Pro-V Multivariable Flowmeter Model M22 In-line Vortex
|
|
- Eugenia Randall
- 5 years ago
- Views:
Transcription
1 Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, Multivariable meter delivers mass flow, temperature, pressure, and density readings from a single installed device and reduces initial cost, installation cost and cost-of ownership over the lifetime of the instrument Mass flow equations - real gas, ideal gas, AGA 8, API 2540 Compensated mass flow reading of liquids, Energy Monitoring ability to compute and output energy use Easy to install and commission Reliable no moving parts, no fluid to sensor contact High accuracy with rangeability up to 100:1 Temperature up to 750 F Pressure up to 1500 psig Inline configuraton for pipes from 1/2-12 DN15 to DN 300 Field configurable ranges, outputs and displays Remote electronics option available for use in harsh environments or locations with limited access VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an RTD temperature sensor, and a solid-state pressure transducer to measure the mass flow rate of gases, liquids and steam. Systems that use external process measurements to calculate mass flow may not provide adequate compensation for the fact that process conditions can change radically between the point of velocity measurement and the point where upstream or downstream pressure and temperature measurements are being made. Because the Pro-V multivariable flowmeter measures all of these parameters in a single location, it delivers a more accurate process measurement. Integrating multivariable output capability with a single line penetration also simplifies system complexity and helps reduce initial equipment cost, installation cost and maintenance costs. The product line is available with a wide range of options and meter configurations to meet your specific application requirements. 4-20mA loop powered Mass Meter design saves on energy costs HART protocol communications - Standard Modbus, BACnet communications available FM, FMC, ATEX, IECEx Approved VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO USA Tel: 303/ Fax: 303/ info@vortekinst.com
2 Pro-V Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics, the frequency at which the vortices are alternately shed is directly proportional to the flow velocity. As flow passes a bluff body in the flow stream, the vortices create low and high pressure zones behind the bluff body, or shedder bar. The Pro-V M22 uses a piezoelectric crystal sensor to detect the pressure exerted by the vortices on the velocity sensor. The piezoelectric converts these pulses into electrical signals. The meter uses an all welded sensor design to create a robust sensor and to minimize potential leakages. VELOCITY SENSOR Performance Specifications A c c u r a c y Mass flow rate accuracy for gas and steam based on % of pressure range. Model M22 Multiparameter Inline Vortex Meter Process Variables Liquids Gas & Steam Volumetric ±.7% of Rate ± 1% of Rate Flow Rate Mass Flow Rate ± 1% of Rate ± 1.5% of Rate Temperature ± 2 F (± 1 C) ± 2 F (± 1 C) Pressure ±.3% of Full Scale ±.3% of Full Scale Density ±.3% of Reading ±.5% of Reading BLUFF BODY VORTICES R e p e a t a b i l i t y Volumetric Flow Rate ±.1% of rate Temperature ±.2 F (±.1 C) Pressure ±.05% of full scale FLOW Pro-V Model M22-VTP The Model M22-VTP offers you flow computer functionality in a compact field device. This multivariable instrument incorporates temperature and pressure sensors to provide an instantaneous reading of the compensated mass flow rate of gases, liquids and steam. In addition to outputs for totalized mass and alarm settings, the field-configurable electronics deliver up to three analog 4-20 ma outputs of five process measurements, including volumetric flow rate, mass flow rate, pressure, temperature and density. Pro-V Model M22-VT The Model M22-VT integrates a precision 1000 Ohm platinum RTD temperature sensor that can be used to calculate and output a compensated mass reading. This device is typically used to measure flow rates of saturated steam. Pro-V Model M22-V The Model M22-V delivers a direct reading of volumetric flow rate generally the most cost-effective solution for liquid flow monitoring -in applications ranging from general water flows to hydrocarbon fuel flow measurement. Pro-V Model M22-EM The Model M22 Energy Monitoring option permits real-time calculation of energy consumption for a facility or process. The meter can be programmed to measure steam, hot water or chilled water. The Model M22-VTP flowmeter monitors one side of the process, either sent or returned, and uses the input from a second separate temperature sensor on the opposite leg of the process to calculate the change in energy. Selectable energy units include Btu, joules, calories, Watt-hours, Megawatt-hours and Horsepower-hours. The local or remote electronics indicate two temperatures, delta T, mass total and energy total. Pro-V Model M22-VTEP, VETEP Similar to M22-VTP but with the option for an external input (T or P) via RTD or 4-20mA or one of each. S t a b i l i t y O v e r 1 2 M o n t h s Volumetric Flow Rate ± negligible Temperature ±.9 F (±.5 C) Pressure ±.1% of full scale R e s p o n s e T i m e Adjustable from 1 to 100 seconds Operating Specifications Any gas, liquid or steam compatible with 316L stainless steel, C276 hastelloy or A105 carbon steel. Not recommended for multi-phase fluids. P r o c e s s a n d A m b i e n t Te m p e r a t u r e Process Standard Temperature (code ST): -330 to 500 F (-200 to 260 C) Process High Temperature (code HT): to 750 F (400 C) Ambient Operating: -40 to 140 F (-40 to 60 C) Ambient Storage: -40 to 185 F (-40 to 85 C) Pressure Transducer Ratings Full Scale Operating Pressure Max. Over-Range Pressure psia bara psia bara VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO USA Tel: 303/ Fax: 303/ info@vortekinst.com
3 Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, Multivariable meter delivers mass flow, temperature, pressure, and density readings from a single installed device and reduces initial cost, installation cost and cost-of ownership over the lifetime of the instrument Mass flow equations - real gas, ideal gas, AGA 8, API 2540 Compensated mass flow reading of liquids, Energy Monitoring ability to compute and output energy use Easy to install and commission Hot tappable, process shut down not required for installation Reliable no moving parts, no fluid to sensor contact High accuracy with rangeability up to 100:1 Temperature up to 750 F Pressure up to 1500 psig Insertion style mounting permits installation in any pipe 2" and greater Field configurable ranges, outputs and displays Remote electronics option available for use in harsh environments or locations with limited access VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an RTD temperature sensor, and a solid-state pressure transducer to measure the mass flow rate of gases, liquids and steam. Because the Pro-V is able to measure all process variables within a single device it provides exceptional accuracy, simplifies system design and reduces installation costs. To enhance reliability, the Pro-V Model M23 insertion flowmeters feature a no-moving parts design and rugged, welded construction. They are easily installed with flanged or Male NPT process connections in any pipe size of two-inches and greater. Optional retractor or hot-tap hardware simplifies maintenance operations. The Pro-V provides excellent rangeability and a low permanent pressure drop. To simplify installation and commissioning, all measured variables and programming menus are available on the instrument s easy to use display and control pad. The product line is available with a wide range of options and meter configurations to meet your specific application requirements. 4-20mA loop powered Mass Meter design saves on energy costs HART protocol communications - Standard Modbus, BACnet communications available FM, FMC, ATEX, IECEx Approved VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO USA Tel: 303/ Fax: 303/ info@vortekinst.com
4 Pro-V Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics, the frequency at which the vortices are alternately shed is directly proportional to the flow velocity. Insertion vortex flowmeters measure flow by detecting the local velocity at a strategically located position within the pipe. The Pro-V M23 detects the frequency at which vortices are alternately shed from the bluff body located within the sensor head. The Pro-V M23 uses the local velocity, along with other parameters, such as fluid type, pipe size and Reynolds number to calculate the average pipe velocity, and consequently, the volumetric flow rate. Performance Specifications A c c u r a c y Mass flow rate accuracy for gas and steam based on % of pressure range. Pro-V Model M23 Multivariable Flowmeter Process Variables Liquids Gas & Steam Volumetric ± 1.2% of Rate ± 1.5% of Rate Flow Rate Mass Flow Rate ± 1.5% of Rate ± 2.0% of Rate Temperature ± 2 F (± 1 C) ± 2 F (± 1 C) Pressure ±.3% of Full Scale ±.3% of Full Scale Density ±.3% of Reading ±.5% of Reading R e p e a t a b i l i t y Volumetric Flow Rate ±.1% of rate Temperature ±.2 F (±.1 C) Pressure ±.05% of full scale S t a b i l i t y O v e r 1 2 M o n t h s Volumetric Flow Rate ± negligible Temperature ±.9 F (±.5 C) Pressure ±.1% of full scale Pro-V Model M23-VTP The Model M23-VTP offers you flow computer functionality in a compact field device. This multivariable instrument incorporates temperature and pressure sensors to provide an instantaneous reading of the compensated mass flow rate of gases, liquids and steam. In addition to outputs for totalized mass and alarm settings, the field-configurable electronics deliver up to three analog 4-20 ma outputs of five process measurements, including volumetric flow rate, mass flow rate, pressure, temperature and density. Pro-V Model M23-VT The Model M23-VT integrates a precision 1000 Ohm platinum RTD temperature sensor that can be used to calculate and output a compensated mass reading. This device is typically used to measure flow rates of saturated steam. Pro-V Model M23-V The Model M23-V delivers a direct reading of volumetric flow rate -generally the most cost-effective solution for liquid flow monitoring in applications ranging from general water flows to hydrocarbon fuel flow measurement. Pro-V Model M23-EM The Model M23 Energy Monitoring option permits real-time calculation of energy consumption for a facility or process. The meter can be programmed to measure steam, hot water or chilled water. The Model M23-VTP flowmeter monitors one side of the process, either sent or returned, and uses the input from a second separate temperature sensor on the opposite leg of the process to calculate the change in energy. Selectable energy units include Btu, joules, calories, Watt-hours, Megawatt-hours and Horsepower-hours. The local or remote electronics indicate two temperatures, delta T, mass total and energy total. Pro-V Model M23-VTEP, VETEP Similar to M23-VTP but with the option for an external input (T or P) via RTD or 4-20mA or one of each. R e s p o n s e T i m e Adjustable from 1 to 100 seconds Operating Specifications Any gas, liquid or steam compatible with 316L stainless steel. Not recommended for multi-phase fluids. P r o c e s s a n d A m b i e n t Te m p e r a t u r e Process Standard Temperature (code ST): -330 to 500 F (-200 to 260 C) Process High Temperature (code HT): to 750 F (400 C) Ambient Operating: -40 to 140 F (-40 to 60 C) Ambient Storage: -40 to 185 F (-40 to 85 C) Pressure Transducer Ratings Full Scale Operating Pressure Max. Over-Range Pressure psia bara psia bara VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO USA Tel: 303/ Fax: 303/ info@vortekinst.com
5 Turbo Pro Multivariable Flowmeter Model Pro-T Insertion Turbine Mass Flow Meter Pro-T TM Advantage: Volumetric or mass flow monitoring of most liquids, Multivariable meter delivers mass flow, temperature, pressure, and density readings from a single installed device and reduces initial cost, installation cost and cost-of ownership over the lifetime of the instrument Compensated mass flow reading of liquids, Easy to install and commission Hot tappable, process shut down not required for installation High accuracy with rangeability up to 17:1 Temperature -450 to 850 F Pressure up to 1500 psig Insertion style mounting permits installation in any pipe 2" and greater Field configurable ranges, outputs and displays Remote electronics option available for use in harsh environments or locations with limited access 4-20mA loop powered Mass Meter design saves on energy costs HART protocol communications - Standard Modbus, BACnet communications available VorTek Instruments Model Pro-T multivariable flowmeters utilize three primary sensing elements a turbine sensor, an RTD temperature sensor, and a solid-state pressure transducer to measure the mass flow rate of gases, liquids and steam. Because the TurboPro is able to measure all process variables within a single device it provides exceptional accuracy, simplifies system design and reduces installation costs. They are easily installed with flanged or Male NPT process connections in any pipe size of two-inches and greater. Optional retractor or hot-tap hardware simplifies maintenance operations. TurboPro Model Pro-T provides excellent rangeability and can measure very low flow rates with negligible permanent pressure drop. Additionally rotors are interchangeable, making this meter a good choice for installations with step changes in seasonal flow rates. To simplify installation and commissioning, all measured variables and programming menus are available on the instrument s easy to use display and control pad. The product line is available with a wide range of options and meter configurations to meet your specific application requirements. FM, FMC, ATEX, IECEx Approved VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO USA Tel: 303/ Fax: 303/ info@vortekinst.com
6 TurboPro Principle of Operation Insertion turbine flow meters measure flows of liquid, gas, and steam by detecting the frequency of rotation of the turbine blades. According to the proven laws of physics, the frequency at which the turbine rotates is directly proportional to the flow velocity. Insertion turbine flow meters measure flow by detecting the local velocity at a strategically located position within the pipe. The TurboPro TM detects the frequency within the sensor head. It uses the local velocity, along with other parameters such as fluid type, pipe size, and Reynolds Number to calculate the average pipe velocity, and consequently, the volumetric flow rate. Performance Specifications A c c u r a c y Mass flow rate accuracy for gas and steam based on % of pressure range. Turbo Pro Model Pro-T Multivariable Flowmeter Process Variables Liquids Gas & Steam Volumetric Flow Rate ± 1.2% of Rate ± 1.5% of Rate Mass Flow Rate ± 1.5% of Rate ± 2.0% of Rate Temperature ± 2 F (± 1 C) ± 2 F (± 1 C) Pressure ±.3% of Full Scale ±.3% of Full Scale Density ±.3% of Reading ±.5% of Reading R e p e a t a b i l i t y Volumetric Flow Rate ±.1% of rate Temperature ±.2 F (±.1 C) Pressure ±.05% of full scale TurboPro Model Pro-T -VTP The Model Pro-T offers you flow computer functionality in a compact field device. This multivariable instrument incorporates temperature and pressure sensors to provide an instantaneous reading of the compensated mass flow rate of gases, liquids and steam. In addition to outputs for totalized mass and alarm settings, the field-configurable electronics deliver up to three analog 4-20 ma outputs of five process measurements, including volumetric flow rate, mass flow rate, pressure, temperature and density. TurboPro Model Pro-T -VT The Model Pro-T -VT integrates a precision 1000 Ohm platinum RTD temperature sensor that can be used to calculate and output a compensated mass reading. This device is typically used to measure flow rates of saturated steam. TurboPro Model Pro-T -V The Model Pro-T -V delivers a direct reading of volumetric flow rate generally the most cost-effective solution for liquid flow monitoring in applications ranging from general water flows to hydrocarbon fuel flow measurement. TurboPro Model Pro-T -EM The Model Pro-T -EM Energy Monitoring option permits real-time calculation of energy consumption for a facility or process. The meter can be programmed to measure steam, hot water or chilled water. The Model Pro-T -EM flowmeter monitors one side of the process, either sent or returned, and uses the input from a second separate temperature sensor on the opposite leg of the process to calculate the change in energy. Selectable energy units include Btu, joules, calories, Watt-hours, Megawatt-hours and Horsepower-hours. The local or remote electronics indicate two temperatures, delta T, mass total and energy total. TurboPro Model Pro-T -VTEP, VETEP Similar to Pro-T-VTP but with the option for an external input (T or P) via RTD or 4-20mA or one of each S t a b i l i t y O v e r 1 2 M o n t h s Volumetric Flow Rate ± negligible Temperature ±.9 F (±.5 C) Pressure ±.1% of full scale R e s p o n s e T i m e Adjustable from 1 to 100 seconds Operating Specifications Any gas, liquid or steam compatible with 316L stainless steel and other listed wetted materials. Not recommended for multi-phase fluids. P r o c e s s a n d A m b i e n t Te m p e r a t u r e Process Standard Temperature (code ST): -67 to 450 F (-55 to 238 C) Process High Temperature (code HT): -488 to 850 F (-267 to 454 C) Ambient Operating: -40 to 140 F (-40 to 60 C) Ambient Storage: -40 to 185 F (-40 to 85 C) Pressure Transducer Ratings Full Scale Operating Pressure Max. Over-Range Pressure psia bara psia bara VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO USA Tel: 303/ Fax: 303/ info@vortekinst.com
7 M23 Pro-T M O U N T I N G A C C E S S O R I E S VorTek Instruments, LLC 8475 West I-25 Frontage Rd. Suite 300 Longmont, CO USA Tel: 303/ Fax: 303/ info@vortekinst.com
8 Gate Valves Threaded Kits 2" 3000# full coupling 2" X 3 " sch 80 nipple 2" FxF NPT gate Valve H 2" 3000# threaded weld coupling Gate Valves Threated Kits Model Code Max Pressure Max Temperatre Material Class Connection Face to face Centerline to H(if Kit Supplied) top (open) VKBT-125() 200 PSI AT 100F 400 F AT 125 PSI BRONZE 125 THREATED 3.35 [85.1] [295.9] [286.0] VKBT-150() 300 PSI AT 100F 400 F AT 150 PSI BRONZE 150 THREATED 3.88 [98.6] [309.6] [299.5] VKBT-200() 400 PSI AT 100F 550 F AT 200 PSI BRONZE 200 THREATED 3.96 [100.6] [309.6] [301.5] VKBT-300() 1000 PSI AT 100F 550 F AT 300 PSI BRONZE 300 THREATED 3.96 [100.6] [309.6] [301.5] VKCT-800() 1975 PSI AT 100F 750 F AT 1345 PSI CARBON STEEL 800 THREATED 5.62 [142.7] [330.2] [343.7] VKCT-200() 275 PSI AT 100F 350 F AT 200 PSI STAINLESS STEEL 200 THREATED 3.74 [95.0] 7.44 [189.0] [295.9] VKST-800() 1920 PSI AT 100F 1123 F AT 800 PSI STAINLESS STEEL 800 THREATED 5.25 [133.4] [285.8] [334.3] (Specify pipe OD in inches in parenthesis) Flanged Gate Valves Centerline to top (open) Face to Face Flanged Gate Valves Model Code Max Pressure Max Temperature Material Class Connection Face to face Centerline to top (open) VACF PSI AT 100F 750F AT 95 PSI CARBON STEEL 150 FLANGED 7.00 [177.80] [431.80] VACF PSI AT 100F 750F AT 505 PSI CARBON STEEL 300 FLANGED 8.50 [215.90] [457.20] VACF PSI AT 100F 750F AT 1010 PSI CARBON STEEL 600 FLANGED [292.10] 18.00[457.20] VASF PSI AT 100F 750F AT 95 PSI STAINLESS STEEL 150 FLANGED 7.00 [177.80] [431.80] VASF PSI AT 100F 750F AT 425 PSI STAINLESS STEEL 300 FLANGED 8.50 [215.90] [457.20] VASF PSI AT 100F 750F AT 855 PSI STAINLESS STEEL 600 FLANGED [292.10] [457.20]
9 Flanged Adapters Raised Face Weld Neck Flange 2" Schedule 40 H 1/16 Field Weld Butt-Weld Outlet Fitting 2" 3000# Existing Pipe Flanged Adapters Model Code Material Class Connection H PACF - 150() CARBON STEEL 150 FLANGED 4.00 [101.6] PACF - 300() CARBON STEEL 300 FLANGED 4.25 [107.9] PACF - 600() CARBON STEEL 600 FLANGED 4.62 [117.3] PASF - 150() STAINLESS STEEL 150 FLANGED 4.00 [101.6] PASF - 300() STAINLESS STEEL 300 FLANGED 4.25 [107.9] PASF - 600() STAINLESS STEEL 600 FLANGED 4.62 [117.3] (Specify pipe OD in inches in parenthesis) Pipe Adapters 2" FNPT 1.5" (38.1 mm) Threaded pipe adapter 2" 3000# Existing Pipe Field Weld Pipe Adapters Model Code Material Connection PACT( ) CARBON STEEL THREADED PAST( ) STAINLESS STEEL THREADED (Specify pipe OD in inches in parenthesis)
10 A leader in precision multivariable flowmeters for the measurement of liquid,gas,steam and energy. VorTek Instruments, LLC 8475 West I-25 Frontage Rd., Suite 300 Longmont, CO USA Tel: 303/ Fax: 303/
Pro-V Multivariable Flowmeter Model M22 In-line Vortex
Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationPro-V Multivariable Flowmeter
Pro-V Multivariable Flowmeter Model M23 Insertion Meter M23-V flowmeter provides cost-effective volumetric flow monitoring solution for most liquids M23-VT incorporates temperature sensing to provide a
More informationPanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications
GE Measurement & Control PanaFlow MV82 Insertion Style Multivariable Flowmeter Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using
More informationFor Multi-Parameter Meters see mvx
Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid
More informationFor Multi-Parameter Meters see mvx
VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see mvx Principles of Operation VX No moving parts to wear or fail. Electronics can be remotely mounted up to 30.5 m (0 ft). No fluid
More informationFlow and Energy Measurement F-5400 THERMAL MASS FLOW METER
THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air
More informationVortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas
Vortex Flow Meter Wafer or Flange Connection - Steam - Liquid - Gas Working Principle & Circuit Diagram Working Principle When a column body placed in flowing fluids in pipe, a series of vortices will
More informationVortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features
Vortex flowmeters introduction Product review s Key product features This document should not be duplicated, used, distributed, or disclosed for any purpose unless authorized by Siemens. Page 1 Vortex
More informationOver 20,000 Strain Gage Target flowmeters installed since 1952.
Over 20,000 Strain Gage Target flowmeters installed since 1952. Liquid, gases, superheated and saturated steam from -320 to 500 O F and up to 15,000 psi. No frictional moving parts. Designed to withstand
More informationVortex Meters for Liquids, Gas, and Steam
A Measuring Principle Comes of Age: Vortex Meters for Liquids, Gas, and Steam Dipl.-Hyd. Oliver Seifert, Product Management Vortex Meters at Flowtec AG, and Ellen-Christine Reiff, M.A., Editor s Office,
More informationFlow metering in gases Introduction to COMBIMASS family
Flow metering in gases Introduction to COMBIMASS family - physical principle, basic information - different types of instruments, pricing & delivery time Sales Training Germany October 17 th to 19 th,
More informationVersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.
VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and
More informationLUGB Vortex Flowmeter
LUGB Vortex Flowmeter Overview LUGB swirl flowmeter is also called as vortex flowmeter, it is a new of flowmeter which is developed according to fluid vibration theory, widely used for fluid measurement
More informationCOMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid
Volumetric flow Compressed Air Mass flow Gas Net volumetric flow Steam Liquid Universal compact orifice flow meter combines a compact orifice flow sensor and sotiphicated converter One-piece flow sensor,
More informationTurbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
More informationOnline data sheet FLOWSIC30 GAS FLOW METERS
Online data sheet A B C D E F H I J K L M N O P Q R S T Ordering information LTRASONIC GAS FLOW METER FOR CTION Type Part no. On request The exact device specifications and performance data of the product
More informationT EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions
Technology Solutions T EK-COR 1100A Coriolis Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction There can often be more than one type
More informationVariable Area Flow Meters
Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more
More informationanalytical bulk flow distance FLOW level pressure temperature industrial communication
analytical bulk flow distance level pressure temperature industrial communication isolv THERMAL MASS METER Measuring Principle Self-heated Sensor Reference Sensor isolv Thermal Mass Flow Meters have two
More informationTurbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
More informationTHERMAL MASS FLOW MEASUREMENT FOR GASES
THERMAL MASS MEASUREMENT FOR GASES Make the Wise Choice. Choose Sage Flow Meters. A Commitment to Higher Performance SAGE METERING is a manufacturer of high performance Thermal Mass Flow Meters which measure
More informationDesign Features. General Description
Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design
More informationTurbine Flowmeters for Gas Applications (Metric)
Turbine Flowmeters for Gas pplications (Metric) Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs.
More informationNEW VERSAFLOW CORIOLIS
Steffen Baecker June 20, 2017 NEW VERSAFLOW CORIOLIS With Stable Two-phase Flow Measurement Honeywell Internal VersaFlow Flow Technologies Volume flow measurement Conductive fluids only - Water - Chemicals
More informationTEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions
Technology Solutions TEK-THERMAL 1700B Thermal Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Thermal 1700B Thermal Mass Flowmeters,
More informationTransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features
Applications The TransPort PT878GC clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive
More informationWafer type. the product
. VFM5 Vortex Flow Meter Flanged type Wafer type Insertion type VFM5 is a powerful flow meter utilizing Karman vortex theory, which can meet the requirement of measuring the flow rate of various fluids
More informationBrooks TMF-Zone 1 Models 5816-Ex/5864-Ex
Data Sheet DS-TMF-586Ex-MFC-eng TMF-Zone Brooks TMF-Zone Models 586-Ex/5864-Ex Customer Benefits Assured process accuracy and repeatability Long-term reliability Reduced maintenance CE certified Improved
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationInstructions for SMV 3000 Multivariable Configuration (MC) Data Sheets
Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets Similar to the TC option for ST 3000 transmitters, the MC option for the SMV 3000 provides a service to our customers which results
More informationONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems
ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems 1322 Foxwood, Houston, Texas 77008 INTRODUCTION With the increased use of Natural Gas as a fuel, higher natural gas prices,
More informationPrecision Mass Flow Meters / Controllers for Liquids and Gases
CORI-FLOW TM Precision Mass Flow Meters / Controllers for Liquids and Gases Introduction Bronkhorst Cori-Tech B.V. manufactures precise, compact Mass Flow Meters and Controllers for gases and liquids,
More informationTransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications
Applications The TransPort PT878GC clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive
More informationONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction
ONSITE PROVING OF GAS METERS Daniel J. Rudroff WFMS Inc. 13901 West Bellfort Sugar Land, Texas Introduction With the increased use of Natural Gas as a fuel, and higher natural gas prices buyers and sellers
More informationdeltaflowc deltaflowc Venturi or Probe
deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc
More informationDifferential Pressure Transmiter
Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;
More informationFeatures. Description
Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter
More informationHow to specify a product. Process Sensors and Mechanical Instruments
How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification
More information780S Ultra High Purity Series
Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board
More informationDigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range
DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range Applications The DigitalFlow GF868 flowmeter is a complete ultrasonic flow metering system for: Flare gas
More informationFlowatch Multiphase Flow Meter
Multiphase Flow Meter Multiphase Flow Meter Key Components Pietro Fiorentini's FLOWATCH is a non-intrusive, non radioactive, in-line multiphase meter for measuring flow rates of oil, water and gas from
More informationGFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features
Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma
More informationThe M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions
The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly
More informationPorter Analytical & Industrial Products
Porter Analytical & Industrial Products Porter Analytical & Industrial Products Engineered to Excel in Critical Applications The Porter Instrument Division of Parker Hannifin Corporation is a leading manufacturer
More informationFlow Measurement SITRANS F X
Overview Using a vortex flowmeter with integrated pressure and temperature compensation such as the allows you not only to lower installation costs but also increase the measuring accuracy of the measuring
More informationIntegral type Differential pressure flowmeter VNT Series
Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.
More informationCORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES
SENSORS FOR MASS FLOW AND PRESSURE CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES INTRODUCTION Bronkhorst High-Tech BV is the worldwide pioneer in the field of low flow liquid metering
More informationMicro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001188, Rev. B April 2009 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
More informationFlow Measurement SITRANS F X
SITRANS FX00 Overview The main applications of SITRANS FX00 can be found in the following sectors: Chemical Petrochemical Oil & Gas Power plants -Air - Heating - Cooling -Chilling Food & beverage - Pharmaceutical
More informationTechnical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter
Technical Data Sheet KROHNE 12/2004 7.02516.21.00 CH/GR OPTIMASS 7000 Custody Transfer Mass Flowmeter with single straight measuring tube OIML R117 Pattern Approval Accuracy classes 0.3 / 0.5 / 1.0 / 1.5
More informationPorter Lab & Analytical Products
Porter Lab & Analytical Products Porter Lab & Analytical Products Engineered to Excel in Critical Applications The Porter Instrument Division of Parker Hannifin Corporation is a leading manufacturer of
More informationExcellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA
Excellent Vortex meter INSERTION Type BATTERY POWERED EX DELTA GENERAL SPECIFICATION GS.No.GBD604E-6 GENERAL The battery-powered EX DELTA is a dedicated on site monitor with a wide variety of applications
More informationX-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司
X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or
More informationApplications. Features AWWA ULTRASONIC WATER METER
MEASURE TODAY. ENSURE TOMORROW wprime Series 280W-D Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential
More informationSFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:
SKYLINE FLOW CONTROLS INC. SFC Skyline Flow Controls Wedge Meter (SFC-WM) The SFC wedge meter is a differential pressure device for use on all fluids. It is especially designed for slurries and liquids
More informationTorque Tube TB300 Digital Transmitters
Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional
More informationRTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features
GE Measurement & Control RTX 1000H Series Versatile Transmitters for a World of Pressure GE Measurement & Control is renowned for the design and manufacture of compact and rugged high performance pressure
More informationCLARK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe Sizes, Rugged Molded PPA Construction
www.clarksol.com LRK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe s, Rugged Molded PP onstruction DESRIPTION The series 200 vortex flow transmitters are designed with equipment
More informationVarea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids
Varea-Meter Flowmeters For Metering and Controlling Flows of Process Fluids Product Descriptions Our broad line of rotametertype flowmeters provides reliable readout, transmission, and control of liquids
More informationTransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Sensing. Applications. Features
Applications The TransPort PT878GC clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive
More informationdeltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type
deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp-, p- and T-Sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Gas Massflowmeter Venturi- and Probe Type Precise
More informationA review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility
A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility mass balance and compliance 1. What, When and Why? 2. Flare
More informationPressure and/or Temperature Pilot Operated Steam Regulators Series 2000
Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They
More informationDigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter. GE Sensing. Features. Applications
Applications Features The DigitalFlow GF868 flowmeter is a complete ultrasonic flow metering system for: Flare gas Track down or prevent losses from leakage with positive material identification Account
More informationGas Measurement Fundamentals Certification. Curriculum
Gas Certification Institute, LLC P.O. Box 131525 Houston, Texas 77219-1525 281-598-7200 Phone 281-598-7199 Fax contact@gascertification.com www.gascertification.com Curriculum Copyright 2007-2012 Gas Certification
More informationNo E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.
No. 2000-03E Averaging Pitot Tube Flow Sensor HITROL CO., LTD. M e a s u r e m e n t Pr i n c i p l e Measurement principle of Hitbar sensor is explained below. When a Hitbar is installed in the pipeline
More informationLevel, Pressure, and Density Instrumentation for the Petrochemical Industry
Level, Pressure, and Density Instrumentation for the Petrochemical Industry Application Examples and Products Measurement technology for the petrochemical industry This brochure presents examples of applied
More informationGP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI
GP1 & GP2 Electropneumatic Regulators FOR PRESSURE CONTROL TO 1, PSI GP1 & GP2 Functional Description The GP series control valve is an electronic pressure regulator designed to precisely control the pressure
More informationTF- & DM-Series. Turbineflowmeter
Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation
More informationTruck-mounted Mass Flow Metering for LPG Delivery
Truck-mounted Mass Flow Metering for LPG Delivery Itron, Inc. 1310 Emerald Rd. Greenwood, SC 29646 Introduction The mathematician Gustave De Coriolis first described the Coriolis Effect, which is an inertial
More informationSteel-Mass Model 640S
Smart Insertion Thermal Gas Mass Flow Meter Features Direct mass flow monitoring eliminates need for seperate temperature and pressure inputs Accuracy +/- 1% of reading plus 0.5% of full scale Patented
More informationTRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.
TRZ 0-K Volumeter TRZ 0-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Turbine Gas Flowmeter continues the tradition of Honeywell s field-proven turbine meter technology, delivering
More informationMultiphase MixMeter. MixMeter specification. System Specification. Introduction
System Specification Multiphase MixMeter Introduction The MixMeter is unique in applying proper homogenization techniques to multiphase measurement. In so doing the MixMeter avoids the requirement for
More informationRCD - Ultra-Rugged Differential Pressure Flowmeter
0.15-1 to 85-600 GPM Liquids 2.5-25 to 300-1700 SCFM Gases 1/2 to 3 Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available Custom Calibrations
More informationT EK-COR 1100A Coriolis Mass Flowmeter
T EK-COR 1100A Coriolis Mass Flowmeter Instruction Manual Document Number: IM-1100A NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance,
More informationMicro Motion 7835 Series Density and Concentration Meters
Product Data Sheet PS-001039, Rev. J January 2011 Micro Motion 7835 Series Density and Concentration Meters Micro Motion density and concentration meters are built to tackle the most demanding process
More informationAFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features
ANALOG MASS FLOW CONTROLLERS Model AF mass fl ow controllers are designed to indicate fl ow rates and control set fl ow rates of gases. Each of these units incorporates an advanced straight tube sensor
More informationERZ 2000-NG Flow Computer
ERZ 2000-NG Flow Computer With decades of natural gas measurement experience, RMG has developed the ERZ 2000-NG an approved and best-in-class gas flow measurement solution for all areas of gas volume conversion.
More informationTechnical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description
Smart-Trak Model 100 High Performance Digital Gas Mass Flow Meters and Controllers Features Measure & control gas mass flow rates up to 1000 slpm True digital performance provides high accuracy and great
More informationTECHNIQUES OF COMPOSITE SAMPLING. Kris Kimmel. YZ Systems, Inc Pollok Drive Conroe, Texas 77303
TECHNIQUES OF COMPOSITE SAMPLING Kris Kimmel YZ Systems, Inc. 3101 Pollok Drive Conroe, Texas 77303 Introduction Since a gas sampling system can be referred to as a cash register it is very important that
More informationTEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL
Technology Solutions TEK-SUB 4800B Submersible Level Transmitter LEVEL Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Sub 4800B Submersible Level Transmitter
More informationMiniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800
KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationSeries INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN
INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II
More informationFeatures. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)
1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More information2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications
Application Description AG/266PILD-EN Rev. C 2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic Pressure Measurement Engineered solutions for all applications Increase plant productivity
More informationModel FT4X Thermal Mass Flow Meter & Temperature Transmitter
Model FT4X Gas Mass Flow Meter For Oil & Gas, Industrial, and Wastewater Applications 2nd Generation DDC-Sensor : Robust, non-cantilevered design Programmable Contract Time Gas-SelectX : menu of field
More informationRadar, Ultrasonic and RF Level Transmitters
Radar, Ultrasonic and RF Level Transmitters Both measures the time it takes the wave to travel between the transmitter and that reflected wave off the surface of the material to reach the transmitter again.
More informationNon-intrusive Natural Gas Flow Measurement
Non-intrusive Natural Gas Flow Measurement Upstream Midstream Downstream - Gas at the Separator Outlet - Wellhead Gas Flow Measurement - Gas Injection n & Lift - Gas Treatmentent on - Compressor r Stations
More informationDrilling Efficiency Utilizing Coriolis Flow Technology
Session 12: Drilling Efficiency Utilizing Coriolis Flow Technology Clement Cabanayan Emerson Process Management Abstract Continuous, accurate and reliable measurement of drilling fluid volumes and densities
More informationMMS Mercury Monitoring System for Natural Gas
MMS Mercury Monitoring System for Natural Gas Natural gas often contains mercury at concentrations that vary from below 1 to above 10000 µg/m 3. Mercury is both toxic and potentially damaging: it can corrode
More informationMASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS
MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass
More informationElectronic Volume Correctors
Electronic Volume Correctors Ben Manson Landis+Gyr October 14, 2016 PUBLIC Agenda Customer Types and suitable equipment Volume corrector standards / regulations Basics of volume correction Gauge v Absolute
More informationdeltaflowc deltaflowc Venturi or Probe
deltaflowc Mass Flowmeter for Gases Multivariable with ultra fast dp, p and Tsensors Compact, accurate and userfriendly Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc
More information800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers
800 Series Mass Flow Meters and Controllers High Performance Mass Flow Meters and Controllers WHY MASS FLOW? In most processes it is mass, not volume, which is the critical variable. Volumetric flow measurements
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationFisher L2sj Low Emission Liquid Level Controller
L2sj Controller Product Bulletin Fisher L2sj Low Emission Liquid Level Controller The rugged Fisher L2sj low emission liquid level controller uses a displacer type sensor to detect liquid level. This controller
More informationSTANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4
Page 1 of 9 ` STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK-5102-00/J.02/0006-A4 Rev No. Issue Date Pages Rev Description Prepared A 12.08.08 9 Issued for Comments / Approval By Checked
More informationDOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD
ETV Platinum Plus R C O R P O R A T I O N Electronic Tempering Valve DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD Conforms to the following: ASSE 1017 California Lead Free Plumbing Law CSA B 125.3
More informationP9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6
P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,
More information