Validation of a patient activity monitor to quantify ambulatory activity in an amputee population

Size: px
Start display at page:

Download "Validation of a patient activity monitor to quantify ambulatory activity in an amputee population"

Transcription

1 Prosthetics and Orthotics International June 2007; 31(2): Validation of a patient activity monitor to quantify ambulatory activity in an amputee population N. RAMSTRAND & K.-Å. NILSSON Department of Rehabilitation, School of Health Sciences, Jönköping University, Sweden Abstract The ability to objectively measure an amputee s walking activity over prolonged periods can provide clinicians with a useful means of evaluating their patients outcomes. The present study aimed to validate the temporospatial data output from a commercially available ambulatory activity monitor (PAM, Össur) fitted to trans-tibial and trans-femoral amputees, against data that was simultaneously captured from a three dimensional motion analysis system (Qualisys Medical AB, Gothenburg, Sweden). Results indicate that the PAM monitor provides accurate measures of temporospatial aspects of amputee gait for walking speeds above 0.75 m/s. Keywords: Activity monitor, amputee gait, validity Introduction Physical activity has been demonstrated as beneficial in lowering the risk of chronic diseases and as having significant positive health benefits (Argiropoulou et al. 2004; Schneider et al. 2003). It is identified as a primary determinant of quality of life and is subsequently considered to be one of the major goals of rehabilitation (Culhane et al. 1995). The feasibility of accurately determining levels of patients walking activity has improved substantially with the introduction of sophisticated long-term ambulatory activity monitors (Table I). Such monitors are capable of continuously logging various temporospatial gait parameters for periods of days to months. The most commonly utilized motion detection mechanism within commercially available walking activity monitors are two or three-dimensional accelerometers. There have been a number of studies that have assessed the validity of different ambulatory activity monitors by comparing their data output against alternate measures. Studies have included comparisons of activity monitor generated data to pedometers (Macko et al. 2002; Shepherd et al. 1999), comparisons with the number of steps counted by an observer (Resnick et al. 2001; Hartsell et al. 2002) and the recorded speed of treadmill walking (Schultz et al. 2002). Results to date indicate that activity monitors generate less overall error when compared to pedometers (Shepherd et al. 1999; Macko et al. 2002), correlate highly with Correspondence: N. Ramstrand, School of Health Sciences, Jönköping University, Box 1026, SE Jönköping, Sweden. nerrolyn.ramstrand@hhj.hj.se ISSN print/issn online Ó 2007 ISPO DOI: /

2 158 N. Ramstrand & K.-Å. Nilsson Table I. Commercially available, long-term, activity monitors. Manufacturer Activity monitor Motion detection mechanism Maximum recording time Parameters measured ActiGraph, LLC (Fort Walton Beach, USA) Cyma (Mountlake Terrace, USA) FitSense (Southborough, USA) Össur (Reykjavik, Iceland) Stayhealthy, INC (Monrovia, USA) GTIM ActiGraph Accelerometer 1 year (when collecting just one activity) StepWatch Custom sensor Two months (when recording at 1 minute intervals) The Pacer TM Accelerometer 30 days. Step count. Distance travelled. Velocity. Caloric burn. Step count. Distance traveled. Individual activity level. Energy and Caloric Expenditure. Duration of sustained activity. Daily activity profile. Skin temperature. Sleep patterns and Ambient light levels. Total number of steps taken. Steps per unit time - time intervals specified by the user. Time and steps spent at low moderate and high activity Ossur PAM TM Accelerometer 7 days. Time spent not active, active, and in locomotion. Total number of steps taken. Average step length. Distance travelled. Maximum speed in locomotion. Average speed in locomotion. Impact RT3 Tri-axial Research Tracker Accelerometer 21 days (when recording at 1 minute intervals). Activity units. Activity kilocalories. Metabolic equivalent units (MET s)

3 Activity monitor validity 159 steps that were simultaneously counted by an observer (Coleman et al. 1999; Resnick et al. 2001; Hartsell et al. 2002) and correlate highly with measures of walking speed that are simultaneously recorded on a treadmill (Schultz et al. 2002). The accuracy of the StepWatch device (Cyma, Mountlake Terrace, WA) has been reported in numerous publications and has been successfully used to measure different styles of gait (Resnick et al. 2001; Silva et al. 2002; Macko et al. 2002). Given that so little is currently known of the walking activities and gait characteristics of amputee subjects outside of the artificial laboratory environment, activity monitors have great potential for use in this population. A valid and reliable walking activity monitor can provide valuable information to those involved in amputee care through the provision of objective information regarding patient activity levels after different surgical, prosthetic or therapeutic interventions. Monitors can also provide useful information regarding the maintenance of temporospatial gait characteristics outside the constraints of the laboratory environment. Little evidence currently exists to demonstrate that gait characteristics of amputees are maintained when patients enter an unconstrained free-living environment and are no longer under the watchful and judgemental eyes of clinicians. The Patient Activity Monitor (PAM) (Össur, Reykjavik, Iceland) is a recent addition to commercially available walking activity monitors and is specifically targeted towards evaluation of amputee gait patterns. The monitor is a small unit (85 mm638 mm632 mm) that is attached to the anterior surface of the leg, 20 cm from the ground. The unit weights 50 grams and is capable of capturing continuous data for a one week period. Stride characteristics are determined from an algorithm that processes data from one biaxial accelerometer and one uniaxial accelerometer (Bussmann et al. 2004). Select outputs from PAM have previously been described as valid for the evaluation of activity in a transtibial amputee population. Results have demonstrated a strong agreement between PAM data and manual measures of step count and walking speed measured on a treadmill (Bussmann et al. 2004). To date the accuracy of step length measurements recorded by the PAM have not been investigated. Neither has the ability of the PAM to accurately detect temporospatial gait parameters in a trans-femoral amputee population. Given that the typical gait pattern of a trans-femoral amputee is characterised by reduced angular motion of the tibial segment, precisely where the PAM device is positioned, it is important to establish if the algorithm employed by PAM to detect when a step is taken is equally valid for both trans-tibial and trans-femoral amputees. The aim of the present study was therefore to compare recordings of select gait parameters in both trans-tibial and trans-femoral amputees using the Össur Patient Activity Monitor and to evaluate the output against data captured using three-dimensional motion analysis. Method Subjects Ten trans-tibial and twelve trans-femoral amputees were recruited for the study from the Jönköping University volunteer patient register. Amputees were selected on the basis that they were currently using a prosthesis for daily activities and were capable of walking unaided for a five minute period without a pause. All subjects were required to provide informed written consent before participating in the study and were informed that they may withdraw their participation at any time. All protocols were approved by the regional ethics board in Linköping, Sweden, prior to commencement of the study.

4 160 N. Ramstrand & K.-Å. Nilsson Testing protocol Before testing, the Patient Activity Monitor (PAM) was fitted to the subjects prosthetic side according to the manufacturer s instructions. In addition, a single retro-reflective marker was placed on the toe-box of the patients left and right shoes. These markers were subsequently tracked in three-dimensional space using a six camera computerised motion analysis system (Qualisys Medical AB, Gothenburg, Sweden). Computerised motion analysis systems have been reported as having the ability to measure temporal and spatial gait parameters with high levels of validity and reliability (Barker et al. 2005). Subjects were requested to walk on a treadmill for three five-minute periods at selfselected slow, medium and fast walking velocities. Participants were permitted to rest for as long as necessary between trials. Walking velocities were determined by the subject prior to testing. Testing for each walking velocity was randomised across patients. For each walking trial, data was simultaneously collected from the PAM and from the Qualysis three-dimensional motion analysis system. In addition to the computerised motion analysis system, an investigator used a hand tally counter to record the total number of steps taken. After each of the walking trials, data from the PAM was recorded and the unit was cleared for the next walking trial. Motion analysis files were saved in a file folder for subsequent analysis. Data analysis Three-dimensional motion analysis files were analysed using Visual 3D motion analysis software (C-motion, Inc.). Specific values were generated for the total number of steps, average walking velocity and average step length. Pearson s correlation coefficients were calculated to compare the strength of the relationship between data collected from the three-dimensional motion analysis system against the PAM outputs for the same variables. Data was analysed using SPSS software (SPSS for Windows, Rel Chicago: SPSS Inc.). To visualise the relationship between variables, Bland-Altman plots were used. With the Bland-Altman plot, the relationship between the measurement error and the true value can be evaluated (Bland and Altman 1986). The method also serves to evaluate if the measures are normally distributed by using a 95% confidence interval. Results General The authors tested 22 participants who had a mean age of 50 years (Median ¼ 51). The sample included 12 subjects with trans-femoral amputation and 10 with trans-tibial amputation. The mean latency since amputation was 22 years (Median ¼ 20; SD ¼ 16). Each patient was measured walking at their self-selected slow, medium and fast walking velocities. On nine occasions the PAM failed to register data. This occurred at the self-selected slow walking velocity in 5 of the cases. Each of the trials in which PAM failed to register data was removed from the data analysis. One further trial (subject 2 at self-selected fast walking velocity) was also removed from analysis due to a marker tracking failure related to the motion analysis system. After removal of unsuccessful trials a total of 56 trials were available for analysis.

5 Activity monitor validity 161 Step count A scatter plot depicting the total step count as calculated by the PAM and the Qualisys motion analysis systems for trans-tibial and trans-femoral amputees is presented in Figure 1A. The correlation between values obtained using the PAM and those obtained from the hand count and the Qualisys motion analysis system were investigated using Pearson s correlation coefficient. Results are summarized in Table II and show very high correlation between step count, as recorded by PAM, and that which was recorded by the Qualysis motion analysis system and the hand counter. Results indicated no difference in the correlation coefficients when comparing trans-tibial (r ¼ 0.97) and trans-femoral amputees (r ¼ 0.98). Figure 1B depicts the agreement of the PAM and Qualisys methods by using a Bland-Altman plot. The difference between the two measurements was plotted versus the averages of the two measurements. The closer the points are to the horizontal axis the better the agreement. Inspection of the plot indicates that the PAM is measuring high most of the time and that the spread of the data is increased at lower average step counts. The average difference between the two methods was with a standard deviation of The Bland-Altman limits of agreement were to 21.3 steps suggesting that over a five minute walking period one could expect the PAM to record between 43 steps less to 21 steps more than the Qualisys system. Walking velocity The correlation between average walking velocity as recorded by PAM and that which was recorded by the Qualysis motion analysis system was calculated for slow (r ¼ 0.95), medium (r ¼ 0.99) and fast (r ¼ 0.98) walking velocities (Figure 2A). Results indicate a very strong correlation between both methods of determining walking velocity. Again, no difference in correlation coefficient was noted when comparing overall correlation coefficients between trans-femoral and trans-tibial amputees. Correlation coefficients for trans-femoral and transtibial amputees were 0.98 and 0.99, respectively. Bland-Altman plots for walking velocity are presented in Figure 2B. The average difference between the two methods was with a standard deviation of The Bland-Altman limits of agreement were to Step length A scatter plot of step length data is depicted in Figure 3A. Correlation coefficients were very high between the two data collection methods for fast (r ¼ 0.95) and medium (r ¼ 0.95) walking velocities. At the self-selected slow walking velocity, correlation was moderate (r ¼ 0.77). Amputation level appeared to have a slight influence on the ability of the PAM to accurately record measures of step length. Trans-femoral amputees recorded correlation coefficients of 0.93, 0.95 and 0.36 for fast, medium and slow walking velocities respectively while trans-tibial amputees recorded correlation coefficients of 0.98, 0.99 and Bland- Altman plots (Figure 3B) indicate that PAM recorded lower values than the Qualisys system when step length was shorter and higher values when step length was longer. The mean average difference was 0.03 (SD 0.05). Bland-Altman limits of agreement were to Discussion The present study indicates that the PAM is an acceptable method for measuring walking activity in both trans-tibial and trans-femoral amputees ambulating on a level treadmill. Very high average correlations were achieved when comparing data related to step count, walking

6 162 N. Ramstrand & K.-Å. Nilsson Figure 1. (A) Scatter plot of the number of steps as calculated by PAM versus the number of steps as calculated using the Qualisys motion analysis system; (B) Bland-Altman plot depicting the error scores (PAM-Qualisys). The solid line represents the mean difference and the dashed line represents the 95% confidence interval.

7 Activity monitor validity 163 Table II. Correlation coefficients presenting combined results from trans-tibial and trans-femoral amputees for the number of steps taken over a 5-minute walking trial. Speed PAM versus 3D motion analysis system PAM versus hand counter Fast Medium Slow velocity and step length between the PAM and a three-dimensional motion analysis system. Some evidence is presented to suggest that the PAM becomes less reliable at slower walking velocities, particularly in the case of trans-femoral amputees. This can be illustrated by analysing the cases in which PAM failed to register any data. Of the nine occasions that PAM failed to register data, five occurred at the self-selected slow walking velocity of five subjects (subjects 2, 4, 5, 6 and 14) while the remaining four cases are accounted for by the fact that no PAM data was registered from any of the walking trials (slow, medium and fast) for two subjects (subjects 4 and 14). Of the five subjects in whom problems were experienced collecting data from PAM, four were trans-femoral amputees while only one was a trans-tibial amputee. Further evidence that PAM is less reliable at slow walking velocities can be suggested from the correlation coefficients calculated for each of the variables measured. In all cases, the correlation coefficients calculated for self-selected slow walking velocity were lower than those calculated for medium and fast walking. This was particularly the case for measures of step length in trans-femoral amputees. Results from the present study have significant implications for the use of PAM during the early phases of rehabilitation. During this time an amputee s gait is typically characterized by a reduced step length, reduced walking velocity and a reduced total number of steps taken over a defined period of time. It is clear from the Bland-Altman plots presented in this paper that PAM has a tendency to record an underestimation of each of these variables when they are at their lower range and to overestimate them when they are at the upper range. It must be recognized that the average self-selected slow walking velocity (0.59 m/s) in this study was lower than the manufactures recommended minimum of 0.75 m/s. Nevertheless caution should be exercized when considering using the device on amputees who walk at slower velocities. Patients self-selected walking speeds were lower in the present study than those recorded for trans-tibial amputees walking on level ground by Bussmann et al. (2004). This may be attributed to the fact the self-selected speeds in the present study were determined as subjects walked on a treadmill. It has been demonstrated that accommodation to treadmill walking can be particularly difficult and may not appropriately simulate overground walking (Wass et al. 2004). Results are however consistent between both studies in suggesting that PAM was highly accurate in detecting measures of stride count and walking speed. The findings of this study are encouraging but it is important to consider limitations of the study design. Firstly the investigation was performed on a treadmill with subjects walking on a level surface. It is subsequently not possible to generalize results to naturalistic conditions that amputees would normally be subject to. This includes walking on uneven terrain, slopes and stairs. Clearly the ability of the device to accurately record activity over varying terrain conditions is necessary. These issues have been addressed in part by Bussmann et al. (2004). A number of variables reported by PAM were not investigated in this study. These include values for the PAM index, idle time, active time, locomotion time, impact (mean peak axial acceleration) and top speed. Further investigation is necessary to determine the validity of

8 164 N. Ramstrand & K.-Å. Nilsson Figure 2. (A) Scatter plot of walking velocity as calculated by PAM versus velocity calculated using the Qualisys motion analysis system; (B) Bland-Altman plot depicting the error scores (PAM-Qualisys). The solid line represents the mean difference and the dashed line represents the 95% confidence interval.

9 Activity monitor validity 165 Figure 3. (A) Scatter plot of step length as calculated by PAM versus step length calculated using the Qualisys motion analysis system; (B) Bland-Altman plot depicting the error scores (PAM-Qualisys). The solid line represents the mean difference and the dashed line represents the 95% confidence interval.

10 166 N. Ramstrand & K.-Å. Nilsson these measures if they are to be routinely adopted as outcome measures in the management of amputees. Finally, it should be recognized that the calculation of step length data from PAM is calculated by dividing stride length by a factor of two. This assumes that the patient is walking symmetrically. One must recognise that, particularly in the case of amputee subjects, this is unlikely to be the case (Nolan 2003). Conclusion The PAM has been demonstrated as a promising tool for measuring specific gait parameters in both trans-tibial and trans-femoral amputees. Caution should be exercized when considering using the device on subjects who walk at slower velocities. References Argiropoulou EC, Michalopoulou M, Aggeloussis N, Avgerinos A Validity and reliability of physical activity measures in Greek high school age children. J Sports Sci Med 3: Barker S, Craik R, Freedman W, Herrmann N, Hillstrom H Accuracy, reliability and validity of a spatiotemporal gait analysis system. Med Eng Phys. In Press. Bland JM, Altman DG Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:8476: Bussmann J, Martens W, Tulen J, Schasfoort F, van den Berg-Emons H, Stam H Measuring daily behavior using ambulatory accelerometry: the activity monitor. Behav Res Methods Instrum Comput 33: Coleman K, Smith D, Boone D, Joseph A, del Aguila M Step activity monitor: long-term, continuous recording of ambulatory function. J Rehabil Res Dev 36:1 12. Culhane KM, O Connor MO, Lyons D, Lyons GM Accelerometers in rehabilitation medicine for older adults. Age Ageing 34: Hartsell H, Fitzpatrick D, Brand R, Frantz R, Saltzman C Accuracy of a custom-designed activity monitor: implications for diabetic foot ulcer healing. J Rehabil Res Dev 39: Macko R, Haeuber E, Shaughnessy M, Coleman K, Boone D, Smith G, Silver K Microprocessor-based ambulatory activity monitoring in stroke patients. Med Sci Sports Exerc 34: Nolan L, Wit A, Dudzinski K, Lees A, Lake M, Wychowanski M Adjustments in gait symmetry with walking speed in trans-femoral and trans-tibial amputees. Gait Posture 17: Ravi N, Dandekar N, Mysore P, Littman M Activity recognition from accelerometer data. Proceedings of the seventeenth innovative applications of artificial intelligence conference, Menlo Park, California. AAAI Press. Resnick B, Nahm E, Orwig D, Zimmerman S, Magaziner J Measurement of activity in older adults: reliability and validity of the Step Activity Monitor. J Nurs Meas 9: Schneider PL, Crouter SE, Lukajic O, Bassett DJ Accuracy and reliability of 10 pedometers for measuring steps over a 400-m walk. Med Sci Sports Exerc 35: Schutz Y, Weinsier S, Terrier P, Durrer D A new accelerometric method to assess the daily walking pracice. Int J Obes Relat Metab Disord 26: Shepherd E, Toloza E, McClung C, Schmalzried T Step activity monitor: increased accuracy in quantifying ambulatory activity. J Orthop Res 15: Silva M, Shepherd EF, Jackson WO, Dorey FJ, Schmalzried TP Average patient walking activity approaches 2 million cycles per year: pedometers under-record walking activity. J Arthroplasty 17: Wass E, Taylor NF, Matsas A Familiarisation to treadmill walking in unimpaired older people. Gait Posture 21: Whittle M Gait analysis an introduction. Oxford: Butterworth-Heinemann: Oxford.

Test-Retest Reliability of the StepWatch Activity Monitor Outputs in Individuals

Test-Retest Reliability of the StepWatch Activity Monitor Outputs in Individuals Test-Retest Reliability of the StepWatch Activity Monitor Outputs in Individuals with Chronic Stroke Suzie Mudge, MHSc; N. Susan Stott, PhD Department of Surgery, University of Auckland Address for correspondence:

More information

Validity of the StepWatch. Criterion validity of the StepWatch Activity Monitor as a measure of walking. activity in individuals following stroke.

Validity of the StepWatch. Criterion validity of the StepWatch Activity Monitor as a measure of walking. activity in individuals following stroke. 1 Validity of the StepWatch 2 3 4 Criterion validity of the StepWatch Activity Monitor as a measure of walking activity in individuals following stroke. 5 1 6 7 Criterion validity of the StepWatch Activity

More information

STROKE IS THE MOST COMMON cause of severe disability

STROKE IS THE MOST COMMON cause of severe disability 1710 ORIGINAL ARTICLE Criterion Validity of the StepWatch Activity Monitor as a Measure of Walking Activity in Patients After Stroke Suzie Mudge, MHSc, N. Susan Stott, PhD, Sharon E. Walt, PhD ABSTRACT.

More information

Gait Analyser. Description of Walking Performance

Gait Analyser. Description of Walking Performance Gait Analyser Description of Walking Performance This brochure will help you to understand clearly the parameters described in the report of the Gait Analyser, provide you with tips to implement the walking

More information

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system K. OBERG and H. LANSHAMMAR* Amputee Training and Research Unit, University Hospital, Fack,

More information

Walking speemtmmkubjects and amputees: aspects of validity of gait analysis

Walking speemtmmkubjects and amputees: aspects of validity of gait analysis Prostheticsand Orthoti~Inte~national, 1993, 17, 78-82 Walking speemtmmkubjects and : aspects of validity of gait analysis A. M. BOONSTRA*, V. FIDLER** and W. H. EISMA* *Department of Rehabilitation Medicine,

More information

Ambulatory monitoring of gait quality with wearable inertial sensors

Ambulatory monitoring of gait quality with wearable inertial sensors Ambulatory monitoring of gait quality with wearable inertial sensors Dr. Philippe Terrier, PhD June 2016 Summary 1. Why? Reasons for measuring gait in real life conditions 2. What? Real-life assessment

More information

Analysis of Foot Pressure Variation with Change in Stride Length

Analysis of Foot Pressure Variation with Change in Stride Length IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-853, p-issn: 2279-861.Volume 13, Issue 1 Ver. IV (Oct. 214), PP 46-51 Dr. Charudatta V. Shinde, M.S. MCh ( Orthopaedics ), Dr. Weijie

More information

Validity of the iphone 5S M7 motion co-processor. as a pedometer for able-bodied persons. Micah Alford 9/7/2014

Validity of the iphone 5S M7 motion co-processor. as a pedometer for able-bodied persons. Micah Alford 9/7/2014 Validity of the iphone 5S M7 motion co-processor as a pedometer for able-bodied persons Micah Alford 9/7/2014 Abstract Objectives: The specific aim of this study is to assess the concurrent validity of

More information

Effects of Age and Body Mass Index on Accuracy of Simple Moderate Vigorous Physical Activity Monitor Under Controlled Condition

Effects of Age and Body Mass Index on Accuracy of Simple Moderate Vigorous Physical Activity Monitor Under Controlled Condition Received: May., 011 Accepted: Jul. 8, 011 Published online: Jul. 5, 011 Original Article Effects of Age and Body Mass Index on Accuracy of Simple Moderate Vigorous Physical Activity Monitor Under Controlled

More information

THE INFLUENCE OF SLOW RECOVERY INSOLE ON PLANTAR PRESSURE AND CONTACT AREA DURING WALKING

THE INFLUENCE OF SLOW RECOVERY INSOLE ON PLANTAR PRESSURE AND CONTACT AREA DURING WALKING March 12, 2015 5:39:44pm WSPC/170-JMMB 1540005 ISSN: 0219-51942nd Reading Journal of Mechanics in Medicine and Biology Vol. 15, No. 2 (2015) 1540005 (6 pages) c World Scientific Publishing Company DOI:

More information

HHS Public Access Author manuscript Int J Cardiol. Author manuscript; available in PMC 2016 April 15.

HHS Public Access Author manuscript Int J Cardiol. Author manuscript; available in PMC 2016 April 15. FITBIT : AN ACCURATE AND RELIABLE DEVICE FOR WIRELESS PHYSICAL ACTIVITY TRACKING Keith M. Diaz 1, David J. Krupka 1, Melinda J Chang 1, James Peacock 1, Yao Ma 2, Jeff Goldsmith 2, Joseph E. Schwartz 1,

More information

Treadmill and daily life

Treadmill and daily life 4 Treadmill and daily life Fall-related gait characteristics on the treadmill and in daily life, SM Rispens, JH van Dieën, KS van Schooten, LE Cofre Lizama, A Daffertshofer, PJ Beek, M Pijnappels, Journal

More information

Accuracy of a Pedometer and an Accelerometer in Women with Obesity

Accuracy of a Pedometer and an Accelerometer in Women with Obesity The Open Obesity Journal, 2012, 4, 11-17 11 Open Access Accuracy of a Pedometer and an Accelerometer in Women with Obesity Malin Wiklund *, Åsa Cider and Monika Fagevik Olsén Department of Physiotherapy

More information

Circuit breaker diagnostic testing. Megger is a registered trademark

Circuit breaker diagnostic testing. Megger is a registered trademark WWW.MEGGER.COM Megger is a registered trademark Title Author Nils Wäcklén Date January 2010 Keywords TM1600, TM1800, CIGRÉ, vibration analysis, dynamic resistance measurement, circuit breaker testing,

More information

ETB Pegasus equipment was used in the following paper

ETB Pegasus equipment was used in the following paper INNOVATIVE MOTION PRODUCTS ETB Pegasus equipment was used in the following paper Validation of a Novel Accelerometer-GPS system for measuring stride characteristics in galloping horses JRJ Naylor and DJ

More information

Goodyear Safety Research Project 2008 Presentation by Competitive Measure at the FEI Eventing Safety Forum. Presented by Tim Deans and Martin Herbert

Goodyear Safety Research Project 2008 Presentation by Competitive Measure at the FEI Eventing Safety Forum. Presented by Tim Deans and Martin Herbert Goodyear Safety Research Project 2008 Presentation by Competitive Measure at the FEI Eventing Safety Forum Presented by Tim Deans and Martin Herbert The presentation discusses the Goodyear Safety Research

More information

Influence of speed on gait parameters and on symmetry in transtibial

Influence of speed on gait parameters and on symmetry in transtibial Prosthetics and Orthotics International, 1996, 20, 153-158 Influence of speed on gait parameters and on symmetry in transtibial amputees E. ISAKOV*, H. BURGER**, J. KRAJNIK**, M. GREGORIC** and C. MARINCEK**

More information

Gait Analysis System. User Manual and Outcome parameters Patent WO2012/ A1

Gait Analysis System. User Manual and Outcome parameters Patent WO2012/ A1 Gait Analysis System User Manual and Outcome parameters Patent WO212/7855 A1 Thank you for purchasing our Gait Analysis Package. Gait Up s goal is to provide you with a user-friendly setup to measure accurately

More information

Fall Prevention Midterm Report. Akram Alsamarae Lindsay Petku 03/09/2014 Dr. Mansoor Nasir

Fall Prevention Midterm Report. Akram Alsamarae Lindsay Petku 03/09/2014 Dr. Mansoor Nasir Fall Prevention Midterm Report Akram Alsamarae Lindsay Petku 03/09/2014 Dr. Mansoor Nasir Updates to timeline Last semester we created a timeline that included important milestones. We have narrowed down

More information

Disability assessment using visual gait analysis

Disability assessment using visual gait analysis Disability assessment using visual gait analysis Sherif El-Sayed Hussein Computer and Systems Department, Mansoura University, Mansoura, Egypt Tel: +2 0122205369 Fax: +2 0502244690 E-mail: sherif_hussein@mans.edu.eg

More information

APPLICATION OF THREE DIMENSIONAL ACCELEROMETRY TO HUMAN MOTION ANALYSIS

APPLICATION OF THREE DIMENSIONAL ACCELEROMETRY TO HUMAN MOTION ANALYSIS APPLICATION OF THREE DIMENSIONAL ACCELEROMETRY TO HUMAN MOTION ANALYSIS INTRODUCTION Ken'ichi Egawa, T. Tsuboi, T. Satoh, and M. Miyazaki Graduate School of Human Sciences, Waseda University Three dimensional

More information

The Influence of Load Carrying Modes on Gait variables of Healthy Indian Women

The Influence of Load Carrying Modes on Gait variables of Healthy Indian Women The Influence of Load Carrying Modes on Gait variables of Healthy Indian Women *Guha Thakurta A, Iqbal R and De A National Institute of Industrial Engineering, Powai, Vihar Lake, Mumbai-400087, India,

More information

1 INEGI Instituto de Engenharia Mecânica e Gestão Industrial, Porto, Portugal, FEUP Faculdade de Engenharia,

1 INEGI Instituto de Engenharia Mecânica e Gestão Industrial, Porto, Portugal, FEUP Faculdade de Engenharia, REGISTRATION BETWEEN DATA FROM VISUAL SENSORS AND FORCE PLATFORM IN GAIT EVENT DETECTION Sousa, Daniela Sofia S., Tavares, João Manuel R. S., Correia, Miguel V., Mendes, Emília, Veloso, António 4, Silva,

More information

WHAT CAN WE LEARN FROM COMPETITION ANALYSIS AT THE 1999 PAN PACIFIC SWIMMING CHAMPIONSHIPS?

WHAT CAN WE LEARN FROM COMPETITION ANALYSIS AT THE 1999 PAN PACIFIC SWIMMING CHAMPIONSHIPS? WHAT CAN WE LEARN FROM COMPETITION ANALYSIS AT THE 1999 PAN PACIFIC SWIMMING CHAMPIONSHIPS? Bruce Mason and Jodi Cossor Biomechanics Department, Australian Institute of Sport, Canberra, Australia An analysis

More information

SCHEINWORKS Measuring and Analysis Systems by

SCHEINWORKS Measuring and Analysis Systems by Pressure Measurement Systems for standing and walking analysis Germany since 1879 Pressure Measurement Systems for standing and walking analysis Documentation of Gait image Stance Symmetry of all parameters

More information

3 people 3 unique lifestyles 3 advanced foot solutions

3 people 3 unique lifestyles 3 advanced foot solutions 3 people 3 unique lifestyles 3 advanced foot solutions Reclaim your life Information for practitioners Shelby Hans Intelligent feet are made for more than just walking Today s advanced microprocessor controlled

More information

PURPOSE. METHODS Design

PURPOSE. METHODS Design 7 Murrary, M.P.; Sepic, S.B.; Gardner, G.M.; and Mollinger, L.A., "Gait patterns of above-knee amputees using constant-friction knee components," Bull Prosthet Res, 17(2):35-45, 1980. 8 Godfrey, C.M.;

More information

Title: Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women

Title: Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women Author's response to reviews Title: Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women Authors: Tarja I Kinnunen (tarja.kinnunen@ncl.ac.uk)

More information

Using Accelerometry: Methods Employed in NHANES

Using Accelerometry: Methods Employed in NHANES Using Accelerometry: Methods Employed in NHANES Richard Troiano, Ph.D. David Berrigan, Ph.D. National Cancer Institute Overview NHANES Accelerometry Accelerometry Analytic Issues Decisions and data cleaning

More information

Novel empirical correlations for estimation of bubble point pressure, saturated viscosity and gas solubility of crude oils

Novel empirical correlations for estimation of bubble point pressure, saturated viscosity and gas solubility of crude oils 86 Pet.Sci.(29)6:86-9 DOI 1.17/s12182-9-16-x Novel empirical correlations for estimation of bubble point pressure, saturated viscosity and gas solubility of crude oils Ehsan Khamehchi 1, Fariborz Rashidi

More information

Impact Points and Their Effect on Trajectory in Soccer

Impact Points and Their Effect on Trajectory in Soccer Proceedings Impact Points and Their Effect on Trajectory in Soccer Kaoru Kimachi 1, *, Sungchan Hong 2, Shuji Shimonagata 3 and Takeshi Asai 2 1 Doctoral Program of Coaching Science, University of Tsukuba,

More information

Spasticity in gait. Wessex ACPIN Spasticity Presentation Alison Clarke

Spasticity in gait. Wessex ACPIN Spasticity Presentation Alison Clarke Spasticity in gait Clinicians recognise spasticity but the elements of spasticity contributing to gait patterns are often difficult to identify: Variability of muscle tone Observation/recording General

More information

Towards determining absolute velocity of freestyle swimming using 3-axis accelerometers

Towards determining absolute velocity of freestyle swimming using 3-axis accelerometers Towards determining absolute velocity of freestyle swimming using 3-axis accelerometers Author Stamm, Andy, Thiel, David, Burkett, Brendan, James, Daniel Published 2011 Journal Title Procedia Engineering

More information

Sanne W. T. Frazer, MSc 1,2, Willem E. H. Hellebrand, PT 3 and Noël L. W. Keijsers, PhD 1

Sanne W. T. Frazer, MSc 1,2, Willem E. H. Hellebrand, PT 3 and Noël L. W. Keijsers, PhD 1 J Rehabil Med 2013; 45: 848 853 ORIGINAL REPORT Variation and achievement of ambulatory activity among patients with chronic stroke Sanne W. T. Frazer, MSc 1,2, Willem E. H. Hellebrand, PT 3 and Noël L.

More information

Keywords. Electronic supplementary material

Keywords. Electronic supplementary material 1 de 6 A protocol named Outwalk was recently proposed to measure the thorax pelvis and lower-limb kinematics during gait in free-living conditions, by means of an inertial and magnetic measurement system

More information

Timed walking tests correlate with daily step activity in individuals with stroke.

Timed walking tests correlate with daily step activity in individuals with stroke. 1 Predicting daily step activity 2 3 Timed walking tests correlate with daily step activity in individuals with stroke. 4 5 6 Preliminary data were presented at the Australian Physiotherapy Association

More information

What is the optimal design of a rocker shoe

What is the optimal design of a rocker shoe What is the optimal design of a rocker shoe University of Salford School of Health, Sport and Rehabilitation Sciences Deutsche Sporthochschule Köln J Chapman, S Preece, C Nester, B Braunstein, P Bruggerman

More information

ASSESMENT Introduction REPORTS Running Reports Walking Reports Written Report

ASSESMENT Introduction REPORTS Running Reports Walking Reports Written Report ASSESMENT REPORTS Introduction Left panel Avatar Playback Right Panel Patient Gait Parameters Report Tab Click on parameter to view avatar at that point in time 2 Introduction Software will compare gait

More information

Open Research Online The Open University s repository of research publications and other research outputs

Open Research Online The Open University s repository of research publications and other research outputs Open Research Online The Open University s repository of research publications and other research outputs Developing an intelligent table tennis umpiring system Conference or Workshop Item How to cite:

More information

From early rehab to full recovery RHEO KNEE XC. go anywhere

From early rehab to full recovery RHEO KNEE XC. go anywhere From early rehab to full recovery RHEO KNEE XC go anywhere FROM EARLY REHAB TO FULL RECOVERY, GO ANYWHERE The capabilities that make RHEO KNEE XC dynamic for work and home also make it safe and effective

More information

Denny Wells, Jacqueline Alderson, Kane Middleton and Cyril Donnelly

Denny Wells, Jacqueline Alderson, Kane Middleton and Cyril Donnelly 11:45 am-12:00 pm Denny Wells. Assessing the accuracy of inverse kinematics in OpenSim to estimate elbow flexionextension during cricket bowling: Maintaining the rigid linked assumption. (201) ASSESSING

More information

Validated assessment of gait sub-phase durations in older adults using an accelerometer-based ambulatory system

Validated assessment of gait sub-phase durations in older adults using an accelerometer-based ambulatory system Validated assessment of gait sub-phase durations in older adults using an accelerometer-based ambulatory system Mohamed Boutaayamou 1,2, Sophie Gillain 3, Cédric Schwartz 1, Vincent Denoël 1, Jean Petermans

More information

QUANTIFYING AFL PLAYER GAME DEMANDS USING GPS TRACKING. Ben Wisbey and Paul Montgomery FitSense Australia

QUANTIFYING AFL PLAYER GAME DEMANDS USING GPS TRACKING. Ben Wisbey and Paul Montgomery FitSense Australia QUANTIFYING AFL PLAYER GAME DEMANDS USING GPS TRACKING Ben Wisbey and Paul Montgomery FitSense Australia Table of Contents Introduction... 3 Methods... 4 Statistical measures... 5 GPS Accuracy... 5 Results...

More information

Validity of Four Activity Monitors during Controlled and Free-Living Conditions

Validity of Four Activity Monitors during Controlled and Free-Living Conditions Illinois State University ISU ReD: Research and edata Theses and Dissertations 8-27-2013 Validity of Four Activity Monitors during Controlled and Free-Living Conditions Joey Lee Illinois State University,

More information

Available online at ScienceDirect. Procedia Computer Science 76 (2015 )

Available online at  ScienceDirect. Procedia Computer Science 76 (2015 ) Available online at www.sciencedirect.com ScienceDirect Procedia Computer Science 76 (2015 ) 257 263 2015 IEEE International Symposium on Robotics and Intelligent Sensors (IRIS 2015) Walking-Assisted Gait

More information

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Available online at  ScienceDirect. Procedia Engineering 112 (2015 ) Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 112 (2015 ) 540 545 7th Asia-Pacific Congress on Sports Technology, APCST 2015 Movement variability of professional pool billiards

More information

Mutual and asynchronous anticipation and action in sports as globally competitive

Mutual and asynchronous anticipation and action in sports as globally competitive 1 Supplementary Materials Mutual and asynchronous anticipation and action in sports as globally competitive and locally coordinative dynamics Keisuke Fujii, Tadao Isaka, Motoki Kouzaki and Yuji Yamamoto.

More information

measures Second generation accelerometers

measures Second generation accelerometers Accelerometer issues SINGLE-SITE PLACEMENT; waist placement -> PA underestimate during upper limb movement, standing, vertical activity (i.e., climbing stairs, uphill walking), pushing or pulling objects,

More information

Real-Time Smoothness Measurements on Concrete Pavements During Construction

Real-Time Smoothness Measurements on Concrete Pavements During Construction Recommended Practice for Real-Time Smoothness Measurements on Concrete Pavements During Construction XX-## (2017) 1. SCOPE 1.1. This document provides language that can be used by an Owner-Agency to develop

More information

Evaluation of a commercially available

Evaluation of a commercially available Loughborough University Institutional Repository Evaluation of a commercially available pedometer used to promote physical activity as part of a national programme This item was submitted to Loughborough

More information

The validity of a non-differential global positioning system for assessing player movement patterns in field hockey

The validity of a non-differential global positioning system for assessing player movement patterns in field hockey Journal of Sports Sciences, January 15th 2009; 27(2): 121 128 The validity of a non-differential global positioning system for assessing player movement patterns in field hockey HANNAH MACLEOD 1, JOHN

More information

Empower. Reclaim your power. Information for technicians. Empower Ottobock 1

Empower. Reclaim your power. Information for technicians. Empower Ottobock 1 Empower Reclaim your power. Information for technicians Empower Ottobock 1 Empower Powered propulsion for more freedom in life The Empower is an innovation in the field of prosthetic feet. It is equipped

More information

Clinical view on ambulation in patients with Spinal Cord Injury

Clinical view on ambulation in patients with Spinal Cord Injury Clinical view on ambulation in patients with Spinal Cord Injury Sasa Moslavac Spinal Unit, Special Medical Rehabilitation Hospital, Varazdinske Toplice,, Croatia 1 Spinal Cord Injury (SCI) to walk again

More information

MEASUREMENTS OF TEMPORAL and spatial gait parameters

MEASUREMENTS OF TEMPORAL and spatial gait parameters 1648 ORIGINAL ARTICLE Agreement Between the GAITRite Walkway System and a Stopwatch Footfall Count Method for Measurement of Temporal and Spatial Gait Parameters James W. Youdas, PT, MS, John H. Hollman,

More information

Inter and intra-limb processes of gait control.

Inter and intra-limb processes of gait control. Inter and intra-limb processes of gait control. Simon B. Taylor, Rezaul K. Begg and Russell J. Best Biomechanics Unit, Centre for Rehabilitation, Exercise and Sport Science. Victoria University, Melbourne,

More information

Knee Kinematic Improvement after Total Knee Replacement Using a Simplified Quantitative Gait Analysis Method

Knee Kinematic Improvement after Total Knee Replacement Using a Simplified Quantitative Gait Analysis Method Iranian Rehabilitation Journal, Vol. 11, No. 18, October 2013 Original Article Knee Kinematic Improvement after Total Knee Replacement Using a Simplified Quantitative Gait Analysis Method Hassan Sarailoo

More information

Salisbury District Hospital

Salisbury District Hospital The Effectiveness of Peroneal Nerve Functional Electrical STimulation (FES) for the Reduction of Bradykinesia in Parkinson s Disease: A Pragmatic Two Site Feasibility Study for a Single Blinded Randomised

More information

The effect of different backpack loading systems on trunk forward lean angle during walking among college students

The effect of different backpack loading systems on trunk forward lean angle during walking among college students Available online at www.scholarsresearchlibrary.com European Journal of Sports and Exercise Science, 2012, 1 (1):1-5 (http://scholarsresearchlibrary.com/archive.html) ISSN: 2278 005X The effect of different

More information

Analysis of stroke technique using acceleration sensor IC in freestyle swimming

Analysis of stroke technique using acceleration sensor IC in freestyle swimming Analysis of stroke technique using acceleration sensor IC in freestyle swimming Y. Ohgi, M. Yasumura Faculty of Environmental Information, Keio Univ., Japan H. Ichikawa Doctoral Prog. of Health and Sport

More information

Module 3 Developing Timing Plans for Efficient Intersection Operations During Moderate Traffic Volume Conditions

Module 3 Developing Timing Plans for Efficient Intersection Operations During Moderate Traffic Volume Conditions Module 3 Developing Timing Plans for Efficient Intersection Operations During Moderate Traffic Volume Conditions CONTENTS (MODULE 3) Introduction...1 Purpose...1 Goals and Learning Outcomes...1 Organization

More information

Using GPOPS-II to optimize sum of squared torques of a double pendulum as a prosthesis leg. Abstract

Using GPOPS-II to optimize sum of squared torques of a double pendulum as a prosthesis leg. Abstract Using GPOPS-II to optimize sum of squared torques of a double pendulum as a prosthesis leg Abstract Milad Zarei MCE 593 Prosthesis Design & Control A two-dimensional, two links pendulum is developed to

More information

Accelerometers: An Underutilized Resource in Sports Monitoring

Accelerometers: An Underutilized Resource in Sports Monitoring Accelerometers: An Underutilized Resource in Sports Monitoring Author Neville, Jono, Wixted, Andrew, Rowlands, David, James, Daniel Published 2010 Conference Title Proceedings of the 2010 Sixth International

More information

Foot side detection from lower lumbar spine acceleration

Foot side detection from lower lumbar spine acceleration This is an Author's Original Manuscript of an article published by Elsevier in Gait and Posture Published online 6 June 2015 and available at: doi:10.1016/j.gaitpost.2015.05.021 Foot side detection from

More information

Learning Locomotion Test 3.1 Results

Learning Locomotion Test 3.1 Results Learning Locomotion Test 3.1 Results TABLE OF CONTENTS 1 INTRODUCTION... 2 2 TEST METHODS... 2 2.1 TEST COURSES... 2 2.2 COMMUNICATIONS... 3 2.3 APPLICABLE DOCUMENTS... 3 3 RESULTS: TYPE A TESTS... 3 3.1

More information

Video Based Accurate Step Counting for Treadmills

Video Based Accurate Step Counting for Treadmills Proceedings Video Based Accurate Step Counting for Treadmills Qingkai Zhen, Yongqing Liu, Qi Hu and Qi Chen * Sport Engineering Center, China Institute of Sport Science, Beijing 100061, China; zhenqingkai@ciss.cn

More information

Validity and Reproducibility of the Garmin Vector Power Meter When Compared to the SRM Device

Validity and Reproducibility of the Garmin Vector Power Meter When Compared to the SRM Device Journal of Sports Science 5 (2017) 235-241 doi: 10.17265/2332-7839/2017.05.001 D DAVID PUBLISHING Validity and Reproducibility of the Garmin Vector Power Meter When Compared to the SRM Device Randolph

More information

empower Reclaim your power. Information for technicians empower Ottobock 1

empower Reclaim your power. Information for technicians empower Ottobock 1 empower Reclaim your power. Information for technicians empower Ottobock 1 empower Powered propulsion for more freedom in life The empower Ankle is an innovation in the field of prosthetic feet. It is

More information

Health & Fitness Journal

Health & Fitness Journal Health & Fitness Journal of Canada Copyright 2012 The Authors. Journal Compilation Copyright 2012 Health & Fitness Program of BC Volume 5 December 30, 2012 Number 4! ORIGINAL!ARTICLE! Is!this!Bit!Fit?!Measuring!the!Quality!of!the!FitBit!StepACounter!

More information

save percentages? (Name) (University)

save percentages? (Name) (University) 1 IB Maths Essay: What is the correlation between the height of football players and their save percentages? (Name) (University) Table of Contents Raw Data for Analysis...3 Table 1: Raw Data...3 Rationale

More information

KINEMATIC QUANTIFICATION OF GAIT SYMMETRY BASED ON BILATERAL CYCLOGRAMS

KINEMATIC QUANTIFICATION OF GAIT SYMMETRY BASED ON BILATERAL CYCLOGRAMS KINEMATIC QUANTIFICATION OF GAIT SYMMETRY BASED ON BILATERAL CYCLOGRAMS Ambarish Goswami Honda Research Institute Mountain View, California, USA agoswami@honda-ri.com Abstract Symmetry is considered to

More information

The Effects of Simulated Knee Arthrodesis and Temporal Acclimation on Gait Kinematics

The Effects of Simulated Knee Arthrodesis and Temporal Acclimation on Gait Kinematics The Effects of Simulated Knee Arthrodesis and Temporal Acclimation on Gait Kinematics Eric M. Lucas, MS 1, Randy Hutchison, PhD 2, Justin Marro, MS 1, Taylor Gambon 1, John D. DesJardins, PhD 1. 1 Clemson

More information

Sprint Hurdles SPRINT HURDLE RACES: A KINEMATIC ANALYSIS

Sprint Hurdles SPRINT HURDLE RACES: A KINEMATIC ANALYSIS Sprint Hurdles SPRINT HURDLE RACES: A KINEMATIC ANALYSIS By Pierre-Jean Vazel, December 2011 In order to prescribe the most effective training possible it is important for coaches to have a sound understanding

More information

The overarching aim of the work presented in this thesis was to assess and

The overarching aim of the work presented in this thesis was to assess and CHAPTER 7 EPILOGUE Chapter 7 The overarching aim of the work presented in this thesis was to assess and understand the effort for balance control in terms of the metabolic cost of walking in able-bodied

More information

Abstract. Ulrik Röijezon, PhD and Paul Arden, MCCI

Abstract. Ulrik Röijezon, PhD and Paul Arden, MCCI Evaluation of long distance casting performance a comparison between three fly line prototypes and a commercially available long belly floating line #5 Ulrik Röijezon, PhD and Paul Arden, MCCI Abstract

More information

INFLUENCE OF PEDOMETER TILT ANGLE ON STEP COUNTING VALIDITY DURING CONTROLLED TREADMILL WALKING TRIALS. Melissa Dock

INFLUENCE OF PEDOMETER TILT ANGLE ON STEP COUNTING VALIDITY DURING CONTROLLED TREADMILL WALKING TRIALS. Melissa Dock INFLUENCE OF PEDOMETER TILT ANGLE ON STEP COUNTING VALIDITY DURING CONTROLLED TREADMILL WALKING TRIALS by Melissa Dock A thesis submitted in partial fulfillment of the requirements for the degree of Master

More information

Influence of Angular Velocity of Pedaling on the Accuracy of the Measurement of Cyclist Power

Influence of Angular Velocity of Pedaling on the Accuracy of the Measurement of Cyclist Power Influence of Angular Velocity of Pedaling on the Accuracy of the Measurement of Cyclist Power Abstract Almost all cycling power meters currently available on the market are positioned on rotating parts

More information

Procedia Engineering Procedia Engineering 2 (2010)

Procedia Engineering Procedia Engineering 2 (2010) Available online at www.sciencedirect.com Procedia Engineering Procedia Engineering 2 (2010) 002681 2686 (2009) 000 000 Procedia Engineering www.elsevier.com/locate/procedia 8 th Conference of the International

More information

VISUOMOTOR CONTROL OF STRAIGHT AND BREAKING GOLF PUTTS 1

VISUOMOTOR CONTROL OF STRAIGHT AND BREAKING GOLF PUTTS 1 Perceptual and Motor Skills, 2009, 109, 555-562. Perceptual and Motor Skills 2009 VISUOMOTOR CONTROL OF STRAIGHT AND BREAKING GOLF PUTTS 1 MARK R. WILSON AND RICHARD C. PEARCY University of Exeter Summary.

More information

Basic walker-assisted gait characteristics derived from forces and moments exerted on the walker s handles: Results on normal subjects

Basic walker-assisted gait characteristics derived from forces and moments exerted on the walker s handles: Results on normal subjects Medical Engineering & Physics 29 (2007) 380 389 Basic walker-assisted gait characteristics derived from forces and moments exerted on the walker s handles: Results on normal subjects Majd Alwan a,, Alexandre

More information

COMPARISON OF BIOMECHANICAL DATA OF A SPRINT CYCLIST IN THE VELODROME AND IN THE LABORATORY

COMPARISON OF BIOMECHANICAL DATA OF A SPRINT CYCLIST IN THE VELODROME AND IN THE LABORATORY COMPARISON OF BIOMECHANICAL DATA OF A SPRINT CYCLIST IN THE VELODROME AND IN THE LABORATORY Louise Burnie 1,2, Paul Barratt 3, Keith Davids 1, Paul Worsfold 2,4, Jon Wheat 1 Centre for Sports Engineering

More information

REPLACING REDUNDANT STABILOMETRY PARAMETERS WITH RATIO AND MAXIMUM DEVIATION PARAMETERS

REPLACING REDUNDANT STABILOMETRY PARAMETERS WITH RATIO AND MAXIMUM DEVIATION PARAMETERS Proceedings of the 12th IASTED International Conference Biomedical Engineering (BioMed 2016) February 15-16, 2016 Innsbruck, Austria REPLACING REDUNDANT STABILOMETRY PARAMETERS WITH RATIO AND MAXIMUM DEVIATION

More information

ScienceDirect. Rebounding strategies in basketball

ScienceDirect. Rebounding strategies in basketball Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 72 ( 2014 ) 823 828 The 2014 conference of the International Sports Engineering Association Rebounding strategies in basketball

More information

The Effects of the Deflection Point and Shaft Mass on Swing and Launch Parameters in the Golf Swing

The Effects of the Deflection Point and Shaft Mass on Swing and Launch Parameters in the Golf Swing Edith Cowan University Research Online ECU Publications 202 202 The Effects of the Deflection Point and Shaft Mass on Swing and Launch Parameters in the Golf Swing Christopher Joyce Edith Cowan University

More information

NIH Public Access Author Manuscript Gait Posture. Author manuscript; available in PMC 2009 May 1.

NIH Public Access Author Manuscript Gait Posture. Author manuscript; available in PMC 2009 May 1. NIH Public Access Author Manuscript Published in final edited form as: Gait Posture. 2008 May ; 27(4): 710 714. Two simple methods for determining gait events during treadmill and overground walking using

More information

Effect of walking speed and placement position interactions in determining the accuracy of various newer pedometers

Effect of walking speed and placement position interactions in determining the accuracy of various newer pedometers Available online at www.sciencedirect.com ScienceDirect Journal of Exercise Science & Fitness 12 (214) 31e37 Original article Effect of walking speed and placement position interactions in determining

More information

Equine Cannon Angle System

Equine Cannon Angle System Equine Cannon System How to interpret the results December 2010 Page 1 of 14 Table of Contents Introduction... 3 The Sagittal Plane... 4 The Coronal Plane... 5 Results Format... 6 How to Interpret the

More information

The Promise of Achieving Higher Standards in Children s Health. The Gait and Motion Analysis Laboratory Referral Guide

The Promise of Achieving Higher Standards in Children s Health. The Gait and Motion Analysis Laboratory Referral Guide The Promise of Achieving Higher Standards in Children s Health Nemours/Alfred I. dupont Hospital for Children has consistently been ranked among the best in the nation for pediatric orthopedics by U.S

More information

Presence and duration of reactivity to pedometers in adults

Presence and duration of reactivity to pedometers in adults Loughborough University Institutional Repository Presence and duration of reactivity to pedometers in adults This item was submitted to Loughborough University's Institutional Repository by the/an author.

More information

GAIT MEASUREMENTS AND MOTOR RECOVERY AFTER STROKE. Plamen S. Mateev, Ina M. Tarkka, Ekaterina B. Titianova

GAIT MEASUREMENTS AND MOTOR RECOVERY AFTER STROKE. Plamen S. Mateev, Ina M. Tarkka, Ekaterina B. Titianova Pliska Stud. Math. Bulgar. 16 (2004), 121-128 STUDIA MATHEMATICA BULGARICA GAIT MEASUREMENTS AND MOTOR RECOVERY AFTER STROKE Plamen S. Mateev, Ina M. Tarkka, Ekaterina B. Titianova Gait analysis is one

More information

KOTARO SASAKI Curriculum Vitae

KOTARO SASAKI Curriculum Vitae KOTARO SASAKI Curriculum Vitae Department of Mechanical & Biomedical Engineering Boise State University 1910 University Dr. Boise ID 83725-2075 Phone: (208) 426-4027 Email: kosasaki@boisestate.edu EDUCATION

More information

PUBLISHED PROJECT REPORT PPR850. Optimisation of water flow depth for SCRIM. S Brittain, P Sanders and H Viner

PUBLISHED PROJECT REPORT PPR850. Optimisation of water flow depth for SCRIM. S Brittain, P Sanders and H Viner PUBLISHED PROJECT REPORT PPR850 Optimisation of water flow depth for SCRIM S Brittain, P Sanders and H Viner Report details Report prepared for: Project/customer reference: Copyright: Highways England,

More information

Spatial Methods for Road Course Measurement

Spatial Methods for Road Course Measurement Page 1 of 10 CurtinSearch Curtin Site Index Contact Details Links LASCAN Spatial Sciences WA Centre for Geodesy COURSE MEASUREMENT This page is a summary of results of some of the research we have recently

More information

WindProspector TM Lockheed Martin Corporation

WindProspector TM Lockheed Martin Corporation WindProspector TM www.lockheedmartin.com/windprospector 2013 Lockheed Martin Corporation WindProspector Unparalleled Wind Resource Assessment Industry Challenge Wind resource assessment meteorologists

More information

Key words: biomechanics, injury, technique, measurement, strength, evaluation

Key words: biomechanics, injury, technique, measurement, strength, evaluation Becker, T., & Havriluk, R. (2006). Bilateral and anterior-posterior muscular imbalances in swimmers. In J. P. Vilas-Boas, F. Alves, A. Marques (Eds.), Biomechanics and Medicine in Swimming X. Portuguese

More information

A New Approach to Modeling Vertical Stiffness in Heel-Toe Distance Runners

A New Approach to Modeling Vertical Stiffness in Heel-Toe Distance Runners Brigham Young University BYU ScholarsArchive All Faculty Publications 2003-12-01 A New Approach to Modeling Vertical Stiffness in Heel-Toe Distance Runners Iain Hunter iain_hunter@byu.edu Follow this and

More information

The Incremental Evolution of Gaits for Hexapod Robots

The Incremental Evolution of Gaits for Hexapod Robots The Incremental Evolution of Gaits for Hexapod Robots Abstract Gait control programs for hexapod robots are learned by incremental evolution. The first increment is used to learn the activations required

More information

1B1 Meridium. Reclaim your way. Information for practitioners. Meridium Ottobock 1

1B1 Meridium. Reclaim your way. Information for practitioners. Meridium Ottobock 1 1B1 Meridium Reclaim your way. Information for practitioners Meridium Ottobock 1 Reclaim your way. With the development of the individualized Meridium prosthetic foot, Ottobock has incorporated the latest

More information

Mobility Lab provides sensitive, valid and reliable outcome measures.

Mobility Lab provides sensitive, valid and reliable outcome measures. Mobility Lab provides sensitive, valid and reliable outcome measures. ith hundreds of universities and hospitals using this system worldwide, Mobility Lab is the most trusted wearable gait and balance

More information

Factors of Influence on the Walking Ability of Children with Spastic Cerebral Palsy

Factors of Influence on the Walking Ability of Children with Spastic Cerebral Palsy Factors of Influence on the Walking Ability of Children with Spastic Cerebral Palsy J. Phys. Ther. Sci. 10: 1 5, 1998 ATSUSHI FURUKAWA, RPT 1), EIJI NII, MD, PhD 1), HIROYASU IWATSUKI, RPT 2), MASAKI NISHIYAMA,

More information