model 8317CTFP FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS AXION MSR Freeze Protected Shower and Eye/Face Wash

Size: px
Start display at page:

Download "model 8317CTFP FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS AXION MSR Freeze Protected Shower and Eye/Face Wash"

Transcription

1 model 8317TFP XION MS Freeze Protected Shower and ye/face Wash FTUS & NFITS ONSTUTION 1-1/4" Schedule 40 Stainless Steel pipe stanchion along with powder-coated cast-iron 9" (22.9 cm) diameter floor flange provide an unsurpassed durability in a long lasting product. ONSTUTION 3/4" (1.9 cm) insulation and S plastic jacket prevent freezing down to temperature levels as low as -30 F (-34.4 ) to maintain optimal functioning conditions. QULITY ONTOL ntire unit is pre-built and pressure tested to ensure a leak free installation. VLVS utomatic thermal actuator bleed valve opens when internal water temperature drops below 35 F (1.7 ) and will not close until temperature reaches 42 F (5.6 ) so the unit is protected against freezing. rass eye/face wash and shower ball valves are equipped with stainless steel ball and stem. TMPTU ONTOL 120V thermostatically controlled heat traced cable provides the energy needed to keep the combination shower and eye/face wash at an optimal temperature. SHOW H XION MS S plastic drench showerhead uses a hydrodynamic design to give equal distribution of water throughout the entire footprint of flow. Y/F WSH XION MS eye/face wash head (patent pending) uses an inverted directional laminar flow to sweep contaminants away from the vulnerable nasal cavity. OPTIONS Test Tag: SP170 is a green waterproof test card with space for date and initials of inspector. Used to record weekly testing of emergency equipment. Large Shower/yewash Sign: Model SP178LG large vertical universal combination emergency shower and eyewash sign. Size: 18" x 24" (45.7 x 61 cm). XION MS Showerhead: Model SP829SS, XION MS stainless steel drench showerhead with integral 20 gpm (75.7 L) flow control. Thermostatic Mixing Valve: Model 9201 XION mergency Tempering Valve thermostatically mixes hot and cold water to provide a safe fluid supply for emergency showers and eyewash equipment, with a flow rate of 31 gpm (117.3 L). To see all options for this model, visit SPIFITIONS Model 8317TFP freeze protected 120 V cable heated combination shower and eye/face wash shall include the XION MS hydrodynamic designed green S plastic 10-5/8" (26.9 cm) showerhead with integral self-regulating flow control, an XION MS eye/face wash head shall feature inverted directional laminar flow which achieves zero vertical velocity supplied by an integral flow control, chrome-plated brass shower and eyewash ball valves equipped with stainless steel ball and stem, separate ball valve activated hose spray, and automatic thermal actuator freeze protection bleed valve. Unit shall also include thermostatically controlled electric heat traced cable protected by 3/4" (1.9 cm) insulation and an S plastic green jacket that prevents freezing down to ambient temperatures of -30 F, powder-coated cast-iron 9" (22.9 cm) diameter floor flange, universal sign, 1-1/4" IPS supply, and rated lass 1, iv 2, Group, &. (lass I, IV I is available as a special option) PPLITIONS Where the eyes, face, or body of any person may be exposed to injurious or corrosive materials, suitable facilities for quick drenching or flushing of the eyes, face, and body shall be provided within the work area for immediate emergency use. Unit is ideal for areas where temperature may fluctuate down to freezing levels as low as -30 F ( ) mergency eye/face wash facilities and deluge showers shall be in unobstructed and accessible locations that require no more than 10 seconds for the injured person to reach.model 8317TFP is certified by S to meet the NSI Z358.1 Standard for mergency yewash and Shower quipment. Model is S electrical certified, TYP 4. (Nema 4 equivalent) 1455 Kleppe Lane :: Sparks, NV :: p :: f :: e. info@hawsco.com :: :: 10 June, 2015 ISLIM: ontinued product improvements make specifications subject to change without notice. heck for the latest product information and updates.

2 43 1/4" 1098mm 3 3/4" NPT JUNTION OX MOUNTING LOTION FO OPTIONL LIGHT 36-1/2" 927mm POW ONNTION 6 3/4" 171mm MOUNTING LOTION FO OPTIONL 1-1/4" IPS SUPPLY UNION (INLT) TOP SUPPLY SHOWN. S STP 2 OF TH POU IN TH OPTION & MINTNN MNUL ( 2) TO ONVT TO OTTOM SUPPLY UNIT. 1 of 4 NH HOS TIVTION VLV SSMLY 20-1/2" 521mm IMPOTNT SUPPLY MUST HT T N INSULT 85-1/2" 2172mm MOVL S JKT 30 Ø9" Ø229mm Ø3/8" 3X Ø10mm 95-1/2" 2426mm 90-1/2" 2299mm 7" 178mm Ø8" Ø203mm /4" 1708mm NH HOS 41-3/4" 1060mm NOTS: 1. IMNSIONS MY VY Y ± 1/2 INH [13mm]. FLOO LIN 2. TO OMPLY WITH NSI Z FO MGNY YWSH O Y/F WSH N SHOW QUIPMNT: - UNIT SHLL INSTLL IN ON WITH MNUFTU'S INSTUTIONS N PTL PLUMING PTIS. - YWSH O Y/F WSH SHLL POSITION WITH NOZZLS NOT LSS THN 83.8 M (33 IN.) N NO GT THN M (45 IN.) FOM SUF ON WHIH US STNS N 15.3 M (6 IN.) MINIMUM FOM WLL O NST OSTUTION. - SHOW SHLL POSITION SO THT SHOW H IS NOT LSS THN M (82 IN.) NO MO THN M (96 IN.) FOM SUF ON WHIH US STNS. - SHOW SPY PTTN SHLL HV MINIMUM IMT OF 50.8 M (20 IN.) T M (60 IN.) OV SUF ON WHIH US STNS, N NT OF SPY PTTN SHLL LOT T LST 40.6 M (16 IN.) FOM NY OSTUTION. 3. O NOT US GUL PIP SLNT. IF NSSY US OW ONING 832 SLNT PLING 5 SMLL S ON TH ML THS, JUST OV TH FIST TH. (NOTS ONTINU ON SHT 2 OF 4.) 6" 152mm 14" 355mm 6-3/4" 171mm NOT: PULL O N HNL NOT SSML. OINTTION OF HNL MUST IN UP POSITION WHN FULLY LOS N PULL O INST IN HOL SHOWN. SP158 FZ POTTION VLV (S NOTS ON SHTS 2 & 3 FO INSTUTIONS.) -MIL: HWS@HWSO.OM WSIT: N NO. VIS P Y: N: 4921 FV WN: T: HK'.: 8317TFP(120V)/ 8317TFP.220V TM 03/29/ FV 10/21/14 SL: 1/20 WING TYP: SIZ: SHT 1 OF Haws orporation - ll ights eserved. HWS and other trademarks used in these materials are the exclusive property of Haws orporation.

3 NOTS: (ONTINU FOM SHT 1 OF 4) 4. FZ POTTION VLV INSTUTIONS: INSTLL VLV SU-SSMLY INTO FML STION OF UNION N TIGHTN WT-TIGHT. FOM HT T L OUN VLV N PLUG, PPLY 2X L-TIS TO HT T L, S SHOWN, NSUING THT HT T L IS PSS FIMLY GINST SIS OF VLV (PUSH NY LOOS HT T L K INSI JKT THOUGH U GOMMT). TIM XSS L-TI STPPING. SLI INN TU W/ PLUGG N OV VLV WITH HSIV SM FING OTTOM N NON-PLUGG N OF TU UTT UP GINST UNION SUF. MOV 2X HSIV TP FOM SM N SQUZ HSIV SMS TOGTH OUN VLV. PPLY 2X L-TIS TO TU, IN PPOXIMT LOTIONS SHOWN. TIM XSS L-TI STPPING. 2 OF 4 (NOTS ONTINU ON SHT 3 OF 4) U GOMMT FML STION OF UNION (PT OF SHOW UNIT) ML STION OF UNION (PT OF VLV SU-SSY) HT T L L-TI, 15" / PN JKT SUF (S SHT 3.) L-TI, 15" / PN INN TU W/ PLUGG N PLUGG N HSIV SM VLV, FZ (NO UNION) SP158 ONNTO UNION SUF SP158 VLV SHOWN ONNT TO OTTOM UNION FO FN ONLY. VLV N INSTLL T TOP O OTTOM. -MIL: HWS@HWSO.OM WSIT: N NO. VIS P Y: 4632 N: 4921 HM WN: T: HK'.: 8317TFP(120V) / 8317TFP.220V VW 12/2/ FV 10/21/14 SL: N WING TYP: SIZ: SHT 2 OF Haws orporation - ll ights eserved. HWS and other trademarks used in these materials are the exclusive property of Haws orporation.

4 NOTS: (ONTINU FOM SHT 2 OF 4) 5. FZ POTTION VLV INSTUTIONS (ONTINU): WP OUT TU OV INN TU NPSULT VLV WITH HSIV SM OINT PPNIUL TO SM OF INN TU. PUSH OUT TU UP GINST JKT SUF. WHN TU IS MOUNT FIMLY GINST JKT SUF, SQUZ TU T ONNTO SUH THT NIPPL PUSHS THOUGH OUT TU WLL. (PUSHING ONNTO THOUGH WLL WILL XTU YLINIL PLUG OF TUING TO K F. IS PLUG.) PUSH TU OWN VN FUTH SO THT HOL IN TU STTHS OUN HXGONL OSS OF ONNTO. SQUZ OUT TU TIGHT UNTIL HSIV SMS LOS NOUGH TO SL. MOV POTTIV TP N SL SMS. 3 OF 4 TO NSU POP INSULTION OF UNION; TH MUST NO SP TWN OUT TU N JKT SUF (S SHT 2 FO SUF LLOUT). THFO, SLI TWO PLS, TOP SI N OTTOM SI, OMPLTLY THOUGH OUT TU TO LNGTH QUL TO PTH OF TIM SL. FO SLI TU OUN TIM SL N PUSH TU TIGHTLY GINST JKT, S SHOWN. PPLY 2X L-TI H, N 2X L-TI STP, TO TU, IN PPOXIMT LOTIONS SHOWN. TIM XSS STPPING. TIM SL SLI TU STION (TOP SI) STP, 2-P L-TI, 20" L H, 2-P L-TI / PN JKT/TU INTSTION OUT TU INN TU INSULTION SM PPNIUL HSIV SM ONNTO SLI TU STION (OTTOM SI) SP158 VLV SHOWN ONNT TO OTTOM UNION FO FN ONLY. VLV N INSTLL T TOP O OTTOM. -MIL: HWS@HWSO.OM WSIT: N NO. VIS P Y: 4632 N: 4921 HM WN: T: HK'.: 8317TFP(120V) / 8317TFP.220V VW 12/2/ FV 10/21/14 SL: N WING TYP: SIZ: SHT 3 OF Haws orporation - ll ights eserved. HWS and other trademarks used in these materials are the exclusive property of Haws orporation.

5 WIING TO INIT POW ON WIING TO INIT THMOSTT ON GOUN TO JUNTION OX 4 of 4 POW IN GOUN GN LK WHIT (120V)/ (220V) 120 V FO MOL 8317TFP 220 V FO MOL 8317TFP.220V TMINL LOK SHIL (OPTIONL) LIGHT THMOSTT HT T L (8317TFP ONLY SUPPOTS TWO OPTIONS T TIM) -MIL: HWS@HWSO.OM WSIT: N NO. VIS P Y: N: 4921 FV WN: T: HK'.: 8317TFP(120V)/ 8317TFP.220V TM 03/29/ FV 10/21/14 SL: N WING TYP: SIZ: SHT 4 OF Haws orporation - ll ights eserved. HWS and other trademarks used in these materials are the exclusive property of Haws orporation.

model 8317CTFP.220V FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS AXION MSR Freeze Protected Shower and Eye/Face Wash

model 8317CTFP.220V FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS AXION MSR Freeze Protected Shower and Eye/Face Wash model 8317TFP.220V XION MS Freeze Protected Shower and ye/face Wash FTUS & NFITS ONSTUTION 1-1/4" Schedule 40 Stainless Steel pipe stanchion along with powder-coated cast-iron 9" (22.9 cm) diameter floor

More information

Design Requirements for Eyewash and Safety Shower Units

Design Requirements for Eyewash and Safety Shower Units Design Requirements for Eyewash and Safety Shower Units Application: Eyewash Stations must be provided in the following areas. Laboratories Plumbed emergency eyewash equipment shall be installed in every

More information

Model TWBS.SH Tempered Water Blending System

Model TWBS.SH Tempered Water Blending System INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 455 Kleppe Lane Sparks, NV 8943-6467 (775) 359-472 Fax (775) 359-7424 HAWS AG Bachweg 3 CH-340 Burgdorf Switzerland Haws Mfg. Pte Lt. 2A Sungei Kadet

More information

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces

More information

Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA

Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) Top or Bottom Supply General Area Table of Contents Pre-Installation Information... 2-3 Components...4 Supplies

More information

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH Installation, Operating & Maintenance Instructions EEE180 EEE210 EFE360 EFE390 ENBE180 ENBE210 ENBE360 ENBE390 I00011_Apr 18 NOTE: THIS DOCUMENT IS TO BE

More information

D A N D E BATTERY BOX ASSEMBLY

D A N D E BATTERY BOX ASSEMBLY NOTS:. TTRY OX SSMLY ONSISTS O TWO INTIL SSMLIS 2. OTH MOUNT TO TH QUTORIL PLT ON TH +Z SI. SSM IS MOUNT ON TH +X SI 4. SSM 2 IS MOUNT ON TH -X SI 5 7 5 6 4 RVISIONS RVISION RVISION HNG T R PS2. INITIL

More information

Parts List Recessed Laboratory Units

Parts List Recessed Laboratory Units Recessed Laboratory Units tem Part Number escription P470-021L FS-Plus Spray ead P450-048 10 ia. Stainless Steel Shower ead P450-062 P450-016 10 ia. Recessed Flanged Stainless Steel Shower ead 8 ia. hrome

More information

Model Portable Eyewash

Model Portable Eyewash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 7601.37 Portable Eyewash

More information

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER Installation, Operating & Maintenance Instructions EW1050 I00232_Mar 2016 NOTE: THIS DOCUMENT IS TO BE LEFT ONSITE WITH FACILITY MANAGER AFTER INSTALLATION

More information

Installation. S19-300T (top supply) S19-300B (bottom supply)

Installation. S19-300T (top supply) S19-300B (bottom supply) Installation S19-300T (top supply) S19-300B (bottom supply) Heat Trace Combination Drench Shower and Eyewash Unit Class 1, Div. 1, Groups C & D (includes 120 V and 220/240 V versions) Table of Contents

More information

Parts List Recessed Laboratory Units

Parts List Recessed Laboratory Units tem Part Number escription P470-021L FS-Plus Spray ead P450-048 10 ia. Stainless Steel Shower ead P450-062 10 ia. Recessed Flanged Stainless Steel Shower ead 320-08 1 PS Stainless Steel Street lbow 310-08S

More information

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance Document Authority: EHS Coordinator Document Custodian: EH&S Coordinator Effective Date: 09.01.15 Issuing Dept: College

More information

gpphighpressure.com (417) BALL VALVES *Dimensions are subject to change and are considered reference.

gpphighpressure.com (417) BALL VALVES *Dimensions are subject to change and are considered reference. LL VLVS 51 *imensions are subject to change and are considered reference. 2 1 TURS & NITS O PP LL VLVS Trunnion style ball valves w/positive shut-off in 10,000-15,000-psi (689-104-179 bar) esigned for

More information

Model 9201E Tempered Water Blending System

Model 9201E Tempered Water Blending System INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9201E Tempered Water Blending

More information

8320 AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER

8320 AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER www.pnr.co.uk spraynozzles@pnr.co.uk +44(0)1527 579 066 8320 AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER 1 1/4"G 1 1/4"G 20,4 kg No CH Z535.1 AXION MSR eye / facewash head (SP65) Strainer SP509

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

ANSI / ISEA Z Compliance Checklist

ANSI / ISEA Z Compliance Checklist ANSI / ISEA Z358.1-2014 Compliance Checklist INTRODUCTION The selection of emergency eyewash and shower equipment is often a complicated process. In addition to addressing design and engineering issues,

More information

EMERGENCY EYEWASH STATIONS & SAFETY SHOWERS GUIDELINES

EMERGENCY EYEWASH STATIONS & SAFETY SHOWERS GUIDELINES EMERGENCY EYEWASH STATIONS & SAFETY SHOWERS GUIDELINES PURPOSE The Guidelines for Emergency Eyewash Stations and Safety Showers were developed by the Occupational Health & Safety Office in support of the

More information

ANSI / ISEA Z Compliance Checklist

ANSI / ISEA Z Compliance Checklist ANSI / ISEA Z358.1-2014 Compliance Checklist ANSI / ISEA Z358.1 Compliance Checklist introduction The selection of emergency eyewash and shower equipment is often a complicated process. In addition to

More information

Laboratory Safety Guideline Emergency Eyewash and Safety Showers

Laboratory Safety Guideline Emergency Eyewash and Safety Showers Introduction The purpose of this program is to ensure that all safety eyewashes and showers supply clean, potable water and are in proper working order. This program describes procedures for emergency

More information

ANSI Z Compliance Checklist

ANSI Z Compliance Checklist ANSI Z358.1 Compliance Checklist 660 North Union Street (312) 733-2626 P Compliance Checklist Introduction The selection of emergency eye wash and shower equipment is often a complicated process. In addition

More information

6301 TYPE CAST IRON SAFETY VALVES

6301 TYPE CAST IRON SAFETY VALVES Pressure (bar) 6301 TYPE CAST IRON SAFETY VALVES FEATURES The 6301 type safety valve is a device designed to protect installations against possible overpressure. It operates automatically and closes when

More information

Emergency Eyewash & Shower Testing Program

Emergency Eyewash & Shower Testing Program Emergency Eyewash & Shower Testing Program Summary: The purpose of this program is to ensure that safety eyewashes and showers supply clean, potable water and are in proper working order. This program

More information

WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED

WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED Installation, Operating & Maintenance Instructions EEE120 EFE300 I00097_Oct 17 NOTE: THIS DOCUMENT IS TO BE LEFT ONSITE WITH FACILITY MANAGER AFTER

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

Water Temperature Control - Groups of Fixtures

Water Temperature Control - Groups of Fixtures Digital - Outlook ASSE 1070 Certified Up to six outlets from a single valve Programmable timed flow (independent for each outlet) On/Off or preset timed flow control with either touch or no touch sensors

More information

Field Adjustable Pressure Reducing (URFA)

Field Adjustable Pressure Reducing (URFA) IL JUSTL PRSSUR RUING 10-1 ield djustable Pressure Reducing (UR) lkhart s UR valve is a true pressure reducing valve, operated automatically by inner hydraulic controls. While the valves are preset at

More information

Pump Assembly. 25 Ton Jack. Air Kit. Emerson PN. Hyd Kit. Emerson PN. Air Kit ITEM NO.

Pump Assembly. 25 Ton Jack. Air Kit. Emerson PN. Hyd Kit. Emerson PN. Air Kit ITEM NO. 2 4 ITM NO. ir Hyd SRIPTION QTY. 2-0P Pump ody 2 2-02P Piston Spring 2-0P Piston ssembly 4 2-04P Piston O-Ring 2-0P ir Piston Rod O-Ring 6 2-06P ir Motor lock 7 2-07P ir Motor lock O-Ring 8 2-08P ir Motor

More information

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3 Worldwide Contacts www.tyco-fire.com Model B-1 Pipe Line Strainer General Description The Model B-1 Pipe Line Strainers (Ref. Figures 1 and 2) are designed for installation in the water supply connection

More information

CAST IRON SAFETY VALVE TYPE 6301

CAST IRON SAFETY VALVE TYPE 6301 CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

BTV. Internally threaded 2-way control valve. Flow characteristics. Function Internally threaded 2-way control valve The valves are designed for control of hot, cold or glycol-mixed water in heating and ventilation systems. They are pressure balanced (from DN20-50, not DN15) and

More information

ACCREDITED. Technical specifications series

ACCREDITED. Technical specifications series nti-pollution check valves 0-0-0-0-0 series REITE ISO 0 FM LEFFI 000/ G replaces dp 000/0G Function The anti-pollution check valve is a protective plumbing device capable of preventing the backflow of

More information

Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE.

Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE. Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE www.wilsontaylor.co INTRODUCTION Wilson Taylor Asia Pacific, headquartered in Singapore with a subsidiary based in Hong Kong and a representative

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER . ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces

More information

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000 Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre Revision Date: 5/17/2016 Page: 1 of 13 Health & Safety has developed the emergency eyewash & safety shower equipment procedure which will be implemented in 3 phases over the next four years. Phase 1 will

More information

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment ANSI Z358.1 Compliance Checklist Compliance Checklist Introduction The selection of emergency eye wash and shower equipment is often a complicated

More information

Technical Data Sheet T 2025

Technical Data Sheet T 2025 Self-operated emperature Regulators emperature Regulator ype 4 Valve closes when the temperature rises. emperature Regulator ype 4u Valve opens when the temperature rises. Balanced single-seated globe

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

Function. size 1-¼ inch: 9-¾" size 1-½ inch: 11-¼" size 2 inch: 12-¾" A A A A A/96A A/99A

Function. size 1-¼ inch: 9-¾ size 1-½ inch: 11-¼ size 2 inch: 12-¾ A A A A A/96A A/99A Hydro separator CLEI 0076/6 N CCREDITED Replaces 0076/4 N ISO 900 No. 000 ISO 900 M 2654 unction The Caleffi 548 and N hydraulic separator creates a zone with a low pressure loss, which enables connected

More information

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700 Series e700 ADA compliant 1016 listed B125 Certified Self-contained cartridge installs in minutes Cartridge retrofits into all Powers Series 900 Pressure Balancing Valves - Model 3 Integral checkstops

More information

sil mla water meter valves

sil mla water meter valves WTR SRIS QULITY Y TRITION sil mla water meter valves THNIL SHT 05/2017 IP09020 SOP SRVI ONITIONS SIL ML series are metallic ball valves manually operated that, due to their design are intended to be used

More information

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE February 9, 1998 Foam 101a A BLADDER TANK WITH 1. DESCRIPTION A Wet Pipe Bladder Tank Foam/Water System is a standard wet pipe automatic sprinkler system capable of discharging a foam/water solution automatically

More information

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection February 9, 1998 Foam 201a 1. DESCRIPTION A Deluge Bladder Tank Foam/Water System is a standard deluge system capable of discharging a foam/water solution automatically through open sprinklers, spray nozzles,

More information

Pressure reduction controller (PN 16, 25, 40)

Pressure reduction controller (PN 16, 25, 40) Pressure reduction controller (PN 16, 25, 40) AFD / VFG 2( - for water AFD / VFGS 2 - for steam Description The controller has a control valve, an actuator with one control diaphragm and a spring for pressure

More information

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data Technical Services: Tel: (800) 381-312 / Fax: (800) 71-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Model B-1 Pipe Line Strainer 3,, 6 & 8 Inch (DN80, DN100, DN150

More information

RCP5W-RA Series. www. r o b o c y lind e r. d e. Dust-/Splash-/Water-proof RoboCylinder Rod Type with Battery-less Absolute Encoder

RCP5W-RA Series. www. r o b o c y lind e r. d e. Dust-/Splash-/Water-proof RoboCylinder Rod Type with Battery-less Absolute Encoder Product Data Sheets RCPW-RA RoboCylinder Brochure Extract GB Dust-/Splash-/Water-proof RoboCylinder Rod with Battery-less Absolute Encoder RCPW-RA Series www. r o b o c y lind e r. d e Specification Table

More information

Wet pipe low flow foam/water system

Wet pipe low flow foam/water system December 6, 2010 Foam 14a 1. The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with Viking supplied foam concentrates. This system consists of a standard

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

EMERGENCY EYEWASH & SHOWERS

EMERGENCY EYEWASH & SHOWERS INTRODUCTION The purpose of this is to ensure that safety eyewashes and showers supply clean, potable water and are in proper working order. This program defines guidelines for inspection, testing and

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE Page 1 of 10 1. DESCRIPTION The Viking Model F-1 Deluge Valve is a quick opening, differential diaphragm and flood valve with one moving mechanism. The Deluge Valve is used to control water flow in Deluge

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

Anti-flood device Model B-1

Anti-flood device Model B-1 December 4, 2009 Dry Systems 123a 1. DESCRIPTION The Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

BERMAD Waterworks. Level Control Valve with Bi-Level Vertical Float. 700 Series Model B. Features and Benefits. Major Additional Features

BERMAD Waterworks. Level Control Valve with Bi-Level Vertical Float. 700 Series Model B. Features and Benefits. Major Additional Features Level ontrol Valve with i-level Vertical Float Reservoir filling Very low supply-pressure Low noise generation Energy cost-critical systems Systems with poor water quality Reservoir outlet Distribution

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Aquadue Duplo Page 1

Aquadue Duplo Page 1 Connt th timr to th tp. quu Duplo Pg 1 Usr mnul TIME DY STRT STOP CNCEL TIME DY lik! STRT STOP CNCEL TIME DY For quu Duplo (p/n): 8410 Opn th timr unit y prssing th two uttons on th sis, n fit 9V lklin

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA Q= C. Table 1 - Specifications September 25, 2013 Pressure Regulation 537a 1. Description The Model B-3 Pilot Operated Pressure Control Valve is a factory assembled unit. The unit consists of a Model J-2 Halar coated Flow Control Valve,

More information

Aquor House Hydrant V2

Aquor House Hydrant V2 Aquor House Hydrant V2 IN-WALL OUTDOOR FAUCET SYSTEM FLUSH-MOUNT QUICK-CONNECT SELF-DRAINING ANTI-SIPHON NON-FREEZE VBH-SERIES AQUOR HOUSE HYDRANT V2: WALL HYDRANT / FREEZELESS SILLCOCK Freezeless sillcock

More information

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION Page 1 of 6 1. DESCRIPTION The Model B-1 Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET condition,

More information

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 257a. September 16, 2013 September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking

More information

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998 February 9, 1998 Foam 301a A BLADDE TANK WITH HYDAULICALLY ACTUATED DELUGE CONCENTATE CONTOL VALVE 1. DESCIPTION A Preaction Bladder Tank Foam/Water System is a standard preaction system capable of discharging

More information

EYE WASH STATIONS & SAFETY SHOWERS GUIDELINES

EYE WASH STATIONS & SAFETY SHOWERS GUIDELINES EYE WASH STATIONS & SAFETY SHOWERS GUIDELINES PURPOSE These guidelines support the Health and Safety Policy and provide assistance on the application of Australian Standard 4775-2007 eye wash and shower

More information

Safety Shut-off Valve SSV

Safety Shut-off Valve SSV Safety Shut-off Valve SSV 8200-8300 < Accurate operation < Compact design < Easy maintenance Applications The safety shut-off valve is designed for use in gas distribution, and pressure regulation systems.

More information

WaterSource Heat Pump Hose Kit Performance Specification-Summary

WaterSource Heat Pump Hose Kit Performance Specification-Summary WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo

More information

8122H AXION Drench / Safety Shower

8122H AXION Drench / Safety Shower www.pnr.co.uk spraynozzles@pnr.co.uk +44(0)57 579 066 8H AXION Drench / Safety Shower "G 3.8 kg No CH Z358. Horizontal wall installation AXION MSR Greens ABS shower head (SP89) Stay open valve (SP60) Universal

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information

Pressure reducing valves

Pressure reducing valves Pressure reducing valves series 60-6 - 6-66 cert. n 000 ISO 9001 06/01 G Replaces 06/97 G Function Pressure reducers are devices which, when installed on a water system, reduce and stabilise the pressure

More information

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure Bacteria/Legionella Protection Is Lower Better? The Other Side to the Coin. It s truly a double-edged sword.

More information

Emergency Shower & Eyewash. Training Guide

Emergency Shower & Eyewash. Training Guide Emergency Shower & Eyewash Training Guide No matter how many precautions employees take, accidents sometimes happen. In these situations quick action is essential, and if the incident involves a hazardous

More information

Magnetic Level Gauges

Magnetic Level Gauges Bulletin B 03 04 Magnetic Level Gauges Remote Reading Systems Magnetic Level Switches Magnetic level gauges OPERATING PRINCIPLE The operation of the magnetic level gauge is based on some elementary physical

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

BERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve.

BERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve. Basic Valve IR- Yflow Basic Valve Te BERMAD basic Model IR- Yflow diapragm actuated, ydraulically operated valve is at te leading edge of control valve design. It combines simple and reliable construction

More information

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity) for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity This is a Pilot operated pressure reducing valve. It is suitable to install in the steam lines with the

More information

Variable displacement vane pump (with mechanical pressure compensator)

Variable displacement vane pump (with mechanical pressure compensator) Variable displacement vane (with mechanical pressure compensator) PVS-Type Key Features: Rotation: Right (viewed from shaft end) Mounting flanges: 4-hole flange (UNI ISO 319/2) onnections: GS SP (UNI ISO

More information

Torque Tube TB300 Digital Transmitters

Torque Tube TB300 Digital Transmitters Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional

More information

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level. DN 0 to 1000 - Serie K3 0 On-Off levels float control valve, closing at high level and opening at low level. Functions Prevents overflowing and closes at a constant and adjustable high level. Remains closed

More information

sensible sophistication

sensible sophistication d e s i g n e r f a u c e t s & a c c e s s o r i e s sensible sophistication A rare collection of artistic expressions for the distinctive home environment. Mirabelle is a fusion of form, craftsmanship

More information

Integral type Differential pressure flowmeter VNT Series

Integral type Differential pressure flowmeter VNT Series Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.

More information

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20 table of contents kitchen accessories Air Gaps.............3 Basket Strainers.........3 Disposal Flanges....... 3-4 Faucet Hole Covers....... 4 Soap & Lotion Dispensers.... 4 Water Dispensers........ 4

More information

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate December 6, 2010 Foam 21a 1. Description With Multiple Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple deluge foam risers can be supplied from a single foam concentrate source. Where a bladder

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

V43 Pressure Actuated Water Regulating Valve

V43 Pressure Actuated Water Regulating Valve FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled

More information

Standard Specifications

Standard Specifications NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.

More information

OBSOLETE. Wet pipe low flow manifold system

OBSOLETE. Wet pipe low flow manifold system June 1, 2008 Foam 15a 1. Description Multiple risers can be supplied from a single proportioning device. A riser manifold is installed with various riser types and sizes that are to supply foam solution

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Data sheet Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications.

More information

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013 October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve

More information