POLYMER TEST KIT (CLAPPER METHOD) OFI PART No

Size: px
Start display at page:

Download "POLYMER TEST KIT (CLAPPER METHOD) OFI PART No"

Transcription

1 OFI Testing Equipment Polymer Test Kit (Clapper Method) Part # Instructions Page 1 of 4 POLYMER TEST KIT (CLAPPER METHOD) OFI PART No This test determines the Partially Hydrolyzed Polyacrylamide (PHPA) concentration in mud filtrates. The test involves measurement of the rate of ammonia generation while the mud filtrate is heated in the presence of sodium hydroxide solution. The ammonia is removed from the reaction vessel with a slow air purge and detected with a Dräger Tube. The approximate concentration of PHPA is determined by measuring the time required for the Dräger Tube to turn blue. The procedure can be used to analyze all filtrates except those containing some types of lignosulfonates and acrylate filtration control additives. Size: 17.5 x 13 x 10.0 inches (44.5 x 33 x 25.4 cm) Weight: 23 lbs 10 oz (10.7 kg) Components: # Filter Paper, 3 1/2 inch. 100/pkg # Street Ell, 1/8 inch # Dräger Tube, Ammonia, 5/a, CH20501, 10/box # Brush, Graduate, 10 3/4 x 1 1/2 inch # Cylinder, Graduated, 50 ml x 1 ml, glass # Wash Bottle, 500 ml, Polyethylene # Syringe, 20 ml, plastic # Syringe, 60 ml, plastic # Thermometer, Metal, 8" stem, F # Stopwatch, Digital # Power Cable, 115 Volt # Receptacle, 115 Volt # Hot Plate, with Thermostat, 115 Volt, 325 Watt # Needle Valve, Male, # Flowmeter NA Cylinder, glass, without lip, 250 ml NA Beaker, stainless steel, 1200 ml NA Funnel, glass, 6 inch, long stem NA File, triangular, 5 inch NA Pump, Whisper 300, aquarium NA Tubing, Latex, 3/16" ID, foot NA NA Tubing, Plastic, 1/8" ID, foot Tubing, glass, 6 mm Reagent:

2 OFI Testing Equipment Polymer Test Kit (Clapper Method) Part # Instructions Page 2 of 4 # *Sodium Hydroxide sol'n, 5.0N (20%), 16 oz (UN1824) Procedure: NOTE: THE UNIT MUST BE CALIBRATED IN ORDER TO OBTAIN ACCURATE RESULTS! 1. Be sure the equipment is both clean and dry. 2. Obtain 10 cm 3 of mud filtrate using an API filter press. 3. Remove the reaction glass 250 ml cylinder located inside the beaker, from the kit. Fill the stainless steel beaker with approximately 800 cm 3 of water, and place on the hot plate. Heat the water to F. The temperature may be controlled with the hot plate thermostat and by the addition of water from the wash bottle. 4. Break both ends of the Dräger tube and insert (with the numbers increasing from bottom to top) in the tubing. Attach the outlet tubing from the glass 250 ml cylinder. (no. 3 in figure 1). 5. Fill a 50 cm 3 syringe with 40 cm 3 of 20% sodium hydroxide solution and inject into the glass reaction cylinder (no. 4 in figure 1). Add 10 cm 3 of mud into cylinder 4 and seal and attach the cylinder to the holder apparatus. Start the air pump and the timer. 6. Record the time required for the blue color to reach the line marked "70" on the Dräger tube. 7. Compare the time required for the blue color to reach the "70" mark with the times on the calibration chart. Report the concentration of available polymer as pounds per barrel of product. 8. To clean the gas train, remove the glass reaction cylinder and rinse well with water. The other cylinder may be attached directly to the air pump and flushed with air for several minutes. Both glass cylinders should be thoroughly dried before re-using.

3 OFI Testing Equipment Polymer Test Kit (Clapper Method) Part # Instructions Page 3 of 4 Calibration: The procedure is performed with an aqueous solution containing 0.50 lb/bbl of high molecular weight Partially Hydrolyzed Polyacrylamide (PHPA) polymer. The air flow should be adjusted, using the adjustment at the base of the flowmeter and the excess flow valve, so that the time required for the blue color to reach the "70" mark is 24 to 25 minutes. This will require a flow of approximately 100 cc/min. There is some batch-to-batch variations in the Dräger tubes, but one calibration should be sufficient for all Dräger tubes having scale lengths of 51 to 56 mm. The unit should be recalibrated for Dräger tubes having scale lengths less than 51 or greater than 56 mm. When it is possible, always use Dräger tubes from only one batch to obtain the best accuracy. Batch numbers for Dräger tubes are located on the outside of each box. All Dräger tubes have an expiration date stamped on the outside of the box and should be used prior to this date. Time to "70" mark (Minutes) Polyacrylamide Polymer PHPA Less than 11 Greater than 1 11 to ' 01" to 15' 59" to ' 01" to 21' 59" to Greater than 30 Less than 0.2

4 OFI Testing Equipment Polymer Test Kit (Clapper Method) Part # Instructions Page 4 of 4 1. Drager Tube 2. Air Pump 3. Glass Cylinder, 250 ml Moisture trap 4. Glass Cylinder, 250 ml Reaction cylinder 5. Beaker, stainless steel 6. Hot Plate 7. Flowmeter 8. & 9. Air flow adjustments 10. Needle Valve, male 11. Stopper, no 8 Figure 1: Proper Assembly Of The Clapper Polymer Analysis Kit

5

HTHP Filter Press for Ceramic Disks with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual

HTHP Filter Press for Ceramic Disks with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual HTHP Filter Press for Ceramic Disks with 175-mL, Double-Capped Test Cell and CO 2 Pressuring Assemblies #170-00-7: (115 V) #170-01-6: (230 V) Instruction Manual Updated 12/30/2014 Ver. 1.2 OFI Testing

More information

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 7/26/2011 Ver. 2.2 4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information

INSTRUCTIONS: CHEMICAL ANALYSIS OF ACTIVE SULFIDES IN OIL-BASED DRILLING FLUID

INSTRUCTIONS: CHEMICAL ANALYSIS OF ACTIVE SULFIDES IN OIL-BASED DRILLING FLUID OFI Testing Equipment Chemical Analysis of Active Sulfides Instructions Page 1 of 4 INSTRUCTIONS: CHEMICAL ANALYSIS OF ACTIVE SULFIDES IN OIL-BASED DRILLING FLUID DESCRIPTION: 1. The Garrett Gas Train

More information

Model: AT-1000 L.P.G. FREEZE VALVE

Model: AT-1000 L.P.G. FREEZE VALVE Model: AT-1000 P/N: 2156006200 3829 Forest Parkway Suite 500 Wheatfield, NY 14120-3763 Phone: 716-629-3802 Fax: 716-693-9162 solutions@viatran.com www.viatran.com 1 OPERATION AND MAINTENANCE INSTRUCTIONS

More information

Experiment 18 Properties of Gases

Experiment 18 Properties of Gases Experiment 18 Properties of Gases E18-1 E18-2 The Task In this experiment you will investigate some of the properties of gases, i.e. how gases flow, their phase changes and chemical reactivity. Skills

More information

Model: AT-1000 L.P.G. FREEZE VALVE

Model: AT-1000 L.P.G. FREEZE VALVE Model: AT-1000 P/N: 2156006200 3829 Forest Parkway Suite 500 Wheatfield, NY 14120-3763 Phone: 716-629-3802 Fax: 716-693-9162 solutions@viatran.com www.viatran.com 1 OPERATION AND MAINTENANCE INSTRUCTIONS

More information

Technical Bulletin AL-134

Technical Bulletin AL-134 Technical Bulletin AL-134 Handling Air-Sensitive Reagents The Aldrich Sure/Seal system Anhydrous solvents and air-sensitive reagents from Aldrich are packaged in our exclusive Sure/Seal bottles which provide

More information

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010 LUDLUM MODEL 239-1F FLOOR MONITOR Revised LUDLUM MEASUREMENTS, INC. 501 OAK ST., P.O. BOX 810 SWEETWATER, TX 79556 325/235-5494 FAX: 325/235-4672 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants

More information

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS! EXPERIMENT # 6 Name: PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS! 1. Calculate the height of a corresponding column of mercury (in mm) that is at

More information

Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES

Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES 1. SCOPE Designation: FM 5-565 1.1 This test method covers the laboratory determination of the water conductivity

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information

Chlorinator MODEL MK-I

Chlorinator MODEL MK-I Chlorinator MODEL MK-I The New model MK- I is semi automatic gas type. Vacuum operated Solution feed Chlorinator designed to provide a continues & measured quantity of gas while in operation. It is suitable

More information

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES Page 1 of 6 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES 1. SCOPE A. This test method covers the laboratory determination of the water conductivity of a compacted asphalt

More information

Technical Process Bulletin

Technical Process Bulletin Technical Process Bulletin RIDOLINE 53 Alkaline Immersion Cleaner 1. Introduction: Technical Process Bulletin No. 234242 This Revision: 23-11-1990 RIDOLINE 53 is a powdered, silicated, alkaline immersion

More information

LABORATORY TECHNIQUES. Pouring Liquids

LABORATORY TECHNIQUES. Pouring Liquids LABORATORY TECHNIQUES Working in the chemistry laboratory you will be handling potentially dangerous substances and performing unfamiliar tasks. This section provides you with a guide to the safe laboratory

More information

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES Page 1 of 7 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES 1. SCOPE A. This test method covers the laboratory determination of the water conductivity of a compacted asphalt

More information

METHOD OF TEST FOR THEORETICAL MAXIMUM RELATIVE DENSITY OF BITUMINOUS PAVING MIXTURES LS-264 R27 ASTM D2041/D2041M

METHOD OF TEST FOR THEORETICAL MAXIMUM RELATIVE DENSITY OF BITUMINOUS PAVING MIXTURES LS-264 R27 ASTM D2041/D2041M 3. APPARATUS 3.1 BEAKERS OR VESSELS: Stainless steel vessel, 4000 ml capacity, no spout... 3.2 BALANCE: 4000 g capacity with an accuracy of ± 0.1 g... 3.3 RIFFLE SPLITTER: For splitting hot mix samples.

More information

Enzyme Activity Lab. Wear safety goggles when handling hydrogen peroxide.

Enzyme Activity Lab. Wear safety goggles when handling hydrogen peroxide. Enzyme Activity Lab This laboratory involves the use of an enzyme that will react with hydrogen peroxide. The enzyme is catalase and hydrogen peroxide (H2O2) is the substrate. The reaction is as follows:

More information

Exploring the Properties of Gases

Exploring the Properties of Gases Computer 30 The purpose of this investigation is to conduct a series of experiments, each of which illustrates a different gas law. You will be given a list of equipment and materials and some general

More information

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR SAND EQUIVALENT

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR SAND EQUIVALENT State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR SAND EQUIVALENT SCOPE This test method is intended to determine the proportion of detrimental fines (dust or clay size

More information

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 260-2595 RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL REVISION DATE: August 2018 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify NovaLynx

More information

Garrett Gas Train Instruction Manual

Garrett Gas Train Instruction Manual Garrett Gas Train Instruction Manual Part No. 552010001EA Rev. C TABLE OF CONTENTS SECTION PAGE NO. 1 Introduction...1 2 Safety Considerations...3 3 Procedure for Gas Train Analysis (Sulfides - Water

More information

Franklin Regional School District SCIENCE SENIOR HIGH Bid #17 Vendor Specifications

Franklin Regional School District SCIENCE SENIOR HIGH Bid #17 Vendor Specifications SCIENCE SENIOR HIGH Bid #17 Quotation number: Company: Address: Telephone: Email: Date: Authorized Name Authorized signature: Page 1 of 12 CHEMISTRY 0001 01 FLINT LIGHTER #AP8346 18.00 PKG6 0001 02 LIGHTER

More information

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual BioAerosol Nebulizing Generator Operation and Maintenance User Manual INTRODUCTION The BANG or BioAerosol Nebulizing Generator is a unique nebulizer for the generation of aqueous aerosols at a low air

More information

Figure. Experimental set up of catalyst, reactants and product syringes.

Figure. Experimental set up of catalyst, reactants and product syringes. Construction and Use of the Gas Reaction Catalyst Tube** As shown in the figures, the experimental apparatus consists of a 60 ml syringe containing the gaseous reactants connected to a gas phase catalyst

More information

COMBINED SCIENCE 0653/6 CO-ORDINATED SCIENCES 0654/6

COMBINED SCIENCE 0653/6 CO-ORDINATED SCIENCES 0654/6 Centre Number Candidate Number Candidate Name International General Certificate of Secondary Education UNIVERSITY OF CAMBRIDGE LOCAL EXAMINATIONS SYNDICATE COMBINED SCIENCE 0653/6 CO-ORDINATED SCIENCES

More information

Model VR6 System. Installation, Operation & Maintenance

Model VR6 System. Installation, Operation & Maintenance Model VR6 System Installation, Operation & Maintenance General: All Archer Instruments chlorination systems are carefully designed and tested for years of safe, accurate field service. All Archer Instruments

More information

Boyle s Law VC 09. Experiment 9: Gas Laws. Abstract

Boyle s Law VC 09. Experiment 9: Gas Laws. Abstract Experiment 9: Gas Laws VC 09 Abstract In this laboratory activity, you will experimentally confirm Boyle s Law, determine absolute zero from Gay-Lussac's Law, and determine the molecular weight of acetone,

More information

The Decomposition of Hydrogen Peroxide

The Decomposition of Hydrogen Peroxide The Decomposition of Hydrogen Peroxide Calculator 12 The decomposition of hydrogen peroxide in aqueous solution proceeds very slowly. A bottle of 3% hydrogen peroxide sitting on a grocery store shelf is

More information

Exploring the Properties of Gases

Exploring the Properties of Gases Exploring the Properties of Gases LabQuest 30 The purpose of this investigation is to conduct a series of experiments, each of which illustrates a different gas law. You will be given a list of equipment

More information

The Safe Use of Pyrophoric Substances

The Safe Use of Pyrophoric Substances The Safe Use of Pyrophoric Substances INTRODUCTION In light of a fatality of a researcher earlier this year at UCLA, The University of Queensland has released a guideline for The Safe Use of Pyrophoric

More information

METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1.1 Applicability. This procedure is applicable for

METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1.1 Applicability. This procedure is applicable for METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1. INTRODUCTION 1.1 Applicability. This procedure is applicable for determining the input of volatile organic

More information

Instruction Manual Updated 5/26/2009 Ver. 2.0

Instruction Manual Updated 5/26/2009 Ver. 2.0 Bench-Mount Filter Press With Air Cylinder Part No. 140-35 Instruction Manual Updated 5/26/2009 Ver. 2.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300

More information

Gas Laws: Boyle s and Amonton s Laws MCTC Chemistry v.9.17

Gas Laws: Boyle s and Amonton s Laws MCTC Chemistry v.9.17 Gas Laws: Boyle s and Amonton s Laws MCTC Chemistry v.9.17 Objective: The purpose of this experiment is confirm Boyle's and Amontons' Laws in the laboratory. Prelab Questions: Read through this lab handout

More information

VISCOMETER, OFI, 8-SPEED, MODEL 800 PART No

VISCOMETER, OFI, 8-SPEED, MODEL 800 PART No OFI Testing Equipment Viscometer, 8 Speed, Model 800 Instructions Part # 130-10 Page 1 of 4 VISCOMETER, OFI, 8-SPEED, MODEL 800 PART No. 130-10 The model 800 eight speed electronic viscometer is designed

More information

Standard Test Procedures Manual

Standard Test Procedures Manual STP 206-5 Standard Test Procedures Manual Section: 1. SCOPE 1.1. Description of Test This method describes the procedure for determining the sand equivalent of granular material. 1.2. Application of Test

More information

CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature

CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature Thermostats CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature Description The CTC 1000 series room thermostats are for use in HVAC systems for the control of pneumatic valves and

More information

ExamLearn.ie. The Air & Oxygen

ExamLearn.ie. The Air & Oxygen ExamLearn.ie The Air & Oxygen The Air & Oxygen The air is a mixture of gases, which forms a blanket around the earth. Another name for the air is the atmosphere. *To investigate the percentage of oxygen

More information

Garrett Gas Train. Part No Instruction Manual. Updated 5/10/16 Ver. 4.0

Garrett Gas Train. Part No Instruction Manual. Updated 5/10/16 Ver. 4.0 Garrett Gas Train Part No. 151-00 Instruction Manual Updated 5/10/16 Ver. 4.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300 Fax: 713.880.9886 www.ofite.com

More information

Zero Head Space Extractor. Catalogue No. YT HW. Operation and Maintenance Manual

Zero Head Space Extractor. Catalogue No. YT HW. Operation and Maintenance Manual Catalogue No. YT30 090 HW Operation and Maintenance Manual ABOUT THE ZERO HEAD SPACE EXTRACTOR The Millipore Zero Head Space Extractor (ZHE) meets the U.S. EPA'S Toxicity Characteristics Leaching Procedure

More information

Generating Calibration Gas Standards

Generating Calibration Gas Standards Technical Note 1001 Metronics Inc. Generating Calibration Gas Standards with Dynacal Permeation Devices Permeation devices provide an excellent method of producing known gas concentrations in the PPM and

More information

mass of container full of air = g mass of container with extra air = g volume of air released = cm 3

mass of container full of air = g mass of container with extra air = g volume of air released = cm 3 1992 Q32 The air pressure inside the passenger cabin of an airliner is 9 x 10 4 Pa when the airliner is at its cruising height. The pressure of the outside atmosphere at this height is 4 x 10 4 Pa. Calculate

More information

Determination of R: The Gas-Law Constant

Determination of R: The Gas-Law Constant Determination of R: The Gas-Law Constant PURPOSE: EXPERIMENT 9 To gain a feeling for how well real gases obey the ideal-gas law and to determine the ideal-gas-law constant R. APPARATUS AND CHEMICALS: KClO

More information

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE GENERAL INFORMATION This family of dissolved oxygen electrodes is of the steam sterilizable polarographic type, designed to be interchangeable with NBS

More information

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high) Exploring the Properties of Gases Computer 30 The purpose of this investigation is to conduct a series of experiments, each of which illustrates a different gas law. You will be given a list of equipment

More information

K32230 DEW-POINT APPARATUS

K32230 DEW-POINT APPARATUS Installation, Operating and Maintenance Instructions K32230 DEW-POINT APPARATUS APPLICATIONS This manual has been prepared to assist in the preparation, use and care of the equipment. It is 1595 Sycamore

More information

Inspection and Approval of Asphalt Mix Design Laboratories

Inspection and Approval of Asphalt Mix Design Laboratories Supplemental Technical Specification for Inspection and Approval of Asphalt Mix Design Laboratories SCDOT Designation: SC-M-405 (06/07) 1. SCOPE 1.1 This method covers the process for inspection and approval

More information

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS OFI Testing Equipment - Aging Cell Instructions Page 1 of 4 Instructions OFITE AGING CELLS The OFITE Aging Cell is a patented pressure vessel that enables samples to be subjected to temperatures higher

More information

Reinforce design of experiments theory Make individual factorial designs and conduct analysis on responses

Reinforce design of experiments theory Make individual factorial designs and conduct analysis on responses Design of Experiments Lab #2 Developed by: Mike Evangelista, Nathan Haden, Alex Jannini, Rowan University, Department of Chemical Engineering Edited by: C. Stewart Slater and Mariano Savelski, Rowan University,

More information

Inspection and Acceptance of Asphalt Mix Design Laboratories

Inspection and Acceptance of Asphalt Mix Design Laboratories Supplemental Technical Specification for Inspection and Acceptance of Asphalt Mix Design Laboratories SCDOT Designation: SC-M-405 (05/1/14) 1. SCOPE 1.1 This specification covers the process for inspection

More information

HI 2314 HI 2315 HI 23151

HI 2314 HI 2315 HI 23151 Instruction Manual HI 2314 HI 2315 HI 23151 Multi-Range Conductivity Meters for Laboratories www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction

More information

Read over Techniques #2, 4, 5, 6, and 9 in the Demonstrations of Nine Practical Lab Techniques booklet.

Read over Techniques #2, 4, 5, 6, and 9 in the Demonstrations of Nine Practical Lab Techniques booklet. Practical Assessment 1 includes: Technique #2 - Use of a Pipette Technique #4 Weighing Technique #5 Use of a Bottle-Top Dispenser Technique #6 Gravity Filtration Technique # 9 Rotary Evaporator Student

More information

Working correctly with gas

Working correctly with gas Working correctly with gas When working with a reactive gas in a cylinder, there is an inherent risk. Special care has to be taken to allow safe handling. This example is with HCl. 1) Fixing the gas bottle.

More information

Before you start sampling, be sure to read

Before you start sampling, be sure to read 6. DISSOLVED OXYGEN MONITORING: MONITORING: Using the Titration Method Before you start sampling, be sure to read the following pages to familiarize yourself with the equipment and the procedures that

More information

Aging Cell, OFITE Style. Included Items

Aging Cell, OFITE Style. Included Items DRILLING FLUIDS EQUIPMENT For over 30 years OFI Testing Equipment (OFITE) has provided instruments and reagents for testing drilling fluids, well cements, completion fluids, and wastewater. In addition

More information

QUIK-jet Micro-Injection System

QUIK-jet Micro-Injection System QUIK-jet Micro-Injection System Training Manual Revision Date: 11/12/07 Table of Contents Subject Headings Pages Introduction 3 Parts of the QUIK-jet Kit 4 QUIK-jet Assembly and Setup 5-6 3 Easy Steps

More information

Aerotest Breathing Air Systems

Aerotest Breathing Air Systems DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Aerotest Breathing Air Systems Since 1937, when we introduced our first detector tube, Draeger has been the world leader in the

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

Observations Possible Causes Recommended Actions. Turquoise color

Observations Possible Causes Recommended Actions. Turquoise color ABI PRISM 3700 Instrument-Hardware-Array View Troubleshooting Module Please contact technical support if you have any questions regarding the document. Text in blue indicates a link to another section

More information

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES. BULLETIN 20-7000 ROTAMETERS PURGE FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES. INTRODUCTION McCrometer purge rotameters are precision-made instruments designed to accurately

More information

HTHP Viscometer. Features DRILLING FLUIDS EQUIPMENT

HTHP Viscometer. Features DRILLING FLUIDS EQUIPMENT DRILLING FLUIDS EQUIPMENT For over 30 years OFI Testing Equipment (OFITE) has provided instruments and reagents for testing drilling fluids, well cements, completion fluids, and wastewater. In addition

More information

1. The Safe Use of Pyrophoric Reagents

1. The Safe Use of Pyrophoric Reagents Rubin s group laboratory operating procedure series 1. The Safe Use of Pyrophoric Reagents REVISION RECORD Rev.# Date By Description 1 August 17, 2009 Mitsuharu Suzuki Initial release APPROVED (Signature

More information

H.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9

H.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9 H.T.S.T. EQUIPMENT TEST PROCEDURES Field Reference Sequence of Testing Equipment testing should be conducted in the following sequence to minimize equipment run times. Pasteurizer Not Operating 3, 1, 4,

More information

Instruction Manual Updated 6/22/06 Ver. 2.0

Instruction Manual Updated 6/22/06 Ver. 2.0 Millipore Filter Tester Part No. 145-00-10 Instruction Manual Updated 6/22/06 Ver. 2.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300 Fax: 713.880.9886

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50 Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y OFFICE: (507) 843-4700 P.O. BOX 7079 Toll

More information

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement CH2250: Techniques in Laboratory Chemistry Outline Measuring Mass Measuring Volume Significant figures Mass Measurement Mass Measurement Measure mass not weight Mass is measured with a balance (a scale

More information

Basic & Controlled Atmosphere Glove Boxes

Basic & Controlled Atmosphere Glove Boxes I N T R O D U C T I O N Precise Basic and Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Precise Basic Glove Boxes are simple, economical

More information

Reliable. Accurate. Results.

Reliable. Accurate. Results. Reliable. Accurate. Results. Product Catalog Alfa Wassermann Diagnostic Technologies, LLC is a leading provider of clinical diagnostic instrumentation and reagents to the medical community, specializing

More information

Gas Laws: Boyle s and Amonton s Laws Minneapolis Community and Technical College v.9.08

Gas Laws: Boyle s and Amonton s Laws Minneapolis Community and Technical College v.9.08 Gas Laws: Boyle s and Amonton s Laws Minneapolis Community and Technical College v.9.08 I. Introduction The purpose of this experiment is to test the extent real gases (to the limits of our measurements)

More information

Pipette apparatus. Meet the difference. Manual. T E I

Pipette apparatus. Meet the difference. Manual. T E I Pipette apparatus Manual Meet the difference Eijkelkamp Soil & Water Nijverheidsstraat 30, 6987 EM Giesbeek, the Netherlands T +31 313 880 200 E info@eijkelkamp.com I www.eijkelkamp.com 2018-07 M-0816E

More information

AIR CONTENT OF FRESHLY MIXED CONCRETE BY THE PRESSURE METHOD (Kansas Test Method KT-18)

AIR CONTENT OF FRESHLY MIXED CONCRETE BY THE PRESSURE METHOD (Kansas Test Method KT-18) 5.9.18 AIR CONTENT OF FRESHLY MIXED CONCRETE BY THE PRESSURE METHOD (Kansas Test Method ) 1. SCOPE 1.1. This method of test covers the procedure for determining the air content of freshly mixed concrete

More information

CORESTA RECOMMENDED METHOD Nº 67

CORESTA RECOMMENDED METHOD Nº 67 CORESTA RECOMMENDED METHOD Nº 67 DETERMINATION OF WATER IN THE MAINSTREAM SMOKE OF CIGARS BY GAS CHROMATOGRAPHIC ANALYSIS (November 2005) 1. FIELD OF APPLICATION The method is applicable to the particulate

More information

Polarimeter tubes and accessories

Polarimeter tubes and accessories Polarimeter tubes and accessories Opto-electronic measuring device since 1864 Polarimeter tubes of SCHMIDT+HAENSCH are designed for different applications. All tubes meet the ICUMSArecommendations, class

More information

MS.RAJA ELGADY/PRESSURE PAPER 3

MS.RAJA ELGADY/PRESSURE PAPER 3 1- (a) A water tank has a rectangular base of dimensions 1.5m by 1.2m and contains 1440 kg of water. Calculate (i) the weight of the water, weight =...... [1] (ii) the pressure exerted by the water on

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.

More information

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax Operation Manual Carbon Filtration 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2 Theory of Operation... 2 1.3 System Illustration...

More information

Svensk läkemedelsstandard

Svensk läkemedelsstandard Svensk läkemedelsstandard 2018.2 Nitrogen Postadress/Postal address: P.O. Box 26, SE-751 03 Uppsala, SWEDEN Besöksadress/Visiting address: Dag Hammarskjölds väg 42, Uppsala Telefon/Phone: +46 (0)18 17

More information

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References User Guide Pall Laboratory Manifold For laboratory use. Not for use in a manner other than indicated. Introduction Application and Intended Use The membrane filtration (MF) technique is a method of analyzing

More information

Laboratory Flowmeters

Laboratory Flowmeters Laboratory Flowmeters Wide selection of flow ranges measure air from 0.02 ml/min to 675 LPM or water from 0.0002 ml/min to 20 LPM High-accuracy correlated flowmeters ±2% of reading! Excellent chemical

More information

Vapor Pressure of Liquids

Vapor Pressure of Liquids Vapor Pressure of Liquids In this experiment, you will investigate the relationship between the vapor pressure of a liquid and its temperature. When a liquid is added to the Erlenmeyer flask shown in Figure

More information

This standard is due for Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid.

This standard is due for Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid. Background Statement for SEMI Draft Document 5211 REVISION OF SEMI C3.58-0303 SPECIFICATION FOR OCTAFLUOROCYCLOBUTANE, C 4 F 8, ELECTRONIC GRADE IN CYLINDERS, 99.999% QUALITY Note: This background statement

More information

Tex-416-A, Air Content of Freshly-Mixed Concrete by the Pressure Method

Tex-416-A, Air Content of Freshly-Mixed Concrete by the Pressure Method by the Pressure Method Contents: Section 1 Overview...2 Section 2 Apparatus...3...5 Section 4 Calculations...12 Texas Department of Transportation 1 08/99 06/08 Section 1 Overview Effective dates: August

More information

6900 Maintenance Instruction System Flush

6900 Maintenance Instruction System Flush Equipment Required FA74005 Damper Drain Tube FA16005 Cover Removal Tool FA900005 Beaker 0.25 Litre FA900003 Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves Latex

More information

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM Valve Model No's: 1-741, 1-742, 1-743, 1-744 1-741 1-742 1-743 1-744 2001 CARNEGIE AVE, SANTA ANA CA 92705 (949) 417-5207 WWW.NEWPORTBRASS.COM

More information

PURDUE UNIVERSITY TEFLON CORE PCB THRU-HOLE PREPARATION FOR BLACK HOLE APPLICATION RF LAB. Professor in charge: William Chappell MSEE 289

PURDUE UNIVERSITY TEFLON CORE PCB THRU-HOLE PREPARATION FOR BLACK HOLE APPLICATION RF LAB. Professor in charge: William Chappell MSEE 289 RF LAB Professor in charge: William Chappell MSEE 289 AUTHOR: BOB SALISBURY DATE: 12/5/2007 12/6/2007 page 1 of 7 TABLE OF CONTENTS 1 SCOPE... 3 2 PURPOSE... 3 3 REFERENCE DOCUMENTS... 3 4 MATERIALS...

More information

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N) 1 APPLICABILITY Exhibit 4 Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N) Definitions common to all certification and test procedures

More information

Alfred ECMO Circuit Priming and Storage Guide

Alfred ECMO Circuit Priming and Storage Guide Alfred ECMO Circuit Priming and Storage Guide 1 March 2012 Check List Page 2. Assembly, Priming and Storage Page 3. Prepare ECMO trolley and Circuit immediately before use Page 6. Connection to Patient

More information

Technical Procedure for General Laboratory Equipment

Technical Procedure for General Laboratory Equipment Technical Procedure for General Laboratory Equipment 1.0 Purpose - This procedure specifies the required elements for the use of general laboratory equipment. 2.0 Scope - This procedure applies to all

More information

ASPHALT PLANT LEVEL 1

ASPHALT PLANT LEVEL 1 ASPHALT PLANT LEVEL 1 Module 6: Maximum Specific Gravity FM 1 T 209 FDOT Course Release: 10, Module 6 1 Specification Year: January 2015 The terms Gmm or Maximum Specific Gravity or Rice gravity are often

More information

Calcimeter Instruction Manual

Calcimeter Instruction Manual Hohner (UK - Canada - Texas) Calcimeter Instruction Manual The Hohner Calcimeter is based on industry standard versions, and is used to measure the calcium carbonate and magnesium carbonate in samples.

More information

Pump On Demand. Skimmer System

Pump On Demand. Skimmer System Pump On Demand Skimmer System POD (Pump on Demand) Skimmer System Application Out-of-the-box LNAPL recovery in 2-inch and larger-diameter wells. The POD Skimmer model TR-610 recovers light-end hydrocarbons

More information

General Chemistry I Percent Yield of Hydrogen Gas From Magnesium and HCl

General Chemistry I Percent Yield of Hydrogen Gas From Magnesium and HCl Introduction For chemical reactions involving gases, gas volume measurements provide a convenient means of determining stoichiometric relationships. A gaseous product is collected in a long, thin graduated

More information

Osmometers. Product Selection Guide. Wissenschaftliche Gerätebau Dr. Ing. Herbert Knauer GmbH Hegauer Weg Berlin

Osmometers. Product Selection Guide. Wissenschaftliche Gerätebau Dr. Ing. Herbert Knauer GmbH Hegauer Weg Berlin Osmometers Product Selection Guide Osmometer Semi-Micro Osmometer K-7400 The Semi-Micro Osmometer enables freezing point depression to be measured. Additionally, the total osmolality of physiological and

More information

711 DISSOLUTION. Portions of the present general chapter text that are national USP text, and therefore not part of the

711 DISSOLUTION. Portions of the present general chapter text that are national USP text, and therefore not part of the Change to read: 711 DISSOLUTION This general chapter is harmonized with the corresponding texts of the European Pharmacopoeia and/or the Japanese Pharmacopoeia. The texts of these pharmacopeias are therefore

More information

STANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )

STANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S ) Page 1 of 27 1. Scope This Standard Operating Procedure (SOP) applies to the staff and students using the Advanced Intravenous Training Arm in the Pharmacy Practice Resource Unit (PPRU) at the Pharmacy

More information

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

High Pressure Equipment Taper Seal Valves, Fittings and Tubing igh quipment Taper Seal Valves, ittings and Tubing 0,000 and,000 psi service igh quipment Company has developed the Taper Seal line of products to assure safe and easy plumbing through,000 psi. These needle

More information

EXPERIMENT 2. Laboratory Procedures INTRODUCTION

EXPERIMENT 2. Laboratory Procedures INTRODUCTION EXPERIMENT 2 Laboratory Procedures INTRODUCTION Begin each experiment by taking the necessary safety precautions. All materials that will not be used in the lab should be placed out of the laboratory working

More information

Measurements. Metric System

Measurements. Metric System Measurements Measurements are basic to any scientific pursuit. A measurement has both a magnitude (numeric value) and a unit. Metric units are used in the sciences. Metric System In science, the metric

More information

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS WIDDER TOOLS HPIC-10000-D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS Description: The WIDDER Hydrostatic Test Systems C Series is a portable, selfcontained, air driven hydrostatic

More information