LAZY RIVER 3 3 PUMP LOCATION

Size: px
Start display at page:

Download "LAZY RIVER 3 3 PUMP LOCATION"

Transcription

1 .0 1 TEE WITH () " RETURN NOZZLE " OR 1 SCH 0 PVC PIPE RETURN WITH ACCELERATOR NOZZLE 2 LAZY RIVER PUMP LOCATION PUMP LOCATION PRELIMINARY SITE LAYOUT AND PUMP LOCATION 1 DETERMINE CURRENT RETURN LOCATION AND ANGLE (AS PER PLAN) 2 DETERMINE PIPE ROUTING AND ANGLE FROM RETURN TO PUMP LOCATION. ANGLES ARE TO BE BASED ON FACTORY FITTINGS SUCH AS 11.2, 22.,, 90 ELBOWS ONLY. ROTATE PUMP TEE TO MEET RETURN PIPE ANGLE. DETERMINE SUCTION DRAIN LOCATION AND PIPE ROUTING AND ANGLE FROM SUCTION OUTLETS TO PUMP LOCATION. ANGLES ARE TO BE BASED ON FACTORY FITTINGS SUCH AS 11.2, 22.,, 90 ELBOWS ONLY.ROTATE 1 SUCTION 90 ELBOW AS NEEDED TO MEET SUCTION PIPING ANGLE. DIG ' WIDE X ' DEEP TRENCH FOR PIPE ROUTING AND PUMP PLACEMENT NOTE: RETURN PIPING PLANNING DETERMINES PUMP LOCATION BASED ON ANGLES OF PIPING REQUIRED TO MEET PROPER INSTALLATION OF RETURN FITTING TO PRODUCE CURRENT IN DIRECTION OF JUST OFF CENTER OF STREAM CENTERLINE. PLACEMENT OF RETURN FITTING AND SET ANGLE OF FLOW IS FIRST PRIORITY IN DETERMINING SYSTEM LAYOUT. 2 & ON PG. 1 TEE WITH 1 () " RETURN NOZZLE 2 10" OR 1 SCH 0 PVC PIPE RETURN WITH ACCELERATOR NOZZLE '-0" '-0" PRELIMINARY SYSTEM LAYOUT 1 OF

2 2 & ON PG. 1 TEE WITH 1 () " RETURN NOZZLE 2 10" OR 1 SCH 0 PVC PIPE RETURN WITH ACCELERATOR NOZZLE '-0" '-0" ON PG. 1 1 TEE WITH () " RETURN NOZZLE CLEARANCE FOR REMOVAL CLEARANCE FOR REMOVAL '-0" TO '-0" 10" 2 & ON PG. 6 1 SCH 0 PVC PIPE RETURN 1'- 1 2 " " '-0" TO '-0" 1'-" ON PG SCH 0 PVC PIPE SUCTION LINE 6 1'- 1 2 " " 1 1 TEE WITH () " RETURN NOZZLES TO BE SET 10" BELOW WATER LINE TO RETURN 2 STRAIGHT RETURN PIPE WITH ACCELERATOR NOZZLE IS TO BE SET 10" BELOW WATER LINE TO OF PIPE ROTATE PUMP RETURN TEE AS NEEDED TO MEET RETURN PIPING ANGLE PLACE PUMP AND 90 SUCTION FITTING AT APPROPRIATE HEIGHT TO MEET RETURN PIPING ELEVATION. DRY FIT ALL PIPING FOR PROPER FIT AND ALIGNMENT BEFORE GLUEING IN PLACE. SUCTION PIPING TO 90 ELBOW IS TO BE PIPED USING ONLY FACTORY FITTINGS SUCH AS 11.2, 22.,, 90 ELBOWS AS NEEDED. DRY FIT ALL PIPING FROM RETURN TO PUMP & FROM PUMP TO SUCTION BOXES BEFORE GLUEING IN PLACE. 6 POUR ' X ' X " THICK SLAB BELOW BOTTOM FLANGE FOR PUMP SUPPORT PAD. 2 10" OR 1 PIPE RETURN WITH ACCELERATOR NOZZLE " CLEARANCE FOR REMOVAL " CLEARANCE FOR REMOVAL '-6" TO '-0" 10" 10" OR 1 SCH 0 PVC PIPE RETURN " '-6" TO '-0" ON PG. 22. " SCH 0 PVC PIPE SUCTION LINE PIPING INSTALLATION 2 OF

3 DUAL SUCTION 12 X ON PG. GUNITE APPLICATION ACCLERATOR NOZZLE IN PIPE RIVERFLOW PUMP 1,, ON PG. 10 X ACCLERATOR NOZZLE IN PIPE 1 TEE WITH () " RETURNS VARIABLE SPEED DRIVE VARIABLE SPEED DRIVE COVER BACK 2,, ON PG. OF

4 1 2 OF

5 1 2 OF

6 WATER LINE RIVER BEAM 10" OR 1 SCH 0 RETURN PIPE MAXIMUM PUMP HEIGHT WITH OF BOTTOM FLANGE AT OR BELOW WATER LINE 1 SCH 0 SUCTION PIPE FROM MAIN DRAIN BOXES VERTICAL PUMP INSTALLATION SCALE N.T.S. CRITICAL NOTE: THIS SYSTEM IS A FLOODED SUCTION SYSTEM. TO MAINTAIN FLOODED SUCTION PUMP INSTALLATION MUST ADHERE TO MAXIMUM HEIGHT IN RELATION TO WATER LINE. VERTICAL INSTALLATION: PUMP FLANGE GASKET MUST MEET MAXIMUM HEIGHT AT WATER LINE OR LOWER. PIPE FITTINGS ARE REQUIRED TO MAINTAIN 10" BELOW WATER LEVEL. REFER TO SECTIONS AND PLANS FOR PUMP ELEVATION AND REQUIRED FITTINGS AS PER PROJECT APPLICATION. 6 OF

7 2'-0" PATIO OR DECK PATIO OR DECK T.B.D. " " " CRITICAL DIMENSION OF PIPE BELOW WATER LINE SWIM POOL " BELOW WATER LINE LAZY RIVER 10" BELOW WATER LINE PUMP IS TO BE SET PER OF PIPE REQUIREMENTS. NOTE: PUMP MAY BE BELOW WATER LINE USING FITTINGS TO ELEVATE RETURN PIPE TO PIPE DEPTH REQUIREMENTS. 10" or 1 SCH 0 PVC RETURN PIPE TO APPROVED SEWER OR FRENCH DRAIN 1 X 10" REDUCING BUSHING 1 SCH 0 PVC SUCTION PIPE 1 90 ELBOW 2'-0" CAP / COPING STONES ABOVE GRADE MAXIMUM PUMP HEIGHT (WATER LINE AT OF BOTTOM FLANGE) " T.B.D. " CRITICAL DIMENSION OF PIPE BELOW WATER LINE SWIM POOL " BELOW WATER LINE LAZY RIVER 10" BELOW WATER LINE PUMP IS TO BE SET PER OF PIPE REQUIREMENTS. NOTE: PUMP MAY BE BELOW WATER LINE USING FITTINGS TO ELEVATE RETURN PIPE TO PIPE DEPTH REQUIREMENTS. 10" or 1 SCH 0 PVC RETURN PIPE " TO WASTE CAST IN PLACE CONCRETE PUMP BASE ALLOW CLEARANCE BETWEEN BOTTOM FOR FLANGE BOLT ACCESS. 1 X 10" REDUCING BUSHING 1 SCH 0 PVC SUCTION PIPE 1 90 ELBOW CONCRETE PUMP BASE OF

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM I N S TA L L AT I O N / I MN SA TA I N TL EL NAT AIN OC N E / MI AN IS NT RE UN CA TN I CO E N SI N S T R U C T I O N S INSTALLATION INSTRUCTIONS FOR -FRU OPTION Important: Read all instructions and refer

More information

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed Quality Plastic Pipe Fittings Technical Data Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed Effective April 1, 2002 PIPE DIMENSIONS IPS-IRON PIPE SIZE Minimum

More information

Installation Instructions

Installation Instructions Installation Instructions Splashdown Fountain The Splash Down telescoping fountainhead comes in two sizes: the SD22 for use in water depths from 6 to 24 inches and the SD44 for use in water depths of 25

More information

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED Installation Guide Fiji Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED In planning for the installation of a new Viking pool, there are many important considerations that must be evaluated in order

More information

Hydrotherapy Jets System for a Fiberglass Pool

Hydrotherapy Jets System for a Fiberglass Pool Page 1 of 5 Parts List 1-50 Flex PVC pipe 2-1 1 / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 6 - Female slip/female slip unions 2 - Female slip/fpt union

More information

Swimming Pools, Hot Tubs and Spas

Swimming Pools, Hot Tubs and Spas OLATHE FIRE DEPARTMENT BUILDING CODES 1225 S. Hamilton Circle Olathe, KS 66061 / Main: (913) 971-7900 / Fax: (913) 971-9812 Swimming Pools, Hot Tubs and Spas Definitions: Swimming Pool- Any structure intended

More information

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN Important: Read all instructions and refer to local codes prior to installation. l Local soil conditions may require more gravel for drainage. l

More information

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Fiberstars Light Streams Mini Laminar Installation Manual (LSML) 3072091 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15056-00 Rev. A Page 1 of 6 SAVE THESE INSTRUCTIONS!

More information

Big Ride ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * *

Big Ride ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * * Big Ride ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * * S.R. SMITH BIG RIDE SLIDES ARE MANUFACTURED FOR INSTALLATION AND USE ON INGROUND SWIMMING POOLS ONLY. THE BIG RIDE IS NEVER TO BE INSTALLED

More information

22. Specialty Valves.

22. Specialty Valves. 22. Specialty Valves. a. Types of Specialty Valves. 1) Use of the following specialty valves is covered in this section: Altitude Valve, Pressure Reducing Valve, Pressure Relief Valve, Swing Check Valve,

More information

Swimming Pool Requirements

Swimming Pool Requirements Swimming Pool Requirements 1. Definitions: Approved Safety Pool Cover. Means a manually or power-operated safety pool cover that meets all of the performance standards of the American Society for Testing

More information

Swimming Pool Requirements Packet

Swimming Pool Requirements Packet Plot Plans shall indicate the following: Drawn to an appropriate scale with pool depths shown and dimensions to other structures Have an engineer address any surcharge loads on the pool or from the pool

More information

T Y P E V S A B M S E W A G E P U M P

T Y P E V S A B M S E W A G E P U M P Pe r fo r m a n ce C h a r t s 11 1 D R Y P I T S B U L L E T I N 2 3 9 8 7 6 5 4 3 2 1 12 11 1 / 4 1 1 / 2 9 3 / 4 9 5% 3 HP 5 HP 7 1/2 HP 1 HP 76% 5% C u r v e P a g e V S A B M - 4 1 1 5 R P M M O D

More information

Swim Spa Pre-delivery Guide

Swim Spa Pre-delivery Guide Swim Spa Pre-delivery Guide Hello! This document is designed to provide all the information you need to ensure the smooth delivery and installation of your spa or swim spa. Please read it carefully and

More information

You are now the proud new owner of an Alpine Swim Spa!

You are now the proud new owner of an Alpine Swim Spa! Congratulations! You are now the proud new owner of an Alpine Swim Spa! Your Swim Spa will soon be ready and waiting for the whole family to enjoy. This Pre-Delivery guide is designed to ensure that the

More information

Multi-Flow Product Catalog

Multi-Flow Product Catalog Multi-Flow Product Catalog Multi-Flow offers a variety of multi-purpose reducing connectors (06005-0600N, 12005-1200Q, and 18005-1800Q) that allow for complete flexibility in the design of drainage patterns.

More information

RIVERFLOW PUMP INSTALLATION GUIDE

RIVERFLOW PUMP INSTALLATION GUIDE 2-0 3-8 By: By: TABLE OF CONTENTS 3 4 20 21 22 5 6 7 8 9 14 15 16 17 18 19 RIVERFLOW SYSTEM OVERVIEW COMPONENTS CHECKLIST & ACTIVATION MOTOR MOUNT COVER CONTRACTOR S FINAL CHECKLIST PLUMBING INSTALLATION

More information

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE

RESIDENTIAL SWIMMING POOLS, SPAS and HOT TUBS PERMITTING and INSPECTIONS GUIDE Inspections & Permits Department 316 North Academy Street Cary, NC 27513 (919) 469-4046 Fax: (919) 462-3840 Email: BuildingSafety@townofcary.org www.townofcary.org RESIDENTIAL SWIMMING POOLS, SPAS and

More information

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual 27.75 23.75 25.50 20.75 Specifications: 8-13 GPM 100 strand fiber - Bubbler 75 strand fiber - Spillway Light Bar 45 ft. fiber tail

More information

TOWN of CHEEKTOWAGA Permit Application for Swimming Pools, Hot Tubs, or Personal Spas

TOWN of CHEEKTOWAGA Permit Application for Swimming Pools, Hot Tubs, or Personal Spas Permit Application for Swimming Pools, Hot Tubs, or Personal Spas / 20 - Date of Application Received By Permit No. APPLICANT to COMPLETE the PINK PORTION! ( ) ( ). Applicant s Name Daytime Phone No. Cell

More information

COUNTER CURRENT UNIT. Instruction Manual

COUNTER CURRENT UNIT. Instruction Manual COUNTER CURRENT UNIT Instruction Manual 1 Introduction: Congratulations on your purchase of a new Certikin counter current swimming unit. This unit has been developed and built by qualified personnel especially

More information

RANGER PROP BUILDING INSTRUCTIONS & PHOTOS

RANGER PROP BUILDING INSTRUCTIONS & PHOTOS RANGER PROP BUILDING INSTRUCTIONS & PHOTOS Science under the ice Ice sheet At the international competition, the science under the ice product demonstration will take place under an actual sheet of ice.

More information

Perched Box Caisson Overview. January 2014

Perched Box Caisson Overview. January 2014 Perched Box Caisson Overview January 2014 Why perched box caissons? Perched box caissons are used to construct the portion of the river piers that will support the steel arch spans Construction can occur

More information

NAVIGATOR PROP BUILDING INSTRUCTIONS & PHOTOS

NAVIGATOR PROP BUILDING INSTRUCTIONS & PHOTOS NAVIGATOR PROP BUILDING INSTRUCTIONS & PHOTOS Science under the ice Ice sheet At regional competitions the ice is simulated by 8 ft x 4 ft ½-inch foam sheeting (Home Depot part #703990 [in store only],

More information

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines. Dry Hydrants What is a Dry Hydrant? A dry hydrant is a non-pressurized pipe system permanently installed in existing lakes, ponds and streams that provides a suction supply of water to a fire department

More information

SEries 29 Hydrant valves installation, operation & maintenance manual

SEries 29 Hydrant valves installation, operation & maintenance manual Instruction for use Thank you for selecting an AVK product. With correct use, it will give long and reliable service. This manual has been prepared to assist you install, operate and maintain the valve

More information

W A S T E W A T E R T R E A T M E N T S Y S T E M S

W A S T E W A T E R T R E A T M E N T S Y S T E M S W A S T E W A T E R T R E A T M E N T S Y S T E M S PROCEDURES FOR ASSEMBLY AND INSTALLATION A Division of Consolidated Trmt Systems, Inc. 1501 Commerce Center Drive Franklin, OH 45005 Tel: 937-746-2727

More information

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual LoneStar Fiberglass Pools Do-It-Yourself Installation Manual Chris 1/3/2008 Do-It-Yourself The installation of a LoneStar Fiberglass pool is a much simpler task than most people think. What is important

More information

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Connection Ends : Min Temperature : Max Temperature : DN 50 to 200 Flanged ISO PN 10/16 ( ISO PN16 for DN200 ) 0 C + 50 C Max Pressure : 16 Bars Specifications : Tangential type Dry dial Magnetic

More information

SPA WORLD. Pre- delivery Guide

SPA WORLD. Pre- delivery Guide SPA WORLD Pre- delivery Guide HELLO! This document is designed to provide all the information you need to ensure the smooth delivery and installation of your spa or swim spa. Please read it carefully and

More information

FLANGES, TEES AND CROSSES, SPOOLS AND ADAPTERS. Sara Sae

FLANGES, TEES AND CROSSES, SPOOLS AND ADAPTERS. Sara Sae FLANGES, TEES AND CROSSES, SPOOLS AND ADAPTERS Sara Sae Quality and Innovation Products Catalog Spools and Adapters Sara manufactures a wide range of Spools and Adapter Flanges conforming to API-16 A and

More information

SWIMMING POOL PERMITS ARE ABOUT HEALTH AND SAFETY

SWIMMING POOL PERMITS ARE ABOUT HEALTH AND SAFETY SWIMMING POOL PERMITS ARE ABOUT HEALTH AND SAFETY Swimming Pool Booklet Washington County, Maryland Published 2004 Revised 03/10/05 Revised 02/10/06 Department of Permits & Inspections 80 West Baltimore

More information

Agpro. Flush Valves TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE

Agpro. Flush Valves TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE www.agprousa.com Over 20 types to satisfy all your flushing needs. Agpro Flush Valves are fully operational units designed for one purpose, flushing

More information

PVC DWV FITTINGS PVC-0312 MARCH 2012 SUPERCEDES PVC-0112 ASTM D2665

PVC DWV FITTINGS PVC-0312 MARCH 2012 SUPERCEDES PVC-0112 ASTM D2665 PVC DWV FITTINGS PVC-0312 MARCH 2012 SUPERCEDES PVC-0112 ASTM D2665 COUPLING (Hub x Hub) 434043 1 1/4 50 10200 9.04 431130 1 1/2 100 10800 2.04 431148 2 75 5400 2.66 431155 3 50 1500 9.16 431163 4 35

More information

EPOXY FITTINGS DIMENSIONS

EPOXY FITTINGS DIMENSIONS Bulletin No. A150 May 1, 2004 EPOXY FITTINGS DIMENSIONS 2"-16" GREEN THREAD fittings may be used with GREEN THREAD and RED THREAD II piping. Refer to Chemical Resistance Guide, Bulletin No. E5615, for

More information

150 X 93 / 381 cm x cm* / cm* 1,489 US gallons / 5,635 Liters. 14,403lbs / 6,535 Kg lbs / 900 Kg. * +/- tolerance of 1/4

150 X 93 / 381 cm x cm* / cm* 1,489 US gallons / 5,635 Liters. 14,403lbs / 6,535 Kg lbs / 900 Kg. * +/- tolerance of 1/4 150 X 93 / 381 cm x 236.2 cm* * +/- tolerance of 1/4 48.75 / 123.83 cm* 1,489 US gallons / 5,635 Liters 14,403lbs / 6,535 Kg 1984 lbs / 900 Kg 46 1/4in ±3/4in (117.48cm ±1.91cm) Height of Swim Spa

More information

LASCO Schedule 40 PVC Fittings

LASCO Schedule 40 PVC Fittings LASCO Schedule 40 PVC Fittings A technical leader for over 65 years, LASCO fittings are relied upon worldwide and hold a reputation for quality products, innovation and technical leadership. Product Range

More information

ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL

ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL AFTER MARCH 1, 2012 ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL 400.1 Description. This item shall govern for all excavation required for the construction of all structures, except pipe or box sewers for

More information

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Color Light Streams Lighted Super Bubbler Kit Gunite CLSSBK SAVE THESE INSTRUCTIONS! SR Smith Color Light Streams Lighted Super Bubbler is a very simple device to provide lighted water for small fountains

More information

Office Use Only Fee Paid

Office Use Only Fee Paid WASHOE COUNTY HEALTH DISTRICT ENVIRONMENTAL HEALTH SERVICES DIVISION 1001 East Ninth Street PO Box 11130 Reno, Nevada 89520 Telephone (775) 328-2434 Fax (775) 328-6176 www.washoecounty.us/health APPLICATION

More information

Waterblade Installation Manual

Waterblade Installation Manual Waterblade Installation Manual The Waterblade is available in standard widths from 300cm to 2.4 metres. This unit must be installed according to these instructions; otherwise the warranty may be void.

More information

Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC Phone: Fax:

Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC Phone: Fax: Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC 28092 Phone: 704-736-8426 Fax: 704-736-8427 APPLICATION FOR APPROVAL TO CONSTRUCT OR RENOVATE A PUBLIC SWIMMING

More information

SHEER DESCENT & WATERFALL SPILLWAYS

SHEER DESCENT & WATERFALL SPILLWAYS Calculating Required Flowrates for Clearpond Sheer Descent Spillways 1. Determine how long your unit is. 2. Measure how high it is above water level. 3. Decide on an approximate projection between 100mm

More information

174 x 93 / cm x cm / cm US gallons / 6563 L. 16,766 lbs / 7,607 Kg. 2,302 lbs / 1,044 Kg

174 x 93 / cm x cm / cm US gallons / 6563 L. 16,766 lbs / 7,607 Kg. 2,302 lbs / 1,044 Kg 174 x 93 / 441.96 cm x 236.22 cm 48.75 / 123.83 cm 1727 US gallons / 6563 L 16,766 lbs / 7,607 Kg 2,302 lbs / 1,044 Kg 46 1/4in ±3/4in (117.48cm ±1.91cm) Height Swim Spa Acrylic Lip 48.75in ±1/2in

More information

Jet Swim Installation instruction

Jet Swim Installation instruction Jet Swim 2000 Jet Swim 2000 Liner pool 1. Remove the stainless steel front plate and cut out the pool wall according to the hole pattern. The center of the Jet Swim housing must be a minimum of 170 mm

More information

ROUND ASSEMBLY. Positioning

ROUND ASSEMBLY. Positioning ROUND ASSEMBLY Positioning To ensure maximum enjoyment and efficiency, consider the following steps when selecting the desired location of you pool. Select a location that receives maximum sunlight for

More information

SWIMMING POOL, SPAS, HOT TUB REQUIREMENTS AND GUIDELINES (Updated 3/2018)

SWIMMING POOL, SPAS, HOT TUB REQUIREMENTS AND GUIDELINES (Updated 3/2018) SWIMMING POOL, SPAS, HOT TUB REQUIREMENTS AND GUIDELINES (Updated 3/2018) POOL/SPA CHECKLIST Submittal of two (2) sets of plans is required for permit issuance. Obtain approval from the Planning/Zoning

More information

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS City of Redding 777 Cypress Avenue Redding CA 96001 Telephone: (530) 225-4013 FAX: (530) 225-4360 A Swimming Pool is any body of water 18 inches

More information

KlassikDrain Section K200/K300 ACO DRAIN. Introduction Pgs 1-13 Selecting the right product

KlassikDrain Section K200/K300 ACO DRAIN.  Introduction Pgs 1-13 Selecting the right product AO DRAIN Introduction Pgs - Selecting the right product KlassikDrain Pgs 4-, 54-6 General purpose trench drain Part - K00, K50 & Bricklslot KlassikDrain Pgs 4-5 General purpose trench drain Part - K00/K00

More information

220 / 93 / 558 / 236 cm / cm US gallons / 9038 L. 22,948 lbs / 10,412 Kg lbs / 1374 Kg

220 / 93 / 558 / 236 cm / cm US gallons / 9038 L. 22,948 lbs / 10,412 Kg lbs / 1374 Kg 220 / 93 / 558 / 236 cm 52.75 / 133.99 cm 2378 US gallons / 9038 L 22,948 lbs / 10,412 Kg 3028 lbs / 1374 Kg 50in ±3/4 in (127.00 cm ±1.91cm) Height Swim Spa Acrylic Lip 52 3/4 in ±1/2 in (133.99

More information

Siting and Installation Manual

Siting and Installation Manual Siting and Installation Manual B-Series Advanced Wastewater Treatment Units Revolutionary Waste Treatment Advanced Wastewater Treatment Units (ATUs) that deliver an unsurpassed performance at an unbeatable

More information

186 x 93 / 473 cm x cm / cm. 1,944 US gallons / 7,358 L. 18,677 lbs / 8,474 Kg. 2,460 lbs / 1,116 Kg

186 x 93 / 473 cm x cm / cm. 1,944 US gallons / 7,358 L. 18,677 lbs / 8,474 Kg. 2,460 lbs / 1,116 Kg 186 x 93 / 473 cm x 236.2 cm 48.75 / 123.83 cm 1,944 US gallons / 7,358 L 18,677 lbs / 8,474 Kg 2,460 lbs / 1,116 Kg 46 1/4in ±3/4in (117.48cm ±1.91cm) Height Swim Spa Acrylic Lip 48.75in ±1/2in (123.83

More information

CITY OF ROSEVILLE DESIGN AND CONSTRUCTION DETAILS

CITY OF ROSEVILLE DESIGN AND CONSTRUCTION DETAILS CITY OF ROSEVILLE DESIGN AND CONSTRUCTION DETAILS Trench Backfill Utility Trench Paving Backfill and Embedment TB 1 HDPE, SRHDPE & PVC Storm Drain Pipe Only (Nonrigid) Bedding and Backfill TB2 Deep Cut

More information

Table of Contents. We also carry a wide range of supplemental products for splash pad systems and pools.

Table of Contents. We also carry a wide range of supplemental products for splash pad systems and pools. Table of Contents WATER UMBRELLA 4 WATER MUSHROOM (40 ) 5 WATER MUSHROOM (30 ) 6 FLOWER SHOWER - 1 7 FLOWER SHOWER - 2 8 FLOWER SHOWER - 3 9 FLOWER SHOWER - 4 10 FIRE HYDRANT SOAKER 11 RAIN STICK 12 RAINY

More information

Planning Backyard Vacations Everyday

Planning Backyard Vacations Everyday Your Local Platinum Pool Dealer NOTICE: This brochure is for illustrative purposes only. The fabricator makes only those representations which are stated in its written warranties. Any other representations,

More information

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET Sect. 106-748, City Code of Ordinances: Regulations are applicable to both above and inground swimming pools, spas and hot tubs. POOL PLACEMENT Measurement

More information

City of Naperville Transportation, Engineering & Development (T.E.D.) Services Team

City of Naperville Transportation, Engineering & Development (T.E.D.) Services Team City of Naperville Transportation, Engineering & Development (T.E.D.) Services Team PERMIT APPLICATION INFORMATION for SWIMMING POOLS, SPAS AND HOT TUBS THE FOLLOWING MUST BE INCLUDED WITH EVERY APPLICATION

More information

SCOUT PROP BUILDING INSTRUCTIONS & PHOTOS

SCOUT PROP BUILDING INSTRUCTIONS & PHOTOS SCOUT PROP BUILDING INSTRUCTIONS & PHOTOS Companies should be aware that tolerances in lengths of pipe and length of pipe inserted into joints can change the overall dimensions of product demonstration

More information

RESIDENTIAL SWIMMING POOL REQUIREMENTS

RESIDENTIAL SWIMMING POOL REQUIREMENTS CITY OF GRANDVIEW / BUILDING SERVICES 1200 MAIN STREET, GRANDVIEW, MO 64030 PHONE: (816) 316-4817 FAX: (816) 316-4809 WWW.GRANDVIEW.ORG RESIDENTIAL SWIMMING POOL REQUIREMENTS Community Development Department

More information

AFL Industries, 1101 West 13 th St, Riviera Beach, FL 33404 PHONE: (561) 848-1826 FAX: (561) 848-9454 E-Mail: Sales@aflindustries.com AFL-STD MODEL OSV-4 SS INSTALLATION, OPERATION & MAINTENANCE BROCHURE

More information

POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS

POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS SECTION AG101 - GENERAL POOL BARRIER AMENDMENTS & GUIDELINES: APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBS AG101.1 General. The requirements of this appendix shall apply to the design and construction

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

210 x 93 / cm x cm / cm US gallons / 8259 Litres. 20,830 lbs / 9,451 Kg. 2,627 lbs / 1,192 Kg

210 x 93 / cm x cm / cm US gallons / 8259 Litres. 20,830 lbs / 9,451 Kg. 2,627 lbs / 1,192 Kg 210 x 93 / 533.40 cm x 236.22 cm 48.75 / 123.83 cm 2182 US gallons / 8259 Litres 20,830 lbs / 9,451 Kg 2,627 lbs / 1,192 Kg 46 1/4in ±3/4in (117.48cm ±1.91cm) Height of Swim Spa Acrylic Lip 48.75in

More information

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP 25503 SERIES TABLE OF CONTENTS A. PRODUCT OVERVIEW A.1 SPECIFICATIONS A. PRODUCT OVERVIEW... 3 A.1 Specifications A.2 Packing

More information

FINALIZATION OF THE HAND DUG WELL. Version : April 2009 Published by : Foundation Connect International Autors : Henk Holtslag & John de Wolf

FINALIZATION OF THE HAND DUG WELL. Version : April 2009 Published by : Foundation Connect International Autors : Henk Holtslag & John de Wolf ST 1.6 FINALIZATION OF THE HAND DUG WELL Version : April 2009 Published by : Foundation Connect International Autors : Henk Holtslag & John de Wolf Disclaimer This manual is part of the main manual, named

More information

WATERFALLS DECK JETS SCONCES. Waterfall, - Cut the waterfall notch in the inner edge of the bond beam at the stee tive cover nd protec a

WATERFALLS DECK JETS SCONCES. Waterfall, - Cut the waterfall notch in the inner edge of the bond beam at the stee tive cover nd protec a Logo NAturAl Wonders WATERFALLS DECK JETS SCONCES Deck Jet Waterfall, 1" Lip Interchangeable Nozzle! - Cut the waterfall notch in the inner edge of the bond beam at the stee l offs et. tive cover nd protec

More information

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS Wastewater combination air valve in Mod. SCS The air valve guarantees the proper operation of sewage/industrial lines allowing the entrance of large quantity of air in case of pipe bursting or draining,

More information

*A Certificate of Survey for the property may be on file at City Hall if the house was built after 1984.

*A Certificate of Survey for the property may be on file at City Hall if the house was built after 1984. Swimming Pools ** Permits are required for pools having a water surface area exceeding 100 square feet ** Permits are required for pools having a water surface area exceeding 100 square feet (11-3-3/8

More information

KlassikDrain Section. Technical Handbook and Product Catalog. General purpose trench drainage

KlassikDrain Section. Technical Handbook and Product Catalog. General purpose trench drainage Technical Handbook and Product Catalog Surface Drainage 6 Surface drainage options 8 Product selection 10 Trench drain hydraulics 16 Loadings 22 Material data 24 End user requirements Standard Products

More information

Swimming Pool Permits are About Health and Safety

Swimming Pool Permits are About Health and Safety Swimming Pool Permits are About Health and Safety Swimming Pool Booklet Published 2004 Revised 04/06/16 Permitting Department 80 W. Baltimore Street Hagerstown, Md. 21740 240-313-2460 (F) 240-313-2461

More information

PAGE (Rev. A - 06/17)

PAGE (Rev. A - 06/17) Owners Manual Models 4420BF1UDBFR* and 4420BF1LDBFR* Bi-Level Tubular Bottle Filler Fountain with Pet Fountain and Sanitary Freeze Resistant Triple Valve Control Assembly MODEL (LK)4420BF1UDBFR MODEL (LK)4420BF1LDBFR

More information

Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS

Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS This brochure is designed to provide step-by-step instructional assistance to the individual who wishes to install a shallow water well system for residential

More information

NAVIGATOR Product demonstration prop building instructions

NAVIGATOR Product demonstration prop building instructions NAVIGATOR Product demonstration prop building instructions Regional competitions may build product demonstration props out of materials other than PVC pipe. Your regional coordinator will inform you of

More information

New England Municipal Building Officials Preventing Drowning and Suction Entrapment through Code Compliance

New England Municipal Building Officials Preventing Drowning and Suction Entrapment through Code Compliance New England Municipal Building Officials Preventing Drowning and Suction Entrapment through Code Compliance 2009 International Family of Codes Swimming Pools and Spas 2009 International Building Code 2009

More information

174 x 93 / cm x cm / cm US gallons / 6563 L. 16,766 lbs / 7,607 Kg. 2,302 lbs / 1,044 Kg

174 x 93 / cm x cm / cm US gallons / 6563 L. 16,766 lbs / 7,607 Kg. 2,302 lbs / 1,044 Kg 174 x 93 / 441.96 cm x 236.22 cm 48.75 / 123.83 cm 1727 US gallons / 6563 L 16,766 lbs / 7,607 Kg 2,302 lbs / 1,044 Kg 46 1/4in ±3/4in (117.48cm ±1.91cm) Height of Swim Spa Acrylic Lip 48.75in ±1/2in

More information

6900 Professional Parkway East, Sarasota, FL Phone Fax Certificate of Authorization #43 FL Lic.

6900 Professional Parkway East, Sarasota, FL Phone Fax Certificate of Authorization #43 FL Lic. 6900 Professional Parkway East, Sarasota, FL 34240 Phone 941-907-6900 Fax 941-907-6910 Certificate of Authorization #43 FL Lic. # LC-C000170 www.stantec.com PLANT SCHEDULE NOTE: THIS PLANT

More information

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS MIDDLESEX COUNTY COLLEGE EDISON, NJ 08818 LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS The College is soliciting bids to award a Local Supplier Blanket Order agreement for the purchase of supplies for the

More information

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED

More information

REQUEST FOR PROPOSAL FOR WATERPROOFING STRUCTURAL ENGINEERING

REQUEST FOR PROPOSAL FOR WATERPROOFING STRUCTURAL ENGINEERING DATE: November 13, 2018 REQUEST FOR PROPOSAL FOR WATERPROOFING STRUCTURAL ENGINEERING PROJECT: OWNER: Corbett Pool Renovation Office of the University Engineer NC A&T State University 1601 East Market

More information

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual STOP! Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY

More information

FOAM FRACTIONATORS. Also Known As. Phoam Phraxtionators Protein Skimmers Air Strippers

FOAM FRACTIONATORS. Also Known As. Phoam Phraxtionators Protein Skimmers Air Strippers FOAM FRACTIONATORS Also Known As Phoam Phraxtionators Protein Skimmers Air Strippers Do you have bubbles on your water surface? Do you have algae problems, either floating or string? Do you have water

More information

RIVERFLOW PUMP INSTALLATION GUIDE

RIVERFLOW PUMP INSTALLATION GUIDE 2-0 3-8 By: By: TABLE OF CONTENTS 3 4 20 21 22 5 6 7 8 9 14 15 16 17 18 19 RIVERFLOW SYSTEM OVERVIEW COMPONENTS CHECKLIST & ACTIVATION MOTOR MOUNT COVER CONTRACTOR S FINAL CHECKLIST PLUMBING INSTALLATION

More information

ARCHITECTURAL GUIDELINES ONE-PIECE COMMERCIAL

ARCHITECTURAL GUIDELINES ONE-PIECE COMMERCIAL ARCHITECTURAL GUIDELINES ONE-PIECE COMMERCIAL Architect Guidelines for SwimEx Installation of 500OT DW, 500OT, and 400OT General Layout Call SwimEx at 800-877-7946 to receive AutoCad Drawings of the SwimEx

More information

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN CLACKAMAS COUNTY COMMUNITY HEALTH DIVISION ENVIRONMENT & HEALTH SERVICES APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN APPLICATION IS HEREBY MADE

More information

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST Pool Name: Address: Contractor: Phone: Number of Pools Applied for: GENERAL INFORMATION Plan review paid Pool Piping plan stamped by Design Professional.

More information

ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL

ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL Architect Installation Guidelines for Four-Piece Residential Installations GENERAL LAYOUT Call SwimEx at 800-877-7946 to receive AutoCad Drawings of the

More information

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE NOTICE WARNING To Installers: Read and follow these instructions. Give these instructions to the facility owner to keep for future

More information

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions Jacuzzi J-CQ420 Cartridge Filter Installation and Operating Instructions IMPORTANT SAFETY PRECAUTIONS ATTENTION INSTALLER: This guide contains important information about the installation, operation and

More information

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE NOTICE WARNING To Installers: Read and follow these instructions. Give these instructions to the facility owner to keep for future

More information

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

SWIMMING POOL, SPA, & HOT TUB GUIDELINES SWIMMING POOL, SPA, & HOT TUB GUIDELINES A. Adopted construction codes and installation requirements 1. 2015 edition of the International Residential Code and Appendix Q, 2. 2014 edition of the National

More information

Pool Name Length Width Lineal Ft. Gallons Weight $ Price $

Pool Name Length Width Lineal Ft. Gallons Weight $ Price $ My Favorite Pool Builder, Inc. 1956 SW Nain Blvd, Lake City, Fl. 32025 Phone: 386-269-3304 Toll Free & Fax: 800-286-7929 Barrier Reef Pool Price List 2018 Sales Tax Included Installed at our location in

More information

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20806 A-20807 Adjustable General Information 2 Technical Data 3 Dimensions 4 Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

2010 STANDARD SPECIFICATIONS STANDARD DRAWINGS

2010 STANDARD SPECIFICATIONS STANDARD DRAWINGS CITY OF REDMOND, OREGON 2010 STANDARD SPECIFICATIONS STANDARD DRAWINGS TABLE OF CONTENTS SECTION 1 TRENCHES TITLE 1-1 Utility Trench 1-2 Water Line & Sewer Line Separation 1-3 RR X-ING Single/Joint Use

More information

PowerDrain Section S100K/S200K/S300K ACO DRAIN. Introduction Pgs 1-13 Selecting the right product

PowerDrain Section S100K/S200K/S300K ACO DRAIN.   Introduction Pgs 1-13 Selecting the right product 1 Introduction Pgs 1-13 Selecting the right product KlassikDrain Pgs 14-33, 54-61 General purpose trench drain Part 1 - K100, K50 & Bricklslot KlassikDrain Pgs 34-53 General purpose trench drain Part 2

More information

RESIDENTIAL SWIMMING POOL

RESIDENTIAL SWIMMING POOL MAIL PICK-UP A. SWIMMING POOL PERMIT TYPE ABOVE-GROUND POOL B. IDENTIFICATION PROJECT LOCATION (ADDRESS): NORTH WHITEHALL TOWNSHIP 3256 LEVANS ROAD, COPLAY, PA 18037 610-799-3411 610-799-9629 FAX www.northwhitehall.org

More information

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/2) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 02 PROJECT : QUANTITY : 03 LOCATION : SERVICE : FOAM SYSTEM 04 05 CODE & STANDARDS

More information

Installation Guide For Spillways & LED Light Bars

Installation Guide For Spillways & LED Light Bars Installation Guide For Spillways & LED Light Bars *A pdf copy can be obtained via www.iearth.com.au/downloads 1 TABLE OF CONTENTS A1. Size Availability.. Page 3 B1. Type of Spillway Effects. Page 3 1.

More information

ARCHITECTURAL GUIDELINES 1000 S

ARCHITECTURAL GUIDELINES 1000 S ARCHITECTURAL GUIDELINES 1000 S Architect Guidelines for SwimEx Installation Model 1000S GENERAL LAYOUT Call SwimEx at 800-877-7946 to receive AutoCad Drawings of the SwimEx Model that you will be installing.

More information

ENDLESS POOLS FITNESS SYSTEMS. Product Announcement 50Hz May 2017

ENDLESS POOLS FITNESS SYSTEMS. Product Announcement 50Hz May 2017 ENDLESS POOLS FITNESS SYSTEMS Product Announcement 50Hz May 2017 1 EXCITING ENDLESS POOLS FITNESS SYSTEMS UPDATES We are excited to tell you about several new products that will help you attract more consumers

More information

POP UP ANCHOR. Part Number Spectrum Lane ~ Missoula MT ~

POP UP ANCHOR. Part Number Spectrum Lane ~ Missoula MT ~ POP UP ANCHOR Part Number 153169 7100 Spectrum Lane ~ Missoula MT 59808 800.791.8056 ~ www.spectrumproducts.com You have purchased a Spectrum Products Pop Up Lane Rope Anchor. Providing the unit is installed

More information