POLYMER TEST KIT (CLAPPER METHOD) OFI PART No
|
|
- Blake Harrell
- 5 years ago
- Views:
Transcription
1 OFI Testing Equipment Polymer Test Kit (Clapper Method) Part # Instructions Page 1 of 4 POLYMER TEST KIT (CLAPPER METHOD) OFI PART No This test determines the Partially Hydrolyzed Polyacrylamide (PHPA) concentration in mud filtrates. The test involves measurement of the rate of ammonia generation while the mud filtrate is heated in the presence of sodium hydroxide solution. The ammonia is removed from the reaction vessel with a slow air purge and detected with a Dräger Tube. The approximate concentration of PHPA is determined by measuring the time required for the Dräger Tube to turn blue. The procedure can be used to analyze all filtrates except those containing some types of lignosulfonates and acrylate filtration control additives. Size: 17.5 x 13 x 10.0 inches (44.5 x 33 x 25.4 cm) Weight: 23 lbs 10 oz (10.7 kg) Components: # Filter Paper, 3 1/2 inch. 100/pkg # Street Ell, 1/8 inch # Dräger Tube, Ammonia, 5/a, CH20501, 10/box # Brush, Graduate, 10 3/4 x 1 1/2 inch # Cylinder, Graduated, 50 ml x 1 ml, glass # Wash Bottle, 500 ml, Polyethylene # Syringe, 20 ml, plastic # Syringe, 60 ml, plastic # Thermometer, Metal, 8" stem, F # Stopwatch, Digital # Power Cable, 115 Volt # Receptacle, 115 Volt # Hot Plate, with Thermostat, 115 Volt, 325 Watt # Needle Valve, Male, # Flowmeter NA Cylinder, glass, without lip, 250 ml NA Beaker, stainless steel, 1200 ml NA Funnel, glass, 6 inch, long stem NA File, triangular, 5 inch NA Pump, Whisper 300, aquarium NA Tubing, Latex, 3/16" ID, foot NA NA Tubing, Plastic, 1/8" ID, foot Tubing, glass, 6 mm Reagent:
2 OFI Testing Equipment Polymer Test Kit (Clapper Method) Part # Instructions Page 2 of 4 # *Sodium Hydroxide sol'n, 5.0N (20%), 16 oz (UN1824) Procedure: NOTE: THE UNIT MUST BE CALIBRATED IN ORDER TO OBTAIN ACCURATE RESULTS! 1. Be sure the equipment is both clean and dry. 2. Obtain 10 cm 3 of mud filtrate using an API filter press. 3. Remove the reaction glass 250 ml cylinder located inside the beaker, from the kit. Fill the stainless steel beaker with approximately 800 cm 3 of water, and place on the hot plate. Heat the water to F. The temperature may be controlled with the hot plate thermostat and by the addition of water from the wash bottle. 4. Break both ends of the Dräger tube and insert (with the numbers increasing from bottom to top) in the tubing. Attach the outlet tubing from the glass 250 ml cylinder. (no. 3 in figure 1). 5. Fill a 50 cm 3 syringe with 40 cm 3 of 20% sodium hydroxide solution and inject into the glass reaction cylinder (no. 4 in figure 1). Add 10 cm 3 of mud into cylinder 4 and seal and attach the cylinder to the holder apparatus. Start the air pump and the timer. 6. Record the time required for the blue color to reach the line marked "70" on the Dräger tube. 7. Compare the time required for the blue color to reach the "70" mark with the times on the calibration chart. Report the concentration of available polymer as pounds per barrel of product. 8. To clean the gas train, remove the glass reaction cylinder and rinse well with water. The other cylinder may be attached directly to the air pump and flushed with air for several minutes. Both glass cylinders should be thoroughly dried before re-using.
3 OFI Testing Equipment Polymer Test Kit (Clapper Method) Part # Instructions Page 3 of 4 Calibration: The procedure is performed with an aqueous solution containing 0.50 lb/bbl of high molecular weight Partially Hydrolyzed Polyacrylamide (PHPA) polymer. The air flow should be adjusted, using the adjustment at the base of the flowmeter and the excess flow valve, so that the time required for the blue color to reach the "70" mark is 24 to 25 minutes. This will require a flow of approximately 100 cc/min. There is some batch-to-batch variations in the Dräger tubes, but one calibration should be sufficient for all Dräger tubes having scale lengths of 51 to 56 mm. The unit should be recalibrated for Dräger tubes having scale lengths less than 51 or greater than 56 mm. When it is possible, always use Dräger tubes from only one batch to obtain the best accuracy. Batch numbers for Dräger tubes are located on the outside of each box. All Dräger tubes have an expiration date stamped on the outside of the box and should be used prior to this date. Time to "70" mark (Minutes) Polyacrylamide Polymer PHPA Less than 11 Greater than 1 11 to ' 01" to 15' 59" to ' 01" to 21' 59" to Greater than 30 Less than 0.2
4 OFI Testing Equipment Polymer Test Kit (Clapper Method) Part # Instructions Page 4 of 4 1. Drager Tube 2. Air Pump 3. Glass Cylinder, 250 ml Moisture trap 4. Glass Cylinder, 250 ml Reaction cylinder 5. Beaker, stainless steel 6. Hot Plate 7. Flowmeter 8. & 9. Air flow adjustments 10. Needle Valve, male 11. Stopper, no 8 Figure 1: Proper Assembly Of The Clapper Polymer Analysis Kit
5
HTHP Filter Press for Ceramic Disks with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual
HTHP Filter Press for Ceramic Disks with 175-mL, Double-Capped Test Cell and CO 2 Pressuring Assemblies #170-00-7: (115 V) #170-01-6: (230 V) Instruction Manual Updated 12/30/2014 Ver. 1.2 OFI Testing
More informationInstruction Manual Updated 7/26/2011 Ver. 2.2
4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:
More informationINSTRUCTIONS: CHEMICAL ANALYSIS OF ACTIVE SULFIDES IN OIL-BASED DRILLING FLUID
OFI Testing Equipment Chemical Analysis of Active Sulfides Instructions Page 1 of 4 INSTRUCTIONS: CHEMICAL ANALYSIS OF ACTIVE SULFIDES IN OIL-BASED DRILLING FLUID DESCRIPTION: 1. The Garrett Gas Train
More informationModel: AT-1000 L.P.G. FREEZE VALVE
Model: AT-1000 P/N: 2156006200 3829 Forest Parkway Suite 500 Wheatfield, NY 14120-3763 Phone: 716-629-3802 Fax: 716-693-9162 solutions@viatran.com www.viatran.com 1 OPERATION AND MAINTENANCE INSTRUCTIONS
More informationExperiment 18 Properties of Gases
Experiment 18 Properties of Gases E18-1 E18-2 The Task In this experiment you will investigate some of the properties of gases, i.e. how gases flow, their phase changes and chemical reactivity. Skills
More informationModel: AT-1000 L.P.G. FREEZE VALVE
Model: AT-1000 P/N: 2156006200 3829 Forest Parkway Suite 500 Wheatfield, NY 14120-3763 Phone: 716-629-3802 Fax: 716-693-9162 solutions@viatran.com www.viatran.com 1 OPERATION AND MAINTENANCE INSTRUCTIONS
More informationTechnical Bulletin AL-134
Technical Bulletin AL-134 Handling Air-Sensitive Reagents The Aldrich Sure/Seal system Anhydrous solvents and air-sensitive reagents from Aldrich are packaged in our exclusive Sure/Seal bottles which provide
More informationLUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010
LUDLUM MODEL 239-1F FLOOR MONITOR Revised LUDLUM MEASUREMENTS, INC. 501 OAK ST., P.O. BOX 810 SWEETWATER, TX 79556 325/235-5494 FAX: 325/235-4672 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants
More informationPRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!
EXPERIMENT # 6 Name: PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS! 1. Calculate the height of a corresponding column of mercury (in mm) that is at
More informationFlorida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES
Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES 1. SCOPE Designation: FM 5-565 1.1 This test method covers the laboratory determination of the water conductivity
More informationTECHNICAL DATA CAUTION
Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.
More informationChlorinator MODEL MK-I
Chlorinator MODEL MK-I The New model MK- I is semi automatic gas type. Vacuum operated Solution feed Chlorinator designed to provide a continues & measured quantity of gas while in operation. It is suitable
More informationOHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES
Page 1 of 6 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES 1. SCOPE A. This test method covers the laboratory determination of the water conductivity of a compacted asphalt
More informationTechnical Process Bulletin
Technical Process Bulletin RIDOLINE 53 Alkaline Immersion Cleaner 1. Introduction: Technical Process Bulletin No. 234242 This Revision: 23-11-1990 RIDOLINE 53 is a powdered, silicated, alkaline immersion
More informationLABORATORY TECHNIQUES. Pouring Liquids
LABORATORY TECHNIQUES Working in the chemistry laboratory you will be handling potentially dangerous substances and performing unfamiliar tasks. This section provides you with a guide to the safe laboratory
More informationOHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES
Page 1 of 7 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES 1. SCOPE A. This test method covers the laboratory determination of the water conductivity of a compacted asphalt
More informationMETHOD OF TEST FOR THEORETICAL MAXIMUM RELATIVE DENSITY OF BITUMINOUS PAVING MIXTURES LS-264 R27 ASTM D2041/D2041M
3. APPARATUS 3.1 BEAKERS OR VESSELS: Stainless steel vessel, 4000 ml capacity, no spout... 3.2 BALANCE: 4000 g capacity with an accuracy of ± 0.1 g... 3.3 RIFFLE SPLITTER: For splitting hot mix samples.
More informationEnzyme Activity Lab. Wear safety goggles when handling hydrogen peroxide.
Enzyme Activity Lab This laboratory involves the use of an enzyme that will react with hydrogen peroxide. The enzyme is catalase and hydrogen peroxide (H2O2) is the substrate. The reaction is as follows:
More informationExploring the Properties of Gases
Computer 30 The purpose of this investigation is to conduct a series of experiments, each of which illustrates a different gas law. You will be given a list of equipment and materials and some general
More informationState of Nevada Department of Transportation Materials Division METHOD OF TEST FOR SAND EQUIVALENT
State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR SAND EQUIVALENT SCOPE This test method is intended to determine the proportion of detrimental fines (dust or clay size
More informationNOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL
NOVALYNX CORPORATION MODEL 260-2595 RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL REVISION DATE: August 2018 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify NovaLynx
More informationGarrett Gas Train Instruction Manual
Garrett Gas Train Instruction Manual Part No. 552010001EA Rev. C TABLE OF CONTENTS SECTION PAGE NO. 1 Introduction...1 2 Safety Considerations...3 3 Procedure for Gas Train Analysis (Sulfides - Water
More informationFranklin Regional School District SCIENCE SENIOR HIGH Bid #17 Vendor Specifications
SCIENCE SENIOR HIGH Bid #17 Quotation number: Company: Address: Telephone: Email: Date: Authorized Name Authorized signature: Page 1 of 12 CHEMISTRY 0001 01 FLINT LIGHTER #AP8346 18.00 PKG6 0001 02 LIGHTER
More informationBioAerosol Nebulizing Generator. Operation and Maintenance User Manual
BioAerosol Nebulizing Generator Operation and Maintenance User Manual INTRODUCTION The BANG or BioAerosol Nebulizing Generator is a unique nebulizer for the generation of aqueous aerosols at a low air
More informationFigure. Experimental set up of catalyst, reactants and product syringes.
Construction and Use of the Gas Reaction Catalyst Tube** As shown in the figures, the experimental apparatus consists of a 60 ml syringe containing the gaseous reactants connected to a gas phase catalyst
More informationCOMBINED SCIENCE 0653/6 CO-ORDINATED SCIENCES 0654/6
Centre Number Candidate Number Candidate Name International General Certificate of Secondary Education UNIVERSITY OF CAMBRIDGE LOCAL EXAMINATIONS SYNDICATE COMBINED SCIENCE 0653/6 CO-ORDINATED SCIENCES
More informationModel VR6 System. Installation, Operation & Maintenance
Model VR6 System Installation, Operation & Maintenance General: All Archer Instruments chlorination systems are carefully designed and tested for years of safe, accurate field service. All Archer Instruments
More informationBoyle s Law VC 09. Experiment 9: Gas Laws. Abstract
Experiment 9: Gas Laws VC 09 Abstract In this laboratory activity, you will experimentally confirm Boyle s Law, determine absolute zero from Gay-Lussac's Law, and determine the molecular weight of acetone,
More informationThe Decomposition of Hydrogen Peroxide
The Decomposition of Hydrogen Peroxide Calculator 12 The decomposition of hydrogen peroxide in aqueous solution proceeds very slowly. A bottle of 3% hydrogen peroxide sitting on a grocery store shelf is
More informationExploring the Properties of Gases
Exploring the Properties of Gases LabQuest 30 The purpose of this investigation is to conduct a series of experiments, each of which illustrates a different gas law. You will be given a list of equipment
More informationThe Safe Use of Pyrophoric Substances
The Safe Use of Pyrophoric Substances INTRODUCTION In light of a fatality of a researcher earlier this year at UCLA, The University of Queensland has released a guideline for The Safe Use of Pyrophoric
More informationMETHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1.1 Applicability. This procedure is applicable for
METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1. INTRODUCTION 1.1 Applicability. This procedure is applicable for determining the input of volatile organic
More informationInstruction Manual Updated 5/26/2009 Ver. 2.0
Bench-Mount Filter Press With Air Cylinder Part No. 140-35 Instruction Manual Updated 5/26/2009 Ver. 2.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300
More informationGas Laws: Boyle s and Amonton s Laws MCTC Chemistry v.9.17
Gas Laws: Boyle s and Amonton s Laws MCTC Chemistry v.9.17 Objective: The purpose of this experiment is confirm Boyle's and Amontons' Laws in the laboratory. Prelab Questions: Read through this lab handout
More informationVISCOMETER, OFI, 8-SPEED, MODEL 800 PART No
OFI Testing Equipment Viscometer, 8 Speed, Model 800 Instructions Part # 130-10 Page 1 of 4 VISCOMETER, OFI, 8-SPEED, MODEL 800 PART No. 130-10 The model 800 eight speed electronic viscometer is designed
More informationStandard Test Procedures Manual
STP 206-5 Standard Test Procedures Manual Section: 1. SCOPE 1.1. Description of Test This method describes the procedure for determining the sand equivalent of granular material. 1.2. Application of Test
More informationCTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature
Thermostats CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature Description The CTC 1000 series room thermostats are for use in HVAC systems for the control of pneumatic valves and
More informationExamLearn.ie. The Air & Oxygen
ExamLearn.ie The Air & Oxygen The Air & Oxygen The air is a mixture of gases, which forms a blanket around the earth. Another name for the air is the atmosphere. *To investigate the percentage of oxygen
More informationGarrett Gas Train. Part No Instruction Manual. Updated 5/10/16 Ver. 4.0
Garrett Gas Train Part No. 151-00 Instruction Manual Updated 5/10/16 Ver. 4.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300 Fax: 713.880.9886 www.ofite.com
More informationZero Head Space Extractor. Catalogue No. YT HW. Operation and Maintenance Manual
Catalogue No. YT30 090 HW Operation and Maintenance Manual ABOUT THE ZERO HEAD SPACE EXTRACTOR The Millipore Zero Head Space Extractor (ZHE) meets the U.S. EPA'S Toxicity Characteristics Leaching Procedure
More informationGenerating Calibration Gas Standards
Technical Note 1001 Metronics Inc. Generating Calibration Gas Standards with Dynacal Permeation Devices Permeation devices provide an excellent method of producing known gas concentrations in the PPM and
More informationmass of container full of air = g mass of container with extra air = g volume of air released = cm 3
1992 Q32 The air pressure inside the passenger cabin of an airliner is 9 x 10 4 Pa when the airliner is at its cruising height. The pressure of the outside atmosphere at this height is 4 x 10 4 Pa. Calculate
More informationDetermination of R: The Gas-Law Constant
Determination of R: The Gas-Law Constant PURPOSE: EXPERIMENT 9 To gain a feeling for how well real gases obey the ideal-gas law and to determine the ideal-gas-law constant R. APPARATUS AND CHEMICALS: KClO
More informationSTEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE
STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE GENERAL INFORMATION This family of dissolved oxygen electrodes is of the steam sterilizable polarographic type, designed to be interchangeable with NBS
More informationExploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)
Exploring the Properties of Gases Computer 30 The purpose of this investigation is to conduct a series of experiments, each of which illustrates a different gas law. You will be given a list of equipment
More informationK32230 DEW-POINT APPARATUS
Installation, Operating and Maintenance Instructions K32230 DEW-POINT APPARATUS APPLICATIONS This manual has been prepared to assist in the preparation, use and care of the equipment. It is 1595 Sycamore
More informationInspection and Approval of Asphalt Mix Design Laboratories
Supplemental Technical Specification for Inspection and Approval of Asphalt Mix Design Laboratories SCDOT Designation: SC-M-405 (06/07) 1. SCOPE 1.1 This method covers the process for inspection and approval
More informationOFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS
OFI Testing Equipment - Aging Cell Instructions Page 1 of 4 Instructions OFITE AGING CELLS The OFITE Aging Cell is a patented pressure vessel that enables samples to be subjected to temperatures higher
More informationReinforce design of experiments theory Make individual factorial designs and conduct analysis on responses
Design of Experiments Lab #2 Developed by: Mike Evangelista, Nathan Haden, Alex Jannini, Rowan University, Department of Chemical Engineering Edited by: C. Stewart Slater and Mariano Savelski, Rowan University,
More informationInspection and Acceptance of Asphalt Mix Design Laboratories
Supplemental Technical Specification for Inspection and Acceptance of Asphalt Mix Design Laboratories SCDOT Designation: SC-M-405 (05/1/14) 1. SCOPE 1.1 This specification covers the process for inspection
More informationHI 2314 HI 2315 HI 23151
Instruction Manual HI 2314 HI 2315 HI 23151 Multi-Range Conductivity Meters for Laboratories www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
More informationRead over Techniques #2, 4, 5, 6, and 9 in the Demonstrations of Nine Practical Lab Techniques booklet.
Practical Assessment 1 includes: Technique #2 - Use of a Pipette Technique #4 Weighing Technique #5 Use of a Bottle-Top Dispenser Technique #6 Gravity Filtration Technique # 9 Rotary Evaporator Student
More informationWorking correctly with gas
Working correctly with gas When working with a reactive gas in a cylinder, there is an inherent risk. Special care has to be taken to allow safe handling. This example is with HCl. 1) Fixing the gas bottle.
More informationBefore you start sampling, be sure to read
6. DISSOLVED OXYGEN MONITORING: MONITORING: Using the Titration Method Before you start sampling, be sure to read the following pages to familiarize yourself with the equipment and the procedures that
More informationAging Cell, OFITE Style. Included Items
DRILLING FLUIDS EQUIPMENT For over 30 years OFI Testing Equipment (OFITE) has provided instruments and reagents for testing drilling fluids, well cements, completion fluids, and wastewater. In addition
More informationQUIK-jet Micro-Injection System
QUIK-jet Micro-Injection System Training Manual Revision Date: 11/12/07 Table of Contents Subject Headings Pages Introduction 3 Parts of the QUIK-jet Kit 4 QUIK-jet Assembly and Setup 5-6 3 Easy Steps
More informationAerotest Breathing Air Systems
DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Aerotest Breathing Air Systems Since 1937, when we introduced our first detector tube, Draeger has been the world leader in the
More informationColumbus Instruments
0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011
More informationObservations Possible Causes Recommended Actions. Turquoise color
ABI PRISM 3700 Instrument-Hardware-Array View Troubleshooting Module Please contact technical support if you have any questions regarding the document. Text in blue indicates a link to another section
More informationBULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.
BULLETIN 20-7000 ROTAMETERS PURGE FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES. INTRODUCTION McCrometer purge rotameters are precision-made instruments designed to accurately
More informationHTHP Viscometer. Features DRILLING FLUIDS EQUIPMENT
DRILLING FLUIDS EQUIPMENT For over 30 years OFI Testing Equipment (OFITE) has provided instruments and reagents for testing drilling fluids, well cements, completion fluids, and wastewater. In addition
More information1. The Safe Use of Pyrophoric Reagents
Rubin s group laboratory operating procedure series 1. The Safe Use of Pyrophoric Reagents REVISION RECORD Rev.# Date By Description 1 August 17, 2009 Mitsuharu Suzuki Initial release APPROVED (Signature
More informationH.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9
H.T.S.T. EQUIPMENT TEST PROCEDURES Field Reference Sequence of Testing Equipment testing should be conducted in the following sequence to minimize equipment run times. Pasteurizer Not Operating 3, 1, 4,
More informationInstruction Manual Updated 6/22/06 Ver. 2.0
Millipore Filter Tester Part No. 145-00-10 Instruction Manual Updated 6/22/06 Ver. 2.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300 Fax: 713.880.9886
More informationINSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y
INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50 Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y OFFICE: (507) 843-4700 P.O. BOX 7079 Toll
More informationCH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement
CH2250: Techniques in Laboratory Chemistry Outline Measuring Mass Measuring Volume Significant figures Mass Measurement Mass Measurement Measure mass not weight Mass is measured with a balance (a scale
More informationBasic & Controlled Atmosphere Glove Boxes
I N T R O D U C T I O N Precise Basic and Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Precise Basic Glove Boxes are simple, economical
More informationReliable. Accurate. Results.
Reliable. Accurate. Results. Product Catalog Alfa Wassermann Diagnostic Technologies, LLC is a leading provider of clinical diagnostic instrumentation and reagents to the medical community, specializing
More informationGas Laws: Boyle s and Amonton s Laws Minneapolis Community and Technical College v.9.08
Gas Laws: Boyle s and Amonton s Laws Minneapolis Community and Technical College v.9.08 I. Introduction The purpose of this experiment is to test the extent real gases (to the limits of our measurements)
More informationPipette apparatus. Meet the difference. Manual. T E I
Pipette apparatus Manual Meet the difference Eijkelkamp Soil & Water Nijverheidsstraat 30, 6987 EM Giesbeek, the Netherlands T +31 313 880 200 E info@eijkelkamp.com I www.eijkelkamp.com 2018-07 M-0816E
More informationAIR CONTENT OF FRESHLY MIXED CONCRETE BY THE PRESSURE METHOD (Kansas Test Method KT-18)
5.9.18 AIR CONTENT OF FRESHLY MIXED CONCRETE BY THE PRESSURE METHOD (Kansas Test Method ) 1. SCOPE 1.1. This method of test covers the procedure for determining the air content of freshly mixed concrete
More informationCORESTA RECOMMENDED METHOD Nº 67
CORESTA RECOMMENDED METHOD Nº 67 DETERMINATION OF WATER IN THE MAINSTREAM SMOKE OF CIGARS BY GAS CHROMATOGRAPHIC ANALYSIS (November 2005) 1. FIELD OF APPLICATION The method is applicable to the particulate
More informationPolarimeter tubes and accessories
Polarimeter tubes and accessories Opto-electronic measuring device since 1864 Polarimeter tubes of SCHMIDT+HAENSCH are designed for different applications. All tubes meet the ICUMSArecommendations, class
More informationMS.RAJA ELGADY/PRESSURE PAPER 3
1- (a) A water tank has a rectangular base of dimensions 1.5m by 1.2m and contains 1440 kg of water. Calculate (i) the weight of the water, weight =...... [1] (ii) the pressure exerted by the water on
More informationDescription Advanced Features Typical Applications
Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied
More informationBlue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION
Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.
More informationOperation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax
Operation Manual Carbon Filtration 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2 Theory of Operation... 2 1.3 System Illustration...
More informationSvensk läkemedelsstandard
Svensk läkemedelsstandard 2018.2 Nitrogen Postadress/Postal address: P.O. Box 26, SE-751 03 Uppsala, SWEDEN Besöksadress/Visiting address: Dag Hammarskjölds väg 42, Uppsala Telefon/Phone: +46 (0)18 17
More informationUser Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References
User Guide Pall Laboratory Manifold For laboratory use. Not for use in a manner other than indicated. Introduction Application and Intended Use The membrane filtration (MF) technique is a method of analyzing
More informationLaboratory Flowmeters
Laboratory Flowmeters Wide selection of flow ranges measure air from 0.02 ml/min to 675 LPM or water from 0.0002 ml/min to 20 LPM High-accuracy correlated flowmeters ±2% of reading! Excellent chemical
More informationVapor Pressure of Liquids
Vapor Pressure of Liquids In this experiment, you will investigate the relationship between the vapor pressure of a liquid and its temperature. When a liquid is added to the Erlenmeyer flask shown in Figure
More informationThis standard is due for Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid.
Background Statement for SEMI Draft Document 5211 REVISION OF SEMI C3.58-0303 SPECIFICATION FOR OCTAFLUOROCYCLOBUTANE, C 4 F 8, ELECTRONIC GRADE IN CYLINDERS, 99.999% QUALITY Note: This background statement
More informationTex-416-A, Air Content of Freshly-Mixed Concrete by the Pressure Method
by the Pressure Method Contents: Section 1 Overview...2 Section 2 Apparatus...3...5 Section 4 Calculations...12 Texas Department of Transportation 1 08/99 06/08 Section 1 Overview Effective dates: August
More information6900 Maintenance Instruction System Flush
Equipment Required FA74005 Damper Drain Tube FA16005 Cover Removal Tool FA900005 Beaker 0.25 Litre FA900003 Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves Latex
More informationINSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM
INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM Valve Model No's: 1-741, 1-742, 1-743, 1-744 1-741 1-742 1-743 1-744 2001 CARNEGIE AVE, SANTA ANA CA 92705 (949) 417-5207 WWW.NEWPORTBRASS.COM
More informationPURDUE UNIVERSITY TEFLON CORE PCB THRU-HOLE PREPARATION FOR BLACK HOLE APPLICATION RF LAB. Professor in charge: William Chappell MSEE 289
RF LAB Professor in charge: William Chappell MSEE 289 AUTHOR: BOB SALISBURY DATE: 12/5/2007 12/6/2007 page 1 of 7 TABLE OF CONTENTS 1 SCOPE... 3 2 PURPOSE... 3 3 REFERENCE DOCUMENTS... 3 4 MATERIALS...
More informationExhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)
1 APPLICABILITY Exhibit 4 Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N) Definitions common to all certification and test procedures
More informationAlfred ECMO Circuit Priming and Storage Guide
Alfred ECMO Circuit Priming and Storage Guide 1 March 2012 Check List Page 2. Assembly, Priming and Storage Page 3. Prepare ECMO trolley and Circuit immediately before use Page 6. Connection to Patient
More informationTechnical Procedure for General Laboratory Equipment
Technical Procedure for General Laboratory Equipment 1.0 Purpose - This procedure specifies the required elements for the use of general laboratory equipment. 2.0 Scope - This procedure applies to all
More informationASPHALT PLANT LEVEL 1
ASPHALT PLANT LEVEL 1 Module 6: Maximum Specific Gravity FM 1 T 209 FDOT Course Release: 10, Module 6 1 Specification Year: January 2015 The terms Gmm or Maximum Specific Gravity or Rice gravity are often
More informationCalcimeter Instruction Manual
Hohner (UK - Canada - Texas) Calcimeter Instruction Manual The Hohner Calcimeter is based on industry standard versions, and is used to measure the calcium carbonate and magnesium carbonate in samples.
More informationPump On Demand. Skimmer System
Pump On Demand Skimmer System POD (Pump on Demand) Skimmer System Application Out-of-the-box LNAPL recovery in 2-inch and larger-diameter wells. The POD Skimmer model TR-610 recovers light-end hydrocarbons
More informationGeneral Chemistry I Percent Yield of Hydrogen Gas From Magnesium and HCl
Introduction For chemical reactions involving gases, gas volume measurements provide a convenient means of determining stoichiometric relationships. A gaseous product is collected in a long, thin graduated
More informationOsmometers. Product Selection Guide. Wissenschaftliche Gerätebau Dr. Ing. Herbert Knauer GmbH Hegauer Weg Berlin
Osmometers Product Selection Guide Osmometer Semi-Micro Osmometer K-7400 The Semi-Micro Osmometer enables freezing point depression to be measured. Additionally, the total osmolality of physiological and
More information711 DISSOLUTION. Portions of the present general chapter text that are national USP text, and therefore not part of the
Change to read: 711 DISSOLUTION This general chapter is harmonized with the corresponding texts of the European Pharmacopoeia and/or the Japanese Pharmacopoeia. The texts of these pharmacopeias are therefore
More informationSTANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )
Page 1 of 27 1. Scope This Standard Operating Procedure (SOP) applies to the staff and students using the Advanced Intravenous Training Arm in the Pharmacy Practice Resource Unit (PPRU) at the Pharmacy
More informationHigh Pressure Equipment Taper Seal Valves, Fittings and Tubing
igh quipment Taper Seal Valves, ittings and Tubing 0,000 and,000 psi service igh quipment Company has developed the Taper Seal line of products to assure safe and easy plumbing through,000 psi. These needle
More informationEXPERIMENT 2. Laboratory Procedures INTRODUCTION
EXPERIMENT 2 Laboratory Procedures INTRODUCTION Begin each experiment by taking the necessary safety precautions. All materials that will not be used in the lab should be placed out of the laboratory working
More informationMeasurements. Metric System
Measurements Measurements are basic to any scientific pursuit. A measurement has both a magnitude (numeric value) and a unit. Metric units are used in the sciences. Metric System In science, the metric
More informationHPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS
WIDDER TOOLS HPIC-10000-D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS Description: The WIDDER Hydrostatic Test Systems C Series is a portable, selfcontained, air driven hydrostatic
More information