THE IMPACT OF PRESSURE AND SUCTION WAVES ON INSTALLED COMPONENTS, WITH PARTICULAR REFERENCE TO ENCLOSURES IN RAILWAY TUNNELS
|
|
- Doris Watson
- 5 years ago
- Views:
Transcription
1 THE IMPACT OF PRESSURE AND SUCTION WAVES ON INSTALLED COMPONENTS, WITH PARTICULAR REFERENCE TO ENCLOSURES IN RAILWAY TUNNELS ABSTRACT Heiko Holighaus Rittal Communication Systems, Haiger, Germany Environmental conditions in tunnels, which under certain circumstances can be extreme, place heavy demands on installed components. Enclosures, in particular, which are intended to protect other components from these environmental influences, have to be designed to be capable of coping with these conditions. This is the only way that the safety of the installed components and ultimately the safety of the tunnel can be improved. Considering each of the requirements in isolation is inadequate, however. Optimized holistic concepts are required. The effects of the environmental conditions to enclosures are considered as well as methods of resolution. Keywords: Enclosure design, tunnel application, environmental conditions 1. INTRODUCTION Tunnels are currently being planned and built in many different countries, both for road and rail traffic. They are being built, firstly, because of modern-day requirements for fast connections, and, secondly, because the space is simply not available to provide ideal routes using conventional means of construction. Hence, the biggest tunnel projects are currently to be found in the Alpine countries. At the same time, however, tunnels are also being built in countries which would not normally be associated with them at first thought, such as in the Netherlands. Longer tunnels, smaller tunnel cross-sections and higher traveling speeds place higher requirements on both the materials and components involved. To be able to work safely and reliably, the active components in particular have to be protected from all harmful environmental influences. The more effectively these components are protected from such influences, the greater safety of the tunnel. Standard enclosures are often unable to meet these requirements. At first consideration it might be assumed that the very fact that the components are installed in a tunnel would mean that they are well protected from all major weather influences. However, this view is deceptive, as closer scrutiny of the conditions in tunnels makes clear. Given that environmental conditions in railway tunnels are far more extreme than in any other types of tunnel, it is this type of tunnel which is the focus of this examination. 2. ENVIRONMENTAL CONDITIONS IN TUNNELS 2.1. Climatic conditions Climatic conditions in tunnels vary considerably depending on the length and nature of the tunnel. At the portals and the entry and exit areas it can be assumed that the climatic conditions are the same as in the open air. Deep inside tunnels through rock, on the other hand, conditions can be expected to be totally different. Here the air temperature will be between C and the level of air humidity will be high. In addition, it can also be expected that mountain water and/or condensation water will be dripping from overhead. The presence of salts brought into the tunnel from outside can also lead to the formation of aggressive media, and the concentration of these salts increases over time because there is no rain to wash them away.
2 The following table (Table 1) provides a summary of some of the typical climatic conditions which have to be accounted for: Temperature Temperature change Air humidity Salts Condensation water/mountain water Table 1: Typical climate conditions EN Railway application ETS Nonweatherprotected locations e.g. Customer specification C C C 0.5 C/min up to 20 C in total 0.5 C/min ± 30 K every 30 min % 8-100% % These climatic conditions provide a good basis for corrosion of all kinds. It is precisely these environmental conditions which often make higher quality, non-corrosive materials essential. In addition to treated sheet steel and aluminium, use is also made of stainless steels such as (V2A) or (V4A) Mechanical conditions In addition to the climatic conditions, a whole host of mechanical influences also have to be taken into consideration (see also Table 2). Falling rocks Dust Iron dust Concrete dust Rail rust Brake abrasion Vibrations Impacts Table 2: Typical mechanical conditions Pressure pulse Sand Dust Windpressure Vibration Shock EN Railway application ± kpa/s ETS Nonweatherprotected locations e.g. Customer specification --- ± 5 kpa mg/m³ 300 mg/m³ mg/m³ mg/(m²h) m/s 2,3 m/s² eff Hz 5 mg/m³ 20 mg/(m²h) m/s 1500 N/m² Hz Hz 1 m/s² Hz ms ms ---
3 Particular attention should be given to the dynamic fluctuations in air pressure. These should never be underestimated. Rise in pressure When a train travels through a tunnel it has a piston effect which generates a pressure wave ahead of it and a suction wave behind it (see Figure 1). Direction of travel Fall in pressure Figure 1: Pressure wave The level of the pressure wave depends on the speed of the train v, the cross-section of the tunnel A and the type of tunnel construction (single rail or multi-rail). What is important for the design of the enclosures and the dynamic response are the times during which the pressure is at its most extreme. For speeds of 300 km/s = 83 m/s and an enclosure width of 1m, the time for the train to pass by the enclosure is 12 ms. In reality, however, the actual change in pressure does not happen so fast. Measurements taken in a number of tunnels have demonstrated that the change in pressure from a maximum to minimum takes a number of seconds (8 seconds in Figure 2) Δp 6.5 kpa (A=82m², v=250 km/h = 70 m/s) Figure 2: Measurements recorded in an ICE tunnel in 1989
4 Measurements recorded in the Simplon tunnel (train speed v=140 km/h, pressure drop within 12 sec.) indicated that the typical pattern of air pressure development is as shown in Figure 3. Figure 3: Measurements recorded in the Simplon tunnel (Switzerland) in July 2005 Hence, the dynamic load on the enclosures is not a momentary surge, therefore, but a rapid change in pressure. 3. REQUIREMENTS OF ENCLOSURES 3.1. Requirements in relation to environmental conditions The environmental conditions described in section 2 lead to a range of requirements to be met by the enclosures if they are to provide adequate protection for the installed components. Protection from dust and water: Protection category IP65 or higher (in accordance with EN 60529) Climate control: Compliance with minimum or maximum temperatures for inside for the components in the enclosure (e.g C) Resistance to pressure: ±6.5 kpa (new requirement is ±10 kpa see section 3.2) Service life: years for passive components with a maintenance plan years for active components with a maintenance plan The special challenges here do not lie in trying to meet each of the requirements in isolation, but meeting them in combination. This means, for example, that the enclosure has to remain dust-tight even while the pressure is changing New requirements in terms of resistance to pressure Smaller tunnel cross-sections and high train speeds result in more severe conditions in respect of resistance to pressure. Whereas just a few years the maximum alternating load was still considered to be no more than ±5 kpa, it has now been raised to ±6.5 kpa, with some of the latest invitations for tenders even demanding ±10 kpa.
5 To illustrate what this means for an enclosure, where the typical size is 800 x 2000 mm² (width x height) and the alternating pressure is 10 kpa = N/m², the door has to be able to withstand a pressure of ±16000 N (which equates to a weight of 1.6 tons!). Are these new requirements justified or exaggerated? It is possible to check these new requirements on an approximate basis using empirical evidence in the railway tunnels where pressure differences of ±5kPa occur. Assumptions: Influence of a 10% reduction in the tunnel cross-section. Assuming an isentropic change of state, the laws of gases (equation (1)) can be used as the basis for estimating the increase in pressure. This produces a factor for the increase in pressure caused by the reduction in the crosssection as shown in equation (2): χ p V = const. (1) χ Air p V 1 0 1, 4 = = 1,11 = 1,157 p 0 V (2) 1 where p is the pressure, V the Volume and χ the adiabatic exponent. An increase in travelling speed from 220 km/h to 300 km/h (83 m/s). If the dynamic pressure (equation (3)) is taken into account for the increase in the travelling speed, the resultant factor is as follows (equation (4)): 1 2 p = ρ v (3) dyn 2 2 p km h = = 1,86 km p (4) h where p is the dynamic pressure, ρ is the density of air and v is the speed. The new pressure load is therefore calculated as follows: kn kn p1 = ( 1, ,86) p0 = 2, ,75 (5) 2 2 m m Hence, the new requirements of ±10 kpa are realistic for high speed trains in tunnels with reduced cross sections. 4. ALTERNATIVE SOLUTIONS 4.1. Design approaches A number of alternative design approaches come into consideration for ensuring that the enclosures meet the specified requirements. A) Reinforcements One alternative is to reinforce the enclosure in such a way that it would withstand the pressure loads under all circumstances while meeting all the other requirements such as protection from dust at the same time (see Figure 4). However, it has to be appreciated that the enclosure will certainly be more expensive if this approach is taken, because of the costs of the additional reinforcement.
6 Figure 4: Reinforcement of enclosures B) Pressure compensation The effort and expense of reinforcements can be eliminated if the enclosure can be provided with a means of pressure compensation. These days it is even possible to obtain pressure compensation solutions which are also dust-proof and waterproof at the same time. However, a major disadvantage of these is that they allow air humidity (water vapour) to penetrate the enclosure unhindered. The installed components must be suitable for relative humidities of up to 100%. Humidity penetrating the enclosure then becomes critical if a cooling unit is used for the air-conditioning in the enclosure. This is because the humid air can condense in the cooling unit, leading to more humid air coming into the enclosure (even reinforcing the process because of the pressure difference) and thus even more condensation water inside the enclosure. Good solutions are necessary to get the condensated water out of the enclosure due to the requirements of section 2! C) Seals Where seals are used for the doors and walls there are also a number of different options available. Rubber strip seals provide a very tight seal, such that the enclosures are very tightly sealed and the differences in pressure are maintained for a long time. However, the disadvantage of these is the sealing joint, because it has to be glued once the seal has been fitted. The alternative is to use PU foam seals which can be foamed-in without a seam. These seals have properties which permit faster pressure compensation without any loss of sealing effectiveness against dust. Figure 5: Sealing preventing dust coming into the enclosure (after 15 years tunnel application)
7 D) Lock systems What is important in lock systems is that the locking points are not too far apart. For an enclosure of 2 m in height, for example, three locking points will be insufficient under pressure. Under pressure the door can deform between the locking points, such that it is then no longer effectively sealed. In addition, a further problem with insufficient locking points is that the mechanical load on the individual locks may become too strong, meaning Figure 6: Locking system for three sides that failure is inevitable. The latest locking systems now also permit the top and bottom edges of the doors to be locked as well so that the door can now be secured all the way around (on the fourth edge by the hinges). E) Accessories The aforementioned requirements also apply to all other accessories such as cooling units, cable entry elements, indicator instruments, etc., with contacts to the outside Verification Once the concept has been developed the product should then be verified, ideally before completion of the design engineering phase. This is possible at an early stage with the aid of computations using finite element methods, for example. These can be used to look into both individual aspects and complete solutions. The following four illustrations (Figures 7 10) provide examples of calculation results. A pressure load of -10 kpa is put to the enclosure in Figure 7. The non-reinforced door will bend to the outside, displacements and forces will be to high for that door and the hinges (Figure 8). Figure 7: Pressure load Figure 8: Displacement of a non-reinforced door
8 After installing a reinforcement frame onto the door (Figure 9) the result of a new calculation show smaller displacements and forces to the door (Figure 10). Figure 9: Reinforcement frame Figure 10: Deformation in a reinforced door However, in addition to theoretical considerations and computations it is also imperative that suitable tests are performed on prototypes. One reason for this is that in many cases not all of the components of the enclosure are depicted in the theoretical models and the models themselves involve necessary simplifications. Since special tests of this kind, such as pressure tests, are not covered by any standards, manufacturers have to rely on their own creativity to develop and carry out their own tests. The alternative is to commission a suitable institute to carry out the development work and supervision at a cost. Figure 11 shows a measuring arrangement for carrying out alternating pressure tests involving 200,000 pressure changes of Pa. This arrangement has a corresponding upstream control unit and data logger for performing and analysing the tests. Figure 11 also shows several pressure load cycles from this test Pressure [mbar] :28:02 11:28:12 11:28:23 11:28:33 Time Figure 11: Pressure test set-up and measured data for +5 kpa According to the new pressure requirements a new test has been developed to simulate pressure cycles of the enclosure with pressure differences of ±10 kpa (see Figure 12). For 200,000 cycles this test takes 25 days (24 hours).
9 :17:11 10:17:20 10:17:28 10:17:37 10:17:46 Time Figure 12: Pressure test and measured data for ±10 kpa The test also permits theoretical computations to be checked, which guarantees that the computation parameters and boundary values specified in the finite element calculations are more reliable. Figure 13 shows such a check during a pressure test on a non-reinforced door. The door displacement at 20mbar underpressure is 30 mm (800 mm wide door in this instance)! Pressure [mbar] Figure 13: Displacement of a non-reinforced door at 20mbar underpressure 5. SUMMARY It has been demonstrated that the diverse high requirements made of enclosures cannot be treated in isolation but have to be brought together in a single concept in order to achieve maximum safety and reliability for all components involved. From a rough calculation it is apparent that the latest new requirements regarding pressure differences are realistic. In addition to theoretical computations of loads, tests are absolutely imperative because not all details can be accounted for in models. Overall there is a requirement for optimized, suitable climate control solutions and simple and efficient maintenance solutions which are specifically designed for an integrated concept. Given the diversity of components that customers want installing and the wide variations in power losses involved it will always be impossible to develop a standardized enclosure solution. Nevertheless, service-proven solutions can always be used as the initial point of reference, at least, for the development of something new. 6. REFERENCES Physik für Ingenieure, Hering, Martin, Stohrer; 5.Auflage 1995, VDI-Verlag Kraftfahrtechnisches Taschenbuch Bosch, 21. Auflage 1991, Düsseldorf, VDI-Verlag EN EN EN ETS EN
enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)
enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) Stainless steel and plastic enclosures for use in potentially explosive environments R Rittal system partners Perfect
More informationenclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)
lri030784900.eps lri031083400.eps enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) fri040466500.eps Stainless steel and plastic enclosures for use in potentially explosive
More informationCONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS
- 56 - CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS Gloth O., Rudolf A. ILF Consulting Engineers Zürich, Switzerland ABSTRACT This article investigates the
More informationNUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT
- 277 - NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT Iseler J., Heiser W. EAS GmbH, Karlsruhe, Germany ABSTRACT A numerical study of the flow behaviour
More informationSafety, ventilation and climate in rail tunnels
INTERNATIONAL SEMINAR LONG TUNNELS Safety, ventilation and climate in long rail tunnels Safety, ventilation and climate in rail tunnels Bernd Hagenah 17, 18 y 19 de Octubre 2012 Santiago, Chile Safety,
More informationTIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.
TIGHTNESS Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements. ODU has the necessary expertise for developing and manufacturing connectors
More informationAutomatic Isokinetic Sampler. ST5 Evo
Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,
More informationICHEME SYMPOSIUM SERIES NO. 144
EXPLOSION VENTING - THE PREDICTED EFFECTS OF INERTIA By Steve Cooper - Stuvex Safety Systems Limited Explosion venting is an established and well used method of primary explosion protection within industry.
More informationGuide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin
Guide No. 2/2009 THE ROAD TO a mass laboratory Design, training and equipment Martin Firlus Physikalisch Technische Bundesanstalt Braunschweig und Berlin Imprint Published by: Responsible: Text: Layout:
More informationTRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.
TRZ 0-K Volumeter TRZ 0-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Turbine Gas Flowmeter continues the tradition of Honeywell s field-proven turbine meter technology, delivering
More informationVSR modulating valves with membrane actuator
Modulating valves are used in process technology to control process parameters such as temperature, pressure or flow when handling liquid and gaseous media. uth's team of design and process engineers have
More informationExperiment Instructions. Circulating Pumps Training Panel
Experiment Instructions Circulating Pumps Training Panel Experiment Instructions This manual must be kept by the unit. Before operating the unit: - Read this manual. - All participants must be instructed
More informationSimple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18
The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 143 N 143 SP.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central
More informationAN ANALYSIS ON HIGH PRESSURE DYNAMIC CALIBRATORS USED IN THE DEFENSE AREAS
AN ANALYSIS ON HIGH PRESSURE DYNAMIC CALIBRATORS USED IN THE DEFENSE AREAS Sung Soo HongPresenter Agency for Defense Development, Taean, 357-942, South Korea sungsoo@add.re.kr Abstract Up to now, there
More informationSimon Peggs, dipl. eng. FH AlpTransit Gotthard Ltd., Lucerne, Switzerland / Project Manager Mechanical Equipment GBT
Safety doors in the world s longest tunnel under the Gotthard: outstanding requirements and performance. Feed-back from the bidding phase and results from the testing phase on selected prototypes Davide
More informationWorkshop Compressors CLASSIC Series
www.kaeser.com Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your Classic workshop compressor? Quality results can be achieved only by using
More informationFlow in a shock tube
Flow in a shock tube April 30, 05 Summary In the lab the shock Mach number as well as the Mach number downstream the moving shock are determined for different pressure ratios between the high and low pressure
More informationVENTILATION OF PROTECTED AREAS IN ROAD TUNNELS
- 187 - VENTILATION OF PROTECTED AREAS IN ROAD TUNNELS ABSTRACT Zumsteg F., Steinemann U. US+FZ Beratende Ingenieure, CH-5600 Lenzburg P. Wildi Civil Eng. Dept. Canton Grisons, CH-7000 Chur During the
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its
More informationW E NE E D TO TA LK A BOUT COLD FLOW. The Problem With The Cold Flow Standard.
W E NE E D TO TA LK A BOUT COLD FLOW The Problem With The Cold Flow Standard www.ehawke.com CONTENTS 03 COLD FLOW AND THE STANDARDS The Cold Flow Standard misnomer The Problem with Compression and Displacement
More informationEFFECTIVE DESIGN OF CONVERTER HOODS. 111 Ferguson Ct. Suite 103 Irving, Texas U.S.A. 400 Carlingview Dr. Toronto, ON M9W 5X9 Canada.
EFFECTIVE DESIGN OF CONVERTER HOODS Paykan Safe 1, Sam Matson 1, and John Deakin 2 1 Gas Cleaning Technologies 111 Ferguson Ct. Suite 103 Irving, Texas 75062 U.S.A. 2 H.G. Engineering, Ltd. 400 Carlingview
More informationTutorial. BOSfluids. Relief valve
Tutorial Relief valve The Relief valve tutorial describes the theory and modeling process of a pressure relief valve or safety valve. It covers the algorithm BOSfluids uses to model the valve and a worked
More informationHigh Speed Rail Tunnel Aerodynamics: Transient pressure and loadings on fixed tunnel equipment
High Speed Rail Tunnel Aerodynamics: Transient pressure and loadings on fixed tunnel equipment Mohammad Tabarra & Richard Sturt Arup, UK Summary: Trains entering tunnels at high speeds can generate highly
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationFire- & smoke- tight sliding door FST High quality for demanding architecture
High quality for demanding architecture EPD and ISO certification High quality for demanding architecture 1. Variability 1. Single leaf version right or left opening 2. Double leaf version center closing
More informationFire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations
Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations Grzegorz Kubicki, Ph.D. Department of Environmental Engineering, Warsaw University of Technology
More informationPress Release. Friction Stir Welding: Grenzebach extends its portfolio
Friction Stir Welding: Grenzebach extends its portfolio Higher dynamics, higher welding speeds, lower process forces and even higher quality welding seams and welding surfaces: at the Düsseldorf Schweissen
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationF13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS
F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS F13.11 01.06.2018 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. General...F13.11.03
More informationControl of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA)
Control of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA) ABSTRACT M.J. Crossley AEA Technology ES. Inc. 1100 Jadwin Ave, Richland, WA 99352, USA This paper describes
More informationVibration Analysis and Test of Backup Roll in Temper Mill
Sensors & Transducers 2013 by IFSA http://www.sensorsportal.com Vibration Analysis and Test of Backup Roll in Temper Mill Yuanmin Xie College of Machinery and Automation, Wuhan University of Science and
More informationSmoke and gas tightness of Hilti Firestop products
Smoke and gas tightness Smoke and gas tightness of Hilti Firestop products The enclosed pages are taken from the Brochure Smoke and gas tightness Edition 2006 Please note the tables in this extract may
More informationRELIABILITY ASSESSMENT, STATIC AND DYNAMIC RESPONSE OF TRANSMISSION LINE TOWER: A COMPARATIVE STUDY
RELIABILITY ASSESSMENT, STATIC AND DYNAMIC RESPONSE OF TRANSMISSION LINE TOWER: A COMPARATIVE STUDY Yusuf Mansur Hashim M. Tech (Structural Engineering) Student, Sharda University, Greater Noida, (India)
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationXTS-Impact. XTS-Terminal (hold)
XTS-Impact The XTS-Impact is used to support the XTS-Linked system, as a standalone anchorage point and as an anchorage point in horizontal temporary lifeline systems. The anchorage point is tested according
More informationPAS 13:2017 Safety Barriers within the Workplace
Raising Awareness, Setting Standards and Making the Workplace Safer PAS 13:2017 Safety Barriers within the Workplace Neil Clifford - Managing Director - A Safe UK Who are A-SAFE Established 1984 Over 30
More informationAquashield to Mitigate Water Ingress of Gas Pipes
IGEM Young Persons Paper Competition 2017 Aquashield to Mitigate Water Ingress of Gas Pipes Assistant Engineer Technical Development Section, Distribution Operation Department The Hong Kong and China Gas
More informationCFSW. Hinges with built-in safety multiple switch
CFSW. Hinges with built-in safety multiple switch ELESA Original design Elesa Standards Main dimensions Fitting Weight Code Description L B f ±0.2 f 1 ±0.2 H h 1 h 2 d 3 d 4 C [Nm]# g 426601 CFSW.110-6-2NO+2NC-C-A
More informationCHAPTER 5: VACUUM TEST WITH VERTICAL DRAINS
CHAPTER 5: VACUUM TEST WITH VERTICAL DRAINS 5.1 Introduction Using surcharging as the sole soil consolidation mean can take a long time to reach the desired soil settlement. Soil consolidation using prefabricated
More informationSea-going vessel versus wind turbine
Collision risk at high sea Sea-going vessel versus wind turbine Offshore wind power: Wind turbines off the German coast generally represent obstacles in the traffic routes of ships. What if a large sea-going
More informationLiquid Ring Compressors Engineered-to-Order Compressor Systems
Liquid Ring Compressors Engineered-to-Order Compressor Systems NASH Liquid Ring Compressors Greatest Performance Range of Liquid Ring Compressors Worldwide The ability to compress wet, saturated or dirty
More informationApplication of Simulation Technology to Mitsubishi Air Lubrication System
50 Application of Simulation Technology to Mitsubishi Air Lubrication System CHIHARU KAWAKITA *1 SHINSUKE SATO *2 TAKAHIRO OKIMOTO *2 For the development and design of the Mitsubishi Air Lubrication System
More informationDIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM
DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external
More informationTHE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM
THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM What is pressure drop in a compressed air utility? Pressure drop is a term used to characterize the reduction in air
More informationTECHNICAL BENEFITS OF CJS / RAISE HSP. Technical Advantages
TECHNICAL BENEFITS OF CJS / RAISE HSP Technical Advantages The HSP is designed for low- to mid- volume applications at flow rates of 1 cubic meter to 30 c. m per day. The benefits are in the details. The
More informationOpening and closing force guidelines
Opening and closing force guidelines This document has been complied under guidance of ASDMA membership to provide information on the requirements of Part M of the Building regulations with regards to
More informationDesign Enhancements on Dry Gas Seals for Screw Compressor Applications
VDI-Berichte Nr. 1932, 2006 B 8 331 Design Enhancements on Dry Gas Seals for Screw Compressor Applications Dipl.-Ing C. Kirchner, Flowserve Dortmund GmbH & Co KG, Dortmund Introduction The development
More informationDigital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN
Data Sheet: DFP.418.R4.EN www.ntt.dk Digital Pressure Gauge PRESSURE FORCE The DFP series digital gauges are made according to the more modern technologies in order to provide a high level of reliability,
More informationAutomatic extractor outlet
L-07-2-01e Automatic extractor outlet Type HFA Contents Application Realisation Operation Safety instructions Contents Application Realisation Operation Safety instructions 2 Connection diagram Dimensions
More informationAN INVESTIGATION OF LONGITUDINAL VENTILATION FOR SHORT ROAD TUNNELS WITH HIGH FIRE HRR
- 9 - AN INVESTIGATION OF LONGITUDINAL VENTILATION FOR SHORT ROAD TUNNELS WITH HIGH FIRE HRR O Gorman S., Nuttall R., Purchase A. Parsons Brinckerhoff, Australia ABSTRACT Recent fire tests for tunnels
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationVortex Meters for Liquids, Gas, and Steam
A Measuring Principle Comes of Age: Vortex Meters for Liquids, Gas, and Steam Dipl.-Hyd. Oliver Seifert, Product Management Vortex Meters at Flowtec AG, and Ellen-Christine Reiff, M.A., Editor s Office,
More informationE. Agu, M. Kasperski Ruhr-University Bochum Department of Civil and Environmental Engineering Sciences
EACWE 5 Florence, Italy 19 th 23 rd July 29 Flying Sphere image Museo Ideale L. Da Vinci Chasing gust fronts - wind measurements at the airport Munich, Germany E. Agu, M. Kasperski Ruhr-University Bochum
More informationOffshore Wind Turbine Operations & Maintenance Solutions
Offshore Wind Turbine Operations & Maintenance Solutions Limpet - Next Generation Climb Assist Limpet - partnering with leading turbine OEMs onshore Senvion MM82 GE XLE 1.6 Vensys 1.5 Siemens SWT-2.3-93
More informationRefrigeration Scroll For Parallel Applications
Refrigeration Scroll For Parallel Applications Application Guideline 1 Scroll Compressors in Parallel for Refrigeration Applications 1. Introduction The concept of parallel operation for refrigeration
More informationWP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment
Part 4 WP - 269 Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment Even using specialised weld purging equipment does not guarantee defect free welds. Control of the oxygen content
More informationDetermination of the wind pressure distribution on the facade of the triangularly shaped high-rise building structure
Determination of the wind pressure distribution on the facade of the triangularly shaped high-rise building structure Norbert Jendzelovsky 1,*, Roland Antal 1 and Lenka Konecna 1 1 STU in Bratislava, Faculty
More informationLiquid Ring Compressors Engineered-to-Order Compressor Systems
Liquid Ring Compressors Engineered-to-Order Compressor Systems NASH Liquid Ring Compressors Greatest Performance Range of Liquid Ring Compressors Worldwide The ability to compress wet, saturated or dirty
More informationAlso suitable for: Concrete C12/15. For fixing of: Steel constructions Railings Consoles Ladders Wooden constructions Cable trays Machines Staircases
28 Highbond anchor FHB II Flexible installation and highest loads in the cracked tensile zone. OVERVIEW FHB II-A S (standard), zinc plated steel FHB II-A L (performance optimised), zinc-plated steel Resin
More informationPressure reducing valves Index
Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel
More informationDETRMINATION OF A PLUNGER TYPE WAVE MAKER CHARACTERISTICE IN A TOWING TANK
The 9 th International Conference on Coasts, Ports and Marine Structures (ICOPMAS 2010) 29 Nov.-1 Dec. 2010 (Tehran) DETRMINATION OF A PLUNGER TYPE WAVE MAKER CHARACTERISTICE IN A TOWING TANK sayed mohammad
More informationTemperature, salinity, density, and the oceanic pressure field
Chapter 2 Temperature, salinity, density, and the oceanic pressure field The ratios of the many components which make up the salt in the ocean are remarkably constant, and salinity, the total salt content
More informationOperational Behaviour of Safety Valves with Constant Superimposed Backpressure
Operational Behaviour of Safety Valves with Constant Superimposed Backpressure Arne Gastberg Albert Richter ARI-Armaturen GmbH & Co. KG When selecting spring loaded safety valves, an accurate knowledge
More informationMagnetic level switch type MR783 Instruction Manual
Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2
More informationOPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL. Rehan Yousaf 1, Oliver Scherer 1
OPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL Rehan Yousaf 1, Oliver Scherer 1 1 Pöyry Infra Ltd, Zürich, Switzerland ABSTRACT Gotthard Base Tunnel with its 57 km
More informationLiquid Ring Compressors Engineered-to-Order Compressor Systems
Liquid Ring Compressors Engineered-to-Order Compressor Systems NASH Liquid Ring Compressor Systems Engineered-to-Order Liquid Ring Compressor Systems Unmatched experience Nash liquid ring compressors are
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are
More informationSTANDARD PROCEDURE OF A TIGHTNESS TEST OF A SOLAR COLLECTOR BOX. (EUROSUN 2000 SOLAR CONGRESS)
STANDARD PROCEDURE OF A TIGHTNESS TEST OF A SOLAR COLLECTOR BOX. (EUROSUN 2000 SOLAR CONGRESS) Ole Holck and Svend Svendsen Department of Buildings and Energy, Technical University of Denmark Building
More informationErmenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision
Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision J.Linortner & R.Faber Pöyry Energy GmbH, Turkey-Austria E.Üzücek & T.Dinçergök General Directorate of State Hydraulic
More informationUNIT 15 WATER HAMMER AND SURGE TANKS
UNT 15 WATER HAMMER AND SURGE TANKS Structure 15.1 ntroduction Objectives 15.2 Water Hammer 15.2.1 Expression for Rise in Pressure 15.3 Rapid Acceleration of Flow 15.4 Surge Tanks 15.5 Summary 15.6 Keywords
More informationUltrasonic level transmitter and indicator
Ultrasonic level transmitter and indicator No contact with the product Compact design with polycarbonate housing (electronics and display). Remote display available on request Very good resistance in corrosive
More informationVentilation of Small Multispan Greenhouse in Relation to the Window Openings Calculated with CFD
Ventilation of Small Multispan Greenhouse in Relation to the Window Openings Calculated with CFD J.B. Campen Plant Research International Wageningen The Netherlands Keywords: greenhouse design, wind direction,
More informationDevelopment of TEU Type Mega Container Carrier
Development of 8 700 TEU Type Mega Container Carrier SAKAGUCHI Katsunori : P. E. Jp, Manager, Ship & Offshore Basic Design Department, IHI Marine United Inc. TOYODA Masanobu : P. E, Jp, Ship & Offshore
More informationStructural Design and Analysis of the New Mobile Refuge Chamber
Key Engineering Materials Online: 2013-09-10 ISSN: 1662-9795, Vol. 584, pp 175-178 doi:10.4028/www.scientific.net/kem.584.175 2014 Trans Tech Publications, Switzerland Structural Design and Analysis of
More informationHigh-speed pressure sensor Model CPT6140
Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications
More informationThe Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through
More informationAIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE
- 247 - AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE J D Castro a, C W Pope a and R D Matthews b a Mott MacDonald Ltd, St Anne House,
More informationSizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios
Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios Yunlong (Jason) Liu, PhD, PE HNTB Corporation Sean Cassady, FPE HNTB Corporation Abstract Extraction
More informationDigital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request
Data Sheet: BIT02B.417.R6.EN www.ntt.dk Digital Pressure Gauge COVER on request Bit02B digital gauge series is proposed as the cheaper version of LabDMM but guarantees all the functional characteristics
More informationCFSW. Hinges with built-in safety multiple switch
CFSW. Hinges with built-in safety multiple switch ELESA Original design technical informations Material - Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black colour. Resistant to solvents,
More informationDesigning a Traffic Circle By David Bosworth For MATH 714
Designing a Traffic Circle By David Bosworth For MATH 714 Abstract We all have had the experience of sitting in a traffic jam, or we ve seen cars bunched up on a road for some no apparent reason. The use
More informationPremium Series: Pressure, Differential Pressure and Level Transmitters. PASCAL Ci4. Chemical industry Mechanical engineering Process industry
Made to measure. Since 1968. Premium Series: Pressure, Differential Pressure and Level Transmitters PASCAL Ci4 Chemical industry Mechanical engineering Process industry PREMIUM SERIES THE INTUITIVE ONE
More informationFail-Safe Design by Outer Cover of High Pressure Vessel for Food Processing
Open Journal of Safety Science and Technology, 2011, 1, 89-93 doi:10.4236/ojsst.2011.13009 Published Online December 2011 (http://www.scirp.org/journal/ojsst) Fail-Safe Design by Outer Cover of High Pressure
More information2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES
Industry Guidelines Part 2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES ISSUE 5.1 Ref: POP10B 15 MAR 2010 Disclaimer In formulating this guideline PIPA has relied
More informationTHE INFLUENCE OF THE NOSE SHAPE OF HIGH SPEED TRAINS ON THE AERODYNAMIC COEFFICIENTS
THE INFLUENCE OF THE NOSE SHAPE OF HIGH SPEED TRAINS ON THE AERODYNAMIC COEFFICIENTS Heine Ch. and Matschke G. Deutsche Bahn AG, Research and Technology Centre Voelckerstrasse 5, D-80939 Munich, Germany
More informationAerodynamic study of a cyclist s moving legs using an innovative approach
Aerodynamic study of a cyclist s moving legs using an innovative approach Francesco Pozzetti 30 September 2017 Abstract During a period of four weeks in September, I completed a research project in fluid
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital
More informationOPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26
OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 Made For: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia WARNING: FAILURE TO FOLLOW OPERATING, SAFETY AND MAINTENANCE
More informationJournal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1)
Modeling and Field Verification Study of Air Slam Conditions on kalanit Pipeline System By Yiftach Brunner & Sathish Kumar ir valves are integral part of long water transmission mains and are essential
More informationPremium Solutions for Gas and Biogas Handling
Premium Solutions for Gas and Biogas Handling Blower Solutions for Gas & Biogas Type of gas Applications Application requisites Specific characteristics of the blower unit Premium Solutions for Gas and
More informationJAR-23 Normal, Utility, Aerobatic, and Commuter Category Aeroplanes \ Issued 11 March 1994 \ Section 1- Requirements \ Subpart C - Structure \ General
JAR 23.301 Loads \ JAR 23.301 Loads (a) Strength requirements are specified in terms of limit loads (the maximum loads to be expected in service) and ultimate loads (limit loads multiplied by prescribed
More informationSUBPART C - STRUCTURE
SUBPART C - STRUCTURE GENERAL CS 23.301 Loads (a) Strength requirements are specified in terms of limit loads (the maximum loads to be expected in service) and ultimate loads (limit loads multiplied by
More informationFLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN
FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN George Feng, Kinetics Noise Control, Inc., 3570 Nashua Drive, Mississauga, Ontario Vadim Akishin, Kinetics Noise Control, Inc., 3570 Nashua Drive, Mississauga,
More informationImprovement of the Volumetric and Isentropic Efficiency Due to Modifications of the Suction Chamber
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2008 Improvement of the Volumetric and Isentropic Efficiency Due to Modifications of the
More informationMaintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry
Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry Article Takeaways: Chris Doerschlag President ALB Klein Technology Group www.albkleinco.com 1. Troubleshooting Guide
More informationIGUMA - IGU Design Limitations
1/5 IGUMA - IGU Design Limitations Introduction Insulating Glass Units (IGU s) are being used more frequently in domestic and commercial buildings to provide improved insulation, comfort, condensation
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down
More informationViega Advantix Vario. Millimetre precision. Unlimited flexibility.
Viega Advantix Vario Millimetre precision. Unlimited flexibility. Viega Advantix Vario Individuality in its most beautiful form. Demanding design and high-quality materials have long since been par for
More information