A Novel Device for Measuring Fluctuations in Stride Intervals of Human Gait

Size: px
Start display at page:

Download "A Novel Device for Measuring Fluctuations in Stride Intervals of Human Gait"

Transcription

1 Bulletin of the Osaka Medical College 48 1, , Original Article A Novel Device for Measuring Fluctuations in Stride Intervals of Human Gait Manabu MIYAMOTO and Masahiko SHINDO 1 First Department of Physiology, Osaka Medical College, Takatsuki, Osaka, , Japan Key Words : Fluctuation, Stride intervals, 1/f, RS232C, Self-correlation ABSTRACT Fluctuations in stride-to-stride intervals have been already pointed out. However, further studies of this issue have not progressed in comparison with that of heartbeat because of difficulties both in measuring and in analyzing bilateral walking rhythms. These data had been usually recorded on an analog recorder. Subsequently, such an ambulatory recording machine sometimes influences original fluctuations. We developed a novel device for direct measurement of stride intervals of human gait to investigate gait disturbance caused by many central nervous system disorders. Our system used digital processing with an RS232C terminal. The flat and flexible tape switches are taped to both heels. A threshold of the force required for switching is adjustable. This system is not so expensive and is portable. The measurement is possible even at great distance from a subject via using a radio. Protocols for data collection can be changed. Our spectrum analysis showed long-range correlation. The slopes with respect to power spectrum and frequency in log-log plot are (n=5) for right foot and (n=5) for left foot. These results suggest that stride intervals showed self-correlation, and the analysis of the synchronous mechanism for each pace of the right and left cycles is expected to develop. The accuracy of the sampling time was also examined. The measurement at a sampling rate of 10msec is recommended. INTRODUCTION Since fractal fluctuations in heartbeat intervals have been reported (GOLDBERGER et al, 1990), it has been widely recognized that examples of fractal are abundant in nature. Under healthy conditions, functional oscillations, such as respiratory rhythm and electroencephalogram in addition to heartbeat intervals, also show the presence of long-range self-similar correlations. For example, the heartbeat interval at any time depended on that at previous time, and this dependence decayed in a scale-free (fractal-like) power-low fashion. However, the fractal dynamics disappeared in the patients with heart diseases. (AKSELROD et al, 1981). Following this finding, the spectrum analysis of heartbeats advanced greatly and was applied in a clinical setting. On the other hand, fluctuations were discovered in human gait as well. The gaits of healthy young adults have been reported to be scale-free with long-range correlations. The breakdown of longrange correlations occurred during metronomicallypaced walking was investigated by Hausdorff (HAUSDORFF et al, 2001). He also reported the effects of advanced age and Huntington's disease, a 19

2 20 M. MIYAMOTO, M. SHINDO neurodegenerative disorder of the central nervous system on stride interval correlations. Further research on the phenomena on stride interval correlations has not progressed in comparison with that of heartbeat very much, because of difficulties in measuring stride intervals. Moreover, left and right rhythms complicate measurements. Various methods of measuring stride intervals have been attempted previously. Stride interval was defined as the time between the heel strike of one foot and the next heel strike of the same foot. To measure the stride interval, usually force-sensitive switching devices are taped beneath both heels. Electric changes evoked by contact of heels are usually recorded in the magnetic tape in analog. Then, the recorded gait signals were digitized with an AD converter, and the intervals between heel strikes were computed. Because the noise may affect the results, the analogue-type recording machine was recommended to be able to take data at a rate faster than 416Hz (HAUSDORFF, 1992). It had been impossible for direct digital-data processing. However, with the development of computer, it became possible to record stride intervals precisely and to digitize data directly. In this study, we developed a novel measurement device by assembling the latest parts and made the new software for analysis, and examined its performance. METHOD 1 Devices attached to a subject. The tape switch (151-BBW, Tape Switch Japan Company) was used as the sensor to capture the times of landing of heels. The size of the tape part was adjusted to 14.3mm 620mm 1.4mm. They were covered by paraffin film (PARAFILM, American National Can Company) and attached to the right and left heels using a 2.5 cm-wide adhesive tape (3M Company) as shown in Figure 1. Several 15 cm-long stripes of the tape were used to fix the tape switch on each foot as been partially superposed upon each other. We confirmed that there was not drift of the sensor in walk. Each lead of the switch was connected to the wireless communication device with leads of 1mlong. We used the wireless network adaptor (WNA-RS, I-ODATA Corporation), which was a 2.4GHz spectrum diffusion-type: Direct Sequence Spread Spectrum (DS-SS). Serial communication at a maximum communication speed of 115.2kbps is possible by radio. The terminals of the right tape switch were connected to 6-pin and the ground, and those of the left tape to 8-pin and the ground with the Recommend Standard number 232 C (RS232C) standard. Then, the setup of the wireless network adaptor on the subject is set in the terminal adapter (TA) mode; therefore, RS232C was connected in the cross-wiring mode. This adapter driven by alkali dry battery in series (6.4V) was fixed the subject on the lumbar region with the band and pocket.(figure 2) 2 Hardware in the data-receiving end. (Data incorporation end) Another wireless network adaptor of WNA-RS was used as the wireless communication hardware on the data-receiving end. A data incorporation computer is a Notebook conformer (IBM ThinkPad X22, IBM Japan; CPU: Pentium III, 533MHz). A Universal Serial Bus (USB) Serial adapter (URS-03, PLANECS COMMUNICATIONS CORPO- Fig. 1 Installation of the tape switches to both sole. Fig. 2 Apparatus for measuring stride-to-stride intervals in a human gait. Data-sending devices were composed of the switches and the wireless network adaptor. Data-receiving notebook computer was equipped with the other wireless network adaptor and USB Serial adaptor. 20 Bulletin of the Osaka Medical College 48 1, , 2002

3 A Novel Device for Measuring Fluctuations in Stride Intervals of Human Gait 21 RATION) connects between WNA-RS on the datareceiving end and the USB terminal. The other end of the D-sub 9 terminal was connected to the RS232C terminal (D-sub 9 pin-female) of the wireless network adapter on the receiving side. This adapter was set in the personal computer (PC) mode. (Figure 2) The program for data incorporation was developed using Microsoft Visual Basic 6.0 using timer function. The communication conditions of this RS232C were bit rate, 9600bps; parity, N; data length, 8; stop bit, 1. The graphical user interface was adopted in the program for sampling. A sampling rate (a generation time of the timer function) could be set in the text box. This program was compiled and used as execute file. Its counter increased by 1 for every sampling, and the total number of this counter was substituted for time. The counter numbers at moments when the switching device became on (1) from off (0) were recorded on each side. Data were stored in using the ASCII format when a directory and a file name for storage was specified in the text box. The storage format consisted of the counter value of the left switch, tab break, counter value of the right switch and return as terminator. 3 Study of the accuracy of sampling rate. The accuracy of a sampling rate in this device was also studied. The intervals of function calls for timer can be changed by the context in the text box. The program started in the setup condition. At the moment when 1000 counts were reached, the total elapsed time was obtained using the calling system time function. breaks. Samples consisted of 128 points from the start of walkings, which were analyzed using a mathematical software (Mathcad, Mathsoft Corporation). The command of "pspectrum" as a built-in function in Mathcad was used to calculate the power spectrum of these data with the assistance of discrete FFT. The pspectrum (x, n, r, w) indicates as the follows, x is a signal vector, n is an integer, and 1 n length(x) is a segment of the input signal. r (0 r 1) is the partial overlap between segments, and w is the index that specifies the window handling function. Here, n=3, r=0.1 and the Hanning window handling was used. 4-1 Representative stride interval time courses Stride interval time course graph and their power spectra, were obtained for a sampling rate of 100msec, 50msec and 10msec and self-correlation functions were calculated. The appropriate sampling time and the fluctuation pattern of stride-to-stride intervals was determined. 4-2 Estimation of number of power The exponent of power with respect to the power spectrum and frequency was then estimated in a log-log plot in the case of the sampling time at 10msec. Table 1 Sampling time and total time taken for 1000 counts. 4 Measurement of stride-to-stride time intervals in volunteers Five healthy men without any history of neuromusculoskeletal disorders especially no aliment aberration of lower extremities such as genu varum or genu valgum and no medical history of sprains, participated in this study. The mean age was 43 years old (range 34-52yr). The mean height of the subjects was 1.68 m and the mean weight was 62.2 kg. The subjects were instructed to walk continuously on a level ground at a usual self-determined rate. Switching devices are attached to both of their heels. When they walked naturally wearing an ordinary pair of shoes, bilateral stride-to-stride intervals were simultaneously measured. The number of heel strikes counters for both sides was recorded in the text file with "tab" Bulletin of the Osaka Medical College 48 1, ,

4 22 M. MIYAMOTO, M. SHINDO RESULTS For the count up to 1000, the total time was measured for sampling times of 100msec, 90msec, 80msec, 70msec, 60msec, 50msec, 40msec, 30msec, 20msec, 10msec, 9msec, 8msec, 7msec, 6msec, 5msec, 4msec, 3msec, 2msec and 1msec. Results of these trial measurements are shown in Table 1. Sampling times showed accurate count times for a total time of more than 10msec. Even when the sampling times became shorter than 10msec, the total count times in the trial was the same as 10sec. (Table 1) The individual time courses of stride intervals for both feet in 3 cases out of the five subjects were shown in Figure 3. Their power spectra were also plotted in Figure 4. The logarithm of power was shown in the y axis and the logarithm of frequency was shown in the x axis. The slope was estimated by the least square fitting method. The slopes were (n=5) for the right foot and (n=5) for the left foot. That is, since the stride fluctuated showing the character of 1/f noise, the logarithm power was inversely proportional to the logarithm frequency with the slopes of near 1. Furthermore, these self-correlation functions were characteristic and coincide each another as shown in Figure 4. Figures 5-a and b showed the stride interval time courses taken at a sampling time of 50msec and their power spectra. Furthermore, Figures 5-c and d showed the time courses at a sampling time of 100msec; fluctuations could be detected even at this sampling time. However, it was recommended to analyze at a sampling time of less than 50msec, in particular, at especially 10msec. Fig. 3 Time courses of stride-to-stride intervals of actual gaits. Each scale for the right or left foot was indicated on each side of the figures. DISCUSSION Various phenomena with fluctuations in the living body have been reported in recent years (GOLDBERGER et al, 1990). Fluctuation in a gait cycle was already discovered (HAUSDORFF et al, 1995). Moreover, there are left and right rhythms in a walk, and the importance of research on the mutual relationship of left-right fluctuations was also pointed out. However, these studies have not progressed as much as compared with those of heartbeat because of difficulty in many factors for measuring the stride-to-stride period in locomotion. The conventional method of measuring the times taken for infinite steps is insufficient. In order to measure fluctuations during walking, we must measure the stride-to-stride intervals directly. In this paper, we developed a novel device for direct measurement of stride intervals of human gait to investigate gait disturbance caused by many central nervous system disorders. Various devices for measuring walking cycles have been developed previously. However, the force plate is only applicable to measurement of a few steps possible. On the other hand, both the built-in floor type (CROUSE et al, 1987) and the measuring-walkway (GARDNER et al, 1975) are expensive. Adjustment of the threshold force required for switching is difficult in an insole-type device (GIFFORD et al, 1987). Foot switch devices 22 Bulletin of the Osaka Medical College 48 1, , 2002

5 A Novel Device for Measuring Fluctuations in Stride Intervals of Human Gait 23 Fig. 4 Power spectrum analysis (Relationship between logarithm of power and logarithm of frequency) and Self-correlation function are more convenient but data intakes are usually in analog. (ALEXANDERl et al, 1990; LIGGINS Abet al, 1991; MINNS RJ et al, 1982; ROSS JD et al, 1987; WINTER DA et al, 1972) Intermediate recording into a magnetic tape with an analog is not satisfactorily performed, and the recording machine sometimes affects the data. On the other hand, our measure system for stride intervals by digital type with application of the RS232C standard can digitalize time intervals directly at the time of sampling. A maximum resolution at a sampling time of 10msec can be attained. Each basic command is executed in synchrony with the clock of a computer in the order of 500MHz. Many factors such as interruptions may stagger the sampling time, but a shift in time is negligible in the order of millisecond. We can measure time intervals precisely using our device without any mechanical fluctuations. Furthermore, the followings are its features. The flat and flexible tape switches are used and attached to both heels. The threshold force required for switching on the device can be adjusted by choosing materials (2.2N in this cases). This system is not so expensive because its components are available in the market, and it is portable and its use is not restricted both by place and by condition. A person can obtain measurements at a distance via a radio. There is no problem with the subject wearing an ordinary pair of shoes. The subject is not restricted by wiring. Protocols for measurement can be changed when the program of the computer is changed. Signal processing can be carried out using the same computer as the receiver. However, there were some defects of this device. Didn't the place of the switch change in walk? Was fixation and fixative intensity of 3M tape sufficient? In anyway it was necessary to confirm that the places of the switches did not slip off after walk. Bulletin of the Osaka Medical College 48 1, ,

6 24 M. MIYAMOTO, M. SHINDO Fig. 5 a Time courses of stride intervals at a sampling time of 50msec b Power spectrum analysis c Time courses of stride intervals at a sampling time of 100msec d Power spectrum analysis Each scale axis for each foot was set on each side. Notice that their 0 line levels are different in right and left stride intervals. According to our unpublished data of simultaneous accelerometry, "on" of the switches were synchronized very well with the acceleration curve in walking direction. Spectrum analyses of fluctuations in stride intervals were performed. They had the characteristic of 1 / f fluctuation as shown by the linear relationship between the logarithmic power spectrum and logarithmic frequency. The slopes were (n=5) for the right side and (n=5) for the left side. It was suggested that stride intervals show chaos, and the analysis of the synchronous mechanism for both rhythms of the right and left is expected to develop. The accuracy of sampling time was also examined. The measurement at a sampling rate of 10msec is recommended. REFERENCES AKSELROD S, GORDON D, UBEL FA, SHANNON DC, BERGER AC and COHEN RJ: Power spectrum analysis of heart rate fluctuation: a quantitative probe of beat-to-beat cardiovascular control. Science 213, 220, 1981 ALEXANDER I, CHAO EY and JOHNSON KA: The assessment of dynamic foot-to-ground contact forces and plantar pressure distribution: a review of the revolution of current techniques and clinical applications. Foot Ankle 11, , 1990 CROUSE J, WALL JC and MARBLE AE: Measurement of the temporal and spatial parameters of gait using a microcomputer based system. J. Biomed. Engng 9, 64-68, 1987 GARDNER GM and MURRAY MP: A method of measuring the duration of foot-floor contact during walking. Phys. Ther. 11, , 1975 GIFFORD G and HUGHES JA: Gait analysis system in clinical practice. J. Biomed. Engng 5, , 1983 GOLDBERGER AL, RIGNEY DR and WEST BJ: Chaos and fractals in human physiology. Scientific American 262(2) 42-51, Bulletin of the Osaka Medical College 48 1, , 2002

7 A Novel Device for Measuring Fluctuations in Stride Intervals of Human Gait 25 HAUSEDORF JM, PENG C-K, LADIN Z, WEI Y and GOLDBERGER AL: Is walking a random walk? Evidence for long-range correlation in stride interval of human gait. Journal of Applied Physiology 78, 349, 1995 HAUSEDORF JM, ASHKENAZY Y, PENG C-K, IVANOV P, STANLEY E and GOLDBERGER AL: When human walking becomes random walking: fractal analysis and modeling of gait rhythm fluctuations. PHYSICA A 302, , 2001 LIGGINS AB and BOWKER P: A simple low cost footswitch. J. Biomed. Engng 13, 87-88, 1991 MINNS RJ: A conductive rubber footswitch design for gait analysis. J. Biomed. Engng 4, , 1982 ROSS JD and ASHMANN RB: A thin foot switch. J. Biomechanics 20, , 1987 WINTER DA, GREENLAW RK and HOBSON DA: A microswitch shoe for use in locomotion studies. J. Biomechanics, 5, , 1972 Bulletin of the Osaka Medical College 48 1, ,

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

Inter and intra-limb processes of gait control.

Inter and intra-limb processes of gait control. Inter and intra-limb processes of gait control. Simon B. Taylor, Rezaul K. Begg and Russell J. Best Biomechanics Unit, Centre for Rehabilitation, Exercise and Sport Science. Victoria University, Melbourne,

More information

The three steps for biomechanical assessment are the following: > Periodically verify the results and the efficacy of treatment

The three steps for biomechanical assessment are the following: > Periodically verify the results and the efficacy of treatment ENG After having carried out and saved a test, two reports are immediately available: > Gait/Run report: specific report for gait or running tests, with average values, standard deviation and variability

More information

Figure 1 betois (bending torsion insole system) system with five measuring points and A/D- converter.

Figure 1 betois (bending torsion insole system) system with five measuring points and A/D- converter. Bending and Torsional Moments - A new measuring system for gait analysis Nora Dawin & Annette Kerkhoff & Klaus Peikenkamp, University of Applied Sciences Münster, Germany Abstract The Laboratory of Biomechanics

More information

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output CONSOLE-320 Item 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output Table of contents 1. INTRODUCTION...2 1.1 Power supply...2 1.2 Connections...2 1.3

More information

RM-80 respiration monitor

RM-80 respiration monitor RM-80 respiration monitor User Manual September 18, 2015 0025-003M 950 North Hague Avenue Columbus, Ohio 43204-2121 USA Sales: sales@colinst.com Service: service@colinst.com Phone: (614) 276-0861 Fax:

More information

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel DTLS Manual This document contains proprietary information. Copyright 2015 Scientific Data Systems, Inc. All rights reserved. 1 Depth Tension

More information

KEM Scientific, Inc. Instruments for Science from Scientists

KEM Scientific, Inc. Instruments for Science from Scientists KEM Scientific, Inc. Instruments for Science from Scientists J-KEM Scientific, Inc. 6970 Olive Blvd. St. Louis, MO 63130 (314) 863-5536 Fax (314) 863-6070 E-Mail: jkem911@jkem.com Precision Vacuum Controller,

More information

Towards determining absolute velocity of freestyle swimming using 3-axis accelerometers

Towards determining absolute velocity of freestyle swimming using 3-axis accelerometers Towards determining absolute velocity of freestyle swimming using 3-axis accelerometers Author Stamm, Andy, Thiel, David, Burkett, Brendan, James, Daniel Published 2011 Journal Title Procedia Engineering

More information

The Influence of Load Carrying Modes on Gait variables of Healthy Indian Women

The Influence of Load Carrying Modes on Gait variables of Healthy Indian Women The Influence of Load Carrying Modes on Gait variables of Healthy Indian Women *Guha Thakurta A, Iqbal R and De A National Institute of Industrial Engineering, Powai, Vihar Lake, Mumbai-400087, India,

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

NIH Public Access Author Manuscript Gait Posture. Author manuscript; available in PMC 2009 May 1.

NIH Public Access Author Manuscript Gait Posture. Author manuscript; available in PMC 2009 May 1. NIH Public Access Author Manuscript Published in final edited form as: Gait Posture. 2008 May ; 27(4): 710 714. Two simple methods for determining gait events during treadmill and overground walking using

More information

GAIT ANALYSIS OF SUBJECTS WITH ANTERIOR CRUCIATE LIGAMENT RUPTURE USING MEDILOGIC SOLE PRESSURE DISTRIBUTION MEASUREMENT SYSTEM

GAIT ANALYSIS OF SUBJECTS WITH ANTERIOR CRUCIATE LIGAMENT RUPTURE USING MEDILOGIC SOLE PRESSURE DISTRIBUTION MEASUREMENT SYSTEM GAIT ANALYSIS OF SUBJECTS WITH ANTERIOR CRUCIATE LIGAMENT RUPTURE USING MEDILOGIC SOLE PRESSURE DISTRIBUTION MEASUREMENT SYSTEM D. Höftberger 1, A. Kozek 1, J. Langer 1, J. Obergruber 1 1 Fachhochschule

More information

Gait Analysis System. User Manual and Outcome parameters Patent WO2012/ A1

Gait Analysis System. User Manual and Outcome parameters Patent WO2012/ A1 Gait Analysis System User Manual and Outcome parameters Patent WO212/7855 A1 Thank you for purchasing our Gait Analysis Package. Gait Up s goal is to provide you with a user-friendly setup to measure accurately

More information

Ambulatory monitoring of gait quality with wearable inertial sensors

Ambulatory monitoring of gait quality with wearable inertial sensors Ambulatory monitoring of gait quality with wearable inertial sensors Dr. Philippe Terrier, PhD June 2016 Summary 1. Why? Reasons for measuring gait in real life conditions 2. What? Real-life assessment

More information

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system K. OBERG and H. LANSHAMMAR* Amputee Training and Research Unit, University Hospital, Fack,

More information

The NXT Generation. A complete learning solution

The NXT Generation. A complete learning solution The NXT Generation A complete learning solution 2008 The NXT Generation LEGO MINDSTORMS Education is the latest in educational robotics, enabling students to discover ICT, science, D&T and maths concepts

More information

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Acoustic Emission Testing of The Shell 0f Electromagnetic Valve guozhen XU 1, yiwei CHEN 1, zhihua CAO 2 ABSTRACT Shanghai

More information

SCHEINWORKS Measuring and Analysis Systems by

SCHEINWORKS Measuring and Analysis Systems by Pressure Measurement Systems for standing and walking analysis Germany since 1879 Pressure Measurement Systems for standing and walking analysis Documentation of Gait image Stance Symmetry of all parameters

More information

INSTRUMENT INSTRUMENTAL ERROR (of full scale) INSTRUMENTAL RESOLUTION. Tutorial simulation. Tutorial simulation

INSTRUMENT INSTRUMENTAL ERROR (of full scale) INSTRUMENTAL RESOLUTION. Tutorial simulation. Tutorial simulation Lab 1 Standing Waves on a String Learning Goals: To distinguish between traveling and standing waves To recognize how the wavelength of a standing wave is measured To recognize the necessary conditions

More information

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)

More information

Body Stabilization of PDW toward Humanoid Walking

Body Stabilization of PDW toward Humanoid Walking Body Stabilization of PDW toward Humanoid Walking Masaki Haruna, Masaki Ogino, Koh Hosoda, Minoru Asada Dept. of Adaptive Machine Systems, Osaka University, Suita, Osaka, 565-0871, Japan ABSTRACT Passive

More information

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2 Portable DGA Dissolved Gas Analyzer MITSUBISHI Portable Dissolved Gas Analyzer (PGA-300) is used to analyze 6 kinds of dissolved gases in transformer oil, thereby improving prompt action

More information

Bloodpressure measurement, improvement of oscillometric method.

Bloodpressure measurement, improvement of oscillometric method. Bloodpressure measurement, improvement of oscillometric method. Øystein Stene, Lars Jørgen Kristoffersen, Waldemar Sulkowski Høgskolen i Narvik, Sivilingeniørutdanningen, postboks 385, N-8501 Narvik Norway,

More information

Quadruple mass spectrometers (transducer type)

Quadruple mass spectrometers (transducer type) Quadruple mass spectrometers that meet the need for sensitive analysis and low outgassing which were specifically designed to be controlled by PCs Quadruple mass spectrometers (transducer type) M-070QA-TDF,

More information

APPLICATION OF THREE DIMENSIONAL ACCELEROMETRY TO HUMAN MOTION ANALYSIS

APPLICATION OF THREE DIMENSIONAL ACCELEROMETRY TO HUMAN MOTION ANALYSIS APPLICATION OF THREE DIMENSIONAL ACCELEROMETRY TO HUMAN MOTION ANALYSIS INTRODUCTION Ken'ichi Egawa, T. Tsuboi, T. Satoh, and M. Miyazaki Graduate School of Human Sciences, Waseda University Three dimensional

More information

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS WARNING THE WARRANTIES MADE BY MSA WITH RESPECT TO THE PRODUCT ARE VOIDED IF THE PRODUCT IS NOT USED AND MAINTAINED IN ACCORDANCE

More information

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric

More information

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams. Heat Engine Equipment: Capstone, 2 large glass beakers (one for ice water, the other for boiling water), temperature sensor, pressure sensor, rotary motion sensor, meter stick, calipers, set of weights,

More information

Artifacts Due to Filtering Mismatch in Drop Landing Moment Data

Artifacts Due to Filtering Mismatch in Drop Landing Moment Data Camenga et al. UW-L Journal of Undergraduate Research XVI (213) Artifacts Due to Filtering Mismatch in Drop Landing Moment Data Elizabeth T. Camenga, Casey J. Rutten, Brendan D. Gould, Jillian T. Asmus,

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

A CO 2 Waveform Simulator For Evaluation and Testing of Respiratory Gas Analyzers

A CO 2 Waveform Simulator For Evaluation and Testing of Respiratory Gas Analyzers 2011 ROCKY MOUNTAIN NASA SPACE GRANT CONSORTIUM 1 A CO 2 Waveform Simulator For Evaluation and Testing of Respiratory Gas Analyzers Christina Long, and Joseph Orr, Ph.D. Department of Bioengineering, University

More information

Controlling Walking Behavior of Passive Dynamic Walker utilizing Passive Joint Compliance

Controlling Walking Behavior of Passive Dynamic Walker utilizing Passive Joint Compliance Controlling Walking Behavior of Passive Dynamic Walker utilizing Passive Joint Compliance Takashi TAKUMA, Koh HOSODA Department of Adaptive Machine Systems, Graduate School of Engineering Osaka University

More information

Pulmonary Capacity Analyzer

Pulmonary Capacity Analyzer Pulmonary Capacity Analyzer micromedic Project Number micro13mm250 PREPARED BY: Marc A. Machin 21 Granada IrvIne, CA 92602 Phone - (714) 457-4539 Contents 1 1.1 1.2 PROJECT SUMMARY 1 Overview 1 Technical

More information

Blood Parameter Monitoring System 550

Blood Parameter Monitoring System 550 Technical Compendium CDI Blood Parameter Monitoring System 550 An overview of the CDI System 550 and its industry leading technology. CDI System 550 Measures or Calculates 12 Critical Blood Parameters

More information

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination Warning: Non-vented water level loggers may have readings with errors of up to 250mm due to barometric pressure changes.

More information

DST Host User Manual

DST Host User Manual For DST Host version 7.0 onwards, published October 2017 Cefas Technology Limited CONTENTS About this Manual... 2 Conventions used in this Manual... 2 Getting Started... 3 Installing the Host Software...

More information

Analysis of Foot Pressure Variation with Change in Stride Length

Analysis of Foot Pressure Variation with Change in Stride Length IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-853, p-issn: 2279-861.Volume 13, Issue 1 Ver. IV (Oct. 214), PP 46-51 Dr. Charudatta V. Shinde, M.S. MCh ( Orthopaedics ), Dr. Weijie

More information

SHIMADZU LC-10/20 PUMP

SHIMADZU LC-10/20 PUMP SHIMADZU LC-10/20 PUMP Clarity Control Module ENG Code/Rev.: M091/70C Date: 24.10.2017 Phone: +420 251 013 400 DataApex Ltd. Fax: +420 251 013 401 Petrzilkova 2583/13 clarity@dataapex.com 158 00 Prague

More information

S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE

S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE 1. INTRODUCTION The s-curve function allows the user to define a smooth response yet still maintain a high acceleration. In many applications

More information

Dynamic Component of Ship s Heeling Moment due to Sloshing vs. IMO IS-Code Recommendations

Dynamic Component of Ship s Heeling Moment due to Sloshing vs. IMO IS-Code Recommendations International Journal on Marine Navigation and Safety of Sea Transportation Volume 4 Number 3 September 2010 Dynamic Component of Ship s Heeling Moment due to Sloshing vs. IMO IS-Code Recommendations P.

More information

Ultrasonic motion analysis system - measurement of temporal and spatial gait parameters Huitema, RB; Hof, At L.; Postema, K

Ultrasonic motion analysis system - measurement of temporal and spatial gait parameters Huitema, RB; Hof, At L.; Postema, K University of Groningen Ultrasonic motion analysis system - measurement of temporal and spatial gait parameters Huitema, RB; Hof, At L.; Postema, K Published in: Journal of biomechanics IMPORTANT NOTE:

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President Lowell Instruments Application Note #TCMA Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President 1 Introduction The TCM-1 Tilt Current Meter (TCM)

More information

TR Electronic Pressure Regulator. User s Manual

TR Electronic Pressure Regulator. User s Manual TR Electronic Pressure Regulator Page 2 of 13 Table of Contents Warnings, Cautions & Notices... 3 Factory Default Setting... 4 Quick Start Procedure... 5 Configuration Tab... 8 Setup Tab... 9 Internal

More information

Queue analysis for the toll station of the Öresund fixed link. Pontus Matstoms *

Queue analysis for the toll station of the Öresund fixed link. Pontus Matstoms * Queue analysis for the toll station of the Öresund fixed link Pontus Matstoms * Abstract A new simulation model for queue and capacity analysis of a toll station is presented. The model and its software

More information

ACTIVITY MONITORING SYSTEM

ACTIVITY MONITORING SYSTEM ACTIVITY MONITORING SYSTEM Hardik Shah 1, Mohit Srivastava 2, Sankarshan Shukla 3, Dr. Mita Paunwala 4 Student, Electronics and Communication, CKPCET, Surat, Gujarat, India 1 Student, Electronics and Communication,

More information

Gait Analyser. Description of Walking Performance

Gait Analyser. Description of Walking Performance Gait Analyser Description of Walking Performance This brochure will help you to understand clearly the parameters described in the report of the Gait Analyser, provide you with tips to implement the walking

More information

Electronic Automatic Transmission for Bicycle

Electronic Automatic Transmission for Bicycle Electronic Automatic Transmission for Bicycle Team 4 Tianqi Liu, Ruijie Qi, and Xingkai Zhou ECE 445 Project Proposal Spring 2018 TA: Hershel Rege 1 Introduction 1.1 Objective Nowadays, an increasing number

More information

Exploring the Properties of Gases

Exploring the Properties of Gases Computer 30 The purpose of this investigation is to conduct a series of experiments, each of which illustrates a different gas law. You will be given a list of equipment and materials and some general

More information

EXPERIMENT 12 GAS LAWS ( BOYLE S AND GAY-LUSSAC S LAW)

EXPERIMENT 12 GAS LAWS ( BOYLE S AND GAY-LUSSAC S LAW) EXPERIMENT 12 GAS LAWS ( BOYLE S AND GAY-LUSSAC S LAW) INTRODUCTION: In order to specify fully the condition of a gas it is necessary to know its pressure, volume, and temperature. This quantities are

More information

siot-shoe: A Smart IoT-shoe for Gait Assistance (Miami University)

siot-shoe: A Smart IoT-shoe for Gait Assistance (Miami University) siot-shoe: A Smart IoT-shoe for Gait Assistance (Miami University) Abstract Mark Sullivan, Casey Knox, Juan Ding Gait analysis through the Internet of Things (IoT) is able to provide an overall assessment

More information

STAND alone & p.c. VERSION

STAND alone & p.c. VERSION STAND alone & p.c. VERSION ECONOMY TRACK SYSTEMS 1/4 & 1/8 Mile Asphalt Track Dirt / Sand Track Mud Track Snowmobile Track R/C Car Track Custom Track Systems Timing to.001 Accuracy Time Slip Printer Optional

More information

Motion Control of a Bipedal Walking Robot

Motion Control of a Bipedal Walking Robot Motion Control of a Bipedal Walking Robot Lai Wei Ying, Tang Howe Hing, Mohamed bin Hussein Faculty of Mechanical Engineering Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia. Wylai2@live.my

More information

The Scientific Bulletin of VALAHIA University MATERIALS and MECHANICS Nr. 5 (year 8) 2010

The Scientific Bulletin of VALAHIA University MATERIALS and MECHANICS Nr. 5 (year 8) 2010 STATISTIC PROCESSING OF MEASUREMENTS DONE WITH CALORCRO EQUIPMENT FOR ASSESSING THE GAIT ENERGETIC EXPENDITURE AT HEALTHY SUBJECTS AND PATIENTS SUFFERING FROM OSTEOARTHRITIS OF LOWER LIMBS G. CAPRIS 1),

More information

Complete Range of Force Tensiometers

Complete Range of Force Tensiometers Sigma Complete Range of Force Tensiometers Versatility, automation and accuracy Precision made simple Attension Force Tensiometers are used in research, development and quality control for the study of

More information

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi

More information

WALKING MOTION ANALYSIS USING SMALL ACCELERATION SENSORS

WALKING MOTION ANALYSIS USING SMALL ACCELERATION SENSORS WALKING MOTION ANALYSIS USING SMALL ACCELERATION SENSORS Teruaki Ito Institute of Technology and Science University of Tokushima Tokushima, Japan e-mail: ito@me.tokushima-u.ac.jp Abstract Human walking

More information

In addition to reading this assignment, also read Appendices A and B.

In addition to reading this assignment, also read Appendices A and B. 1 Kinematics I Introduction In addition to reading this assignment, also read Appendices A and B. We will be using a motion detector to track the positions of objects with time in several lab exercises

More information

APA software instruction manual

APA software instruction manual 1. Starting the program In order to start the control software for the APA device press APAxx shortcut located on the desktop of the supplied computer. XX corresponds to the current software version. When

More information

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

AN31E Application Note

AN31E Application Note Balancing Theory Aim of balancing How an unbalance evolves An unbalance exists when the principle mass axis of a rotating body, the so-called axis of inertia, does not coincide with the rotational axis.

More information

RESEARCH ON THE CHANGES OF THE RESCUERS HEART RATE DURING TRAINING

RESEARCH ON THE CHANGES OF THE RESCUERS HEART RATE DURING TRAINING RESEARCH ON THE CHANGES OF THE RESCUERS HEART RATE DURING TRAINING Daniel Pupazan, Phd. Eng.,INCD INSEMEX Petrosani Artur George Gaman, Phd. Eng.,INCD INSEMEX Petrosani Cosmin Ilie, Phd. Eng., INCD INSEMEX

More information

Essential ski characteristics for cross-country skis performance

Essential ski characteristics for cross-country skis performance Proceedings of 7 th ISEA CONFERENCE 2008 Biarritz, June 2-6, 2008 for cross-country skis performance Mikael Bäckström 1, Leon Dahlen 2, Mats Tinnsten 3 (1), (2), (3): Department of Engineering, Physics

More information

Basic - Peripheral Vascular Assessment VASCULAR DOPPLER PHOTO-PLETHYSMOGRAPHY PULSE VOLUME RECORDING ANKLE AND TOE BRACHIAL INDEX

Basic - Peripheral Vascular Assessment VASCULAR DOPPLER PHOTO-PLETHYSMOGRAPHY PULSE VOLUME RECORDING ANKLE AND TOE BRACHIAL INDEX VASCULAR DOPPLER PHOTO-PLETHYSMOGRAPHY PULSE VOLUME RECORDING ANKLE AND TOE BRACHIAL INDEX Vscular Specialist Angiologist Phlebologist Cardiologist Diabetologist The newest technology in a space-saving

More information

REAL. Simple, Intuitive, Powerful Real.

REAL. Simple, Intuitive, Powerful Real. REAL Simple, Intuitive, Powerful Real. When we set out to define the bikefitting.com toolset engineered by Shimano Dynamics Lab, these were a few of the stand out priorities we wanted to achieve. We delivered.

More information

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument OxyScan Graphic Operating Instructions UMS Micro-oxygen sensor 501 Microprocessor instrument Introduction Thank you for choosing the UMS Micro Oxygen Sensor 501 - a highly advanced product! Please read

More information

Vibration Analysis and Test of Backup Roll in Temper Mill

Vibration Analysis and Test of Backup Roll in Temper Mill Sensors & Transducers 2013 by IFSA http://www.sensorsportal.com Vibration Analysis and Test of Backup Roll in Temper Mill Yuanmin Xie College of Machinery and Automation, Wuhan University of Science and

More information

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN Data Sheet: DFP.418.R4.EN www.ntt.dk Digital Pressure Gauge PRESSURE FORCE The DFP series digital gauges are made according to the more modern technologies in order to provide a high level of reliability,

More information

Precision digital pressure gauge Model CPG1000

Precision digital pressure gauge Model CPG1000 Calibration technology Precision digital pressure gauge Model CPG1000 WIKA data sheet CT 10.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service

More information

SonoSelect 10 and SonoSafe 10 energy meters

SonoSelect 10 and SonoSafe 10 energy meters SonoSelect 10 and SonoSafe 10 energy meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

Electronic Volume Correctors

Electronic Volume Correctors Electronic Volume Correctors Ben Manson Landis+Gyr October 14, 2016 PUBLIC Agenda Customer Types and suitable equipment Volume corrector standards / regulations Basics of volume correction Gauge v Absolute

More information

Timers, Interrupts, and Square Wave Generation. Ryan Krauss. Southern Illinois University Edwardsville. October 24, 2007

Timers, Interrupts, and Square Wave Generation. Ryan Krauss. Southern Illinois University Edwardsville. October 24, 2007 Timers, Interrupts, and Square Wave Generation Ryan Krauss Southern Illinois University Edwardsville October 24, 2007 Timers and Interrupts - Why should we care? Gives us the ability to precisely schedule

More information

Wade Reynolds 1 Frank Young 1,2 Peter Gibbings 1,2. University of Southern Queensland Toowoomba 4350 AUSTRALIA

Wade Reynolds 1 Frank Young 1,2 Peter Gibbings 1,2. University of Southern Queensland Toowoomba 4350 AUSTRALIA A Comparison of Methods for Mapping Golf Greens Wade Reynolds 1 Frank Young 1,2 Peter Gibbings 1,2 1 Faculty of Engineering and Surveying 2 Australian Centre for Sustainable Catchments University of Southern

More information

Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS)

Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS) Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS) A. Scope of Work The work covered by these specifications consists of furnishing all materials, labor,

More information

Vertical in situ profiles of nitrate and oxygen in the northern Japan Sea

Vertical in situ profiles of nitrate and oxygen in the northern Japan Sea Vertical in situ profiles of nitrate and oxygen in the northern Japan Sea Dmitry D. Kaplunenko, Vyacheslav B. Lobanov, Pavel Ya. Tishchenko and Maria G. Shvetsova V.I.Il'ichev Pacific Oceanological Institute,

More information

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11 ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11 The Portatree Eliminator Super 2000 Competition Track Timer can be used with an IBM Compatible Personal Computer connected through Com Port

More information

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer. NXT Main Menu My Files Files are automatically placed into the appropriate folders. When you download a program using a Sound file to the NXT, the program will be placed under Software files while the

More information

PUV Wave Directional Spectra How PUV Wave Analysis Works

PUV Wave Directional Spectra How PUV Wave Analysis Works PUV Wave Directional Spectra How PUV Wave Analysis Works Introduction The PUV method works by comparing velocity and pressure time series. Figure 1 shows that pressure and velocity (in the direction of

More information

TEMPORAL ANALYSIS OF THE JAVELIN THROW

TEMPORAL ANALYSIS OF THE JAVELIN THROW TEMPORAL ANALYSIS OF THE JAVELIN THROW Derek M. Helenbergerl, Michael T. Sanders 2, and Lawrence D. Abraha~n',~ Biomedical Engineering, Intercollegiate Athletics for Men, Kinesiology & Health Education

More information

1. Functional description. Application program usage. 1.1 General. 1.2 Behavior on bus voltage loss and bus voltage. 1.

1. Functional description. Application program usage. 1.1 General. 1.2 Behavior on bus voltage loss and bus voltage. 1. Application program usage product family: Product type: Manufacturer: Name: Order-No.: Valve actuators Constant valve actuator Siemens Valve actuator AP 562/02 5WG1 562-7AB02 Commissioning For commissioning

More information

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Application Positioner firmware for early detection of control valve faults giving maintenance recommendations. Valid

More information

AMS 6915 Board mount pressure sensor with digital output (I²C)

AMS 6915 Board mount pressure sensor with digital output (I²C) Board mount pressure sensor with digital output (I²C) FEATURES Calibrated and temperature compensated pressure sensor with digital output (I²C) Differential, relative (gage), bidirectional differential,

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

MIE Medical Research Ltd Digital Analyser Pinch/Grip Instruction Manual

MIE Medical Research Ltd Digital Analyser Pinch/Grip Instruction Manual Doc 116-03 Copyright 1998-2004 MIE Medical Research Ltd Getting Started MIE Medical Research Ltd Unpack your Digital Analyser and check that the following components are present: 1 x Digital Analyser

More information

Specifications for the CMI 2409 Magnetocardiograph

Specifications for the CMI 2409 Magnetocardiograph Specifications for the CMI 2409 Magnetocardiograph Revision date April 14, 2006 1 518-381-1000 (tel) The CMI-2409 system consists of a holder (A), a patient bed (B) and a workstation (not shown in the

More information

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet Data sheet MEGAS 2.0 Gas analysis with direct C-Level Calculation and Bus-Connection Mesa Industrie-Elektronik GmbH Neckarstraße 19, D-45768 Marl info@mesa-gmbh.de +49 (0) 2365-97 45 1-0 +49 (0) 2365-97

More information

Science&Motion. SAM BalanceLab. Sports. control the invisible. Most advanced pressure plate for coaching

Science&Motion. SAM BalanceLab. Sports. control the invisible. Most advanced pressure plate for coaching SAM BalanceLab Science&Motion Sports control the invisible Most advanced pressure plate for coaching Balance - the invisible key to success Stop the guesswork and start to rely on facts Science and Motion

More information

WHITEPAPER. Integrated process monitoring of dosing pressures

WHITEPAPER. Integrated process monitoring of dosing pressures Integrated process monitoring of dosing pressures Detect and avoid errors during dosing with the flowplus 16 dosing pressure monitoring system and flowscreen Fig. 1: flowplus 16 relative pressure sensor

More information

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high) Exploring the Properties of Gases Computer 30 The purpose of this investigation is to conduct a series of experiments, each of which illustrates a different gas law. You will be given a list of equipment

More information

LASER INDUCED FLUORESCENCE MEASUREMENTS OF CARBON DIOXIDE DISSOLUTION IN WAVE-BREAKING TURBULENCE

LASER INDUCED FLUORESCENCE MEASUREMENTS OF CARBON DIOXIDE DISSOLUTION IN WAVE-BREAKING TURBULENCE LASER INDUCED FLUORESCENCE MEASUREMENTS OF CARBON DIOXIDE DISSOLUTION IN WAVE-BREAKING TURBULENCE Yasunori Watanabe 1, Junichi Otsuka 2 and Ayumi Saruwatari 3 Spatial distributions of dissolved carbon

More information

Mass Flowmeters. Mass Flowmeters for Gases

Mass Flowmeters. Mass Flowmeters for Gases Mass Flowmeters Mass Flowmeters for Gases Fast, Accurate, Low Pressure Drop for critical measurement applications! Flow (Std l/min) Response to a step change in flowrate 300 200 100 4 Milliseconds 63%

More information

IMPC phenotyping SOPs in JMC

IMPC phenotyping SOPs in JMC IMPC phenotyping SOPs in JMC Indirect Calorimetry IMPC_CAL_002 Purpose Indirect calorimetry provides detailed information on the energy metabolism of mutant mice. Energy expenditure is evaluated through

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no

More information

Root Cause Determination of Excessive Hull Vibration On a First-In-Class Tugboat Design By Wylie Moreshead, P.E., Azima DLI

Root Cause Determination of Excessive Hull Vibration On a First-In-Class Tugboat Design By Wylie Moreshead, P.E., Azima DLI Root Cause Determination of Excessive Hull Vibration On a First-In-Class Tugboat Design By Wylie Moreshead, P.E., Azima DLI In August of 2002, Azima DLI was tasked to collect vibration data on a new tug

More information

Linear Infl ation Technology Non-invasive Blood Pressure Measurement. inibp Case Report Experiences in OR

Linear Infl ation Technology Non-invasive Blood Pressure Measurement. inibp Case Report Experiences in OR Linear Infl ation Technology Non-invasive Blood Pressure inibp Case Report Experiences in OR C ONTENTS Introduction 2 Technological Description of inibp inibp advantages 2 inibp technology adapts to each

More information

Analysis of Gait Characteristics Changes in Normal Walking and Fast Walking Of the Elderly People

Analysis of Gait Characteristics Changes in Normal Walking and Fast Walking Of the Elderly People IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 08, Issue 7 (July. 2018), V (V) 34-41 www.iosrjen.org Analysis of Gait Characteristics Changes in and Of the Elderly

More information

rmatics (IWIN 213) proposed by the American College of Sports Medicine and is expressed in the following expression (1). EE = 1.5 MET s W T (1) EE mea

rmatics (IWIN 213) proposed by the American College of Sports Medicine and is expressed in the following expression (1). EE = 1.5 MET s W T (1) EE mea An Estimation Method of Calorie Consumption in Activities of Daily Living based on METs Values Yoshitaka Nakamura, Yoshiki Matsubayashi, Yoh Shiraishi, and Osamu Takahashi School of Systems Information

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information