GAS ANALYSER OXYBABY M+ for O 2. or O 2 /CO 2. standard version
|
|
- Kelley Fowler
- 1 years ago
- Views:
Transcription
1 GAS ANALYSER OXYBABY M+ for O 2 or O 2 standard version Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and accurate sample tests at the packaging machine, in stores or in laboratories. M+ a cost effective mobile alternative to tabletop / fixed analysers. Ensure that the quality of packaged product is maintained (HACCP), guaranteeing continued customer satisfaction. The ideal instrument for sample tests with a minimum sample gas requirement, allowing the smallest of modifi ed atmosphere packages (MAP) to be tested. Integrated data log of the last 100 measurements assigned to specifi c product names or line numbers. Benefits minimum sample gas requirement for smallest packs cordless operation using rechargeable batteries simple one hand operation easy to clean large illuminated graphic display measurement alternatively also by hose multilingual menu guide: German, English, French, Italian, Dutch, Swedish, Finnish, Spanish, Polish, Japanese and Russian integrated needle cover to protect the user long lifetime of O 2 sensor (approx. 2 years) low maintenance costs Complete in carrying case charging device and mains adaptor further information on Video OXY1 - F01/J5 subject to change CD-ROM with: - operating instructions 2 spare needles 2 spare fi lters set of 100 rubber seals case dimensions (HxWxD): approx. 325x385x115 mm (12.79x15.16x4.53 inch), case weight: approx. 1.7 kg Options hose with Luer-Lok connection for stationary measurement! Please note our variety of accessories on the following pages
2 GAS ANALYSER OXYBABY M+ for O 2 or O 2 standard version M+ O 2 M+ O 2 Gases O 2 balance gas: N 2, (Ar or others on request) O 2 and/or CO 2 balance gas: N 2, (Ar or others on request) Measuring principle O 2 electrochemical cell Measuring principle CO 2 IR-absorption Sensor lifetime O 2 approx. 2 years (in air at 20 C / 68 F) Sensor lifetime CO 2 long lifetime Measuring range 0 100%; in 0.1%-steps Sample gas requirement < 10 ml Sample time max. 10 sec. Calibration simple two point calibration Sampling automatic via needle using integrated pump Data log last 100 measurements assignment of measurements to different product names or line numbers Multilingual German, English, French, Italian, Dutch, Swedish, Finnish, Spanish, Polish, Japanese and Russian Temperature (gas/environment) 5 40 C ( F) Display backlit Shut down automatic after 2 minutes of non-use Housing shock resistant plastic Weight approx. 600 g (without accessories) Dimensions (HxWxD) 187 x 106 x 91 mm (7.4 x 4.2 x 3.6 inch) (without needle) Power supply 3 integrated rechargeable batteries (mains adaptor + charging device included) Charging device V AC OXY1 - F01/J5 subject to change Approvals Company certifi ed according to ISO 9001 and ISO CE-marked according to: - EMC 2004/108/EC - Low Voltage Directive 2006/95/EC for food-grade gases according to: - Regulation (EC) No 1935/2004
3 GAS ANALYSER OXYBABY Accessories Table-rack This stabile and stable table-rack from stainless steel is ideal for use as table top version. Connector tube with Luer-Lok-connection is available for connection with. The table-rack is suitable for all models and has two deposits for needles. It is also usable as support. Integrated barcode-reader If you mark the data by barcode it s possible to receive an integrated barcode-reader for easily and quick data logging of inspector, product and packaging line for your 6.0. Only available for 6.0. Bluetooth table printer OXY5 - B01/J4 subject to change Select Bluetooth equipment for your 6.0 and print wireless directly on-site your results of measurement via small and handy table printer. Practical, quick and easily. Other models, options and accessories available upon request.
4 ACCESSORIES OXYBABY for bo les, cans and mini packages Can-Piercer The Can-Piercer is essential for head space analysis of bottles and cans. Safe interlocking and easy handling guarantees optimal quality controls also for bottles and cans with metal or plastic caps. The Can-Piercer can be adjusted up to 390 mm maximum bottles - or cans height. The integrated needle protection and robust needles prevents needle breakage. Material: steel Weight: 7,5 kg (without ) Dimensions (HxWxD): 585 x 155 x 235 mm (packed, without ) Suitable for M+ and 6.0. Aquacheck Aquacheck is ideal for mini packages lower 2 ml sample gas volume. The gas volume from two or more packages is collected in the water and analysable by the. Material: stainless steel CP1 - C01/A5 subject to change Other models, options and accessories available upon request. The Aquacheck is available with and without water container. Suitable for M+ and 6.0.
5 ACCESSORIES OXYBABY for bo les, cans and mini packages Can-Piercer: Application in practice CP1 - C01/A5 subject to change Order-No. Needle length in mm Hight of bottles, cans Bottle holder Overpressure Pressure regulator w. ball valve and gauge bar Calibration module + fl ow regulator * mm 270 cm x <1 bar(g) x mm 270 cm x x >1 bar(g) x mm 390 cm x x >1 bar(g) x mm 390 cm x x >1 bar(g) x mm 270 cm x >1 bar(g) x x x Gauge 0-6 bar Conversion possible Application beverage cans (without gas / without overpressure), eg. juice bottles, bevarage cans (with gas / with very high overpressure, sparkling) Device without pump mm 390 cm x 0-4 bar x x bottles, beverage cans no connection, only pressure measurement *to prevent the from damage by too high overpressure, too high fl ow rate, the calibration module has to be connected between calibration gas / zero gas and. To obtain clear results we adjust a pressure of 0.5 bar and a fl ow rate of approx. 100 ml/min. Attention: The correct model of the required Can-Piercer type is dependent on - the kind of liquid to be analysed, - the available overpressure in the bottles / cans, - the volume of the available headspace of the bottles / cans, - the thickness of the caps / can walls Our recommendations: Case Application Example Recommendation , for beverages containing gas cola, mineral water, lemonades, beer, etc. or for beverages, free of gas juices, wine, water mixtures, etc EXTREME CASE: for beverages containing gas with very high overpressure, small volume in the head space of the cans / bottles and / or very strongly sparkling for sole pressure measurement from a can or bottle Retrofit components and spare parts: Bottle holder Tubular extension for CAN-Piercer Can-Piercer holder (needle 18.5 mm) Can-Piercer holder (needle 8.5 mm) Can-Piercer holder (needle 5.5 mm) Can-Piercer holder (pressure measurement) Needle connection with fi lter and RV Hose Luer-Lock connection female
GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2. premium version
GAS ANALYSER OXYBABY 6.0 for O 2 or O 2 premium version Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for
GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2
GAS ANALYSER OXYBABY 6.0 for or Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and accurate
WITT-Gasetechnik GmbH & Co KG
Gas analysers Portable multi-functional Analyser MAPY 4.0 for, C, He or /C vertical display inclined display Product Information / Analysing System for the monitoring of protective atmospheres in food
Dräger X-act 5000 Automatic Dräger Tube Pump
Dräger X-act 5000 Automatic Dräger Tube Pump The automatic tube pump Dräger X-act 5000 is the first all-in-one solution designed for measurements with Dräger short-term tubes and for sampling tubes and
Digital pressure gauge Model CPG500
Calibration technology Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 Applications Calibration service companies and service industry Measurement and control laboratories Quality assurance
This multi-functional device allows the determination of up to six quality parameters with only one measurement:
Devices for determination of the gas quality For verification of several parameters in one operation 3-038-R... Multi-Analyser without return system 3-038R-R... Multi-Analyser with return system This multi-functional
Additel 761 Automated Pressure Calibrators Selection Guide
/ Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95
Additel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
Pneumatic service kit Model CPG-KITP
Calibration technology Pneumatic service kit Model CPG-KITP WIKA data sheet CT 93.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service industry
Mass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
STA. Double regulating valves DN 15-50
STA Double regulating valves DN 15-50 IMI TA / Balancing valves / STA STA The STA double regulating valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for
Instruments for Measurement of Dissolved Carbon Dioxide and Oxygen in Beverages
Instruments for Measurement of Dissolved Carbon Dioxide and Oxygen in Beverages Lab and At-line ::: Unique Density & Concentration Meters Wherever You Are: Measurement of Dissolved C in Beverages In the
How much do customer returns cost you?
TECHNOLOGY FOR GASES How much do customer returns cost you? Benefit from WITT s certified quality systems for leak detection of all types of packaging Keyword: HACCP ISO 000 approval for food safety LEAK-MASTER
Additel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure / Process Calibration Equipment Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005%
STAD. Balancing valves DN (MD60, MD61, MD62)
STAD Balancing valves DN 15-50 (MD60, MD61, MD62) IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited
DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
WHEATON. Peristaltic Pumps. Advancing the Science of Liquid Handling
WHEATON Peristaltic Pumps Advancing the Science of Liquid Handling WHEATON Peristaltic Pumps Advancing the Science of Liquid Handling Highly intuitive Icon Driven User Interface enables fast, easy setup
Hydraulic pressure balance Model CPB5800
Calibration technology Hydraulic pressure balance Model CPB5800 WIKA data sheet CT 31.11 for further approvals see page 8 Applications Primary standard for calibrating the pressure scale in a hydraulic
AIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES
Series AIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES Standard Air Chucks 374 Flow-Thru Air Chucks 375 Standard Pencil Tire Gauges 376 Dual Foot Tire Gauges 377 Dial Tire Gauges 378 Digital Tire Gauges 379
EasyLine Continuous Gas Analyzers. So smart, they re simple
EasyLine Continuous Gas Analyzers So smart, they re simple Reliable Economic Powerful EasyLine is both a powerful and affordable line of instruments for the monitoring of gas concentrations in numerous
Industrial pressure controller Model CPC4000
Calibration technology Industrial pressure controller Model CPC4000 WIKA data sheet CT 27.40 Applications Oil and gas industry Industry (laboratory, workshop and production) Transmitter and pressure gauge
THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED
THE COMPACT LINE Mobile power packs in convincing BAUER quality 100 140 l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED COMPACT LINE mobile breathing air compressors for high demands Due to its legendary
We measure it. For gas and water installers. testo hpa. bar
Pressure measuring instruments For gas and water installers testo 312-2 hpa testo 312-3 testo 312-4 bar C testo 312-2 / testo 312-3 Pressure meters for gas and water fitters testo 312-2 testo 312-2, fine
Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist
Thank you for purchasing an Agilent system. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is
6200 Isoperibol Calorimeter Model Number: 6200
Parr Instrument Company 6200 Isoperibol Calorimeter Model Number: 6200 Tests Per Hour: 4 8 Operator Time Per Test: 6 Minutes Precision Classifcation: 0.05 0.1% Class Jacket Type: Isoperibol, Water Jacket
Expert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
Valve Proving System VDK 200 A S02
Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
OPCom With laser diode Measurement range 4, 6,14 and 21 µm(c) Operating pressure up to 500 bar
Pa r t i c l e M o n i t o r OPCom With laser diode Measurement range 4, 6,14 and 21 µm(c) Operating pressure up to 500 bar 100.10-1e D e s c r i p t i o n Application As stationary particle monitor in
HI 2314 HI 2315 HI 23151
Instruction Manual HI 2314 HI 2315 HI 23151 Multi-Range Conductivity Meters for Laboratories www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
Rope measurement devices program PFEIFER SEIL- UND HEBETECHNIK GMBH
02/2015 SEIL- UND HEBETECHNIK GMBH Rope measurement devices program DR.-KARL-LENZ-STRASSE 66 D-87700 MEMMINGEN TELEPHONE +49 (0) 83 31-937-267 TELEFAX +49 (0) 83 31-937-341 E-MAIL wireropes@pfeifer.de
300 Held Drive Northampton Pa
300 Held Drive Northampton Pa 18067 610.262.6090 June 10, 2015 Recommended testing for verifying device performance. Intervals of testing are to be set by the Healthcare Provider / Dealer. Table of Contents
STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves
STAD-D Balancing valves Balancing valve for domestic water systems, DN 15-50 Balancing valves IMI TA / Balancing valves / STAD-D STAD-D The STAD-D balancing valve delivers accurate hydronic performance
Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter
Technical Data Sheet KROHNE 12/2004 7.02516.21.00 CH/GR OPTIMASS 7000 Custody Transfer Mass Flowmeter with single straight measuring tube OIML R117 Pattern Approval Accuracy classes 0.3 / 0.5 / 1.0 / 1.5
User Manual. Quantos Automated Dosing Liquid Module
User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if
SF 6. Gas Handling. DILO. Sustainably tight. Made in Germany
Gas Handling DILO. Sustainably tight. Made in Germany 1 Table of contents information / General 04 08 gas refilling and evacuating devices 09 26 gas service carts 27 84 Micro Series 31 34 Mini Series
AES-28/50/75/110/150 RFG Sterilization Autoclaves with counter pressure and fast cooling
AES-75 RFG Advantages: Reduces the total cycle time until 50%. At the end of the process you can manipulate the sterilized materials thanks to output temperature set point. This equipment is design to
SF 6 Product Guide. Gas Analysis Instruments and Accessories
SF 6 Product Guide Gas Analysis Instruments and Accessories Cambridge Sensotec Ltd specialises in the design and manufacture of gas analysis equipment under the Rapidox brand name. Based in the UK, the
KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media
FEATURES 50 mbar to 400 bar, 5 to 6000 psi gage or absolute pressure For many industrial gases and liquids 00, 0545, 05, 6 or 40 ma output Field interchangeable EMC according to EN 66-8 MEDIA COMPATIBILITY
DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators
Features Ranges -14.7 to 10,000 psi Accuracy from 0.025% full scale (FS) Integral combined pressure/vacuum pump Dual readout: input and output 4 to 20 ma loop test: auto step and ramp Intrinsically safe
BY GREGGERSEN CATA LOG
MEDICAL DEVICES BY GREGGERSEN CATA LOG COMBINATION UNITS t h e r e i s n o s u b s t i t u t e CATALOG COMBINATION UNITS Hawk variants AND THEIR AREAS OF APPLICATION The HAWK PORTABLE EMERGENCY TREATMENT
HIGH FLOW HIGH PRESSURE PUMP type BMS
When you have to test objects on different locations within your workshop, the mobile pump system BMS gives you the possibility to test adequately on different sites. Through its wheels (or forklift pockets)
Valve INV-907. Instructions. 1 Introduction. 2 Installation. Safety. Unpacking. Installing the valve
Instructions 1 Introduction is a motorised rotary 7 port valve. The valve is used in ÄKTA design chromatography systems. It is powered from the ÄKTAdesign P-900 series system pump, and is controlled from
Pressure/Vacuum Diaphragm Valve PROTEGO UB/SF. deflagration- and endurance burning-proof
deflagration- and endurance burning-proof PROTEGO UB/SF 7 Ø b 4 The set pressure is adjusted with a freeze resistant water-glycol mixture, which assures safe operation under extreme cold weather conditions.
SIHI LPH-X - Liquid Ring Compressors
- Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a
Met One E-BAM Particulate Monitor
STANDARD OPERATING PROCEDURES Met One E-BAM Particulate Monitor AMBIENT AIR MONITORING PROGRAM for the 130 LIBERTY STREET DECONSTRUCTION PROJECT LOWER MANHATTAN DEVELOPMENT CORPORATION 1 Liberty Plaza
Elcometer 2300 Rotational Viscometers. elcometer.com
elcometer.com 1 Available in four versions with a choice of low to medium or medium to high viscosity ranges, either manually or PC controlled, the range of rotational viscometers can be used to measure
water purification cylinders & accessories
water purification cylinders & accessories The exchange cylinder concept If you require purified water with low expenditure, then the SUEZ Cylinder Exchange Service is for you. Simply purchase the required
UNITS /2017-E ENDOFLATOR 50. The New High-Performance Insufflator with Integrated Heating Element from KARL STORZ
UNITS 11 3.3 10/2017-E ENDOFLATOR 50 The New High-Performance Insufflator with Integrated Heating Element from KARL STORZ ENDOFLATOR 50 The new high-performance insufflator with integrated heating element
TBV-CM. Combined control & balancing valves for small terminal units For modulating control
TBV-CM Combined control & balancing valves for small terminal units For modulating control IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the
AES 28/50/75/110/150 RFG Sterilization Autoclaves with counter pressure and fast cooling
AES 75 RFG Advantages: Total flexibility adjusting the pressures on each cycle phases. Three settable pressures: on heating phase, on sterilizing phase and on cooling phase. Reduces the total cycle time
Reaction apparatus with agitator and double wall vessel 0,1-5 litres
Reaction apparatus with agitator and double wall vessel 0,1-5 litres We deliver the systems without motor, but with manual and certificate. The double cardan coupling enables a tension-free drive of the
Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps
D Alcotest 6510 Breath Alcohol Screening Device Operator Instructions for Use ST-207-2004_sw.eps Contents Contents................................................. 2 For your safety............................................
Product Range. Product Range
Product Range Product Range EXCELLENT SOLUTIONS FOR COMPRESSED AIR With more than 30 years experience in pneumatic field, Aignep is an Italian leading manufacturer of compressed air elements. Aignep is
EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
P r o d u c t i n f o r m at i o n EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total
Pressure is our Business
Pressure is our Business Count on gauges and calibrators that perform Wherever you work Reduce Measurement Error Protect against diminished accuracy from environmental conditions, accidental damage, and
The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times
Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING
Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes
Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes Instruction Bulletin Addendum IB PB1000 Part no. Serial no. Order no. Oxymitter 4000 Applicability: Used with pressure-balancing
Easy to operate even for biginners. Set up the number of test. Possible to select from 1 to times
With a force gauge and attachments, compression/tensile/peeling tests are possible up to 1000N/2500N. It provides consistent testing speed and direction, offering highly accurate test results. MX2-2500N
VIC offers a variety of Calibrated Gas Leaks
CALIBRATED GAS LEAKS VIC offers a high quality line of calibrated gas leaks traceable to National Institute of Standards Technology (NIST). Calibrated gas leaks are used to provide a controlled delivery
Bespoke. Technical. Advice. Solutions. Design. Competence Expertise. Quality. Reliable. Ambitious. Friendly Committed. Helpful
Technical Advice Bespoke Solutions Quality Design Competence Expertise Reliable Ambitious Friendly Committed Helpful Our Company Introduction FTI was formed in 2000 and is one of the UK s premier suppliers
Automatic Isokinetic Sampler. ST5 Evo
Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,
Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM
Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters
Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information attery Powered hermal Mass Flow Meters for Gases icenta Controls Ltd, Unit 3 he Woodford Centre, Lysander Way, Old arum Park, alisbury, P4 6U, U Digital advantage:
Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.
Specialty gases in small cylinders Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders. 02 Specialty gases in small cylinders Our specialty gases guarantee precision.
Precision Mass Flow Meters / Controllers for Liquids and Gases
CORI-FLOW TM Precision Mass Flow Meters / Controllers for Liquids and Gases Introduction Bronkhorst Cori-Tech B.V. manufactures precise, compact Mass Flow Meters and Controllers for gases and liquids,
RB 4700 Commercial & Industrial Regulator
RB 4700 Commercial & Industrial Regulator The RB 4700 regulator is designed for use in industrial and distribution applications such as district station and heating plants, and for industrial customers.
OVERVIEW pg 3. Major Points to Consider pg 3 Minor Points to Consider pg 3. INSTRUCTIONS pg 4
TABLE OF CONTENTS OVERVIEW pg 3 Major Points to Consider pg 3 Minor Points to Consider pg 3 INSTRUCTIONS pg 4 How Does Nordic Freeze Work pg 4 How Long Will the Ice Plug Take to Form pg 4 How Do I Know
Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
STAD. Balancing valves DN 15-50
STAD Balancing valves DN 15-50 IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for use on the
MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400
MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile 2.75 GB 2.75 Expert 090311 We reserve the right to continuously improve our products and make
GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz
GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical
GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide
GRUNDFOS alldos product information Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide Construction and function Modular system Vacuum regulator for direct mounting
SF 6. Gas Handling. DILO. Sustainably tight. Made in Germany
Gas Handling DILO. Sustainably tight. Made in Germany DILO gas handling Zero emissions and maximum gas re-use is our goal For more than 40 years it has been our aim to meet customer requirements for first-class
-Filling rig Type TS150
-Filling rig Type TS150 Linear filling rig (LKF) for filling of gases The linear filling rig TS150 is designed to fill gas cylinders of different sizes up to 10 litres nominal volume. The TS150 rig is
_ pressure transducers. User Manual
_ pressure transducers User Manual summary introduction DescriPTION preliminary checks Installation taking measurements data management Troubleshooting maintenance Appendix 1 Page 4 Page 5 Page 6 Page
MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers
MASS-STREAM TM Instruction Manual D-6200 Analog Mass Flow Meters / Controllers Doc. No.: 9.17.112A Date: 17-03-2017 ATTENTION Before installing and operating the instrument it is strongly recommended that
7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel
KROHNE 04/2003 7.02445.71.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel One tube no limits No limits with tube material No limits with
Holugt Portable Unit HL120 Electric
Holugt Portable Unit HL120 Electric SPECIFICATIONS Capacity (litre per minute) 100 Maximum pressure (bar) 330 Working pressure (bar) 200 or 300 Dimensions (cm) 65x35x39 Weight (kg) 39.5 Sound Level (db)
TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
ANALOX ATA - Trimix Analyser. Technical Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK
ANALOX ATA - Trimix Analyser Technical Manual Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net
6890 GC Site Preparation
6890 GC Site Preparation (a16011) This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this material. The information
PTFE-SINGLE GLASS FLOW METERS
PTFE-SINGLE GLASS FLOW METERS T GENERAL DESCRIPTION Model T fl ow meters incorporate the principles of traditional variable area fl ow technology. PTFE 150mm with MVT TM Valve These rugged PTFE-Glass flow
Dräger OCEANUS 140 Mobile Compressor
Dräger OCEANUS 140 Mobile Compressor The Dräger OCEANUS 140 mobile compressor is designed for operations at sea. Tank Filling tube with filling valve Exhaust Safety valve Air filter Filter system P21 Petrol
Sample C ylinde rs, Acce ssorie s, and O utage Tube s
www.swagelok.com Sample C ylinde rs, cce ssorie s, and O utage s Features Sizes from 10 to 3785 cm 3 (1 gal) Working pressures up to 5000 psig (344 bar) 304L and 316L stainless steel and alloy 400 2 Sample
Operating instructions for variable area flow meter with needle valve. Model: UVR/UTR
Operating instructions for variable area flow meter with needle valve Model: UVR/UTR 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument inspection... 3 4. Regulation use... 3 5. Operating principle...
AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents
AQUARIUS Operating Instructions for the Type 70 Electrolytic Gas Soldering / Welding Unit Table of Contents 1. Important General Remarks 2 2. Safety Instructions 2 3. Description of the Soldering Unit
Let our solutions keep you safely afloat offshore. Reliable gas services from Linde Gas Benelux.
3 Customer 3 Product/Application information Information Let our solutions keep you safely afloat offshore. Reliable gas services from Linde Gas Benelux. 02 Reliable offshore gas services from Linde Gas
Connection solutions for the gas industry Date: 04/2013
Catalogue 20 WEH Connectors Pressure-tight connections in seconds for gaseous applications Connection solutions for the gas industry Date: 04/2013 WEH - We Engineer Hightech All rights reserved, WEH GmbH
PGA3510 Portable 3-Gas IR Analyzer. Operations Manual
PGA3510 Portable 3-Gas IR Analyzer Operations Manual Please read, understand, and follow these instructions before operating this equipment. Super Systems, Inc. is not responsible for damages incurred
Using Vaporized Hydrogen Peroxide
for Bio-Decontamination D-111046-2013 Using Vaporized Hydrogen Peroxide In 1994, Dräger introduced the first electrochemical hydrogen peroxide (H2O2) sensor for monitoring low concentrations of vaporized
Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases
Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No
Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.
Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up
User Manual. Quantos Automated Dosing Powder Module
User Manual Powder Module 1 Introduction Thank you for purchasing the Quantos dosing system. Quantos is based on the renowned and reliable XPE series balances from METTLER TOLEDO. Besides the highly accurate
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information attery owered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized by