Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7
|
|
- Rachel Greene
- 11 months ago
- Views:
Transcription
1 Models 461-S, 461-8S and S Regulators R-1330 Rev. 7
2 461-S, 461-8S and S Regulators The Sensus Models 461-S, 461-8S and S are balanced valve, spring type regulators designed for distribution and industrial applications where a single seat regulator is too small and the usual 2 balanced valve regulators are too large. They are made in 2 pipe sizes only and are used for: Inlet Pressures to 175 psi Outlet Pressures of 0 to 10 psi The 461-S and S are unusually dependable regulators. Their design is simple, the construction is sturdy. Servicing and adjustment are easy, response is fast. The overall operation is stable and sensitive, and they provide exceptionally precise regulation. The 461-S 461-8S and S are excellent regulators for general usage. They also make an excellent choice for such special applications as snap action on-off loads and monitoring service. Contoured body passages for reducing turbulence and large exit areas give them a broad capacity capability thus making them applicable to a wide variety of load handling requirements. Their outstanding control characteristics are illustrated by the curves on Page 4. Capacities are provided on Page 7. Maximum Inlet Pressure Diaphragm Size I.D. 12 Diaphragm Case Material Maximum Inlet Pressure* 100 psi psi 12 Aluminum 100 psi 8 Aluminum 175 psi *The regulator should not be used for pressures exceeding the recommended maximum inlet. Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft- Seated Valve Materials* Valve Material Buna-N (black, 50 to 55 duro) Polyurethane (red, 65 to 75 duro) Polyurethane (tan, 85 to 95 duro) Maximum Pressure Differential 250 psi 400 psi 600 psi Maximum Inlet Pressure 575 psig 720 psig 1200 psig *The differential and inlet pressures given are only to be used as general guidelines. In all cases, pressures must always remain within the ranges specified in Sensus literature. For any given regulator, do not exceed the specified maximum pressures. The maximum temperature for the above materials is 150ºF. Vitron valve material has a maximum temperature rating of 300ºF and a maximum pressure differential of 250 psi. Body Pressure Ratings Regulator Body Type Screwed End ANSI 125 lb. FF ANSI 250 lb. RF ANSI 300 lb. RF Maximum Working Pressure of Body* 250 psi 175 psi 575 psi 720 psi *This only applies to the body. The regulator should not be used for inlet pressures that exceed the maximums specified in the Maximum Inlet Pressure table above. 1
3 Spring Ranges Diaphragm Diaphragm Case *2 w.c. 4 w.c. 7 w.c. 0.5 psi 1 psi Outlet Pressure 10 w.c. 16 w.c. 29 w.c psi 3.5 psi Nominal Diaphragm Size (I.D.) and Case Material Maximum Inlet Pressure* Aluminum Green Yellow Gray Blue 3.5 w.c. 5 w.c. 6 w.c. 12 w.c. 1 psi 1.5 psi 6.5 w.c. 8.5 w.c 14 w.c. 28 w.c. 2 psi 3 psi 12 Aluminum 12 Aluminum 12 Aluminum 12 Aluminum 12 Aluminum 12 Aluminum Red Blue Green Orange Black Cadmium 3 psi 5 psi 6 psi 10 psi Blue Red 1 psi 2 psi 3 psi 6 psi 2 psi 4.25 psi 6.5 psi 10 psi 8 Aluminum 8 Aluminum 8 Aluminum 8 Aluminum For outlet pressures above 3 psi refer also to: Model S - a direct operated spring regulator for 100 psi maximum outlet (Bulletin R1331). Model a pilot operated regulator for 150 psi maximum outlet (Bulletin R1341). Orange Black Cadmium Cadmium (outer) White (inner) *For pressures below 2 w.c. install regulator in inverted position. Springs are colored for identification. When shipped, the regulator is equipped with the lightest possible spring suitable for the maximum outlet pressure specified on order. If outlet conditions change, replace spring according to table for best operation. Temperature Limits The 461-S, 461-8S and S regulators may be used for flowing gas temperatures from -20º to 150ºF. Buried Service The 461-S, 461-8S and S regulators are not recommended for buried service. 2
4 Construction and Design Features 461-S, 461-8S and S Gas Pressure Regulators SET POINT ADJUSTMENT Heavy Duty Diaphragm Case (shown) (Sizes and 12 I.D.) Lightweight Aluminum Diaphragm Case (Sizes 8 and 12 I.D.) VENT Optional Valve Travel Indicator INLET OUTLET Control Line Connection (Differs on Aluminum case 461-8S and S. See bulletin RM-1330.) Balanced Valve Full Size and Reduced Sizes (See pages 7 and 8), Ductile Iron or Cast Steel Body (See pages 10 and 11) Construction Features Regulator self contained-no exposed parts-top moisture sealed-safe for pits by extending vent line. Flow contoured body-large gas exit area reduces turbulence, increased capacity. Side inspection plates-o-ring sealed-for visual valve inspection or adjustment. Balanced valve-permits higher inlet pressures-eliminates variation effect-gives greater capacity. Soft seat valves-tight lock-up at zero flow. Molded discs resist blow out. Adjustable valve spacing. Renewable orifices-two interchangeable sizes. Springs color coded-self-aligning adjustment-easily changed through gasketed top opening. 3
5 Typical Performance Curves Performance These performance curves are typical for the Model 461-S. The outlet pressure for each chart was set under the stated conditions and was not further adjusted during changes in inlet pressure or flow. Settings in general were made at an inlet of 5 psi. From set point to lock-up at zero flow requires a pressure increase of not more than 3 w.c. 4
6 Model 461-S, 461-8S, and S Capacity Tables Capacity in 100 SCFH of Natural Gas (0.6 Specific Gravity psia-60ºf) The single seat balanced valve should not be used for outlet pressures below 1 psi. Size each regulator on the basis of the minimum expected inlet pressure and the maximum required outlet pressure. If greater capacity is required, refer to Model 441-S (Bulletin R-1350). Expanded Outlet Line These flow rates represent the amount of gas the regulator can actually pass at the given pressure reduction. This amount often exceeds the amount a 2 outlet line can take away, and the flow is restricted to the line capacity. To take advantage of the regulator s capacity, make certain the outlet line has equal capacity, and increase the line size at the regulator s outlet as necessary, to secure adequate capacity. Note: The above performance data is based on normal testing at 70º flowing temperature. Changes in performance can occur at extreme low flowing temperatures. 5
7 Relief Valves and Back Pressure Valves For those applications which require a higher degree of accuracy and sensitivity than is possible with standard poppet type reliefs, use the Model 461-SR. Essentially, its a regulator arranged to provide inlet pressure control. When operating as a relief valve, it limits inlet pressure to a set maximum. At pressures below this, it remains closed. If the pressure should attempt to exceed this, it opens and bleeds off the excess. The 461-SR is the same as the 461-S except that the inner valve is reversed, the body is turned around, and the control line is arranged for connection to the inlet sign (upstream). The Model 461-SR offers these advantages: (1) accurate setting and control at low relieving pressure because of large, sensitive diaphragm; (2) tight shutoff without leakage due to soft-seat valve construction; (3) large relieving capacity due to large size double valves. As a back pressure valve, it prevents gas from exiting from a system until the system pressure reaches the set point. At set point it begins to open and then regulates the discharge so as to hold the system at set point. Relief Pressure Range 3 w.c. to 10 psi (for range of each spring and diaphragm combination, see table, Page 3.) Installation 1. Install in line as shown with pressure connected to side marked INLET. 2. For gas, pipe outlet to safe discharge point. 3. Connect inlet line to 1/4 union. 4. By turning adjustment screw, set valve to open at desired pressure. Turning clockwise increases opening pressure. Overpressurization Protection Protect the downstream piping system and the regulator s low pressure chambers against overpressurization (due to possible regulator malfunction or failure) to achieve complete lockup. The allowable outlet pressure is the lowest of the maximum pressures permitted by federal codes, state codes, Sensus Bulletin RDS-1498, or other applicable standards. The method of protection can be a relief valve, monitor regulator, shutoff device, or similar mechanism. Maximum Emergency Pressures For complete Maximum Emergency Pressure information for Model 461 regulators, refer to Sensus Bulletin RDS-1498, Regulator Pressure Ratings. If the maximum outlet pressure is exceeded, the regulator must be removed from service and carefully inspected. Damaged or otherwise unsatisfactory parts must be replaced before returning the regulator to service. Periodic Inspection: Regulators are pressure control devices with numerous moving parts subject to wear that are dependent upon particular operating conditions. To assure continuous satisfactory operation, a periodic inspection schedule must be adhered to with the frequency of inspection determined by the severity of service and applicable laws and regulations. See Bulletin RM-1330 for field service instructions. 6
8 Materials of Construction Monitoring The 461-S, 461-8S, or S make an excellent monitor; a standby regulator installed in series which assumes control if a failure in the operating regulator permits the outlet pressure to exceed the set point. The fast rate of response enables it to take over quickly where necessary, and its outstanding performance means that it will provide excellent stnadby regulation. It can be located in either the upstream or the downstream position. When a 461 is used to monitor a regulator with an identical inner valve (another 461, a Model 1100, etc.) the total maximum capacity through both can be figured at 70% of the capacity of one of them alone. This applies with the monitor located either upstream or downstream. Capacities at Other Pressures Capacity for pressures not listed in the table on Page 6 can be calculated with the following formuale: Metrication 1. Q = K P o (P I - P o ) 2. Q = KP I 2 Q = maximum capacity of the regulator (in SCFH of 0.6 specific gravity natural gas.) K = the K factor, the regulator constant (from the table) P I = absolute inlet pressure (psia) P o = absolute outlet pressure (psia) P I P o P I P o Use formula 1. when is less than Use formula 2. when is greather than Other Gases 461-S, 461-8S and S regulators are mainly used on natural gas. However, they perform equally well on LP gas, nitrogen, dry CO 2, air and others. For use with gases not listed, please contact your Sensus representative or industrial distributor for recommendations. How to Order 1. 2 Model 461-S, S or 461-8S. 2. Body Type (see table, on Page 10). 3. Outlet Pressure and Spring (see table, Page 2). 4. Inlet Pressure (also, minimum and maximum inlet pressures, if available). 5. Capacity required (SCFH). 6. Type of Gas (natural gas, propane, etc.). 7. Trim (brass or stainless steel). 8. Valve size (1 or ). 9. Double seat or single seat (see Pages 8 and 9)-if not specified, double seat will be furnished. 7 OTHER GASES To Order Parts, Specify: CORRECTION FACTOR Air (Specific Gravity 1.0) 0.77 Propane (Specific Gravity 1.53) BTU Propane-Air Mix (1.20) 0.71 Nitrogen (Specific Gravity 0.97) 0.79 Dry Carbon Dioxide (Specific Gravity 1.52) 0.63 For other noncorrosive gases: CORRECTION FACTOR= 0.6 Specific Gravity of the Gas 1. Pipe size and model number of regulator. 2. Serial number of regulator (if available) or other identifying information. 3. Part number and name of part. 4. Quantity. 5. For orifices and valve parts-specify size of valve (1 or ) and trim (brass or stainless steel). 6. For diaphragm, diaphragm plates, or upper or lower coversspecify material and size (12 Al., 8 Al., 12 CI or CI). 7. For springs-specify color and part number. Part numbers and names can be found in Bulletin RM-1330.
9 Model 461 Balanced Valves Fully Interchangeable Valve Assemblies Valve assemblies can be interchanged with the regulator in place in the line. 461-S with Double Seat Balanced Valve Molded Soft Seats For positive tight shut-off 461-S with Single Seat Balanced Valve Double Seat Balanced Valve 1 or Valve is available with V-Port retainers which provide greater turndown performance Single Seat Balanced Valve 1 or Lock-up Adjustment clamp-thread type Easy to adjust-accurate same orifice Balancing Piston (O-ring seal) No Lock-up Adjustment Caution: Turn gas on slowly. If an outlet stop valve is used, it should be opened first. Do not over load the diaphragm with a sudden surge of inlet pressure. Monitor the outlet pressure during start-up to prevent an outlet pressure overload. Refer to RM-1330 for more detailed start-up procedures. 8
10 The 461 Family of Regulators Other 461 Models for Distribution Systems and Industrials 2 Model S Roll-Out Diaphragm Regulator Outlets of 3 to 100 psi See Bulletin R Model 1100 Pilot Operated Regulator See Bulletin R Model 461-X57 High-Pressure Roll-Out Diaphragm Regulator Outlets of 75 to 250 psi See Bulletin R Model 1200 All steel construction Outlets to 600 psi See Bulletin R-1342 Caution: It is the user s responsibility to assure that all regulator vents and/or vent lines exhaust to a nonhazardous location away from any potential sources of ignition. Refer to Sensus Bulletin RM-1330 for more detailed information. 9
11 Dimensions Model 461-S Regulator Body Type A B C D (12 ) D (8 1 2 ) Shipping Weight Lbs. Body Material Screwed End (ASTM A class B) 125 lbs (ASTM A class B) 250 lbs. 300 lbs Ductile Iron (ASTM A gr ) Cast Steel (ASTM A216-70a gr WCB) Model 461-8S Model S Regulator Body Type A B C D (12 ) Shipping Weight Lbs. Body Material Regulator Body Type A B C D (12 ) Shipping Weight Lbs. Shipping Body Material Screwed End (ASTM A class B) Screwed End (ASTM A class B) 125 lbs (ASTM A class B) 125 lbs (ASTM A class B) 250 lbs. 300 lbs Ductile Iron (ASTM A gr ) Cast Steel (ASTM A216-70a gr WCB) 250 lbs. 300 lbs Ductile Iron (ASTM A gr ) Cast Steel (ASTM A216-70a gr WCB) 10
12 Sensus Metering Systems, 805 Liberty Boulevard DuBois, PA (814) FAX (814) Representatives in all principal cities. Distributors throughout the world. Sensus Metering Systems 805 Liberty Boulevard DuBois, PA Authorized Distributor: NUPP 5/07 3M PRINTED IN U.S.A.
R-1450 R6. Safety Relief Valve
R-1450 R6 Safety Relief Valve T H E G A S I N D U S T R Y Purpose Safe practice in the transmission, distribution and utilization of gas requires a device to limit line pressure to a predetermined safe
Pressure and Temperature Controls
Pressure and Temperature s Pressure Reducing s pressure reducing valves (PRVs) and temperature regulators help you manage steam, air and liquid systems safely and efficiently. And assure uninterrupted
CL38 Regulator Commercial & Industrial Regulator
Gas CL38 Regulator Commercial & Industrial Regulator Applications Appropriate for commercial and industrial applications where very accurate pressure control is required such as fixed-factor metering applications
Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators
Product Line Brochure J0B Effective Date 2/01 Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators P R O D U C T L I N E O V E R V I E W Regulator
CL31 Series Regulator Commercial Regulator
CL31 Series Regulator Commercial Regulator The CL31 regulator can produce substantial savings for users in lower initial costs, lower installation costs and lower maintenance costs. Optimum valve design
Types S100K and S102K Pressure Regulators
Instruction Manual Form 5624 Types S0K and S2K 01/01 Types S0K and S2K Pressure Regulators W7478-1 Figure 1. Types S0K and S2K Pressure Regulator Introduction Scope of Manual This manual provides instructions
Installation, Operation and Maintenance Manual for Back Pressure Regulator
Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN
INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION
INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic
B31 Series Regulator Light Commercial and Industrial Regulator
B31 Series Regulator Light Commercial and Industrial Regulator Appropriate for light commercial and industrial uses where inches of water column or pounds delivery is desired such as utility services and
Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000
Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They
Precision and Instrument Regulators 1/4" port size
Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38
Gas Pressure Regulator HON 270 MK2
Gas Pressure Regulator HON 270 MK2 PRODUCT INFORMATION Serving the Gas Industry Worldwide Introduction, Application, Features & Technical Data Introduction The HON 270 MK2 regulator is a direct acting,
POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS
POP Safety Valve POP Safety Valve INTRODUCTION The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant and personnel. Safety
Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.
Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing
Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators
Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators January 2016 Differential as low as 1 psi / 70 mbar Materials of Construction Compatible with Below Grade Installations Quick Change Trim Package
RTG 25. Introduction
Introduction RTG 25 pressure regulator is included within the direct acting and balanced valve regulator class. These regulators have a large range of applications both in industrial and domestic installations.
Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications
Instruction Manual Form 5753 Type HSR October 2003 Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications W8648 Figure 1. Type HSR Pressure Regulator Introduction
Model GP PRESSURE REDUCING VALVE Installation & Operation Manual
Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully
Dival 600. Pressure Regulators
Dival 600 Pressure Regulators Pressure regulators Dival 600 Dival 600 series pressure regulators are direct acting devices for low and medium pressure applications controlled by a diaphragm and counter
Anti-flood device Model B-1
December 4, 2009 Dry Systems 123a 1. DESCRIPTION The Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET
TECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
TECHNICAL DATA. Q = C v P S
Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction
Pressure Regulators. Aperflux 851
Pressure Regulators Aperflux 851 80 1 2 3 4 5 6 7 Aperflux 851 > Pressure regulators Introduction Aperflux 851 is a boot style pilot-controlled pressure regulator for medium and high pressure applications.
GAS SUPPLY DESIGN GUIDE
GAS SUPPLY DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing Boilers BENCHMARK Series Gas-Fired Boilers For models: BMK750 to BMK6000 Last Update: 06/20/2014 PR1 06/20/14
GAS SUPPLY APPLICATION GUIDE
GAS SUPPLY APPLICATION GUIDE Natural Gas or Propane Modulating & Condensing Boilers and Water Heaters This document applies to the following models: Boilers AM 399B AM 500B AM 750B AM 1000B Gas-Fired Boilers
PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT
PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT Model Number Model Description Page # Pilot operated Relief Valves Pilot Operated Relief Valves 3-27 Operation
TECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
Full Range Pressure Compensating Variable Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25
TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:
February 11, 2005 Deluge Valves 218 a 1. PRODUCT NAME Viking Model F-1 Deluge Valve 8" - Manufactured since 2002 4" & 6" - Manufactured since 2003 2-1/2" & 3" - Manufactured since 2004 2. MANUFACTURER
Pressure regulators. Introduction. TR Head. 3 ways body Dival
Pressure Regulators > Pressure regulators Introduction series pressure regulators are direct acting devices for low and medium pressure applications controlled by a diaphragm and counter spring. These
V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings
Installation Instructions V46 Issue Date 11//1 V46 Series -Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V46 Series -Way Pressure-Actuated Water-Regulating
XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION
DUAL FUEL EXCESS AIR BURNER MODEL: 3610, 3651 Revision: 0 FEATURES Burns all fuel gases or light oils Nozzle mix design for on ratio control or excess air 350% excess air all sizes on gas or oil Turndown
RB 4700 Commercial & Industrial Regulator
RB 4700 Commercial & Industrial Regulator The RB 4700 regulator is designed for use in industrial and distribution applications such as district station and heating plants, and for industrial customers.
Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs
Un-Pressurized Orefice Fittings FIO EZ Parts List and Operation Instructions TECHNICAL MANUAL Dn 2-6 Class 150-600 Lbs US US 2 FIO EZ - MT 108-US - 05-2016 FIO EZ Important Instructions US Pietro Fiorentini
G92 Series BASOTROL Automatic Pilot Gas Valve
Installation Instructions Issue Date September 17, 2008 G92 Series BASOTROL Automatic Pilot Gas Valve Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These
Operation Manual Piston Sensed Gas Pressure Regulators
687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:
BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features
Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level
Wet pipe low flow foam/water system
December 6, 2010 Foam 14a 1. The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with Viking supplied foam concentrates. This system consists of a standard
BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.
BULLETIN 20-7000 ROTAMETERS PURGE FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES. INTRODUCTION McCrometer purge rotameters are precision-made instruments designed to accurately
Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions
Before installation these instructions must be fully read and understood Installation and maintenance instructions for Series 93 Positive Pressure Pilot Operated Safety Relief Valves (POSRV). The intent
Choosing the right miniature instrument and control valve is a snap
Choosing the right miniature instrument and control valve is a snap INVALCO Micro Valve The Micro Valve is a unique miniature valve offering versatility and rugged construction. Since its introduction
Pressure Regulators Pressure regulation to maximize steam system efficiency
Pressure Regulators Pressure regulation to maximize steam system efficiency The density of steam increases as the pressure rises. Because of this characteristic, more pounds of steam can be stored in a
Testing Procedures & Trouble Shooting Guide Reduced Pressure Zone Assembly (1/2, 3/4", 1, 1 1/4, 1 1/2" & 2 )
Testing Procedures & Trouble Shooting Guide Reduced Pressure Zone Assembly (1/2, 3/4", 1, 1 1/4, 1 1/2" & 2 ) First Check Valve Test 1) Bleed all test cocks. First open test cock 4, make sure it is slightly
RELIABLE PROTECTION FOR A WIDE RANGE OF RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS. water pressure reducing valves
RELIABLE PROTECTION FOR A WIDE RANGE OF RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS water pressure reducing valves Table of Contents Product...Page How Pressure Reducing Valves Work...3 36 Series...
Commercial and Industrial Aluminumcase Diaphragm Meters Capacity Ratings from 800 scfh to 5000 scfh
SB 3510.3 Commercial and Industrial Aluminumcase Diaphragm Meters Capacity Ratings from 800 scfh to 5000 scfh AMC Quality System QMI is Accredited by: ISO 9002 Certified Dutch Council for Accreditation
ACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0501 FOR USE WITH 95% MODELS: TG9S, GG9S (130,000 BTU ONLY) FOR USE WITH 80% MODELS: TG(8,L)S, GG(8,L)S (130,000
GM-7000 Series CE Approved Gas Control Valve
Installation Instructions GM-7000 Issue Date November 9, 2012 GM-7000 Series CE Approved Gas Control Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing
Types S100C and S102C Pressure
Instruction Manual Form 5404 Types S100C and S102C Types S100C and S102C Pressure Regulators Introduction Scope of Manual This manual provides instructions for the installation, adjustment, maintenance
Float Operated Level Controllers
CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions
D05T Compact Design Pressure Regulating Valves
D05T Compact Design Pressure Regulating Valves FEATURES PRODUCT DATA Non-corroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass.
Type 1367 High-Pressure Instrument Supply System with Overpressure Protection
Instruction Manual D100343X012 Type 1367 November 2017 Type 1367 High-Pressure Instrument Supply System with Overpressure Protection TYPE 252 FILTER 2ND-STAGE TYPE 67CF FILTER-STYLE REGULATOR INLET TYPE
Pressure Regulators. Aperflux 101
Pressure Regulators Aperflux 101 Aperflux 101 > Pressure regulators Top Easy Maintenance Integral Silencing Cage High Accuracy Dinamically Balanced Pilot Installation On Any Position Introduction Aperflux
TECHNICAL DATA ACCELERATOR MODEL E-1
Page 1 of 10 1. PRODUCT DESCRIPTION The Viking Model E-1 Accelerator is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating
CATALOG. 2 nd Edition
CATALOG 2 nd Edition Service and installation must be performed by a trained/experienced service technician. All products used with combustible gas must be installed and used strictly in accordance with
Horizontal Bladder Tanks
DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
Vertical Bladder Tanks
DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
REGULATORS FOR SPECIFIC APPLICATIONS
SINGLE-STAGE REGULATORS FOR NITROUS OXIDE AND CARBON DIOXIDE (MODELS SG9011, SG9012, SG9014) Nitrous Oxide and Carbon Dioxide frequently cause ordinary regulators to freeze up. Models SG9011, SG9012 and
61 Series Pilots for Pilot-Operated Pressure Reducing Regulators
Instruction Manual Form 583 Series June 20 Series Pilots for Pilot-Operated Pressure Reducing Regulators Failure to follow these instructions or to properly install and maintain this equipment could result
300 Series. Automatic Hydraulic Control Valves
Automatic Hydraulic Control Valves AVFI Pty Ltd 54 Enterprise Drive Bundoora Vic 3083 p: 03 8467 0000 f: 03 8467 0099 e: avfi@avfi.com.au w: www.avfi.com.au 300 Series General 300 SERIES Automatic Hydraulic
Homestead Series 820 AWWA Butterfly Valves
Homestead Series 820 AWWA Butterfly Valves Dependable Valves for Water & Wastewater Service BODY: The ductile iron body meets or exceeds the design strength requirements of the AWWA C504 standards. Flange
BLANKET GAS REGULATORS
000 SERIES BLANKET GAS REGULATORS Model Numbers: // P // 020A 01L // P A Blanket Gas Regular supplies an inert gas prevent a vacuum from developing when liquid is removed from a tank, maintain the desired
PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.
PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
safety Shut-Off Valve HON 721
safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety
INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)
P/N 126905-01 Rev. B 11/2016 INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) For All Single, Dual and Triple Burner Natural and Propane/LP Gas Logs P126905-01 For
PRESSURE REDUCING VALVE EUROBRASS 143 FF
Scheda prodotto Eurobrass 143 ENG Rev. 5 09/2012 PRESSURE REDUCING VALVE EUROBRASS 143 FF Direct acting brass pressure reducing valve; PN 25; Adjustable outlet pressure between 0,5 and 6 bar; Brass diaphragm
Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications
Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range
Gas Pressure. Regulators Catalog. For Industrial Engines and Generator Sets. 2011, Maxitrol Company. All Rights Reserved.
Gas Pressure Regulators Catalog For Industrial Engines and Generator Sets 1 GAS PRESSURE REGULATORS For Industrial Engines and Generator Sets Service and or installation must be performed by a trained,
GIRARD EQUIPMENT, INC. Specialty Valve Manufacturers for Tank Trailers since 1952
Pressure Testing Girard DOT407 Pressure Relief Vents GIRARD EQUIPMENT, INC. Specialty Valve Manufacturers for Tank Trailers since 1952 908-862-6300 Toll Free 800-526-4330 FAX 908-862-8178 Website: www.girardequip.com
Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable
GEP-6075 Rev. B 101574 Ref. I.D.: 16973 Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE
829S1 Series Flexflo Pilot
REDQ Regulators The Model 829S1 Provides Versatile Pressure Regulation At An Economical Price. The Model 829S1 Flexflo Pilot is a reversible pressure control regulator (seat & nozzle) that is used in conjunction
INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300
INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300 MODEL VSP100 VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 FORM 30780
Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"
Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with
Type ACE97 Pad-Depad Valve
Instruction Manual Form 5665 Type ACE97 November 2011 Type ACE97 Pad-Depad Valve DEPAD PILOT VALVE DEPAD MAIN VALVE W8161 ACTUATOR VENT GAS INLET PAD VALVE TO TANK Figure 1. Type ACE97 Pad-Depad Valve
COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL
COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL SPECIFICATIONS: The CARD series air valves are available in 3 pipe sizes, 1, 2 and 4 NPT or socket. Maximum inlet pressure
Installation Instructions
LP and High Altitude LP Gas Conversion Kit For United States Installations Installation Instructions For Model Series *G6/PGF1 Furnaces, *L1/PGC1 Furnaces, and *R4/PPG1 Gas/Electric Appliances using Honeywell
V146 Series 2-Way Pressure-Actuated Water-Regulating Valves
roduct/technical Bulletin V146 Issue Date November 20, 2002 V146 Series 2-Way ressure-actuated Water-Regulating s The V146 Series 2-Way ressure-actuated Water-Regulating s regulate water flow and control
RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005
RDK-408D2 Cold Head Technical Manual SHI-APD Cryogenics Inc. 1833 Vultee Street Allentown, PA 18103-4783 U.S.A. Revision A: September 2005 (Reference SHI Manual: December 18, 2003 266404A CD32ZZ-160A)
Gas Pressure Regulator HON 300
Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction
Pressure & Flame Protection
Pressure & Flame Protection Safety & Regulating Valves Safety & Regulating Valves Pressure Reducing Valves - These valves are installed where there is a requirement to reduce the pressure from one level
High Precision Gauge Pressure Indicators
Series 1500 8½" Dial High Precision Gauge Pressure Indicators Series 1500 Gauges have capsule-type pressure elements up to and including the 150-psig range. Ranges of 200 psig and above have Bourdon tubes.
630 Series Regulators and Relief Valves
Instruction Manual Form 124 60 Series December 2015 60 Series Regulators and Relief Valves Introduction Scope of Manual This Instruction Manual provides operating, installation, maintenance and parts information
GILMONT ACCUCAL FLOWMETERS
OPERATING MANUAL GILMONT ACCUCAL FLOWMETERS 28W092 Commercial Ave. Barrington, IL U.S.A. 60010-2392 (847) 381-4888 (847) 381-7053 (Fax) 800-962-7142 www.barnant.com e-mail: barnant@barnant.com A-1299-0766
Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series
Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Main features Designed for automatic filling of sealed heating systems and for protection of the water mains from risk of contamination.
Safety Relief Valve HON 835
Safety Relief Valve HON 835 product information serving the gas industry worldwide safety relief valve HON 835 Application, advantages, technical data Application: as leakage relief valve (SBV) in gas
SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series
SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified
Volume Booster. Volume Booster Description Supply pressure Pressure range Connection Device Page max. bar bar thread
Volume ooster Supply pressure Pressure range onnection Device Page max. bar bar thread precise differential pressure also 17 0 1 / 10 and G 3 8 R50.02 differential pressure also 10 0.2 1 / 8 ¼ NPT 53.19
Safety Shut-Off Valve HON 720
Safety Shut-Off Valve HON 70 Product information serving the gas industry worldwide Application, Characteristics, Technical Data Application main safety device for gas pressure regulating stations suitable
DS05C,D,G Dial Set Pressure Regulating Valves
DS05C,D,G Dial Set Pressure Regulating Valves APPLICATION The Honeywell DS05C,D,G Dial Set Pressure Regulating Valve is a high quality pressure regulating valve that maintains a constant outlet pressure
TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
BGA158, BGA171 and BGA110 Series Shutoff Gas Valve
Installation Instructions BGA Series Issue Date October 3, 2017 BGA158, BGA171 and BGA110 Series Shutoff Gas Valve Applications The BGA Series shutoff gas valve is an electrically operated gas valve that
BGA158 Series CE Approved Class A Shutoff Gas Valve
Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that
TEST SPECIFICATION NYT-909-C
748 Starbuck Ave, Watertown, NY 13601 Phone: +1-315-786-5200 Engineering Fax: +1-315-786-5673 TEST SPECIFICATION NYT-909-C CODE OF TESTS FOR TESTING "AB" TEST RACK P/N 702546 & 702612 ISSUE NO. 5 1.0 THE
Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65
Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode
Pressure/Vacuum Diaphragm Valve PROTEGO UB/SF. deflagration- and endurance burning-proof
deflagration- and endurance burning-proof PROTEGO UB/SF 7 Ø b 4 The set pressure is adjusted with a freeze resistant water-glycol mixture, which assures safe operation under extreme cold weather conditions.
Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company
CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN
Anderson Greenwood Series 90/9000 Pilot Operated Pressure Relief Valves
Maximize operating pressure and minimize emissions with the Series 90/9000 pilot operated relief valve; a high performance alternative to weight loaded relief devices Features General application A wide
Standard Series Safety Relief Valves
Assistance: Our experienced and fully trained team of Technical Sales Engineers and distributors are available to give advice and assistance on the sizing and selection of the Bailey Standard Series and