The Amsterdam Initiative against Malnutrition

Size: px
Start display at page:

Download "The Amsterdam Initiative against Malnutrition"

Transcription

1 INVITATION FOR BIDS LABORATORY SUPPLIES - BLESS AGRI FOOD LABORATORY ETHIOPIA The Quality Improvement Network is a public-private partnership project focusing on the improvement of food safety and quality in Ethiopia under the Amsterdam Initiative against Malnutrition (AIM). One of the key components is the scaling up and improvement of facilities of the Bless Agri Food Laboratory in Ethiopia. The project partners include The Global Alliance for Improved nutrition (GAIN), DSM, AkzoNobel and Intertek who collectively are providing in kind capacity building technical assistance to the project with the Government of the Netherlands providing financial assistance to support procurement of equipment and implementation of other activities Tenders are invited for the supply of laboratory equipment to Bless Agri Food Laboratory in Ethiopia. The bidding will be conducted in accordance with project requirements and other stipulations as set by the Netherlands Enterprise Agency which includes a market conformity test. The successful bidder will enter into a contract with Bless Agri Food Laboratory. The bidding is open to all companies with appropriate expertise in the supply, installation, training and providing after sales service for the equipment. 1 SCOPE OF GOODS Tenders are invited for the supply of equipment, reagents, accessories and other laboratories supplies. Full list of items and technical specifications are outlined in Annex I. 2 INSTRUCTIONS TO BIDDERS I. Prospective bidders are expected to confirm in writing of their intention to submit the bid by sending an to qualitynetwork@gainhealth.org II. Bidders may submit bid for the supply of all items or part of the items in Annex I but bidders are not allowed to submit alternative tenders. III. Bidders are expected to review all the requirements of the tender documents. Failure to comply will be at the bidders risk and may affect the evaluation of their submission. IV. Prospective bidders requiring clarification of any part of the tender documents may do so by sending an to qualitynetwork@gainhealth.org no later than 7 days before the closing date of the tender. V. Bidders must fully complete the Form of Tender (including maximum delivery time) and submit a proposal. Failure to fully complete and return these documents and information stated under Bidders Proposals will render the bid non compliant and it will be rejected. VI. All tenders will be arithmetically checked, any errors will be brought to the bidders attention. The rates supplied would be the basis for the arithmetic correction and would be the determining factor for any queries about the corrected price. Corrected prices must be agreed by the bidder. VII. Prior to the deadline for submission of bids, the buyer at their own initiative including clarifications requested by prospective bidders, reserves the right to amend the tender

2 documents. All prospective bidders who confirmed their intention to submit a bid will be notified in writing of amendments. VIII. The buyer reserves the right to extend the deadline for submission of bids at its own discretion or to afford prospective bidders reasonable time in response to any amendments that the buyer may make. IX. Bidders should be aware that by submitting a bid, they confirm that their proposals and quotations have been duly authorized by an appropriate person and acknowledge that they will be bound by the requirements of the tender. X. Bidders may amend or withdraw their tenders by written notification prior to the deadline for submission of tenders. No tender may be amended after this deadline. XI. The tender notice is only an invitation and the buyer is not bound to accept the lowest or any tenders and reserves the right to reject any or all tenders. XII. Bid documents in PDF format must be submitted to the following address: qualitynetwork@gainhealth.org by 12 August, All bids received will be acknowledged. The buyer will not be responsible for any s that have been lost, not been delivered by the closing time or where attached documents are corrupted. XIII. Payment will be by irrevocable Letter of Credit payable at sight. 3 BIDDERS PROPOSALS. All proposals, communication, correspondence, quotations and relevant documents shall be in English. Proposals shall comprise the following; a) Bidders experience and expertise in supplying similar goods including evidence of similar contracts within the last two years. b) Brochures, data sheets or other relevant documents for the items and clearly demonstrate that they meet the specifications outlined in Annex I. c) Warranty periods and terms should be clearly specified including the capability to install, train and provide after sales service in Ethiopia either directly or through an appointed service provider locally. Please refer to specifications for further guidance on warranties and training. d) Following installation, provision of all documents pertaining to the equipment and the attachments which form part of this tender to include, but not limited to, maintenance manuals, operation manuals, commissioning certificates and a comprehensive list of recommended spare parts. e) Pricing should be submitted FOB INCOTERMS. Pricing should be in Euro or US$. f) Discounts provided if any. g) Proposals including pricing must be valid for 90 days from the tender closing date.

3 4 TENDER FORM Tender Evaluation Committee Quality Improvement Network Project Procurement of Laboratory supplies for Bless Agri Foods Laboratory Re: Tender for the Laboratory Supplies Bless Agri Food Laboratory. We the undersigned undertake to supply and deliver the products as outlined in the above captioned project in accordance with product specifications as provided in the tender documents for the sum of: EUR/US$ (Words). If our tender is accepted, we undertake to complete the supply and deliver the goods within weeks from the date of receipt by us of the official award of contract or purchase order. We understand that we shall not be reimbursed for any cost that may have been incurred in compiling this tender. We confirm this tender shall remain valid for a period of 90 days from the date of the tender closing date. Name.. Signed Name of Firm. Address... Tel.. Fax Date

4 5 EVALUATION OF TENDER Evaluation Criteria The following evaluation criteria will be used to evaluate tenders received in response to this Invitation to Tender. Tenders must achieve a minimum score of 70% to be considered for award of contract. Bidders that fail to meet the above qualifying score will be rejected and not considered for award of contract. Price (30%) Bidders must complete the Tender Form and return this with their tender submission. The percentage for this criterion will be calculated proportionately in comparison to other price submissions from tenders. Warranty Length & Inclusiveness (10%) Bidders should provide in their tender the terms and conditions, and length of any warranty provided with the sale of the equipment. Marks will be awarded on the basis of warranty length and the comprehensiveness of coverage. The percentage for this criterion will be calculated in proportion to warranty submissions from other tenders. Technical Support / Training (before and after sales) (15%) The percentage for this criterion will be calculated proportionately to similar submissions from other tenders. Availability (Delivery Time) (15%) The percentage for this criterion will be calculated proportionately to similar submissions from other tenders. Technical Specifications (30%) Adherence to technical specification is paramount. However, consideration will be given to durability and enhanced safety features. Marks will be awarded depending on the degree of compliance with the technical specifications as compared with the other tenders. 6 TENDER CHECKLIST The following documents should be provided for a contractor s bid to be valid. Failure to provide any of the stated documents may result in the bid being considered non compliant and rejected: a) Completed proposal including price sheet providing the supplies that meet the required specification and other key requirements as provided under Bidders Proposals b) Completed and Signed Form of Tender. The Form of Tender document shall be Signed by a person legally authorized to bind the firm to a contract. The complete tender sum should be clearly written and included in the form of tender).

5 TECHNICAL SPECIFICATIONS ANNEX I HPLC SPECIFICATION PUMP Low pressure or high pressure binary mixing High precision dual plunger design With a flow rate ranging from 0.001ml to 5.0 ml/min or higher With a flow rate accuracy of ±1% or better With a flow rate precision of 0.1% RSD or better Maximum operating pressure up to 400 bar or higher Should have self-diagnostic and auto purge feature Should be capable of stand-alone operation and must have a leak sensor Should have a 4 channel low pressure solvent mixing capability Should have an automatic rinsing mechanism for cleaning of plunger Should come with maintenance kit, reservoir tray with 4 solvent bottles complete with fittings DIODE ARRAY DETECTOR With a wavelength ranging from 190 nm to 800 nm or higher With 512 diode elements or better With a wavelength accuracy of ± 1nm at 254nm and a wavelength precision of ± 0.1nm or better With a noise level of 0.6x10-5 AU/cm at 254 nm or better Scan rate 20Hz or more With a band width of 1.2 nm for high peak resolution A deuterium and Tungsten lamp should be available as light source for UV and visible wavelengths respectively Flow cell solvent way length 1cm or more, Flow cell volume 10µL or less, Should come with the appropriate flow cell for semi-preparative work Spare Deuterium lamp FLUORESCENCE DETECTOR Light source should be a Xenon lamp With a wavelength ranging from 200 nm to 750 nm With a spectral bandwidth of 20 nm With a wavelength accuracy of ± 2 nm or better With a wave length precision of ± 0.2 nm or better With a flow cell of 8 12 μl volume Must come with 3 spare fluorescent Xenon lamps REFRACTIVE INDEX DETECTOR With a refractive index ranging from 1 RIU to 1.75 RIU

6 With a noise level of less than 2.5 x 10-9 RIU Should have an automatic cell temperature controller up to 50 C or higher AUTOSAMPLER With injection volume ranging from 0.1 μl to 100 μl or better With a sample carryover of 0.005% or better With an injection volume accuracy of ±1% With an injection volume precision of 0.3% RSD Should be able to perform customized sequential analyses according to the conditions specified for each sample including pre-treatment, injection and analysis conditions. Should be capable of rinsing flow-line both before and after sampling Should have a leak sensor, automatic rack and vial recognition as safety feature Should come with 500 sample vials of 2 ml capacity complete with caps and septa along with racks COLUMN OVEN Should have forced air circulation for uniform temperature distribution Should accommodate at least 3 columns of 250 mm length Should have temperature regulation from ambient plus 10 o C to 80 o C or better Should come with a solvent leak sensor SYSTEM CONTROLLER Should function as a communication bus for all modules of HPLC system with data buffering capability DEGASSER Membrane degassing unit for 4 flow lines with a leak sensor as safety feature Maximum operating flow rate up to 10 ml/min per flow line COMPUTER SYSTEM AND SOFTWARE COMPUTER and PRINTER: Intel based, icore 5orabove, At least 8 GB RAM, 500 GB HDD or above, DVD/CD Writer, High Speed USB Ports, (at least 2 x USB 3.0) Network Card, 1Gbyte At least 22 LCD Monitor, Keyboard, Mouse, with all the necessary cables, Color Printer Compatible with the above Specifications LC-CCONTROL SOFTWARE: Compatible with Windows 7 Operation of the system should be easy and intuitive Should have single access point for system administration, data acquisition, post run analysis and long term data management

7 Should have a contextual online help function Auto start-up, auto shut-down, baseline stability auto judgment, auto validation, auto purge, etc. must be available from a touch of a button Allow for the reprocessing of analytical results after an analysis is complete A multipoint calibration curve calculation using the average value of each concentration should be possible Allow the user to report results in a variety of concentration formats The reporting format should be flexible and easy to use in any desired format Ability to convert instrument data sets to standard formats like MS-EXCEL, pdf Should have its own log files for complete audit trails Should have quality control and diagnostic features Should have an audio-visual multi-media CD-ROM for maintenance and troubleshooting, or other easy access features for maintenance and troubleshooting System suitability, System security as well as System check functions must be provided which comply with Good Laboratory Practice (GLP) and Regulatory Conformity INSTALLATION, TRAINING AND TROUBLESHOOTING INSTALLATION: The system should be installed and commissioned by a qualified service engineer from the supplier Trial tests (PT, SRM or QC Samples from a recognized supplier) should be carried out after installation and results should be comparable with the literature/accepted values For a good and timely technical support, the supplier must have a technical subsidiary of the supplier/manufacturer in Africa with easy access to fast technical support TRAINING: The supplier should provide on-site system overview and training on the operation and maintenance of the complete system provided by the supplier s application specialist following a successful system installation. The training must be sufficient enough to enable the operators with the knowledge to carry out the general daily operation and maintenance of the complete system Package should also include further training on the system and application3 to 6 months after a period of exposure time on the instrument (exact time to be scheduled by the laboratory) WARRANTY: At least 2 years warranty after the installation should be provided The complete system should be accompanied with a Declaration of Conformity Certificate System must be supplied with complete user manuals, service manuals, circuit diagrams, and circuit description, all in English language.

8 ADDITIONAL ACCESSORIES SPARES and CONSUMABLES UPS Full sets of spares and consumables (such as ferrules, tubing, fittings, adaptors, flow cell, guard columns, syringes, needles if any for sample injection, vials, caps, and septa) for 2 years of trouble free operation for the instrument and associated accessories A 5KVA Uninterrupted Power Supply (UPS) system with 1 hour backup from a standard manufacturer. The UPS specification can be changed accordingly with the requirements of the selected HPLC System and accessories COLUMNS 10 pieces of 150mm x 4.6 mm x 5 µm C-8 Reversed Phase Columns 10 pieces of 150mm x 4.6 mm x 5 µm C-18 Reversed Phase Columns 5 pieces of 300 mm x 4 (id) mm Carbohydrate Columns 5 pieces of 250 mm x 4.6 mm x 5 µm Amino Columns MAINTENANCE KIT Complete for normal servicing and repairing of the HPLC system

9 LC-MSMS SPECIFICATION TECHNICAL SPECIFICATIONS VACUM SYSTEM A robust high efficiency vacuum system with minimum maintenance and utility with low noise level and automatic vacuum lock system ION SOURCE Dual Atmospheric Pressure Ionization Sources (ESI and APCI) The ionization probes switching should be simple and tool free Should have capability for high solvent flow analysis Cleaning and maintenance must be simple and without breaking the vacuum MASS ANALYZER and DETECTOR Triple quadruple system having high standards of mechanical tolerance and minimum coefficient of thermal expansion to ensure highest mass stability Mass range should be m/z 50 to 2000 or better Scanning speed should be amu/s or more Mass resolution should be 0.5 amu or better Dynamic range must be more than or equal to 6 orders of magnitude High sensitivity for qualitative and quantitative analysis while maintaining high resolution and high speed scanning Detector must operate both in positive and negative ion mode and must be capable of switching polarity rapidly within one run and should be able to save the data of both modes in the same data file. Scan mode should include Full Scan, SIM, Product Ion Scan, Precursor Scan, Neutral Loss/Gain Scan, Multiple Reaction Monitoring (MRM) Scan, Information dependent acquisition system or equivalent scan mode of MRM to high sensitivity production scan for library conformation, and automated tuning LC SYSTEM 4-channel low pressure gradient or high pressure gradient pump with flow rate ranging from ml to 10 ml/min or more, pressure up to 1000 bar or more, and a flow precision of 0.01% or better A 4 channel degasser Thermostat auto-sampler capable of holding vials of 0.5 ml to 10 ml volumes, a sample injection volume range 0.1 μl to 50 μl or higher, and with a needle washing facility Column oven with temperature regulation from ambient plus 5 o C to 80 o C, and capable of holding 3 columns of 250 mm or more

10 COMPUTER SYSTEM AND SOFTWARE COMPUTER and PRINTER: Intel based, icore 5or above, At least 8 GB RAM, 1000 GB HDD, DVD/CD Writer, High Speed USB Ports, (at least 2 x USB 3.0) Network Card, (1Gbyte) Two at least 22 LCD Monitors, Keyboard, Mouse, with all the necessary cables, Color Printer Compatible with the above Specifications LC-MSMS SOFTWARE: Compatible with Windows 7, with upgrade to Windows 10 Easy to use single software platform for controlling all modules of LC and MSMS system Automated mass calibration and optimization of operating parameters Automated quantification and reporting of acquired samples LIMS compatible With pesticide and veterinary drug residues MS-MS-database System suitability, system security as well as system check functions must be provided which comply with Good Laboratory Practices (GLP) and Regulatory Conformity It should cover full digital instrument control, qualitative and quantitative processing, report creation, self-diagnosis and auto-tuning. The self-diagnosis feature of the software should enable diagnosis of the mass spectrometer and all connected LC units Auto Start-up and shutdown of the MS should be a single key operation Should have a contextual online help function Allow for the reprocessing of analytical results after an analysis is complete Allow the user to report results in a variety of concentration formats The reporting format should be flexible and easy to use in any desired format Ability to convert instrument data sets to standard formats like MS-EXCEL, pdf Should have its own log files for complete audit trails Should have quality control and diagnostic features Should have an audio-visual multi-media CD-ROM for maintenance and troubleshooting INSTALLATION, TRAINING AND TROUBLESHOOTING INSTALLATION: The system should be installed and commissioned by a qualified service engineer from the supplier Trial tests (PT, SRM or QC Samples from a recognized supplier) should be carried out after installation and results should be comparable with the literature/accepted values For a good and timely technical support, the supplier must have a technical subsidiary

11 of the supplier/manufacturer in Africa, with easy access to fast technical support. TRAINING: The supplier should provide on-site system overview and training on the operation and maintenance of the complete system provided by the supplier s application specialist following a successful system installation. The training must be sufficient enough to enable the operators with the knowledge to carry out the general operation and maintenance of the complete system Package should also include further training on the system and application3 to 6 months after a period of exposure time on the instrument (exact time to be scheduled by the laboratory) WARRANTY: At least 2 years warranty after the installation should be provided. The complete system should be accompanied with a Declaration of Conformity Certificate System must be supplied with complete user manuals, service manuals, circuit diagrams, and circuit description, all in English language. ADDITIONAL ACCESSORIES SPARES and CONSUMABLES Full sets of spares and consumables(such as ferrules, tubing, fittings, adaptors, flow cell, guard columns, syringes, needles if any for sample injection, vials, caps, and septa) for 2 years of trouble free operation for the instrument and associated accessories UPS A 10KVA Uninterrupted Power Supply (UPS) system with 1 hour backup from a standard manufacturer. The UPS specification can be changed accordingly with the requirements of the selected LC-MSMS System and accessories GASES Gas Generators capable of supplying all necessary gases with the required purity, pressure and flow rate, as required by the LC-MSMS instrument should be provided. It should be complete with all necessary accessories. If Gas Generators for a required gas is not available, two sets of the additional gases with the specific purity and pressure necessary for installation and operation of the LC- MSMS should be provided with the instrument Gas supply system should also include a dual stage gas pressure regulators for each cylinder, gas purification panels, gas supply manifold for switching gas cylinder, valves, connectors, and tubing MAINTENANCE KIT Complete for normal servicing and repairing of the LC-MSMS system COLUMNS 10 pieces of 50mm x 2.1 mm x 2.6 µm C-8 10 pieces of 100mm x 2.1 mm x 3 µm C-18

12 GENERAL ICP-MS SPECIFICATION A bench-top ICP-MS system with high sensitivity, mass resolution, excellent mass bias stability, analysis of elements and isotopes in variety of samples The system should be integrated with collision reaction interface for interference-free analysis using simple collision and reaction gases TECHNICAL SPECIFICATIONS Multichannel peristaltic pump which can support variable flow rates with a minimum of 4 channels The sample introduction system, torch and cones should be easily accessible for routine cleanup and maintenance practices Complete computer controlled adjustment of the torch position in X, Y and Z directions with independent movement in each direction Computer controlled 27/40 MHz RF generator with variable power output with a minimum range of 600W to 1600W or better Plasma should be able to operate on both hot and cold plasma conditions and fully controlled via the software Cell technology should be capable of removing polyatomic and isobaric interferences Capable of analyzing multiple isotopes during a single analysis Ion optics should have excellent focusing Fully interlocked for operational simplicity, complete operator safety and full protection of the instrument against damage Capable of measuring a single monoisotopic element over a concentration range of 0.5 ppt to 500 ppm under the same operating conditions System should have an over range protection and fully automated detector cross calibration with good linearity The detector should be easily replaceable by the operator and should have a minimum of 9 orders of linear dynamic range, with background noise of <0.5 cps Mass Quadruples with rods made of stainless steel with pre-filters operated at 3 MHz or better with mass range of 3 to 256 amu or better, a resolution of 0.3 amu or better, a scan speed of 5000 amu per second or better, and minimum dwell time of 100 µs or better System must be supplied with complete user manuals, service manuals, circuit diagrams, and circuit description

13 COMPUTER SYSTEM AND SOFTWARE COMPUTER and PRINTER: Intel based, icore 5 or above, At least 8 GB RAM, 500 GB HDD or above, DVD/CD Writer, High Speed USB Ports, Network Card, 1 Gbyte At least 22 LCD Monitor, Keyboard, Mouse, with all the necessary cables, Color Printer Compatible with the above Specifications ICP-MS SOFTWARE: Compatible with Windows 7 Operator friendly with the ability to guide users through method and sequence development Able to control RF generator power and all gas flows (nebulizer, plasma and auxiliary) Able to display and flags analytical results out of specification and QC failures Allow the user to report results in a variety of concentration formats such as ppb, ppm, µg/l, µg/g, mg/l Preferably have the capability for optimization of the instrument including plasma position, ion lenses, mass calibration and detector calibration Quality Control and Diagnostic features so that instrument can detect slope and intercept drifts, malfunctions, and any other errors for fast resolution Allow calculation of duplicates, spikes, and dilution/weight factors Ability to convert instrument data sets to standard formats like MS-EXCEL, Ability to add additional samples to the end of an analytical run that is already in progress Allow all operating parameters like detector voltages and plasma settings to be stored or printed out Built in interference corrections for all measurement modes to correct for isobaric and polyatomic interferences Capable of operating in qualitative, quantitative, semi-quantitative, isotope ratio and isotope dilution analysis modes Capable of multi-element external calibration, method of standard additions, and isotope ratios Allow for the reprocessing of analytical results after an analysis is complete

14 INSTALLATION, TRAINING AND TROUBLESHOOTING INSTALLATION: The system should be installed and commissioned by a qualified service engineer from the supplier Trial tests (PT, SRM or QC Samples from a recognized supplier) should be carried out after installation and results should be comparable with the literature/accepted values For a good and timely technical support, the supplier must have a technical subsidiary of the supplier/manufacturer in Africa, with easy access to fast technical support. TRAINING: The supplier should provide on-site system overview and training on the operation and maintenance of the complete system provided by the supplier s application specialist following a successful system installation. The training must be sufficient enough to enable the operators with the knowledge to carry out the general operation and maintenance of the complete system Package should also include further training on the system and application 3 to 6 months after a period of exposure time on the instrument (exact time to be scheduled by the laboratory) WARRANTY: At least 2 years warranty after the installation should be provided ADDITIONAL ACCESSORIES AUTO SAMPLER Compatible with the ICP-MS and capable of holding 150 test tubes and above Equipped with compatible racks capable of holding 40 test tubes and above Fully controlled by the ICP-MS Software Includes a rinse station Comes with an auto diluter WATER CHILLER/RECIRCULATOR Compact and low noise water chiller or recirculation with a capacity to cool all the necessary components of the ICP-MS EXHAUST SYSTEM Fume exhausts system sufficient enough for the ICP-MS including the exhaust fan and other necessary accessories. Installation of the exhaust system will be done by the laboratory. SPARES and CONSUMABLES Full sets of spares and consumables for 2 years of trouble free operation for the instrument and associated accessories

15 UPS A 40KVA Uninterrupted Power Supply (UPS) system with 1 hour backup from a standard manufacturer. The UPS specification can be changed accordingly with the requirements of the selected ICP-MS System and accessories STANDARDS Traceable multi-element standard solutions for the ICP-MS to be presented with a certificate of analysis MAINTENANCE KIT Complete for servicing and repairing of the ICP-MS system GASES One set of all gases (Ar, He, ) with the specific purity and pressure necessary for installation and operation of the ICP-MS should be provided with the instrument Gas supply system should also include a dual stage gas pressure regulators for each cylinder, gas purification panels, gas supply manifold for switching gas cylinder, valves, connectors, and tubing

16 CERTIFIED REFERENCE MATERIALS SPECIFICATION Note: All Reference Materials should be traceable to the international level MATRIX ANALYTES REMARK Peanut Aflatoxin G 2, G 1, B 2, B 1 Cereal/Maize Aflatoxins G2, G1, B2, B1 Green Coffee Ochratoxin A Cereal Matrix Containing at least 20 minerals and heavy Minerals and Heavy Metals metals including certified values for Pb, Cd, Hg, Se, As, Fe, Cu, Zn, Mn, Ca, Mg, Na,and K Vegetables Containing at least 20 minerals and heavy Minerals and Heavy Metals metals including certified values for Pb, Cd, Hg, Se, As, Fe, Cu, Zn, Mn, Ca, Mg, Na, and K Water Containing at least 20 minerals and heavy Minerals and Heavy Metals metals including certified values for Pb, Cd, Hg, Se, As, Fe, Cu, Zn, Mn, Ca, Mg, Na, and K Food Amino Acids Containing at least 15 Amino Acids Solid Food Organochlorine Pesticides Containing at least 15 Organochlorine Pesticides including Aldrin, BHC, Lindane, Chlordane, Endrin, DDT Containing at least 15 Organophosphorus Solid Food Organophosphorus Pesticides including Dimethoate, Pesticides Thionazin, Phorate, Parathion, Famphur, Disulfoton, Malathion Vegetable Vitamins Containing water soluble vitamins including B, C Solid Food Vitamins Containing fat soluble vitamins including A, E, K1, D2, D3, β-carotene ANALYTICAL REFERENCE STANDARDS Pure Solid A, B1, B2, B3, B5, B6, B9, B12, C, D1, Vitamins Standards D2, D3, E, K1, β-carotene Pure Standards Sugar Profile Glucose, Fructose, Sucrose, Maltose BHC, Aldrin, Lindane, Oxychlordane, trans-chlordane,endosulfan, DDT, DDE, DDD, Endrin,Dieldrin, Pure Solid Malathion, Pesticides Standards Pentachlorobenzene,Hexachlorobenzene, Heptachlor, Methoxyclor, Mirex, Pirimophos, Parathion, Methidathion, Ethion, Diazinon, Bromophos

The instrument should have a mass range from 2 to 2000 m/z or better Interface

The instrument should have a mass range from 2 to 2000 m/z or better Interface Revised Specifications for Liquid Chromatography Mass Spectrometry (LC-MS/MS ) Triple Quadrupole Specification for Ultra-Fast Liquid Chromatography system Solvent Delivery 1) A quaternary Pump system for

More information

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310 www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Varian 310 310 LC/MS Manual System INCLUDES: 310-MS LC/MS triple quadrople

More information

Indian Institute of Technology Kanpur Environmental Engineering and Management Department of Civil Engineering

Indian Institute of Technology Kanpur Environmental Engineering and Management Department of Civil Engineering Indian Institute of Technology Kanpur Environmental Engineering and Management Department of Civil Engineering Professor Vinod Tare Phones:+91-0512-2597791,7792 Email: vinod@iitk.ac.in Post Office: IIT

More information

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS Agilent 7800 ICP-MS Specifications and Typical Performance Fast track metals analysis with Solution-Ready ICP-MS The Solution-Ready Agilent 7800 Quadrupole ICP-MS combines proven, robust hardware, auto-optimization

More information

Setting a New Standard in Flash Chromatography Performance

Setting a New Standard in Flash Chromatography Performance Setting a New Standard in Flash Chromatography Performance What s New Faster Flow rates, up to 300 ml/min Higher pressures, up to 300 psi (20 bar) Bigger touchscreen, 12 or 15 inches Wider Dynamic Range

More information

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection This user guide does not have the intention to introduce you to any of the theory and/or principles behind

More information

DOS in Food Science & Nutrition, Manasagangotri, Mysore

DOS in Food Science & Nutrition, Manasagangotri, Mysore Sl No UNIVERSITY OF MYSORE DOS in Food Manasagangotri, Mysore 570 006. TENDERS FOR THE SUPPLY OF EQUIPMENTS, NETWORKING & COMPUTATIONAL FACILITIES FOR UNIVERSITY OF MYSORE (UNDER UGC XI SCHEME) INVITATION

More information

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION Standard OQ Test Suite This document describes the test program for qualifying LC analytical-scale Agilent systems; the following table lists

More information

M/s. Thermo fisher Scientific

M/s. Thermo fisher Scientific CLARIFICATIONS AND RESPONSES IN THE PRE BID MEETING HELD ON 19 TH AUGUST 2013 IN OUR COMMITTEE ROOM FOR THE PROCUREMENT OF DIOXIN ANALYSER (GC-MS/MS) File No : PUR/IMP/178/14 Description of Item : DIOXIN

More information

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD) Procedure No: SOP-026 Revision No: 1.0 January 24, 2011 Page No.: 1 of 10 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to meet

More information

GCMSD-Headspace Analysis SOP

GCMSD-Headspace Analysis SOP Before you start GCMSD-Headspace Analysis SOP Method and Sequences names are restricted to 50 characters (MSD program will crash otherwise) The GC oven and Injection Ports need to be cooled to 50 oc to

More information

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist Thank you for purchasing an Agilent system. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is

More information

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction Application Note Rapid performance verification of AZURA systems with refractive index detector Method Keywords ID HPLC Quality control, system verification, refractive index, AZURA Analytical HPLC Plus

More information

LUMAZOTE T ECHNICAL BRO CHU RE

LUMAZOTE T ECHNICAL BRO CHU RE by Chemiluminescence Standards AST D4629 / ASTM D6069 / ASTM D 5176 / ASTM D 5762 / NF EN 12260 / NF M 07-058 Licence TOTAL LUMAZOTE T ECHNICAL BRO CHU RE ERALY & Associés Phone: +33 (0) 1 77 04 80 97

More information

FINAL REVISED TECHNICAL SPECIFICATION OF INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER (ICP-MS) WILL BE AS FOLLOWS:- GENERAL SPECIFICATIONS

FINAL REVISED TECHNICAL SPECIFICATION OF INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER (ICP-MS) WILL BE AS FOLLOWS:- GENERAL SPECIFICATIONS Ref No. INST/12(121)/2018-Pur Date: 31/12/2018 CORRIGENDUM Reference to NIT no. INST/12(121)/2018-Pur published in national newspapers on 07/09/2018 for purchase of equipment: ICP-MS WITH ACCESSORIES.

More information

Indian Institute of Technology Kanpur Samtel Centre for Display Technologies

Indian Institute of Technology Kanpur Samtel Centre for Display Technologies Fax: + 91-0512-2596620 Phones: + 91-0512-2596622,6088 Indian Institute of Technology Kanpur Samtel Centre for Display Technologies Enquiry number: SCDT/FlexE/2016-17/02 Date:05/05/2016 Sealed Quotations

More information

The instrument will process the samples one by one till all the samples have been cleaned up.

The instrument will process the samples one by one till all the samples have been cleaned up. Table of Contents SPE-01 Cleanup Station... 1 LC-04SP Valve System... 5 LC-04SP Standalone Valve... 10 LC-05 Auto Injector... 12 LC-06 Dosing Pump... 16 LC-08 Column Selector... 17 SPE-01 Cleanup Station

More information

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator Procedure No: SOP-029 Revision No: 1.1 (December 29, 2010) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality

More information

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Convergent Technologys product overview

Convergent Technologys product overview Convergent Technologys product overview Lab Diagnostics - Convergys 1100-1001 Convergys ISE Analyzer 1100-1003 Convergys ISE Analyzer 3 electrodes out of (K+, Na+, Li+, CL-, Ca++, ph)* 5 electrodes out

More information

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions Checklist NOTE: Do not unpack the shipping cartons. Check off each checklist box after satisfying each requirement as described

More information

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Technical Specifications of Hydrogen Isotope Handling and Recovery System SECTION - C TECHNICAL SPECIFICATIONS OF STORES AND DRAWINGS. Technical Specifications of Hydrogen Isotope Handling and Recovery System INSTITUTE FOR PLASMA RESEARCH GANDHINAGAR, GUJARAT 382428 ANNEXURE-I

More information

HPLC. Solvent Delivery Module Systems

HPLC. Solvent Delivery Module Systems HPLC Solvent Delivery Module Systems Who is GBC Scientific Equipment? GBC Scientific Equipment was founded in 1978 and is now the world's third largest and fastest growing manufacturer of atomic absorption

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions

More information

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS) Toxicology Gas Chromatography-Mass Spectrometry (GC-MS) 1.0 Purpose - This procedure specifies the required elements for the calibration and use of the Agilent Gas Chromatograph interfaced to the Agilent

More information

Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software

Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software TECHNICAL NOTE 43225 Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software Authors Dr. Elena Chernetsova, Application Specialist, Thermo Fisher Scientific, Bremen, Germany

More information

Application Note AN-107

Application Note AN-107 SPEC Sensor TM Characterization & Calibration Considerations Scope This document is provided to describe the considerations needed to characterize, calibrate, verify and validate the measurement performance

More information

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist Agilent Site Preparation Infinity II Checklist Preparative HPLC System Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion: Automated Determination of Dissolved Gases in Water Anne Jurek Abstract: The RSK-175 standard operating procedure was developed in order to determine the amount of dissolved gas in water. Due to the expansion

More information

Hiden QIC Series Gas Analysers Real-time gas analysis systems

Hiden QIC Series Gas Analysers Real-time gas analysis systems Hiden QIC Series Gas Analysers Real-time gas analysis systems vacuum analysis surface science plasma diagnostics gas analysis Application Focussed Options Multistream valves 20, 40 and 80 way versions

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs. Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography

More information

Quadruple mass spectrometers (transducer type)

Quadruple mass spectrometers (transducer type) Quadruple mass spectrometers that meet the need for sensitive analysis and low outgassing which were specifically designed to be controlled by PCs Quadruple mass spectrometers (transducer type) M-070QA-TDF,

More information

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric

More information

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications. OMNISTAR / THERMOSTAR The efficient solution for gas analysis. Intelligent software. Wide range of applications. OMNISTAR /THERMOSTAR The efficient solution for gas analysis. Intelligent software. Wide

More information

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator Procedure No: SOP-034 Revision No: 1.0 Revised Dec. 29, 2010 Page No.: 1 of 10 1. INTRODUCTION AND SCOPE This procedure is intended to describe the operations of the Dasibi model 5008 calibrator. The Dasibi

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2 GAS ANALYSER OXYBABY 6.0 for or Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and accurate

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

The Tekran Series 2600-IVS Difference!

The Tekran Series 2600-IVS Difference! Tel:+1-416-449-3084 Fax: +1-416-449-9298 The Tekran Series 2600-IVS Difference! Rev 021916 Method 1631 (Dual Gold Trap CVAFS) Method 245.7 (Direct CVAFS Analysis) US EPA IO-5 (Ambient Air) ASTM D-6350

More information

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no

More information

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT PA/PH/OMCL (16) 17 R QUALIFICATION OF EQUIPMENT ANNEX 2: QUALIFICATION OF GC EQUIPMENT Full document title and reference Document type Legislative

More information

Agilent Auxiliary Gas Module AGM 2. User s Guide

Agilent Auxiliary Gas Module AGM 2. User s Guide Agilent Auxiliary Gas Module AGM 2 User s Guide Notices Agilent Technologies, Inc. 1992, 1996, 1999, 2010 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Automatic Isokinetic Sampler. ST5 Evo

Automatic Isokinetic Sampler. ST5 Evo Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,

More information

Features of Jobin Yvon ICP Spectrometers

Features of Jobin Yvon ICP Spectrometers Features of Jobin Yvon ICP Spectrometers Jobin Yvon S.A.S., Emission Division, Application Laboratory, May 2003 1 Radio Frequency (RF) Generator 1.1 Solid-state generator The solid-state generator offers

More information

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION BEST KNOWN METHODS Transpector XPR3 Gas Analysis System DESCRIPTION The Transpector XPR3 is a third-generation, quadrupole-based residual gas analyzer that operates at PVD process pressures and is the

More information

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR) Procedure No: SOP-025 Revision No: 1.0 (January 21, 2011) Page No.: 1 of 8 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to

More information

Agilent 4100 MP-AES. Specifications. Runs on air

Agilent 4100 MP-AES. Specifications. Runs on air Agilent 4100 MP-AES Specifications Runs on air The Agilent 4100 MP-AES is a compact, bench-top microwave plasma-atomic emission spectrometer based on a robust, nitrogen plasma. It is suitable for elemental

More information

PRC CO ² -LASER PRESENTATION

PRC CO ² -LASER PRESENTATION Page 1 of 7 PRC CO ² -LASER PRESENTATION GENERAL CHARACTERISTICS - Embedded PC104 Electronics with exchangeable software allowing very easy integration of customer specified functions: such as eg. specific

More information

This test shall be carried out on all vehicles equipped with open type traction batteries.

This test shall be carried out on all vehicles equipped with open type traction batteries. 5.4. Determination of hydrogen emissions page 1 RESS-6-15 5.4.1. This test shall be carried out on all vehicles equipped with open type traction batteries. 5.4.2. The test shall be conducted following

More information

Tensiometer For the measurement of surface and interfacial tension

Tensiometer For the measurement of surface and interfacial tension Tensiometer For the measurement of surface and interfacial tension Precise measuring instruments for research and industry Precision, flexibility, and reliability LAUDA Scientific offers proven solutions

More information

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Agilent 1220 Infinity II LC Mobile Upgrade Kit Agilent 1220 Infinity II LC Mobile Upgrade Kit Note 1220 Infinity II LC Mobile Upgrade Kit This note describes the procedures to install an Mobile Upgrade kit to an existing Agilent 1220 Infinity II LC.

More information

Improve Process Reliability

Improve Process Reliability Convenient Conductivity Calibration to Meet Pharmacopeia Regulations Pharmacopeias require that conductivity measurement systems be periodically calibrated to ensure their precision. The range of accessories

More information

Valve test benches. Systems overview

Valve test benches. Systems overview Valve test benches Systems overview About us In the past few years WIKA has successfully integrated renowned manufacturers of calibration equipment into the group. With these established brands within

More information

no peaks missing peaks too small peaks increasing retention decreasing retention

no peaks missing peaks too small peaks increasing retention decreasing retention GC Troubleshooting We can help you. 1. Observation: no peaks no peaks missing peaks too small peaks increasing retention decreasing retention declining baseline rising baseline bleeding plateaus interfering

More information

Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS

Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS UCT Part Numbers: CUQAX22Z Clean-Up C8+QAX, 2mg/1mL BETA-GLUC- ml Beta-Glucuronidase Enzyme, liquid form SLAQID21-3UM

More information

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations OXYBABY 6.0 for O 2 or O 2 /CO 2 Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and

More information

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1250 METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1.0 Scope and Application. 1.1 Analytes. Analyte CAS No. Sensitivity Total Organic Compounds N/A

More information

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300 Technical Note GA-300 Overview The GA-300 CO2 and O2 Gas Analyzer is easy to use, robust, and adaptable to human, animal, and plant applications. The GA-300 has two analog outputs to allow recording and

More information

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300 Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300 The Thermo Scientific icap 6300 Inductively Coupled Plasma Optical Emission

More information

Pool and Spa. Water Testing

Pool and Spa. Water Testing Pool and Spa Water Testing Pocket Digital Testers for Pools HI-701 Checker: Free Chlorine Hand-held Colorimeter The HI-701 is a simple, accurate and cost effective way to measure free chlorine. Free Chlorine:

More information

Agilent 4200 MP-AES. Specifications. Runs on air

Agilent 4200 MP-AES. Specifications. Runs on air Agilent 4200 MP-AES Specifications Runs on air The Agilent MP-AES is a compact, bench-top microwave plasma-atomic emission spectrometer based on a robust, nitrogen plasma. It is suitable for elemental

More information

Series Environmental Chambers

Series Environmental Chambers 3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable

More information

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE. Gases&Technology FEATURE Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. B Y M A T T H E W M O N A G L E Abstract Bulk gases are often delivered to

More information

AUTOMATIC HOSE TEST UNIT, TYPE SPU

AUTOMATIC HOSE TEST UNIT, TYPE SPU VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE

More information

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.

More information

1)! DO NOT PROCEED BEYOND THIS MARK

1)! DO NOT PROCEED BEYOND THIS MARK Operating Instructions for X-ray Photoelectron Spectrometer: Physical Electronics Model 555 XPS/AES (John H. Thomas, III, Ph.D., Electron Spectroscopy) Sample Insertion: figure 1. Sample insertion rod

More information

Thermo Scientific Model 146i Principle of Operation

Thermo Scientific Model 146i Principle of Operation Thermo Scientific Model 146i Principle of Operation The Model 146i Multi-gas Calibrator dilutes calibration gases to precise concentrations. The diluted gases are used to perform zero, precision and Level

More information

High Performance Mass Spectrometers

High Performance Mass Spectrometers High Performance Mass Spectrometers For Vacuum and Semiconductor Process Monitoring Detailed product information / introduction MOCVD semiconductor processing Applications: XXCVD/MOCVD XXPECVD XXALD XXSputtering

More information

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015 page 1 of 6 TNI Standard EL-V1M4 Sections 1.7.1 and 1.7.2 September 2015 Description This TNI Standard has been taken through all of the voting stages and has received consensus approval by the TNI membership.

More information

Rapid and Reliable Detection of Dissolved Gases in Water

Rapid and Reliable Detection of Dissolved Gases in Water Rapid and Reliable Detection of Dissolved Gases in Water Andrea Caruso and Massimo Santoro Thermo Fisher Scientific, Milan, Italy Application Note 005 Key Words Chromeleon CDS, Environmental, Fracking,

More information

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC Evaluation of linear and step gradient performance and retention time precision of the Agilent 12 Series Rapid Resolution LC This document is believed to be accurate and up-to-date. However, Agilent Technologies,

More information

Residual Gas Analysis Systems for Industry

Residual Gas Analysis Systems for Industry HIDEN RC SYSTEMS QUADRUPOLE MASS SPECTROMETERS FOR RGA, GAS ANALYSIS AND PROCESS MONITORING The HAL RC systems are designed for RGA, gas analysis and process monitoring applications including leak detection,

More information

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008 UNITY 2 TM Air Server Series 2 Operators Manual Version 1.0 February 2008 1. Introduction to the Air Server Accessory for UNITY 2...2 1.1. Summary of Operation...2 2. Developing a UNITY 2-Air Server method

More information

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere! The portable Gas Chromatograph is now more versatile than ever. DPS Instruments is pleased to present the newest Portable Companion 2 Gas Chromatograph with room for 2 Detectors. The Companion 2 GC was

More information

FLUORESCENCE DETERMINATION OF OXYGEN

FLUORESCENCE DETERMINATION OF OXYGEN FLUORESCENCE DETERMINATION OF OXYGEN Objectives This experiment will familiarize the students with the principles of fluorescence quenching as well as the Ocean Optics FOXY Fiber Optic Sensor System. Spectra

More information

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion Delivering the Right Results 736 Series: Oxygen/Nitrogen by Inert Gas Fusion The 736 family of Elemental Analyzers is designed for routine measurement

More information

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator Procedure No: SOP-012 Revision No: 1.2, January 27, 2011 Page No.: 1 of 7 1. INTRODUCTION AND SCOPE This procedure is intended to describe the operations of the Sabio model 2010 and 4010 dilution calibrators.

More information

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices Oneida Research Services, Inc. 8282 Halsey Road Whitesboro, NY 13492 Phone: (315) 736-5480 FAX: (315) 736-9321 1.0 Purpose The

More information

Precisely HPLC. Hints, Tips, Guidelines and Important Considerations. Presenters: Wilhad Reuter / Tom Breslin

Precisely HPLC. Hints, Tips, Guidelines and Important Considerations. Presenters: Wilhad Reuter / Tom Breslin HPLC Hints, Tips, Guidelines and Important Considerations Presenters: Wilhad Reuter / Tom Breslin Important HPLC Solvent Characteristics: ALL injected compounds/diluents must be soluble High purity and

More information

FROG-4000 TM Chemical Analysis System

FROG-4000 TM Chemical Analysis System FROG-4000 TM Chemical Analysis System User s Manual Defiant Technologies, Inc. 2015 Vol.5 This page is intentionally left blank. FROG-4000 TM Chemical Analysis System User s Manual Defiant Technologies,

More information

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more! After years of development and testing, DPS Instruments is pleased to present the newest, most expandable and versatile Gas Chromatography Systems in history. The DPS 600 Series GC systems are the world

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide / Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 8655-4 First edition 2002-09-15 Piston-operated volumetric apparatus Part 4: Dilutors Appareils volumétriques à piston Partie 4: Diluteurs Reference number ISO 8655-4:2002(E)

More information

AKTA pure 25 New Owner s Intro

AKTA pure 25 New Owner s Intro AKTA pure 25 New Owner s Intro The exercise below will give a quick demonstration of how easy and intuitive the AKTA pure 25 will be for you in demonstrating downstream processing to your students. Steps

More information

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation Ruskinn Hypoxia and Anoxia Workstations The Ruskinn range of hypoxia workstations has been designed to replicate low oxygen in vivo physiology providing the ideal research platform for cell biologists

More information

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany Manual Degasser DDG-75 April 2007 1 Manual Online Degasser DDG-75 DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE-68766 Hockenheim Germany Tel. +49-6205-9450-0 Fax. +49-6205-9450-33 email info@duratec.com

More information

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay Summary This assay measures Human Granulocyte Colony Stimulating Factor (G-CSF) in a 96-well

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

628 Differential Pressure Decay Leak Tester

628 Differential Pressure Decay Leak Tester 628 Differential Pressure Decay Leak Tester The 628 puts Uson s industry leading differential pressure decay sensitivity in your hands and in your budget with no compromise in quality, reliability, and

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a

More information

Rimage Everest 600 Thermal Retransfer Printer

Rimage Everest 600 Thermal Retransfer Printer Rimage Everest 600 Thermal Retransfer Printer Superior Print Technology: Superior Results CONTENTS I. Overview II. Printer Comparison III. Print Modes IV. Advantages of Thermal Retransfer Printing V. Printer

More information

Tensiometer For the measurement of surface and interfacial tension

Tensiometer For the measurement of surface and interfacial tension Tensiometer For the measurement of surface and interfacial tension Precise measuring instruments for research and industry Precision, flexibility, and reliability LAUDA Scientific offers proven solutions

More information

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion Delivering the Right Results ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion The ONH836 Oxygen/Nitrogen/Hydrogen family of Elemental

More information