Saturday Sept 16, 2006

Size: px
Start display at page:

Download "Saturday Sept 16, 2006"

Transcription

1 Saturday Sept 16, 26 Update on hardware 11:55 12:15 Varian V81M released July 26 A replacement for the V7LP V81M (not V81T) 5% reduction in power. -lower bearing temperature. Slightly higher pump speed. Higher tolerance to foreline pressure. All future AMS systems will use the V81 1

2 Comparison of pumping speed for V7LP and V81M Pump Pin (mbar) Power (W) S (L/s) V7LP 75k 7.52x N2 V 81-M-75k 7.52x V 81-M-8k 6.98x V7LP 9.71x He V 81-M 7.84x Ar V 81-M 7.13x Data from Varian V81M Upgrade Issues Varian has an upgrade program to exchange a V7LP for a new V81M. New V7LP pumps are no longer available but rebuild/exchanges are still supported. Electrical and roughing port are the same style and location as V7LP. V81 does require a new cooling fan mounting bracket. The V81 PCB controller has the same electrical connections and mounting holes as the V7 PCB controller. The V7 PCB controller WILL drive the V81M pump at slightly reduced speed (75 KRPM vs 8 KRPM). 2

3 Operating with V7 controller will slightly reduce best performance V 81-M: Compression ratio 1.E+1 1.E+9 8 KRPM 1.E+8 1.E+7 Compression ratio 1.E+6 1.E+5 1.E+4 75 KRPM 1.E+3 1.E+2 1.E+1 1.E+ 1.E-1 1.E+ 1.E+1 1.E+2 Foreline pressure (mbar) Ar N2 N2-75 He Data from Varian New Pump Controller Interface Improved control and diagnostics of the vacuum pump system Diaphragm pump Turbo Pumps Total DC current consumption Inlet pressure (auto start) PC control through USB with data logging capability Older systems are upgradeable 3

4 G1 aircraft ctof with new pump control system Controller has a 4x2 character LCD with a 3-fxn data entry knob and a USB port for PC control. Successfully operated on G1 aircraft in MaxMex 26 Turbo Pump Status and Error Messages Pump status, pump speed, bearing temperature (and controller), and current are continuously updated. Pumps Status Stopped Interlock Starting Auto Tune Braking Normal Error Pump Errors No connection Pump over temp Controller over temp Power fail Normal start fail Soft start fail Short circuit Too high load 4

5 PC Software interface for Pump Controller Pump Current (ma) Pump Current P2 V31 P3 V7 P4 V7 P5 V31 P6 V7 Diagnostic plots 11: AM 1/19/26 12: PM 1: PM 2: PM 3: PM 4: PM 5: PM Date/Time PumpStats_Jan19.pxp 35 Pump Temp (C) MD1Spd P(torr) : AM 1/19/26 P2 V31 P3 V7 P4 V7 P5 V31 P6 V7 12: PM 1: PM 2: PM 3: PM 4: PM 5: PM Date/Time PumpStats_Jan19.pxp BoxTemp TotalAmps Baratron C:\DATA PARTY\FieldWork\G1_Veracruz6\G1TestFlight_Pasco6 MD1Speed Pump 3 runs warmest Pump 3 has highest failure rate TotAmps 1 BoxT(C) : AM 1/19/26 12: PM 1: PM 2: PM 3: PM 4: PM 5: PM Date/Time PumpStats_Jan19.pxp 5

6 Consider Water Cooling Turbos in Warmer Operating Environments Since we now know that P2 (V31) and P3 (V7) run warmest water cooling these may be beneficial. Water cooling all turbos is probably not necessary. Startup behavior Pump Current (ma) Pump Current P2 V31 P3 V7 P4 V7 P5 V31 P6 V7 22 1:4 AM 1/19/26 1:42 AM 1:44 AM 1:46 AM 1:48 AM 1:5 AM Date/Time PumpStats_Jan19.pxp P5 load increases when filaments are turned on Fil ON Pump Current (ma) Vaporizer on Pump Current P2 V31 P3 V7 P4 V7 P5 V31 P6 V7 1:3 AM 1/19/26 11: AM 11:3 AM 12: PM 12:3 PM Date/Time PumpStats_Jan19.pxp 6

7 Electronics needs to be redesigned for TOF systems Only chopper, vaporizer and heater bias are need for TOF Power supply can be redesigned for TOF system 24 VDC supply (4A) in a 1U RM size 7

8 Constant Pressure Inlet System Important for use on aircraft. Eliminates variation of particle velocity and particle transmission calibration as lens pressure changes with altitude. Past and current efforts have been made by Ann Middlebrook (P3) Jose Jimenez (C-13/HIAPER) Jonny Crosier (BA 146) J. Jayne (G1) Compact pressure controller system Houses small pump, electronic valve and PID controller 8

9 Calculated Pressure Altitude relationship 6x1 3 Altitude, ft HIAPER_maxAlt MexCity_Alt_ft G1_alt 1 1 2x Pressure, torr SeaTacFlightMex26.pxp G1 Max. altitude 17, ft ~42 torr (for MaxMex) HIAPER max. altitude 51, ft Schematic of test setup to evaluate pinhole sizes, pressures and flows P1 P2 4 torr ~= 17K ft P3 Standard Lens 13 um SPI #8 Okeefe Regulate P1 to 1.3 torr Controller acts on lens pressure Proportional Solenoid / PID control KNF UNMP5 pump Needle valve to simulate altitude Flow measurement Feb 4, 26 Okeefe # cc/m measured under choke flow conditions For Plens=1.28 torr (controller set point), P2 =42 torr. 9

10 Evaluation of pressure regulation range Flow (cc/min) um, Set point=1.26 Plens_b #1 Okeefe Plens_c #5 Okeefe Plens_d #8 Okeefe. Plens_e #16 Okeefe Flow_d #8 Okeefe 1.8 P lens (torr) P ambient (torr) I choose the green points, Okeefe #8 Aerosol transmission tests were performed using this plumbing arrangement. QAMS, standard lens, 215 series chamber. From DMA/dilution system 13 um SPI.8 Okeefe 1

11 Collection efficiency measured by direct count method. 1 AMS (#/cc) Dmob NH4NO3 (1.41 torr lens, 13um SPI) ams_3nm ams_35nm ams_4nm ams_25nm ams_2nm 1:1 line unkown Okeefe measure 353 cc/m = #8 (.8") CPC (#/cc) Used QAMS standard lens, 215 series chamber, Pressure Controlled inlet, Plens=1.41 torr. The two plots are the same data, one has normalized Y-axis Collection efficiency. Measurement of polydisperrse NH4NO3 using standard 1um pinhole assembly and pressure controlled inlet. Aerosol concentration kept ~constant at (3.5-4.)e4/cc. This figure suggests that there are no significant losses in PC inlet. Sig_p46 Avg Standard 1 um pinhole 5 Sig_p46_R231_R23_avg Press Controlled Okeefe Hi 4 Sig_p46_R234_R235_Avg 4 Press Controlled Okeefe Low 4 Sig_p46_R228_R Dva 6 Polydisperse NH4NO3 sampled by 3 different configurations: 5 4 Standard 1 um pinhole Sig_p46_R231_R23_avg Press Controlled Okeefe Hi Sig_p46_R234_R235_Avg Press Controlled Okeefe Low Sig_p46_R228_R233 1) Standard 1um pinhole assembly 2) 13 um pinhole with Okeefe ¼ tube orifice at upstream end (high) Sig_p46 Avg 3 2 3) 13 um pinhole with Okeefe ¼ tube orifice at downstream end Dva 11

12 Pressure Controller Summary Determine lowest pressure range for operation select pinholes and pump. Use the lens pressure as the pressure to regulate. Eliminates a second pressure gauge For sampling pressures >~4 torr losses seem to be small. For sampling pressures <~4 torr losses may be significant. Need to design better sampling interface to minimize losses. Application: tunable pressure lens Direct Probe GC Inlet Designed for Dr. Akiama at Japanese Automobile Research Institute (JARI) Allows use of TOF spectrometer to measure effulents from GC capilary column 12

13 Cartridge heaters inserted in this block St. St 3/4OD tube for thermal isolation Teflon ferrule used here Copper-Stainless steel braze joint Thermal isolation 24 gauge (.16 ID x.22 OD) st. st. capillary tube extends from GC column connector thru the entire length of the copper rod, makes a 9 degree bend upwards to direct fused silica column effluent to ionizer. The silica column is inserted into the st. st. column which provides ease of assembly, alignment and (good?) thermal contact with the heated copper pieces. GC column connector St. st. capillary column extends to the face of this connector 13

14 Two step insertion process. Insert probe from the rear with vertical copper piece removed. Vertical copper rod is installed after inserting probe. Note steel capillary tube is bent horizontal for insertion from rear of AMS. Vertical copper rod is installed from top of chamber, access thru VUV port is helpful. Note steel capillary tube is now vertical, directing gas to ionizer. Stainless Steel capillary 24 gauge..16 ID x.22 OD (hard to see in photo) Make No contact between copper rod and Al. cylinder Thermocouple location for temperature regulation 14

15 Slide GC column inside of steel capillary column until it won t go any further this is where the st. st. column bends 9 deg. Upward into ionizer. Hand tightened brass nut with vespel ferrule for a leak tight seal. I used an RGA on detection chamber to test for leaks as the system was heated Flow measures 17.6 cc/min at entrance end of column. V31 at.88 amps ok (.34 amps no load) 15

16 Heating scheme. Two cartridge heaters (3/16 OD x 1.5 L 2 W 12 VAC ) inserted into copper block. With insulation, achieved 18C. Need a bit more power will get new higher power heaters. No leaks These 2W heaters have been replaced with two 1W ¼ OD heaters.plenty of power PID controller ¾ OD St.St. tube thermally isolates from chamber. Nov. 29, 25 1W heaters tested max temperature tested was 25C. Measuring of temperature gradient between heater block and probe temperature. For temperatures >2C you may need to cool the ¾ St. St. tube with either a heat sink or a small fan. 16

17 Minimal temperature losses 3 25 This shows that there is essentially no temperature gradient between the heater block and the probe temperature, ie no heat losses. Initial set pt was 1C. Changed to 25, which also equilibrated (but not shown). Note large overshot on heating block...the PID algorithm needs to be tunned (see Newport controller manual for proceedure). temp (C) 2 15 T_Probe T_Block 1 Controller Set Point = point number (~time) Dr. Akiama s Direct Probe results with VUV photo ionization.1.1 Response (a) Acenaphthylene Response (d) Chrysene Retention time (min) m Retention time (min) m Response (b) Fluorene Response (e) B[a]P Retention time (min) m166.1 Response Retention time (min) m (c) Phenanthlene (f)b[g,h,i]p Response Retention time (min) m Retention time (min) m276 17

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere! The portable Gas Chromatograph is now more versatile than ever. DPS Instruments is pleased to present the newest Portable Companion 2 Gas Chromatograph with room for 2 Detectors. The Companion 2 GC was

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1 Project: Novel Electron Bubble Particle Detector Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat Version 5.1 (Using side filling line) Hand Processed Changes HPC No. Date

More information

DART-Bruker Vapur Interface Manual SI-410-A-R Rev 1-3

DART-Bruker Vapur Interface Manual SI-410-A-R Rev 1-3 DART-Bruker Vapur Interface Manual SI-410-A-R Rev 1-3 For All Bruker Mass Spectrometer Models (Except Bruker Esquire) Rev 1 Document # 7.5.060 IonSense Inc. 999 Broadway Suite 404 Saugus, MA 01906 Copyright

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications. OMNISTAR / THERMOSTAR The efficient solution for gas analysis. Intelligent software. Wide range of applications. OMNISTAR /THERMOSTAR The efficient solution for gas analysis. Intelligent software. Wide

More information

Mass Spec will not Autotune

Mass Spec will not Autotune Mass Spec will not Autotune Applies to 5973A/N MSD What could be the problem? There could be several things that would cause your Mass Spec not to Autotune. The most common, easily corrected Autotune problems

More information

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum. This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum. Specifically, today s talk will cover: Brief review of Vacuum Fundamentals Applications Using Rough Vacuum Rough

More information

Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No

Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No Rev. ECO Description Checked Approval Date 01 32- Release M. Smith Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System Dwg. No. 32-06003.05 Revision 01 June 18, 2007 1 1. Introduction 1.1.

More information

Some tentative AMS improvements (and a note on IE calibrations)

Some tentative AMS improvements (and a note on IE calibrations) Some tentative AMS improvements (and a note on IE calibrations) Pedro Campuzano Jost University of Colorado, Boulder AMS Users Meeting Outline Integrating a Cryopump in an aircraft AMS: First notes on

More information

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma

More information

Series Environmental Chambers

Series Environmental Chambers 3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable

More information

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more! After years of development and testing, DPS Instruments is pleased to present the newest, most expandable and versatile Gas Chromatography Systems in history. The DPS 600 Series GC systems are the world

More information

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware 57007-88 Introduction Safety Precautions This instruction sheet describes how to set up and use the Hach (Figure 1). A water weir is a device that raises or diverts water to regulate the flow. Hach s water

More information

Microscopy Cryogenic WORKSTATION. Performance by Design

Microscopy Cryogenic WORKSTATION. Performance by Design CRYO Microscopy Cryogenic WORKSTATION Optical cryostat for use in microscopy and spectroscopy Performance by Design RC102-CFM Microscopy Cryostat offers fast cooldown, high efficiency, excellent temperature

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

Mass Spec will not pump down

Mass Spec will not pump down Mass Spec will not pump down Applies to 5973A/N MSD There are several situations that could cause the 5973A/N to have problems pumping down. The following scenarios should help in isolating problems related

More information

Constant Pressure Inlet (CCN) Operator Manual

Constant Pressure Inlet (CCN) Operator Manual Constant Pressure Inlet (CCN) Operator Manual DOC-0125 Revision J 2545 Central Avenue Boulder, CO 80301-5727 USA C O P Y R I G H T 2 0 1 1 D R O P L E T M E A S U R E M E N T T E C H N O L O G I E S, I

More information

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric

More information

Model 2200 Toxic Air Sampler. Operations and Maintenance Manual

Model 2200 Toxic Air Sampler. Operations and Maintenance Manual Model 2200 Toxic Air Sampler Operations and Maintenance Manual Version 2.00 March 7, 2014 2014 ATEC, 9727 Cotharin Road, Malibu, CA 90265-2112 ATEC Model 2200 Toxic Air Sampler Limited Warranty Atmospheric

More information

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters

More information

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow Model: FP 450-80 Installation Operation Maintenance PAGE 1 OF 5 1. Safety First BERMAD believes that the safety of personnel

More information

Model 3400 Toxic Air Sampler. Operations and Maintenance Manual

Model 3400 Toxic Air Sampler. Operations and Maintenance Manual Model 3400 Toxic Air Sampler Operations and Maintenance Manual Version 1.40 June 17, 2007 2007 ATEC, 9727 Cotharin Road, Malibu, CA 90265-2112 ATEC Model 3400 Toxic Air Sampler Limited Warranty Atmospheric

More information

Section 3- Repair and Calibration Procedures

Section 3- Repair and Calibration Procedures Section 3- Repair and Calibration Procedures 1. Refrigerant Removal Procedures 2. Scale/PC Board Recalibration Procedure 3. PC Board Configuration Procedure of AR400 4. Scale Tare Procedure 5. Gauge Calibration

More information

Agilent ICP-MS Interactive Troubleshooting tool for Plasma ignition problem

Agilent ICP-MS Interactive Troubleshooting tool for Plasma ignition problem Agilent ICP-MS Interactive Troubleshooting tool for Plasma ignition problem Rev. B 2017, January, 20 Next > Preconditions 7900, 7800, 7700, 8800, or 8900 ICP-MS is used. Sample introduction type is PeriPump.

More information

Model 601CV. Mass Flow Controller. Product Features:

Model 601CV. Mass Flow Controller. Product Features: Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass

More information

Agilent G3180B Two-Way Splitter Kit

Agilent G3180B Two-Way Splitter Kit Agilent G3180B Two-Way Splitter Kit With Makeup Gas Installation and Operation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid

More information

Gun Vacuum Performance Measurements February 2003

Gun Vacuum Performance Measurements February 2003 JLAB-TN-03-013 Gun Vacuum Performance Measurements February 2003 Marcy Stutzman Abstract. The vacuum in the polarized photoguns at Jefferson Lab is crucial to long lifetime operation of the polarized source.

More information

Models 106-RF / 206-RF Rate of Flow Control Valve

Models 106-RF / 206-RF Rate of Flow Control Valve Rate of Valve KEY FEATURES Accurately limits low to a pre-set maximum Easily adjustable low limit Paddle-style oriice plate included Optional oriice plate housing 106-RF Globe Product Overview The 106-RF

More information

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual 30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see mvx Principles of Operation VX No moving parts to wear or fail. Electronics can be remotely mounted up to 30.5 m (0 ft). No fluid

More information

User s Guide. Vacuum Controller for liquid delivery systems

User s Guide. Vacuum Controller for liquid delivery systems Flow Control User s Guide Vacuum Controller for liquid delivery systems Precise Vacuum Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery

More information

Installation, use and maintenance instructions. Gas burner (5)

Installation, use and maintenance instructions. Gas burner (5) Installation, use and maintenance instructions Gas burner MODEL GAS 4 TYPE 516 T80 291 (5) TECHNICAL FEATURES Thermal output 180-470 kw 154.800-404.200 kcal/h Fuel Natural gas Pci 8-10 kwh/m 3 = 7000-8600

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Met One E-BAM Particulate Monitor

Met One E-BAM Particulate Monitor STANDARD OPERATING PROCEDURES Met One E-BAM Particulate Monitor AMBIENT AIR MONITORING PROGRAM for the 130 LIBERTY STREET DECONSTRUCTION PROJECT LOWER MANHATTAN DEVELOPMENT CORPORATION 1 Liberty Plaza

More information

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features ANALOG MASS FLOW CONTROLLERS Model AF mass fl ow controllers are designed to indicate fl ow rates and control set fl ow rates of gases. Each of these units incorporates an advanced straight tube sensor

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel: PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

UltraLo 1800 Alpha Particle Counter

UltraLo 1800 Alpha Particle Counter XIA LLC UltraLo 1800 Alpha Particle Counter Site Requirements & Planning Version: 0.4 Friday, February 15, 2013 Table of Contents I. Site Preparation Tasks... 3 A. Instrument Overview... 3 B. Installation

More information

Installation and Use Manual

Installation and Use Manual Installation and Use Manual EMASMB & LMASMB Surface Mount Bottle Filling Stations Model EMASMB IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL.

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 3-2 Orifice Plates EXERCISE OBJECTIVE In this exercise, you will study how differential pressure flowmeters operate. You will describe the relationship between the flow rate and the pressure drop

More information

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no

More information

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Vaccon offers a High Vacuum Venturi Pump in a variety of performance ranges. Each HighVac Series Pump is capable of 29.5 Hg [999mbar]

More information

5 Channel Calibrator

5 Channel Calibrator 212 N. Woodwork Lane Palatine, IL 60067 800-223-3977 5 Channel Calibrator Part # 0724 User Manual Questions? Contact us at 800-223-3977 or online at http://www.cleanair.com/equipment/express/main.html

More information

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv CAT.ES-173 A Air Saving Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction ratio (%) 3 1.1.1...3 pressure

More information

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A) Purpose of Procedure Your site must meet this specification or set of requirements to assure a successful and timely installation of your 7820MSD Series Mass Selective Detector (MSD). This checklist is

More information

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

TEK-THERMAL 1700B. Thermal Mass Flowmeter.   FLOW. Technology Solutions Technology Solutions TEK-THERMAL 1700B Thermal Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Thermal 1700B Thermal Mass Flowmeters,

More information

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Technical Specifications of Hydrogen Isotope Handling and Recovery System SECTION - C TECHNICAL SPECIFICATIONS OF STORES AND DRAWINGS. Technical Specifications of Hydrogen Isotope Handling and Recovery System INSTITUTE FOR PLASMA RESEARCH GANDHINAGAR, GUJARAT 382428 ANNEXURE-I

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic

More information

differential pressure regulating valve - threaded

differential pressure regulating valve - threaded 140-142 differential pressure regulating valve - threaded Introduction Differential pressure regulating valves (DPRV) maintain the differential pressure across a circuit or sub-branch at a set differential

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

Kube Engineering Quinn E. Eddins, B.S.E.E Phone

Kube Engineering Quinn E. Eddins, B.S.E.E Phone Process Information: There are four ph assemblies used to monitor the ph value on a Sulfur Dioxide absorber. The chemical composition is approximately 20-30% Sodium Bisulfite, 4% Sodium Sulfite, and the

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

Glove Box Installation Manual

Glove Box Installation Manual Glove Box Installation Manual 1998 by M. Braun Company File: GB-UNI-INS.DOC! Edition 08-00 by M. Boutin! Subject to be changed without notice Glovebox Installation Your Glove box has been fully assembled,

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120 MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120 QUICK START GUIDE P/N 6006154, REVISION C MAY 2013 Model 8120 Mask Integrity Tester is patented under U.S. Patent No. 8,312,761. Additional patents are pending.

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

Gas Leak Measurement of TRT Barrel Module

Gas Leak Measurement of TRT Barrel Module DUKHEP01-07-02 Gas Leak Measurement of TRT Barrel Module Shannon Watson, Seog Oh Department of Physics Duke University Durham, NC, 27708, USA 1. Introduction One of the requirements for the TRT module

More information

Chapter 10: Bidirectional Flow Controls

Chapter 10: Bidirectional Flow Controls Chapter 10: Bidirectional Flow Controls Objectives Learn about the patented, bidirectional flow control valves. Understand how the flow force affects the performance of the ZL70-36. Learn why there is

More information

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual 30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Connecting a SSL/PTV Backflush System

Connecting a SSL/PTV Backflush System This section provides instructions for connecting your SSLBKF/PTVBKF injector modules with pre-column and analytical capillary column into the oven. Refer to the chapters SSLBKF Injector Module and PTVBKF

More information

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller w w w. m k s i n s t. c o m Pressure & Vacuum Measurement Solutions Series 370 Stabil-Ion Vacuum gauge and Controller Features & Benefits All-metal, rack-mount controller for Stabil-Ion and Convectron

More information

Model 8000 Automated Sampler. Operations and Maintenance Manual

Model 8000 Automated Sampler. Operations and Maintenance Manual Model 8000 Automated Sampler Operations and Maintenance Manual Version 20.00 March 19, 2014 2014 ATEC, 9727 Cotharin Road, Malibu, CA 90265-2112 ATEC Model 8000 Toxic Air Sampler Limited Warranty Atmospheric

More information

Model PDT Dewpoint Transmitter

Model PDT Dewpoint Transmitter Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

Major Design Features

Major Design Features Major Design Features 3Flex Features Design Benefits Discussion 316 SS fittings and pneumatically actuated, hard-seal valves Provides virtually leak-free gas management with the lowest outgassing rate

More information

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information CS-425-01 Controlled Dissolved Gas assembly with optional CS-603-01 Air Aspirator assembly Installation and Operation information Serial # CS-XXX Date of shipment:, 2005 Shipped to: Purchase order #: xxxxxxx

More information

VB-7263 Series. Application. Features. Applicable Literature

VB-7263 Series. Application. Features. Applicable Literature TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com VB-7263 Series 1/2" to 2" Screwed NPT Stainless Steel Trim with Teflon Disc Stem Up Closed, Two-Way Valves General Instructions

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

Universal Gas Analyzers for Process Monitor (UGAPM) UGAPM100, UGAPM200, UGAPM300

Universal Gas Analyzers for Process Monitor (UGAPM) UGAPM100, UGAPM200, UGAPM300 Operation Manual and Programming Reference Universal Gas Analyzers for Process Monitor (UGAPM) UGAPM100, UGAPM200, UGAPM300 Stanford Research Systems Revision 1.1 May, 2014 Certification Stanford Research

More information

Installation Operation Maintenance

Installation Operation Maintenance 682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass

More information

The Open-Split Capillary Interface. Part No

The Open-Split Capillary Interface. Part No The Open-Split Capillary Interface Part No. 113532 2 INTRODUCTION With the advent of fused silica capillary columns and their high degree of flexibility, it is obviously attractive to be able to take the

More information

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8 and 1/4 PTF Port Sizes. Air line equipment. Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass

More information

The Broadest Gauging Line in the Industry

The Broadest Gauging Line in the Industry The Broadest Gauging Line in the Industry Vacuum Measurement Varian s broad line of vacuum gauge controllers and gauge tubes are the most reliable, accurate, and economical means of measuring, monitoring,

More information

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 5975C MSD Series G3170A, G3171A, G3172A, G3174A

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 5975C MSD Series G3170A, G3171A, G3172A, G3174A Purpose of Procedure Your site must meet this specification or set of requirements to assure a successful and timely installation of your 5975C Series Mass Selective Detector (MSD). This checklist is designed

More information

Full-Vacuum Chlorinator C 2212 MB / 1

Full-Vacuum Chlorinator C 2212 MB / 1 MB 2 04 12 / 1 Purpose of full-vacuum chlorinators Chlorine gas is important for the disinfection of potable and swimming pool water but also represents a source of danger as far as handling, transportation

More information

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual BioAerosol Nebulizing Generator Operation and Maintenance User Manual INTRODUCTION The BANG or BioAerosol Nebulizing Generator is a unique nebulizer for the generation of aqueous aerosols at a low air

More information

Rapidmain Installation Guide

Rapidmain Installation Guide Rapidmain Installation Guide Aluminium Compressed Air Pipe Work Installation Guide Trafalgar Court, Waterloo Ind Estate, Widnes Cheshire. UK. Ref: Rapidmain installation guide 4b Index 1. Rapidmain fittings:

More information

6200E Installation Requirements

6200E Installation Requirements Requirements When purchasing a standalone 6200E unit with the calibrator, the analyzer will be supplied as three 19 rack mount units. Analyzer Converter Calibrator Included with the unit are two lengths

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous

More information

FX134, FX1234, FX3030 Problem and Solutions

FX134, FX1234, FX3030 Problem and Solutions FX134, FX1234, FX3030 Problem and Solutions Unit Will Not Power Up Turn the power switch on. The unit LCD will display revision program and filter life within 3 to 5 seconds after turning on unit. If this

More information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

Angstrom Dielectric Sputterer Operation Manual

Angstrom Dielectric Sputterer Operation Manual Angstrom Dielectric Sputterer Operation Manual I. System overview The Angstrom Dielectric Sputterer (ADS) has a similar interface as the Angstrom metal sputterer. It has two screens, the process screen

More information

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New > Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,

More information

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01 INAOE. Tonantzintla, Mexico. 2010-06-23. June 23 rd, 2010 Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01 Joel Molina INAOE Microelectronics Group jmolina@inaoep.mx 1 Vacuum

More information