4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

Size: px
Start display at page:

Download "4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES."

Transcription

1 qwer Air and Inert Gas Valves Brass, or Stainless Steel Bodies 1/" to 1" NPT Features Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting safety barriers. Acceptable for use in hazardous locations, as classified by the National Electrical Code: Classes I, II, and III, Division 1, including Groups A through G. Electronically enhanced solenoids have efficient cartridge operators and nonpolarized coils with triple redundant blocking diodes. Capacitor stores power required to open the valve, while blocking diodes prevent it from flowing back into the wiring in the hazardous area. Mountable in any position. % # ) 2/2 3/2 /2 SERIES Construction Valve Parts in Contact with Fluids Body Brass Stainless Steel Seals and Discs NBR, FKM, or CR Sleeve 30L Stainless Steel Core and Plugnut 30F Stainless Steel Core Springs 302 Stainless Steel Pilot Seat Cartridge CA (Series 8316 and 83 only) Rider Rings PTFE Spring Retainer CA Solenoid Enclosures Standard: Watertight, Type. Optional: For 316 Stainless Steel, metal Watertight Box, Type X (on brass bodied valves), specify prefix "WS" instead of "WP". For DIN IP65, specify prefix "ISSC". For Liquid Crystal Polymer, Watertight, Type 1, 2, 3,, and X, specify prefix "WB". See Optional Features Section for other available options. Electrical Normal Operating Voltage 2 volts DC, ±10%. Maximum Allowable "Off" State Current to the Valves must be less than 1 ma. Electronically Enhanced "IS" Solenoid: Maximum Capacitor Charge Time 1 second Minimum Time between Cycles 1 second Minimum Drop Current to Reset Electronic Coil 2 ma Nominal Temperature Rise at 2 VDC and 300 Ohms 2 C (36 F) Maximum Recommended Wire Run (#18 Wire) 1.5 miles from barrier to valve Important: Minimum series resistance of 200 ohms required in wiring circuit if a safety barrier is not used for non-"is" system. Maximum Operating Current (amps)= V - 2. R B+ R L+ 150 Maximum Charging Current (amps)= V R B+ R L+ 52 V = Supply Voltage R B= Barrier or Current Limiting Resistance R L= Line Resistance (wiring) Nominal Ambient Temperature Ranges: 831, 8362, 8317: -0 F to 10 F (-0 C to 60 C) All other: - F to 10 F (-20 C to 60 C) Refer to Engineering Section for details. Approvals: FM approved under J.I.3W8A8. AX (3610). CSA certified under File LR C. CENELEC EEx ia IIC T6 approved. Meets applicable CE directives. Refer to Engineering Section for details. Important: These solenoids are intended for use on clean, dry air or inert gas filtered to 50 micrometers or better. To prevent freezing, the dew point of the media should be at least 18 F (-8 C) below the minimum temperature to which any portion of the clean air or gas system could be exposed. Instrument air in compliance with ANSI/ISA Standard S (R1981) exceeds the above requirements and is, therefore, an acceptable medium for these valves. Operating Parameters Entity Groups A-D Groups C-D Parameters V max - 30 VDC V max - 3 VDC I max ma 86 F (30 C) Maximum Series Resistance in Ohms Maximum Holding Current with 300 Ohm Barrier Nominal Coil Watts with 300 Ohm Barrier I max ma Capacitance = 0 Capacitance = 0 Inductance = 0 Inductance = 0 Coil: Continuous duty molded Class A. Minimum Operating Current: amps. 5.03

2 Specifications (English units) 2/2 VALVES, NORMALLY CLOSED, with NBR Disc Operating Pressure Differential (psi) Pipe Orifice Air-Inert Gas Brass Body Stainless Steel Body Cv Flow Factor Min. Max. Max. Fluid and Ambient Temp. F Catalog Number Catalog Number 1/ 1/ WPIS8262A WSIS8262A /8 5/ WPIS8223A /2 3/ WPIS8223A WSIS8223A /2 VALVES Pipe Orifice Cv Flow Factor Pressure to Cylinder to Cylinder Operating Pressure Differential (psi) UNIVERSAL OPERATION (Pressure at port 1 or 2) with NBR Disc Air-Inert Gas Brass Body Exhaust Min. Max. Max. Fluid and Ambient Temp. F Catalog Number Stainless Steel Body Catalog Number 1/ 1/ WPIS831A300 ➃ 1 WSIS831A301 2 NORMALLY CLOSED (Closed when de-energized) with NBR Diaphragm 1/ 5/ ➅ WPIS8316A301 ➂ 3 WSIS8316A381V ➄ 3 3/8 5/ ➅ WPIS8316A302 ➂ 3 WSIS8316A382V ➄ 3 3/8 5/8 ➅ WPIS8316A303 ➂ 3A - - 1/2 5/8 ➅ WPIS8316A30 ➂ 3A WSIS8316A38V ➄ 3A 3/ 11/ WPIS8316A37 ➂ WPIS8316A33 ➂ UNIVERSAL OPERATION (Normally Closed or Normally Open) "Quick Exhaust" with CR Diaphragm and NBR Disc 1/ ➁ WPIS8317A307 ➀ 6 WSIS8317A308 ➀ 7 /2 VALVES, with NBR Disc and Seal 1/ 1/ WPIS835A301 ➀➂ 8 WSIS835A381 ➀➂ 8 /2 VALVES, Brass Body with NBR Disc Single Solenoid Dual Solenoid 1/ 1/ WPIS83A370 ➀➂ 9 WPIS83A3 ➂ 12 3/8 3/ WPIS83A372 ➀➂ 11 WPIS83A380 ➂ 10 1/2 3/ WPIS83A37 ➀➂ 11 WPIS83A382 ➂ 10 3/ 3/ WPIS83A376 ➀➂ 13 WPIS83A35 ➂ 1 1 3/ WPIS83A378 ➀➂ 13 WPIS83A356 ➂ 1 Notes: ➀ There are two exhaust flows in the exhaust mode (pilot and main). The pilot exhaust must be connected to the main exhaust when the air or inert gas cannot be exhausted to atmosphere. ➁ For Quick Exhaust valves, pressure port is 1/16", exhaust port is 1/". ➂ IMPORTANT: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. ➃ Available in 5 station N.C. Manifold. ➄ Diaphragm and main disc FKM only (pilot is low-temperature NBR). ➅ Zero minimum when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph with dimensional drawings for auxiliary pressure vs. mainline pressure. Minimum 15 psi Operating Pressure Differential when selection gasket is in the internal position. 5.0

3 Specifications (Metric units) 2/2 VALVES, NORMALLY CLOSED, with NBR Disc Pipe Orifice (mm) Kv Flow Factor (m3/h) Operating Pressure Differential (bar) Air-Inert Gas Brass Body Stainless Steel Body Min. Max. Max. Fluid and Ambient Temp. C Catalog Number 1/ WPIS8262A WSIS8262A / WPIS8223A / WPIS8223A WSIS8223A /2 VALVES Kv Flow Factor (m3/h) Operating Pressure Differential (bar) Air-Inert Gas Brass Body Stainless Steel Body Pipe Orifice Pressure to Cylinder UNIVERSAL OPERATION (Pressure at port 1 or 2) with NBR Disc Cylinder to Max. Fluid and Exhaust Min. Max. Ambient Temp. C Catalog Number Catalog Number 1/ WPIS831A300 ➃ 1 WSIS831A301 2 NORMALLY CLOSED (Closed when de-energized) with NBR Diaphragm 1/ ➅ WPIS8316A301 ➂ 3 WSIS8316A381V ➄ 3 3/ ➅ WPIS8316A302 ➂ 3 WSIS8316A382V ➄ 3 3/ ➅ WPIS8316A303 ➂ 3A - - 1/ ➅ WPIS8316A30 ➂ 3A WSIS8316A38V ➄ 3A 3/ WPIS8316A37 ➂ WPIS8316A33 ➂ UNIVERSAL OPERATION (Normally Closed or Normally Open) "Quick Exhaust" with CR Diaphragm and NBR Disc 1/ ➁ WPIS8317A307 ➀ 6 WSIS8317A308➀ 7 /2 VALVES, with NBR Disc and Seal 1/ WPIS835A301 ➀➂ 8 WSIS835A381 ➀➂ 8 /2 VALVES, Brass Body with NBR Disc Single Solenoid Dual Solenoid 1/ WPIS83A370 ➀➂ 9 WPIS83A3 ➂ 12 3/ WPIS83A372 ➀➂ 11 WPIS83A380 ➂ 10 1/ WPIS83A37 ➀➂ 11 WPIS83A382 ➂ 10 3/ WPIS83A376 ➀➂ 13 WPIS83A35 ➂ WPIS83A378 ➀➂ 13 WPIS83A356 ➂ 1 Notes: ➀ There are two exhaust flows in the exhaust mode (pilot and main). The pilot exhaust must be connected to the main exhaust when the air or inert gas cannot be exhausted to atmosphere. ➁ For Quick Exhaust valves, pressure port is 1/16", exhaust port is 1/". ➂ IMPORTANT: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. ➃ Available in 5 station N.C. Manifold. ➄ Diaphragm and main disc FKM only (pilot is low-temperature NBR). ➅ Zero minimum when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph on next page for auxiliary pressure vs. mainline pressure. Minimum 1 bar Operating Pressure Differential when selection gasket is in the internal position. 5.05

4 Ref. 1, 2 MAINLINE PRESSURE vs. PILOT LINE PRESSURE WHEN SELECTION GASKET IS IN EXTERNAL POSITION PILOT LINE PRESSURE (psi) MAINLINE PRESSURE (psi) 5.06

5 Ref. 3A Ref

6 A B C H K L M N P R W ins. X 1.78 X mm X 5 X ins mm Ref., 5 Ref. 6,

7 Ref. 8 D E F G H J K L N P W X Y Z Exhaust Pipe 9 ins. Ø /8 mm Ø /8 10 ins. Ø /2 mm Ø /2 11 ins. Ø /2 mm Ø /2 12 ins. Ø /8 mm Ø /8 13 ins. Ø mm Ø ins. Ø mm Ø Ref. 9, 10, 11, 12, 13,

8 Ref. 15 Ref. 16 Ref

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

SPCH/ Blowing block

SPCH/ Blowing block > > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Pneumatic pressure switch 20DD

Pneumatic pressure switch 20DD Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better

More information

Pilot Check Valve: Metal Body Type

Pilot Check Valve: Metal Body Type INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not

More information

2/2-Way Proportional Valve (motor-driven)

2/2-Way Proportional Valve (motor-driven) 2/2-Way Proportional Valve (motor-driven) Type 3280 can be combined with Seat valve with stepper motor - actuator isolated from flow path Excellent range (1:100) Low power consumption Fast response Orifice

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System

Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System PART 1: GENERAL 1.1 SCOPE A. This section describes the specifications of a bubbler system. B. The following information shall be described

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Pressure Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL File # MH 668 CSA Certified CSA C. No. LR File # 07 FM Approved Class 0, 0 File # J.I. Y9A9.AF Commonwealth of Massachusetts

More information

Pressure Switch for gas and air GGAO-A4

Pressure Switch for gas and air GGAO-A4 Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

The Ins and Outs of I/P Transducers

The Ins and Outs of I/P Transducers The Ins and Outs of I/P Transducers By Mark B. Levine, ControlAir Inc. General description I/P transducers are versatile instruments that use an electrical control signal to proportionally regulate gas

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

I/P Transducer Positioner Module

I/P Transducer Positioner Module I/P Transducer Positioner Module VRC P/N: 7958032 Installation, Operation and Maintenance Instructions 2.09 [53.1] 1.30 [32.9] 2.97 [75.5] 0.78 [19.8] 0.18 [4.4] 1.42 [36.1] n.18 MOUNTING HOLES (2) PLACES

More information

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI GP1 & GP2 Electropneumatic Regulators FOR PRESSURE CONTROL TO 1, PSI GP1 & GP2 Functional Description The GP series control valve is an electronic pressure regulator designed to precisely control the pressure

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Pressure switch for gas and air

Pressure switch for gas and air Pressure switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF GXX_A4

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

QBS Electronic Pressure Regulator

QBS Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBS stainless steel series is an electronically controlled pressure regulator. The QBS controls the pressure on its output port

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

Desde1963. Válvulas Pilotadas. Proveedor Integral. la Industria

Desde1963. Válvulas Pilotadas. Proveedor Integral. la Industria esde96 Válvulas Pilotadas Proveedor Integral de Por Soluciones Aire para la Industria Otras válvulas de proceso Cuerpos de Bronce, hierro fundido y conexión bridada, para completar la gama de soluciones.

More information

ellison sensors international

ellison sensors international PR3900 HAZARDOUS AREA PRESSURE TRANSMITTER ATEX CERTIFIED AND ALL EQUIVALENTS FOR HAZARDOUS AREAS: ZONE 0 GAS GROUP IIC, TEMPERATURE CLASS T4 AND ZONE 20 DUST PROTECTION BY INTRINSIC SAFETY TO EEXIA IIC

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Smooth Vent Valve XVD. Series

Smooth Vent Valve XVD. Series Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Valvex Valves for Mining Applications

Valvex Valves for Mining Applications Valvex Valves for Mining pplications roven technology The Electronic Drive Systems product group at Voith Turbo GmbH & Co. KG develops and produces explosion-proof Valvex solenoid valves and valve assemblies.

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I

More information

North American Pressure Switches

North American Pressure Switches Combustion North American Pressure Switches Bulletin 8757 Pressure switches are used with Automatic Shutoff Valves or Solenoid Valves to interrupt fuel flow in the event of fuel or air failure. They are

More information

Smooth Vent Valve. XVD Series

Smooth Vent Valve. XVD Series Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2. Introduction 1 Safety instructions 2 SITRANS Pressure transmitter SITRANS P, Z series for gauge and absolute pressure 7MF1564 Description 3 Assembly and connection 4 Technical data 5 Dimensional drawings

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800 KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm ort connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

2/2-way proportional valve

2/2-way proportional valve 2/2-way proportional valve High sensitivity Type can be combined with 0... 16 bar DN 0.8... 4 mm 1/8, 1/4 or sub-base EEx approvals optional Type 8605 Digital control electronics Cable plug version Type

More information

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked

More information

VALVES ISO 5599/1, SERIES IPV-ISV

VALVES ISO 5599/1, SERIES IPV-ISV VALVES ISO 99/1, SERIES IPV-ISV The assembly surface dimensions of ISO1 and ISO2 valves are to ISO99-1. They are available in the -way versions with 2 and 3 positions and with pneumatic or solenoid actuation.

More information

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators 61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally

More information

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3

More information

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series Safety Shutoff Valves /6 Series /6 Series Normally closed safety shutoff valve with the following approvals. UL Listed UL 49 File # MH16 CSA Certified ANSI Z1.1 CSA 6. Marked C/I File # LR 111 FM Approved

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Solenoid Valves used in Safety Instrumented Systems

Solenoid Valves used in Safety Instrumented Systems I&M V9629R1 Solenoid Valves used in Safety Instrumented Systems Operating Manual in accordance with IEC 61508 ASCO Valves Page 1 of 7 Table of Contents 1 Introduction...3 1.1 Terms and Abbreviations...3

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION The QB3 is a closed loop pressure regulator consisting of two solenoid valves, internal pressure transducer, and electronic controls mounted to an integrated

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

Jamieson Equipment Company 5314 Palmero Court Buford, GA

Jamieson Equipment Company 5314 Palmero Court Buford, GA CONTENTS GENERAL INDUSTRIAL CONTROL VALVES...Page 3 HOW TO ORDER GOYEN MANUFACTURED VALVES...Page 4 Direct Lift...Page 5 Pilot Operated - Air, Water and Light Oil...Page 6 Pilot Operated Ô- Air or Gas...Page

More information

Pilot valves for pilot operated servo valves

Pilot valves for pilot operated servo valves Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)

More information

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits

More information

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each

More information

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2 The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control

More information

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 Issue: 9 22 nd March 2013 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate

More information

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines to open against high differential pressure, e.g. after a hot gas defrost

More information

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Z, Y, and X PURGE INDICATORS / CONTROLLERS PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories

More information

Nugget 120 V14 Series

Nugget 120 V14 Series Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus

More information

Nugget 120 V14 Series

Nugget 120 V14 Series Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),

More information

Tapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment

Tapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment Electropneumatic Positioner Sturdy, simple, reliable design High gain pilot valve Built in gauge ports Tapped exhaust port Easy to add on Feedback Unit F5 Simple calibration, external zero adjustment Bright

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

PRESSURE SWITCHES Bulletin 8757

PRESSURE SWITCHES Bulletin 8757 PRESSURE SWITCHES Bulletin 8757 September 2013 Pressure switches are used with Automatic Shutoff Valves or solenoid valves to interrupt fuel fl ow in the event of fuel or air failure. They are also used

More information

Solenoid valve type EVR for Hydrocarbons

Solenoid valve type EVR for Hydrocarbons MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valve type EVR for Hydrocarbons EVR for Hydrocarbons is a direct or servo operated solenoid valve especially designed for liquid, suction, and

More information

NEW TYPE M PRESSURE RELIEF DEVICE

NEW TYPE M PRESSURE RELIEF DEVICE NEW TYPE M PRESSURE RELIEF DEVICE M PRESSURE RELIEF DEVICE ACCORDING TO EN 50216-5/A2 PATENTED 2 PRESSURE RELIEF DEVICE TYPE 50 M Section A-A 170 139 Transformer tank F 41.5 3 ø48.3 ø166 A P.R.D. TAG A

More information

GEMS SENSORS & CONTROLS

GEMS SENSORS & CONTROLS GEMS SENSORS & CONTROLS OPERATING & INSTALLATION INSTRUCTIONS 31XX / 32XX SERIES PLEASE READ CAREFULLY BEFORE INSTALLING Part Number: 560550-0076 Issue: E INTRODUCTION Series 3100/3200 high output pressure

More information

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas. February 2018 Description These 2-wire (loop-powered) I/P transmitters accept a current signal (such as 4-20mA) from a DCS, PLC or PC-based control system. They convert the current signal to a pneumatic

More information

Propor tional Re lief Valve s

Propor tional Re lief Valve s www.swagelok.com Propor tional Re lief Valve s R Series Liquid or gas service Set pressures from 10 to 6000 psig (0.68 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections Proportional Relief Valves

More information

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control. Document No. CAN7E-P MFB LX Series Modulating Control Valve Description Valves with magnetic actuator for modulating capacity control of refrigeration units and for heat recovery. Features Quick positioning

More information

HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR DEH SERIES

HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR DEH SERIES HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR PASSION TO PERFORM Filter elements are efficient only if their dirt holding capacity is fully exploited. This is achieved by using filter housings equipped

More information

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive

More information

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines for the opening against high differential pressure, e.g. after hot gas

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

ED 701 Hygenic Pressure Transmitter

ED 701 Hygenic Pressure Transmitter ED 701 Hygenic Pressure Transmitter Hygienic process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response time < 25 ms (Option

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated

More information

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability > > Modular design - Maxseal valves > > able terminations inside coil housing

More information