be avoided. This can all be made even safer when combined with the software package RunPredictor (see well obstructions description below). Special hot spots in the well are identified and the wireline unit will lower the speed to a safe speed before these areas are reached. The speed increases again after the safe passing of that area. SWS Option: Run Predictor Interface PART NUMBER L (SmartMonitor) Well obstructions are identified and assigned in the software package RunPredictor. At any depth only the previous and the next obstruction are shown in the depth gauge. With the RunPredictor, maximum speeds can be set for those areas. The SmartMonitor will decrease the speed at the assigned depth to make sure that the speed is maximized for the whole length of the tool string in that particular area.
3 SWS Option: Run Predictor PART NUMBER L (SmartOffice) RunPredictor can simulate the wireline run. The tension profile is calculated over the length of the whole depth and the results of that simulation are uploaded to the SmartMonitor. The calculated tension window is shown on the SmartMonitor tension gauge. This is live, so as the operator moves the tool down hole, the tension will increase and the window will move, according to the simulation in the gauge. This feature gives the operator an extra safety tool. On the way down hole, big differences can be easily identified and this allows the operator to define major issues on the way back up hole. SWS Option: Constant Speed and Cruise Control PART NUMBER L Because logging tools are becoming more accurate and wells are becoming deeper, a stable speed is even more important: To improve quality of operation (logging) To ensure that the cable is handled correctly The operator can run at a certain speed and then press the cruise control button so the unit will maintain its current speed. A depth and speed setpoint can also be set; after the start command, the unit will accelerate the tool to reach the set depth at the set speed. The set points (shown on the screen as green markers) can be constantly reset. SWS Option: Constant Tension Control PART NUMBER L With the Constant Tension Control option enabled, the SmartMonitor maintains a constant tension range on the cable. This can be used, for example, when a combined logging and drilling operation is taking place. The SmartMonitor also has a built in automatic learning feature so that it can recognise the characteristics of the wireline unit. The tension set point can be changed on the fly and this is shown by a green arrow within the tension gauge.
4 SWS Option: Full Winch Control The SmartMonitor has the capability of controlling the whole winch. The engine and the generator can be controlled. The gearbox can be set from low gear to high gear by selecting Manual High (MH) instead of Manual Low (ML). This can only be done when the system is in a safe state. The brake will be applied automatically. All different parameters are just visible in the System View screen, but all the important parameters will be checked. So in case the coolant temperature is becoming the too high, the operator will be warned. This is the most advanced SmartMonitor system and allows the operator to use the screens to control everything, including: All winch functions Measure heads Lights Camera Cabin climate All relevant information for hydraulic winches and full electric winches will be recorded and is available live at any location in the world. This reliable, live information is very useful for pro-active maintenance. SWS Option: System Parameters View PART NUMBER L For the more advanced wireline units, a Number of technical parameters can be displayed and recorded. These include: Engine RPM Temperature Pressure Supply voltage Current Torque Brake status Many variables can also be displayed on different screens (depending on the type of wireline unit: full hydraulic, electric over hydraulic or full electric). All this information can be sent (live) to an office and can then be used to check the status of the unit, or to assist the operator with operations. SWS Option: Event Viewer The SmartMonitor has an event viewer to give an overview of the following: Users who have logged onto the system System events (such as a broken sensor, a user error or a power supply error) Different operational alarms Other This can be very useful for analysing and troubleshooting at a later date.
5 SWS Option: Acquisition Systems PART NUMBER Eclips L PART NUMBER Wafe L PART NUMBER Logiq and BM-Panel L PART NUMBER Signal Forwarding (KARAT/ONIX/KEDR) TBA The SmartMonitor has a number of different communication protocols to communicate with open hole and/or cased hole data acquisition systems. For example, down hole tension (cable head tension) can be sent from the acquisition system to the SmartMonitor. Depth, speed and tension readings can be sent from the SmartMonitor to the acquisition system or vice versa. SWS Option: SmartVideo PART NUMBER L This option allows you to display views from an IP camera. The camera is controllable (pan, tilt, zoom), and presets are also possible. Different cameras can be positioned for a clear view of the drum from different angles, the measuring head or the well site. These views (together with depth, speed and tension) can be processed, displayed and recorded, also within a redundant system. The video picture can also be transmitted to shore (see Real time visualisation and /or Remote control). SWS Option: Jarring Mode PART NUMBER L E-winches can be supplied with a special jarring mode to increase safety and accuracy. This works as follows: 1. The operator goes to a certain depth (jar tool in) 2. The operator then pushes a button and goes to the jar depth (jar tool out) The system then remembers the precise jar length and is able to jar at a desired (but adjustable) speed exactly between these two limits. The maximum tension is limited to the pre-set alarm value set in the wire package.
DataCan. Linewise System. Description. Hardware. Applications
Linewise System Description The Linewise System is a basic acquisition system comprised of hardware and software that records and displays simple process measurements. Examples of these include: depth,
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationMud Diver. Suspended solids level measurement and tank profile station for Clarifier, Thickener, CCD and Washer Control Optimisation
Mud Diver Suspended solids level measurement and tank profile station for Clarifier, Thickener, CCD and Washer Control Optimisation INTRODUCTION INTRODUCTION SmartDiver is a ruggedized automatic mud diver
More informationBUYER S GUIDE AQUAlogger 530WTD
OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 530WTD Wireless Temperature and Depth Logger AQUAlogger 530WTD The AQUAlogger 530WTD has an innovative design that includes the ability to transfer stored
More informationProduct Guide. Crawler Crane
Crawler Crane 220 US Tons (100 Metric Tons) @ 16 ft 5 in Radius 285 ft Max Tip (Main Boom) Main Boom, Fixed Jib and Luffing Jib Configurations Product Guide KEY FEATURES ULTRA CAB The Ultra Cab, designed
More informationSection Freepoint Service 26.1 FREEPOINT CONTROL PANEL
Section 26 26 Freepoint Service The Warrior system supports Freepoint tools that do not require motorized deployment. This includes Applied Electronics Bowspring and Magnetic tools and Homco tools. Other
More informationBoyle s Law: Pressure-Volume Relationship in Gases
Boyle s Law: Pressure-Volume Relationship in Gases The primary objective of this experiment is to determine the relationship between the pressure and volume of a confined gas. The gas we will use is air,
More informationUsER manual for Watersens ph -REDOX
UsER manual for Watersens -REDOX Cl 8 1 2 6 3 3 7 7 4 4 4 4 Parts List 1 Redox Probe 1 x 2 PH Probe 1 x 5 Tube Weight 2 x 6 Connection Valve 1 x chlorine 3 Chlorine and Pumps 2 x 7 Dosing Valve 2 x 5 5
More informationMetham Aviation Design Limited, Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)
Contents Page General Information 1 Items Supplied 1 Variants 1 Compatibility with other products 1 Fitting a Housing 2 Mounting a Bowler 3 Safety Precautions 4 Control Connections 5 Setting up a Bowler
More informationBurner Management System DEMO Operating instructions
Burner Management System DEMO Operating instructions Burner Management System DEMO Operating Instructions Startup Summary - Normal startup is accomplished in four basic steps: 1. Leak Test a. Safety Valve
More informationAPA software instruction manual
1. Starting the program In order to start the control software for the APA device press APAxx shortcut located on the desktop of the supplied computer. XX corresponds to the current software version. When
More informationUSER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM
USER MANUAL OPERATION AND THE USE OF A CAR WITH Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM Page 2 / 8 Table of csontents 1. STARTING THE ENGINE... 3 2. CONTROL PANEL... 3 2.1 Indication of the current
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationLow Pressure AutoChoke Console Precise wellbore pressure control for your underbalanced and managed-pressure drilling operations
Low Pressure AutoChoke Console Precise wellbore pressure control for your underbalanced and managed-pressure drilling operations High resolution pressure control at your fingertips, during your UBD and
More informationUSER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73
USER MANUAL Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * *) Require software ID: DID-SW-001 1/73 Table of contents 1 General... 3 1.1
More informationARCCOS 360 NEW USER GUIDE
ARCCOS 360 NEW USER GUIDE Table of Contents 1. Getting Started a. Download & Install.2 b. Create Account....3 c. Pair Clubs..4 2. Play a. Starting a Round..5 b. Shot Editing.6 c. Shot List.7 d. Flag &
More informationSomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings
SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.
More informationHow many intakes can I operate from the control center? Up to 4 intakes can be controlled from the control center.
FAQs SYSTEM FUNCTIONALITY What is the maximum operating pressure? The maximum system operating pressure is determined by the equipment on the truck and not limited by the SAM system. Since the maximum
More informationLX Compass module 3 Electronic compass device User manual
LX Compass module 3 Electronic compass device User manual LX navigation d.o.o., Tkalska 10 SLO 3000 Celje, tel: + 386 3 490 46 70, fax: + 386 3 490 46 71 info@lxnavigation.si, http://www.lxnavigation.com
More informationHyperSecureLink V6.0x User Guide
HyperSecureLink V6.0x User Guide Note: This software works with the LS-30 Version (06.0x or later) 1, Hardware Installation: 1-1, Connection Diagram for USB or RS-232 Computer Interface To LS-30 CM1 To
More informationFIG: 27.1 Tool String
Bring up Radioactive Tracer service. Click Acquisition Box - Edit - Tool String Edit the tool string as necessary to reflect the tool string being run. This is important to insure proper offsets, filters,
More informationGNX 120/130. Owner s Manual
GNX 120/130 Owner s Manual March 2016 190-01846-00_0B All rights reserved. Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of Garmin. Garmin reserves
More informationREACTOR 40 MECHANICAL Configuration Guide
REACTOR 40 MECHANICAL Configuration Guide Important Safety Information WARNING See the Important Safety and Product Information guide in the product box for product warnings and other important information.
More informationAUTOMATIC HOSE TEST UNIT, TYPE SPU
VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE
More informationSCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties
Quick Installation Guide Doc nr.: 9.17.052H Date: 10-12-2015 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or
More informationProtec P3000 (XL) Helium Sniffer Leak Detector
Protec P3000 (XL) Helium Sniffer Leak Detector AC C U R AT E, R E L I A B L E L E A K DETECTION AT A DISTANCE Sniffer leak detection you can rely on INFICON Protec P3000 and Protec P3000XL Helium Sniffer
More informationHOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.
EASY AND COMFORTABLE TO USE FOR FOOLPROOF OPERATION After the initial setup, there is no need to access the base unit, which frees the operator to concentrate on the sniffing process. All relevant messages
More informationAIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT. Technical Brochure ON RUNNING ENGINES
AIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT ON RUNNING ENGINES Technical Brochure 2015 Introduction The presence of air in the fluid of a working hydraulic system can cause significant performance
More informationGV Standard X-Vent. Setup, Commissioning & Installation Guide
GV Standard X-Vent Setup, Commissioning & Installation Guide Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.
More informationPanther 5 Acute Care Ventilator
1 HIGHLIGHTS High performance and advanced features target the ICU environment Utilizes an internal blower with a specially designed flow control valve removing the need for using compressed air without
More informationUBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions
Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM
More informationSCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual
SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel DTLS Manual This document contains proprietary information. Copyright 2015 Scientific Data Systems, Inc. All rights reserved. 1 Depth Tension
More informationAUTOMATIC DREDGING PROFILE AND CONTOUR CONTROL
AUTOMATIC DREDGING PROFILE AND CONTOUR CONTROL Jay Wise 1 ABSTRACT Phillips and Jordan, a leading excavating and disaster recovery contractor, was faced with the challenge to manage a civil contract involving
More information2. USER INSTRUCTION. Table of contents: Pg.1/14 N:\FAP-2000: LWP
Pg.1/14 2. USER INSTRUCTION. Table of contents: 2.1 SHORT PANEL DESCRIPTION...... Pg.2 2.2 AUTOPILOT TAKE-OVER & MODE SELECTION....... Pg.3 2.3 AUTOPILOT FUNCTIONS....... Pg.3 2.4 THE SPECIAL FUNCTION
More informationCCT-7320/ROC-2313 Reverse Osmosis Controller
CCT-7320/ROC-2313 Reverse Osmosis Controller 1 General The instrument is a combined control instrument of a reverse osmosis controller and an on-line conductivity instrument. It can perform the operation
More informationGuidelines on Surveys for Dynamic Positioning System
Guidelines on Surveys for Dynamic Positioning System (2002) BEIJING 1 CONTENTS Chapter 1 GENERAL 1.1 General requirements 1.2 Class notation 1.3 Definitions 1.4 Plans and documents 1.5 Failure mode and
More information955730_1 4/17/18. FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays
955730_1 4/17/18 FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays Contents System Setup and Operation...3 Configuring Monitor for FlowSense...3 FlowSense Setup...4 Liquid Alerts...8 Monitoring
More informationA4 Operation Manual. Fig.1-1 Controller Socket Diagram
A4 Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and
More informationScanFish Katria. Intelligent wide-sweep ROTV for magnetometer surveys
ScanFish Katria Intelligent wide-sweep ROTV for magnetometer surveys User-friendly control and monitoring software solution The ScanFish Katria comes with the ScanFish III Flight software, which is an
More informationPIRANHA I & 2 OPERATION GUIDE
PIRANHA I & 2 OPERATION GUIDE Thank You Thank you for purchasing a Piranha fishfinder from Humminbird, America s #1 Manufacturer of quality consumer marine electronics WARNING! This device should not be
More informationA4s Operation Manual
A4s Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and
More informationTechnology. Using Bluetooth
Bluetooth is a communication technology that makes it possible to send and receive data without using wires. Using the Bluetooth features, you can set up a wireless connection between your NXT and other
More informationCompletion Workover Riser System. Enabling efficient operations by reducing interface complexities and minimizes operational risk
Completion Workover Riser System Enabling efficient operations by reducing interface complexities and minimizes operational risk Well integrity with fatigue management were key drivers for our system design
More informationRoller AC Servo System
Safely Instruction Roller AC Servo System HMI-15 User Manual Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller
More informationOperating Instructions Part No
DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0578 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service
More informationPART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3
PART 5 - OPTIONS CONTENTS Para Page 5.1 SYSTEM EXPANSION 5-3 5.2 SENSORS 5-3 5.2.1 Trim Angle Sensor 5-3 5.2.2 Mast Rotation Sensor 5-3 5.2.3 Heel Angle Sensor 5-3 5.2.4 Barometric Pressure Sensor 5-3
More informationDesign Envelope Booster. Sequence of operation
Design Envelope Booster Sequence of operation File No: 62.835 Date: february 11, 2015 Supersedes: 62.835 Date: july 11, 2014 sequence of operation Design Envelope Booster 2 general The packaged domestic
More informationOPERATIONS AND MAINTENANCE MANUAL WINCH OPERATORS PANEL AMS4A041
OPERATIONS AND MAINTENANCE MANUAL WINCH OPERATORS PANEL AMS4A041 TABLE OF CONTENTS SECTION DESCRIPTION 1.0 GENERAL DESCRIPTION 2.0 DETAILED DESCRIPTION OF FEATURES 3.0 MENU OPERATING INSTRUCTIONS OPEN
More informationDRILLSCENE PROACTIVE DRILLING DECISIONS
DRILLSCENE PROACTIVE DRILLING DECISIONS RISE TO THE CHALLENGE OF REAL-TIME DRILLING CONTROL Today s oil and gas drilling operations present significant technical challenges in remote locations and increasingly
More informationElectronic Automatic Transmission for Bicycle
Electronic Automatic Transmission for Bicycle Team 4 Tianqi Liu, Ruijie Qi, and Xingkai Zhou ECE 445 Project Proposal Spring 2018 TA: Hershel Rege 1 Introduction 1.1 Objective Nowadays, an increasing number
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationGNX 20/21. Owner s Manual
GNX 20/21 Owner s Manual Table of Contents Introduction...1 Device Overview... 1 Using the Race Timer... 1 Profiles... 1 Selecting a Profile... 1 Restoring Profiles to their Default Settings... 1 Instrument
More informationRESOLUTION MSC.94(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR NIGHT VISION EQUIPMENT FOR HIGH-SPEED CRAFT (HSC)
MSC 72/23/Add.1 RESOLUTION MSC.94(72) EQUIPMENT FOR HIGH-SPEED CRAFT (HSC) THE MARITIME SAFETY COMMITTEE, RECALLING Article 28(b) of the Convention on the International Maritime Organization concerning
More informationAX5000 Operational Manual
MIYACHI AMERICA CORPORATION The World Leader in Hermetic Sealing Systems AX5000 Operational Manual 0 Document #107-00092-001 Dec, 2013 AX5000 Operational Manual Miyachi America Corporation 1820 S. Myrtle
More informationACV-10 Automatic Control Valve
ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,
More informationProduct highlights Variable frequency and thrust
Innovative engineering for extreme global environments FT550 - VIBROCORER The 3rd generation FT550 lightweight variable frequency high power vibrocorer leads the market in its technical innovation and
More informationOPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9
Estimated kerf width compensation The widths in the chart below are for reference. Differences between installations and material composition may cause the specific user results to vary from those shown
More informationFRDS GEN II SIMULATOR WORKBOOK
FRDS GEN II SIMULATOR WORKBOOK Trotter Control Inc 2015 Document# Revision Revised 9001-0038 FRDS GEN II Simulator Workbook E 02/15/2015 by DC FRDS GEN II Simulator Workbook This workbook is a follow-on
More informationSG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection
SG36KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG36KTL-M. In no case shall this guide substitute for the user manual or related notes on
More informationDrift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer
Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer M. F. Vineyard, T. J. Carroll, and M. N. Lack Department of Physics University of Richmond, VA 23173 ABSTRACT The
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More information955108_2. AirForce Operator s Guide
955108_2 AirForce Operator s Guide Contents System Setup and Operation...3 AirForce Setup...3 Load Cells...6 AirForce Control...8 How to Set AirForce...11 Home Screen...13 AirForce Diagnostic Information...15
More informationDynamic Positioning Control Augmentation for Jack-up Vessels
DYNAMIC POSITIONING CONFERENCE October 9-10, 2012 Design and Control Session Dynamic Positioning Control Augmentation for Jack-up Vessels By Bradley Deghuee L-3 Communications 1 Introduction Specialized
More informationProduct Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12
Product Information Three in One: Gas Meter Tariff Device Volume Corrector Ultrasonic Gas Meter ECOSONIC X12 ECOSONIC X12 Values you can count on The Application Fields The ultrasonic gas meters of the
More information1. Outline of the newly developed control technologies
This paper describes a vertical lifting control and level luffing control design for newly developed, fully hydraulicdriven floating cranes. Unlike lattice boom crawler cranes for land use, the floating
More informationINNOVATIVE MOORING SYSTEMS
INNOVATIVE MOORING SYSTEMS VESSEL AUTOMOORING MODULES QUAY AUTOMOORING INSTALLATIONS DOCKLOCK brings mooring to a next level PAGE 2 FOR OVER A CENTURY THE WORLD S LEADING EXPERT IN MOORING, BERTHING AND
More informationAUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP
USER MANUEL AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP TIRE EQUIPMENT MANUFACTURER 1.866.409.RACK WWW.MARTINSINDUSTRIES.COM info@martinsindustries.com PARTS Verify that the following components
More informationOperating Instructions Part No
DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0545 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service
More informationAir Bubbler Depth Gauge DG2200 Installation and Reference Manual
Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Rev. 3.2.2 06/2011 Installation and Reference Manual Page 2 Contents Chapter 1: Installation and Overview... 3 1.1 DG2200 Location Diagram...
More informationSF 6 Product Guide. Gas Analysis Instruments and Accessories
SF 6 Product Guide Gas Analysis Instruments and Accessories Cambridge Sensotec Ltd specialises in the design and manufacture of gas analysis equipment under the Rapidox brand name. Based in the UK, the
More informationUser manual CF8-D/W-IN
User manual CF8-D/W-IN General The sensor CF8-D/W-IN is used to measure the carbon dioxide concentration inside incubators. All functions can be modified from a PC with the communication cable. UMA 48
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationQuick Installation Guide Doc nr.: C Date:
Quick Installation Guide Doc nr.: 9.17.093C Date: 13-05-2016 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or
More informationRAMSTM. 360 Riser and Anchor-Chain Integrity Monitoring for FPSOs
RAMS 360 Riser and Anchor-Chain Integrity Monitoring for FPSOs Introduction to RAMS Tritech s RAMS is a 360 anchor-chain and riser integrity monitoring system for Floating Production Storage and Offloading
More informationCommercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1
Commercial Softeners Installation, Operation & Maintenance Guide Manual 002.1 Contents Page 1. Unpacking Instructions 3 2. Installation 3 Pre-installation checks Fitting the bottom distribution system
More informationSCIENCE LAB UTILITY CONTROLS
SCIENCE LAB UTILITY CONTROLS INCORPORATING GAS PRESSURE PROVING GAS PRESSURE PROVING EQUIPMENT - ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY THE MERLIN RANGE DESIGNED FOR EDUCATIONAL LABORATORIES
More informationPowerDrive X6. Rotary Steerable System for high-performance drilling and accurate wellbore placement
Rotary Steerable System for high-performance drilling and accurate wellbore placement The PowerDrive X6 RSS maintains control under the most difficult conditions, bringing the benefits of rotary steerable
More informationScience&Motion. SAM BalanceLab. Sports. control the invisible. Most advanced pressure plate for coaching
SAM BalanceLab Science&Motion Sports control the invisible Most advanced pressure plate for coaching Balance - the invisible key to success Stop the guesswork and start to rely on facts Science and Motion
More informationCASE STUDY. Compressed Air Control System. Industry. Application. Background. Challenge. Results. Automotive Assembly
Compressed Air Control System Industry Automotive Assembly Application Savigent Platform and Industrial Compressed Air Systems Background This automotive assembly plant was using over 40,000 kilowatt hours
More informationDrilling Efficiency Utilizing Coriolis Flow Technology
Session 12: Drilling Efficiency Utilizing Coriolis Flow Technology Clement Cabanayan Emerson Process Management Abstract Continuous, accurate and reliable measurement of drilling fluid volumes and densities
More informationTouch Screen Guide. OG-1500 and OG Part # T011
Touch Screen Guide OG-1500 and OG-2000 Part # 9000000.T011 Effective 11/2010 External View Internal View 1. Transducer Banks 2. Oxygen Sensor 3. PLC These are the two manifolds with three (3) transducers
More informationDDR Dive Data Recorder Manual - Rel /12
DDR Dive Data Recorder Manual - Rel. 1.1 2/12 TABLE OF CONTENTS 1. WHAT IS THE DDR? 4 2. TECHNICAL CHARACTERISTICS 5 3. DOWNLOADING DATA TO A PC 6 4. DDR MANAGER 7 5. CONFIGURE DEVICE BUTTON 9 6. READ
More informationAIRCRAFT PRIMARY CONTROLS A I R C R A F T G E N E R A L K N O W L E D G E
1.02.02 AIRCRAFT PRIMARY CONTROLS 1. 0 2 A I R C R A F T G E N E R A L K N O W L E D G E CONTROLLING AIRCRAFT AIRCRAFT CONTROL SYSTEM In general, we use control inputs of the following devices in cabin:
More information2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications
Application Description AG/266PILD-EN Rev. C 2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic Pressure Measurement Engineered solutions for all applications Increase plant productivity
More informationTemperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)
Temperature Controller USER S MANUAL Aerotech, Inc. FORM: QM1387 4215 Legion Dr. Mason, MI 48854-1036 USA October 2010 Ph. (517) 676-7070 Fax (517) 676-7078 FOR CUSTOMER USE Enter the serial number located
More informationSENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide Palm OS. Version 2.0 Published October 17, ReefNet Inc.
SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide Palm OS Version 2.0 Published October 17, 2002 2002 ReefNet Inc. 1.0 Introduction The SENSUS PRO data recorder captures the time, depth,
More informationHYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION
HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION Introduction: Hypoxic Air Fire Prevention System is a revolutionary fire prevention technology. It has the unique ability to create a breathable
More informationGyroTracer. Operating Manual. North Seeking Gyroscope (Wire line mode) Version
GyroTracer North Seeking Gyroscope (Wire line mode) Operating Manual Version 1.1.2.1 Follow this user friendly, step by step guide to operate the SPT North Seeking GyroTracer Please handle the GyroTracer
More informationIDeA Competition Report. Electronic Swimming Coach (ESC) for. Athletes who are Visually Impaired
IDeA Competition Report Electronic Swimming Coach (ESC) for Athletes who are Visually Impaired Project Carried Out Under: The Department of Systems and Computer Engineering Carleton University Supervisor
More informationECL Comfort 110, application 131 (valid as of software version 2.00)
Operating Guide ECL Comfort 110, application 131 (valid as of software version 2.00) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /
More informationfrom Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010
from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010 Dewar vessel noun. A container with an evacuated space between two walls, capable of maintaining its contents at a
More informationRemote Control Bait Boat
CARPIO 2.0 User Manual All pictures shown are for illustration purpose only. Actual product may vary due to product enhancement Remote Control Bait Boat (Smart Remote Control at 868 MHz) 1 Table of Contents
More informationSimrad yachting catalog 2007
26 AUTOSTEERING Electronic intelligence combined with powerful and reliable designs make sure you enjoy boating even more. 27 Tillerpilots Enjoy silence when sailing SIMRAD TP SERIES REMOTE COMMANDER High
More informationDepth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition
Depth sensor Product reference : 90-60-456 REV 1 USER GUIDE and INSTALLATION GUIDE nke Sailing competition Z.I. Kerandré Rue Gutenberg 56700 HENNEBONT- FRANCE http://www.nke.fr After sale service n 33
More informationE Cube Lift Model: ECU Installation Instructions
E Cube Lift Model: ECU Installation Instructions 0 E CUBE LIFT INSTALLATION INSTRUCTIONS Please read installation instructions carefully before installation and keep it for future reference. INDEX: Important
More informationTechnology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.
NXT Main Menu My Files Files are automatically placed into the appropriate folders. When you download a program using a Sound file to the NXT, the program will be placed under Software files while the
More informationProduct Overview. Product Description CHAPTER
CHAPTER 1 This chapter provides a functional overview of the Cisco Redundant Power System 2300 and covers these topics: Product Description, page 1-1 Features, page 1-3 Supported Devices, page 1-4 Deployment
More informationSPECIFICATIONS APCEPH1
APCEPH1 ph CONTROLLER SPECIFICATIONS APCEPH1 Input voltage 120 Volts AC Maximum amperage 14.5 amps @ 120 VAC ph Accuracy +/- 0.2 ph ph Control range Adjustable 4.5 8.5 ph Weight < 1 lbs Dimensions 3" x
More informationOFFICIAL MESSAGE CIRCULAR
OFFICIAL MESSAGE CIRCULAR From: NI/ DP Department Number: 010/2012 Date: 20.12.2012 Number of pages: 7 To: Dynamic Positioning Accredited Training Centres Cc: DPTEG members Referent to: Aims and Objectives
More informationNT09-21 Cruise Report SURUGA-BAY Cable Laying Experiment / VBCS Function Test
NT09-21 Cruise Report SURUGA-BAY Cable Laying Experiment / VBCS Function Test December 2009 Table of Contents 1. Overview 2. Schedule 3. Dive Summary 4. Concluding Remarks 1. Overview A unique development
More information