Water Temperature Control - Groups of Fixtures

Size: px
Start display at page:

Download "Water Temperature Control - Groups of Fixtures"

Transcription

1 Digital - Outlook ASSE 1070 Certified Up to six outlets from a single valve Programmable timed flow (independent for each outlet) On/Off or preset timed flow control with either touch or no touch sensors Programmable temperature Programmable service flush Programmable thermal disinfection mode Valve usage data logging capabilities Multiple valves can be data linked together to form a network)) 25

2 Outlook Water Temperature Control - Groups of Fixtures Outlook is a six outlet digital mixing valve which enables precise group fixture flow and temperature control for showering and hand washing applications. Outlook offers a digital solution to facilities seeking compliance prevailing legionella control guidelines. For secure or otherwise controlled institutional showering applications, Outlook is available with a range vandal resistant and antiligature showerheads and is operable by touch/no touch wall mounted sensors. For institutional hand washing applications, Outlook is available with a series of lavatory spouts operable by either integral spout located no touch or touch/no touch wall mount sensors. For the commercial public washroom, Outlook offers a single digital mixing valve option for multiple lavatories where ASSE1070 point of use compliance is required. * Minimum flow rate of 1.5 GPM represents the minimum flow through the six outlet mixing valve for optimum performance. For metered lavatory applications an individual Outlook outlet serving a single fixture meets the requirement of ASME A as referenced in ASSE 1070 of.25gpm per operating cycle. Outlook (gpm) Model Pressure Drop (psi) Min Flow C V Six Outlet Mixing Valve *

3 Outlook Components Flow Control No Touch Infra-Red Wall Sensor for Shower or Lavatory Designed for use in schools, recreation and sports centers and similar buildings where medium duty vandal resistance is desirable. Polymer with Durable Polished Chrome Finish. 2.7 (68 mm).9 (22 mm) 3.3 (84 mm).2 (6 mm) For a submittal drawing, refer to D Shipping Weight: 1.5 lbs. Flow Control Touch Piezo Wall Sensor for Shower or Lavatory Designed for use in prisons, psychiatric facilities and similar buildings where a higher level of vandal resistance is desirable. Stainless Steel..4 (9 mm) For a submittal drawing, refer to D Shipping Weight: 6.5 lbs. 1.0 (25 mm).2 (5 mm) 27

4 Outlook Components Flow Control No Touch Spout Sensor for Lavatory Designed for use in the public washroom. Brass with Durable Polished Chrome Finish. Available in 6 /150 mm, 7 1/2 /190mm and 9 /225 mm lengths. 4.3 (110 mm) 7.3 (185 mm) 5.9 (150 mm) 7.5 (190 mm) 8.6 (225 mm) For a submittal drawing, refer to D Shipping Weight:.5 lbs. Six Outlet Mixing Valve Polymer Enclosure with Brass/Stainless Steel internal components (541 mm) 20.1 (511 mm) (187 mm) (233 mm) 6 x ½ 15 mm (56 mm) (78 mm) (44 mm) For a submittal drawing, refer to D Shipping weight combined with Sensor Control Box: 17 lbs. 3.3 (84 mm) Sensor Box Polymer Electronics Enclosure (255 mm) 5.3 (134 mm) 1.5 (37 mm) For a submittal drawing, refer to D

5 Outlook - Technical Specifications Connections.75 (20 mm) HW (1) & CW (1) inlet flat faced union connections..5 (15 mm) Mixed water outlet (6) flat faced unions Approvals ASSE 1070 BS EN ISO 9001:2008 Quality Management Systems and BS EN ISO 14001:2004 Environmental Management Systems Lead Free Compliant. Operation Wall Sensor flow control: Non-touch ON/OFF. Touch ON/OFF. Non-touch ON/OFF spout. Materials Mixing unit enclosure: PC/ABS. Integral components: DZR brass, stainless steel, engineering plastic. IP Rating Mixer Valve: IP24. Sensor Box: IP20. PSU: IP45. Electrical Specification Supply Voltage: V RMS HZ. 1.5 A Maximum load: 40 W at 12 V DC. Valve to sensor box cable length: 1.5m Sensor box to sensor cable length: 6m. Flow Times and Duty Flush Factory settings Flow time: 30 seconds. Duty flush cycle: 2 minutes. Duty flush waiting period: 3 days. Programmable range Flow time: 5 sec - 60 min. Duty flush cycle: 1 min - 59 min. Duty flush waiting period: 1 hr hrs. Duty flush not enabled at factory, programming required. Temperature Range Factory pre-set: Default 100 F (38 C). Programmable range: Min 86 F (30 C) 116 F (47 C) Maximum: 91 F (33 C) 122 F (50 C) Default 86 F (30 C) 122 F (50 C) at start up, or full cold only can be selected. Minimum blend temperature differential from hot supply: 5 F (2 C). Optimum thermostatic control range: (86 F) 30 C 122 F (50 C). Cold water range (recommended): 1 C - 20 C Inlet Hot water range (recommended): 122 F (50 C) 149 F (65 C) Maximum Inlet Hot Water 185 F (85 C) Temperature stability: ± 2F (1 C) for recommended supply conditions. Pressures Maximum static pressure: 115 PSI (8 bar) Minimum pressure loss: 15 PSI (1 bar) Hot and cold pressure should be nominally equal: Max differential 3:1 Flow Rates Minimum flow rate per outlet:.5gpm (1,4lpm) Environment Ambient temperature: 33 F (1 C) 104 F (40 C). Maximum relative humidity: 95% non-condensing. Suitable for indoor use only. Disinfection Factory settings - Standard Target time: 5 minutes. Max Warm Up: 1 min. Timeout: 10 mins. Target temperature: 140 F (60 C). Programmable range Temperature: 140 F (60 C) F (80 C). Time: 1-59 minutes. Configuration Tool A Laptop/PC is required to adjust factory settings, retrieve data, configure duty flush and disinfection cycles. The programmer software available is designed to run on Microsoft Windows XP/Vista operating systems. Please refer to the appropriate software manual. Sensor Box Web enabling on-line approach and linking on building management network is possible, or sensor box can be linked directly to Building Management System (BMS), via Modbus. Features Connections for 6 control sensors Connect to multiple sensor boxes in a network* (Modbus) Connection for motion (safety) PIR Connection for ventilation circuit * Maximum number of sensor boxes in a single network = 31 29

BrainWave Electronic Mixing Valve Installation, Operation and Maintenance (IOM)

BrainWave Electronic Mixing Valve Installation, Operation and Maintenance (IOM) HWG-700 BrainWave Electronic Mixing Valve Installation, Operation and Maintenance (IOM) This BrainWave Electronic Mixing Valve (EMV) has been supplied for this application based upon information provided

More information

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD ETV Platinum Plus R C O R P O R A T I O N Electronic Tempering Valve DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD Conforms to the following: ASSE 1017 California Lead Free Plumbing Law CSA B 125.3

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

ASSE International Product (Seal) Listing Program

ASSE International Product (Seal) Listing Program ASSE International Product (Seal) Listing Program ASSE 1070-2015 / ASME A112.1070-2015 / CSA B125.70-15 Performance Requirements for Water Temperature Limiting Devices Manufacturer: Contact Person: E-mail:

More information

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Application RA-DV straight version RA-DV is a series of pressure independent radiator valves, designed for use in 2-pipe heating systems together

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700 Series e700 ADA compliant 1016 listed B125 Certified Self-contained cartridge installs in minutes Cartridge retrofits into all Powers Series 900 Pressure Balancing Valves - Model 3 Integral checkstops

More information

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2 The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control

More information

Technical Information Conducal CLY421

Technical Information Conducal CLY421 TI00496C/07/EN/01.12 71142150 Products Solutions Services Technical Information Conducal CLY421 Conductivity calibration set for ultrapure water applications Factory calibrated measurement box Certified

More information

Programmable pressure and temperature transmitters PTM/RS485

Programmable pressure and temperature transmitters PTM/RS485 Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x

More information

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass Introduction Fig. 1 Basic version - A Fig. * Self-acting version with automatic disinfection function - B * thermometer is an accessory

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

LEAD FREE * Product Specification. Features n. Specifications n. Relay Specification n ! WARNING NOTICE

LEAD FREE * Product Specification. Features n. Specifications n. Relay Specification n ! WARNING NOTICE ES-P-SF-INTELLISTATIN IntelliStation Digital Water Tempering and Recirculating System Capacity up to 858 gpm @ 45psi Product Specification LEAD FREE * Features n Configurable on location. Does not require

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

Precision pressure sensor Basic version Model CPT6020

Precision pressure sensor Basic version Model CPT6020 Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications

More information

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 Data sheet Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 The CCMT is an electrically operated valve designed specifically for operation in CO 2 systems. The CCMT valve concept is

More information

Programmable pressure and temperature transmitters PTM/RS485

Programmable pressure and temperature transmitters PTM/RS485 Programmable pressure and temperature transmitters PTM/RS485 Version: 26.06.2014 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x

More information

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N Thermal Mass Flow Meter for Compressed Air and Gases measuring monitoring analysing KMT Measuring range: 0.32... 63 m3n/h... 3.5... 1400 m3 N /h Accuracy: ±2,5% of reading + 0,15% of full scale p max :

More information

Presented to the IAPMO Standards Review Committee on March 7, 2016

Presented to the IAPMO Standards Review Committee on March 7, 2016 Summary of Substantive Changes between the 2015 edition of ASSE 1070/ASME A112.1070/CSA B125.70, Water Temperature Limiting Devices, the 2004 edition of ASSE 1070, Water Temperature Limiting Devices, and

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Pressure independent control valve (PICV) FLOWMATIC

Pressure independent control valve (PICV) FLOWMATIC Pressure independent control valve (PICV) FLOWMATIC 145 series FM 21654 003 01262/19 GB replaces dp 01262/17 GB Function The pressure independent control valve is a device composed of an automatic flow

More information

RA-N radiator valves with integrated presetting and self-sealing tailpiece

RA-N radiator valves with integrated presetting and self-sealing tailpiece Data sheet RA-N radiator valves with integrated presetting and self-sealing tailpiece EN 215 Application Straight version Angle version Horizontal angle version All RA-N valve bodies can be used together

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

Rada Sense Shower T3 DMV PRODUCT MANUAL IMPORTANT

Rada Sense Shower T3 DMV PRODUCT MANUAL IMPORTANT Rada Sense Shower T3 DMV PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 CONTENTS Description...3

More information

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Pilot valves for pilot operated servo valves

Pilot valves for pilot operated servo valves Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

Porter Analytical & Industrial Products

Porter Analytical & Industrial Products Porter Analytical & Industrial Products Porter Analytical & Industrial Products Engineered to Excel in Critical Applications The Porter Instrument Division of Parker Hannifin Corporation is a leading manufacturer

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

CALEFFI. LEGIOMIX Electronic mixing valve series 01086/18.2 NA

CALEFFI. LEGIOMIX Electronic mixing valve series 01086/18.2 NA LEGIOMIX Electronic mixing valve 6000 series CALEFFI 01086/18.2 NA ACCREDITED ISO 9001 FM 21654 ISO 9001 No. 0003 Function The electronic mixing valve is used in centralized systems that produce and distribute

More information

Rada-Presto TF2020 and TF2020S

Rada-Presto TF2020 and TF2020S Rada-Presto TF2020 and TF2020S PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 INDEX Page

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

Applications. Features AWWA ULTRASONIC WATER METER

Applications. Features AWWA ULTRASONIC WATER METER MEASURE TODAY. ENSURE TOMORROW wprime Series 280W-D Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2 Centered (Default) Proportional damper actuator, non-spring return, Multi-Function Technology Torque min. Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) For proportional modulation of dampers in HVC systems. The is

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Tightness control TC. Product brochure GB 3 Edition AGA

Tightness control TC. Product brochure GB 3 Edition AGA Tightness control TC Product brochure GB 3 Edition 07.14 AGA Test of two safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted

More information

UPGRADABLE PRESSURE BALANCE BAT/SOWER FITTING VOLUME AND TEMPERATURE CONTROL VALVE 1-5/8" TO 3-1/ ROUG VALVE OPTIONS 1/2" NPT 1/2" NOM or 1/2" NOM or

UPGRADABLE PRESSURE BALANCE BAT/SOWER FITTING VOLUME AND TEMPERATURE CONTROL VALVE 1-5/8 TO 3-1/ ROUG VALVE OPTIONS 1/2 NPT 1/2 NOM or 1/2 NOM or UPGRADABLE PRESSURE BALANCE BAT/SOWER FITTING VOLUME AND TEMPERATURE CONTROL VALVE MODEL NUMBER: R121 Valve Body Shown R121 Pressure Balance Rough Valve Body only inlets/outlets. LESS trim. Available s

More information

Oxidation Stability of Gasoline and Aviation Fuels

Oxidation Stability of Gasoline and Aviation Fuels Oxidation Stability of Gasoline (Induction Period Method) Oxidation Stability of Aviation Fuels (Potential Residue Method) Test Method Provides an indication of the tendency of gasoline and aviation fuels

More information

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4 to 1 NPT SERIES. qwer Air and Inert Gas Valves Brass, or Stainless Steel Bodies 1/" to 1" NPT Features Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting

More information

RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD - Ultra-Rugged Differential Pressure Flowmeter 0.15-1 to 85-600 GPM Liquids 2.5-25 to 300-1700 SCFM Gases 1/2 to 3 Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available Custom Calibrations

More information

SPCH/ Blowing block

SPCH/ Blowing block > > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3

More information

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure Bacteria/Legionella Protection Is Lower Better? The Other Side to the Coin. It s truly a double-edged sword.

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air

More information

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control VPPC, VPPC -ay proportional pressure control valve, > > Nominal diameter,, flange version G/ > > Visual function display (optional) > > Compact and lighteight design > > Field bus capable as part of a

More information

SonoSelect 10 and SonoSafe 10 energy meters

SonoSelect 10 and SonoSafe 10 energy meters SonoSelect 10 and SonoSafe 10 energy meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

Programmable Submersible Level Transmitters

Programmable Submersible Level Transmitters Programmable Submersible Level Transmitters PTM/N/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available as

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

Scald Protection Three-Way Thermostatic Mixing Valve

Scald Protection Three-Way Thermostatic Mixing Valve CALEFFI www.caleffi.com 383.04 Scald Protection Three-Way Thermostatic Mixing Valve Copyright 00 Caleffi 3 Series Installation, commissioning and servicing instructions Function Scald Protection Three-Way

More information

Harmony. Pressure Independent Balancing and Control Valve

Harmony. Pressure Independent Balancing and Control Valve Harmony Pressure Independent Balancing and Control Valve IMI FLOW DESIGN / Pressure Independent / F376.0 Harmony HARMONY The Harmony delivers a complete hydronic balancing and control solution that optimizes

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

MB610 Industrial Pressure Transmitter

MB610 Industrial Pressure Transmitter MB60 Industrial Pressure Transmitter Features Extreme Impact and vibration resistance, anti-overload, anti-corrosion; Digital compensation, wider operating ambient temperature range; High accuracy, low

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V Installation and Maintenance Instructions 2 1 MIN MAX 7 In this procedure document we have endeavoured to make the information as accurate as

More information

2/2-Way Proportional Valve (motor-driven)

2/2-Way Proportional Valve (motor-driven) 2/2-Way Proportional Valve (motor-driven) Type 3280 can be combined with Seat valve with stepper motor - actuator isolated from flow path Excellent range (1:100) Low power consumption Fast response Orifice

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA

Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) Top or Bottom Supply General Area Table of Contents Pre-Installation Information... 2-3 Components...4 Supplies

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Supplementary Operator s Manual 42/24-14 EN Rev. 3 Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary

More information

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure Bacteria/Legionella Protection Is Lower Better? The Other Side to the Coin. It s truly a double-edged sword.

More information

differential pressure regulating valve - threaded

differential pressure regulating valve - threaded 140-142 differential pressure regulating valve - threaded Introduction Differential pressure regulating valves (DPRV) maintain the differential pressure across a circuit or sub-branch at a set differential

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

QBS Electronic Pressure Regulator

QBS Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBS stainless steel series is an electronically controlled pressure regulator. The QBS controls the pressure on its output port

More information

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing) 1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve INSTALLATION AND MAINTENANCE GUIDE DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve Saving water, saving power, promoting hygiene Important: Read carefully before installing product DOLPHIN Revision

More information

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV Pressure regulator with solenoid valve Air/gas ratio control with solenoid valve Variable air/gas ratio control with solenoid valve VAV Product brochure GB 3 Edition 05.12 AGA All-purpose servo regulator

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

Mass Flow Meter (MFM) for gases

Mass Flow Meter (MFM) for gases Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

Visualize Nitrogen Gas Consumption

Visualize Nitrogen Gas Consumption Air Flow Monitor EWA2 SERIES Conforming to EMC Directive (all models) & Pressure Equipment Directive (AEWA2150/2200 only) Visualize Nitrogen Gas Consumption Small pipe size as Well as Air Consumption!

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES SENSORS FOR MASS FLOW AND PRESSURE CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES INTRODUCTION Bronkhorst High-Tech BV is the worldwide pioneer in the field of low flow liquid metering

More information

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S06* Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

self closing tapware and bubblers AUTOMATIC SHUT-OFF REDUCE WATER WASTE IMPROVE HYGIENE VANDAL RESISTANT Spring Action Series Time Flow Series

self closing tapware and bubblers AUTOMATIC SHUT-OFF REDUCE WATER WASTE IMPROVE HYGIENE VANDAL RESISTANT Spring Action Series Time Flow Series self closing tapware and bubblers Spring Action Series AUTOMATIC SHUT-OFF REDUCE WATER WASTE IMPROVE HYGIENE VANDAL RESISTANT Time Flow Series A joint government and industry program When tested at, 2

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products

More information

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel KROHNE 04/2003 7.02445.71.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel One tube no limits No limits with tube material No limits with

More information

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale EPR-3000 High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale General Specifications PRECISE CONTROL UP TO 3000 PSI The Equilibar EPR-3000 dual valve pressure controller

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual SDI-12 + 4-20mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual (Submersible) WL2100W (Dry) WL2100D QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD 48-50 Scrivener St,

More information

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09 Installation & Maintenance Instructions TEC-11N TIMER Analogue electronic timer 02/09 GENERAL OPERATION The TEC-11N timer is produced using SMT (Surface Mounting Technology), ensuring improved performance

More information

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

2/2-way proportional valve

2/2-way proportional valve 2/2-way proportional valve General purpose 0... 12 bar DN 0.8... 2.0 mm 1/8 or sub-base version Type 2824 can be combined with Type 805 Digital control electronics DIN-rail version Type 07 Cable plug Typ

More information

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings Presented to the IAPMO Standards Review Committee on October 15, 2018 General: The changes to this standard

More information

Pressure Independent Control Valves

Pressure Independent Control Valves Pressure Independent Control Valves Pressure Independent Control Valve The Terminator PICV Pressure Independent Control Valve is a combined constant flow limiter and full stroke, full authority, equal

More information