1 Control Valves, Fittings and Accessories INTERNATIONAL WS2H* 47 lpm 125 gpm WS2CI 45 lpm 115 gpm WS2EI 45 lpm 115 gpm WS1.5CI 227 lpm 60 gpm WS1.5EI 227 lpm 60 gpm WS1.25* 129 lpm 4 gpm WS1.25CI* 129 lpm 4 gpm WS1.25EI* 129 lpm 4 gpm WS1.25TC* 129 lpm 4 gpm WS1* 102 lpm 27 gpm WS1CI* 102 lpm 27 gpm WS1EI* 102 lpm 27 gpm WS1TC* 102 lpm 27 gpm *Valves shown with optional bypass.
2 INTERNATIONAL 1 Water Specialist Valve Specifications SPECIFICATIONS WS1 - USA ONLY WS1CI 1 bar/15 psi drop 1.7 bar/25 psi drop Tank Applications: Softener Filter (1) Inlet/Outlet Fitting Connections 102 lpm (includes meter and bypass) 102 lpm (includes bypass) Male BSPT Sweat Solvent 102 lpm (includes meter and bypass) 102 lpm (includes bypass) Male BSPT Sweat Solvent Valve Material Cycles Regeneration Operating Pressures Operating Temperatures Meter: Flow Rate Range Volume Range (cubic meters) Totalizer /Upflow 4-4 C lpm m Up to 9 /Upflow 4-4 C lpm m Distributor Pilot O.D. Pipe O.D. Pipe Drain Line Connection Brine Line Connection 4 Male NPT Standard 8 or 1 2 O.D. 4 Male NPT Standard 8 or 1 2 O.D. Mounting Base Options NPSM NPSM Height From Top of Tank 187mm 187mm Shipping Weight 2 Kg 2 Kg Electrical: Supply Voltage Supply Frequency Output Voltage Output Current 20V AC 20V AC 1. Filter tank size 407 lpm per m 2 of bed area/10 gpm of backwash per square foot of bed area 2. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company
3 1 Water Specialist Valve Specifications WS1EI 102 lpm (includes meter and bypass) 102 lpm (includes bypass) Male BSPT Sweat Solvent 4-4 C WS1TC 102 lpm (includes meter and bypass) 102 lpm (includes bypass) Male BSPT Sweat Solvent 4-4 C lpm m Not Applicable O.D. Pipe O.D. Pipe 4 Male NPT Standard 8 or 1 2 O.D. 4 Male NPT Standard 8 or 1 2 O.D NPSM NPSM 187mm 187mm 2 Kg 2 Kg 20V AC 20V AC Valves shown with optional bypass.
4 INTERNATIONAL 1.25 Water Specialist Valve Specifications SPECIFICATIONS WS USA ONLY WS1.25CI 1 bar/15 psi drop 1.7 bar/25 psi drop Tank Applications: Softener Filter (1) Inlet/Outlet Fitting Connections Valve Material Cycles Regeneration Operating Pressures Operating Temperatures Meter: Flow Rate Range Volume Range (cubic meters) Totalizer 129 lpm (includes meter and bypass) 121 lpm (includes bypass) 6-24 diameter / Male BSPT /4-1.5 Sweat /4-1.5 Solvent 4-4 C lpm m 129 lpm (includes meter and bypass) 121 lpm (includes bypass) 6-24 diameter / Male BSPT /4-1.5 Sweat /4-1.5 Solvent Up to C lpm m Distributor Pilot 2mm O.D. Pipe 2mm O.D. Pipe Drain Line Connection Brine Line Connection /4 Male NPT Standard /8 or 1/2 O.D. /4 Male NPT Standard /8 or 1/2 O.D. Mounting Base Options 2-1/2-8 NPSM 2-1/2-8 NPSM Height From Top of Tank 187mm 187mm Shipping Weight w/meter 2 Kg 2 Kg Electrical: Supply Voltage Supply Frequency Output Voltage Output Current 20V AC 20V AC 1. Filter tank size 407 lpm per m 2 of bed area/10 gpm of backwash per square foot of bed area 2. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company
5 1.25 Water Specialist Valve Specifications WS1.25EI 129 lpm (includes meter and bypass) 121 lpm (includes bypass) 6-24 diameter / Male BSPT /4-1.5 Sweat /4-1.5 Solvent 4-4 C 129 lpm (includes bypass) 121 lpm (includes bypass) 6-24 diameter / Male BSPT /4-1.5 Sweat /4-1.5 Solvent 4-4 C WS1.25TC lpm m 2mm O.D. Pipe /4 Male NPT Standard /8 or 1/2 O.D. Not Applicable 2mm O.D. Pipe /4 Male NPT Standard /8 or 1/2 O.D. 2-1/2-8 NPSM 2-1/2-8 NPSM 187mm 187mm 2 Kg 2 Kg 20V AC 20V AC Valves shown with optional bypass.
6 INTERNATIONAL 1.5 Water Specialist Valve Specifications SPECIFICATIONS WS1.5CI WS1.5EI 1 bar/15 psi drop 1.7 bar/25 psi drop Tank Applications: Softener Filter (1) Inlet/Outlet Fitting Connections 227 lpm (includes meter) 189 lpm diameter 12-0 diameter 227 lpm (includes meter) 189 lpm diameter 12-0 diameter 1.5 Female BSPT or NPT 1.5 Female BSPT or NPT Valve Material Cycles Regeneration Operating Pressures Operating Temperatures Meter: Flow Rate Range Volume Range Totalizer Lead Free Brass Up to C lpm m Lead Free Brass 4-4 C lpm m Distributor Pilot 50mm O.D. or 1.90 O.D. Pipe 50mm O.D. or 1.90 O.D. Pipe Drain Line Connection Brine Line Connection 1.25 Female NPT with 4 Male NPT Standard 4 Female NPT 1 2 O.D. Mounting Base Options 4-8 UN 4-8 UN 1.25 Female NPT with 4 Male NPT Standard 4 Female NPT 1 2 O.D. Height From Top of Tank 191mm 191mm Shipping Weight w/meter 9.5 Kg 9.5 Kg Electrical: Supply Voltage Supply Frequency Output Voltage Output Current 20V AC 20V AC 1. Filter tank size 407 lpm per m 2 of bed area/10 gpm of backwash per square foot of bed area 2. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company
7 2 Water Specialist Valve Specifications WS2CI WS2EI WS2H 45 lpm (includes meter) 0 lpm 45 lpm (includes meter) 0 lpm 47 lpm (includes meter) 47 lpm diameter 12-6 diameter diameter 12-6 diameter 18-6 diameter diameter 2 Female BSPT or NPT 2 Female BSPT or NPT 2 Female BSPT or NPT/ 2.5 Groove Lock Lead Free Brass Up to C Lead Free Brass 4-4 C Lead Free Brass Up to C lpm m lpm m lpm liters x mm O.D. or 1.90 O.D. Pipe 50mm O.D. or 1.90 O.D. Pipe 6mm O.D. or 2.75 O.D. Pipe 1.5 Female NPT 1.5 Female NPT 2 Female NPT/ 2.5 Groove Lock 1 Male NPT elbow 4 x 1 Solvent elbow 1 2 O.D. Poly Tube Compression 1 Male NPT elbow 4 x 1 Solvent elbow 1 2 O.D. Poly Tube Compression 1 Male NPT elbow 4 x 1 Solvent elbow 4-8 UN 4-8 UN Quick Disconnect 4-8 UN or 6 Flange or Side Mount 216mm 216mm 280mm 1 Kg 1 Kg 22.7 Kg 20V AC 20V AC 20V AC 24V AC 750 ma
8 1 & 1.25 Control Valve Fittings and Accessories 1 PVC Male NPT Elbow Assembly ¾ x 1 PVC Solvent Elbow Assembly 1 Brass Sweat Assembly Order No. V007 Order No. V Order No. V ¾ Brass Sweat Assembly 1 Plastic Male NPT Assembly 1.25 Plastic Male NPT Assembly Order No. V007-0 Order No. V Order No. V Plastic Male BSPT Assembly 1.25 & 1.5 PVC Solvent Assembly 1.25 Plastic Male BSPT Assembly Order No. V Order No. V Order No. V & 1.5 Brass Sweat Assembly Vertical 90 Adapter Kit Order No. V Order No. V191-01
9 1 & 1.25 Control Valve Fittings and Accessories ¾ SharkBite Assembly 1 SharkBite Assembly ¾ Plastic Male BSPT Assembly Order No. V Order No. V007-1 Order No. V Bypass 1 Straight DLFC w/silencer 1 M x M Straight DLFC Order No. V006 Order No. V Order No. V Straight DLFC without Silencer Auxiliary Microswitch Kit WS1 Series Microswitch Assembly Order V No. V Order No. V009 Order No. V014 Weather Covers Wrench Order No. V V175WC-W White Order No. V175WC-A Almond Order No. V19-02
10 1 & 1.25 Control Valve Fittings and Accessories 1 & 1.25 Motorized Alternating Valve 1 & 1.25 Motorized Alternating Valve Order No. V069FF F x F Order No. V069MM M x M 1 & 1.25 No Hard Water Bypass Valve 1 & 1.25 No Hard Water Bypass Valve Order No. V070FF F x F Order No. V070FM F x M
11 1 & 1.25 Control Valve Fittings and Accessories 1.5 Motorized Alternating Valve 2.0 Motorized Alternating Valve Order No. V071 NPT Order No. V071BSPT BSPT Order No. V06 NPT Order No. V06BSPT BSPT
12 DURAFORM LANE WINDSOR, WISCONSIN USA phone (608) fax (608) sales /customer service fax (800) Form No /20/2008
AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS
AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS TABLE OF CONTENTS TABLE OF CONTENTS...2 GENERAL RECOMMENDATIONS...2 TROUBLESHOOTING GUIDE...3 EXISTING EASY NEST SYSTEM TROUBLESHOOTING GUIDE...4 COMPONENT
More informationEasy Nest Kits. Installation Suggestions
Easy Nest Kits Installation Suggestions 2 General Recommendations Hydraulics Vacuum breakers should be installed to prevent siphoning. Flexible connectors should follow FRP tank manufacturers recommendations.
More informationAutotrol Performa Filter Valve Series
TM Autotrol Performa Filter Valve Series 440i Control 940F Control 960F Control Water Conditioning Control System Installation, Operation and Maintenance Manual Table of Contents Installation............................
More informationPerforma Cv Twin Alternating and High Flow Systems. Manual Supplement
Performa Cv Twin Alternating and High Flow Systems Manual Supplement Table of Contents 1.0 Installation and Start-Up.............. 3 Water Line Connection Brine Tank Turbine Connection Connecting Manifold
More informationInstallation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14
Installation and Instructions 2 Product Features 3-6 Key Pad Functions 7 Distributor Information Programming Guide 8 Master Programming Guide 9-14 Dimensional Drawing 15 D-STC & D-SMM Valve Assembly 16-17
More information265 Series Valve Operation Manual
265 Series Valve Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant
More informationFlow Material Length. Weight GPM LPM. Style 3095
Akron Municipal Eductors feature a large, easy to read, and removable metering dial with infinite settings between 0% and 6%. Detents at 1 4, 1 2, 1, 3 and 6%. The Eductors are rated to flow at 200 psi
More informationDRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank
Set Up Instructions for DRS4 Series Single Tank Inspect the packaging of the equipment to confirm that nothing was damaged during shipping. (Figure 1) Remove the resin tank(s) and valve(s) from the packaging.
More informationDuplex Commercial Softeners
Duplex Commercial Softeners Installation, Operation & Maintenance Guide Manual 003.1 Contents Page 1. Unpacking Instructions 3 2. Installation 4 Pre-installation checks Fitting the bottom distribution
More informationVERTICAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationTECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.
Page 1 of 8 1. DESCRIPTION A Viking Pilot Pressure Regulated Deluge System utilizes a Viking Flow Control Valve to control water flow into the deluge system. The flow control valve must be installed with
More informationCommercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1
Commercial Softeners Installation, Operation & Maintenance Guide Manual 002.1 Contents Page 1. Unpacking Instructions 3 2. Installation 3 Pre-installation checks Fitting the bottom distribution system
More informationTECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.
Page 1 of 8 1. DESCRIPTION A Viking Pilot Pressure Regulated Deluge System utilizes a Viking flow control valve to control water flow into the deluge system. The flow control valve must be installed with
More informationHORIZONTAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationTANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING
CONRADER VALVES TANK MATE AUTOMATIC DRAIN VALVE INSTALLATION KIT INCLUDES: TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING WV-1 DRAIN VALVE TOOLS REQUIRED: 3/4 WRENCH **TUBING CUTTERS ** NEEDED TO CUT METAL
More informationPrestige Water Equipment Ltd.
The Prestige range of water softeners complements the range of water pretreatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer
More informationSKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25
More informationChloramines Removal Filter CLF20 and CLF35 Models
Chloramines Removal Filter CLF20 and CLF35 Models Operating and Maintenance Manual #51793 Rev. 6/09 Performance and Specifications Recommended Mineral Installation Shipping Item Model Media Flow Rate Tank
More informationtable of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20
table of contents kitchen accessories Air Gaps.............3 Basket Strainers.........3 Disposal Flanges....... 3-4 Faucet Hole Covers....... 4 Soap & Lotion Dispensers.... 4 Water Dispensers........ 4
More informationWith 960 Series Control Water Conditioning Control System Installation, Operation and Maintenance Manual
With 960 Series Control Water Conditioning Control System Installation, Operation and Maintenance Manual Part# AP-5100 AP-5125 AP-5150 Manufactured by: Good Water Warehouse Inc. 1700 E. Walnut Ave Fullerton,
More informationINSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS
INSTALLATION & START-UP INSTRUCTIONS Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS 1999-2009 QualityWaterForLess.com - 1 - info@qualitywaterforless.com Preface: Thank you for your purchase of a new Water
More informationFIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:
LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are
More informationTech Manual Powerline Softener (PS) Series
Tech Manual Powerline Softener (PS) Series Models: PS 2161 PS 2465 PS 2472 PS 3072 PS 3657 PS 3672 PS 4272 PS 4872 Page - 1 TABLE OF CONTENTS General Information About this Manual...3 The Powerline Product
More informationWorkhorse 8 Oxygen System Model No 5665, 5673, 5679
11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse 8 Oxygen System Model No 5665, 5673, 5679 Part Number 1815 Revision B SeQual Technologies San Diego, CA USA Cautions,
More informationNORMAL OPERATING DISPLAYS GENERAL OPERATION
SunTapWat e rsys t e ms WS1Cl ac kwat e rsof t ne r Owne r smanual MAIN COMPONENTS Your water treatment system is a point of entry (POE) system composed of three components: A. The control valve and computer
More informationDistributor Catalog 2. Quick Connect 0.2 mm slot. Metric Connection. Wave Cyber ( Shanghai ) Co., Ltd.
Distributor Catalog 2 Quick Connect 0.2 mm slot Metric Connection www.wave-cyber.com Wave Cyber ( Shanghai ) Co., Ltd. TOP MOUNT 6 LATERAL (Φ35MM) DISTRIBUTOR (2 ~ 2 TANKS) QUICK CONNECTION ITEM PART DESCRIPTION
More informationO&M Receiving and Inspection. Storage of Water Treatment Media
O&M 105.1 Receiving and Inspection 1. Equipment should be checked against the Bill of Lading to verify that the number of pieces received matches those shipped. 2. Equipment should be carefully inspected
More informationTECHNICAL DATA. Page 1 of 12
Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control
More informationTECHNICAL DATA Q= C. Table 1 - Specifications
September 25, 2013 Pressure Regulation 537a 1. Description The Model B-3 Pilot Operated Pressure Control Valve is a factory assembled unit. The unit consists of a Model J-2 Halar coated Flow Control Valve,
More informationTECHNICAL DATA. Pressure Regulation 531a. April 24, 2009
April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking
More informationPVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION
PVC FASTTAP SADDLES PVC FASTTAP SADDLES for IPS Mains THE ULTIMATE CONNECTION OUTLET 3/4 IPS FEMALE SLIP OR 1 IPS MALE SLIP SOLVENT WELD 1 IPS FEMALE SLIP SOLVENT WELD 3/4 MPT 1 MPT 3/4 FPT MAIN 13/16
More informationUS Water Systems Synergy Model 9000/9100/9500 Service Manual
US Water Systems Synergy Model 9000/9100/9500 Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference IMPORTANT PLEASE READ: The information, specifications and illustrations
More informationOperation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax
Operation Manual Carbon Filtration 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2 Theory of Operation... 2 1.3 System Illustration...
More informationTECHNICAL DATA CAUTION
Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking
More informationSpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems
SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems 2 3 PSP-1500 SYSTEM DESCRIPTION Reverse Osmosis RO Reverse Osmosis utilizes the unique properties of a semi-permeable membrane to
More informationTECHNICAL DATA. Table 1 - Specifications
Page 1 of 6 1. DESCRIPTION Model A-3 Pilot Operated Pressure Control Valves are factory assembled units. Each unit consists of a Model H-2 Halar coated Flow Control Valve, a Speed Control Valve, a Model
More informationBuild Your Own Flamethrower Step-by-step Manual
Build Your Own Flamethrower Step-by-step Manual Table of Contents: Parts List.. page 1 Operation...page 6 Diagrams. pages 7-9 Parts list: Required: Air tank (large) Pressure washer gun with high-pressure
More informationWITH PUMPMASTER 3+3 PUMPS - 20 AND 50 Kg.
MOBILE GREASE UNITS WITH PUMPMASTER 3+3 PUMPS - AND Kg. 01 AIR OPERATED OIL PUMPS AND KITS Iquip modit iriuscidunt nos niam ver ip AIR OPERATED PISTON PUMPS FOR OIL AND LUBRICANTS............... 000...
More informationKEG PUMP. Range of Electric Keg Pumps
KP KEG PUMP Range of Electric Keg Pumps Electric Keg (Drum) Pumps for Grease KEG PUMP Versatile range of Interlube electric grease pumps for industrial and off-road applications The KP keg pump is available
More informationSIMPLAIR PIPING TOOL. JXT Company
SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.
More informationTribomatic II Powder Pump
Instruction Sheet P/N Tribomatic II Powder Pump WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation.
More informationCompact Transfer Pump
Munster Simms Engineering, better known under the product brand name Whale, is an independent company engaged in the design, manufacture, marketing and selling of pumps, valves, faucets and plumbing (water
More informationLEAK TROUBLESHOOTING
LEAK TROUBLESHOOTING If you suspect that your TMC isolation system is leaking (most often evidenced by going through air/nitrogen tanks too quickly), this guide will help you to find and fix the problem.
More informationTechnical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6
Equipment Affected Technical Bulletin LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6 Ford 4.2L V-6 powered tractors with LPG fuel systems. Part Description Discrepancy Fuel Pressure Lock-off
More informationTECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1
November 30, 1994 534 a 1. PRODUCT NAME VIKING 2" (50mm), 3" (75mm), 4" (100mm), 6" (150mm) 2. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone:
More informationCONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint
Super-rapid fittings for plastic tubes Series 6000 Sprint Tube external diameters: 3,, 5, 6, 8, 10, 12, 1, 16 mm Fittings threads: metric (M3, M5, M6, M7), BSP (G1/8, G1/, G3/8, G1/2, G3/), BSPT (R1/8,
More informationTECHNICAL DATA OBSOLETE
August 2, 2006 Foam 70a 1. DESCRIPTION A Hi-Expansion Foam System is a standard deluge system capable of discharging a foam/water solution automatically through open Hi-Ex Generators. A Hi-Expansion Foam
More informationMagnum Cv Series. Installation and Service Manual
Magnum Cv Series Installation and Service Manual Table of Contents Section 1.0 Installation Profile Summary - - - - - - - - - - - - - - - - - - - - - - - -1 2.0 Introduction to the Magnum Cv Series -
More informationLV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE
LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SPECIFICATIONS: 10 gpm (38 lpm) Nominal Capacity. Rated up to 4000 psi (275 bar). Port Sizes-Inlet/Outlet #8SAE (3/4-16). Work Ports #8SAE
More informationSeries 180. Commercial/Industrial Control System Installation, Operation and Maintenance Manual
Series 180 Commercial/Industrial Control System Installation, Operation and Maintenance Manual Table of Contents Installation............................ 3 Plumbing Inlet and Outlet Piping Drain Line Piping
More informationLaboratory Flowmeters
Laboratory Flowmeters Wide selection of flow ranges measure air from 0.02 ml/min to 675 LPM or water from 0.0002 ml/min to 20 LPM High-accuracy correlated flowmeters ±2% of reading! Excellent chemical
More informationWorkhorse-15 Oxygen Generator
11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse-15 Oxygen Generator Model No. 5719, 5727, 5735 for Domestic and International Units Part number 1432 Revision
More informationModel CS-1 Directional, Single Tone Urban/Inter-City Rail Air Horn
Model CS-1 Directional, Urban/Inter-City Rail Ideal for urban/inter-city rail applications, horn can withstand harsh environmental conditions and high speed train vibrations. Single tone 311 Hz fundamental
More informationINSERT FITTINGS INSERT FITTINGS
Insert Tee Insert x Female Tee Insert Elbow Insert x Male Elbow Insert Coupling Insert x Male Adapter Insert x Female Adapter Insert Plug POLY and NYLON FITTINGS For use with Poly Tubing Fitting 1/2 3/4
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationTechcon Systems TS1258 Pressure Pot
Techcon Systems TS1258 Pressure Pot User Guide TABLE OF CONTENT 1. SAFETY. 3 1.1 Intended Use 3 1.2 Safety Precaution 3 2. CERTIFICATE OF COMFORMANCE 4 3. FEATURES. 5 4. SPECIFICATIONS 5 5. INSTALLATION
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS CBW SERIES RESIDENTIAL BACKWASH FILTER SYSTEMS MODELS: CBW1001 CBW1501 CBW2001 Installer, please leave with homeowner. Homeowner, retain for future reference. INSTR2805
More informationTECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY
Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationTECHNICAL ACCESSORIES
A.R.I. VALVES S-050P AIR PLASTIC RELEASE 16 BAR Automatic Component A.R.I patent, Rolling Seal Mechanism: Dramatically reduces the possibility of obstruction by debris. Discharges high air flow rates upto
More informationINSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN
INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN Important: Read all instructions and refer to local codes prior to installation. l Local soil conditions may require more gravel for drainage. l
More informationDESIGN AND PRE - INSTALLATION INFORMATION
DESIGN AND PRE - INSTALLATION INFORMATION Installation of valves should be in accordance with The Water Supply (Water Fittings) Regulations 1999 and BS6700:1997 Para. 2.2.4 KP Type Valves offer a flexible
More informationACCESSORIES FOR LANCASTER PUMPS & WATER SYSTEMS INDEX
PAGE 1 ACCESSORIES FOR LANCASTER PUMPS & WATER SYSTEMS INDEX ADAPTERS PAGE OFFSET CASING ADAPTER 2 PITLESS ADAPTER 2 ROPE ADAPTER 4 VENTURI MALE ADAPTER 2 AIR VALUME CONTROL AIR VALVES 2 CABLE SUBMERSIBLE
More informationStorage Systems and Accessories
Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single
More informationHalsey Taylor Owners Manual STOP!
Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY
More informationTECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13
Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationBS2000 MOTOR ELECTRONICS, INC. PROTECTION INSTRUCTION MANUAL. (407) Phone: Website:
BS2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Revision Date: 6-23-14 RECOMMENDED REPLACEMENT
More informationscrew fittings - nickel plated brass series SC
screw fittings - nickel plated brass series SC SC SCC SC SC SC SC SC SCC SC SC SC SCC SC SC SC2C SC2 SC2 SC SC3 SC3 SC0 SC design screw fitting with swivel nut connection 1/"...1/2" optionally cylindrical
More informationDataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified
DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument
More informationPrestige Water Equipment Ltd.
The Prestige range of water softeners complements the range of water pre-treatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationQuality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed
Quality Plastic Pipe Fittings Technical Data Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed Effective April 1, 2002 PIPE DIMENSIONS IPS-IRON PIPE SIZE Minimum
More informationPiece Weight. List Price. Basket Strainer-Plastic. Wash Tray Plug. TIP TOE Tub Drain. Shower Drain Grids
PLUMBING SPECIALTIES PS_1018 EFFECTIVE OCTOBER 1, 2018 (SUPERCEDES PS_0918) The issuance of this price list is not an offer to sell the goods listed herein at the prices stated. Bath Coupling Elbow 123-096
More informationFIRE PROTECTION PRODUCTS
AGF Manufacturing Inc. FIRE PROTECTION PRODUCTS PRODUCT CATALOG CAT-AGF_V002 1/15 Reliability, Versatility, Code Compatibility AGF Product Catalog Table of Contents COLLECTa ndrain Auxiliary Drains Model
More informationCULLIGAN CSM SERIES WATER SOFTENER
Cat. No. 01016370 Rev. F 02/24/14 DCO # 014223 Installation, Operating and Service Instructions CULLIGAN CSM SERIES WATER SOFTENER 2014 Culligan International Com pa ny Printed in USA Attention Culligan
More informationRK-IR Sample Draw Aspirator Adapter Operator s Manual
30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More informationUSE AND MAINTENANCE MANUAL V260
USE AND MAINTENANCE MANUAL V260 S.A.T.I.A. srl Società Italiana apparecchiatura trattamento acqua MAN0034 BOZZA Pag. 1 di 21 DOCUMENT REVISION REVISION NOTE DATE MAN0034 DRAFT S.A.T.I.A. srl Società Italiana
More informationUser's Manual. MixRite TF 10. Edition 05.08
User's Manual MixRite TF 10 Edition 05.08 1 Tefen MixRite TF 10 fertilizer and chemicals Injector Congratulations on your purchase of one of Tefen s high quality products. To get the best results from
More informationMODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL
MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL Prepared by CR Manning Edited by SC Woidtke Rev August 22, 2011 PRESSURIZED WATER VESSEL OPERATING MANUAL 1. Background 1.1 The Pressurized
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More information36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS
36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING
More informationWelker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct
More informationThe ultimate in water softening
Calming troubled waters Metered Water Softener Specification MODEL: CALSOFT M The ultimate in water softening Due to Calmag s commitment to new product development the photographs contained within these
More informationDual Solenoid Gas Valve Installation
Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationProduct Catalogue. February We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping
Product Catalogue February 2019 PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping We mean progress. Table of contents Table of contents 1 Uponor Design Services
More informationINDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES
INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts
More informationTECHNICAL DATA. Q= Cv S
Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationTECHNICAL DATA. Dry 132a. October 1, 2008
October 1, 2008 Dry 132a 1. Description Viking High Pressure (HP) Dry Systems utilize a Viking Model E or Model F Deluge Valve to control the water supply to system piping equipped with closed sprinklers.
More informationHalsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!
Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED
More informationMunicipal Boost w/pre-treatment Monitoring System K-A-MCB-PRE
Operation Manual Municipal Boost w/pre-treatment Monitoring System K-A-MCB-PRE 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2
More informationOperation and Maintenance Manual for
Operation and Maintenance Manual for KFZST KF Series Twin Softener Systems Catalog # Serial # USFilter 10 Technology Drive Lowell, Massachusetts 01851 Tel: (800) 875-7873 Fax: (978) 441-6025 Email: Lowell_TechSupport@USFilter.com
More informationSanitizer Parts. Sanitizer Parts. Replacement Parts for Sanitizers
Sanitizer Parts for Sanitizers 513 Automatic Feeder Model 300, 302, 300-19, 300-29 Order No.: R171016 R171026 Model No.: 300 302 Description: AUTOMATIC FEEDER SPA HOT TUB FEEDER 1 1 R172008W 3 in. threaded
More informationINSTRUCTION MANUAL. Automatic Water Softener System. Model: PSE-08. Xsential Water Filtration Systems
INSTRUCTION MANUAL Automatic Water Softener System Model: PSE-08 Xsential Water Filtration Systems 78 Daly Street Ascot Western Australia 6104 Ph: 1300 366 295 Fax: (08) 9277 2266 www.xsential.com.au Welcome
More informationAvenger Model 33M Installation & Operation Instructions
Avenger Model 33M Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737 Phone:
More informationBGC258 Series BASOTROL Gas Valve
Installation Instructions BGC258 Issue Date September 6, 2017 BGC258 Series BASOTROL Gas Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing
More informationKRO AUGUST Prepared for: WashTec Australia 1, 33 Maddox Street Alexandria NSW 2015 Sydney, Australia
KRO - 3000 AUGUST 2006 Prepared for: WashTec Australia 1, 33 Maddox Street Alexandria NSW 2015 Sydney, Australia Prepared by: Chatoyer Holdings Pty. Ltd. ABN: 99 080 301 515 www.chatoyer.com.au BRISBANE
More informationTECHNICAL DATA. Q = C v P S
Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction
More informationLivewell/Baitwell Pumps. Livewell/Aerator
Livewell/Baitwell Pumps 03 Livewell/Baitwell Pumps Livewell/Aerator 049 050 03 Livewell / Baitwell Pumps selection GUIDE Livewell / Baitwell Pumps Tournament Series Bronze Base Fitting Discharge Outlet
More informationBARRICADE 286 AIRLINE FILTERS
BARRICADE 286 AIRLINE FILTERS PART NUMBERS AND SCHEMATICS GUIDE Company Profile Since 1944, Marco has developed a strong tradition of providing innovative and reliable products and services to the surface
More informationTECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
More information