OIL PRESSURE SENSORS
|
|
- Jeffrey Lewis
- 5 years ago
- Views:
Transcription
1 OIL PRESSURE SENSORS
2 OE Ref1(VDO) OIL PRESSURE SENSOR Ref2(DT) Ref3(TT) Ref4 DESCRIPTION PICTURE Key Tech. SPECIFICTION (outer diameter of (Thread) hexagonal (Terminal) (Circuit) nut) C 4, MERCE NG MERCE O/TOURISMO US OIL PRESSURE SENSOR 0 5bar/0.25 bar 24 M18* C MERCE LK/LN2,MK,NG MERCE O US MERCE K,T2/LN1,UNIMOG OIL PRESSURE SENSOR 05bar 19 M14* C 4, MERCE MK,NG,O US,SK OIL PRESSURE SENSOR 05bar 24 M C 4, MERCE O US VOLVO 440K/460L/480E OIL PRESSURE SENSOR 05bar; 0.25bar 19 M14*1.5
3 OE Ref1(VDO) Ref2(DT) Ref3(TT) Ref4 DESCRIPTION PICTURE Key Tech. (outer diameter of hexagonal nut) SPECIFICTION (Thread) (Terminal) (Circuit) /7 VOLVO 440K/460L/480E OIL PRESSURE SENSOR 05bar M14* C 1,21135 SCNI OIL PRESSURE SENSOR 010bar M14* C 1,21145 SCNI 3,4 OIL PRESSURE SENSOR 010bar M14* C (61/2,61/3) 1,21147 SCNI 3,4 010bar M14*1.5
4 OIL PRESSURE SENSORS, TEMPERTURE SENSORS ND TEMPERTURE SWITCHES
5 VDO OE C 3 M10 x 1 con. Short 19, K 3 M10 x 1 con. Short 19, C 5 19, C 5 23,8 15, C 10 M10 x 1 con. Short 19, K 10 M10 x 1 con. Short 19, C 10 19, K 10 19, C K 10 OIL PRESSURE SENSORS M12 x ,5 12 M12 x , C 10 23,8 15, C 5 M18 x , K 5 M18 x , C 5 M14 x , K 5 M14 x , C 10 M14 x , C 10 M14 x ,5 12 D C 5 19,5 11 E C 10 19,5 11 D Technical Data Overpressure safety: 30 bar, 40 bar or 50 bar max. (short periods only for 2 sec) Operating temperature: 25 C to +100 C (up to +120 C for 1 hour max. at threaded connector) Resistance range: Dimensions &Circuit Diagram&Type of C 5 M18 x , C 10 R 1/8 DIN ,5 11 D C 5 M14 x , C 5 M12 x , C 3 M12 x ,5 12 F C 10 M12 x , C 10 19,5 10 F C 3 M12 x ,5 12 G C 10 R 1/8 Din ,5 11
6 VDO OE C M10 x 1 con. Short 19, K M10 x 1 con. Short 19, C ± 0.15 M10 x 1 con. Short 19, K ± 0.15 M10 x 1 con. Short 19, C ± 0.15 M10 x 1 con. Short 19, C ± 0.15 M12 x , C ± 0.15 M12 x , C ± 0.15 M10 x 1 con. Short 19, K ± 0.15 M10 x 1 con. Short 19, C ± , C ± 0.15 M10 x 1 con. Short 19, C ± , C 10 0,9 ± 0.15 M10 x 1 con. Short 19, C ± 0.15 M10 x 1 con. Short 19, C ± 0.15 M12 x , C 80 PSI 8 ± 2.0 PSI 23,8 15, C ± 0.15 M12 x , C 80 PSI 6 ± 2.0 PSI 19, C ± 0.2 M18 x , C ± 0.15 M14 x , K ± 0.15 M14 x , C ± 0.15 M14 x , C ± 0.15 M10 x 1 con. Short 19, K ± 0.15 M14 x , C ± 0.15 M14 x , C ± 0.1 M14 x ,5 12 F C ± 0.15 M18 x , K ± 0.15 M18 x , C ± 0.2 M18 x , C ± 0.15 M10 x 1 con. Short 19, C 10 2 ± 0.3 M10 x 1 con. Short 19, C ± , K ± , C /0.1 19, C ± 0.15 M18 x , C 10 1 ± 0.15 M14 x , K ± 0.15 R 1/8 DIN ,5 11 Technical Data Overpressure safety: 30 bar or 50 bar max. (short periods only for 2 sec) Warning contact: Closes as pressure falls Switching capacity of warning contact: 5 W max. noninductive Operating temperature: 25 C to +100 C (up to +120 C for 1 hour max. at threaded connector) Dimensions &Circuit Diagram&Type of
7 VDO OE C ± 0.2 M18 x , C ± 0.15 M14 x ,5 12 F C ± 0.2 M18 x , C 10 5 ± 0,3 M14 x ,5 12 H C 10 1 ± 0,15 M14 x ,5 12 E C / ,5 11 C C ± 0.15 M14 x , C , C ± 0.2 M10 x 1,0 18,5 10 J C ± 0.3 M16 x ,5 12 D C ± 0.15 M10 x 1,0 18,5 10 L C ± ,5 11 J C ± 0.2 M18 x ,5 12 D C ± 0.15 M18 x , C ± ,5 10 L C ± 0.5 M10 x 1 con. Short 19,5 11 J C 7 10 ± 2 PSI 19,5 10 N C ± 0.15 M18 x ± ±0.5 L C ± 0.15 M14 x ,5 12 N C ± 0.15 M18 x ,5 12 N C ± 0.15 M14 x ,5 12 O C 10 1 ± 0.15 M14 x ,5 12 O C 10 5 ± 0.3 M12 x 1.5 con. Short 21,5 13 O ± 0.2 M14 x ,5 12 P C ± 0.3 M14 x ,5 12 P ± 0.2 M14 x ,5 12 P ± 0.3 M14 x ,5 12 P C ± 0.15 M18 x ,5 12 D Technical Data connector) Resistance range: Dimensions &Circuit Diagram&Type of
8 VDO OE C C C C C C C C C C C 2 19,5 11 M10 x 1 con. Short 19,5 11 M10 x 1 con. Short 19,5 11 M14 x , ,5 11 M18 x ,5 12 M12 x ,5 12 C M18 x , ,5 11 1/4 18 NPTF 23,8 15,3 19,5 11 C C 5 19,5 11 C C 10 M12 x , C 5 M18 x ,5 12 E C 5 M14 x ,5 12 E C 10 M16 x ,5 12 H C 7 19,5 10 H K 5 19,5 10 D C 5 n/a n/a Technical Data Overpressure safety: 30 bar or 50 bar max. (short periods only for 2 sec) Operating temperature: 25 C to +100 C (up to +120 C for 1 hour max. at threaded connector) Resistance range: Dimensions &Circuit Diagram&Type of
9 VDO OE C ± , C ± , C 80 PSI 10 ± 2.0 PSI 19,5 11 C C 10 1 ± 0.15 M14 x , C 10 5 ± 0.3 M14 x , C ± , C ± 0.3 M12 x ,5 12 D C ± 0.3 M18 x ,5 12 D C ± 0.15 M18 x ,5 12 D C ± 0.3 M18 x ,5 12 D Technical Data Overpressure safety: 30 bar or 50 bar max. (short periods only for 2 sec) Warning contact: Closes as pressure falls Switching capacity of warning contact: 5 W max. noninductive Operating temperature: 25 C to +100 C (up to +120 C for 1 hour max. at threaded connector) Resistance range: Dimensions &Circuit Diagram&Type of
10 VDO OE Technical Data K ± 5.3 M14 x N ± 5.3 M14 x N ± N ± N ± K ± N ± K ± 4.3 M18 x N ± 4.3 M18 x K ± 4.3 M14 x E N ± 4.3 M14 x E N ± 4.3 M16 x E N ± 4.3 taper seat D ,5 ± E N ± 4.3 M16 x D ± 5.3 M14 x D D ± 2.1 M10 x 1.5 6,9 22 C N ± 2.7 M14 x D ± 2.7 R 1/ D ± D D ± C ± 2.7 M16 x E D ± D D K TEMPERTURE SENSORS ± 2.7 M14 X 1.5 Thread length ± 2.7 M14 X 1.5 Thread length D ± D D ± 4.3 8,5 22 C D ± 5.3 M10 x 1,0 8,5 22 C D ± 2.7 8,2 22 C D ± 2.7 M10 X 1 con. short 8,2 22 C D ± 2.7 M10 x 1.5 6,9 22 C Version: Thermistor Temperature response time: 3 minutes minimum after switching on operating current Dimensions &Type of
11 VDO OE Technical Data K ± 2.7 M12 x 1.5 6,9 22 C D M16 x D M14 x K M14 x D M18 x D ± ± ±0.5 C K ± 5.3 M10 X 1 con. short without 10,5 C N ± 5.3 M10 X 1 con. short without 10,5 C D ± 2.5 without 10,5 C D ± 4.3 M14 x F C ± ± ± ±0.4 G C ± ± ± ±0.4 G C ± ± ± ±0.1 G D ± 9 8,2 22 C K ± 4.3 M14 x G N ± 4.3 M14 x G C ± 4.3 G 120 taper seat K ± G N ± G N ± G N ± G N ± 4.3 M18 x G N ± 2.7 M14 x G N ± G N ± 2.7 G 150 taper seat C ± 0.8 M14 x H ± 17.6 M14 x 1.5 7,5 29 H C ± 143 M14 x 1.5 8,5 29 H C ± 5.2 M14 x 1.5 8,5 29 H ± 19.5 M18 x ± ±0.6 H D M18 x ** C ** Dimensions &Type of
12 VDO OE Technical Data C ± 2.1 R3/8 (Din 2999 taper) 9 29 ±0.3 E C ± 3 10,9 29 G** C ± 3 taper seat C ± 3 10,9 29 G** C ± ± D ± ± 4.3 M14 x D ± ± D ± ± 4.3 M14 x D ± ± 4.3 M14 x D 120 ± ± 4.3 M16 x D 120 ± ± 4.3 M14 x D ± ± 4.3 M14 x D ± ± D ± ± D ± ± 4.3 M14 x D ± ± 4.3 M14 x D ± ± D ± ± 4.3 M14 x D ± ± 4.3 M14 x D ± ± 4.3 M14 x D ± ± E ± ± 4.3 5/8 18 UNF D ± ± 4.3 M14 x D ± ± D ± ± D ± ± D ± ± D ± ± D ± ± 2.7 M14 x D ± ± 2.7 M14 x C ± ± 2.7 M14 x D ± ± D ± ± 2.7 M14 x 1.5 G** * Depending on connection **For dualstation readings Version: Thermistor Temperature response time: 3 minutes minimum after switching on operating current Switching capacity: 1.2 W to 3 W noninductive reak point: 5 C max. below make point Contacting mode: Slowacting Type of contact: Switch closes as temperature rises Dimensions &Type of
13 VDO OE Technical Data D ± ± 2.7 M14 x D ± ± 2.7 M14 x D 150 ± ± 2.7 M14 x D ± ± 4.3 M14 x D ± ± 4.3 M14 x D ± ± 4.3 M14 x D ± ± 4.3 M14 x D ± ± D ± ± 4.3 M14 x C ± ± 2.7 M14 x D ± ± 1.5 M14 x C ± ± 2.2 M14 x 1.5 D Dimensions &Type of C M14 x 1.5 Version: Thermistor, 1pole Common Ground Temperature response time: 3 minutes minimum after switching on operating current Operating value: Instrument
14 VDO OE Technical Data Dimensions &Type of D ±102 M10 x 1.0 Version: Thermistor Operating temperature: 25 C to +125 C max. Temperature response time: 3 minutes minimum after switching on operating current C M14 x 1.5 Version: Thermistor, 1pole Common Ground Temperature response time: 3 minutes minimum after switching on operating current Operating value: C M14 x 1.5 Instrument
15 TEMPERTURE SWITCHES VDO Technical Data Dimensions & Type of D 90±3 SS 120 M10x E D 125±5 SS 155 M10x E D SS 180 M10x E D 96±3 SS E D 105±3 SS E D ±3 SS 150 M10x1 con.short 7 33 E D 120±3 SS D 90±3 SS 120 M14x D ±3 SS 160 M14x D 95±3 SS 120 M14x D 90±3 SS 120 M14x1.5 con.short D 60±3 SS 120 M14x1.5 con.short D 95±3 SS 150 M14x D 85±3 SS 120 M14x D 120±3 SS 130 M14x D 92±3 SS 120 M14x D 100±3 SS 160 M14x D 105±3 SS 120 M14x D 55±3 SS 120 M14x D 105±3 SS D 115±3 SS 130 M14x D 80±3 SS 120 M14x1.5 con.short D 97±3 SS 120 M14x D 40±3 SS 120 M14x D D 95±3 SS 120 M18x D 75±3 SS 120 M18x D 98±3 SS D 130±3 SS 150 M14x D 102±3 SS 150 M14x D 120±3 SS D 55±3 SS 120 M14x D 35±3 SS 120 M14x D 103±3 SS Switching capacity: 1.2 W to 3 W noninductive Type of contact: SS = Contact closes as temperature rises OS = Contact opens as temperature rises Contacting mode: Slowacting reak point: 5 C max. below make point
16 VDO Technical Data Dimensions & Type of D 102±3 SS 150 M14x D D 103±3 SS D 28 ± 3 SS 120 M14 x 1.5 9, C 126 ± 3 SS 150 M18 x D 120± 3.3 SS ± ± D 105 ± 3 SS H D 94 ± 3 SS 150 M14 x 1.5 9,7 29 D D 35 ± 3 SS 120 M14 x 1.5 9, E 25 ± 3 OS 120 M14 x D E 16 ± 3 OS 120 M14 x D VDO Technical Data Dimensions & Type of 44 X ** 64 ±3 60 ±3 M14 x X * 82 ±3 74 ±3 X * 86 ±3 81 ±3 X * 92 ±3 85 ±3 X * 96 ±3 92 ±3 X * 96 ±3 91 ±3 X * 96 ±3 92 ±3 X * 96 ±3 92 ±3 X * 100 ±3 95 ±3 X * 105 ±3 100 ±3 M18 x 1.5 M18 x 1.5 M18 x 1.5 M18 x 1.5 M14 x 1.5 M22 x 1.5 M18 x 1.5 M18 x 1.5 C 6 V to 12 V Switching capacity: 100/120 W Make point: Contact closes as temperature rises reak point: Contact opens as temperature falls 2blade connection: 6.3 x 0.8 DIN * Switching capacity 100 W ** Switching capacity 120 W
Hand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
More informationBW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface
ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US
More informationDPS-400 SERIES DPH-100 SERIES
745 Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES SERIES General terms and conditions... F- guide... P.699~ Related Information Glossary of terms... P.156~ General precautions... P.1566 PHOTO
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationPN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12
PN LINE PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN
More informationPILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R
PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is
More informationReferences, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3)
References, characteristics Electromechanical pressure switches For power circuits, type XMP. IP degree of protection Size (87 psi). Adjustable differential, for regulation between thresholds Switches
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationPressure switch and Thermostat CAS
Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to
More informationKDV HIGH ACCURACY GLASS TUBE ROTAMETER
KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design
More informationATM/GR. Electronic pressure switches CUSTOMER BENEFITS
Electronic pressure switches ATM/GR CUSTOMER BENEFITS Pressure sensor with integrated switching contacts Modular sensor structure (any process and electrical connections can be combined) Manual readjustment
More informationEx-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC
www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive
More informationSEALED CONNECTORS FOR THE LIMIT SWITCHES
SEALED CONNECTORS FOR THE LIMIT SWITCHES LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches. Type and appearance Materials Features Target market Applications
More informationPILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R
PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More informationBUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-
BUTTERFLY VALVES 1. General HyrdoWer is a globally recognized manufacturer of power unit accessories. They have become specialists in the design of Butterfly Valves and Hydraulic Compensators. The shut
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationTypes and approvals. Page 1/6. Data Sheet
Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description
More informationClimatic Independent Level Sensor LAR
1 Product Information LAR-361 LAR-761 Climatic Independent Level Sensor LAR Application / Specified usage Authorizations Hydrostatic level measurement in humid ambiance Special applicable for exterior
More informationXML Electromechanical Pressure Switches
Selection Guide Industrial Switches Type of installation ontrol circuits Applications Media controlled Type of operation Air, water, hydraulic oils, corrosive fluids, viscous products Fixed differential:
More informationP9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6
P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationInfrared Linescanners
Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories
More informationElectromechanical pressure switches
Presentation Electromechanical pressure switches OsiSense XM For power circuits, type XMP Presentation Pressure switches type XMP are switches for power circuits (direct switching), with an adjustable
More information2-jaw self-centering pneumatic parallel gripper (series SX)
SX 2-jaw self-centering pneumatic parallel gripper (series SX) Double acting (normally closed on request). High gripping force. Protection class: IP67. Double O-Ring sealing on the columns. Suitable for
More informationFixed Displacement Plug-In Motor A2FE
www.phphyds.com Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Sizes 28...355 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement plug-in
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationKDV HIGH ACCURACY GLASS TUBE ROTAMETER
KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design
More informationFITTING IDENTIFICATION AMERICANT THREAD TYPES APPENDIX ALFAGOMMA // APPENDIX. Dash numers. NPTF (National Pipe Tapered Fuel)
// FITTINGS GUIDelines FITTING IDENTIFICATION numers Most fluid piping system sizes are measured by dash numbers. These are universally used abbreviations for the size of component expressed as the numerator
More informationIntru-lok Flareless Bite Type Fittings
Intru-lok Flareless Bite Type Fittings 4300 atalog Flareless Bite Type Fittings Nuts, Ferrules, Inserts BIP Knurled Nut BI2 Nut BTI2 Nut and Ferrule TI2 Ferrule TIP Expander / Insert T23UI Insert HBI2
More informationDiaphragm pressure switches, 42 V
0166 Diaphragm pressure switches, 42 V Zinc-plated steel body With push-on terminals Overpressure safe to 300 bar *) 0166 Diaphragm pressure switches Adjustment range Thread Normally open (no) : Normally
More informationcompact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP
00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle
More informationPressure switch for gas and air
Pressure switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF GXX_A4
More informationPressure switch and Thermostat Type KPS
MAKING MODERN LIVING POSSIBLE Data sheet Pressure switch and Thermostat Type KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has
More informationQuick reference. Quick reference
Quick reference Quick reference Measurement methodology for frequently occurring hose fittings Hose size ight series Heavy series Fine thread Banjo French (pipe in inches) French ( pipe light) French (
More informationHow to specify a product. Process Sensors and Mechanical Instruments
How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationPressure Switch for gas and air GGAO-A4
Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes
More information// ADapters GUIDelines
// ADapters GUIDelines ADAPTER SELECTION Selection of an appropriate ALFAGOMMA adapter for a given application depends on the fluid system operating parameters listed below and the tube material and wall
More informationBourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type
Mechanical Pressure Measurement Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type 230.25 WIKA Datasheet 230.25 Applications Semiconductor and electronic industry, medical industry, gene
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationOrbital Motors Type OMP X and OMR X
Technical Information Orbital Motors Type OMP X and OMR X powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev January 218 Major revision. 21 February 217 First edition. 11 2
More informationEPRB-2 Pressure Transducer
Small size with amplified output Any liquid or gas media compatible with stainless steel Operating temperature up to 150 C (300 F) Variety of pressure ports Available as gage and absolute CE approved DESCRIPTION
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationIFP C175-* REMOTE CONTROL RELIEF VALVE
IFP C175-* REMOTE CONTROL RELIEF VLVE Low Pressure Differential Quiet Operation Easy to djust Handle Three Pressure Ranges vailable Panel Mount Design P T Model Pressure Range (PSI) Rated Flow (US GPM)
More informationOrbital Motors Type OMP, OMR and OMH. Technical Information
Orbital Motors Type OMP, OMR and OMH Technical Information OMP, OMR and OMH Contents Revision View Date Page Changed Revision Mar 26 Small updates B Jun 27 all Major revision with new lit-number (minus
More informationMechanical Pressure Switches for overpressure, vacuum pressure and differential pressure
Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure Switching range: -250 +100 mbar, 1 16 mbar to 16 63 bar Temperature: max. 70 C Material: Copper, brass, stainless
More informationClimatic Independent Level Sensor LAR
3 JAHRE GEWÄHRLEISTUNG 1 Product Information LAR-361 LAR-761 f o o d Climatic Independent Level Sensor LAR 3 3 Y R S W A R R A N T Y Application / Specified usage Authorizations Hydrostatic level measurement
More informationCFSW. Hinges with built-in safety multiple switch
CFSW. Hinges with built-in safety multiple switch ELESA Original design technical informations Material - Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black colour. Resistant to solvents,
More informationInductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm
Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More information(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)
This exhaust needle valve, which comes with silencer, controls the exhaust flow rate. The valve can be attached directly to a solenoid valve where a cylinder or like mechanism has no sufficient space around
More informationCFSW. Hinges with built-in safety multiple switch
CFSW. Hinges with built-in safety multiple switch ELESA Original design Elesa Standards Main dimensions Fitting Weight Code Description L B f ±0.2 f 1 ±0.2 H h 1 h 2 d 3 d 4 C [Nm]# g 426601 CFSW.110-6-2NO+2NC-C-A
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationPressure Switches Application Guideline
Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment
More informationOver-center valves type LHT with oscillation damping, zero leakage
Over-center valves type LHT with oscillation damping, zero leakage Flow rate Q max = 250 lpm Operation pressure p max = 450 bar See also: o Over-center valve type LHK acc. to D 7100 o Over-center valve
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationMANUAL KPS Pressure Control Valve
TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationPressure gauges EN Safety pressure gauges solid-front PBXSF100, PBXSF150 (1.20) Functional and constructive characteristics
Pressure gauges FT PBXSF 100-150-E-9.02 Safety pressure gauges solid-front PBXSF100, PBXSF150 (1.20) EN 837-1 These Solid-Front instruments are built in accordance with safety specifications of EN 837.1
More informationPILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R
PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure a secondary part of a hydraulic circuit. Pressure is mataed
More informationPneumatic service kit Model CPG-KITP
Calibration technology Pneumatic service kit Model CPG-KITP WIKA data sheet CT 93.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service industry
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationData sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782
Data sheet Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E2.02 520B0782 Survey Type KPS pressure switches 1. Standard pressure switches Range Further -1 0 10 20 30 40 50 60 bar P e Type
More informationAuxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998
Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal
More informationptfe and stainless steel hoses
ptfe and stainless steel hoses 3 table of contents Description P.004 Description of FX01 hoses P.004 Description of FX02 hoses P.004 Description of FX03 hoses P.005 Description of FX06 hoses P.005 DESCRIPTION
More informationDatasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code
Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code ENGLISH These quick connect versions allow rapid termination Miniature connector
More informationM iniature Amplified Pressure Sensors
M iniature Amplified Pressure Sensors ±0.3 psi to 100 psi Pressure Sensors Features 0 to ±0.3 to 0 to 30 psi Pressure Ranges Ratiometric 4V Output Temperature Compensated Calibrated Zero and Span General
More informationPressure switches and thermostats, type KPS
Description KPS units are pressure-controlled switches. The position of the contacts depends on the pressure in the inlet connection and the set scale value. In this series, special attention has been
More informationMechanical Pressure Switches for overpressure, vacuum pressure and differential pressure
Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure Switching range: -250 +100 mbar, 1 16 mbar to 16 63 bar Temperature: max. 70 C Material: Copper, brass, stainless
More informationSpin-On Filters SSF 24,25
Spin-On Filters SSF,5 Technical Specification Construction Die cast aluminium head Seals NBR (Buna-N ) Port connections Flow rate Working pressure Operating temperature By-pass valve Clogging indicators
More informationPressure Relief Valves. SPV, SPVF direct operated
Pressure Relief Valves SPV, SPVF direct operated Construction P Ø d 1 a T c 2 3 b 4 1 Housing 2 Sliding piston 3 Compression spring 4 Set screw Bleeding screw 6 Protective cap 6 Description The pressure
More informationSECTION 9 CLASSIC SERIES PUMPS
SECTION CLASSIC SERIES PUMPS 07 EDCO USA www.edcousa.net : CLASSIC PUMPS DUAL BASE CLASSIC PUMPS TRIPLE BASE CLASSIC PUMPS QUAD BASE CLASSIC PUMPS General Information : Classic Pumps: How To Order :4 Classic
More informationDifferential pressure switch / Lube oil protection control MP 54 and MP 55
Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors
More informationPressure switch and Thermostat KPS
Data sheet Pressure switch and Thermostat KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has been given to meeting demands for
More informationPRESSURE SEQUENCE VALVE TYPE UZK
PRESSURE SEQUENCE VALVE TYPE UZK Size 10, 20, 30 31,5 MPa up to 450 dm 3 /min WK 450 414 04. 2000r. Pressure sequence valves type UZK are used for switching a system or part of a system off when a set
More informationPVQ 13 A2 R SE 1 S 20 C-11 D
PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard
More informationProduct information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983
Product information Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69 Document ID: 29983 Contents Contents 1 Description of the measuring principle... 3 2 Type overview...
More information1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type
Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing
More informationTECHNICAL DATA BROCHURE - ZTR 428 & 429
TECHNICAL DATA BROCHURE - ZTR 428 & 429 DATE 8/89 (Rev.) MPORTANT -- READ OPERATOR S MANUAL BEFORE OPERATING OR MAKING ADJUSTMENTS. Deluxe Seat Adjustment Easy hand lever action allows forward and backward
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationRED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 271
RED DOT UNITS Controls Water & Air PAGE 271 AIR SWITCHES AND CYLINDERS 72R000 Normally Closed, Opens at 2 PSIG 1 8-27 NPTF Male AIR SENSING SWITCHES RD--447-0P 72R0070 Normally Open, Closes at 21 TO 29
More informationCONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES
I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical
More informationElectrically Operated Pressure-Relief Cartridge, Size 10
Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description
More informationRED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 343
RED DOT UNITS Controls Water & Air PAGE 343 AIR SWITCHES AND CYLINDERS 72R000 Normally Closed, Opens at 2 PSIG 1 8-27 NPTF Male AIR SENSING SWITCHES RD--447-0P 72R0070 Normally Open, Closes at 21 TO 29
More informationTECHNICAL DATA - CHASSIS 185
TECHNICAL DATA - CHASSIS 185 Frame Fork Shock absorber Suspension travel (990 Adventure) Suspension travel (990 Adventure R) Suspension travel (990 Adventure) Suspension travel (990 Adventure R) Brake
More informationEasy to operate. Wide space
With a force gauge and attachments, compression/tensile/pealing tests are possible up to 1000N/2500N. It provides consistent testing speed and direction, offering highly accurate test results. MX2-2500N
More information(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD
The polyurethane tube, featuring excellent flexiblity, helps compact piping requiring small bending radius. The useful cut marks at 500mm interval are printed on the tube. Model UD0425 UD0640 UD0860 UD1075
More informationOperating instruction for the quick-change tap holders type:
type: HF 20 HF 30 Date of edition: 15.07.2008 Stage of alteration: 4 Please keep this for future use! Contents: 1 Application range, safety instructions and technical data... 3 1.1 Application range,
More informationNorval Pressure regulator
Norval Pressure regulator NORVAL Classification and Field of Application The NORVAL is a downstream pressure regulator, self actuated, spring loaded for medium and low pressure applications. It is suitable
More informationTools & Installation. Tools & Installation Index
L Radius +0 59-2 32 60 +2 A B -0 32 C E F.09" ia. Weep Hole Tools & Installation MAXIMATOR offers manual Coning and Threading tools that are designed to prepare accurate tubing ends to accept the medium,
More informationVariable Area Flow Meters
PDF Published May, 04 Variable Area Flow Meters Chemline F Series Variable Area Flow Meters are ideal for plastic piping. They provide a combination of accurate visual flow rate measurement and clear flow
More informationBladder Accumulators High pressure
Bladder Accumulators High pressure 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas (nitrogen) is utilised in
More information24 AWG Nano M8 Single Ended and Double Ended Assemblies
24 AWG M8 Single Ended and Double Ended Abrasion Chemicals Flexing UL Listed CSA IP68 Rated RoHS Compliant 300 V Operating Temperature Range -30 C to 90 C Current Rating: 4 Amps Cord sets made with Trex-Onics
More informationAPG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400
Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400 C US The PT-400 offers high accuracy and reliability over a wide range of pressures. The small size, integrated electronics, wide operating
More informationCautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the
The Silencer, connected to the exhaust port of a device, suppresses the exhaust noise. The Silencer displays an excellent noise suppression effect. Three types are available for your selection. The element
More informationSafety Valves Safety Devices Pressure Reducing Valves Cartridge Program Directional, Sluice Valves PN 400 DN 6
SCHUPP HPPNEUMATICS www.hlhydraulik.de D57562 Herdorf Tel +49(0)274493240 Fax +49(0)2744932456 schrupp@hlhydraulik.de Traditional Valves Manual ShutOff and Check Valves Type PN 64 DN 5, 25 HAV 5, HAV 25
More informationDigitale manometers. TYPE: ETD-01, klasse 0.5. Specificaties HOOFDSTUK 6
Digitale manometers TYPE: ETD-0, klasse 0.5 KASTDIAMETER: 63 MM Bereiken: 0-.6 bar tot 0-250 bar Nauwkeurigheid: 0,5% Aansluiting: /4 BSP RVS 304 (EN837-) Drukeenheid: bar, mbar, PSI, mpa, mh 2 O Batterij:
More informationMULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE
SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous
More information