Levitronix LEVIBOOST 75 or 140. up to 75 or 140 l/min up to 20 or 37 gpm MANUAL

Size: px
Start display at page:

Download "Levitronix LEVIBOOST 75 or 140. up to 75 or 140 l/min up to 20 or 37 gpm MANUAL"

Transcription

1 Levitronix LEVIBOOST 75 or 140 up to 75 or 140 l/min up to 20 or 37 gpm MANUAL This document contains information necessary for the safe and proper use of the LEVIBOOST 75 or 140 PL , Rev04, DCO# First Release: 11-Dec-09 Last Update: 27-Sep-17

2 Table of Contents 1 SAFETY PRECAUTIONS SPECIFICATIONS System Overview and General Specification System Features INSTALLATION Positioning the Tool Start setting of hydraulic load and pneumatic cooling Electrical Connections OPERATION System operating conditions Priming the Hydraulic Loop Emptying System to Drain Leak Sensor Impeller Replacement TROUBLESHOOTING Malfunction and Leakage Components TECHNICAL SUPPORT SYMBOLS AND SIGNAL WORDS PL , Rev05, DCO#

3 1 Safety Precautions CAUTION High magnetic field strength of pump impeller. The pump system contains a rotor magnet with high field strength. This may alter or damage the calibration of sensitive electronic devices and measuring instruments in the immediate surroundings. Keep at a safe distance from computers, monitors and all magnetic data storage media (e.g. disks, credit cards, audio and video tapes etc.)! WARNING Hazardous voltage may be present. The system is supply with electrical mains. The supply has to be protected with a leakage-current circuit breaker Do not under any circumstances open the powered system.! WARNING High magnetic field strength of pump impeller. The Bearingless Pump System BPS-600 or BPS-4 contains a rotor magnet with high field strength. Pace maker may be influenced and magnetic forces may lead to contusions. Keep distance to pace makers and handle impeller with care.! WARNING TOXIC CHEMICALS may be present. When using the system to pump chemicals skin contact and toxic gases may be hazardous to your health. Wear safety gloves and other appropriate safety equipment. PL , Rev05, DCO#

4 2 Specifications 2.1 System Overview and General Specification Figure 1: System Overview Figure 2: System Flow plan PL , Rev05, DCO#

5 Pos. Component Supplier Article # Article name Value / Feature 1 BPS-600 Levitronix Motor LPM (48V,ETFE,0.5m FEP, AMP Connectors) or Air Cooling Module ACM Pressure Sensor Surpass Industry Pump Head LPP or Pump Head LPP Flaretek 1 or Pillar Super Controller Set LPC (Includes Power Cabel PSC-3.1) Lambda RWS600B-48 Power supply 600W - 48V Material / Connection Port PP (+ 40% Talkum) / NPT ¼ Air Pressure / Consumption CS-P-15U-N or CS-P-15U-P300P (PTFE Housing, PFA-Impeller, Kalrez O-Ring) ~1-3 bar (14 43 psi) / bar (14.5 psi) Flaretek ½ or Pillar 300P ½ 4 Housing Levitronix LeviBoost Casing PVC-C (Drawing RM ) 5 Leakage sensor Flowline L PFA Housing (0~500kPa, DC24V+/- 10%, PFA, PTFE (all wetted parts) Table 1: Specification of main components LEVIBOOST 75 Flaretek (Art. #: ) and LEVIBOOST 75 Pillar (Art. #: ) Pos. Component Supplier Article # Article name Value / Feature 1 BPS-4 Levitronix Motor BSM (325V,ETFE,0.5m FEP, Circular Connectors) or Air Cooling Module ACM Pressure Sensor Surpass Industry Pump Head CP-4.26 or Pump Head CP-4.27 Flaretek 1 or Pillar Super (PTFE Housing, PFA-Impeller, Kalrez O-Ring) Controller Set LC325P-03 (Includes Mains Connector PSC-4.1) Material / Connection Port PP (+ 40% Talkum) / NPT ¼ Air Pressure / Consumption CS-P-15U-N or CS-P-15U-P300P ~1-3 bar (14 43 psi) / bar (14.5 psi) Flaretek ½ or Pillar 300P ½ 4 Housing Levitronix LeviBoost Casing PVC-C (Drawing RM ) 5 Leakage sensor Flowline L PFA Housing (0~500kPa, DC24V+/- 10%, PFA, PTFE (all wetted parts) Table 2: Specification of main components LEVIBOOST 140 Flaretek (Art. #: ) and LEVIBOOST 140 Pillar (Art. #: )! WARNING Risk of damage to the system with chemicals. Check the chemical resistance of system materials according to Table 1 or Table 2 against liquid. 2.2 Function of leakage detection The leak sensor is mounted on the base of the hydraulic part and is connected on the electrical side as NC switch (no leakage signal is active, leakage detected signal is not active) If any leakage is detected following actions will done immediate: - Pump turn off and change to the error mode - Red LED turn on - Message Leakage detected on the LUI display is visible PL , Rev05, DCO#

6 2.3 Maximal allowed system pressure General 5.0 bar / C / 77 F liquid temp. With Flaretek Fittings 2.7 bar / C / 194 F liquid temp. With Pillar Fittings 5.0 bar / C / 194 F liquid temp. 2.4 System Features Absolute accurate and constant liquid pressure Independent from variations in liquid supply Independent from variations in liquid consumption No particle generation based on the revolutionary magnetic levitation pump, contact-free operation Minimal foot print required - ultra compact design allows sub-floor installation Flexible performance ~1 l/min to 140 l/min Very economical - no water system infrastructure modifications required Low cost of ownership 2.5 General Environmental Conditions Usage Altitude Operating ambient temperature Operating humidity range (relative humidity) Storage humidity range (relative humidity) Mains supply fluctuations Transient over-voltages typically present on the mains supply Indoor Up to 2000 m 10 to 40 0 C 15 95% (non condensing) 15 95% (non condensing) 10% of nominal voltage Surge immunity according to EN Table 3: Environmental conditions for LeviBoost 2.6 Supply Information & Requirements Electrical power LeviBoost 75 LeviBoost VAC ± 10 % / A VAC ± 10 % / A 50 / 60 Hz 50 / 60 Hz Single phase Single phase Leakage-current protected Leakage-current protected Cooling Connection: ¼ Tube fitting Max. pressure: 6 bar Cooling Medium: Compressed air or N2 Table 4: Supply Information PL , Rev05, DCO#

7 Basic Dimensions LeviBoost 75 Figure 3: LeviBoost 75 Flaretek (in mm and [inch]) Figure 6: LeviBoost 75 Pillar (in mm and [inch]) PL , Rev05, DCO#

8 Basic Dimensions LeviBoost 140 Figure 9: LeviBoost 140 Flaretek (in mm and [inch]) Figure 12: LeviBoost 140 Pillar (in mm and [inch]) PL , Rev05, DCO#

9 3 Installation 3.1 Positioning the Tool Installation Step Positioning the tool Description 1. Move the tool to the specified position Table 5: Positioning the tool! WARNING! WARNING Heavy weight may squeeze feet. Use protective footwear Risk of FIRE Should not be installed next to flammable gases PL , Rev05, DCO#

10 3.2 Start setting of hydraulic load and pneumatic cooling Before some other operations connect the hydraulic and pneumatic lines to the specified connections:! WARNING! WARNING Risk of damage to the system with chemicals. Check the chemical resistance of system materials according to Table 1 or Table 2 against liquid. HARMFUL CHEMICALS may be present. Skin contact and toxic gases may be hazardous to your health. Wear safety gloves and other appropriate safety equipment. Installation Step Description Start setting of hydraulic load pneumatic cooling 1. Connect the facility inlet port 1 (Flaretek or Pillar male) Connect process outlet port 1 (Flaretek or Pillar male) PL , Rev05, DCO#

11 3. Connect facility drain port 3/8 (FNPT thread) Optional: connect pneumatic cooling line ¼ (PFA tube). Table 6: Start Setting of Hydraulic Load and pneumatic cooling PL , Rev05, DCO#

12 3.3 Electrical Connections! WARNING! WARNING Leakage current may be present. The LeviBoost must be protected with a leakage-current circuit breaker. Electrical installation only by qualified staff. Hazardous voltage may be present. Always isolate the electrical power supply before opening the casing. Installation Step Description 1 Remove side wall 1. To connect the electrical wiring open the side wall by removing the screws (8 pcs.). There are two bulkhead fittings (1.1) located on the side wall. Feed through the power cables for main connection (2.) and external control and system monitoring (3-6). 1.1 PL , Rev05, DCO#

13 PE 2. Connect the power cables with the main power switch. Tightening torque: 1 Nm X Leviboost 75 Electrical Power Signs 1 x VAC ± 10 % (single phase, 2-wire + protective earth): (1) = Neutral (3) = Line (PE) = Protective earth Leviboost Signs 1 x VAC ± 10 % (single phase, 2-wire + protective earth): (1) = Neutral / Line* (3) = Line / Line* (PE) = Protective earth *For connection to a 120/240 VAC split-phase or a 120/208 VAC three-phase electric power distribution. The voltage between (1) and (2) must be within 200 and 240 VAC (± 10 %) in any case. PE L N PL , Rev05, DCO#

14 EMO observation 3. EMO not active EMO active (1) (2) (1) (2) External EMO 4. Connect a switch for external EMO Signs: (3) = - pole (GND) (4) = +pole (24V) Switch closed ((4) & (5) connected) mains supply active Switch open ((4) & (5) disconnected) mains supply disconnected 5. No leakage detected Leakage detected Leakage Signal (5) (6) (5) (6) - Galvanic insulation with relay (insulation between coil and contacts, dielectric strength 4 kvac, rated impulse voltage (1.2/50 µs) 6 kv) - Breaking capacity DC1: 6 A / 30 VDC, 0.2 A / 110 VDC, 0.12 A / 220 VDC - Rated load AC1: 1500 VA / 250 V, AC15: 300 VA / 230 V 6. No Pump Error active Pump Error active Error Signal (7) (8) (7) (8) - Galvanic insulation with relay (insulation between coil and contacts, dielectric strength 4 kvac, rated impulse voltage (1.2/50 µs) 6 kv) - Breaking capacity DC1: 6 A / 30 VDC, 0.2 A / 110 VDC, 0.12 A / 220 VDC - Rated load AC1: 1500 VA / 250 V, AC15: 300 VA / 230 V PL , Rev05, DCO#

15 7. Pump enable is activated if appropriate Voltage is applied between (9) & (10): Voltage is applied Pump turns on (with last settings) Voltage is removed Pump turns off Pump enable - Galvanic insulation with relay (insulation between coil and contacts, dielectric strength 4 kvac, rated impulse voltage (1.2/50 µs) 6 kv) - Lowest input voltage for high level detection: 16.8 VDC - Typical 24 VDC / 7.2 ma, max. 30 VDC / 9.0 ma - Must drop-out voltage: 1.2 VDC - Input resistance (coil resistance): 3.35 kω PL , Rev05, DCO#

16 7 External EMO disabled 8. If the LEVIBOOST system is to be operated as a standalone module with only the internal EMO loop being utilized, the switch on the Relay as shown in the attached photo should be in the vertical position. 8 External EMO enabled 9. If the LEVIBOOST system is to be operated with an external EMO circuit (customer tool, etc.), the switch on the Relay as shown in the attached photo should be in the horizontal position. PL , Rev05, DCO#

17 9 Service port 10. RS232 Port for connection to external computer for access to Levitronix Service Software for service or maintenance. To activate the service port, switch the tumbler to the ON position. The blue light will be activated when the service port connection is established Standalone operation 11. For Standalone operation, switch the tumbler to the OFF position and the blue light will turn off to signify the service port communication has been disabled. The desired pressure setpoint can be set using the integrated user interface (see section 4.1 for instructions). Once configured with a set point, the system will be ready to use in a standalone operation mode. Units for pressure (bar (default), psig or %-value of full-scale) can be adjusted via service software PL , Rev05, DCO#

18 4 Operation! WARNING! WARNING Hazardous voltage may be present. Always isolate the electrical power supply before opening the casing. Risk of FIRE! WARNING Not allowed to use with flammable liquids. HARMFUL CHEMICALS may be present. Skin contact and toxic gases may be hazardous to your health. Wear safety gloves and other appropriate safety equipment. PL , Rev05, DCO#

19 4.1 System operating conditions 1) Power up at the main switch 2) Press SEL to turn ON the system 3) At first turn-on procedure, system starts typically in speed mode. Process control mode In this mode a setpoint speed is settable (with or ; e.g rpm) via user interface. 4) Switch to process control : by pressing SEL at the user interface, displays shows processes control? confirm the message by pressing SEL again. Henceforth the system is in process mode and outlet pressure can be adjusted (with or ; e.g. 2 bar) 1) Switch back to speed control : by pressing SEL at the user interface, displays shows speed control? confirm the message by pressing SEL again. Henceforth the system is in speed mode again and setpoint speed can be adjusted Speed control mode (with or ; e.g rpm) 2) Last adjusted value (setpoint pressure or setpoint speed) will be saved and displayed on the user interface when system starts again (value will be written into EEPROM). 3) By pressing CLR for a few seconds system stops immediately. PL , Rev05, DCO#

20 4.2 Priming the Hydraulic Loop Operation Step Priming Description 1. Close the casing lid Make sure that the system connections are leak proofed. 3. Turn ON the system with the Main Power Switch 4. Make sure that facility pressure is present. 5. Open all inlet and outlet facility valves to fill / flush / prime the system with medium (e.g. DI-water) for approximately 2 minutes. 6. If the system is in process control mode change to speed control mode. Turn on the pump (press ) and set the pump speed (with or ; e.g rpm). Wait till medium loop is primed (ca. 30 seconds). 6/7 7. Turn off the pump (press for 2 seconds) 8. System is primed and ready for use. Table 7: Priming the hydraulic loop PL , Rev05, DCO#

21 4.3 Emptying System to Drain Emptying Sequence 1. Turn off the pump (press for 2 seconds) 1 2. Shut off the facility valves 3. Emptying the system must be handled outside the LEVIBOOST system (facility emptying line must be guaranteed in case of service and maintenance. Table 8: Emptying System to Drain PL , Rev05, DCO#

22 4.4 Leak Sensor 1) Leak sensor is installed in the bottom of the hydraulic system. Sensor reacts immediately, if more then 5mm medium is flowing into the cabinet. 2) System shows an error on the LUI (LevitronixUserInterface) and the red control light is activated. System stop s automatically (system needs operator, to remove failure). 1 3) Shut down the system. Leak detection 4) Check system, find and eliminate the leakage. 5) Remove liquid and dry the system. 6) Restart system. 7) Make a visual inspection of hydraulic lines again. 2 8) System is ready for use. PL , Rev05, DCO#

23 4.5 Impeller Replacement For Impeller Replacement follow the instruction in the User Manual of the Pump System BPS-4. PL , Rev05, DCO#

24 5 Troubleshooting 5.1 Malfunction and Leakage If any malfunction, unexpected behavior or leakage is visible press EMO.! WARNING Hazardous voltage may be present. Always isolate the electrical power supply before making or changing connections to the unit.! WARNING HARMFUL CHEMICALS may be present. Skin contact and toxic gases may be hazardous to your health. Wear safety gloves and other appropriate safety equipment. 5.2 Components For troubleshooting of following components use associated user manual: Component Supplier User Manual BPS-600 Levitronix PL Rev03 BPS-600 Manual BPS-4 Levitronix PL Rev06 BPS-4 Manual BPS-600 Impeller replacement BPS-4 Impeller replacement Levitronix Levitronix PL Rev04 Replacement of BPS Impeller LPI-600 PL Rev01 Replacement of Impeller IMP-4 Power supply 48V Lambda RWS600B-48 Instruction Manual Power supply 10V Lambda DSP10-24 / 24V / 10W PL , Rev05, DCO#

25 6 Technical Support For troubleshooting, support and detailed technical information contact Levitronix Technical Service Department: Levitronix Technical Service Department Technoparkstr. 1 CH-8005 Zurich Switzerland Phone for US: Phone for outside US: TechSupport@levitronix.com PL , Rev05, DCO#

26 7 Symbols and Signal Words Symbol / Signal Word Description Type Source DANGER WARNING CAUTION Indication of an imminently hazardous situation that, if not avoided, will result in death or severe injury. Limited to the most extreme situation Indication of a potentially hazardous situation which, if not avoided, could result in death or severe injury. Indication of potentially hazardous situations which, if not avoided, could result in moderate or minor injury. Also alert against unsafe practice. Without safety alert indication of hazardous situation which, if not avoided, could result in property damage. Signal word SEMI S Signal word SEMI S Signal word SEMI S1-0701! Safety alert for Warning and Caution Safety alert SEMI S1-0701! Safety alert for Danger Safety alert SEMI S Toxic material, poison Hazard identification IEC Corrosive material, corrosion Hazard identification IEC General Warning Hazard identification ISO 3864 Flammable Material Hazard identification IEC Strong magnetic field Hazard identification SEMI S Danger: electricity, electrical hazard Hazard identification IEC 61310, ISO 3864 Wear safety gloves Hazard avoidance Mandatory action IEC Wear face shield Hazard avoidance Mandatory action SEMI S Wear safety boots Hazard avoidance Mandatory action IEC Unplug power line Hazard avoidance Mandatory action SEMI S No pacemakers Hazard avoidance Prohibition SEMI S Table 9: Safety symbols and signal words according to SEMI S PL , Rev05, DCO#

Constant and Particle Free Point-of-Use Water Pressure

Constant and Particle Free Point-of-Use Water Pressure Constant and Particle Free Point-of-Use Water Pressure for High Quality UPW and DI-Water Always the right pressure. Higher Cost Pressure and More Rigid Specifications In the Microelectronic world pressure

More information

LEVIFLOW INTEGRATED FLOWMETER LFIF USER MANUAL

LEVIFLOW INTEGRATED FLOWMETER LFIF USER MANUAL LEVIFLOW INTEGRATED FLOWMETER LFIF USER MANUAL LEVIFLOW Integrated Flowmeter: LFIF-06 (10 l/min) This manual contains information necessary for the safe and proper use of the LEVIFLOW LFS flowmeter series.

More information

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications NT High-temperature flowmeter model 4401 Simultaneous flow and pressure outputs for high-temperature applications high-temperature flow measurement Overview Now more than ever there is a need to measure

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

KOBOLD KSM FLOWMETER. User Instructions

KOBOLD KSM FLOWMETER. User Instructions KOBOLD KSM FLOWMETER User Instructions USA 1801 Parkway View Drive Pittsburgh, PA 15205 PH 412-788-2830 Canada 9A Aviation Point Claire, QC H9R 4Z2 PH 514-428-8090 www.koboldusa.com KSM_manual_08-10 Table

More information

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM

More information

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100 Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet

More information

DPC-30 DPC-100. Reference Manual

DPC-30 DPC-100. Reference Manual DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,

More information

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma

More information

RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD - Ultra-Rugged Differential Pressure Flowmeter 0.15-1 to 85-600 GPM Liquids 2.5-25 to 300-1700 SCFM Gases 1/2 to 3 Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available Custom Calibrations

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan SPECIFICATIONS PARTICLE SENSOR KS-18F 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 05083-5E 18-01 Printed in Japan Outline The KS-18F is a sensor which uses the light scattering method

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X

More information

GAS FUEL VALVE FORM AGV5 OM 8-03

GAS FUEL VALVE FORM AGV5 OM 8-03 ALTRONIC AGV5 OPERATING MANUAL GAS FUEL VALVE FORM AGV5 OM 8-03 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY TO OPERATORS

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2 The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

Flow Sensors & Hydrometers Specification Sheet

Flow Sensors & Hydrometers Specification Sheet Baseline Flow s and Hydrometers Baseline s smart flow sensors and hydrometers are two-wire ready flow measurement and control devices that are pre-programmed with the correct K and Offset values. In addition,

More information

AE R1 February 2015

AE R1 February 2015 February 2015 CoreSense Diagnostics for Copeland Scroll UltraTech Air Conditioning Compressors TABLE OF CONTENTS Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to

More information

BGA158 Series CE Approved Class A Shutoff Gas Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

Programmable pressure and temperature transmitters PTM/RS485

Programmable pressure and temperature transmitters PTM/RS485 Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Autocalibration Systems For In Situ Oxygen Analyzers

Autocalibration Systems For In Situ Oxygen Analyzers Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan SPECIFICATIONS PARTICLE SENSOR KS-19F 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 13012-3E 17-06 Printed in Japan Outline The KS-19F is a sensor which uses the light scattering method

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119 Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,

More information

EPP4 Pressure Regulator Basic G 1/4"

EPP4 Pressure Regulator Basic G 1/4 EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard

More information

2/2-Way Proportional Valve (motor-driven)

2/2-Way Proportional Valve (motor-driven) 2/2-Way Proportional Valve (motor-driven) Type 3280 can be combined with Seat valve with stepper motor - actuator isolated from flow path Excellent range (1:100) Low power consumption Fast response Orifice

More information

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S06* Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

Pneumatic Target Transfer System Model PT01

Pneumatic Target Transfer System Model PT01 Pneumatic Target Transfer System Model PT01 Technical Data Sheet ELEX Commerce LLC Bul. M. Pupina 10Z/IV 11070 Belgrade, Serbia www.elexcomm.com February 2018. Page 2/13 REVISION HYSTORY No. Description

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description Smart-Trak Model 100 High Performance Digital Gas Mass Flow Meters and Controllers Features Measure & control gas mass flow rates up to 1000 slpm True digital performance provides high accuracy and great

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

BGA158 Series CE Approved Class B Shutoff Gas Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve Installation Instructions BGA158 Issue Date March 22, 2016 BGA158 Series CE Approved Class B Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated shutoff valve

More information

Quick Installation Guide Doc nr.: C Date:

Quick Installation Guide Doc nr.: C Date: Quick Installation Guide Doc nr.: 9.17.093C Date: 13-05-2016 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION The QB3 is a closed loop pressure regulator consisting of two solenoid valves, internal pressure transducer, and electronic controls mounted to an integrated

More information

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel: PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB Manual #: MM-AD001 12/5/11 Rev. A Page 1 of 8 PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB Manual #: MM-AD001 12/5/11 Rev. A Page 2 of

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

RAM 4021-DPX Operation Manual

RAM 4021-DPX Operation Manual RAM 4021-DPX Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS ABL 4021-DPX / RAM 4021-DPX For Your Safety... 3 Description... 3 Setup Mode... 4 Lights/Alarms... 4 Operation...

More information

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties Quick Installation Guide Doc nr.: 9.17.052H Date: 10-12-2015 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S02 Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141 0 Operation Manual Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and

More information

Glass tube flowmeters Series 2000

Glass tube flowmeters Series 2000 Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve Installation Instructions BGA Series Issue Date October 3, 2017 BGA158, BGA171 and BGA110 Series Shutoff Gas Valve Applications The BGA Series shutoff gas valve is an electrically operated gas valve that

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0578 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

Norrsken Family Booklet

Norrsken Family Booklet Section 1: Introduction Low Energy Designs produce efficient and effective LED based lighting products for commercial, retail and industry purposes. Each product may contain specific details on its operation

More information

Features. Description

Features. Description Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter

More information

Variable Area Flow Meters

Variable Area Flow Meters PDF Published May, 04 Variable Area Flow Meters Chemline F Series Variable Area Flow Meters are ideal for plastic piping. They provide a combination of accurate visual flow rate measurement and clear flow

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4

More information

Electronic gas volume corrector model DGVC-04

Electronic gas volume corrector model DGVC-04 Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector

More information

UltraLo 1800 Alpha Particle Counter

UltraLo 1800 Alpha Particle Counter XIA LLC UltraLo 1800 Alpha Particle Counter Site Requirements & Planning Version: 0.4 Friday, February 15, 2013 Table of Contents I. Site Preparation Tasks... 3 A. Instrument Overview... 3 B. Installation

More information

MoveRoll Conveyor Operating and Maintenance Manual

MoveRoll Conveyor Operating and Maintenance Manual MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.

More information

Programmable Submersible Level Transmitters

Programmable Submersible Level Transmitters Programmable Submersible Level Transmitters PTM/N/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available as

More information

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass

More information

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

D10S/D20S Wall/Post Mount Inflator Quick Start Manual PART NUMBER SERIAL NUMBER D10S/D20S Wall/Post Mount Inflator Quick Start Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product

More information

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT 200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

6890 GC Site Preparation

6890 GC Site Preparation 6890 GC Site Preparation (a16011) This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this material. The information

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information