Arterial Spin Labelling: Non-invasive measurement of perfusion

Size: px
Start display at page:

Download "Arterial Spin Labelling: Non-invasive measurement of perfusion"

Transcription

1 Arterial Spin Labelling: Non-invasive measurement of perfusion Michael A. Chappell Institute of Biomedical Engineering & Oxford Centre for Functional MRI of the Brain University of Oxford.

2 Perfusion Perfusion is a measurement of delivery of blood to capillary bed Related to nutrient delivery to cells and waste removal. Altered by task activity. Changes in disease. Quantity of blood delivered per unit of tissue per unit of time ml blood / 100g tissue / min (Dimensions of [T] -1 ) Grey matter magic number: 60 ml/100g/min Cerebral Blood Flow (CBF) is a misleading name! To image perfusion we need a tracer.

3 FSL for Arterial Spin Labelling BASIL: a toolset for resting ASL quantification: CBF quantification. Calibration / M0 estimation Registration. Partial volume correction. Command line tools oxford_asl, basil, asl_reg, asl_calib Graphical User Interface asl_gui NEW VERSION! available as a pre-release - you will be using this version on the course.

4 What Have I Got Here!? What I have... What I want... What should I do? I just want to do something simple/easy! I must have absolute perfusion (ml/100g/min) Command line instructions here for future reference...

5 Outline Acquisition Keep it simple! Perfusion weighted images. Quantitative perfusion: Kinetics: A short course in tracer kinetics. Calibration: Measuring arterial blood magnetization. Preparing for group analysis. Advanced quantification: Distortion Correction Macro vascular contamination Partial Volume Correction

6 Arterial Spin Labelling A tracer experiment with an endogenous tracer - blood water. LABEL CONTROL Aquire image of brain Wait for blood to reach brain Label blood by magnetic inversion

7 Spot the difference? LABEL ASL Acquisition CONTROL Perfusion is ~60 ml/100g/min = 0.01 s -1 Signal is ~ 1-2%

8 Nuts & bolts: Labelling pasl: Pulsed ASL ASL Acquisition casl: Continuous ASL pcasl: psuedo-continous ASL Label a region in a single pulse Label blood by magnetic inversion Label blood flowing through a plane for some time pcasl uses pulses and is more widely available

9 ASL Nuts & bolts: Inflow time Acquisition casl/pcasl Wait for blood to reach brain Label blood by magnetic inversion casl label pasl label pasl Post-labeling delay (PLD) imaging time imaging Inversion time (TI) time

10 Nuts & bolts: Bolus/label duration ASL Acquisition Wait for blood to reach brain Label blood by magnetic inversion Label duration (τ) pasl label casl label TI1 pcasl Post-labeling delay (PLD) pasl QUIPSS II imaging time imaging pasl Label duration is undefined in pasl. QUIPSSII pulses cut off the end of the labeled bolus. Inversion time (TI) time

11 Nuts & Bolts: Readout ASL Acquisition Aquire image of brain Wait for blood to reach brain Label blood by magnetic inversion EPI (stack of 2D slices) Different PLD/TI for each slice GRASE/RARE (3D) Higher SNR Long echo-train: blurring Pre-saturation Saturate static signal at start of TR Background suppression Null static signal - reduce physiological noise

12 ASL Acquisition The ASL white paper - a good place to begin: Use pcasl where possible Label duration 1800 ms Post labeling delay ~1800 ms Otherwise pasl with QUIPSSII Inversion time ~1800 ms TI1 of 800 ms Slab thickness cm Ideally 3D readout. 2D EPI an acceptable alternative. Resolution: 3-4 mm in plane. 4-8 mm through plane. Use background suppression. Recommended Implementation of Arterial Spin Labeled Perfusion MRI for Clinical Applications: A consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia Magnetic Resonance in Medicine - 73 (1) p , 2015.

13 Outline Acquisition Keep it simple! Perfusion weighted images. Quantitative perfusion: Kinetics: A short course in tracer kinetics. Calibration: Measuring arterial blood magnetization. Preparing for group analysis. Advanced quantification: Distortion Correction Macro vascular contamination Partial Volume Correction

14 What I have... ASL data! Example (simple) Control Tag (labelled) Perfusion (difference) What I want... A perfusion image (in this subject). What should I do? Label-control subtraction Average Tissue + blood - = Tissue - blood 2 * blood asl_file --data={asldata.nii.gz} --ntis=1 --iaf=tc --diff --out={diffdata.nii.gz} asl_file --data={asldata.nii.gz} --ntis=1 --iaf=tc --diff --mean={diffdata_mean.nii.gz}

15 Outline Acquisition Keep it simple! Perfusion weighted images. Quantitative perfusion: Kinetics: A short course in tracer kinetics. Calibration: Measuring arterial blood magnetization. Preparing for group analysis. Advanced quantification: Distortion Correction Macro vascular contamination Partial Volume Correction

16 Example What I have... ASL data (calibration images) What I want... Perfusion in ml/100g/min - = What should I do? Label-control subtraction. Kinetic model inversion. M0 calculation.

17 Introduce tracer Kinetic Model Inversion Tissue (voxel) Arterial Input Function Residue Function ΔM(t) = F AIF(t) * r(t)

18 Kinetic Model Inversion Arterial Input Function Tracer conc n Tells us about the delivery of the tracer Time

19 Kinetic Model Inversion LABEL AIF T1 decay Tissue (voxel) Parameters: Arterial Transit time Bolus duration T1 decay (in blood) pasl

20 Kinetic Model Inversion LABEL AIF T1 decay Tissue (voxel) Parameters: Arterial Transit time Bolus duration T1 decay (in blood) casl/pcasl

21 Kinetic Model Inversion Residue Function 100% Tells us what happens to the tracer after is has arrived. Tracer Remaining time

22 Kinetic Model Inversion Rapid exchange: single well mixed compartment No spins leave the compartment Decay with T1 r(t) Well mixed T1 decay Parameters: Arterial Transit time Bolus duration T1 decay (in blood)

23 Kinetic Model Inversion LABEL T1 decay Well mixed AIF r(t) * M(t) = Parameters: Perfusion - F Arterial Transit time Bolus duration T1 decay (in blood) ΔM(t) = F AIF(t) * r(t)

24 Kinetic Model Inversion Arterial Input Function Residue Function Concentration time curve time time

25 Kinetic Model Inversion LABEL T1b decay The simple model Only one T1 value (blood) Well mixed T1t decay 1 :/ / I Spins never leave tissue The standard model: Separate T1 for blood and tissue (T1t < T1b). Spins leave voxel at rate determined by perfusion and partition coefficient. r(t) T1 (set) Time (sec) r(sec) Buxton et al., MRM 40(3), 1998.

26 What I have... ASL data (calibration images) What I want... Perfusion in ml/100g/min Example What you need to know about your data: Labeling pasl (pulsed) Inversion time(s) Bolus duration (if QUIPSS/Q2TIPS) or pcasl (continuous) Post-labeling delay(s) Labeling duration What should I do? Label-control subtraction. Kinetic model inversion. M0 calculation. Reado ut Model 3D/2D (slice timing) T1 (tissue and blood) Arterial Transit time oxford_asl -i {asl_data} -o {output_dir} --iaf={tc} {--casl} --tis={list_of_tis} bolus={bolus_duration} slicedt={time_per_slice} {model/analysis options}

27 assumption is not likely to be strictly 2. Labeled blood water is well mixed with tissue before outflow occurs Because the tissue water pool is much larger than the blood water pool,which and water assumption, are related to th exchange between blood and tissue is rapid, this is typically good assumption are typicallya relatively small. (Zhou J, Wilson D, et al. JCBFM, 21:440, 2001). Under these assumptions CBF in each vo Kinetic Model Inversion 3. The relaxation of the labeled spins are governed by blood T1. While this!"#!"""! (!"!!" assumption is not likely to be strictly true, the errors introduced by!"#$! this)!!!,!"##$!"#$%!" Analytical solutions - Simple model (ASL white paper ): CBF =![ml/10!! assumption, which are related to the difference in T1 between blood and tissue,!!!!!,!"##$!"!" (!!!!,!"##$ ) are typically pcaslrelatively small. pasl QUIPSS II and for QUIPSS II PASL using (37): Under these assumptions CBF in each voxel can be calculated for PCASL using (10): CBF =!"""! (!"!"#$%!"!!"!"#$!!!!!,!"##$!"!" (!!!!"#!!,!"##$ )!!!!!,!"##$ )![ml/100!g/min] CBF =!"""! (!"!"#$%"&!!"!"#$! )!!!!"!!"!"!"!!,!"##$![ml/10 where λ is the brain/blood partition coeffici and for QUIPSS II PASL using (37):!" averaged intensities in theimaging control a Post-labeling!!,!"##$ Label duration (τ) imaging pasl label signal QUIPSS II!"""! (!"!"#$%"&!!"!"#$! )! delay (PLD) CBF =![ml/100!g/min] longitudinal TI1 relaxation time of blood in sec!!!"!" casl label!!" signal intensity ofsialabel proton density where λ is the brain/blood partition coefficient in ml/g, SI are the time- weighte control and time time averaged signal intensities in the control and tag images respectively, and TI1 are as defined above. The factor blood is the Inversion timet1,(ti) longitudinal α=0.85 relaxation time of blood in seconds,ml/(100g)/min, α is the labelingwhich efficiency, SIPD is the in the p is customary α=0.98 signal intensity of a proton density weighted image, and τ is the label duration. PLD,inTICBF qu summary of parameters for use and TI1 are as defined above. TheFixed factor value: of 6000 converts the units from ml/g/s to II modification cannot be reliably T1bloodin=the 1650 msquipss (3T) literature. ml/(100g)/min, which is customary physiological See Table 3 for a Assumes AAT = 0 Single TI PASL without the summary of parameters for use in CBF that quantification. Arterialintensities Spin Labelling of : M.A. Chappell To scale the signal the subtra QUIPSS II modification cannot be reliably converted into CBF. signal intensity of fully relaxed blood spins To scale the signal intensities of the subtractedyield ASL-images to absolute CBF units, estimates of this value, we the recomme

28 What I have... ASL data (calibration images) What I want... Perfusion in ml/100g/min Example pcasl with labeling duration: 1.8 s post-label delay: 1.8 s 2D readout 45.2 ms per slice Assume white paper T1 : 1.6 s ATT : 0 s What should I do? Label-control subtraction. Kinetic model inversion. M0 calculation.

29 What I have... ASL data (calibration images) What I want... Perfusion in ml/100g/min Example pcasl with labeling duration: 1.8 s post-label delay: 1.8 s 2D readout 45.2 ms per slice Assume white paper T1 : 1.6 s ATT : 0 s What should I do? Label-control subtraction. Kinetic model inversion. M0 calculation. #Do label control subtraction asl_file --data={asldata.nii.gz} --ntis=1 --iaf=tc --diff --out={asldiffdata.nii.gz} \ --mean={asldiffdata_mean.nii.gz}

30 Example pcasl with labeling duration: 1.8 s post-label delay: 1.8 s 2D readout 45.2 ms per slice Assume white paper T1 : 1.6 s ATT : 0 s #Do label control subtraction > asl_file --data={asldata.nii.gz} --ntis=1 --iaf=tc --diff --out={asldiffdata.nii.gz} \ --mean={asldiffdata_mean.nii.gz}

31 Example pcasl with labeling duration: 1.8 s post-label delay: 1.8 s 2D readout 45.2 ms per slice Assume white paper T1 : 1.6 s ATT : 0 s # Do the analysis using oxford_asl > oxford_asl -i {ASLdata.nii.gz} -o {oxasl} --iaf=tc --casl --tis=3.6 --bolus=1.8 / --slicedt= wp --mc

32 Example pcasl with labeling duration: 1.8 s post-label delay: 1.8 s 2D readout 45.2 ms per slice Assume white paper T1 : 1.6 s ATT : 0 s Do motion correction # Do the analysis using oxford_asl > oxford_asl -i {ASLdata.nii.gz} -o {oxasl} --iaf=tc --casl --tis=3.6 --bolus=1.8 / --slicedt= wp --mc

33 Example Perfusion (arbitrary units) oxasl/native_space/perfusion.nii.gz

34 Example What I have... ASL data (calibration images) What I want... Perfusion in ml/100g/min - = What should I do? Tag-control subtraction. Kinetic model inversion. M0 calculation.

35 M0 Calculation LABEL M0a -M0a T1 decay Well mixed AIF r(t) M(t) 2.M0a * = ΔM(t) = 2 M0a CBF AIF(t) * r(t)

36 Cannot measure M0a directly. indirect via brain tissue magnetization. Calculate M0t. (M0 of tissue ) M0t to M0a. M0 Calculation Steady state magnetization With pre-saturation: ( ) S = M 0 1 e TR T 1 S = M ( 0 1 Ae t T ) 1t With background suppression: No static tissue - need separate calibration images i.e. a control image with BGS off. Account for relative proton densities: M 0a = M 0t λ oxford_asl... -c {calibration_image.nii.gz} --tr={tr} asl_calib --mode longtr... asl_calib --mode satrecov...

37 M0 Calculation Cannot measure M0a directly. indirect via brain tissue magnetization. Calculate M0t. (M0 of tissue ) M0t to M0a. Practicalities Reference tissue? Voxelwise? Voxelwise voxelwise M0a value Calculate M0t M0t M0a Reference tissue Reference tissue mask (CSF or WM) Single global M0a value (coil sensitivity correction) Perfusion (ml/100g/min) = (Perfusion / M0a) * 6000 oxford_asl... -c {calibration_image.nii.gz} --tr=[tr] asl_calib --mode longtr... asl_calib --mode satrecov... fslmaths {perfusion.nii.gz} -div [M0a] -mul 6000 {perfusion_calib.nii.gz}

38 assumption not likely to be strictly tr 2. Labeled blood water is well mixed with tissue before outflowis occurs Because the tissue water pool is much larger than the blood water pool, and water assumption, which are related to the d exchange between blood and tissue is rapid, this typically relatively a good assumption areistypically small. (Zhou J, Wilson D, et al. JCBFM, 21:440, 2001). Under these assumptions CBF in each voxel M0 Calculation 3. The relaxation of the labeled spins are governed by blood T1. While this!"#!!"""! (!" )!!,!"##$ assumption is not likely to be strictly true, the errors introduced this!"#$%!"!!"by!"#$! Analytical solutions - Simple model CBF =(ASL white paper ):![ml/100!! assumption, which are related to the difference in T1 between blood!and tissue,!!,!"##$!!!!,!"##$!"!" (!!! ) are typically relatively small. pcasl pasl QUIPSS II and for QUIPSS II PASL using Under these assumptions CBF in each voxel can be calculated for PCASL using (37): (10): CBF =!"""! (!"!"#$%!"!!"!"#$!!!!!,!"##$!"!" (!!!!"#!!,!"##$ )!!!!!,!"##$ ) CBF =![ml/100!g/min]!"""! (!"!"#$%"&!!"!"#$!!!!"!!"!"!"! )!!,!"##$![ml/100! where λ is the brain/blood partition coefficien α =intensities 0.98 α = 0.85!" averaged signal in the control and!!,!"##$!"""! (!"!"#$%"&!!"!"#$! )! longitudinal relaxation time of blood in secon CBF =![ml/100!g/min]!!!"!!"!" Perfusion (ml/100g/min) = (Perfusion / M0a) * 6000 of asiproton density weighted i where λ is the brain/blood partition coefficientsignal in ml/g,intensity SIcontrol and label are the timeti1 arerespectively, as definedtabove. The factor of 6 voxelwise approach: averaged signal intensities inathe control and and tag images 1, blood is the longitudinal relaxation time ofm blood efficiency, SIPD is thein the phy which is =customary with λ 0.9 ml/g Mseconds, = αsiispdthe/ λlabeling 0a = in 0t / λml/(100g)/min, signal intensity of a proton density weighted image, and τofisparameters the label duration. PLD, TI quan summary for use in CBF and are as defined The factorwith of 6000 the units fromcannot ml/g/s to SIPD is TI a 1proton density above. weighted image long converts TR II modification QUIPSS be reliably co ml/(100g)/min, which is customary in the physiological literature. See Table 3 for a For TR < 5s correct using: TR T1 and for QUIPSS II PASL using (37): S = M (1 e ) 0 quantification. Single TI PASL without the summary of parameters for use in CBF Arterial Spin Labelling : M.A.subtract Chappell To scale the signal intensities of the QUIPSS II modification cannot be reliably converted into CBF. signal intensity of fully relaxed blood spins is yield estimates this value, we recommend To scale the signal intensities of the subtracted ASL-images to of absolute CBF units, the

39 What I have... ASL data (calibration images) What I want... Perfusion in ml/100g/min Example pcasl with labeling duration: 1.8 s post-label delay: 1.8 s 2D readout 45.2 ms per slice Assume T1 (blood) : 1.6 s T1 (tissue) :1.3 s ATT : 1.3 s What should I do? Label-control subtraction. Kinetic model inversion. M0 calculation.

40 Calibration image No background-suppression TR: 4.8 s Example

41 Example Calibration image TR: 4.8 s Calibration mode Voxelwise # Do the analysis using oxford_asl > oxford_asl -i {ASLdata.nii.gz} -o {oxasl} --iaf=tc --casl --tis=3.6 --bolus=1.8 / --slicedt= wp --mc c {calibration_image.nii.gz} --tr=4.8

42 Perfusion (ml/100g/min) Example Correct for edge effects (and distortion) oxasl/native_space/perfusion_calib.nii.gz

43 Example Calibration image TR: 4.8 s Calibration mode Reference region CSF (ventricles) Calibration mask (derived automatically from structural image) # Do the analysis using oxford_asl > oxford_asl -i {ASLdata.nii.gz} -o {oxasl} --iaf=tc --casl --tis=3.6 --bolus=1.8 / --slicedt= wp --mc c {calibration_image.nii.gz} --tr=4.8 / --fslanat=t1.anat

44 Example Perfusion (ml/100g/min) Voxelwise Reference region Ventricular mask (automatically generated) oxasl/native_space/perfusion_calib.nii.gz

45 EXAMPLE What I have... ASL data - multi-ti/pld (calibration images) What I want... Perfusion in ml/100g/min What should I do? Label-control subtraction. Kinetic model inversion. M0 calculation. pcasl with labeling duration: 1.4 s post-label delays: 0.25, 0.5, 0.75,1.0, 1.25, 1.5 s TI: # Label control subtraction for each PLD individually > asl_file --data={asldata.nii.gz} --ntis=6 --iaf=tc --ibf=rpt --diff --split \ --mean={asldiffdata_mean_at_each_pld.nii.gz}

46 Kinetic Model Inversion LABEL T1 decay Well mixed AIF r(t) * M(t) = Parameters: Perfusion - F Bolus arrival time Bolus duration T1 decay (in blood) T1 decay (in tissue) ΔM(t) = F AIF(t) * r(t)

47 Kinetic Model Inversion Parameters: Perfusion - F Arterial Transit Time Bolus duration T1tissue Model white noise Data T1blood Single-TI/PLD Analytic solution Multi-TI/PLD Non-linear fitting (least squares) Bayesian inference (BASIL) Chappell et al., IEEE TSP 57(1), 2009.

48 Kinetic Model Inversion Perfusion Want to know this - variable Bolus/Arterial arrival time Want to correct for this - variable but limited to a sensible range Bolus/Label duration Set by sequence - fixed T1 tissue 1.3 s at 3T might not be that well fixed, pasl? - fixed T1 blood 1.66 at 3T Doesn't T1 vary a bit? - fixed Variability

49 Priors: Perfusion Bolus arrival time Bolus duration T1 Spatial 0.7 s 1.0 s 1.3 s Kinetic Model Inversion Spatial prior: Prior distribution for perfusion in voxel defined over its neighbours σ σ - spatial scale of prior (determined from the data)

50 EXAMPLE What I have... ASL data - multi-ti/pld (calibration images) What I want... Perfusion in ml/100g/min What should I do? Label-control subtraction. Kinetic model inversion. M0 calculation. pcasl with labeling duration: 1.4 s post-label delays: 0.25, 0.5, 0.75,1.0, 1.25, 1.5 s TI: # Label control subtraction for each PLD individually > asl_file --data={asldata.nii.gz} --ntis=6 --iaf=tc --ibf=rpt --diff --split \ --mean={asldiffdata_mean_at_each_pld.nii.gz}

51 Example pcasl with labeling duration: 1.4 s post-label delays: 0.25, 0.5, 0.75,1.0, 1.25, 1.5 s > oxford_asl -i {ASLdata.nii.gz} -o {oxasl} iaf=tc --ibf=rpt --casl \ --tis=1.65,1.9,2.15,2.4,2.65,2.9 --bolus=1.4 --slicedt= \ --fixbolus --artoff --mc \ -c {calibration_image.nii.gz} --tr=4.8

52 Data: pcasl Single-PLD label duration: 1.8 s post-label delay: 1.8 s Assume ATT of 1.3 s Example Ratio Perfusion (ml/100g/min) (multi/single) Single-TI Multi-TI Arrival (seconds) Multi-TI Multi-PLD label duration: 1.4 s PLDs: 0.25, 0.5, 0.75,1.0, 1.25, 1.5 s oxasl/native_space/perfusion_calib.nii.gz oxasl/native_space/arrival.nii.gz

53 Outline Acquisition Keep it simple! Perfusion weighted images. Quantitative perfusion: Kinetics: A short course in tracer kinetics. Calibration: Measuring arterial blood magnetization. Preparing for group analysis. Advanced quantification: Distortion Correction Macro vascular contamination Partial Volume Correction

54 Preparing for Group Analysis Group analysis and quantitative comparisons between individuals requires consistent representation Consistent geometry: Spatial normalization (registration) Transform perfusion map to a common space, e.g. MNI152 Consistent intensity: Quantitive maps - perfusion in ml/100g/min. Intensity normalization to a reference.

55 Registration to standard space ASL Structural linear - 6 DOF Structural Standard linear - 12 DOF non-linear Preparing for Group Analysis oxford_asl... --s {structural_image.nii.gz} See also: asl_reg, flirt, fnirt

56 Example Run fsl_anat on structural image BASIL will then do registration and transformation to: structural space standard space > fsl_anat {T1.nii.gz} > oxford_asl -i {ASLdata.nii.gz} -o {oxasl} --iaf=tc --casl --tis=3.6 --bolus=1.8 / --slicedt= wp --mc c {calibration_image.nii.gz} --tr=4.8 / --fslanat=t1.anat

57 Preparing for Group Analysis Quantitative maps requires estimate of M0a - calibration data. Pros: An absolute scale - can potentially relate to physiology Ought to be able to set consistent thresholds e.g. perfusion < 20 ml/100g/min is ischaemia Cons: Requires calibration information. Global perfusion appears to be quite variable between individuals. Intensity normalization: requires a reference. e.g. a brain structure: thalamus e.g. a global value: mean in GM or WM Pros: No need for calibration. NB still might want coil sensitivity correction. Removes inter subject variability in global perfusion. Cons: Relies on a consistent reference.

58 Preparing for Group Analysis Intensity normalization: Pick a ROI: Manually From atlas From a segmentation Calculate mean within ROI. Scale perfusion maps. oxford_asl... --norm oxford_asl... --report Transform ROI into perfusion space or vice versa? ROI in high-res -> perfusion space Interpolation on ROI mask: sharp boundaries in high-res become soft requiring thresholding - possible bias. Perfusion image -> high-res Interpolation occurs on perfusion values, ROI untouched. Exception is soft segmentations e.g. GM/WM on a structural image. Transform soft segmentations first and THEN threshold to create ROI.

59 GM PVE Preparing for Group Analysis Transform Threshold at 0.7 Threshold at 0.7 Transform Threshold at 0.7 High res GM mask

60 ROI GM / WM(?) partial volume issues Structures Voxelwise Designs Group mean Group differences/paired differences Feat (higher-level analysis) Randomise Group analysis Absolute perfusion: A direct physiological measurement e.g. Asllani et al., JCBFM, 28, A consistent baseline (c.f BOLD) e.g. Wang et. al, MRM, 49, Inter subject and inter session variability e.g Gevers et al., JCBFM, 31, Petersen et al., NeuroImage, 49(1), Arrival time (multi-ti/pld): Potential confound An extra quantitative measurement e.g. Bokkers et al., AJNR, 29(9), MacIntosh et al, AJNR, 33(10), 2012.

61 Outline Acquisition Keep it simple! Perfusion weighted images. Quantitative perfusion: Kinetics: A short course in tracer kinetics. Calibration: Measuring arterial blood magnetization. Preparing for group analysis. Advanced quantification: Distortion Correction Macro vascular contamination Partial Volume Correction

62 Advanced: Distortion Correction EPI readout will include distortion in regions of field inhomogeneity cf BOLD fmri Need to correct for: geometric distortion AND intensity AP encoding PA encoding Corrected Need: field map OR phase encode reversed image oxford_asl... --cblip={asl_calibration_phase_reversed} pedir=[direction] \ --echospacing=[value] oxford_asl... --fmap={fieldmap_image} --fmapmag={fieldmap_magnitude_image} \ --fmapmagbrain={brain_extracted_fmapmag} --pedir=[direction] --echospacing=[value]

63 Example pcasl with labeling duration: 1.8 s post-label delay: 1.8 s 2D readout 45.2 ms per slice Calibration images TR: 4.8 s (1) AP encoding (2) PA encoding echo spacing (dwell time): 0.06 ms # Do the analysis using oxford_asl > oxford_asl -i {ASLdata.nii.gz} -o {oxasl} --iaf=tc --casl --tis=3.6 --bolus=1.8 / --slicedt= wp --mc c {calibration_image.nii.gz} --tr=4.8 / --cblip={calibration_pa.nii.gz} --pedir=y --echospacing=0.06

64 Example Perfusion (ml/100g/min) oxasl/native_space/perfusion_calib.nii.gz

65 Advanced: Macro Vascular Contamination Early TIs may contain label still within larger arteries. perfusion overestimation Use long TI/PLD(s) Use flow suppressing gradients Include in model - multi-ti data provides estimate of arterial blood volume abv and TOF MIP oxford_asl: MV component included by default, use --artoff to turn off Ye et al., MRM 37(2), Chappell et al., MRM 63(5), 2010.

66 Advanced: Macro Vascular Contamination An extended model for ASL: CBF/aBV ΔM(t) = CBF ΔM tiss (t) + abv ΔM IV (t) Bolus arrival time Bolus duration Flat 0.7 s 1.0 s ARD 0.5 s 1.0 s ARD prior: ~N(0,v) v determines the relevance of the prior. v is determined from the data. Restrictive v 0 prior: parameter forced to prior mean v T1 1.3 s 1.6 s Liberal prior: parameter free to be estimated from data

67 EXAMPLE What I have... ASL data - multi-ti/pld (calibration images) What I want... Perfusion in ml/100g/min Arterial blood volume in ml/ml. What should I do? Tag-control subtraction. Kinetic model inversion. M0 calculation. pcasl with labeling duration: 1.4 s post-label delays: 0.25, 0.5, 0.75,1.0, 1.25, 1.5 s TI: > oxford_asl -i {ASLdata.nii.gz} -o {oxasl} iaf=tc --ibf=rpt --casl \ --tis=1.65,1.9,2.15,2.4,2.65,2.9 bolus=1.4 --slicedt= \ --fixbolus --artoff --mc -c {calibration_image.nii.gz} --tr=4.8

68 Example Perfusion ml/100g/min Arterial cerebral blood volume % (ml/ml * 100) middle slice lower slice ~ Circle of Willis oxasl/native_space/perfusion_calib.nii.gz oxasl/native_space/acbv_calib.nii.gz

69 Advanced: Partial Volume Correction Partial voluming of grey and white matter inevitable. Leads to GM perfusion underestimation WM perfusion < GM WM blood arrival > GM Correction PV estimates from segmentation of structural image. Note: partial volume estimates NOT a hard segmentation or probabilities. Make separate GM and WM perfusion estimates in every voxel. An under determined problem.

70 Advanced: Partial Volume Correction Does it matter that much? Resolution of ASL ~ 3 x 3 x 5 mm Cortical thickness ~ 2-4 mm Unlikely to have many pure GM or WM voxels in the cortex Structural resolution Partial Volume Estimate Threshold at 90% ASL resolution Partial Volume Estimate Threshold at 90%

71 Does it matter that much? Resolution of ASL ~ 3 x 3 x 5 mm Cortical thickness ~ 2-4 mm What is this? Advanced: Partial Volume Correction 60 * PVEGM + 10 * PVEWM Estimated perfusion from ASL

72 Advanced: Partial Volume Correction What do we mean when we report GM or WM perfusion? Perfusion ml/100g/ min GM WM Whole brain Threshold on % PVE GM mask threshold at 90% oxford_asl... --report

73 Advanced: Partial Volume Correction Partial volume correction exploiting kinetic data: T1 decay GM WM BAT CBF: GM > WM Bolus arrival: WM > GM

74 Advanced: Partial Volume Correction Multi-component model: ΔM(t) = PV GM ΔM GM (t) + PV WM ΔM WM (t) + PV CSF ΔM CSF (t) + abv ΔM MV (t) Grey matter White matter CSF Macro vasc. ΔM CSF = 0 Spatial priors on CBF for GM and WM

75 Advanced: Partial Volume Correction Chappell et al., MRM 65(4), 2011.

76 EXAMPLE What I have... ASL data - multi-ti/pld (calibration images) What I want... Grey matter perfusion in ml/100g/min What should I do? Tag-control subtraction. Kinetic model inversion. M0 calculation. Partial volume correction pcasl with labeling duration: 1.4 s post-label delays: 0.25, 0.5, 0.75,1.0, 1.25, 1.5 s TI: Segmented structural image, e.g. fsl_anat output > oxford_asl -i {ASLdata.nii.gz} -o {oxasl} iaf=tc --ibf=rpt --casl \ --tis=1.65,1.9,2.15,2.4,2.65,2.9 bolus=1.4 --slicedt= \ --fixbolus --mc --pvcorr --fslanat=t1.anat \ -c {calibration_image.nii.gz} --tr=4.8

77 Perfusion (uncorrected) ml/100g/min EXAMPLE Grey matter perfusion ml/100g/min White matter perfusion ml/100g/min oxasl/native_space/perfusion_calib.nii.gz oxasl/native_space/pvcorr/perfusion_calib_masked.nii.gz oxasl/native_space/pvcorr/perfusion_wm_calib_masked.nii.gz

78 Need to know more FSL: The FMRIB Software Library BASIL: User guide & tutorials for FSL v5.0+ Follow the link for the pre-release and updated user guide/tutorials Oxford Neuroimaging Primers: Introduction to Perfusion Quantification using Arterial Spin Labelling Cover material in this lecture and more. Examples using BASIL (extended from the FSL course)

79 QuBIc, Engineering Science, Oxford Martin Craig Moss Zhao Flora Kennedy McConnell Tom Kirk WIN/FMRIB, Oxford Peter Jezzard Tom Okell Joe Woods Michael Kelly James Meakin Matthew Webster Mark Jenkinson Acknowledgements Brad MacIntosh (Univ. Toronto) Manus Donahue (Vanderbilt) Xavier Golay (UCL, London) Esben Petersen (Utrecht) Marco Castellaro (Padova) Ilaria Boscolo Galazzo (Verona)

80 Task-Based ASL Why use ASL for a functional experiment? A direct measure of perfusion changes - physiological response. (Potentially) fully quantitative - possible to calculate absolute perfusion. Good for low frequency designs. What are the challenges? SNR Temporal sampling - TR and the need for tag and control scans. Time series data will contain both ASL (tag-control difference) and BOLD effects (depends upon the TE used).

81 Task-Based ASL What I have... ASL data during a functional task. T C T C T C T C T C What I want... Activations What should I do? Tag-control subtraction GLM

82 Task-Based ASL Two options in FEAT Do subtraction before GLM (FILM prewhitening OFF) ONLY considers the perfusion contribution, subtraction removes BOLD signal. asl_file --data={asldata.nii.gz} --ntis=1 --iaf=tc --diff --out={diffdata.nii.gz} perfusion_subtract {ASLdata.nii.gz} {diffdata.nii.gz}

83 Task-Based ASL Two options in FEAT Full model Includes perfusion and BOLD contributions EV1 - Tag vs. Control EV2 - BOLD EV3 - Interaction

84 Special: QUASAR QUASAR multi-ti pasl acquisition. Mixture of flow suppression on and off. Saturation recovery control images Analysis model-based - include MV component model-free - numerical deconvolution (c.f. DSC) quasil -i {QUASAR_image} -o {out_dir} quasil -i {QUASAR_image} -o {out_dir} --mfree Petersen et al., MRM 55(2),2006. Chappell et al., MRM e-print, 2013.

Arterial Spin Labelling: Non-invasive measurement of perfusion

Arterial Spin Labelling: Non-invasive measurement of perfusion Arterial Spin Labelling: Non-invasive measurement of perfusion Michael A. Chappell michael.chappell@eng.ox.ac.uk www.ibme.ox.ac.uk/qubic Institute of Biomedical Engineering & Oxford Centre for Functional

More information

Arterial Spin Labeling Read-Out Options

Arterial Spin Labeling Read-Out Options Arterial Spin Labeling Read-Out Options Matthias Günther 1,2,3 1 Fraunhofer MEVIS, Institute for Medical Image Computing 2 Faculty 01 (Physics/Electrical Engineering), University Bremen 3 mediri GmbH,

More information

Challenges for Non-Invasive Brain Perfusion Quantification Using Arterial Spin Labeling

Challenges for Non-Invasive Brain Perfusion Quantification Using Arterial Spin Labeling NRJ Digital - The Neuroradiology Journal 1: 44-50, 2011 www.centauro.it Challenges for Non-Invasive Brain Perfusion Quantification Using Arterial Spin Labeling I. SOUSA 1,2,3, N. SANTOS 1,2,3, J. SANCHES

More information

Arterial Spin Labeling

Arterial Spin Labeling Arterial Spin Labeling Xavier Golay, Ph.D. Department of Brain Repair & Rehabilitation, Institute of Neurology, University College London, UK Introduction Among the various MRI methods measuring cerebral

More information

Model-Free Arterial Spin Labeling Quantification Approach for Perfusion MRI

Model-Free Arterial Spin Labeling Quantification Approach for Perfusion MRI 2005 ISMRM YOUNG INVESTIGATOR RABI AWARD PAPERS Magnetic Resonance in Medicine 55:219 232 (2006) Model-Free Arterial Spin Labeling Quantification Approach for Perfusion MRI Esben Thade Petersen, 1,2 Tchoyoson

More information

What is perfusion, and how do we measure it? Richard B. Buxton

What is perfusion, and how do we measure it? Richard B. Buxton Perfusion Session: Sunday 11 May 2014 What is perfusion, and how do we measure it? Richard B. Buxton rbuxton@ucsd.edu Highlights Perfusion is sometimes used in a loose way to describe different aspects

More information

MR Advance Techniques. Functional MRI. Class IV

MR Advance Techniques. Functional MRI. Class IV MR Advance Techniques Functional MRI Class IV 1 Functional MRI Functional imaging techniques allow MRI to be use to assess the functionality and physiology of the tissues. The contrast of the image depends

More information

Quantitative analysis of arterial spin labeling FMRI data using a general linear model

Quantitative analysis of arterial spin labeling FMRI data using a general linear model Available online at www.sciencedirect.com Magnetic Resonance Imaging 28 (2010) 919 927 Original contributions Quantitative analysis of arterial spin labeling FMRI data using a general linear model Luis

More information

January Signature of Author... Depdtment of Electrical Engineering and Computer Science January 25, 2006

January Signature of Author... Depdtment of Electrical Engineering and Computer Science January 25, 2006 Accuracy of Pulsed Arterial Spin Labeling Magnetic Resonance Imaging in the Human Brain: Tag Width and Timing Effects by Divya Sanam Bolar Submitted to the Department of Electrical Engineering and Computer

More information

Reducing Breath-hold Artifacts on Abdominal MR

Reducing Breath-hold Artifacts on Abdominal MR Reducing Breath-hold Artifacts on Abdominal MR Primary Authors: C. Daniel Johnson, MD James Ellis, MD Mark Baker, MD Joe Veniero, MD, PhD Purpose and Rationale This project aims to reduce the incidence

More information

How to Learn MRI An Illustrated Workbook

How to Learn MRI An Illustrated Workbook How to Learn MRI An Illustrated Workbook Exercise 7: MRCP Teaching Points: What is the effect of slice thickness on pancreatic duct visualization (partial volume averaging)? What is respiratory triggering?

More information

Pulsed-Field Gradient Shimming With VNMR

Pulsed-Field Gradient Shimming With VNMR PFG Shimming With VNMR Page 65 Pulsed-Field Gradient Shimming With VNMR cg fry: created 99.01.27 updated 99.02.01 I. General Discussion Pulsed-field gradients allow analytically accurate, automated adjustments

More information

FieldStrength. Using MotionTrak for motion correction in body imaging. Application tips

FieldStrength. Using MotionTrak for motion correction in body imaging. Application tips FieldStrength Publication for the Philips MRI Community Issue 35 September / October 2008 Using MotionTrak for motion correction in body imaging Application tips This article is part of Field Strength

More information

Simulations of Perfusion Signals of Pulsed Arterial Spin Labeling MRI

Simulations of Perfusion Signals of Pulsed Arterial Spin Labeling MRI Simulations of Perfusion Signals of Pulsed Arterial Spin Labeling MRI Hyug-Gi Kim 1, 2, Geon-Ho Jahng 1, Chang-Hyun Oh 2 Purpose : A pulsed arterial spin labeling (PASL) signal usually depends on several

More information

Challenges in Measuring CSF Flow with MRI

Challenges in Measuring CSF Flow with MRI Challenges in Measuring CSF Flow with MRI Rafeeque A. Bhadelia, MD HARVARD MEDICAL SCHOOL Background MR imaging of CSF flow is difficult to use in clinical practice This is because: Qualitative visual

More information

How to Learn MRI An Illustrated Workbook

How to Learn MRI An Illustrated Workbook How to Learn MRI An Illustrated Workbook Exercise : Scanning the Abdomen Teaching Points: How to eliminate wrap around artifact of the arms. How to reduce respiration motion artifact. What is axial in-phase

More information

intended velocity ( u k arm movements

intended velocity ( u k arm movements Fig. A Complete Brain-Machine Interface B Human Subjects Closed-Loop Simulator ensemble action potentials (n k ) ensemble action potentials (n k ) primary motor cortex simulated primary motor cortex neuroprosthetic

More information

Climate Change Scenarios for the Agricultural and Hydrological Impact Studies

Climate Change Scenarios for the Agricultural and Hydrological Impact Studies Climate Change Scenarios for the Agricultural and Hydrological Impact Studies Martin Dubrovský (WP 3, 5, 6) hotel Mendi, Halkidiki, Greece ***** 10-12. June 2009 scheme of cc impacts study GCM output obs.wea.series

More information

GCMSD-Headspace Analysis SOP

GCMSD-Headspace Analysis SOP Before you start GCMSD-Headspace Analysis SOP Method and Sequences names are restricted to 50 characters (MSD program will crash otherwise) The GC oven and Injection Ports need to be cooled to 50 oc to

More information

Climate Change Scenarios for the Agricultural and Hydrological Impact Studies

Climate Change Scenarios for the Agricultural and Hydrological Impact Studies Climate Change Scenarios for the Agricultural and Hydrological Impact Studies Martin Dubrovský (WP 3, 5, 6) Masarykova kolej, Praha ***** 25-27 November 2009 scheme of cc impacts study GCM output obs.wea.series

More information

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah MEDICAL EQUIPMENT IV - 2013 MECHANICAL VENTILATORS Prof. Yasser Mostafa Kadah Mechanical Ventilator A ventilator is a machine, a system of related elements designed to alter, transmit, and direct energy

More information

Diffusion MRI: Basic Principles and Clinical Applications

Diffusion MRI: Basic Principles and Clinical Applications Diffusion MRI: Basic Principles and Clinical Applications Computerunterstützte Klinische Medizin Medizinische Fakultät Mannheim Universität Heidelberg Theodor-Kutzer-Ufer 1-3 D-68167 Mannheim www.ma.uni-heidelberg.de/inst/cbtm/ckm

More information

Brent Sleep, Magdalena Krol, University of Toronto Kevin Mumford, Queen s University Richard Johnson, Oregon Health and Science University

Brent Sleep, Magdalena Krol, University of Toronto Kevin Mumford, Queen s University Richard Johnson, Oregon Health and Science University Brent Sleep, Magdalena Krol, University of Toronto Kevin Mumford, Queen s University Richard Johnson, Oregon Health and Science University Electrical Resistance Heating (ERH) Power Control System Vapour

More information

Energy Output. Outline. Characterizing Wind Variability. Characterizing Wind Variability 3/7/2015. for Wind Power Management

Energy Output. Outline. Characterizing Wind Variability. Characterizing Wind Variability 3/7/2015. for Wind Power Management Energy Output for Wind Power Management Spring 215 Variability in wind Distribution plotting Mean power of the wind Betz' law Power density Power curves The power coefficient Calculator guide The power

More information

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Lab 1c Isentropic Blow-down Process and Discharge Coefficient 058:080 Experimental Engineering Lab 1c Isentropic Blow-down Process and Discharge Coefficient OBJECTIVES - To study the transient discharge of a rigid pressurized tank; To determine the discharge coefficients

More information

Validation of SEC/GPC Software

Validation of SEC/GPC Software Validation of SEC/GPC Software M. Gray, P. KiIz*, G. Reinhold* PSS-USA, 13531Cedar Creek Lane, Silver Spring, MD 20904 *PSS Polymer Standards Service GmbH, POB 3368, D-55023 Mainz Poster presented at the

More information

Measuring Lung Water: Ex Vivo Validation of Multi-image Gradient Echo MRI

Measuring Lung Water: Ex Vivo Validation of Multi-image Gradient Echo MRI JOURNAL OF MAGNETIC RESONANCE IMAGING 34:220 224 (2011) Technical Note Measuring Lung Water: Ex Vivo Validation of Multi-image Gradient Echo MRI Sebastiaan Holverda, PhD, 1 * Rebecca J. Theilmann, PhD,

More information

Carrier Gases in Capillary GC

Carrier Gases in Capillary GC Carrier Gases in Capillary GC LC Columns and Consumables Mark Sinnott Application Engineer January 15, 2009 CARRIER GAS Mobile Phase Carries the solutes down the column Selection and velocity influences

More information

I Physical Principles of Gas Exchange

I Physical Principles of Gas Exchange Respiratory Gases Exchange Dr Badri Paudel, M.D. 2 I Physical Principles of Gas Exchange 3 Partial pressure The pressure exerted by each type of gas in a mixture Diffusion of gases through liquids Concentration

More information

INTRODUCTION TO BI-VENT (APRV) INTRODUCTION TO BI-VENT (APRV) PROGRAM OBJECTIVES

INTRODUCTION TO BI-VENT (APRV) INTRODUCTION TO BI-VENT (APRV) PROGRAM OBJECTIVES INTRODUCTION TO BI-VENT (APRV) INTRODUCTION TO BI-VENT (APRV) PROGRAM OBJECTIVES PROVIDE THE DEFINITION FOR BI-VENT EXPLAIN THE BENEFITS OF BI-VENT EXPLAIN SET PARAMETERS IDENTIFY RECRUITMENT IN APRV USING

More information

Monitor Unit Verification for Small Fields

Monitor Unit Verification for Small Fields Monitor Unit Verification for Small Fields Patrick Higgins, Ph.D University of Minnesota Department of Radiation Oncology October 10, 2013 The Issues: How do we verify the monitor units calculated by the

More information

Relative Dosimetry. Photons

Relative Dosimetry. Photons Relative Dosimetry Photons What you need to measure! Required Data (Photon) Central Axis Percent Depth Dose Tissue Maximum Ratio Scatter Maximum Ratio Output Factors S c & S cp! S p Beam profiles Wedge

More information

DERIVATION OF A SIGNAL TIMING SCHEME FOR AN EXTERNALLY SIGNALIZED ROUNDABOUT

DERIVATION OF A SIGNAL TIMING SCHEME FOR AN EXTERNALLY SIGNALIZED ROUNDABOUT DERIVATION OF A SIGNAL TIMING SCHEME FOR AN EXTERNALLY SIGNALIZED ROUNDABOUT Paper Presented at the Annual Sessions of the Institute of Engineers, Sri Lanka Dr. Amal S. Kumarage, Senior Lecturer Dr. J.M.S.J.

More information

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Available online at  ScienceDirect. Procedia Engineering 112 (2015 ) Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 112 (2015 ) 540 545 7th Asia-Pacific Congress on Sports Technology, APCST 2015 Movement variability of professional pool billiards

More information

Welcome Pre-conference Workshop Walk21, Vienna, 20 October 2015

Welcome Pre-conference Workshop Walk21, Vienna, 20 October 2015 Welcome Pre-conference Workshop Walk21, Vienna, 20 October 2015 Measuring Walking (part VII): International Walking Data Standard and its benefit Daniel Sauter, Urban Mobility Research, Zurich, Switzerland

More information

Application Block Library Fan Control Optimization

Application Block Library Fan Control Optimization Application Block Library Fan Control Optimization About This Document This document gives general description and guidelines for wide range fan operation optimisation. Optimisation of the fan operation

More information

Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers

Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers Journal of Physics: Conference Series PAPER OPEN ACCESS Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers Related content - The versatile use

More information

Table of Contents. By Adam Hollingworth

Table of Contents. By Adam Hollingworth By Adam Hollingworth Table of Contents Oxygen Cascade... 2 Diffusion... 2 Laws of Diffusion... 2 Diffusion & Perfusion Limitations... 3 Oxygen Uptake Along Pulmon Capillary... 4 Measurement of Diffusing

More information

cudimot: A CUDA toolbox for modelling the brain tissue microstructure from diffusion-mri

cudimot: A CUDA toolbox for modelling the brain tissue microstructure from diffusion-mri cudimot: A CUDA toolbox for modelling the brain tissue microstructure from diffusion-mri Moisés Hernández Fernández Istvan Reguly, Mike Giles, Stephen Smith and Stamatios N. Sotiropoulos GPU Technology

More information

Quantification of MRI Sensitivity for Mono-disperse Microbubbles to Measure Subatmospheric Fluid Pressure Changes.

Quantification of MRI Sensitivity for Mono-disperse Microbubbles to Measure Subatmospheric Fluid Pressure Changes. The Open-Access Journal for the Basic Principles of Diffusion Theory, Experiment and Application Quantification of MI Sensitivity for Mono-disperse Microbubbles to Measure Subatmospheric Fluid Pressure

More information

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters. New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters. System M Spectrum Medicals total commitment to continuous product improvement is demonstrated

More information

Universal Style Transfer via Feature Transforms

Universal Style Transfer via Feature Transforms Universal Style Transfer via Feature Transforms Yijun Li, Chen Fang, Jimei Yang, Zhaowen Wang, Xin Lu, Ming-Hsuan Yang UC Merced, Adobe Research, NVIDIA Research Presented: Dong Wang (Refer to slides by

More information

Title: Modeling Crossing Behavior of Drivers and Pedestrians at Uncontrolled Intersections and Mid-block Crossings

Title: Modeling Crossing Behavior of Drivers and Pedestrians at Uncontrolled Intersections and Mid-block Crossings Title: Modeling Crossing Behavior of Drivers and Pedestrians at Uncontrolled Intersections and Mid-block Crossings Objectives The goal of this study is to advance the state of the art in understanding

More information

BIOPAC Blood Flow Monitor

BIOPAC Blood Flow Monitor BIOPAC Blood Flow Monitor Technique - Laser Doppler Flowmetry (LDF) The LDF100C is a laser Doppler blood perfusion monitor used to measure real-time micro-vascular red blood cell perfusion in tissue. LDF100C

More information

Sensoric 4-20 ma Transmitter Board Operation Manual

Sensoric 4-20 ma Transmitter Board Operation Manual Sensoric 4-20 ma Transmitter Board Operation Manual 1 Content Features Operation Manual Technical Data Mechanical Dimensions Remarks & Contact information 2 Features Soldered sensor cell (non replaceable)

More information

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance Introduction Expired Gas Analysis or indirect calorimetry, can be used to measure ventilation and the fractions of oxygen and carbon dioxide in expired air. From these measurements, the body's oxygen consumption

More information

EXPERIMENTAL RESULTS OF GUIDED WAVE TRAVEL TIME TOMOGRAPHY

EXPERIMENTAL RESULTS OF GUIDED WAVE TRAVEL TIME TOMOGRAPHY 18 th World Conference on Non destructive Testing, 16-20 April 2012, Durban, South Africa EXPERIMENTAL RESULTS OF GUIDED WAVE TRAVEL TIME TOMOGRAPHY Arno VOLKER 1 and Hendrik VOS 1 TNO, Stieltjesweg 1,

More information

Sontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004

Sontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004 Sontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004 INTRODUCTION Sontek/YSI has introduced new firmware and software for their RiverSurveyor product line. Firmware changes

More information

Basics of Proton Therapy. Proton Treatment Planning and Beam Optimization

Basics of Proton Therapy. Proton Treatment Planning and Beam Optimization Basics of Proton Therapy Proton Treatment Planning and Beam Optimization SAM Educational Session, WE D BRB 2 Mark Pankuch, PhD Northwestern Medicine Chicago Proton Center Today s objectives Review the

More information

Pulmonary Circulation Linda Costanzo Ph.D.

Pulmonary Circulation Linda Costanzo Ph.D. Pulmonary Circulation Linda Costanzo Ph.D. OBJECTIVES: After studying this lecture, the student should understand: 1. The differences between pressures in the pulmonary and systemic circulations. 2. How

More information

Lung Volumes and Capacities

Lung Volumes and Capacities Lung Volumes and Capacities Normally the volume of air entering the lungs during a single inspiration is approximately equal to the volume leaving on the subsequent expiration and is called the tidal volume.

More information

Domain Decomposition Method for 3-Dimensional Simulation of the Piston Cylinder Section of a Hermetic Reciprocating Compressor

Domain Decomposition Method for 3-Dimensional Simulation of the Piston Cylinder Section of a Hermetic Reciprocating Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2006 Domain Decomposition Method for 3-Dimensional Simulation of the Piston Cylinder Section

More information

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006 ZIN Technologies PHi Engineering Support PHi-RPT-0002 CFD Analysis of Large Bubble Mixing Proprietary ZIN Technologies, Inc. For nearly five decades, ZIN Technologies has provided integrated products and

More information

Chapter Capacity and LOS Analysis of a Signalized I/S Overview Methodology Scope Limitation

Chapter Capacity and LOS Analysis of a Signalized I/S Overview Methodology Scope Limitation Chapter 37 Capacity and LOS Analysis of a Signalized I/S 37.1 Overview The Highway Capacity Manual defines the capacity as the maximum howdy rate at which persons or vehicle can be reasonably expected

More information

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

A4 Operation Manual. Fig.1-1 Controller Socket Diagram A4 Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and

More information

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT Responding to your needs One of the best selling resuscitators... Smiths Medical is bringing you the next generation of emergency ventilators.

More information

Cricket umpire assistance and ball tracking system using a single smartphone camera

Cricket umpire assistance and ball tracking system using a single smartphone camera 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Cricket umpire assistance and ball tracking system using a single smartphone camera Udit Arora

More information

Modeling of Estimated Respiratory Waveform

Modeling of Estimated Respiratory Waveform Modeling of Estimated Respiratory Waveform ALEKSEI E. ZHDANOV, LEONID G. DOROSINSKY Institute of Radioelectronics and Information Technology - RTF Ural Federal University named after the first President

More information

Rural Highway Overtaking Lanes

Rural Highway Overtaking Lanes Rural Highway Overtaking Lanes Kah Wai Ng School of Civil and Resource Engineering, University of Western Australia Song Wang School of Mathematics and Statistics, University of Western Australia Doina

More information

DOWNLOAD OR READ : VENTILATION BLOOD FLOW AND DIFFUSION PDF EBOOK EPUB MOBI

DOWNLOAD OR READ : VENTILATION BLOOD FLOW AND DIFFUSION PDF EBOOK EPUB MOBI DOWNLOAD OR READ : VENTILATION BLOOD FLOW AND DIFFUSION PDF EBOOK EPUB MOBI Page 1 Page 2 ventilation blood flow and diffusion ventilation blood flow and pdf ventilation blood flow and diffusion Title:

More information

TG-119 IMRT Commissioning Tests Instructions for Planning, Measurement, and Analysis Version 10/21/2009

TG-119 IMRT Commissioning Tests Instructions for Planning, Measurement, and Analysis Version 10/21/2009 TG-119 IMRT Commissioning Tests Instructions for Planning, Measurement, and Analysis Version 10/21/2009 DISCLAIMER: This publication and associated spreadsheets and digital files are based on sources and

More information

SIDRA INTERSECTION 6.1 UPDATE HISTORY

SIDRA INTERSECTION 6.1 UPDATE HISTORY Akcelik & Associates Pty Ltd PO Box 1075G, Greythorn, Vic 3104 AUSTRALIA ABN 79 088 889 687 For all technical support, sales support and general enquiries: support.sidrasolutions.com SIDRA INTERSECTION

More information

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay Summary This assay measures Human Granulocyte Colony Stimulating Factor (G-CSF) in a 96-well

More information

A4s Operation Manual

A4s Operation Manual A4s Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and

More information

Appendix B: Forecasting and Traffic Operations Analysis Framework Document

Appendix B: Forecasting and Traffic Operations Analysis Framework Document Existing Conditions Report - Appendix Appendix B: Forecasting and Traffic Operations Analysis Framework Document This document defines the methodology and assumptions that will be used in the traffic forecasting

More information

Building an NFL performance metric

Building an NFL performance metric Building an NFL performance metric Seonghyun Paik (spaik1@stanford.edu) December 16, 2016 I. Introduction In current pro sports, many statistical methods are applied to evaluate player s performance and

More information

YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD.

YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD. YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD. Contents 1 Notice 1.1 Work environment 1.2 Notice of installation 1.3 Notice of safety 2 Installation and Adjustment 2.1 Controll box 2.2 Speed controller

More information

Core Concept. PowerPoint Lectures Physical Science, 8e. Chapter 5 Wave Motions and Sound. New Symbols for this Chapter 2/20/2011

Core Concept. PowerPoint Lectures Physical Science, 8e. Chapter 5 Wave Motions and Sound. New Symbols for this Chapter 2/20/2011 PowerPoint Lectures Physical Science, 8e Chapter 5 Wave Motions and Sound New Symbols for this Chapter T-Period f-frequency v-wave speed λ-wavelength A-Amplitude Sound is transmitted as increased and decreased

More information

Roller AC Servo System

Roller AC Servo System Safely Instruction Roller AC Servo System HMI-15 User Manual Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller

More information

Shimming with VnmrJ 3.1 Software for Peak NMR Performance

Shimming with VnmrJ 3.1 Software for Peak NMR Performance Shimming with VnmrJ 3.1 Software for Peak NMR Performance Application Note Author Ron Crouch Agilent Technologies 13000 Weston Parkway Cary, NC 27513 USA Shimming is the term used to describe the process

More information

Solutions for transcutaneous monitoring

Solutions for transcutaneous monitoring Solutions for transcutaneous monitoring About Radiometer Radiometer is a leading provider of technologically advanced acute care solutions that simplify and automate all phases of acute care testing. By

More information

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary ADH 1/7/014 LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary This experiment will introduce you to the kinetic properties of low-pressure gases. You will make observations on the

More information

Reprocessed QuikSCAT (V04) Wind Vectors with Ku-2011 Geophysical Model Function

Reprocessed QuikSCAT (V04) Wind Vectors with Ku-2011 Geophysical Model Function Reprocessed QuikSCAT (V04) Wind Vectors with Ku-2011 Geophysical Model Function Lucrezia Ricciardulli and Frank Wentz Introduction In April 2011, we reprocessed the QuikSCAT ocean wind vectors using a

More information

Shearwater GeoServices. Increasing survey productivity and enhancing data quality February 2017 Steve Hepburn Acquisition Geophysicist

Shearwater GeoServices. Increasing survey productivity and enhancing data quality February 2017 Steve Hepburn Acquisition Geophysicist Shearwater GeoServices Increasing survey productivity and enhancing data quality February 2017 Steve Hepburn Acquisition Geophysicist Shearwater GeoServices - Full Geophysical Service Company Marine Processing

More information

Chapter 10 Gases. Characteristics of Gases. Pressure. The Gas Laws. The Ideal-Gas Equation. Applications of the Ideal-Gas Equation

Chapter 10 Gases. Characteristics of Gases. Pressure. The Gas Laws. The Ideal-Gas Equation. Applications of the Ideal-Gas Equation Characteristics of Gases Chapter 10 Gases Pressure The Gas Laws The Ideal-Gas Equation Applications of the Ideal-Gas Equation Gas mixtures and partial pressures Kinetic-Molecular Theory Real Gases: Deviations

More information

S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE

S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE 1. INTRODUCTION The s-curve function allows the user to define a smooth response yet still maintain a high acceleration. In many applications

More information

BLOOD PRESSURE SENSOR BT17i USER S GUIDE

BLOOD PRESSURE SENSOR BT17i USER S GUIDE BLOOD PRESSURE SENSOR BT17i USER S GUIDE CENTRE FOR MICROCOMPUTER APPLICATIONS http://www.cma-science.nl Short description The Blood Pressure sensor BT17i allows measuring arterial blood pressure. The

More information

Introduction to Roundabout Analysis Using ARCADY

Introduction to Roundabout Analysis Using ARCADY Introduction to Roundabout Analysis Using ARCADY Toronto SimCap User Group Technical Event and ITE Toronto Section Social Event July 22, 2014 Phil Weber, P.Eng. GHD Inc. (The Home of Ourston Roundabout

More information

Section 4.2. Travelling Waves

Section 4.2. Travelling Waves Section 4.2 Travelling Waves Wave Motion A wave is the motion of a disturbance Mechanical waves require Some source of disturbance A medium that can be disturbed Some physical connection between or mechanism

More information

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President Lowell Instruments Application Note #TCMA Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President 1 Introduction The TCM-1 Tilt Current Meter (TCM)

More information

Flaw Detection Capabilities with Eddy Current Array Technology

Flaw Detection Capabilities with Eddy Current Array Technology Flaw Detection Capabilities with Eddy Current Array Technology 2018 ASNT Annual Conference Jesse Herrin 1 Agenda Common NDT Techniques for Surface Flaws Eddy Current Array (ECA) Testing and Benefits Scan

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

Deuterium more than just for locking: Part II. H Topshim. Donna Baldisseri Boston Massachusetts Pre-ENC Workshops 2014, March 22

Deuterium more than just for locking: Part II. H Topshim. Donna Baldisseri Boston Massachusetts Pre-ENC Workshops 2014, March 22 Deuterium more than just for locking: Part II 2 H Topshim Donna Baldisseri Boston Massachusetts Pre-ENC Workshops 2014, March 22 Topshim Fully automated Reliable Easy to use Customizable Good, rapid results

More information

Application Note AN-107

Application Note AN-107 SPEC Sensor TM Characterization & Calibration Considerations Scope This document is provided to describe the considerations needed to characterize, calibrate, verify and validate the measurement performance

More information

The Powerful Sealing Calculation

The Powerful Sealing Calculation KLINGER expert 6.0 The Powerful Sealing Calculation The KLINGER expert 6.0 gasket design program is a versatile software to assist users in the selection of non-metallic gasket materials. www.klinger.co.at

More information

EVALUATION OF ENVISAT ASAR WAVE MODE RETRIEVAL ALGORITHMS FOR SEA-STATE FORECASTING AND WAVE CLIMATE ASSESSMENT

EVALUATION OF ENVISAT ASAR WAVE MODE RETRIEVAL ALGORITHMS FOR SEA-STATE FORECASTING AND WAVE CLIMATE ASSESSMENT EVALUATION OF ENVISAT ASAR WAVE MODE RETRIEVAL ALGORITHMS FOR SEA-STATE FORECASTING AND WAVE CLIMATE ASSESSMENT F.J. Melger ARGOSS, P.O. Box 61, 8335 ZH Vollenhove, the Netherlands, Email: info@argoss.nl

More information

MNI (x,y,z) T value. Dorsal Attention Network (DAN) Pre vs. NC

MNI (x,y,z) T value. Dorsal Attention Network (DAN) Pre vs. NC Supplementary Table 1. Increased/decreased functional connectivity of resting state networks in patients and controls. Anatomical Locations Hemisphere BA Cluster voxels MNI (x,y,z) T value Default Mode

More information

Section Two Diffusion of gases

Section Two Diffusion of gases Section Two Diffusion of gases Lecture 5: Partial pressure and the composition of gasses in air. Factors affecting diffusion of gases. Ventilation perfusion ratio effect on alveolar gas concentration.

More information

Windcube FCR measurements

Windcube FCR measurements Windcube FCR measurements Principles, performance and recommendations for use of the Flow Complexity Recognition (FCR) algorithm for the Windcube ground-based Lidar Summary: As with any remote sensor,

More information

INSTITUTE AND FACULTY OF ACTUARIES. Curriculum 2019 AUDIT TRAIL

INSTITUTE AND FACULTY OF ACTUARIES. Curriculum 2019 AUDIT TRAIL INSTITUTE AND FACULTY OF ACTUARIES Curriculum 2019 AUDIT TRAIL Subject CP2 Actuarial Modelling Paper One Institute and Faculty of Actuaries Triathlon model Objective Each year on the Island of IFoA a Minister

More information

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math! Physiology of Oxygen Transport PICU Resident Self-Study Tutorial I was told that there would be no math! INTRODUCTION Christopher Carroll, MD Although cells rely on oxygen for aerobic metabolism and viability,

More information

Golf Ball Impact: Material Characterization and Transient Simulation

Golf Ball Impact: Material Characterization and Transient Simulation 12 th International LS-DYNA Users Conference Blast/Impact(1) Golf Ball Impact: Material Characterization and Transient Simulation Xiaohu Liu, David Quinn and Jorgen Bergström Veryst Engineering, LLC 47A

More information

A-LEVEL PHYSICS A. PHA5B Medical Physics Mark scheme June Version: 1.0 Final

A-LEVEL PHYSICS A. PHA5B Medical Physics Mark scheme June Version: 1.0 Final A-LEVEL PHYSICS A PHA5B Medical Physics Mark scheme 450 June 04 Version:.0 Final Mark schemes are prepared by the Lead Assessment Writer and considered, together with the relevant questions, by a panel

More information

Blood Parameter Monitoring System 550

Blood Parameter Monitoring System 550 Technical Compendium CDI Blood Parameter Monitoring System 550 An overview of the CDI System 550 and its industry leading technology. CDI System 550 Measures or Calculates 12 Critical Blood Parameters

More information

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310 www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Varian 310 310 LC/MS Manual System INCLUDES: 310-MS LC/MS triple quadrople

More information

THE WAVE CLIMATE IN THE BELGIAN COASTAL ZONE

THE WAVE CLIMATE IN THE BELGIAN COASTAL ZONE THE WAVE CLIMATE IN THE BELGIAN COASTAL ZONE Toon Verwaest, Flanders Hydraulics Research, toon.verwaest@mow.vlaanderen.be Sarah Doorme, IMDC, sarah.doorme@imdc.be Kristof Verelst, Flanders Hydraulics Research,

More information

LEAP CO 2 Laboratory CO 2 mixtures test facility

LEAP CO 2 Laboratory CO 2 mixtures test facility LEAP CO 2 Laboratory CO 2 mixtures test facility THE PROJECT AIM CO 2 flows made available by several capture techniques are contaminated with impurities and this affects the design and operations of the

More information

HRLA High-Resolution Laterolog Array Tool. Improving the accuracy of Rt

HRLA High-Resolution Laterolog Array Tool. Improving the accuracy of Rt HRLA High-Resolution Laterolog Array Tool Improving the accuracy of Rt Applications Resistivity determination in conductive mud systems Thin-bed evaluation Invasion characterization for permeability indication

More information

Proceedings of Meetings on Acoustics

Proceedings of Meetings on Acoustics Proceedings of Meetings on Acoustics Volume 9, 2010 http://acousticalsociety.org/ 159th Meeting Acoustical Society of America/NOISE-CON 2010 Baltimore, Maryland 19-23 April 2010 Session 1pBB: Biomedical

More information

WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES

WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES Christophe ALEXANDROPOULOS and Muriel LACOMBE Météo-France, Direction des Systèmes d Observation, BP 202-78195 Trappes France christophe.alexandropoulos@meteo.fr

More information