model 8317CTFP.220V FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS AXION MSR Freeze Protected Shower and Eye/Face Wash

Size: px
Start display at page:

Download "model 8317CTFP.220V FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS AXION MSR Freeze Protected Shower and Eye/Face Wash"

Transcription

1 model 8317TFP.220V XION MS Freeze Protected Shower and ye/face Wash FTUS & NFITS ONSTUTION 1-1/4" Schedule 40 Stainless Steel pipe stanchion along with powder-coated cast-iron 9" (22.9 cm) diameter floor flange provide an unsurpassed durability in a long lasting product. ONSTUTION 3/4" (1.9 cm) insulation and S plastic jacket prevent freezing down to temperature levels as low as -30 F (-34.4 ) to maintain optimal functioning conditions. QULITY ONTOL ntire unit is pre-built and pressure tested to ensure a leak free installation. VLVS utomatic thermal actuator bleed valve opens when internal water temperature drops below 35 F (1.7 ) and will not close until temperature reaches 42 F (5.6 ) so the unit is protected against freezing. rass eye/face wash and shower ball valves are equipped with stainless steel ball and stem. TMPTU ONTOL 220V thermostatically controlled heat traced cable provides the energy needed to keep the combination shower and eye/face wash at an optimal temperature. SHOWH XION MS S plastic drench showerhead uses a hydrodynamic design to give equal distribution of water throughout the entire footprint of flow. Y/F WSH XION MS eye/face wash head (patent pending) uses an inverted directional laminar flow to sweep contaminants away from the vulnerable nasal cavity. OPTIONS Thermostatic Mixing Valve: Model 9201 XION mergency Tempering Valve thermostatically mixes hot and cold water to provide a safe fluid supply for emergency showers and eyewash equipment, with a flow rate of 31 gpm (117.3 L). NSI Shower and yewash Testing Kit: Model 9011 NSI compliance test kit. XION MS Showerhead: Model SP829SS, XION MS stainless steel drench showerhead with integral 20 gpm (75.7 L) flow control. Thermostatic Mixing Valve: Model 9201H Lead-free XION mergency Tempering Valve thermostatically mixes hot and cold water to provide a safe fluid supply for emergency showers and eyewash equipment, with a flow rate of 31 gpm (117.3 L). For more information, visit or call (888) SPIFITIONS Model 8317TFP.220V freeze protected 220 V cable heated combination shower and eye/face wash shall include the XION MS hydrodynamic designed green S plastic 10-5/8" (26.9 cm) showerhead with integral self-regulating 20 gpm flow control, an XION MS eye/face wash head that features inverted directional laminar flow which achieves Zero Vertical Velocity supplied by an integral 4 gpm flow control, brass shower and eyewash ball valves equipped with stainless steel ball and stem, separate ball valve activated hose spray, and automatic thermal actuator freeze protection bleed valve. Unit shall also include thermostatically controlled electric heat traced cable protected by 3/4" (1.9 cm) insulation and an S plastic green jacket that prevents freezing down to ambient temperatures of -30 F (-34.4 ), powder-coated cast-iron 9" (22.9 cm) diameter floor flange, universal sign, 1-1/4" NPT supply, and rated lass I, ivision 2, Group, and, with a 1.25 amp draw. (lass I, IV I is available as a special option) PPLITIONS Where the eyes, face, or body of any person may be exposed to injurious or corrosive materials, suitable facilities for quick drenching or flushing of the eyes, face, and body shall be provided within the work area for immediate emergency use. Unit is ideal for areas where temperature may fluctuate down to freezing levels as low as -30 F ( ) mergency eye/face wash facilities and deluge showers shall be in unobstructed and accessible locations that require no more than 10 seconds for the injured person to reach.model 8317TFP.220V is certified by S to meet the NSI Z358.1 Standard for mergency yewash and Shower quipment. Model is S electrical certified, TYP 4. (Nema 4 equivalent) 1455 Kleppe Lane :: Sparks, NV :: p :: f :: e. info@hawsco.com :: :: 22 July, 20 ISLIM: ontinued product improvements make specifications subject to change without notice. heck for the latest product information and updates.

2 THIS OUMNT IS TU N OT T TIM OF PULITION. ONTINU POUT IMPOVMNTS MK SPIFITIONS N MSUMNTS SUJT TO HNG WITHOUT NOTI. 43 1/4" 1098mm 3 3/4" NPT JUNTION OX MOUNTING LOTION FO OPTIONL LIGHT 36-1/2" 927mm POW ONNTION 6 3/4" 171mm MOUNTING LOTION FO OPTIONL INITO LIGHT 1-1/4" IPS SUPPLY UNION (INLT) TOP SUPPLY SHOWN. S STP 2 OF TH POU IN TH OPTION & MINTNN MNUL (PG 2) TO ONVT TO OTTOM SUPPLY UNIT. NH HOS TIVTION VLV SSMLY 20-1/2" 521mm S TIL IMPOTNT SUPPLY MUST HT T N INSULT 85-1/2" 2172mm MOVL S JKT 7" 178mm 30 Ø9" Ø229mm Ø3/8" 3X Ø10mm 95-1/2" 2426mm 90-1/2" 2299mm Ø8" Ø203mm MOUNTING TIL /4" 1708mm 33"-53" 838mm-1346mm FLOW PTTN NH HOS 41-3/4" 1060mm NOTS: 6" 152mm FLOO LIN S MOUNTING TIL 6-3/4" 171mm TIL NOT: PULL O N HNL NOT SSML. OINTTION OF HNL MUST IN UP POSITION WHN FULLY LOS N PULL O INST IN HOL SHOWN. 1. WHN INSTLLING THIS UNIT, LOL, STT, O FL OS SHOUL H TO FO IMNSIONS (LOTIONS), WST N SUPPLY QUIMNTS OTH THN SHOWN. 2. TO OMPLY WITH NSI Z FO MGNY YWSH O Y/F WSH: YWSH O Y/F WSH SHLL POSITION SUH THT FLUSHING FLUI PTTN IS NOT LSS THN 33" (838mm) N NO GT THN 53" (1346mm) FOM SUF ON WHIH US STNS; N 6.0" (153mm) MINIMUM FOM WLL O NST OSTUTION. 3 O NOT US GUL PIP SLNT. IF NSSY US OW ONING 832 SLNT PLING FIV SMLL S ON ML THS, JUST OV TH FIST TH. 4. IMNSIONS MY VY Y ±1/2" (13 mm). (NOTS ONTINU ON SHT 2.) 14" 355mm SP158 FZ POTTION VLV (S NOTS ON SHTS 2 & 3 FO INSTUTIONS.) 1455 KLPP LN SPKS, NV (775) FX (775) MIL: HWS@HWSO.OM WSIT: N NO. VIS P Y: MOL(S) PT NUM 4632 N: 5241 VW WN: T: HK'.: 8317TFP(120V) / 8317TFP.220V VISION TM 3/29/05 VW PPOV: T: FV 11/23/17 SL: N WING TYP: SIZ: SHT 1 OF Haws orporation - ll ights eserved. HWS and other trademarks used in these materials are the exclusive property of Haws orporation

3 THIS OUMNT IS TU N OT T TIM OF PULITION. ONTINU POUT IMPOVMNTS MK SPIFITIONS N MSUMNTS SUJT TO HNG WITHOUT NOTI. NOTS: (ONTINU FOM SHT 1 OF 4) 4. FZ POTTION VLV INSTUTIONS: INSTLL VLV SU-SSMLY INTO FML STION OF UNION N TIGHTN WT-TIGHT. FOM HT T L OUN VLV N PLUG, PPLY 2X L-TIS TO HT T L, S SHOWN, NSUING THT HT T L IS PSS FIMLY GINST SIS OF VLV (PUSH NY LOOS HT T L K INSI JKT THOUGH U GOMMT). TIM XSS L-TI STPPING. SLI INN TU W/ PLUGG N OV VLV WITH HSIV SM FING OTTOM N NON-PLUGG N OF TU UTT UP GINST UNION SUF. MOV 2X HSIV TP FOM SM N SQUZ HSIV SMS TOGTH OUN VLV. PPLY 2X L-TIS TO TU, IN PPOXIMT LOTIONS SHOWN. TIM XSS L-TI STPPING. (NOTS ONTINU ON SHT 3 OF 4) U GOMMT FML STION OF UNION (PT OF SHOW UNIT) ML STION OF UNION (PT OF VLV SU-SSY) HT T L L-TI, 15" / PN JKT SUF (S SHT 3.) L-TI, 15" / PN INN TU W/ PLUGG N PLUGG N HSIV SM VLV, FZ (NO UNION) SP158 ONNTO UNION SUF SP158 VLV SHOWN ONNT TO OTTOM UNION FO FN ONLY. VLV N INSTLL T TOP O OTTOM KLPP LN SPKS, NV (775) FX (775) MIL: HWS@HWSO.OM WSIT: N NO. VIS P Y: MOL(S) PT NUM 4632 N: 5241 VW WN: T: HK'.: 8317TFP(120V) / 8317TFP.220V VISION VW 12/2/12 VW PPOV: T: FV 11/23/17 SL: N WING TYP: SIZ: SHT 2 OF Haws orporation - ll ights eserved. HWS and other trademarks used in these materials are the exclusive property of Haws orporation

4 THIS OUMNT IS TU N OT T TIM OF PULITION. ONTINU POUT IMPOVMNTS MK SPIFITIONS N MSUMNTS SUJT TO HNG WITHOUT NOTI. NOTS: (ONTINU FOM SHT 2 OF 4) 5. FZ POTTION VLV INSTUTIONS (ONTINU): WP OUT TU OV INN TU NPSULT VLV WITH HSIV SM OINT PPNIUL TO SM OF INN TU. PUSH OUT TU UP GINST JKT SUF. WHN TU IS MOUNT FIMLY GINST JKT SUF, SQUZ TU T ONNTO SUH THT NIPPL PUSHS THOUGH OUT TU WLL. (PUSHING ONNTO THOUGH WLL WILL XTU YLINIL PLUG OF TUING TO K F. IS PLUG.) PUSH TU OWN VN FUTH SO THT HOL IN TU STTHS OUN HXGONL OSS OF ONNTO. SQUZ OUT TU TIGHT UNTIL HSIV SMS LOS NOUGH TO SL. MOV POTTIV TP N SL SMS. TO NSU POP INSULTION OF UNION; TH MUST NO SP TWN OUT TU N JKT SUF (S SHT 2 FO SUF LLOUT). THFO, SLI TWO PLS, TOP SI N OTTOM SI, OMPLTLY THOUGH OUT TU TO LNGTH QUL TO PTH OF TIM SL. FO SLI TU OUN TIM SL N PUSH TU TIGHTLY GINST JKT, S SHOWN. PPLY 2X L-TI H, N 2X L-TI STP, TO TU, IN PPOXIMT LOTIONS SHOWN. TIM XSS STPPING. TIM SL SLI TU STION (TOP SI) STP, 2-P L-TI, 20" L H, 2-P L-TI / PN JKT/TU INTSTION OUT TU INN TU INSULTION SM PPNIUL HSIV SM ONNTO SLI TU STION (OTTOM SI) SP158 VLV SHOWN ONNT TO OTTOM UNION FO FN ONLY. VLV N INSTLL T TOP O OTTOM KLPP LN SPKS, NV (775) FX (775) MIL: HWS@HWSO.OM WSIT: N NO. VIS P Y: MOL(S) PT NUM 4632 N: 5241 VW WN: T: HK'.: 8317TFP(120V) / 8317TFP.220V VISION VW 12/2/12 VW PPOV: T: FV 11/23/17 SL: N WING TYP: SIZ: SHT 3 OF Haws orporation - ll ights eserved. HWS and other trademarks used in these materials are the exclusive property of Haws orporation

5 THIS OUMNT IS TU N OT T TIM OF PULITION. ONTINU POUT IMPOVMNTS MK SPIFITIONS N MSUMNTS SUJT TO HNG WITHOUT NOTI. (OPTIONL) INITO LIGHT WIING TO INIT POW ON INITO LIGHT (OPTIONL) WIING TO INIT THMOSTT ON GOUN TO JUNTION OX POW IN GOUN GN LK WHIT (120V)/ (220V) 120 V FO MOL 8317TFP 220 V FO MOL 8317TFP.220V (OPTIONL) LIGHT THMOSTT TMINL LOK SHIL HT T L LTIL SHMTI (8317TFP ONLY SUPPOTS TWO OPTIONS T TIM) 1455 KLPP LN SPKS, NV (775) FX (775) MIL: HWS@HWSO.OM WSIT: N NO. VIS P Y: MOL(S) PT NUM 4632 N: 5241 VW WN: T: HK'.: 8317TFP(120V) / 8317TFP.220V VISION TM 3/29/05 VW PPOV: T: FV 11/23/17 SL: N WING TYP: SIZ: SHT 4 OF Haws orporation - ll ights eserved. HWS and other trademarks used in these materials are the exclusive property of Haws orporation

model 8317CTFP FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS AXION MSR Freeze Protected Shower and Eye/Face Wash

model 8317CTFP FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS AXION MSR Freeze Protected Shower and Eye/Face Wash model 8317TFP XION MS Freeze Protected Shower and ye/face Wash FTUS & NFITS ONSTUTION 1-1/4" Schedule 40 Stainless Steel pipe stanchion along with powder-coated cast-iron 9" (22.9 cm) diameter floor flange

More information

Design Requirements for Eyewash and Safety Shower Units

Design Requirements for Eyewash and Safety Shower Units Design Requirements for Eyewash and Safety Shower Units Application: Eyewash Stations must be provided in the following areas. Laboratories Plumbed emergency eyewash equipment shall be installed in every

More information

D A N D E BATTERY BOX ASSEMBLY

D A N D E BATTERY BOX ASSEMBLY NOTS:. TTRY OX SSMLY ONSISTS O TWO INTIL SSMLIS 2. OTH MOUNT TO TH QUTORIL PLT ON TH +Z SI. SSM IS MOUNT ON TH +X SI 4. SSM 2 IS MOUNT ON TH -X SI 5 7 5 6 4 RVISIONS RVISION RVISION HNG T R PS2. INITIL

More information

Model TWBS.SH Tempered Water Blending System

Model TWBS.SH Tempered Water Blending System INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 455 Kleppe Lane Sparks, NV 8943-6467 (775) 359-472 Fax (775) 359-7424 HAWS AG Bachweg 3 CH-340 Burgdorf Switzerland Haws Mfg. Pte Lt. 2A Sungei Kadet

More information

Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA

Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) Top or Bottom Supply General Area Table of Contents Pre-Installation Information... 2-3 Components...4 Supplies

More information

Parts List Recessed Laboratory Units

Parts List Recessed Laboratory Units Recessed Laboratory Units tem Part Number escription P470-021L FS-Plus Spray ead P450-048 10 ia. Stainless Steel Shower ead P450-062 P450-016 10 ia. Recessed Flanged Stainless Steel Shower ead 8 ia. hrome

More information

Installation. S19-300T (top supply) S19-300B (bottom supply)

Installation. S19-300T (top supply) S19-300B (bottom supply) Installation S19-300T (top supply) S19-300B (bottom supply) Heat Trace Combination Drench Shower and Eyewash Unit Class 1, Div. 1, Groups C & D (includes 120 V and 220/240 V versions) Table of Contents

More information

Parts List Recessed Laboratory Units

Parts List Recessed Laboratory Units tem Part Number escription P470-021L FS-Plus Spray ead P450-048 10 ia. Stainless Steel Shower ead P450-062 10 ia. Recessed Flanged Stainless Steel Shower ead 320-08 1 PS Stainless Steel Street lbow 310-08S

More information

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces

More information

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH Installation, Operating & Maintenance Instructions EEE180 EEE210 EFE360 EFE390 ENBE180 ENBE210 ENBE360 ENBE390 I00011_Apr 18 NOTE: THIS DOCUMENT IS TO BE

More information

Model Portable Eyewash

Model Portable Eyewash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 7601.37 Portable Eyewash

More information

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER Installation, Operating & Maintenance Instructions EW1050 I00232_Mar 2016 NOTE: THIS DOCUMENT IS TO BE LEFT ONSITE WITH FACILITY MANAGER AFTER INSTALLATION

More information

ANSI / ISEA Z Compliance Checklist

ANSI / ISEA Z Compliance Checklist ANSI / ISEA Z358.1-2014 Compliance Checklist INTRODUCTION The selection of emergency eyewash and shower equipment is often a complicated process. In addition to addressing design and engineering issues,

More information

Model 9201E Tempered Water Blending System

Model 9201E Tempered Water Blending System INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9201E Tempered Water Blending

More information

ANSI Z Compliance Checklist

ANSI Z Compliance Checklist ANSI Z358.1 Compliance Checklist 660 North Union Street (312) 733-2626 P Compliance Checklist Introduction The selection of emergency eye wash and shower equipment is often a complicated process. In addition

More information

sil mla water meter valves

sil mla water meter valves WTR SRIS QULITY Y TRITION sil mla water meter valves THNIL SHT 05/2017 IP09020 SOP SRVI ONITIONS SIL ML series are metallic ball valves manually operated that, due to their design are intended to be used

More information

8320 AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER

8320 AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER www.pnr.co.uk spraynozzles@pnr.co.uk +44(0)1527 579 066 8320 AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER 1 1/4"G 1 1/4"G 20,4 kg No CH Z535.1 AXION MSR eye / facewash head (SP65) Strainer SP509

More information

6301 TYPE CAST IRON SAFETY VALVES

6301 TYPE CAST IRON SAFETY VALVES Pressure (bar) 6301 TYPE CAST IRON SAFETY VALVES FEATURES The 6301 type safety valve is a device designed to protect installations against possible overpressure. It operates automatically and closes when

More information

ANSI / ISEA Z Compliance Checklist

ANSI / ISEA Z Compliance Checklist ANSI / ISEA Z358.1-2014 Compliance Checklist ANSI / ISEA Z358.1 Compliance Checklist introduction The selection of emergency eyewash and shower equipment is often a complicated process. In addition to

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

Water Temperature Control - Groups of Fixtures

Water Temperature Control - Groups of Fixtures Digital - Outlook ASSE 1070 Certified Up to six outlets from a single valve Programmable timed flow (independent for each outlet) On/Off or preset timed flow control with either touch or no touch sensors

More information

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance Document Authority: EHS Coordinator Document Custodian: EH&S Coordinator Effective Date: 09.01.15 Issuing Dept: College

More information

Aquadue Duplo Page 1

Aquadue Duplo Page 1 Connt th timr to th tp. quu Duplo Pg 1 Usr mnul TIME DY STRT STOP CNCEL TIME DY lik! STRT STOP CNCEL TIME DY For quu Duplo (p/n): 8410 Opn th timr unit y prssing th two uttons on th sis, n fit 9V lklin

More information

gpphighpressure.com (417) BALL VALVES *Dimensions are subject to change and are considered reference.

gpphighpressure.com (417) BALL VALVES *Dimensions are subject to change and are considered reference. LL VLVS 51 *imensions are subject to change and are considered reference. 2 1 TURS & NITS O PP LL VLVS Trunnion style ball valves w/positive shut-off in 10,000-15,000-psi (689-104-179 bar) esigned for

More information

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER . ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

EMERGENCY EYEWASH STATIONS & SAFETY SHOWERS GUIDELINES

EMERGENCY EYEWASH STATIONS & SAFETY SHOWERS GUIDELINES EMERGENCY EYEWASH STATIONS & SAFETY SHOWERS GUIDELINES PURPOSE The Guidelines for Emergency Eyewash Stations and Safety Showers were developed by the Occupational Health & Safety Office in support of the

More information

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

BTV. Internally threaded 2-way control valve. Flow characteristics. Function Internally threaded 2-way control valve The valves are designed for control of hot, cold or glycol-mixed water in heating and ventilation systems. They are pressure balanced (from DN20-50, not DN15) and

More information

Emergency Eyewash & Shower Testing Program

Emergency Eyewash & Shower Testing Program Emergency Eyewash & Shower Testing Program Summary: The purpose of this program is to ensure that safety eyewashes and showers supply clean, potable water and are in proper working order. This program

More information

WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED

WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED Installation, Operating & Maintenance Instructions EEE120 EFE300 I00097_Oct 17 NOTE: THIS DOCUMENT IS TO BE LEFT ONSITE WITH FACILITY MANAGER AFTER

More information

Laboratory Safety Guideline Emergency Eyewash and Safety Showers

Laboratory Safety Guideline Emergency Eyewash and Safety Showers Introduction The purpose of this program is to ensure that all safety eyewashes and showers supply clean, potable water and are in proper working order. This program describes procedures for emergency

More information

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3 Worldwide Contacts www.tyco-fire.com Model B-1 Pipe Line Strainer General Description The Model B-1 Pipe Line Strainers (Ref. Figures 1 and 2) are designed for installation in the water supply connection

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000 Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They

More information

ACCREDITED. Technical specifications series

ACCREDITED. Technical specifications series nti-pollution check valves 0-0-0-0-0 series REITE ISO 0 FM LEFFI 000/ G replaces dp 000/0G Function The anti-pollution check valve is a protective plumbing device capable of preventing the backflow of

More information

CAST IRON SAFETY VALVE TYPE 6301

CAST IRON SAFETY VALVE TYPE 6301 CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment ANSI Z358.1 Compliance Checklist Compliance Checklist Introduction The selection of emergency eye wash and shower equipment is often a complicated

More information

Field Adjustable Pressure Reducing (URFA)

Field Adjustable Pressure Reducing (URFA) IL JUSTL PRSSUR RUING 10-1 ield djustable Pressure Reducing (UR) lkhart s UR valve is a true pressure reducing valve, operated automatically by inner hydraulic controls. While the valves are preset at

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

BERMAD Waterworks. Level Control Valve with Bi-Level Vertical Float. 700 Series Model B. Features and Benefits. Major Additional Features

BERMAD Waterworks. Level Control Valve with Bi-Level Vertical Float. 700 Series Model B. Features and Benefits. Major Additional Features Level ontrol Valve with i-level Vertical Float Reservoir filling Very low supply-pressure Low noise generation Energy cost-critical systems Systems with poor water quality Reservoir outlet Distribution

More information

Technical Data Sheet T 2025

Technical Data Sheet T 2025 Self-operated emperature Regulators emperature Regulator ype 4 Valve closes when the temperature rises. emperature Regulator ype 4u Valve opens when the temperature rises. Balanced single-seated globe

More information

Mark 608. Gas Pressure Regulators. Pressure Regulators Mark 608 Gas Pressure Regulators SPECIFICATIONS (3/4-1-1/4 ) FEATURES 3/4-1-1/4

Mark 608. Gas Pressure Regulators. Pressure Regulators Mark 608 Gas Pressure Regulators SPECIFICATIONS (3/4-1-1/4 ) FEATURES 3/4-1-1/4 Mark Gas Pressure Regulators 3/4-1-1/4 The MK Gas Pressure Regulator is the ideal valve for low pressure gas regulation. The self-contained low pressure gas regulator is for use on tank blanketing, gas

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Data sheet Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications.

More information

Pump Assembly. 25 Ton Jack. Air Kit. Emerson PN. Hyd Kit. Emerson PN. Air Kit ITEM NO.

Pump Assembly. 25 Ton Jack. Air Kit. Emerson PN. Hyd Kit. Emerson PN. Air Kit ITEM NO. 2 4 ITM NO. ir Hyd SRIPTION QTY. 2-0P Pump ody 2 2-02P Piston Spring 2-0P Piston ssembly 4 2-04P Piston O-Ring 2-0P ir Piston Rod O-Ring 6 2-06P ir Motor lock 7 2-07P ir Motor lock O-Ring 8 2-08P ir Motor

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP

More information

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300.

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300. EVRM-NC EVRM-6NC Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300 delta-elektrogas.com www.solenoid-valve.world EE166-03/17 EVRM-NC EVRM-6NC Safety solenoid valves for gas Manual

More information

Pressure reduction controller (PN 16, 25, 40)

Pressure reduction controller (PN 16, 25, 40) Pressure reduction controller (PN 16, 25, 40) AFD / VFG 2( - for water AFD / VFGS 2 - for steam Description The controller has a control valve, an actuator with one control diaphragm and a spring for pressure

More information

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Data sheet Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Description VL 2 VL 3 VL 2 and VL 3 valves provide a quality, cost effective solution for most water and chilled applications.

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

VB-7211 Series. Application. Features. Applicable Literature. 1/2 to 1-1/4 Union End NPT Stem Up Open, Two-Way Valves General Instructions TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com VB-7211 Series 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions Application VB-7211 series stem

More information

V146 Series 2-Way Pressure-Actuated Water-Regulating Valves

V146 Series 2-Way Pressure-Actuated Water-Regulating Valves roduct/technical Bulletin V146 Issue Date November 20, 2002 V146 Series 2-Way ressure-actuated Water-Regulating s The V146 Series 2-Way ressure-actuated Water-Regulating s regulate water flow and control

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT

MURRAY-CALLOWAY EDC INDUSTRIAL DEVELOPMENT PHS: SHMTI SIGN - NOT OR ONSTRUTION T: 09..205 SHT INX SHT NUMR ISSU T esigner -03-04 SON LOOR PLN OI PLNS 09/5/5 09/2/5 GNRL G-000 G-00 OVR GNRL RQUIRMNTS RHITTURL -00-0 -02-05 -06-20 -30-302 -40-50 -60

More information

Wet pipe low flow foam/water system

Wet pipe low flow foam/water system December 6, 2010 Foam 14a 1. The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with Viking supplied foam concentrates. This system consists of a standard

More information

Function. size 1-¼ inch: 9-¾" size 1-½ inch: 11-¼" size 2 inch: 12-¾" A A A A A/96A A/99A

Function. size 1-¼ inch: 9-¾ size 1-½ inch: 11-¼ size 2 inch: 12-¾ A A A A A/96A A/99A Hydro separator CLEI 0076/6 N CCREDITED Replaces 0076/4 N ISO 900 No. 000 ISO 900 M 2654 unction The Caleffi 548 and N hydraulic separator creates a zone with a low pressure loss, which enables connected

More information

Aquor House Hydrant V2

Aquor House Hydrant V2 Aquor House Hydrant V2 IN-WALL OUTDOOR FAUCET SYSTEM FLUSH-MOUNT QUICK-CONNECT SELF-DRAINING ANTI-SIPHON NON-FREEZE VBH-SERIES AQUOR HOUSE HYDRANT V2: WALL HYDRANT / FREEZELESS SILLCOCK Freezeless sillcock

More information

V43 Pressure Actuated Water Regulating Valve

V43 Pressure Actuated Water Regulating Valve FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled

More information

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20 table of contents kitchen accessories Air Gaps.............3 Basket Strainers.........3 Disposal Flanges....... 3-4 Faucet Hole Covers....... 4 Soap & Lotion Dispensers.... 4 Water Dispensers........ 4

More information

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700 Series e700 ADA compliant 1016 listed B125 Certified Self-contained cartridge installs in minutes Cartridge retrofits into all Powers Series 900 Pressure Balancing Valves - Model 3 Integral checkstops

More information

Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE.

Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE. Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE www.wilsontaylor.co INTRODUCTION Wilson Taylor Asia Pacific, headquartered in Singapore with a subsidiary based in Hong Kong and a representative

More information

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate December 6, 2010 Foam 21a 1. Description With Multiple Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple deluge foam risers can be supplied from a single foam concentrate source. Where a bladder

More information

Pressure reducing valves

Pressure reducing valves Pressure reducing valves series 60-6 - 6-66 cert. n 000 ISO 9001 06/01 G Replaces 06/97 G Function Pressure reducers are devices which, when installed on a water system, reduce and stabilise the pressure

More information

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998 February 9, 1998 Foam 301a A BLADDE TANK WITH HYDAULICALLY ACTUATED DELUGE CONCENTATE CONTOL VALVE 1. DESCIPTION A Preaction Bladder Tank Foam/Water System is a standard preaction system capable of discharging

More information

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data Technical Services: Tel: (800) 381-312 / Fax: (800) 71-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Model B-1 Pipe Line Strainer 3,, 6 & 8 Inch (DN80, DN100, DN150

More information

RCP5W-RA Series. www. r o b o c y lind e r. d e. Dust-/Splash-/Water-proof RoboCylinder Rod Type with Battery-less Absolute Encoder

RCP5W-RA Series. www. r o b o c y lind e r. d e. Dust-/Splash-/Water-proof RoboCylinder Rod Type with Battery-less Absolute Encoder Product Data Sheets RCPW-RA RoboCylinder Brochure Extract GB Dust-/Splash-/Water-proof RoboCylinder Rod with Battery-less Absolute Encoder RCPW-RA Series www. r o b o c y lind e r. d e Specification Table

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE February 9, 1998 Foam 101a A BLADDER TANK WITH 1. DESCRIPTION A Wet Pipe Bladder Tank Foam/Water System is a standard wet pipe automatic sprinkler system capable of discharging a foam/water solution automatically

More information

VMR VMR-OTN VMR 6 bar

VMR VMR-OTN VMR 6 bar VMR VMR-OTN VMR 6 bar Safety solenoid valves for gas Fast opening and fast closing type DN8 DN150 delta-elektrogas.com EE161-03/17 VMR VMR-OTN VMR 6 bar Safety solenoid valves for gas Fast opening and

More information

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection February 9, 1998 Foam 201a 1. DESCRIPTION A Deluge Bladder Tank Foam/Water System is a standard deluge system capable of discharging a foam/water solution automatically through open sprinklers, spray nozzles,

More information

Safety Shut-off Valve SSV

Safety Shut-off Valve SSV Safety Shut-off Valve SSV 8200-8300 < Accurate operation < Compact design < Easy maintenance Applications The safety shut-off valve is designed for use in gas distribution, and pressure regulation systems.

More information

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level

More information

Anti-flood device Model B-1

Anti-flood device Model B-1 December 4, 2009 Dry Systems 123a 1. DESCRIPTION The Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET

More information

V311. Venta. Three-way Plug Valve, Flanged PN 16

V311. Venta. Three-way Plug Valve, Flanged PN 16 1 Three-way Plug Valve, Flanged PN 16 can be used in a wide range of applications, such as heating, cooling, air handling and domestic hot water systems. Soft EPDM seals provide tight shut off. The valve

More information

COMMERCIAL. MK Series High Performance Butterfly Valve Specifications. Hot Water, Chilled Water, Condenser Water, Steam

COMMERCIAL. MK Series High Performance Butterfly Valve Specifications. Hot Water, Chilled Water, Condenser Water, Steam OMMRIL MK Series igh Performance utterfly Submittal/Technical ata ray MK Series igh Performance utterfly Valves NSI lass 150 and 300 ray ontrols ommercial ivision 13788 West Road, Suite 200 ouston, Texas

More information

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre Revision Date: 5/17/2016 Page: 1 of 13 Health & Safety has developed the emergency eyewash & safety shower equipment procedure which will be implemented in 3 phases over the next four years. Phase 1 will

More information

BERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve.

BERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve. Basic Valve IR- Yflow Basic Valve Te BERMAD basic Model IR- Yflow diapragm actuated, ydraulically operated valve is at te leading edge of control valve design. It combines simple and reliable construction

More information

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION Page 1 of 6 1. DESCRIPTION The Model B-1 Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET condition,

More information

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate December 6, 2010 Foam 31a 1. Description With Multiple Pilot Pressure Regulating Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple pilot pressure regulating foam risers can be supplied from

More information

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity) for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity This is a Pilot operated pressure reducing valve. It is suitable to install in the steam lines with the

More information

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level. DN 0 to 1000 - Serie K3 0 On-Off levels float control valve, closing at high level and opening at low level. Functions Prevents overflowing and closes at a constant and adjustable high level. Remains closed

More information

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 257a. September 16, 2013 September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

10mm SHOWER PANEL SIZES 1000 & 1200 SIZES 500, 600, 700, 800 & 900 SIZES 1000 & 1200 OPTION 1 - PAGES 2-4 OPTION 2 - PAGES 2-5 OPTION 3 - PAGES 6-7

10mm SHOWER PANEL SIZES 1000 & 1200 SIZES 500, 600, 700, 800 & 900 SIZES 1000 & 1200 OPTION 1 - PAGES 2-4 OPTION 2 - PAGES 2-5 OPTION 3 - PAGES 6-7 SHOWER PANEL 785 / Issue / 5 SIZES 5, 6, 7, 8 & 9 SIZES & SIZES & OPTION - PAGES - OPTION - PAGES - 5 OPTION 3 - PAGES 6-7 Plese red these instrutions refully nd keep for future referene. Inorret fitting

More information

Standard Specifications

Standard Specifications NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.

More information

WaterSource Heat Pump Hose Kit Performance Specification-Summary

WaterSource Heat Pump Hose Kit Performance Specification-Summary WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo

More information

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Description Supply pressure Pressure range Connection Device Page max. bar bar thread Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4

More information

OBSOLETE. Wet pipe low flow manifold system

OBSOLETE. Wet pipe low flow manifold system June 1, 2008 Foam 15a 1. Description Multiple risers can be supplied from a single proportioning device. A riser manifold is installed with various riser types and sizes that are to supply foam solution

More information

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

VB-7213 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Stem Up Open, Two-Way Valves General Instructions VB-7213 Series 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions Application VB-7213 series single seat, stem up open, two-way valves control water from 20 to 281 F (-7 to 138 C)

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

INDUSTRIAL GAS SOLUTIONS. Cryogenic & Non-Cryogenic

INDUSTRIAL GAS SOLUTIONS. Cryogenic & Non-Cryogenic INDUSTRIAL GAS SOLUTIONS Cryogenic & Non-Cryogenic EN-2018 INDUSTRIAL GAS SOLUTIONS Since more than 50 years, MECA-INOX is a ball valve strategic partner of major chemistry and process industries for liquid

More information

THERM-O-MIX STATION/WWM TEMPERED WATER SUPPLY

THERM-O-MIX STATION/WWM TEMPERED WATER SUPPLY ISO9001 THERM-O-MIX STATION/WWM TEMPERED WATER SUPPLY Name: S/N: Date: V3 Diaphragm Valve V1 Mixing Valve 1 NPT Inlets V4 Final Water Temperature Control Valve 1-1/4 NPT Outlet Union ThermOmegaTech, Inc.

More information

Installation and commissioning instructions 255 series and 256 series

Installation and commissioning instructions 255 series and 256 series Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...

More information

UPGRADABLE PRESSURE BALANCE BAT/SOWER FITTING VOLUME AND TEMPERATURE CONTROL VALVE 1-5/8" TO 3-1/ ROUG VALVE OPTIONS 1/2" NPT 1/2" NOM or 1/2" NOM or

UPGRADABLE PRESSURE BALANCE BAT/SOWER FITTING VOLUME AND TEMPERATURE CONTROL VALVE 1-5/8 TO 3-1/ ROUG VALVE OPTIONS 1/2 NPT 1/2 NOM or 1/2 NOM or UPGRADABLE PRESSURE BALANCE BAT/SOWER FITTING VOLUME AND TEMPERATURE CONTROL VALVE MODEL NUMBER: R121 Valve Body Shown R121 Pressure Balance Rough Valve Body only inlets/outlets. LESS trim. Available s

More information