Fraction Collectors: Frac-950 and Frac-920
|
|
- Sybil Horn
- 5 years ago
- Views:
Transcription
1 GE Healthcare Data file AE Fraction collectors Fraction Collectors: Frac-950 and Frac-920 Introduction Fraction collectors Frac-950 and Frac-920 are automated for reliable and flexible collection of fractions based on time or volume as part of an ÄKTA design chromatography system. Frac-950 (Fig 1) has advanced functionality for both standard and preparative mode that allows large volume fraction collection. Frac-950 can also easily be equipped with an optional Microfraction Collection Kit, enabeling reproducible collection of volumes down to 40 µl. Frac-920 (Fig 2) has a carousel design, small footprint, and can be used with laboratory systems or as a stand-alone instrument. Reliable and easy-to-use Robust design No sample loss Simple programming Cold room compatible Fig 1. Fraction collector Frac-950. Collect in the vessel you need Wide range of standard collection vessels Preparative mode for large volume fractions with Frac-950 Collect the fractions you want Peak fractionation based on slope or threshold Time- or volume-based collection Microfraction Collection Kit, for reproducible collection of fraction volumes down to 40 µl Fig 2. Fraction collector Frac-920.
2 Frac-950 for advanced flexible fraction collection Fractions can be collected from practically any size of labscale chromatography column, from 96-well microplates, standard 12, 18 or 30 mm tubes or in 250 ml bottles. Even larger vessels can be used at flow rates up to 100 ml/min. Spillage and sample loss between vessels at low and high flow rates is prevented by drop synchronization or by the built-in accumulator. Peak detection is based on slope or threshold detection, allowing fractionation to be controlled with the minimum of peak overlap and dilution of significant fractions. Frac-950 is controlled simply and directly by UNICORN as an integral part of your ÄKTAexplorer, ÄKTApurifier, ÄKTAfplc, or ÄKTAmicro system. Collect in the vessel you need Collecting fractions in the right kind of vessel helps optimize workflows, whether checking the results of cloning experiments or preparing large amounts of material for a routine application. In the standard mode, fractions can be collected in 96-well microplates (up to four) and 12 mm, 18 mm or 30 mm standard tubes (Fig 4). To avoid collecting unnecessary numbers of small fractions, standard racks A and C have extra positions where larger fractions from wash steps can be collected in 30 mm tubes. Large volumes are managed in preparative mode that allows fraction collection in eighty 30 mm tubes, twenty 250 ml bottles or in thirty funnels (Fig 5) connected to practically any vessel. Robust design with few moving parts Mechanical reliability is essential in any fraction collector so the smaller the number of moving parts the better. In its standard mode, Frac-950 uses a stationary collection head and two simple rotational movements (Fig 3) to position the collection vessel accurately and quickly to collect the next fraction. Large volume fractions are collected in the preparative mode by moving the collection head with the same two motions. Rack A: mm tubes 8 30 mm tubes Rack B: mm tubes Rack C: 4 microplates (96 fractions per plate) 8 30 mm tubes Rack D: mm tubes Rack E: mm tubes Rack F: ml bottles Fig 4. Available racks for Frac-950. Rack E and F require a Prep Mode Conversion Kit. Fig 3. The Frac-950 positioning system. Using Rack C, each well in four microplates and each of eight standard 30 mm tubes can be positioned precisely and reliably under the stationary collection head. Two independent ways to prevent sample loss Valuable materials must be collected without spillage or loss between collection vessels. Frac-950 achieves this both at low flow rates and at high rates up to 100 ml/min. At low flow rates, fraction changes are synchronized to occur between drops. Since the collection head is stationary in the standard operating mode there is no risk of hanging drops being flicked off. At high flow rates, liquid flow can be diverted to an accumulator during the short time it takes to move to the next collection position. The diverted liquid is then dispensed and collected securely and completely. Fig 5. Frac-950. The preparative mode also accommodates up to thirty very large fractions AE
3 Frac-920 for robust fraction collection Fraction collector Frac-920 has functionality and design that makes it ideal for lab-scale chromatography. The robust design with a minimized footprint also saves bench space. The fraction collector is programmable and easy to use in connection with UNICORN and ÄKTA design chromatography systems or as stand-alone instrument. Fixed volume and time fractionation as well as automatic peak fractionation are possible. Peak fractionation is based on peak detection using slope or level sensing and event marks clearly identify the fractions and peaks. Frac-920 comes with three tube racks to allow collection of up to 95 fractions in mm diameter tubes or up to 175 fractions in 12 mm diameter tubes and up to 40 fractions in 30 mm tubes. An optional flow diversion valve SV-923 allows flow diversion to waste. Simple programming with UNICORN Both Frac-950 and Frac-920 can be run in many different ways to collect the fractions you need for your further work. Operation as an integral part of your ÄKTA design system is simple and direct using UNICORN 3.2 or higher (Fig 6). For prep mode Frac-950 requires UNICORN 4.0 or higher. Select rack type Select fractionation order If the same small fraction size is used throughout the separation, then there will be many fractions at the beginning containing nothing of interest, simply making work. If the fraction size is made large to reduce the number of tubes to be assayed, then proteins separated on the column will be re-mixed in the collected fractions. By analyzing the monitor signal, UNICORN can determine just when the separated proteins are eluted from the column and collect fractions to match. As can be seen from Figure 7, cross-contamination of proteins can be significantly reduced by monitoring the peak slope. When a shoulder on a peak or a valley between two incompletely resolved peaks is detected, UNICORN can instruct the fraction collectors to change fractions at the best time to preserve resolution. Between well-separated peaks or at the beginning or end of a run, fractions with little or no protein can be diverted to waste or collected as a few large fractions as a safeguard (racks A and C have extra positions for 30 mm tubes that are ideal for this purpose) mau UV Cond Fractions Minimizes crosscontamination ms/cm Minimizes dilution 10.0 Select tube type and size Select fractionation size Select fractionation order Select tube type and size ml Fig 7. Automatic peak fractionation can help reduce peak overlap and peak dilution. Collection of small sample volumes Micropreparative purification has rigid requirements when working with accurate and reproducible collection of small sample volumes. The optional Microfraction Collection Kit (Fig 8) allows reliable collection of microliter fraction volumes as low as 40 μl directly into microplates (the recommended volume range is from 500 μl/min and below). Fig 6. UNICORN defines your fractionation scheme to suit your exact requirements. Collect the fractions you want Frac-950 and Frac-920 have the capacity to collect fractions in many kinds of vessels and over the whole flow rate range of ÄKTA design chromatography systems under the control of UNICORN. To achieve the best results it is important to preserve the resolution obtained from the column all the way to the collection vessel. The automatic peak fractionation functions in UNICORN enable the fraction collectors to work optimally. Fig 8. Fraction Collector Frac-950 (left) and (right) Frac-950 modified for collection of extremely small fraction volumes using tubing provided in Microfraction Collection Kit AE 3
4 Technical specifications Frac-950 Operating data Max. flow rate 100 ml/min ph stability range 1 to 13, 1 to 14 (<1 day exposure) Fraction size Volume mode: ml Time mode: min No spillage range Dropsync. range: ml/min Accumulator range: ml/min Environment +4 C to +40 C 20% 95% relative humidity kpa ( mbar) atmospheric pressure Frac-950 Tube racks Rack designation Tube Max number and color combination of fractions Rack A, yellow 18 mm tubes mm tubes 8 Rack B, violet 12 mm tubes 240 Rack C, blue 96-well microplates mm tubes 8 Rack D, red 30 mm tubes 45 Preparative mode Rack E, cream 30 mm tubes 80 Rack F, green 250 ml bottles 20 Funnel to Flask Funnels 30 (used with Rack E) 1 The following manufacturers microtitre plates are tested and approved by GE Healthcare to be used with this rack type: Greiner low: , , Greiner high: Nunc low: , , , The differences between these articles are in the shapes of the bottoms of the wells and the inclusion of a lid in some cases. All articles have 96 wells. Frac-950 Physical data Degree of protection IP 21 Wetted materials PEEK (polyetheretherketone) UHMW-PE (ultra high molecular weight polyethylene) Glass Elgiloy HT Chemical resistance The wetted parts of the instrument are resistant to organic solvents and salt buffers commonly used in chromatography of biomolecules, except 100% ethyl acetate, 100% hexane and100% tetrahydrofuran (THF) Power requirement / VAC, Hz (autorange switching) Power consumption 300 VA Dimensions, H W D mm Weight 16.5 kg Frac-950 Ordering information Item Code no. Fraction collector Frac-950 (including Rack A) Fraction collector Frac-950 requires an ÄKTA design system controlled by UNICORN v 3.2 or higher. To use the preparative mode (requires UNICORN 4.0), order Fraction collector Frac-950 together with Prep Mode Conversion Kit , and at least one of Rack E or Rack F Related product literature Data Files Code no. ÄKTAexplorer chromatography systems ÄKTApurifier chromatography systems UNICORN Control System ÄKTAmicro chromatography systems Accessories and consumables Item Quant./pack Code no. Microfraction Collection Kit Rack A, complete with bowl for 18 mm and 30 mm tubes Rack B, complete with bowl for 12 mm tubes Rack C, complete with bowl for 96-well microtitre plates and 30 mm tubes Rack D, complete with bowl for 30 mm tubes Prep Mode Conversion Kit (for use with Rack E and Rack F) Rack E, complete for 30 mm tubes Rack F, complete for 250 ml bottles Funnel to Flask Kit with funnels, tubing, and tubing organizer (for use with Rack E) PEEK tubing i.d mm, o.d. 1/16" 2 m PEEK tubing i.d mm, o.d. 1/16" 2 m PEEK tubing i.d mm, o.d. 1/16" 2 m PEEK tubing i.d mm, o.d. 1/16" 2 m Fingertight connector 1/16" Mains distribution cable, for connection to ÄKTA design 1 m UniNet cable 1.5 m UniNet cable 0.7 m UniNet cable 3 m UniNet cable 15 m EMC standards This device meets the requirements of the EMC Directive 89/336/EEC through the following harmonized standards: EN (emission and immunity) EN 55011, GR 2, Class A (emission) This device complies with part 15 of the FCC rules (emission). Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference recevide, including interference that may cause undesired operation AE
5 Technical specifications Frac-920 Operating data Max flow rate ph stability range Fraction size Environment Frac-920 Tube Racks 100 ml/min 1 to 13, 1 to 14 (<1 day exposure) ml (0.1 ml increments) min (0.1 min increments) +4 C to +40 C, 20% 95% relative humidity kpa ( mbar) atmospheric pressure Rack Max. number Nominal tube Tube length of tubes diameter 12 mm mm mm 18 mm mm mm 30 mm mm mm Frac-920 Physical data Event mark 0.2 sec for both contact closure and TTL output in remote socket Protection class IP 22 Wetted materials PTFE (polytetrafluoroethylene) ECTFE (ethylenechlorotrifluoroethylene) Chemical resistance The wetted parts of the flow diversion valve, the bowl and the racks are resistant to organic solvents and salt buffers commonly used in chromatography of biomolecules, except 100% ethylacetate, 100% hexane and 100% tetrahydrofuran (THF) Power requirement V AC, Hz Power consumption 20 VA Dimensions mm (H W D) Weight 4.5 kg Safety standard This meets the requirements of the Low Voltage Directive 73/23/EEC through the following harmonized standards: EN IEC CAN/CSA-C22.2 No UL EMC standards This device meets the requirements of theemc Directive 89/336/EEC through the following harmonized standards: EN (emission and immunity) EN 55011, GR 2, Class A (emission) This device complies with part 15 of the FCC rules (emission). Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference recevide, including interference that may cause undesired operation. Frac-920 Ordering information Item Quantity Code no. per pack Fraction Collector Frac-920 complete with 18 mm tube rack Tube Racks, complete with bowl, tube support, holder and guide 12 mm mm mm Tube support Tube holder kit Tube spring, metal* Bowl Eppendorf tube holder for 12 mm rack Flow Diversion Valve, SV Tubing holder Funnel Funnel tubing 12/8, 250 mm Drive sleeve Mains distribution cable, 1 m Mains cable, US, 110 V~, 1 m Mains cable, EU, 220 V~, 1 m Remote control cable Event mark/ Signal cable Recorder/UV cable UniNet cable, 1.5 m Teflon tubing, i.d. 1/8, o.d. 3/16" 3 m Tubing connector for 3/16" o.d. tubing Ferrule for 3/16" tubing Stop plug, 5/16" Stop plug, 1/16" Union Luer female/1/16" male Union 1/16" female/m6 male Union M6 female/1/16" male PEEK tubing, i.d mm, o.d. 1/16" 2 m Teflon tubing, i.d mm, o.d. 1/16" 2 m PEEK tubing, i.d. 1.0 mm, o.d. 1/16" 2 m Fingertight connector 1/16" * Only for Tube rack 18 mm AE 5
6 For local office contact information, visit GE Healthcare Bio-Sciences AB Björkgatan Uppsala Sweden imagination at work GE, imagination at work, and GE monogram are trademarks of General Electric Company. ÄKTA, ÄKTAexplorer, ÄKTAfplc, ÄKTAmicro, ÄKTApurifier and UNICORN are trademarks of GE Healthcare companies. All third party trademarks are the property of their respective owners General Electric Company All rights reserved. First published May 2001 All goods and services are sold subject to the terms and conditions of sale of the company within GE Healthcare which supplies them. A copy of these terms and conditions is available on request. Contact your local GE Healthcare representative for the most current information. GE Healthcare UK Limited, Amersham Place, Little Chalfont, Buckinghamshire, HP7 9NA UK GE Healthcare Europe, GmbH Munzinger Strasse 5, D Freiburg Germany GE Healthcare Bio-Sciences Corp. 800 Centennial Avenue, P.O. Box 1327, Piscataway, NJ USA GE Healthcare Bio-Sciences KK Sanken Bldg., , Hyakunincho, Shinjuku-ku, Tokyo Japan AE 06/2009
GE Healthcare. Valve INV-907. Instructions ÄKTA
GE Healthcare Valve INV-907 Instructions ÄKTA Important user information All users must read this entire manual to fully understand the safe use of Valve INV-907. WARNING! CAUTION! Note CE Certifying
More informationValve INV-907. Instructions. 1 Introduction. 2 Installation. Safety. Unpacking. Installing the valve
Instructions 1 Introduction is a motorised rotary 7 port valve. The valve is used in ÄKTA design chromatography systems. It is powered from the ÄKTAdesign P-900 series system pump, and is controlled from
More informationAKTA pure 25 New Owner s Intro
AKTA pure 25 New Owner s Intro The exercise below will give a quick demonstration of how easy and intuitive the AKTA pure 25 will be for you in demonstrating downstream processing to your students. Steps
More informationMODEL 2128 FRACTION COLLECTOR
Threshold Next tube 2 7 8 9 4 5 6 1 2 3 MODEL 2128 FRACTION COLLECTOR Draining ADV COLL STOP HELP CE 0. MODEL 2128 FRACTION COLLECTOR INSTRUCTION MANUAL Catalog Numbers 731-8123 731-8124 Table of Contents
More informationCustomer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation
More informationManual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany
Manual Degasser DDG-75 April 2007 1 Manual Online Degasser DDG-75 DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE-68766 Hockenheim Germany Tel. +49-6205-9450-0 Fax. +49-6205-9450-33 email info@duratec.com
More informationSetting a New Standard in Flash Chromatography Performance
Setting a New Standard in Flash Chromatography Performance What s New Faster Flow rates, up to 300 ml/min Higher pressures, up to 300 psi (20 bar) Bigger touchscreen, 12 or 15 inches Wider Dynamic Range
More informationPreparation of a new hollow fiber cartridge
GE Healthcare Technical Brief 18-1168-00 AB Cross flow filtration Preparation of a new hollow fiber cartridge Preparing a cartridge for use A new ultrafiltration (UF) cartridge must be flushed with water
More informationThermo Scientific Chromatography Well Plates
Thermo Scientific Chromatography Well Plates High-throughput sample handling solutions Well Plates for Chromatography A full selection of high quality sample well plates for your UHPLC, LC and GC applications.
More informationThermo Scientific Chromatography Well Plates
Thermo Scientific Chromatography Well Plates High-throughput sample handling solutions Well Plates for Chromatography A full selection of high quality sample well plates for your UHPLC, LC and GC applications.
More informationVIAFLO 96. Electronic 96 Channel Hand Held Pipettor
VIAFLO 96 Electronic 96 Channel Hand Held Pipettor VIAFLO 96 Unique Multichannel microplate pipetting is a growing task because of the need to increase productivity and improve the quality of the data
More informationThe instrument will process the samples one by one till all the samples have been cleaned up.
Table of Contents SPE-01 Cleanup Station... 1 LC-04SP Valve System... 5 LC-04SP Standalone Valve... 10 LC-05 Auto Injector... 12 LC-06 Dosing Pump... 16 LC-08 Column Selector... 17 SPE-01 Cleanup Station
More informationBenefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations
OXYBABY 6.0 for O 2 or O 2 /CO 2 Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and
More informationBETTER SAMPLE CARE. Spark Holland introduces. SPH1299 UHPLC Gradient Pump
BETTER SAMPLE CARE Spark Holland introduces SPH1299 UHPLC Gradient Pump SPH1299 Spark Holland introduces SPH1299 UHPLC Gradient Pump Robust, Precise and Easy to use Innovative pumping technology created
More informationMV5: Automated concentration system
MV5: Automated concentration system Abstract LabTech MV5 is the latest automatic nitrogen evaporator developed by our R&D Team able to process up to 54 samples simultaneously. This advanced instrument
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationEasy with a modular concept for future expansion
AVS 37 ViscoSystem AVS 370 makes maximum precision... Well equipped for every viscosity determination With the ViscoSystem AVS 370 we have created a measuring device, which not only measures as precisely
More informationUP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule
One Piece or Two? A one-piece fitting is more convenient and less cumbersome, since the ferrule cannot stick in a receiving port and the fitting is more easily found if dropped. With two-piece Fingertight,
More informationGradiFrac. User Manual Edition AF
G E H E A L T H C A R E GradiFrac User Manual 56-1006-08 Edition AF Important user information Reading this entire manual is recommended for full understanding of the use of this product. w The exclamation
More informationPPC4E Pressure Controller/Calibrator Superior rangeability and reliability
PPC4E Pressure Controller/Calibrator Superior rangeability and reliability Technical Data ± 0.02 % of AutoRanged spans from ± 1 kpa (0.15 psi) to 14 MPa (2,000 psi) The Fluke Calibration PPC4E brings high
More information973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS
Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental
More informationHI 2314 HI 2315 HI 23151
Instruction Manual HI 2314 HI 2315 HI 23151 Multi-Range Conductivity Meters for Laboratories www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
More informationLaboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.
Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions
More informationFAST EVAPORATION AT NORMAL PRESSURE
FAST EVAPORATION AT NORMAL PRESSURE FAST EVAPORATION BY BLOWING-DOWN... The VAPORNADO Plus blow-down system is an innovative and efficient instrument for the evaporation of samples and fractions at normal
More informationÄKTAprime. User Manual
User Manual 18-1135-24 Important user information! Meaning: Consult the instruction manual to avoid personal injury or damage to the product or other equipment. WARNING! The Warning sign is used to call
More informationEC214 EC215 - EC215R Bench Conductivity Meters
Instruction Manual EC214 EC215 - EC215R Bench Conductivity Meters http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationTransferpette. Lightweight precise rugged reliable!
Lightweight precise rugged reliable! Transferpette Solutions for S cience F I R S T C L A S S B R A N D The Transferpette S microliter pipettes provide all features required for pipetting in Life Science
More informationAKTA MC SOP Page 1 9/27/04 AKTA METAL CHELATING SOP
AKTA MC SOP Page 1 9/27/04 Date: 9/27/04 Author: A DeGiovanni Edited by: R Kim Reviewed by: Y. Lou AKTA METAL CHELATING SOP Materials/Reagents/Equipment Vendor 1. Water + 0.05% sodium azide 2. 0.2 um filtered
More informationTransferpette. Lightweight precise rugged reliable!
Lightweight precise rugged reliable! Transferpette Solutions for S cience F I R S T C L A S S B R A N D The Transferpette S microliter pipettes provide all features required for pipetting in Life Science
More informationAKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:
1 AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by: Materials/Reagents/Equipment Vendor 1. 0.2 um filtered Water + 0.05% sodium azide 2. 0.2 um filtered
More informationAKTA 3D SOP. Click on the System Control tab. This screen has 4 windows.
AKTA 3D SOP Page 1 9/09/04 Date: 9/09/04 Author: A DeGiovanni Reviewed by: Y. Lou AKTA 3D SOP Materials/Reagents/Equipment Vendor 1. 0.2 um filtered Water + 0.05% sodium azide 2. 0.2 um filtered buffers
More informationUsed with Dissolution Tester for Fraction and Flow Measurements
TOYAMA Auto Sampler W, Model PAS-615 Used with Dissolution Tester for Fraction and Flow Measurements This is a full automatic sampler to be used with 6-shaft or 8-shaft dissolution tester, with the following
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option
ABB MEASUREMENT & ANALYTICS DATA SHEET AP100 ph/redox (ORP) cartridge sensors with water-wash option 2 AP100 P H / R EDOX ( ORP ) CART RI D GE SE NSORS WITH WATE R-WASH OPTION DS/AP100-E N RE V. K Measurement
More informationASSE International Product (Seal) Listing Program
ASSE International Product (Seal) Listing Program ASSE 1070-2015 / ASME A112.1070-2015 / CSA B125.70-15 Performance Requirements for Water Temperature Limiting Devices Manufacturer: Contact Person: E-mail:
More informationKeep the balance in sight
Keep the balance in sight FLUID CONTROL 2225 Suction and irrigation pump for gynecology, urology and surgery FLUID CONTROL 2225 One pump. Three specialisms. No license fees. The new FLUID CONTROL 2225
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationWHEATON. Peristaltic Pumps. Advancing the Science of Liquid Handling
WHEATON Peristaltic Pumps Advancing the Science of Liquid Handling WHEATON Peristaltic Pumps Advancing the Science of Liquid Handling Highly intuitive Icon Driven User Interface enables fast, easy setup
More informationLaboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.
Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography
More informationMinipuls evolution fitted with three 4-channel Medium Flow pump heads. one 4-channel Medium Flow pump head and one 2-channel High Flow pump head
The Minipuls evolution offers enhanced performances for applications such as : > Perfusion chamber > Bioreactor feeding > Purification column > Animal perfusion > LPLC > Media filling > Transfer of viscous,
More information2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version
2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for
More informationGAS ANALYSER OXYBABY M+ for O 2. or O 2 /CO 2. standard version
GAS ANALYSER OXYBABY M+ for O 2 or O 2 standard version Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationCustomer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist
Thank you for purchasing an Agilent system. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is
More informationProudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Varian 310 310 LC/MS Manual System INCLUDES: 310-MS LC/MS triple quadrople
More informationGAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2
GAS ANALYSER OXYBABY 6.0 for or Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and accurate
More informationFor that reason VICI Jour developed:
VICI Jour Safety VICI Safety Products VICI Safety Products NEW VICI strives to provide customers with the best solutions for their problems to make the work better and/or easier, with respect to environment
More informationATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE
ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in
More informationOil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e
Oil Diagnostic Systems Online and bottle measurement Mobile and stationary operation Lab quality accuracy 100.90-1e The new generation of oil diagnostics Mobile and stationary operation: Compressed air
More informationYour local gas generation partner. Precision series Modular gas generation solution for GC.
Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,
More informationOXYBABY - MOBILE HAND HELD GAS ANALYSER
S Application: - Food Packing - Beverage Industry - Cutting & Welding - Hospital and Medical Centre - Laboratory - MOBILE HAND HELD GAS ANALYSER Made in Germany Product of 6.0 for O2 or O2/CO2 premium
More informationFiltration FILTRATION PRODUCT TIPS
Filtration 195 18 Proved and tested, durable, optimally resistant against acids, caustic solutions and other aggressive chemicals: our solutions for efficient and safe filtration. PRODUCT TIPS BOLA Filtration
More informationPeak Biotech - Company & Product Presentation
Peak Biotech - Company & Product Presentation July 2005 Peak Biotech Company & Product Presentation Peak Biotech Company Profile Location Jacob Nøhr Peak Biotech A/S was founded Kvistgaard, Denmark QA
More informationYour local gas generation partner. Precision series Modular gas generation solution for GC.
Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More information215 Liquid Handler Up-Grade Manual
BRUKER NMR 220 25 Liquid Handler Up-Grade Manual For Up-Grade to Run with XWINNMR Vers.. Manual # H977 The kit will include: H9770 BEST NMR Up-Grade Kit to No. Article Bruker # Comment 500mm Capillary
More informationCustomer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist
Agilent Site Preparation Infinity II Checklist Preparative HPLC System Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer
More informationYour local gas generation partner. Precision series Modular gas generation solution for GC.
Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,
More informationAutocalibration Systems for In Situ Oxygen Analyzers
Product Data Sheet PDS 106-340AC.A01 February, 2006 SPS 4001B, IMPS 4000 and MPS 3000 Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationUser Manual. Quantos Automated Dosing Liquid Module
User Manual Quantos Automated Dosing Liquid Module Overview Liquid module 4 2 1 3 5 6 7 Legend Liquid Module Pump module with bottle Liquid kit with liquid dosing head 1 Pump module (QL2) 4 Top glass
More informationKEG PUMP. Range of Electric Keg Pumps
KP KEG PUMP Range of Electric Keg Pumps Electric Keg (Drum) Pumps for Grease KEG PUMP Versatile range of Interlube electric grease pumps for industrial and off-road applications The KP keg pump is available
More informationUser Manual. Quantos Automated Dosing Liquid Module
User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if
More informationAccurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display:
Elcometer 2300 Rotational Viscometers The Elcometer 2300 range of rotational viscometers measures the viscosity of liquids in accordance with several standards. Using a rotational viscometer, the properties
More informationGear Pumps NOTE. 110 LABORATORY PUMPS Gear Pumps. Pulsefree Pumping. Low Operation Costs. The Magnetically Coupled Drive Principle.
Pompe à engrenage ISMATEC IDEX IMLAB - Gear pump ISMATEC IDEX IMLAB 110 LABORATORY PUMPS Gear Pumps Gear Pumps Pulsefree Pumping Gear pumps allow differential pressures up to max. 5.6 bar (81 psi) Low
More informationHigh-Throughput. Faster, Better 96 & 384-Well Pipetting Ultra Efficient and Extremely Versatile
High-Throughput Rainin BenchSmart 96 Automated Aspiration/Dispense Multi-dispense Interchangeable Heads Four Trays, Small Footprint Outstanding Speed & Versatility Faster, Better 96 & 384-Well Pipetting
More informationCONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES
I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationDatasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code)
Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code) ENGLISH Duplex (2-channel) standard connector that accepts solid, round plug pins Bodies supplied
More informationE2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information
Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.
More informationIndustrial pressure controller Model CPC4000
Calibration technology Industrial pressure controller Model CPC4000 WIKA data sheet CT 27.40 Applications Oil and gas industry Industry (laboratory, workshop and production) Transmitter and pressure gauge
More informationAccurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:
Elcometer 2300 Rotational Viscometers The Elcometer 2300 range of rotational viscometers measures the viscosity of liquids in accordance with several standards. Using a rotational viscometer, the properties
More informationEquipment and Accessories. ROMIL LiQuiSure. Designed for High Purity Containment & Dispensing PURE CHEMISTRY
Designed for High Purity Containment & Dispensing To maintain the high purity of ROMIL products during use and handling, we have developed a special range of equipment and accessories under the LiQuiSure
More informationIEC Thermocouple Extension Leads with Miniature or Standard Thermocouple Connectors - Available in types K, J, T & N
Datasheet ENGLISH IEC Thermocouple Extension Leads with Miniature or Standard Thermocouple Connectors - Available in types K, J, T & N (Note: Illustration shows Type T with standard connectors and Type
More informationMobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)
Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium
More informationUser s Guide. Vacuum Controller for liquid delivery systems
Flow Control User s Guide Vacuum Controller for liquid delivery systems Precise Vacuum Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery
More informationIndustrial pressure controller Model CPC4000
Calibration technology Industrial pressure controller Model CPC4000 WIKA data sheet CT 27.40 Applications Oil and gas industry Industry (laboratory, workshop and production) Transmitter and pressure gauge
More informationSolenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners
7 634 VGS1... with AGA67 connector VGS2... with AGA67 connector Solenoid gas valve VGS The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners The VGS and
More informationGasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 055 D01 Two stage operating mode G-(LEP)Z 055 D01 3.0 Printed in Germany Edition 05.11 Nr.
More informationOld documentation - Only for your information! Product is not available any more!
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 055 D01 Two stage operating mode G-(LEP)Z 055 D01 3.0 Printed in Germany Edition 05.11 Nr.
More informationDatasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code)
Datasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code) ENGLISH Thermocouple types K & T to ANSI MC96.1 Fast response, welded exposed junction 1, 2, 5 or 10-metre-long Teflon PFA
More informationINTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,
1 INTRODUCTION Quantum Technology is a leading scientific equipment supplier. For the last thirty years we served our customers by tailoring our products to each customer s unique requirements. Quantum
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationSM Models Manual Control
SM Models Manual Control Practical Choice for Solenoid-driven Pumps Models for chemical injection, high-pressure boiler feed, and outgassing fluids. Temperatures ranges (ambient and transferring liquid)
More informationMULTICHANNEL. Labnet International, Inc.
Labnet International, Inc. A B A1 A2 C F D H E 4A 4B 4C 4D G CONTENTS 1 - INTRODUCTION 2 - VOLUME SETTING 3 - METHOD OF PIPETTING 4 - RECOMMENDATIONS - RECALIBRATION 6 - CLEANING AND STERYLIZATION 7 -
More informationDataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified
DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument
More information16 Ideal for standard laboratory chromatography. 19 High temperature columns ideal for flow chemistry
Omnifit Labware 2 CONTENTS Solvent Safety Bottle Caps 4 Bottle Caps Selection Guide Q-Series Solvent Bottle Caps 6 1/4"-28 UNF threaded inlet lines with optional on-off valves T-Series Solvent Bottle Caps
More informationXMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:
XMO2 Panametrics Smart Oxygen Analyzer Applications An oxygen transmitter for use in: Inerting/blanketing liquid storage tanks Reactor feed gases Centrifuge gases Catalyst regeneration Solvent recovery
More informationDatasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code
Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code ENGLISH These quick connect versions allow rapid termination Miniature connector
More informationINSTRUCTION MANUAL FOR. Chlorinator M 3600 C Controlmatik ABW
INSTRUCTION MANUAL FOR Chlorinator M 3600 C 2014 Controlmatik ABW 1 CONTENTS 1. General... 3 2. Operation... 4 2.1 Automatic control... 6 2.2 Manual control - 1... 6 2.3 Manual control - 2... 6 3. Motor
More informationMV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:
MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve
More informationHigh precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment
Fluid dose dispensing valve High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment Provides the high productivity, stability, reliability,
More informationSanitizers. Sanitizers. Sanitizers for Pools & Spas
Sanitizers Sanitizers for Pools & Spas 213 213 IntelliChlor Salt Chlorinator Featured Highlights IntelliChlor Salt Chlorinator IntelliChlor Salt Chlorinator uses common table salt to produce all the chlorine
More informationUsing the Akta Prime plus October 22, 2012
Some starting precautions: 1. Vacuum filter all buffers. Removes any large particles/debris that may clog your column De-gases the buffers 2. Clarify lysates first by centrifugation and then filtration
More informationENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug
ENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug Thermocouple types K, J & T Fast response, welded exposed junction 1, 2, 5 or 10 metre lengths available Teflon
More informationGas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation
Gas Clean Filters Delivering Clean Gases for GC and GC/MS Operation Gas Clean Filters Fast, leak-free replacement without tools! Each Gas Clean Filter features a unique quick disconnect design which allows
More informationSF 6 Product Guide. Gas Analysis Instruments and Accessories
SF 6 Product Guide Gas Analysis Instruments and Accessories Cambridge Sensotec Ltd specialises in the design and manufacture of gas analysis equipment under the Rapidox brand name. Based in the UK, the
More informationCONSTANT PRESSURE SYRINGE PUMP
A NEW TECHNOLOGY BREAKTHROUGH CONSTANT PRESSURE SYRINGE PUMP ENABLES CONTINUOUS PRESSURE-CONTROLLED INFUSION USE IN CONSTANT FLOW OR CONSTANT PRESSURE MODE ENHANCES SAFETY FOR SENSITIVE EXPERIMENTATION
More information