1 Pressure maintenance systems with compressors Compresso Pressure maintenance systems with compressors Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING AVANTAGE Compresso is a precision pressurisation system with compressors for heating, solar and chilled water systems. It is especially suitable in situations where compactness and precision are required. The system capacity range lies between pressurisation with Statico and Transfero.

2 Pressure maintenance systems WiTh ComPressors - CompREsso Technical description Control unit Tecox Applications: eating, solar and chilled water systems. For systems according to EN 12828, solar systems according to EN 12976, ENV with on-site excess temperature protection in case of power blackout. media: Non-aggressive and non-toxic system media. Addition of antifreeze agent up to 50%. pressure: Min. admissible pressure, PSmin: 0 bar Max. admissible pressure, PS: see Articles Temperature: Max. admissible temperature, TS: 70 C Min. admissible temperature, TSmin: 5 C Max. admissible ambient temperature, TU: 40 C Min. admissible ambient temperature, TUmin: 5 C Max. admissible temperature for water make-up, TW: 30 C (CPV, CPV...C) Accuracy: Precision pressure maintenance ±0,1 bar. supply voltage: 230 V/50 z Electric load: See Articles. Enclosure class: IP according to EN IP 22 (C 10...F, CPV, CPV...C) IP 54 (C 20, CX) sound pressure level: 59 d(a) (C 10...F, CPV, CPV...C) 64 d(a) (C 20) material: In essence: steel, brass and bronze Function, Equipment, Features: - raincube control. Self-optimising with memory function. - Silentrun operation. Particularly silent. Pressure-optimised start mode. - Fillsafe water make-up monitoring. With possibility to control water make-up through a Pleno P. With contact water meter and a break tank type A according to EN 1717, SVGW-tested (CPV, VPV...C). - igh quality metal cover (C...F) with handles (C10, C20, CPV, CPV...C). - Floor standing (C10, C20, CPV, CPV...C). - Variable installation in front of (C10, C20) or next to (C10, C20, CPV, CPV...C) the primary vessel. - Space-saving assembly on the CU or CG primary vessel up to 800 litres, PS 6 bar (C 10...F). - With integrated wall mounting bracket (CX). - Including assembly kit for the air-side connection of the Tecox with the primary vessel. Addition for CpV - Vacusplit spray-type degassing of the system and make-up water in a vacuum vessel. - Eco-interval operation for interval degassing and continuous degassing. - Cooling version insulated and vapor sealed (CPV...C). - Isolating valves to the system. Transportation and storing: In frostless, dry places. Approvals: CE-tested according to the requirements of the European irectives PE/EP 97/23/EC, 2004/108/EC, 2006/95/EC. 2

3 Pressure maintenance systems WiTh ComPressors - CompREsso Technical description Expansion vessels Applications: Only together with Control unit Tecox. See Applications under Technical description - Control unit Tecox. media: Non-aggressive and non-toxic system media. Addition of antifreeze agent up to 50%. pressure: Min. admissible pressure, PSmin: 0 bar Max. admissible pressure, PS: see Articles Temperature: Max. admissible temperature, TS: 120 C Min. admissible temperature, TSmin: -10 C Max. admissible bag temperature, T: 70 C Min. admissible bag temperature, Tmin: 5 C material: Steel. Color beryllium. Airproof butyl bag according to EN Function, Equipment, Features: - ag can be vented at the top, condensate drain at the bottom. - Sinus ring for upright assembly (CU, CU...E). Feet for upright assembly (CG, CG...E). - Airproof butyl bag (CU, CU...E, CG, CG...E), exchangeable (CG, CG...E). - Endoscopic inspection opening for internal inspections (CU, CU...E). Two flange openings for internal inspections (CG, CG...E). - Corrosion-protected internal coating for minimum bag wear (CG, CG...E). - Including flex tube for the water-side connection and lock shield valve with ball valve for fast draining (CU, CG). - Including assembly kit for the air-side connection of the vessels and lock shield valve for the water-side connection with ball valve for fast draining (CU...E, CG...E). Transportation and storing: In frostless, dry places. Approvals: CE design-tested according to PE/EP 97/23/EC. Warranty: Compresso CG, CG...E: 5-year warranty for the airproof butyl bag. Compresso CU, CU...E: 5-year warranty for the vessel. 3

4 Pressure maintenance systems WiTh ComPressors - CompREsso Control unit Tecox, Compresso C 10 Articles Compresso C 10.1 F Precision pressure maintenance ± 0.1 bar 1 compressor. Valve mainfold with 1 spill valve and saftey valve. ps T pa C F , C F 3, , C F , C F , C F , Compresso C 10.1 Precision pressure maintenance ± 0.1 bar 1 compressor. Valve manifold with 1 spill valve and safety valve. ps T pa C , C , , C , , C , C , Compresso C 10.2 Precision pressure maintenance ± 0.1 bar 2 compressors. Valve manifold with 2 spill valves and safety valve. Switching is time and load dependant. ps T pa C , C , , C , , C , C , T = epth of the device 4

5 Pressure maintenance systems WiTh ComPressors - CompREsso Control unit Tecox, Compresso CpV Articles front back Compresso CpV 10.1 Precision pressure maintenance ± 0.1 bar. Water make-up. egassing. 1 compressor. Valve manifold with 1 spill valve and safety valve. Connections: in (SE) Rp1, out (SA) Rp1, water make-up (SNS) Rp1/2. SA SE SNS ps T pp VNs [l/h] pa CPV ,5-2, , CPV , ,5-3, , CPV , ,5-3, , CPV ,5-4, , front back Compresso CpV 10.1 C, Cooling version Insulated and vapor sealed. Precision pressure maintenance ± 0.1 bar. Water make-up. egassing. 1 compressor. Valve manifold with 1 spill valve and safety valve. Connections: in (SE) Rp1, out (SA) Rp1, water make-up (SNS) Rp1/2. SA SE SNS ps T pp VNs [l/h] pa CPV C ,5-2, , CPV C ,5-3, , CPV C ,5-3, , CPV C ,5-4, , T = epth of the device 5

6 Pressure maintenance systems WiTh ComPressors - CompREsso Control unit Tecox, Compresso C 20 Articles Compresso C 20.1 Precision pressure maintenance ± 0.1 bar 1 compressor. Valve manifold with 1 spill valve and safety valve. With sound absorbing case. ps T pa C , C , Compresso C 20.2 Precision pressure maintenance ± 0.1 bar 2 compressors. Valve manifold with 2 spill valves and safety valve. Switching is time and load dependant. Consists of primary and extension module each with sound absorbing case. ps 1 T pa C , C , Compresso CX Precision pressure maintenance ± 0.1 bar For oil-free external compressed air. 1 air inlet and 1 air exit valve ps T pa CX , CX , CX , T = epth of the device 6

7 Pressure maintenance systems WiTh ComPressors - CompREsso Expansion vessels Compresso CU Primary vessel. Measuring foot for content measurement. Including flex tube for the water-side connection and lock shield valve with ball valve for fast draining. VN [l] s sw 6 bar (ps) CU Rp1 G3/ CU Rp1 G3/ CU Rp1 G3/ CU Rp1 G3/ CU Rp1 G3/ CU Rp1 G3/ S SW Compresso CU...E Secondary vessel. Including flex tube for the water-side connection and lock shield valve with ball valve for fast draining, assembly kit for the air-side connection of the vessels. VN [l] s sw 6 bar (ps) CU E Rp1 G3/ CU E Rp1 G3/ CU E Rp1 G3/ CU E Rp1 G3/ CU E Rp1 G3/ CU E Rp1 G3/ S SW 7

8 Pressure maintenance systems WiTh ComPressors - CompREsso Compresso CG Primary vessel. Measuring foot for content measurement. S SW S SW l l * VN [l] ** s sw 6 bar (ps) CG Rp1 G3/ CG Rp1 G3/ CG Rp1 G3/ CG Rp1 1/2 G3/ CG Rp1 1/2 G3/ CG Rp1 1/2 G3/ CG Rp1 1/2 G3/ CG Rp1 1/2 G3/ CG Rp1 1/2 G3/ bar (ps) CG Rp1 G3/ CG Rp1 G3/ CG Rp1 G3/ CG Rp1 1/2 G3/ CG Rp1 1/2 G3/ CG Rp1 1/2 G3/ CG Rp1 1/2 G3/ CG Rp1 1/2 G3/ CG Rp1 1/2 G3/

9 Pressure maintenance systems WiTh ComPressors - CompREsso Compresso CG...E Secondary vessel. S S SW SW l l * VN [l] ** s sw 6 bar (ps) CG 300.6E Rp1 G3/ CG 500.6E Rp1 G3/ CG 700.6E Rp1 G3/ CG E Rp1 1/2 G3/ CG E Rp1 1/2 G3/ CG E Rp1 1/2 G3/ CG E Rp1 1/2 G3/ CG E Rp1 1/2 G3/ CG E Rp1 1/2 G3/ bar (ps) CG E Rp1 G3/ CG E Rp1 G3/ CG E Rp1 G3/ CG E Rp1 1/2 G3/ CG E Rp1 1/2 G3/ CG E Rp1 1/2 G3/ CG E Rp1 1/2 G3/ CG E Rp1 1/2 G3/ CG E Rp1 1/2 G3/ *) Applications > 10 bar and special vessels upon request. **) Tolerance 0 /

10 Pressure maintenance systems WiTh ComPressors - CompREsso Accessories for control modules Communication module for raincube control Max. admissible ambient temperature, TU: 40 C Enclosure class: IP 54 Supply voltage: 230 V/50 z ComCube C RS 485 interface for communicating with raincube, 6 digital inputs for the use of external volt free signals (NO), 9 volt free digital outputs, freely programmable; all outputs can be inversed. Wall mounted, fixing elements for cable management. T pa C ,5 0, ComCube CA 2 separated analoge outputs 4-20 ma for connection to MS, isolation voltage 2.5 kvac. All cabeling inside the casing, wall mounted. T pa CA ,5 0, T = epth of the device software expansion Usage options as Master / Slave, parallel, expanded capacity or 100% redundancy. Remote switching of Master / Slave possible. Cabeling on site, commissioning by Pneumatex Service. Including assembly kit with shut-offs for the air-side connection of the Tecoxes with the primary vessel. master-slave ms 2 parallel operation of 2 Compresso C 10, C 20. MS 2 C master-slave ms 3 parallel operation of 3 Compresso C 10, C 20. MS 3 C master-slave ms 4 parallel operation of 4 Compresso C 10, C 20. MS 4 C Additional information: system design: atasheet Planning and calculation. Online calculation: Software SelectP! Abbrevations and terminology: atasheet Planning and calculation. 10

11 Pressure maintenance systems WiTh ComPressors - CompREsso 11

12 Pressure maintenance systems WiTh ComPressors - CompREsso The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by TA ydronics without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit

13 Pressure control and water make up system Pleno Pressure control and water make up system Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING AVANTAGE Pressure-maintaining monitoring device in the sense of EN The Pleno ensures that the water reserve required for optimum functioning of the expansion vessels is given at all times. If the level drops below the minimum, water is automatically added to the system. The «fillsafe» electronically monitors and controls the water make-up and ensures maximum safety.

14 Pressure ConTrol and WaTer make up system - PlENo Technical description Application: eating, solar and chilled water systems. For systems according to EN 12828, EN 12976, ENV 12977, EN 12952, EN Media: Entry: fresh water Outflow(Consumer side): Non-aggressive and non-toxic system media. Addition of antifreeze agent up to 50%. Pressure: Mini. admissible pressure, PSmin: 0 bar Temperature: Max. admissible temperature, TS: 65 C (P, PI), 30 C (PI 6, PI 9) Min. admissible temperature, TSmin: 0 C Max. admissible ambient temperature, TU: 40 C Supply voltage: 230 V/50 z Enclosure class: Pleno P: IP 65 Pleno PI: IP 54 Function, Equipment, Features - raincube control. Self-optimising with memory function (PI, PI 6, PI 9). - Fillsafe water make-up. Pressure-dependent. For pressure expansion vessels with fixed air cushion, i.e. Statico (PI). - Fillsafe water make-up. Pressure- or level-dependent. For pressure expansion vessels, i.e. Statico or pressuremaintaining stations, i.e. Compresso. - External control from pressure-maintaining or degassing stations, i.e. Compresso, Transfero or Vento (P, PI 6, PI 9). - With contact water meter and back flow preventer type A according to EN 1717, VGW, SVGW, KIWA N.V., ELGAQUA, WRAS and ACS tested (P, PI). - With contact water meter and a break tank type A according to EN 1717, SVGW-tested (PI 6, PI 9). - With integrated wall mounting bracket (P, PI, PI 9) - Floor standing (PI 6). Approvals: Pleno PI (without pumps): CE-tested according to the requirements of the European irectives 2004/108/EC, 2006/95/EC. Pleno PI (with pumps): CE-tested according to the requirements of the European irectives PE/EP 97/23/EC, 2004/108/EC, 2006/95/EC. Material: Pleno PI 9.1: igh quality metal cover. Pleno PI 6.1, 6.2: igh quality metal cover with handles. 2

15 Pressure ConTrol and WaTer make up system - PlENo iagrams Approx. throughput V, Pleno P / PI The requirements for pns must be taken into account for Statico and Compresso: Pleno P: Required fresh water pressure Compresso: pns P0 (raincube) + 1,9 bar, pns 10 bar Pleno P/PI: Required fresh water pressure Statico: pns P0 (raincube) + 1,7 bar, pns 10 bar. 3

16 Pressure ConTrol and WaTer make up system - PlENo Control unit Tecox, Pleno P Articles Pleno P ydraulic unit. Water make-up without pumps. Connection out (SA): G1/2. Connection water make-up (SNS): G1/2. PS T Kvs P ,02 0, Control unit Tecox, Pleno PI Articles Pleno PI Control unit Tecox. Water make-up without pumps. Connection out (SA): G1/2. Connection water make-up (SNS): G1/2. PS T Kvs PI ,04 0, Control unit Tecox, Pleno PI 9 Articles front back SA SNS Pleno PI 9.1 Control unit Tecox. Water make-up with pump with filling function. 1 pump with integrated wall mounting bracket. Connection out (SA): Rp3/4. Connection water make-up (SNS): Rp1/2. PS T SPl [d(a)] Pp VNS [l/h] PI , T = epth of the device 4

17 Pressure ConTrol and WaTer make up system - PlENo Control unit Tecox, Pleno PI 6 Articles Pleno PI 6.1 Control unit Tecox. Water make-up with pump with filling function. 1 pump. Floor standing. Inclusive of flexible hose for inlet. Connection out (SA): Rp3/4. Connection water make-up (SNS): Rp1/2. SA front back SNS PS T SPl [d(a)] Pp VNS [l/h] PI , , Pleno PI 6.2 Control unit Tecox. Water make-up with pumps with filling function. 2 pumps. Including a reserve pump. Floor standing. Inclusive of flexible hose for inlet. Connection out (SA): Rp3/4. Connection water make-up (SNS): Rp1/2. SA front back SNS PS T SPl [d(a)] Pp VNS [l/h] PI , , T = epth of the device 5

18 Pressure ConTrol and WaTer make up system - PlENo Accessories for control modules Communication module for raincube control Max. admissible ambient temperature, TU: 40 C Enclosure class: IP 54 Supply voltage: 230 V/50 z ComCube C RS 485 interface for communicating with raincube, 6 digital inputs for the use of external volt free signals (NO), 9 volt free digital outputs, freely programmable; all outputs can be inversed. Wall mounted, fixing elements for cable management. T C ,5 0, ComCube CA 2 separated analoge outputs 4-20 ma for connection to MS, isolation voltage 2.5 kvac. All cabeling inside the casing, wall mounted. T CA ,5 0, T = epth of the device Additional information System design: Online calculation software SelectP! Abbrevations and terminology: atasheet Planning and calculation. Glossary. Accessories for control modules: Communication module. The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by TA ydronics without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit

19 Expansion vessels with fixed air cushion Statico Expansion vessels with fixed air cushion Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING AVANTAGE Statico is the product name for pressure expansion vessels with fixed gas charge for heating, solar and cooling water systems. It s brilliantly simple design, robust construction and operation without auxiliary power make it one of the most used pressure maintenance devices in the lower performance range.

20 ExPansion vessels WiTh fixed air Cushion - STATIco Technical description Applications: eating, solar and chilled water systems. Media: Non-aggressive and non-toxic system media. Addition of antifreeze agent up to 50%. Pressure: Min. admissible pressure, PSmin: 0 bar Max. admissible pressure, PS: see Articles Temperature: Max. admissible temperature, TS: 120 C Min. admissible temperature, TSmin: -10 C Max. admissible bag temperature, T: 70 C Min. admissible bag temperature, Tmin: 5 C Material: Steel. Color beryllium. Lock shield valve LV: rass Function, Equipment, Features: - Airproof butyl bag according to EN Airproof butyl bag according to EN 13831, exchangeable (SG). - Sinus ring for upright assembly and easy transport (SU). Feet for upright assembly (SG). Wall bracket for easy assembly (S). - Installation with bottom, side or top connection. From 80 litres with bottom or side connection (S). Transportation and storing: In frostless, dry places. Approvals: CE design-tested according to PE/EP 97/23/EC. Warranty: Statico S, SU: 5-year warranty for the vessel. Statico SG: 5-year warranty for the airproof butyl bag. 2

21 ExPansion vessels WiTh fixed air Cushion - STATIco Articles Statico S iscus shaped VN [l] P0 S S 3 bar (PS) S ,5 R1/ S ,7 R1/ S ,1 R3/ S R3/ S ,4 R3/ S , R3/ S , ,7 R3/ bar (PS) S ** 4,0 R1/ S ** 5,1 R1/ S ** 6,5 R3/ S ** 8 R3/ S ** 9,7 R3/ S ** 12 R3/ S ** 16 R3/ **) Tolerance 0 /+35 Statico SU Slim, cylindrical model VN [l] P0 S S 3 bar (PS) SU , R3/ SU , R3/ SU , R3/ SU , R3/ SU , R3/ SU , R3/ SU , R3/ bar (PS) SU , R3/ SU , R3/ SU , R3/ SU , R3/ SU , R3/ SU , R3/ SU , R3/ bar (PS) SU R3/ SU R3/ SU R3/ SU R3/ SU R3/ SU R3/ Accessories: Lock shield valve LV Intermediate vessel see datasheet Accessories 3

22 ExPansion vessels WiTh fixed air Cushion - STATIco Statico SG Slim, cylindrical model * VN [l] P0 ** S 6 bar (PS) SG , R1 1/ SG , R1 1/ SG , R1 1/ SG , R1 1/ SG , R1 1/ SG , R1 1/ bar (PS) SG R1 1/ SG R1 1/ SG R1 1/ SG R1 1/ SG R1 1/ SG R1 1/ *) Applications > 10 bar and special vessels upon request. **) Tolerance 0 /-100. Accessories: Intermediate vessel see datasheet Accessories Accessories for pressure maintenance Maintenance and disassembly of expansion vessels. Can only be closed with an allen key which is include in the supply, ball valve with N 15 hose connection for fast draining. Lock shield valve LV Female thread on both sides, screw connection on the vessel connection side. PS L S SG SW LV ,7 Rp3/4 Rp1/2 G3/ Lock shield valve LV Female thread on both sides, flat sealing union for direct connection to all suitable expansion vessels. PS L S SG SW LV ,6 Rp3/4 G3/4 G3/ LV ,7 Rp1 G1 G3/ SG connection set LV A Female thread on both sides, 90 bend with threaded seal for direct connection to Statico SU expansion vessels. L SW PS L S SG SW LV 20 A ,8 Rp3/4 Rp3/4 G3/ S Additional information: System design: atasheet Planning and calculation. Online calculation: Software SelectP! Abbrevations and terminology: atasheet Planning and calculation. The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by TA ydronics without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit EN

23 Pressure maintenance system with pumps Transfero T_ Pressure maintenance systems up to 10 MW with pumps Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING AVANTAGE Pneumatex Transfero T_ is a precision pressure maintenance device up to 10 MW with pumps for heating, solar and chilled water systems. Its use is particularly recommended where high performance, compact design and precision are required. In the medium performance range with tight budgets, they can also be used as combination devices with integrated degassing and water make-up.

24 Pressure maintenance system WiTh PumPs - TRANsfERo T_ Technical description Control unit Tecox Applications: eating, solar and chilled water systems. For systems according to EN 12828, solar systems according to EN 12976, ENV with on-site excess temperature protection in case of power blackout. Media: Non-aggressive and non-toxic system media. Addition of antifreeze agent up to 50%. Pressure: Min. admissible pressure, PSmin: 0 bar Max. admissible pressure, PS: see Articles Temperature: Max. admissible temperature, TS: 70 C Min. admissible temperature, TSmin: 0 C Max. admissible ambient temperature, TU: 40 C Min. admissible ambient temperature, TUmin: 5 C Max. admissible temperature for water make-up, TW: 30 C (TP, TPV, TPV...P) Accuracy: Precision pressure maintenance ±0,2 bar. supply voltage: 230 V/50 z (T, TP, TV, TPV) 3x400/50 or 3x400/60 (TPV...P), see Articles. Enclosure class: IP 54 according to EN Material: In essence: steel, brass and bronze function, Equipment, features: - raincube control. Self-optimising with memory function. - ynaflex operation. Elastic, speed-controlled operation (T, TP, TV, TPV). 2 pressure accumulator vessels for optimum pressure maintenance (TPV...P). - Fillsafe water make-up monitoring with possibility to control water make-up through a Pleno P (T, TV). With contact water meter and a break tank type A according to EN 1717, SVGW-tested (TP, TPV, TPV...P). - Oxystop degassing of the system and make-up water under partial vacuum (TV, TPV). - Protected isolating valves to the system. - Variable installation next to the primary vessel. - igh quality metal cover (T, TP, TV, TPV, TPV...P) with handles (T, TP, TV, TPV). - Including convoluted stainless steel hoses with seals for the connection of the primary vessel. Transportation and storing: In frostless, dry places. Approvals: CE-tested according to the requirements of the European irectives PE/EP 97/23/EC, 2004/108/EC, 2006/95/EC. 2

25 Pressure maintenance system WiTh PumPs - TRANsfERo T_ Technical description Expansion vessels Applications: Only together with Control unit Tecox. See Applications under Technical description - Control unit Tecox. Media: Non-aggressive and non-toxic system media. Addition of antifreeze agent up to 50%. Pressure: Min. admissible pressure, PSmin: 0 bar Max. admissible pressure, PS: 2 bar Temperature: Max admissible temperature, TS: 120 C Min. admissible temperature, TSmin: -10 C Max. admissible bag temperature, T: 70 C Min. admissible bag temperature, Tmin: 5 C Material: Steel. Color beryllium. Airproof butyl bag according to EN and Pneumatex internal standard. Transportation and storing: In frostless, dry places. Approvals: CE design-tested according to PE/EP 97/23/EC. function, Equipment, features - ag can be vented at the top, condensate drain at the bottom. - Sinus ring for upright assembly (TU, TU...E). Feet for upright assembly (TG, TG...E). - Airproof butyl bag (TU, TU...E, TG, TG...E), exchangeable (TG, TG...E). - Endoscopic inspection opening for internal inspections (TU, TU...E). Two flange openings for internal inspections (TG, TG...E). Warranty: Transfero TU, TU...E: 5-year warranty for the vessel. Transfero TG, TG...E: 5-year warranty for the airproof butyl bag. 3

26 Pressure maintenance system WiTh PumPs - TRANsfERo T_ Control unit Tecox, Transfero T Articles Transfero T.1 Precision pressure maintenance ±0,2 bar. 1 pump. 1 spill valve. Variable installation in front of or next to the primary vessel. Connections: in (SE) Rp1, out (SA) Rp1, water make-up (SNS) Rp1/2, vessel (SG) R1. T spl [d(a)] SE SG front back SA SNS 8 bar (Ps) T , T , bar (Ps) T , T , Transfero T.2 Precision pressure maintenance ±0,2 bar. 2 pumps. 2 spill valves. Switching is time and load dependant. Variable installation next to the primary vessel. Connections: in (SE) Rp1 1/4, out (SA) Rp1 1/4, water make-up (SNS) Rp1/2, vessel (SG) R1 1/4. T spl [d(a)] SA SG SNS front back SE 8 bar (Ps) T , T , bar (Ps) T T Accessories for control modules: Communication module. Master-Slave. Accessories for pressure maintenance: Intermediate vessel. atasheet Accessories. Control unit Tecox, Transfero TP Articles Transfero TP.1 Precision pressure maintenance ±0,2 bar. Water make-up. 1 pump. 1 spill valve. Variable installation in front of or next to the primary vessel. Connections: in (SE) Rp1, out (SA) Rp1, water make-up (SNS) G1/2, vessel (SG) R1. T spl [d(a)] SE SG front back SA SNS 8 bar (Ps) TP , TP , bar (Ps) TP , TP , T = epth of the device 4

27 Pressure maintenance system WiTh PumPs - TRANsfERo T_ Transfero TP.2 Precision pressure maintenance ±0,2 bar. Water make-up. 2 pumps. 2 spill valves. Switching is time and load dependant. Variable installation next to the primary vessel. Connections: in (SE) Rp1 1/4, out (SA) Rp1 1/4, water make-up (SNS) G1/2, vessel (SG) R1 1/4. T spl [d(a)] SA SG front back SNS SE 8 bar (Ps) TP , TP , bar (Ps) TP TP Accessories for control modules: Communication module. Master-Slave. Accessories for pressure maintenance: Intermediate vessel. atasheet Accessories. Control unit Tecox, Transfero TV Articles Transfero TV.1 Precision pressure maintenance ±0,2 bar. egassing. 1 pump. 1 spill valve. Variable installation in front of or next to the primary vessel. Connections: in (SE) Rp1, out (SA) Rp1, water make-up (SNS) Rp1/2, vessel (SG) R1. T spl [d(a)] SE SG front back SA SNS 8 bar (Ps) TV , TV , bar (Ps) TV , TV , Transfero TV.2 Precision pressure maintenance ±0,2 bar. egassing. 2 pumps. 2 spill valves. Switching is time and load dependant. Variable installation next to the primary vessel. Connections: in (SE) Rp1 1/4, out (SA) Rp1 1/4, water make-up (SNS) Rp1/2, vessel (SG) R1 1/4. T spl [d(a)] SA SG SNS front back SE 8 bar (Ps) TV , TV , bar (Ps) TV TV Accessories for control modules: Communication module. Master-Slave. T = epth of the device 5

28 Pressure maintenance system WiTh PumPs - TRANsfERo T_ Control unit Tecox, Transfero TPV Articles Transfero TPV.1 Precision pressure maintenance ±0,2 bar. Water make-up. egassing. 1 pump. 1 spill valve. Variable installation in front of or next to the primary vessel. Connections: in (SE) Rp1, out (SA) Rp1, water make-up (SNS) G1/2, vessel (SG) R1. T spl [d(a)] SE SG front back SA SNS 8 bar (Ps) TPV , TPV , bar (Ps) TPV , TPV , Transfero TPV.2 Precision pressure maintenance ±0,2 bar. Water make-up. egassing. 2 pumps. 2 spill valves. Switching is time and load dependant. Variable installation next to the primary vessel. Connections: in (SE) Rp1 1/4, out (SA) Rp1 1/4, water make-up (SNS) G1/2, vessel (SG) R1 1/4. T spl [d(a)] SA front back SNS SE 8 bar (Ps) TPV , TPV , bar (Ps) TPV TPV Accessories for control modules: Communication module. Master-Slave. Control unit Tecox, Transfero TPV...P Articles front back SNS Transfero TPV.2 P Precision pressure maintenance ±0,2 bar. Water make-up. egassing. 2 pressure accumulator vessels for optimum pressure maintenance. 2 pumps. 2 spill valves. Switching is time and load dependant. Connections: in (SE) Rp1 1/4, out (SA) Rp1 1/4, water make-up (SNS) G1/2, vessel (SG) R1 1/4. T U [V/z] spl [d(a)] SA SE SG 16 bar (Ps) TPV19.2 P ,0 3x400/50 < TPV P ,6 3x400/60 < T = epth of the device 6

29 Pressure maintenance system WiTh PumPs - TRANsfERo T_ Expansion vessels, Transfero TU/TU...E - Articles Transfero TU Primary vessel. Measuring foot for content measurement. Including assembly kit for the water-side connection with 2 bar safety valve and ball valve for fast draining. VN [l] s sw 2 bar (Ps) TU R1 1/4 G3/ TU R1 1/4 G3/ TU R1 1/4 G3/ TU R1 1/4 G3/ TU R1 1/4 G3/ TU R1 1/4 G3/ S Transfero TU...E Secondary vessel. Including assembly kit for the water-side connection, flexible hose and lock shield valve with ball valve for fast draining. VN [l] s sw 2 bar (Ps) TU 200 E R1 1/4 G3/ TU 300 E R1 1/4 G3/ TU 400 E R1 1/4 G3/ TU 500 E R1 1/4 G3/ TU 600 E R1 1/4 G3/ TU 800 E R1 1/4 G3/ S 7

30 Pressure maintenance system WiTh PumPs - TRANsfERo T_ Expansion vessels, Transfero TG/TG...E - Articles Transfero TG Primary vessel. Measuring foot for content measurement. Including assembly kit for the water-side connection with 2 bar safety valve and ball valve for fast draining. * VN [l] ** s sw 2 bar (Ps) TG R1 1/4 G3/ TG R1 1/4 G3/ TG R1 1/4 G3/ TG R1 1/4 G3/ TG R1 1/4 G3/ TG R1 1/4 G3/ Transfero TG...E Secondary vessel. Including flexible hose for the water-side connection and lock shield valve with ball valve for fast draining. * VN [l] ** s sw 2 bar (Ps) TG 1000 E G1 1/4 G3/ TG 1500 E G1 1/4 G3/ TG 2000 E G1 1/4 G3/ TG 3000 E G1 1/4 G3/ TG 4000 E G1 1/4 G3/ TG 5000 E G1 1/4 G3/ *) Special vessel upon request. **) Tolerance 0 /

31 Pressure maintenance system WiTh PumPs - TRANsfERo T_ Accessories for control modules Communication module for raincube control Max. admissible ambient temperature, TU: 40 C Enclosure class: IP 54 Supply voltage: 230 V/50 z ComCube C RS 485 interface for communicating with raincube, 6 digital inputs for the use of external volt free signals (NO), 9 volt free digital outputs, freely programmable; all outputs can be inversed. Wall mounted, fixing elements for cable management. T C ,5 0, ComCube CA 2 separated analoge outputs 4-20 ma for connection to MS, isolation voltage 2.5 kvac. All cabeling inside the casing, wall mounted. T CA ,5 0, T = epth of the device software expansion Usage options as Master / Slave, parallel, expanded capacity or 100% redundancy. Remote switching of Master / Slave possible. Cabeling on site, commissioning by Pneumatex Service. Master-slave Ms 2 Parallel operation of 2 Transfero T_ Including assembly kit with 1 safety valve for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels. MS 2 T Master-slave Ms 3 Parallel operation of 3 Transfero T_ Including assembly kit with 2 safety valves for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels. MS 3 T

32 Pressure maintenance system WiTh PumPs - TRANsfERo T_ Master-slave Ms 4 Parallel operation of 4 Transfero T_ Including assembly kit with 3 safety valves for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels. MS 4 T Additional information: system design: atasheet Planning and calculation. Online calculation: Software SelectP! Abbrevations and terminology: atasheet Planning and calculation. 10

33 Pressure maintenance system WiTh PumPs - TRANsfERo T_ 11

34 Pressure maintenance system WiTh PumPs - TRANsfERo T_ The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by TA ydronics without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit

35 Pressure maintenence systems with pumps Transfero TI Pressure maintenance systems up to 40 MW with pumps Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING AVANTAGE Pneumatex Transfero TI is a precision pressure maintenance device up to 40 MW with pumps for heating, solar and chilled water systems. Its use is particularly recommended where high performance, compact design and precision are required.

36 Pressure maintenence systems WiTh PumPs - TRANsfERo TI Technical description Control unit Tecox Applications: eating, solar and chilled water systems. For systems to EN and optional >110 C to EN 12952, EN with additional pressure limiters Paz PMIN and content indicators Liz IA, solar systems according to EN 12976, ENV with on-site excess temperature protection in case of power blackout. Media: Non-aggressive and non-toxic system media. Addition of antifreeze agent up to 50%. Pressure: Min. admissible pressure, PSmin: 0 bar Max. admissible pressure, PS: see Articles Temperature: Max. admissible temperature, TS: 90 C Min. admissible temperature, TSmin: 0 C Max. admissible ambient temperature, TU: 40 C Min. admissible ambient temperature, TUmin: 5 C Accuracy: Precision pressure maintenance ±0,2 bar. supply voltage: Main current: 3x 400V / 50z (3P + PE) Control voltage: 230V / 50z (P + N + PE) Enclosure class: IP 54 Material: In essence: steel, brass and bronze function, Equipment, features: - 2 pumps. 2 spill connections each with 2 in series connected spill valves. Switching is time and load dependent. - Fillsafe water make-up monitoring. With possibility to control water make-up through a Pleno P. - raincube control. Self-optimising with memory function. - Protected isolating valves for safe isolation. - PowerCube panel PC1. Mains isolator with emergency off; 2 motor protection switches; soft start and soft stop automatic for each pump. - igh quality, solid, galvanized base. - Variable installation in front of or next to the primary vessel. - Inclusive of SV...G safety valves for vessel protection. Connections: Water make-up (SNS): Rp3/4 Connection vessel (SG): 80/6 N/PN Approvals: CE-tested according to the requirements of the European irectives PE/EP 97/23/EC, 2004/108/EC, 2006/95/EC. 2

37 Pressure maintenence systems WiTh PumPs - TRANsfERo TI Technical description Expansion vessels Applications: Only together with Control unit Tecox. See Applications under Technical description - Control unit Tecox. Transfero TGI: Water level limiter only in combination with Liz IA content indicator with Transfero TI to EN and EN Media: Non-aggressive and non-toxic system media. Addition of antifreeze agent up to 50%. Pressure: Min. admissible pressure, PSmin: 0 bar Max. admissible pressure, PS: 2 bar Temperature: Max. admissible temperature, TS: 120 C Min. admissible temperature, TSmin: -10 C Max. admissible bag temperature, T: 70 C Min. admissible bag temperature, Tmin: 5 C Material: Steel, welded. Color beryllium. function, Equipment, features: - Airproof butyl bag according to EN 13831, exchangeable. - ag can be vented at the top, condensate drain at the bottom. - Feet for upright assembly. - Including flexible hose for the water-side connection and lock shield valve with ball valve for fast draining. - Two flange openings for internal inspections. Approvals: CE design-tested according to PE/EP 97/23/EC. Warranty: 5-year warranty for the vessel. 5-year warranty for the airproof butyl bag. 3

38 Pressure maintenence systems WiTh PumPs - TRANsfERo TI Control unit Tecox Transfero TI Connection vessel (SG): N 80 / PN 6 Connection water make-up (SNS): Rp 3/4 SG S 1100 x 1100 * Ps s [N/PN] spl [d(a)] TI 90.2 PC /40 3,0 < TI PC /40 3,8 < TI PC /40 5,4 < TI PC /40 5,4 < TI PC /40 7,2 < TI 61.2 PC /16 3,0 < TI 91.2 PC /16 4,2 < TI PC /16 5,4 < TI PC /16 7,2 < TI PC /40 9,4 < TI PC /40 12,4 < TI 62.2 PC /16 5,4 < TI PC /16 7,2 < TI PC /16 9,4 < TI PC /40 12,4 < TI PC /40 16, *) Constructions TI..3.2 and special installations upon request. Accessories for control modules: Communication module. Additional equipment: Pressure limiter Paz PMIN and content indicator Liz IA. Master-Slave. 4

39 Pressure maintenence systems WiTh PumPs - TRANsfERo TI Expansion vessels Transfero TGI Primary vessel. Measuring foot for content measurement. * VN [l] ** s sw 2 bar (Ps) TGI G1 1/2 G3/ TGI G1 1/2 G3/ TGI G1 1/2 G3/ TGI G1 1/2 G3/ TGI G1 1/2 G3/ TGI G1 1/2 G3/ Transfero TGI...E Secondary vessel. * VN [l] ** s sw 2 bar (Ps) TGI 1000E G1 1/2 G3/ TGI 1500E G1 1/2 G3/ TGI 2000E G1 1/2 G3/ TGI 3000E G1 1/2 G3/ TGI 4000E G1 1/2 G3/ TGI 5000E G1 1/2 G3/ Transfero TGI... Primary vessel. 1 measuring foot for content measurement, 1 measuring foot for water level limiter. * VN [l] ** s sw 2 bar (Ps) TGI G1 1/2 G3/ TGI G1 1/2 G3/ TGI G1 1/2 G3/ TGI G1 1/2 G3/ TGI G1 1/2 G3/ TGI G1 1/2 G3/ *) Special vessel upon request. **) Tolerance 0 /-100. Additional equipment: Pressure limiter Paz PMIN and content indicator Liz IA. 5

40 Pressure maintenence systems WiTh PumPs - TRANsfERo TI Accessories for control modules Communication module. factory fitted to Transfero TI. Max. admissible ambient temperature, TU: 40 C Enclosure class: IP 54 Supply voltage: 230 V/50 z ComCube C TI RS 485 interface for communicating with raincube, 6 digital inputs for the use of external volt free signals (NO), 9 volt free digital outputs, freely programmable; all outputs can be inversed. Complete connections of all in and outputs with connectors of the PowerCube panel. T C TI ,5 0, ComCube CA TI 2 separated analoge outputs 4-20 ma for connection to MS, isolation voltage 2.5 kvac. Connected via mounting rail in the PowerCube panel. T CA TI 17, ,2 0, T = epth of the device software expansion Usage options as Master / Slave, parallel, expanded capacity or 100% redundancy. Remote switching of Master / Slave possible. Cabeling on site, commissioning by Pneumatex Service. Master-slave Ms 2 Parallel operation of 2 Transfero TI. Including assembly kit with 1 safety valve for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels. MS 2 T Master-slave Ms 3 Parallel operation of 3 Transfero TI. Including assembly kit with 2 safety valves for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels. MS 3 T Master-slave Ms 4 Parallel operation of 4 Transfero TI. Including assembly kit with 3 safety valves for protection of the maximum pressure at Transfero TU, TU...E and TG, TG...E expansion vessels. MS 4 T

41 Pressure maintenence systems WiTh PumPs - TRANsfERo TI Additional equipment Liz/Paz: Additional equipment for systems >110 C according to EN 12952, EN Max. admissible ambient temperature, TU: 40 C Supply voltage: 230 V/50 z Paz: Max. admissible temperature, TS: 70 C Min. admissible temperature, TSmin: 0 C Min. admissible pressure, PSmin: 0 bar Enclosure class: IP 54 Liz IA K4 Water level controller. Mounting on the Transfero TGI... vessel. With signal lamps and 4 floating contacts to indicate content is minimal or maximal, water makeup start and water make-up stop. Complete in a casing for mounting on the TGI... vessel. TÜV-tested type approval label WP VN [l] T IA K4/ ,5 0, IA K4/ ,5 0, IA K4/ ,5 0, IA K4/ ,5 0, IA K4/ ,5 0, IA K4/ ,5 0, Paz PMIN Minimum pressure switch. For retrofitting to Transfero TI. Fitting on site into Tecox and connection to control module. TÜV-tested in accordance with VdTÜV ruck 100/1 for specialised equipment and according to PE/EP 97/23/EC. Ps T s Pp Paz PMIN 0-6 Paz PMIN 6-16 Paz PMIN 0-25 PMIN ,5 G1/ PMIN ,5 G1/ PMIN ,5 G1/ Paz PMIN TI Minimum pressure switch. Factory fitted to Transfero TI. Pre connected to control module. TÜV-tested in accordance with VdTÜV ruck 100/1 for specialised equipment and according to PE/EP 97/23/EC. Ps T s Pp Paz PMIN 0-6 Paz PMIN 6-16 Paz PMIN 0-25 PMIN 0-6 TI ,5 G1/ PMIN 6-16 TI ,5 G1/ PMIN 0-25 TI ,5 G1/ T = epth of the device Informations complémentaires system design: Online calculation software SelectP! short cuts and terms: atasheet Planning and calculation. Glossary. The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by TA ydronics without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit

Pressure maintenance systems with compressors

Pressure maintenance systems with compressors Pressure maintenance systems with compressors Compresso Pressure maintenance systems with compressors Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING AVANTAGE Compresso

More information

Pressure maintenance systems up to 10 MW with pumps

Pressure maintenance systems up to 10 MW with pumps Pressure maintenance system with pumps Transfero T_ Pressure maintenance systems up to 10 MW with pumps Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING ADVANTAGE Pneumatex

More information

Transfero TI. Pressure maintenence systems with pumps Pressure maintenance systems up to 40 MW with pumps

Transfero TI. Pressure maintenence systems with pumps Pressure maintenance systems up to 40 MW with pumps Transfero TI Pressure maintenence systems with pumps Pressure maintenance systems up to 40 MW with pumps IMI PNEUMATEX / Pressurisation / Transfero TI Transfero TI Transfero TI is a precision pressure

More information

Transfero T_. Pressure maintenance system with pumps For systems up to 10 MW

Transfero T_. Pressure maintenance system with pumps For systems up to 10 MW Transfero T_ Pressure maintenance system with pumps For systems up to 10 MW IMI PNEUMATEX / Pressurisation / Transfero T_ Transfero T_ Transfero T_ is a precision pressure maintenance device up to 10 MW

More information

Compresso Connect F. Pressure maintenance systems with compressors For heating systems up to 4 MW and cooling systems up to 6 MW

Compresso Connect F. Pressure maintenance systems with compressors For heating systems up to 4 MW and cooling systems up to 6 MW Compresso Connect F Pressure maintenance systems with compressors For heating systems up to 4 MW and cooling systems up to 6 MW IMI PNEUMATEX / Pressurisation / Compresso Connect F Compresso Connect F

More information

Transfero TVI Connect

Transfero TVI Connect Transfero TVI Connect Pressure maintenance system with pumps and integrated cyclonic vacuum degassing For heating systems up to 8 MW and cooling systems up to 13 MW IMI PNEUMATEX / Pressure Maintenance

More information

Aquapresso. Pressure stabilisation for potable water Pressure stabilisation for potable water

Aquapresso. Pressure stabilisation for potable water Pressure stabilisation for potable water Aquapresso Pressure stabilisation for potable water Pressure stabilisation for potable water IMI PNEUMATEX / Pressure Maintenance and Control / Aquapresso Aquapresso Expansion vessels with fixed gas cushion

More information

Compresso Connect. Pressure maintenance systems with compressors For heating systems up to 12 MW and cooling systems up to 18 MW

Compresso Connect. Pressure maintenance systems with compressors For heating systems up to 12 MW and cooling systems up to 18 MW Compresso Connect Pressure maintenance systems with compressors For heating systems up to 12 MW and cooling systems up to 18 MW IMI PNEUMATEX / Pressurisation / Compresso Connect Compresso Connect Compresso

More information

Accessories. Accessories for pressure maintenance

Accessories. Accessories for pressure maintenance Accessories Accessories for pressure aintenance IMI PNEUMATEX / Accessories and ervice / Accessories Accessories High quality accessories coplete the range of PNEUMATEX pressure aintenance products. Thus

More information

Vento VI Connect VI 19/25 INSTALL

Vento VI Connect VI 19/25 INSTALL en de fr nl SAFETY INSPECTION DISASSEMBLING prescriptions 2 SAFETY INSPECTION Personnel Installing and operating personnel must possess the appropriate knowledge and training. Follow the instructions Installation,

More information

Pressure maintenance system with pumps and integrated vacuum degassing

Pressure maintenance system with pumps and integrated vacuum degassing Transfero TV Connect Pressure maintenance system with pumps and integrated cyclonic vacuum degassing For heating systems up to 8 MW and cooling systems up to 13 MW IMI PNEUMATEX / Pressurisation / Transfero

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

Compresso Connect F INSTALL

Compresso Connect F INSTALL en de fr nl SAFETY INSPECTION DISASSEMBLING prescriptions SAFETY INSPECTION Personnel Installing and operating personnel must possess the appropriate knowledge and training. Follow the instructions Installation,

More information

TA-H.U.B. Centralised balancing and control ENGINEERING ADVANTAGE

TA-H.U.B. Centralised balancing and control ENGINEERING ADVANTAGE Prefab units TA-H.U.B. Centralised balancing and control Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE This customised balancing solution lets you balance

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

STAP. Differential pressure controller DN

STAP. Differential pressure controller DN STAP Differential pressure controller DN 65-100 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE The flanged STAP is a high-performing differential pressure

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Compresso Connect C10.1 / C15.1 / C10.2 / C15.2 INSTALL

Compresso Connect C10.1 / C15.1 / C10.2 / C15.2 INSTALL SAFETY INSPECTION DISASSEMBLING prescriptions en de fr nl SAFETY INSPECTION Personnel Installing and operating personnel must possess the appropriate knowledge and training. Follow the instructions Installation,

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment) Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium

More information

STAP. Differential pressure controller DN 15-50

STAP. Differential pressure controller DN 15-50 Differential pressure controller 15-50 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE is a high-performing differential pressure controller that keeps the

More information

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050

More information

LIKE ME. Expert, highly efficient and customer-orientated

LIKE ME. Expert, highly efficient and customer-orientated Pressure maintenance solutions that are LIKE YOU Simply Compresso Statico Compresso C10 F Connect Transfero TVI Connect LIKE ME. Expert, highly efficient and customer-orientated IMI Pneumatex: A company

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E AIRFIX EXPANSION VESSELS Flamco Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E Flamco Edition 2005 / EXP Flamco Flamco offers you a wide choice

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119 Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Micro-S / Micro-S Digital Wall Hung Unit Please fulfil all listed requirements prior to and during

More information

PNEUMATEX. Product overview as per International edition Products Applications Benefits PNEUMATEX

PNEUMATEX. Product overview as per International edition Products Applications Benefits PNEUMATEX NEUMATEX 360 roduct overview as per 03.2009 International edition roducts Applications Benefits NEUMATEX New roducts for 2009 Transfero pressure maintenance and Vento degassing for particularly high pressures

More information

STAD-C. Balancing valve ENGINEERING ADVANTAGE

STAD-C. Balancing valve ENGINEERING ADVANTAGE STA-C Balancing valve Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE The STA-C balancing valve has been specially developed for use in indirect cooling systems

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Flamco Flexcon M-P Pump automat

Flamco Flexcon M-P Pump automat Flexcon M-P Pump automat 0664 Flex MP-eps GB Installation and operating instructions 1999, Flamco 2 Installation and operating instructions Flexcon M-P pump automat Dear customer, GB With the purchase

More information

System Pressure Manager Standard & System Pressure Manager Plus

System Pressure Manager Standard & System Pressure Manager Plus System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

TBV-CM. Combined control & balancing valves for small terminal units For modulating control TBV-CM Combined control & balancing valves for small terminal units For modulating control IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the

More information

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk

More information

Pressurisation Systems. Variomat. Pump Controlled Pressurisation Systems. Pressure maintenance Deaeration Water make-up. For Control Touch:

Pressurisation Systems. Variomat. Pump Controlled Pressurisation Systems. Pressure maintenance Deaeration Water make-up. For Control Touch: Variomat Pump Controlled Pressurisation Systems Pressure maintenance Deaeration Water make-up For Control Touch: 17 Control Unit Control Basic Control Basic S Control Touch 2-line LCD display 8 control

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Models: DS 126 Single Pump / Single System DT 126 Twin Pump / Single System DS 160

More information

GENO -Flushing Compressor Product Data Sheet F 02

GENO -Flushing Compressor Product Data Sheet F 02 GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up

More information

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...

More information

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES P0170E-1.DOCX/08.16/MG CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES With a Central Gas Supply System, individual work places or gas take-off stations are supplied with gas through

More information

SonoSelect 10 and SonoSafe 10 energy meters

SonoSelect 10 and SonoSafe 10 energy meters SonoSelect 10 and SonoSafe 10 energy meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.: Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II

More information

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

TRV-2, TRV-2S. Thermostatic radiator valves With presetting

TRV-2, TRV-2S. Thermostatic radiator valves With presetting TRV-2, TRV-2S Thermostatic radiator valves With presetting IMI EIMEIER / Thermostatic heads and Radiator valves / TRV-2, TRV-2S TRV-2, TRV-2S Thermostatic radiator valve primary for radiators in heating

More information

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide GRUNDFOS alldos product information Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide Construction and function Modular system Vacuum regulator for direct mounting

More information

ELADOS EDP L Diaphragm Metering Pump Type

ELADOS EDP L Diaphragm Metering Pump Type ELADOS EDP L Diaphragm Metering Pump Type 04800-06700 Motor-driven diaphragm pump with integrated frequency converter High reserves due to a powerful asynchronous motor High flexibility due to variably

More information

Expansion Vessels for Potable Installations

Expansion Vessels for Potable Installations 4. Expansion Vessels for Potable Installations Domestic installations lose millions of litres of potable water due to expansion water leaking from the vent and expansion pipe. Flamco s Airfix diaphragm

More information

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Description AVP(-F) is a self-acting differential pressure controller primarily for use in district heating systems.

More information

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics TA-FUSION-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P TA-FUSION-P These innovative

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in

More information

Technical Manual. Liquid Level Transmitter CT801-LB/S

Technical Manual. Liquid Level Transmitter CT801-LB/S CT801-LB/S Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CT801-LB/S 1 st Edition Released

More information

Pressure Calibrators. Series PC..., PM...

Pressure Calibrators. Series PC..., PM... Pressure Calibrators Series PC..., PM... SIKA-Precision Pressure Calibrators, Series PC..., PM... We help you, if you are under pressure! Pneumatic pressure calibrators PM 25 A, PM 25 D, PM 110 PIC pressure

More information

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, INTRODUCTION Hydropneumatic tanks are designed to be used in potable water supply installations as a part of the pressure booster set in order to ensure the adequate

More information

STAD. Balancing valves DN 15-50

STAD. Balancing valves DN 15-50 STAD Balancing valves DN 15-50 IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for use on the

More information

Flamco Flamco-Fill STA Flamco-Fill STM

Flamco Flamco-Fill STA Flamco-Fill STM STA STM Typ STA 5936 Typ STM 5937 GB Installation and operating instructions 1999, 2 Contents GB UK Limited P.O. Box 9, Washway Lane, St. Helens, Merseyside WA10 6FE United Kingdom Telephone: 01744 744744

More information

MEDICAL EQUIPMENT CATALOG

MEDICAL EQUIPMENT CATALOG THE MOST TRUSTED MEDICAL EQUIPMENT IN NORTH AMERICA MEDICAL EQUIPMENT CATALOG Total Components Including Bulk Oxygen Supply, Back up and Delivery Equipment Designs for High Pressure, Liquid or Bulk Applications

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads TBV-CM Combined control & balancing valves for small terminal units For modulating control NPT threads IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling

More information

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air

More information

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions Ballorex Delta Description The Ballorex Delta is a differential pressure control valve used in hydronic heating or cooling systems. By ensuring a constant differential pressure across motorized or static

More information

Differential pressure gauge For the process industry Model , all-metal media chamber

Differential pressure gauge For the process industry Model , all-metal media chamber Pressure Differential pressure gauge For the process industry Model 732.51, all-metal media chamber WIKA data sheet PM 07.05 for further approvals see page 4 Applications For gaseous and liquid aggressive

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

STAD. Balancing valves DN (MD60, MD61, MD62)

STAD. Balancing valves DN (MD60, MD61, MD62) STAD Balancing valves DN 15-50 (MD60, MD61, MD62) IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited

More information

TA-FUSION-P. NPT threads / ANSI flanges

TA-FUSION-P. NPT threads / ANSI flanges TA-FUSION-P NPT threads / ANSI flanges Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P

More information

AVP-F. p setting range (bar) Code No. 003H6200

AVP-F. p setting range (bar) Code No. 003H6200 Data sheet Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Description The controller has a control valve, an actuator

More information

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h Thermal Mass Flowmeter for compressed air and gases measuring monitoring analysing KMT Measuring range: 0.32... 63 Nm³/h - 263.4... 263350 Nm³/h Accuracy: ± 1.5% of reading + 0.5% of full scale ( DN 50)

More information

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA CT801-SI, CT801-TA Maintenance Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Maintenance Manual CT801-SI, CT801-TA

More information

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options TB 42 TB 42 commercial vehicle wash for automatic exterior cleaning. The 3-brush gantry allows a washing height of 4.25 m and offers total flexibility for different vehicle sizes and types. 1 Low maintenance

More information

Digital Flow Switch. Series PFM7

Digital Flow Switch. Series PFM7 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22. *09005087* DB_BA_EN_ME01_S Rev.A 12/16 *09005087* d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual ME01 Digital manometer Table of Contents ME01 ## # 87 # HL S#### Dust explosion protection

More information

Types and approvals. Page 1/6. Data Sheet

Types and approvals. Page 1/6. Data Sheet Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation

More information

KTM 50 (DN ) Installation, maintenance and operating instructions

KTM 50 (DN ) Installation, maintenance and operating instructions 52 762-306 09.2014 KTM 50 (DN 100-200) Installation, maintenance and operating instructions General High-performing and compact, these pressure-independent control valves for variable flow heating and

More information

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements

More information

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids No contact with the product Compact design with polycarbonate housing (electronics and display).

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 143 N 143 SP.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

EPP4 Pressure Regulator Basic G 1/4"

EPP4 Pressure Regulator Basic G 1/4 EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard

More information

Visualize Nitrogen Gas Consumption

Visualize Nitrogen Gas Consumption Air Flow Monitor EWA2 SERIES Conforming to EMC Directive (all models) & Pressure Equipment Directive (AEWA2150/2200 only) Visualize Nitrogen Gas Consumption Small pipe size as Well as Air Consumption!

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information