SP-400-M1/SP-403K-M1 INSTRUCTIONS

Size: px
Start display at page:

Download "SP-400-M1/SP-403K-M1 INSTRUCTIONS"

Transcription

1 SP-400-M1/SP-403K-M1 INSTRUCTIONS PACK YOUR OWN CAPILLARIES FOR HPLC AND LC-MS revision TABLE OF CONTENT SP-400-M1 AND SP-403-M1 KIT COMPONENTS PAGE 2 COMPONENT ASSEMBLY DIAGRAM PAGE 3 COMPONENT PHOTO LIBRARY PAGE 4 GENERAL INFORMATION, SAFETY & CARE PAGE 5 ASSEMBLY & CONNECT TO PRESSURE SOURCE PAGE 6 COLUMN ASSEMBLY PAGE 8 SLURRY PREPARATION PAGE 10 ATTACHMENT OF COLUMN PAGE 10 PACKING THE COLUMN & LC-MS TIPS PAGE 12 COLUMN REMOVAL PAGE 13 PARTS AND ACCESSORIES LISTING PAGE SP-400 CUTAWAY

2 Nanobaume TM is a Trademark of Western Fluids Engineering & Mfg, LLC Inconel is a Registered Trademark of Inco Alloys International, Inc. Kel-F is a Registered Trademark of the 3M Company PEEKsil TM is a Trademark of SGE International Pty. Ltd. PEEK TM polymer is a Trademark of Victrex PLC PolySULFOETHYL A TM, PolyCAT A TM, PolyHYDROXYETHYL A TM, and PolyPROPYL A TM are trademarks of PolyLC Inc. Teflon and Tefzel are Registered Trademarks of E.I. du Pont de Nemours and Company SP-400-M1/SP-403K-M1 INSTRUCTIONS Nanobaume Kit Components Use the SP-400-M1 and SP-403K -M1 Nanobaume TM kits to pack micro and capillary columns of various lengths and of outer diameters. The compact design seals effectively at high pressure, up to 9000 psi *. The following items are included in the SP-400-M1: Western Fluids Engineering and Manufacturing, LLC PART # IMAGE SP-1333 G SP-014 L SP-01 5 M SP I SP-085 J SP E SP A SP B SP C DESCRIPTION FERRULE, PEEK, FOR 1/32 OD COLUMNS (QTY 5) STAINLESS STEEL NUT, (for SP-015 only) FERRULE, KEL-F, FOR 360 MICRON OD (QTY 5) O-RING, FFKM Perfluoroesalstomer PTFE STIR BAR, 5MM X 2MM PRESSURE CONNECTION MALE FOR 1/16" TUBERESS CAP LOCK, SS316 CAP SEAL, SS316 PACKER BODY, SS316 SP-400-M1 Nanobaume TM Assembly VL-002 SP-134 SP-130 SP-125 D H F K GLASS VIAL, 2ML, 12X32MM, BOROSILICATE FERRULE FOR 1/16" COLUMN CONNECT SS NUT FOR 1/16" COLUMN CONNECT VIAL INSERT FOR 2ML VL-002 VIAL -M1 -M1 : PART # IMAGE DESCRIPTION SP-087 SP-046 SP-050 SP-055 SP-058 VL-002X CE-005-M1 SP-110 N O P Q R D T S PRESSURE GAUGE, PSI, SS316 TUBING, ID X 1/16 OD X 10CM, SS316 (QTY 2) SHUTOFF VALVE, WITH BOTTOM VENT TUBING, ID X 1/16 OD X 5 FEET, SS316 PRESSURE GAUGE GAUGE TEE FOR 1/16 OD TUBING PK/10, includes CE-003, CE-006, plus other items, see main brochure for details TANK ADAPTER, 1/4" MALE NPT TO 1/16" TUBE SP-403K-M1 nobaume TM Startup Kit 2 * Packing limit of the pressure vessel is 9000 psig with liquid media. Use of fused silica capillary and adapters will reduce the working pressure of packer to 6000 psig.

3 COMPONENTS AND ASSEMBLY SP-050 Valve with bottom vent Cap Lock SP SP-046 SP-055 Direction of Pressure Flow SP-087 Pressure Gauge with SP-058 Gauge Tee CE-003 End Fitting retains silica bed while packing Pressure Vent (Bypass) Pressure Source Tank or Pump Nut SP-130 Ferrule SP-133 or SP-134 Cap Seal SP Stir Bar SP-085 Glass Vial VL-002 VIAL INSERT SP-125 not shown O-Ring SP-130 NUT with SP-133 or SP-134 Complete Column with CE-003 End Fittings SP Packer Body SP NOW FEMALE THREAD SP-400 Packing Unit SP-400 -M1 PARTS ASSEMBLY SP-116 SP-403K-M1 PARTS ASSEMBLY DIAGRAM 3

4 COMPONENTS OF THE SP-400-M1 AND SP-403K-M1 01 A CAP LOCK, SP D VIAL VL-002 G FERRULE FOR TUBE 1/32" SP-133 J PTFE STIR BAR SP-085 B CAP SEAL SP E PRESSURE CONNECTION SP-116 H FERRULE FOR TUBE 1/16" SP-134 K VIAL INSERT SP-125 C BODY, SP F COLUMN CONNECION SP-130 Items A-M above are included in our base unit, the SP-400-M1 Nanobaume. The SP-403K-M1 Startup Kit includes all the components of the SP-400-M1, as well as the additional packing accessories illustrated below (items N-T). I O-RING SP L M COLUMN NUT SP-014 FERRULE, 360UM TUBE SP-015 N PRESSURE GAUGE SP-087 T O P Q SS TUBE 1/16"x.020" x10cm SP-046 VALVE PRESSURE RELIEF SP-050 SS TUBE 1/16"x.020"x 5FT SP-055 CE-005-M1 COLUMN ADAPTER KIT SEE MAIN BROCHURE FOR COMPONENTS CONTAINED. 1/32" OD COLUMN END FITTINGS CE-003,2 EA 1/16" OD COLUMN END FITTINGS CE-006, 2 EA 1/32" SS SCREEN.5UM, 2 EA 1/16" SS SCREEN.5UM, 2 EA FUSED SILICA 360UM OD X 150UM ID,.5MTR PEEKSIL, 1/32", 100UM ID X 100MM LONG PK/2 PEEKSIL,1/16",150UM IDX 150MM, NOT SHOWN 2 EA FERRULE, WITH SS RING 1/32" PEEK, 2 EA FERRULE, WITH SS RING 1/16" PEEK, 2 EA MALE NUT, SS 10-32, 1 EA ADAPTER SLEEVES SET FOR F.S., 1 SET R TEE, PRESSURE GAUGE SP-058 S REGULATOR ADAPTER SP-110 4

5 1. GENERAL INFORMATION 1.1 The Nanobaume is a compact stainless steel unit designed to pack capillary columns with a silica bed at high pressure. Its unique sealing design permits rapid assembly, facilitating quick packing changeover. Simple hand tightening the pressure vessel will seal up to 9000 psig with liquid media, 3000 psig with gas. No tools are required to operate the packing unit, although a set of adjustable wrenches is useful for initial setup and column assembly. SP-400-M1 and SP-403K-M1 kits include connections for 360um, 1/32" OD, 1/16" outside diameter (OD) columns, but the NANOBaume will accept small OD column diameters using the TS-015 sleeve kit. LC-MS spray tips may also be packed. Component materials include Kel-F, PEEK, 316SS, 304SS, Borosilicate glass, ETFE, and FFKM perfluoroelastomer. The vial insert (SP-125) supplied with the SP-400-M1 will accept 2 ml (12x32mm) glass vials. Other inserts are available, (please inquire) 2 PRODUCT SAFETY AND CARE 2.1 The NANOBaume is not for use under Supercritical Fluid conditions. Do not exceed the published pressure limits (9000psig liquid/3000 psig gas). Always operate with a safety shield in place. When packing with liquid media, first flood the Nanobaume and empty column with solvent. If using the TS- 015 sleeve adapters or SP-015, SP-014 Ferrule/Nut for the capillary columns, then pressure limit is reduced to 6000psig. CAP LOCK, SP O RING, SP CAP SEAL, SP BODY, SP FIG 1 FIG 2 FIG 3 FIG Hand tighten the cap lock (SP , FIG 1) on the packer body (SP ,FIG 4) and do not overtighten, as galling may occur between the stainless steel surfaces; the O-ring seals at high pressure. Scratches, nicks or dents on the sealing surface of the Cap seal (SP , FIG 3), Nanobaume body 5

6 (SP , FIG 4) or O ring (SP , FIG 2) may impede sealing performance. As the Nanobaume is primarily 316 SS; ethers, concentrated oxidizing acids are not recommended. (i.e. Hydrochloric acid at greater than 10%) If small concentrations of aggressive solvents are used during packing, it is highly recommended that the unit be flushed with a weak solvent after use. 3. ASSEMBLY AND CONNECTION TO PRESSURE SOURCE PLEASE NOTE; THE FOLLOWING INSTRUCTIONS ARE WRITTEN TO INCLUDE COMPONENTS FROM THE SP-403K-M1 STARTUP KIT. CUSTOMERS WHO PURCHASED THE SP-400-M1 BASE UNIT MAY PURCHASE THESE PACKING ACCESSORIES SEPARATELY. 3.1 Remove the SP-400-M1 (FIG 5) and SP-403K-M1(FIG 6) components from the shipping container. Components shown on Page 4 FIG 5 FIG 6 NANOBAUME NANOBAUME ACCESSORY KIT SP-400-M1 KIT SP-403K-M1 KIT 3.2 Fit the Gauge Tee (SP-058) with the pressure gauge (SP-087). Wrap the ¼ NPT threads 3-4 times with teflon tape (TTB-50) Wrench tighten. 6.

7 FIG 7 FIG 8 FIG 9 FIG 10 Gauge tee, SP-058 Gauge,SP-087 PRESSURE FITTING, SP-116 SS TUBE, SP Place the SP-116 (FIG 9) nut and ferrule on the end of the SP-046(FIG 10) stainless steel tubing, tighten into the side port of the Nanobaume until tube is secure. The SP-116 is reusable as the ferrule does not swage permanently onto the tube. Connect the free end to the gauge tee (SP-087) and wrench tighten to secure the tube. Note: if a torque wrench is purchased, SP-162 torque to 10 Inch-pounds. If not, finger tighten the nut (Clockwise direction), then wrench tighten ¼ turn then check if leaks under pressure. If leaks occur, reduce pressure, ¼ turn more and repressurize, if leaks, repeat previous steps. Use this technique for tightening all Stainless steel nuts in this publication.) FIG 11 Pressure relief Valve with bottom drain, SP Using the second piece of SS tube (SP-046), Connect one end to the Pressure gauge Tee (SP-087), and other end to the Pressure vent valve (SP-050, FIG 11). Wrench tighten both until tubes are secure using technique described in 3.3. The assembly should look like Fig

8 FIG 12 FIG 13 FIG 14 SET UP SS TUBE, SP-055 REGULATOR ADAPTER SP Connect the uppermost port of the Vent valve (SP-050, ) to the pressure source. First use the Long piece of SS tube (SP-055, FIG 13) connect using fitting provided on the vent valve (upper port, right side of FIG 11) tighten to secure the tube. Take the SP-110, FIG 14 Pressure Regulator Adapter,1/4" male NPT end and apply teflon tape to threads wrapping 3-4 times around then thread into the port of the pressure regulator(not provided). Take the free end of the tubing and place into the other end of the pressure regulator adapter, and tighten until the tube is secure. If the HPLC pump is being used for the high pressure line, connect directly to pump using a female thread union (SP-095 not provided) 4. COLUMN ASSEMBLY 4.1 If fused silica tube will be used, cut the fused silica to length using an appropriate cutting tool. A precision cutter will ensure a square end without fragmentation of the column end (SP-019, not provided). Secure the column end fitting CE-003,( FIG 15), on the exit end of the column using an appropriate adapter sleeve,(ts-015,fig 20) with Nut, ( SP-130, FIG 22) and Ferrule,( SP-133, FIG 23). The ferrule nut- sleeve fused silica combination should look like figure 21. Tighten until fingertight and then 1/4 turn more to secure the column to the end fitting. Be sure to push the column body into the end fitting to eliminate a void between the column end and the web of the union. FIG 23.5 NUT, FERRULE ASSEMBLY SP-130/SP-133 FIG 15 FIG 16 FIG 17 FIG 18 COLUMN END, CE-003 SS FERRULE, SP-092 SS NUT, SP-102 SS UNION, SP Assemble the Column end fitting columns 1/32 OD or smaller, use the CE-003 From the CE-003 kit, 8.

9 place a 0.5um screen (SP-088, not shown) into the Micro Union (SP-089, FIG 15). Ensure that the screen is set in flat against the bottom web of the union. Place the 1/32 inch OD tube or fused silica ( adapted to 1/32 OD ) thru the nut (SP-102, FIG 17) and ferrule (SP-092, FIG 16) These are provided with the union. Insert the column body into the union and while exerting pressure on the tube into the union, tighten the nut using two wrenches. Use similar procedure for the CE-006 kit for 1/16 od column bodies, follow steps 4.2. FIG 19, FUSED SILICA WITH FIG 20,TS-015 ADAPTER SLEEVE FIG 21, PEEKSIL WITH SP-130/SP-133 FERRULE SP-015, NUT SP-014 FIG 22 FIG 23 FIG 24 FIG 25 SP-130 SS NUT SP-133 FERRULE SP-015 FERRULE 360um SP-014 SS NUT use SP-133 or SP-134 ferrule use sp-130 nut use SP-014 nut use SP-015 ferrule 4.3 The nut ferrule fused silica should look like fig 19. The sleeve on the fused silica will bring it up to an outside diameter of.032 (1/32") to fit the column end fittings (CE-003) Note; that the use of the fused silica will reduce the pressure rating of the column and packer to 6000 psig. 9.

10 4.4 LC-MS tips are inserted into the appropriate ferrule, and/ or sleeve depending on OD, and do not require end fittings as the tips are fritted already. 5. SLURRY PREPARATION 5.1 PLEASE NOTE: AS CAPILLARY PACKING IS AN EXPERIMENTAL SCIENCE, SOME TESTING WITH VARIOUS SOLVENTS OR COMBINATIONS MAY BE REQUIRED FOR OPTIMAL PACKING. 5.2 Weigh 100 mg of bulk packing material into the 2ml vial (VL-002, FIG 26) Add 1.5ml of appropriate solvent, or buffer (Hexane for normal phase, Propanol or acetonitrile for reversed phase, weak buffer for ion exchange) to the vial. Add the stir bar ( SP-085, FIG 27) FIG 26 FIG 27 FIG 28 VIAL VL-002 STIR BAR SP-085 VIAL INSERT SP Place the vial on a magnetic stir plate. Allow the slurry to stir for 5 minutes or until the stationary phase is well wetted. Once the bonded phase is wetted insert the vial into the packer body cavity using the vial insert (SP-125, FIG 28) provided to hold the vial in place 10.

11 6. ATTACHMENT OF COLUMN TO NANOBAUME FIG 29 FIG 30 FIG 31 FIG 32 FUSED SILICA 360um PEEKSIL 1/32 1/16 OD FERRULE SP-134 SP-014/SP-015 SP-133 nut ferrule assembly, FIG 33 SLEEVED FUSED SILICA nut SP-130/ ferrule SP-133 FIG 34 COLUMN ON NANOBaume nut SP-130/ ferrule SP With the correct adapter, most column or tubing with an outer diameter of 1/32inch or less can be attached to the Nanobaume(FIG 29 OR 30) using the nut,sp-130 ( FIG 22)And ferrule, SP-133 (FIG23). Larger 1/16 OD columns can be attached FIG 31, using the SP-130 (FIG 32 )nut and the Ferrule SP-134 (FIG 32) ferrule combination to the Nanobaume. In the SP-400-M1 kit, three adapter ferrules are provided. For 360 um OD fused silica use the SP-014 nut with the SP-015 ferrule. For 1/32inch OD tube use the SP- 130 nut with the SP-133 ferrule. For 1/16 inch OD tube use the SP-130 nut with the SP-134 ferrule. These connections are a convenient way to connect column bodies to the Nanobaume. If the fused silica tube that has a different OD than 360, use an adapter sleeve from the TS-015 kit and the SP-130/SP-133 combination. The adapters in the TS-015 kit will adapt fused silica columns of OD of 125 to 495 micron to a new OD of 1/32 to fit the SP-130/SP-133,( FIG 33) NOTE: USE OF FUSED SILICA WILL REDUCE THE OPERATING PRESSURE LIMIT TO 6000 PSIG 3) if not accomplished already. 6.2 Unscrew the Cap Lock (SP ,FIG 1) counterclockwise and remove the Cap Seal (SP , FIG 11.

12 FIG 34 FIG 35 COLUMN INSTALLED NANOBAUME SETUP IN CAP SEAL 6.3. Using the appropriate ferrule sized to the column OD, insert the column body open end through the ferrule and the nut (refer to section 6.1) Tighten the nut only finger tight into the threaded port of the Cap seal (SP FIG 34) column will be adjusted in the next step. 6.4 With the column in place, insert the Cap Seal onto the Nanobaume body,( FIG 33). Insure that the O ring is in place (figure FIG 2) Thread on the Cap Lock (SP , FIG 1) Hand tighten only as the O- ring under pressure forms the seal, not the fit of the cap lock and seal. DO NOT OVERTIGHTEN Push the column down into the slurry vial until it meets the bottom of the vial, then withdraw the column by 1/8 inch or far enough to clear the rotation of the stir bar at the bottom of the vial. 6.6 Tighten the Nut SP-130 (or the SP-014) to firmly secure the column in place ) Use two wrenches and the wrench flats on the Cap Seal to further tighten the nut. Overtightening the nut may embed the ferrule in the Cap seal port. If this problem occurs, take out the nut, and push the ferrule from the bottom side. Use a straight piece of 1/6 ss tube, or 1/32 Ferrule extraction tools are available. (contact the factory) 7.0 PACKING THE COLUMN and LC-MS TIPS NOTE: IF PACKING WITH LIQUID MEDIA, THE PACKING SOLVENT USED SHOULD BE THE SAME AS THAT USED TO SUSPEND THE SILICA SLURRY IN THE VIAL. IF PACKING WITH GAS, USE OF NITROGEN OR HELIUM IS RECOMMENDED. 7.1 Place the assembled Nanobaume and column behind a safety shield and onto a magnetic stir plate(not PROVIDED).The setup should approximate the setup shown ( FIG 35) Turn on the stir plate. 12.

13 With the bypass on the SP-050 (FIG 11) high pressure valve still open, slowly turn on the pressure source. The system pressure will vent through the bypass until the bypass is closed. 7.2 Slowly close off the bypass (clockwise turn) on the SP-050 valve handle to gradually increase pressure to the Nanobaume. If packing with liquid media, first flood the system and column with solvent. A small amount of air will be trapped inside the Nanobaume body and will be reduced in size by the pressure and not impact the packing process. Note: do not increase the packing pressure quickly as this might break the glass vial with differential pressure. 7.3 Set the flow rate to reach a stable pressure by adjusting the nitrogen tank regulator valve, or the liquid pressure source. As the slurry packs into the column, the pressure will rise. Take care to reduce the flow rate to ensure that the pressure limits of the end fitting, column to Nanobaume connection or the SP-400 pressure Vessel are not exceeded.. Flowrate and resulting pressure are interdependent. (More flow, higher the back pressure generated with a given bed length). 7.4 Monitor the pressure gauge (SP-087, FIG 8), watching for a stable pressure level. Although the column is packed once this stable pressure is reached, the silica bed is not yet stabilized. Allow the pressure source to maintain the column pressure for at least 60 minutes, longer is some cases up to 8 hours to reach a stable pack for longer columns. 7.5 For packing of the LC_MS Tips use gas and pack at pressure not exceeding 3000 psig. Tips pack quickly and visual confirmation is used in lieu of stable pressure reading. 8 COLUMN REMOVAL AND COMPLETION 8.1 Shut off the pressure source and relieve the system pressure by gradually opening the bypass on the SP-050 valve (counter-clockwise turn). 8.2 Remove the column from the Cap Seal, loosening the nut counterclockwise 2 full turns. Carefully remove the column from the cap seal. Note, removal of the column without equalizing pressure in all parts of the NANObaume setup, might cause the packing material to extrude from the open end of the column. Please refer to FIG 36, top column is fused silica column with sleeves, middle is the 1/32 PEEKSil column, and the bottom is a 1/16 SS body. These columns are not shown with the SS screens, as they are to small to photograph. 13.

14 FIG 36 COLUMNS READY FOR ENDS ATTACHEMENT, SCREENS NOT SHOWN 8.3 Install a suitable column end fitting onto the open end of the column (SECTION 4) (FIG 36) 8.4 The newly packed column may be attached to a pump to flush with suitable solvent to waste. The column is now complete and ready for use. NOTE: WE OFFER NO GUARANTEE REGARDING COLUMN TO COLUMN PACKING REPRODUCIBILITY, COLUMN EFFICIENCY (THEREOTICAL PLATES ACHIEVED), OR COLUMN SELECTIVITY OR TAILING FACTORS, CAPILLARY COLUMN PACKING IS AT THIS STAGE, A HIGHLY EXPERIMENTAL TECHNIQUE. WARNING; PACKING A HIGH PRESSURE CAN BE HAZARDOUS, DO NOT USE AT PRESSURE ABOVE RECOMMENDED LEVELS (9000 PSIG LIQUID, 3000 PSIG GAS) NOT FOR SFC(SUPERCRITICAL FLUID) column packing with CO2. 14.

15 PARTS AND ACCESSORIES Connection of the Nanobaume to a pressure supply source requires an adapter and several lengths of high-pressure tubing. Most of the replacement parts are found included in the kits shown in this brochure. Tubing and fittings Part Numbers Description SP-013 SP-014 SP-015 SP-116 SP-130 SP-133 SP-134 SP-046 SP-055 SP-051 Ferrule for 1/32" OD columns (use with the SP-014 nut) Nut SS, male threads, Use SP-013, SP-015 ferrules only Ferrule for 360um OD (Use with SP-014 nut only)fused silica Pressure source connection, male SS Nut SS, male threads, use SP-133, SP-134 ferrules only Adapter ferrule for 1/32 OD tube, use with SP-130 nut Adapter ferrule for 1/16" ID tube, use with SP-130 Nut. Tubing, SS 1/16" ODx.020" ID x 10cm long Tubing, SS 1/16" OD x.020 " ID, 5 ft long Adapter, 1/14" NPT to 1/16" OD tubing, for adapt pressure regulator Nanobaume Parts SP SP SP SP-058 SP-085 SP-087 SP-050 SP-125 Cap lock, SS with titanium nitride coating Cap Seal, SS "O" Ring, FFKM, perfluoroelastomer Gauge Tee, for 1/16" line and 1/4" NPT female gauge connection. Stir Bar, PTFE Coated, 5x2mm Pressure gauge, 0-10,000 psig, SS, 1/4" male NPT connection. Three way dump valve, for 10,000psig line, 1/16" inch fittings included. Vial insert, Kel-F for 2l 12x32mm flat bottom vials 15

16 SP-126 Vial insert, Kel -F for ml centrifuge vials VL-002x Glass vials, 2ml, borosilicate glass, 12x32mm, Pack of 10 vials Low pressure accessories (less than 3000 psig gas or liquid) SP-098 SP-029 SP-030 "O" Ring, Viton Pressure gauge for psig, SS, 1/4" NPT male connection PEEK green 1/16" od x.030" ID tubing 5 ft length Column End fittings Parts SP-088 SP-096 SP-089 SP-092 SP-103 SP-102 SP-095 SP-096 SP-135 SP-136 SP-137 Screen SS, 1/32" diameter with 0.5um sold each Screen SS, 1/16 diameter with 0.5um, sold each 1/32 SS micro-union including nuts and ferrules Ferrule, SS, 1/16 for SP-095 nion Ferrule, 1/32" for the SP-089 union Nut for the above SP-089 1/16" SS Micro-union including nuts and ferrules Screen, SS 1/16" micro union, 0.5um for the SP-095 SSI Ferrule 1/16" for SP-050 SSI Nut, 1/16" for High Pressure SP-050 Ferrule SS, OD 1/16" for the SP-058 Miscellaneous items SP-160 SP-161 SP-019 SP-162 SP-110 Three way SS valve 1/16 fittings, 2500psig limit Teflon tape for NPT threaded parts Precision Cutter for Fused silica Torque wrench 1/4inch Hex, 10 inch- pounds Pressure Regulator, Adapter, ¼ NPT threads to 1/16 tube, 16.

17 Kits CE-003 CE-006 CE-005 CE-007 Column end fitting kit, for 1/32 OD tube Column end fitting kit, for 1/16 OD tube Fitting kit for column adapters, 1/32 inch OD and smaller bodies Fitting kit for column adapters, 1/16 inch OD column bodies SP-400 mod 1 Nanobaume post SP-401 mod 1 Nanobaume Kit post TS-015 Adapter kits for increasing OD to 1/32 inch from fused silica OD of 125 to 495 micron Fused silica Tubing Adapters (PEEK, 6000psig rated) Catalog number Description (For Fused silica of OD listed below) SP-068 dimension) SP-069 SP-070 SP-071 SP-072 SP-073 SP-074 SP-075 SP-076 SLEEVE, PEEK, 1/32 inch OD, adapting fused silica tube of um OD (Outside SLEEVE, PEEK, 1/32 inch OD, adapting fused silica tube of um OD SLEEVE, PEEK, 1/32 inch OD, adapting fused silica tube of um OD SLEEVE, PEEK, 1/32 inch OD, adapting fused silica tube of um OD SLEEVE, PEEK, 1/32 inch OD, adapting fused silica tube of um OD SLEEVE, PEEK, 1/32 inch OD, adapting fused silica tube of um OD SLEEVE, PEEK, 1/32 inch OD, adapting fused silica tube of um OD SLEEVE, PEEK, 1/32 inch OD, adapting fused silica tube of um OD SLEEVE, PEEK, 1/32 inch OD, adapting fused silica tube of um OD PEEKSIL Empty column bodies 1/32" OD Catalog number description pressure rated SP um ID x 1/32" OD, 50mm long, pack of 2 10,000 psig SP um ID x 1/32" OD, 100mm long, pack of 2 10,000 psig SP um ID x 1/32" OD, 150mm long, pack of 2 10,000 psig SP um ID x 1/32" OD, 50mm long, pack of 2 10,000 psig 17.

18 SP um ID x 1/32" OD, 100mm long, pack of 2 10,000 psig SP um ID x 1/32" OD, 150mm long, pack of 2 10,000 psig SP um ID x 1/32" OD, 50mm long, pack of 2 10,000 psig SP um ID x 1/32" OD, 100mm long, pack of 2 10,000 psig SP um ID x 1/32" OD, 150mm long, pack of 2 10,000 psig SP um ID x 1/32" OD, 50mm long, pack of 2 10,000 psig SP um ID x 1/32" OD, 100mm long, pack of 2 10,000 psig SP um ID x 1/32" OD, 150mm long, pack of 2 10,000 psig SP um ID x 1/32" OD, 50mm long, pack of 2 8,500 psig SP um ID x 1/32" OD, 100mm long, pack of 2 8,500 psig SP um ID x 1/32" OD, 150mm long, pack of 2 8,500 psig Use CE-003 for column end fittings PEEKSIL Empty Column Bodies 1/16" OD Catalog number description pressure rated SP um ID x 1/16" OD, 150mm long, each 10,000 psig SP um ID x 1/16" OD, 200mm long, each 10,000 psig SP um ID x 1/16" OD, 150mm long, each 8,500 psig SP um ID x 1/16" OD, 200mm long, each 8,500 psig SP um ID x 1/16" OD, 150mm long, each 6,500 psig SP um ID x 1/16" OD, 200mm long, each 6,500 psig Use CE-006 for column end fittings 1/32, 1/16 OD ; Other PEEKSil ID s and Lengths are available, in precut lengths; Please inquire Bulk Bonded Phase Supports, Bulk sold by the gram SP-008 SP-004 SP-005 Strong Cation Exchange, PolySulfoethyl A 5u, 300A Weak Cation Exchange, PolyCAT A 5um, 1000A Hydrophillic Interaction, (HILIC) PolyHYDROXYethyl A, 5um, 300A 18.

19 SP-007 SP-006 SP-002 SP-001 Hydrophobic Interaction (HIC) Polypropyl A, 5um 300A C-18, 5um, 300A C-18, 5um, 100A, Hydrophillic endcap C-18, 5um, 100A Fused Silica Column Bodies and transfer tubing Deactivated Fused Silica Tubing, sold in 1 meter length SP-009 SP-010 SP um ID x 363 um OD Deactivated methyl 100um ID x 365um OD Deactivated methyl 250 um ID x 350um OD, Deactivated Methyl Un-Deactivated Fused Silica, sold in 1 meter length SP-059 SP-060 SP-061 SP-062 SP-063 SP-064 SP-065 SP-066 5um ID x 363um OD, Un-Deactivated 10um ID x 363um OD, Un-Deactivated 20um ID x 363um OD, Un-Deactivated 50um ID x 363um OD, Un-Deactivated 75um ID x 363umOD, Un-Deactivated 100um ID x 363um OD, Un-Deactivated 200um ID x x363um OD, Un-Deactivated 250um ID x 363 um OD, Un-Deactivated Fused tubing Cutter SP-019 Precision Tube Cutter for fused silica. 19.

20 Nanobaume Operating Instructions REVISION Western Fluids Engineering LLC Lake Elsinore CA

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule One Piece or Two? A one-piece fitting is more convenient and less cumbersome, since the ferrule cannot stick in a receiving port and the fitting is more easily found if dropped. With two-piece Fingertight,

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax: 2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use

More information

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 3000 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator

More information

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve USER'S GUIDE Nanoflow Probe 3-4mm Red Stripe ptfe Sleeve To Injector ZU1XC Fused Silica 20µm 90µm TTF115 ptfe Sleeve Fused Silica 25µm 375µm Micromass UK Limited Floats Road Wythenshawe M23 9LZ Tel: +44

More information

GILMONT ACCUCAL FLOWMETERS

GILMONT ACCUCAL FLOWMETERS OPERATING MANUAL GILMONT ACCUCAL FLOWMETERS 28W092 Commercial Ave. Barrington, IL U.S.A. 60010-2392 (847) 381-4888 (847) 381-7053 (Fax) 800-962-7142 www.barnant.com e-mail: barnant@barnant.com A-1299-0766

More information

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing

Connectors. SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses. Top Seller SEE STARRED PRODUCTS. VHP Tees & Crosses for Capillary Tubing SECTION 2 OF 3 SECTIONS ON CONNECTORS VHP Tees and Crosses VHP Tees & Crosses for Capillary Tubing VHP Tees & Crosses for 1/16 OD Tubing IDEX Health & Science offers Very High Pressure, designed to bring

More information

Techcon Systems TS1258 Pressure Pot

Techcon Systems TS1258 Pressure Pot Techcon Systems TS1258 Pressure Pot User Guide TABLE OF CONTENT 1. SAFETY. 3 1.1 Intended Use 3 1.2 Safety Precaution 3 2. CERTIFICATE OF COMFORMANCE 4 3. FEATURES. 5 4. SPECIFICATIONS 5 5. INSTALLATION

More information

Techcon Systems TS1254 Pressure Pot

Techcon Systems TS1254 Pressure Pot Techcon Systems TS1254 Pressure Pot User Guide Copyright OK International, Inc. TABLE OF CONTENT 1. SAFETY. 3 1.1 Intended Use 3 1.2 Safety Precaution 3 2. FEATURES. 5 3. SPECIFICATIONS 4 4. INSTALLATION

More information

Avenger Model 33M Installation & Operation Instructions

Avenger Model 33M Installation & Operation Instructions Avenger Model 33M Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737 Phone:

More information

SCF Enviro-Friendly. Back-up Ring. Endcap. #7141 (for both) O-Ring. Back-up ring and O-ring fit onto end cap.

SCF Enviro-Friendly. Back-up Ring. Endcap. #7141 (for both) O-Ring. Back-up ring and O-ring fit onto end cap. Extraction Parts 5mL - 50mL Closure Nut Male Fitting #7943 (2 required) Metal Frits #7942 (2 required) Endcap Back-up Ring O-Ring #7141 (for both) Body The components shown are the parts of a complete,

More information

Axial Compression Packing Method

Axial Compression Packing Method GE Healthcare Life Sciences Axial Compression Packing Method Method Description The axial compression packing method is quite easy and requires a minimal amount of equipment. It is useful for situations

More information

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 7/26/2011 Ver. 2.2 4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information

4400 TwinHybrid Gas Seal

4400 TwinHybrid Gas Seal 4400 TwinHybrid Gas Seal EQUIPMENT PREPARATION MECHANICAL SEAL INSTALLATION INSTRUCTIONS 1 2 200.005" 0,13 mm 125 µ" 3,2 µm R a 3 4 32 µ" 0,8 µm R a 1000 ±.002" 0,05mm CAUTIONS These instructions are general

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691 THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

PANACEA P200 STAINLESS STEEL USER MANUAL

PANACEA P200 STAINLESS STEEL USER MANUAL Basic Features Stainless Steel body with 1.75 outside diameter. Will fit into wells down to 2 (schedule 80). Has an internal chamber volume of 200mL. Maximum depth below ground surface of 3000ft. Other

More information

INSTALLATION & MAINTENANCE INSTRUCTION

INSTALLATION & MAINTENANCE INSTRUCTION ARCHON Industries, Inc Liquid Level Gauges Models: BT-LLG ND-LLG INSTALLATION & MAINTENANCE INSTRUCTION Instruction No.: 1014.2 Revision Issued: 3/01/03 Approved: Engineering Manager Warning ONLY QUALIFIED

More information

DS06D,G Dial Set Pressure Regulating Valve

DS06D,G Dial Set Pressure Regulating Valve DS06D,G Dial Set Pressure Regulating Valve PRODUCT DATA FEATURES APPLICATION Built-in, factory-calibrated outlet pressure adjustment dial. Noncorroding unitized cartridge contains all working parts and

More information

SIMPLAIR PIPING TOOL. JXT Company

SIMPLAIR PIPING TOOL. JXT Company SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7 EXEL North America, Inc. EXEL Industrial Canada, Inc. 1310 Washington St 931 Progress Ave., #7 West Chicago, IL 60185 Scarborough ONT, M1G 3V5 Ph : (800) 573 5554 Ph : (800) 450 0655 Fx : (800) 664 1511

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Probe Instrument Regulator Model The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for

More information

Operation Manual Piston Sensed Gas Pressure Regulators

Operation Manual Piston Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:

More information

1805 Series Relief Valves

1805 Series Relief Valves Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion

More information

Constant Pressure Crude Oil Container Model CPCCP

Constant Pressure Crude Oil Container Model CPCCP Installation, Operations, and Maintenance Manual Constant Pressure Crude Oil Container Model CPCCP The information in this manual has been carefully checked for accuracy and is intended to be used as a

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information

HICHROM. HPLC Accessories

HICHROM. HPLC Accessories HICHROM HPLC Accessories HICHROM Index PEEK Tubing SLIPFREE HPLC Column Connectors 1 Stainless Steel Tubing 7 PEEK Unions, Tees and Crosses 8 2 Micro Flow Fittings Tubing Cutters 9 3 Fingertight Fittings

More information

UWPR. LC-MS setup. Before you connect your trap and column. Connecting your trap and column

UWPR. LC-MS setup. Before you connect your trap and column. Connecting your trap and column Before you connect your trap and column You need to provide your own trap and column (Note our fittings accommodate trap and column made with fused silica 360 µm OD). Check our guide for packing traps

More information

1200B2 Series Service Regulators. Instruction Manual

1200B2 Series Service Regulators. Instruction Manual 00B Series Service Regulators Instruction Manual 00B Series Service Regulators 0 Elster American Meter 00B Series Service Regulators General Information The 00B Series Service Regulators are available

More information

Zero Head Space Extractor. Catalogue No. YT HW. Operation and Maintenance Manual

Zero Head Space Extractor. Catalogue No. YT HW. Operation and Maintenance Manual Catalogue No. YT30 090 HW Operation and Maintenance Manual ABOUT THE ZERO HEAD SPACE EXTRACTOR The Millipore Zero Head Space Extractor (ZHE) meets the U.S. EPA'S Toxicity Characteristics Leaching Procedure

More information

INSERT FITTINGS INSERT FITTINGS

INSERT FITTINGS INSERT FITTINGS Insert Tee Insert x Female Tee Insert Elbow Insert x Male Elbow Insert Coupling Insert x Male Adapter Insert x Female Adapter Insert Plug POLY and NYLON FITTINGS For use with Poly Tubing Fitting 1/2 3/4

More information

Crimpers and Decappers

Crimpers and Decappers Crimpers and Decappers Adjustable Hand Crimper Adjustable block corrects for differences in septum thicknesses The Adjustable Crimper has an adjustable pressure block in the crimper head that allows crimping

More information

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Operation Manual. Diaphragm Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Diaphragm Sensed Gas (AP/AZ/AK Models: 20, 100, 500, 1000, 1000T 10PA, 1100, 1200, 12PA, 1300, 1400T, 14PA,

More information

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

High Pressure Equipment Taper Seal Valves, Fittings and Tubing igh quipment Taper Seal Valves, ittings and Tubing 0,000 and,000 psi service igh quipment Company has developed the Taper Seal line of products to assure safe and easy plumbing through,000 psi. These needle

More information

PANACEA P125 USER MANUAL

PANACEA P125 USER MANUAL Basic Features Stainless steel body with 1.125 outside diameter. Will fit into wells down to 1-1/4 (schedule 80). Uses static water pressure to fill gas and sample return tubes. Maximum depth below ground

More information

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL Prepared by CR Manning Edited by SC Woidtke Rev August 22, 2011 PRESSURIZED WATER VESSEL OPERATING MANUAL 1. Background 1.1 The Pressurized

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and

More information

Adjustable. Unloader Valve. O&M Manual. Part #

Adjustable. Unloader Valve. O&M Manual. Part # Adjustable Unloader Valve O&M Manual Unloader Valve Part #60-020-361 ADVANCED PRESSURE SYSTEMS 701 S. Persimmon St., Suite 85 - Tomball, TX 77375 Toll Free in North America: (877) 290-4277 Phone: (281)

More information

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below. Page 1 of 15 Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below. Model Number A25-XXXX-3.6K Series A40-XXXX-3K Series A40X-XXXX-3.6K Series A60-XXXX-3K

More information

TECHNICAL BULLETIN. Sigma-Aldrich Pure-Pac II System. Technical Bulletin AL-236

TECHNICAL BULLETIN. Sigma-Aldrich Pure-Pac II System. Technical Bulletin AL-236 Sigma-Aldrich Pure-Pac II System Technical Bulletin AL-236 TECHNICAL BULLETIN Product The Sigma-Aldrich Pure-Pac II packaging/dispensing system provides a convenient method for storing and dispensing laboratory

More information

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , & REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1

More information

B. Assemble the Method-25 sample train with a heated probe/filter.

B. Assemble the Method-25 sample train with a heated probe/filter. 6/30/2015 VOC Reporting, Inc. Method 25 Heated Controller Operating Instructions. pg. 1 of 5 INSTRUCTIONS FOR EPA METHOD-25 FIELD SAMPLE COLLECTION USING A VRi HEATED PROBE AND FILTER ASSEMBLY Introduction:

More information

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator) INTRODUCTION Binks SG-2 Plus TM Pressure Cup is ideal for component spraying and industrial applications where small batch production spraying is required. The 2 qt. capacity is sufficient to complete

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSURE PUMP To minimize vibration, it is best to build brackets on the motor itself, similar to alternator brackets. Use cardboard to construct a pattern first before making

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

D05T Compact Design Pressure Regulating Valves

D05T Compact Design Pressure Regulating Valves D05T Compact Design Pressure Regulating Valves FEATURES PRODUCT DATA Non-corroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass.

More information

2.0 INSTALLATION & SERVICE

2.0 INSTALLATION & SERVICE Installation, Operation, and Maintenance Instructions MODEL 5600 / 5600R January 2005 CONTENTS 1.0 GENERAL 1.1 5600 Model Number Information -----------------------------------------------------------------------

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

PXRF- Tracer Helium Flow Control System

PXRF- Tracer Helium Flow Control System PXRF- Tracer Helium Flow Control System This flow control system was designed to regulate the gas flow from a helium (He) balloon tank containing 8.9 cu ft (0.25 cu m). Tank not included with the system.

More information

Anti-flood device Model B-1

Anti-flood device Model B-1 December 4, 2009 Dry Systems 123a 1. DESCRIPTION The Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET

More information

Portable Hydrostatic Pneumatic Test Pump. Procedure Manual

Portable Hydrostatic Pneumatic Test Pump. Procedure Manual Portable Hydrostatic Pneumatic Test Pump Procedure Manual Dixon Valve & Coupling Company 800 High Street Chestertown, MD 21620 800-355-1991 Fax: 800-283-4966 Specifications Dixon Portable Pneumatic Hydrostatic

More information

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze

More information

OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range Lab scale nanofiltration equipment The METcell Range OVERVIEW METCELL SPECIFICATIONS The METcell range of equipment was designed by us to be an easy entry point for scoping separations process development

More information

Manual Solvent Purification System. Innovative Technology, Inc.

Manual Solvent Purification System. Innovative Technology, Inc. Innovative Technology, Inc. 2 New Pasture Road, Newburyport, MA 01950-4054 USA Email: Info@gloveboxes.com TEL: +1 978 462 4415 FAX: +1 978 462 3338 Manual Solvent Purification System Copyright Innovative

More information

Cell Disruption System

Cell Disruption System BioNeb Cell Disruption System* Instruction Manual * U.S. patent number 550100 International patents issued and pending BioNeb Cell Disruption System Instruction Manual Version 3.0, April, 2000 Edited by:

More information

LRS(H)4 Pressure-Reducing Regulator User Manual

LRS(H)4 Pressure-Reducing Regulator User Manual LRS(H)4 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be considered

More information

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968 Supplementary instructions Rod and cable components for VEGAFEX series 80 Document ID: 44968 Contents Contents 1 Product description 1.1 Extensions... 3 2 Mounting 2.1 General instructions... 6 2.2 Rod

More information

PANACEA P100 LOW PRESSURE USER MANUAL

PANACEA P100 LOW PRESSURE USER MANUAL Basic Features Stainless steel body with 7/8 outside diameter. Will fit into wells down to 1 (schedule 80). Uses static water pressure to fill gas and sample return tubes. Maximum depth below ground surface

More information

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions Before installation these instructions must be fully read and understood Installation and maintenance instructions for Series 93 Positive Pressure Pilot Operated Safety Relief Valves (POSRV). The intent

More information

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP Model No. 80-651 Rotary Agitator INTRODUCTION Binks SG-2 TM Plus Rotary 2 Qt. Pressure Cup is ideal for component spraying and industrial applications where

More information

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All

More information

1800C and 1800C-HC Series Service Regulators

1800C and 1800C-HC Series Service Regulators 1800C and 1800C-HC Series Service Regulators Installation Instructions www.elster-americanmeter.com General Information: The 1800C and 1800C-HC Regulators are available as Full Capacity Internal Relief

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

The Open-Split Capillary Interface. Part No

The Open-Split Capillary Interface. Part No The Open-Split Capillary Interface Part No. 113532 2 INTRODUCTION With the advent of fused silica capillary columns and their high degree of flexibility, it is obviously attractive to be able to take the

More information

Suggested Installation & Operating Instructions for Sidewinder Pumps

Suggested Installation & Operating Instructions for Sidewinder Pumps Model 164 C P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pump Suggested Installation & Operating Instructions for Sidewinder

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE MODELS RV-1 RV-2 RV-2CP RV-3 DRAWING NUMBERS AD017A[ ] AD018A[ ] AD020A[ ] AD282BO MANUAL NUMBER IOM-033 REVISION Rev. E, 3/28/2016 TABLE

More information

Operating Instructions Model and Hydrostatic Test Pump

Operating Instructions Model and Hydrostatic Test Pump Operating Instructions Model 29200 and 2920 Hydrostatic Test Pump Dimension Weight Pump Pressure for 29200 Pump Pressure for 2920 Gauge for 29200 Gauge for 2920 Inlet Connection Outlet Connection Hose

More information

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132 Paintball Marker User s Manual 530 South Springbrook Road Newberg, OR 97132 Component Concepts, Inc., 530 South Springbrook Road, Newberg, OR 97132 Phone: (503) 554-8095 Fax: (503) 554-9370 www.phantomonline.com

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

LNG Regulator Test Kit

LNG Regulator Test Kit OVERVIEW Chart provides a LNG Economizer/Regulator Test Kit to help save money and time by allowing a technician to more accurately and easily diagnose the operability of the pressure control regulator/economizer

More information

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP Installation, Operation, and Maintenance Manual Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model The information in this manual has been carefully checked for

More information

RD(H)20/25 Pressure-Reducing Regulator User Manual

RD(H)20/25 Pressure-Reducing Regulator User Manual RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be

More information

START UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see

START UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see START UP MANUAL MADE IN USA 004-027-8896-00 REV 033116 295 East Corporate Place Suite 100 Chandler, AZ 85225 Toll Free: 1.800.621.5886 Phone: 480.893.7607 Fax: 480.753.3397 Paramount@1Paramount.com www.1paramount.com

More information

Pneumatic Powered - Plunger Pumps

Pneumatic Powered - Plunger Pumps Models 42/62/82 D Series P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pumps Suggested Installation & Operating Instructions

More information

CATALYZER TM 2K 10:1 RATIO Pump

CATALYZER TM 2K 10:1 RATIO Pump PRODUCT INFORMATION CATALYZER TM 2K 10:1 RATIO Pump The C.A.Technologies CATALYZER is an Air Assist Airless 2 component formulator. Catalyst and base material are pumped into a mixing chamber at 10 : 1

More information

Operating Instructions

Operating Instructions Operating Instructions Multifunction Valve Contents Page Safety Instructions... 2 Unpacking... 2 Introduction... 2 Dimensions... 4 Installation...2-3 Description of Controls & Operation... 3 Page Helpful

More information

COMPRESSION TUBE FITTINGS

COMPRESSION TUBE FITTINGS COMPRESSION TUBE FITTINGS 1/16 THROUGH 2 2 MM THROUGH 50 MM LET-LOK TUBE FITTINGS DESCRIPTION The HAM-LET GROUP has produced high quality tube and pipe LET-LOK HOW DOES IT WORK? A HAM-LET has gained an

More information

Advanced Fluid Handling Cart Owner s Manual

Advanced Fluid Handling Cart Owner s Manual Advanced Fluid Handling Cart IMPORTANT Please read this carefully and thoroughly before installing and operating your Advanced Fluid Handling Cart. Please retain this owner s manual for future reference

More information

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...

More information

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301 THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...

More information

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER MODEL CP-11 DRAWING NUMBERS AD157CO AD157CP.CE MANUAL NUMBER IOM-184 REVISION Rev. B, 6/7/2018 TABLE OF CONTENTS SAFETY

More information

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle

More information

64 Series Pressure Reducing Regulators

64 Series Pressure Reducing Regulators Instruction Manual Form 1245 64 Series March 2006 64 Series Pressure Reducing Regulators W1943 Figure 1. 64 Series Regulator Introduction Scope of Manual This manual provides instructions for the installation,

More information

MEGR-1627 Instruction Manual

MEGR-1627 Instruction Manual MEGR-1627 HIGH FLOW GAS REGULATOR Instruction Manual- Look Inside For: Description Installation Remote Vent Line Installations Startup and Adjustment Shutdown Maintenance Body Maintenance Procedures Diaphragm

More information

D05 Pressure Regulating Valves

D05 Pressure Regulating Valves D05 Pressure Regulating Valves FEATURES PRODUCT DATA Noncorroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass. Balanced seat construction

More information

DuraSite 3000 Sample Vessel User's Guide. Version Rev-1

DuraSite 3000 Sample Vessel User's Guide. Version Rev-1 DuraSite 3000 Sample Vessel User's Guide Version 09022003 Rev-1 2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application

More information

ATIS OPERATION MANUAL

ATIS OPERATION MANUAL ATIS OPERATION MANUAL Adsorbent Tube Injector System T702019A 1 Introduction The Adsorbent Tube Injector System (ATIS) is a sample preparation device that provides a quick and efficient way to transfer

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

Storage Systems and Accessories

Storage Systems and Accessories Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single

More information

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI Jetstream offers a wide variety of fittings with various connection types to fit your 20,000 psi application needs. The standard connection types, Type M, MP, and MP Tube lance, are available in standard

More information

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2 operating Instructions manual MUELLER GAS TAble of contents PAGE No-Blo Operations Using D-5 General Information 2 Installing No-Blo Service Tees, Service Stop Tees and Curb Stop Tees 3-8 Reconditioning

More information

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT. OPERATOR S MANUAL TP0411G2XXXXXXXX INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE. RELEASED: 2-15-10 INCLUDE MANUALS: AF0411GXXXXXX-XX-X Two-Ball Pump (97999-1496), 66731-X Follower Assembly (pn REVISED:

More information

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION TO AVOID POSSIBLE INJURY Warning: Always consider any accumulator to contain pressure until proven

More information

Float Operated Level Controllers

Float Operated Level Controllers CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions

More information

Dean Pump Self-Priming Chemical Process Pumps

Dean Pump Self-Priming Chemical Process Pumps Bulletin C 1.2.34.7 Dean Pump Self-Priming Chemical Process Pumps php Series HEAD CAPACITY RANGE CHARTS php Self Primer - 2 Pole 3500 RPM 500 CAPACITY M 3 /HR 2900 RPM 50 HERTZ 25 50 75 125 150 400 TOTAL

More information

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves. JSR Series High Purity Bio-Pharma Gas Pressure Reducing Valves JSR is the first high purity gas pressure regulator designed and built specifically for hygienic, ASME BPE gas applications. Traditionally,

More information

Super-Clean Gas Filters from Restek

Super-Clean Gas Filters from Restek Super-Clean Gas Filters from Restek Chromatography Products www.restek.com 800-356-688 84-353-300 regulator instrument-grade tubing on/off valve GC carrier gas moisture trap hydrocarbon trap high-capacity

More information

Capillary Conversion System CCS-4/NC & CCS-05/NC. Installation and Operating Instructions. Operating Instructions

Capillary Conversion System CCS-4/NC & CCS-05/NC. Installation and Operating Instructions. Operating Instructions Operating Instructions Check the detector for the correct operating conditions. If make-up gas is being used a flow of 30ml/min. of carrier plus make-up is normally recommended. This can most effectively

More information

Combination Air Valve

Combination Air Valve Combination Air Valve For Sewage and Wastewater Model C50 Installation, Operation and Maintenance Manual (IOM) Table of Contents General... Page 2 Safety... Page 2 Operational Data... Page 3 Materials

More information