Advanced Calibration Designs, Inc. goacd.com. Certified Calibration Gas Solutions

Size: px
Start display at page:

Download "Advanced Calibration Designs, Inc. goacd.com. Certified Calibration Gas Solutions"

Transcription

1 Advanced Calibration Designs, Inc. goacd.com Certified Calibration Gas Solutions

2

3 Table of Contents We Provide The Ultimate Calibration Gas Solution... 4 How to Buy... 4 CAL2000 Instrument & Accessories...5 CAL CAL 2000 Gas Options...6 CAL2000 Instrument & Accessories...7 Specifications...7 CAL 2000LT... 8 CAL 2000LT Gas Options...8 CAL2000LT Instrument & Accessories...9 Specifications...9 GENie Calibration Gas System GENie EC GENie EC Gas Options GENie EC Instrument & Accessories Specifications GENie O GENie O3 Ozone Gas Options...14 GENie O3 Instrument & Accessories Specifications GENie QC GENie QC-1 Gas Options...16 GENie QC-1 Instrument & Accessories Specifications CAL CAL 101 Gas Options...18 CAL 101 Instrument & Accessories...19 Specifications...19 MiniBump MiniBump Gas Options MiniBump Bump Tester & Accessories Specifications QC-50 Calibration Gas Bump Tester QC-50 and Bump Tester, Gas Options & Accessories Specifications QC-100 Calibration Gas Bump Tester QC-100 Bump Tester, Gas Options & Accessories Specifications Standard Warranty Gas Calibration Instruments... 24

4 We Provide The Ultimate Calibration Gas Solution ACD s certified calibration gas instruments and generating sources replace gas cylinders as an accurate, safe and easy to use solution. How to Buy Our full line of products and accessories are sold only by authorized distributors. Please visit or call to find a distributor in your area. 4

5 P/N PINCH HERE TO BREAK INNER AMPOULE POWER SELECT Press and Hold 3 seconds Tucson, Arizona, U.S.A. POWER SELECT Press and Hold 3 seconds Tucson, Arizona, U.S.A. Flow trim Empty Green / Cell Tucson Arizona USA Red / Battery Full Press and Hold 3 Seconds Advanced Calibration Designs Tucson, Arizona, USA Eject Outlet Advanced Calibration Designs. Tucson, AZ USA Outlet Advanced Calibration Designs. Tucson, AZ USA Vial Adjust Vial Insert Outlet Advanced Calibration Designs. Tucson, AZ USA Advanced Calibration Designs Tucson, Arizona, USA CAL2000 Instrument & Accessories Cal 2000 Cal 2000lt ACD Advanced Calibration Designs ACD Advanced Calibration Designs CAL 101 Status MiniBump Gas Generator EC O3 QC-100 QC-50 Gas Sources Demand Flow Capable Flow Rate Ammonia CAL 2000 CAL 2000LT CAL-101 MiniBump GENie EC GENie O3 GENie QC-1 QC-100 QC to 1 LPM 0.5 or 1 LPM* 0.5 or 1.0 LPM 0.5 LPM 0.2 to 1 LPM 1.0PPM PPM Variable N/A N/A or PPM Bump Test Bump Test Chlorine.05-1 or.5-50 PPM 1-25 PPM 1-25 PPM 1-25 PPM >5 PPM.05-5 or.5-50 PPM Chlorine Dioxide.5-5 PPM.5-5 PPM Hexane Bump Test Bump Test Hydrogen.05-1 or.5-50 PPM 1-25 PPM 1-25 PPM 1-25 PPM >25 PPM.5-50 or PPM Hydrogen Chloride Bump Test Bump Test Hydrogen Cyanide.05-1 or.5-50 PPM 1-25 PPM 1-25 PPM 1-25 PPM >10 PPM.05-5 or.5-50 PPM Hydrogen Sulfide.05-1 or.5-50 PPM 1-25 PPM 1-25 PPM 1-25 PPM >25 PPM.05-15or.5-50 PPM Nitrogen Dioxide.05 to 5 PPM Ozone.2-1 PPM Toluene Bump Test Bump Test Concentration Adjustable Cell Defined Cell Defined Cell Defined Adjustable Adjustable Adjustable N/A N/A Certifications Accuracy Available generating life Non-hazardous shipping CE,ATEX, CSA ± 5% or ± 10% 10, 50, 100 hours CE,ATEX, CSA ± 5% or ± 10% 10, 25 hours CE ± 20% 2 hours CE, ATEX, CSA ± 20% Up to 1000 tests or 5 hours N/A ± 5% or ± 10% 10, 50, 100 hours N/A ± 5% or ± 10% 500 hours N/A ± 10% 96 hours (8 hours / vial) N/A N/A 8 hours/vial N/A N/A 8 hours/vial 5

6 CAL 2000 CALIBRATION GAS INSTRUMENT The CAL 2000 provides unmatched versatility and accuracy in corrosive calibration gases. Field replaceable electrochemical generating sources provide a standard for accurately calibrating chlorine, chlorine dioxide, hydrogen, hydrogen cyanide, and hydrogen sulfide gas sensors. The CAL 2000 is microprocessor controlled and has an LCD display allowing field adjustable concentration and flow rate. The generating sources are interchangeable and field replaceable. Best of all, the CAL 2000 generating source provides up to 50 times as much calibration gas as a disposable cylinder at approximately the cost of just two cylinders. The CAL 2000 gas instrument has a built-in mass flow sensor that automatically compensates for altitude and temperature. Demand flow capable. CSA NRTL/C Exia T-6 approved intrinsically safe with CE mark and ATEX certification. NIST traceable certification. Adjustable PPM and flow rate. Automatic purge on shut down. Interchangeable calibration gases. Low power consumption. Alkaline battery powered. CAL 2000 Gas Options Gas PPM H2 Hydrogen ClO2 Chlorine Dioxide H2S Hydrogen Sulfide HCN Hydrogen Cyanide Cl2 Chlorine Concentration Adjustable Certifications CE, ATEX, CSA Accuracy ± 5% or ± 10% Available generating life 10, 50, 100 hrs. Non-hazardous shipping Interchangeable gases No shelf degradation Mass flow feedback 6

7 CAL2000 Instrument & Accessories What s Included? CAL 2000LT instrument with nylon carrying case, batteries hose and instruction manual. Sources are not included. A source is required to run the instrument and are interchangeable. Order sources as required from the list below. Instrument CAL 2000 Instrument Sources PPM Gas Size Hrs Cl2 (chlorine) Cl2 chlorine) Cl2 (chlorine) Double life Cl2 (chlorine) Micro Cl2 (chlorine) Micro Cl2 (chlorine) Micro double life ClO2 (chlorine dioxide) ClO2 (chlorine dioxide) ClO2 (chlorine dioxide) Double life H2 (hydrogen) H2 (hydrogen) H2 (hydrogen) Double life H2S (hydrogen sulfide) H2S (hydrogen sulfide) H2S (hydrogen sulfide) Double life H2S (hydrogen sulfide) Micro H2S (hydrogen sulfide) Micro H2S (hydrogen sulfide) Micro double life HCN (hydrogen cyanide) HCN (hydrogen cyanide) HCN hydrogen cyanide) Double life HCN (hydrogen cyanide) Micro HCN (hydrogen cyanide) Micro HCN (hydrogen cyanide) Micro double life 100 (PPM is variable with flow rate, output given at 0.5 LPM) Accessories Continuous operation adapter, 115VAC with US plug Hard body carrying case Replacement Parts Electrolyte, ClO2, 15 ml vial Electrolyte, ClO2, 15 ml vial, 5 pack Electrolyte, ClO2, 15 ml vial, 10 pack Electrolyte, ClO2, 15 ml vial, 25 pack Plunger feet fastener Outlet Fitting, body (1/8 NPT) quick connect Hose connector, insert (hose barb) quick connect Charcoal filter element Charcoal filter element, package of X Hose, with quick connect, Nylon carrying case Specifications Air Flow Rate (with internal pump) 0.2 to 1 (with internal pump) Sample draw rate 0.2 to 5 LPM (with pump disabled) Useful Source Life 10, 50 or 100 hours Warm-up time (to 90%) Approx. 5 minutes. L x W x H 8.50 x 4.25 x 3.00 (21.59 x 10.8 x 7.62 cm) Weight 3 lb. (1360 g) Operating Temperature 0 C to 50 C Relative Humidity (intermittent use) 0-100% Accuracy ±10% (±5% available) Repeatability ±5% Battery Power 4 alkaline C Battery Life 10 hours (at.5 LPM flow rate) H 2 ClO 2 H 2 S HCN Cl 2 7

8 CAL 2000LT CALIBRATION GAS INSTRUMENT The CAL 2000 LT is an economical alternative for calibration of corrosive gas detection equipment. The CAL 2000 LT is a microprocessor controlled calibration gas instrument with interchangeable and field replaceable gas generating sources. Each source provides up to 25 cylinders or 25 hours worth of gas at a fraction of the cost. A built-in mass flow sensor automatically compensates for altitude and temperature. The instrument is available in preset flow-rates of 0.5 or 1.0 LPM. Generating sources are rated at 10 or 25 hours and are available for chlorine, hydrogen, hydrogen cyanide and hydrogen sulfide. A gas concentration must be specified when ordering generating sources over a range of 1 to 25 PPM in whole PPM increments. To change gas type or concentration simply insert a different source into the instrument. CSA NRTL/C Exia T-6 approved intrinsically safe with CE mark and ATEX certification Non-hazardous shipping Built-in mass flow sensor Alkaline battery powered NIST traceable certificate Interchangeable calibration gases Multiple languages included CAL 2000LT Gas Options Gas PPM H2 Hydrogen H2S Hydrogen Sulfide HCN Hydrogen Cyanide Cl2 Chlorine Concentration Source defined Certifications CE, ATEX, CSA Accuracy ± 5% or ± 10% Available generating life 10, 25 hrs. Non-hazardous shipping Interchangeable gases No shelf degradation Mass flow feedback 8

9 H 2 CAL2000LT Instrument & Accessories What s Included? CAL 2000LT instrument with nylon carrying case, batteries hose and instruction manual. Sources are not included. A source is required to run the instrument and are interchangeable. Order sources as required from the list below. Instrument LT CAL 2000LT Instrument (*Specify flow rate when ordering) Sources Gas Hrs PPM LT Cl2 (chlorine) 10 Specify* LT Cl2 (chlorine) 25 Specify* LT H2 (hydrogen) 10 Specify* LT H2 (hydrogen) 25 Specify* LT H2S (hydrogen sulfide) 10 Specify* LT H2S (hydrogen sulfide) 25 Specify* LT HCN (hydrogen cyanide) 10 Specify* LT HCN (hydrogen cyanide) 25 Specify* *Specify PPM when ordering. Accessories Continuous operation adapter, 115VAC with US plug Hard body carrying case Replacement Parts Plunger feet fastener Outlet fitting, body (1/8 NPT) quick connect Hose connector, insert (hose barb) quick connect Charcoal filter element Charcoal filter element, package of X Hose, with quick connect, Nylon carrying case Specifications Air Flow Rate (with internal pump) 0.5 or 1 LPM flow rate must be specified when ordering) Useful Source Life 10 or 25 hours Warm-up time (to 90%) Approx. 5 minutes. L x W x H 8.50 x 4.25 x 3.00 (21.59 x 10.8 x 7.62 cm) Weight 3 lb. (1360 g) Operating Temperature 0 C to 50 C Relative Humidity (intermittent use) 0-100% Accuracy ±10% Repeatability ±5% Battery Power 4 alkaline C Battery Life 10 hours (at.5 LPM flow rate) H 2 S HCN Cl 2 9

10 GENie Calibration Gas System INTEGRATED AND EXPANDABLE The GENie Calibration Gas System is an integrated and expandable solution for hard to find calibration gas sources. Compact, hand-held, accurate, economical and rugged, this family of integrateable and expandable calibration gas instruments will generate a variety of gases from one modular instrument. As your calibration gas needs grow, so does the GENie, with integrated, expandable Source Modules that provide for a cost effective solution. 10

11 One GENie Base Unit plus any of the three interchangeable and expandable GENie Source Modules enable the instrument to produce the required certified calibration gas. GENie Base Unit calibration gas system Advanced Calibration Designs. Tucson, AZ USA Select Power Integrated microprocessor controlled feedback. Utilizes a mass flow controller for accurate flow rates across all instruments. Capable of future expansion beyond one gas type. Multiple languages included. NIST traceable. Eject Outlet EC Outlet O3 Outlet Vial Adjust Advanced Calibration Designs. Tucson, AZ USA Advanced Calibration Designs. Tucson, AZ USA Vial Insert Advanced Calibration Designs. Tucson, AZ USA GENie EC Source Module Adjustable gas concentrations created on demand. Interchangeable generating sources. Expandable concentrations and gases. Non-hazardous transport. Ideal for demand flow or diffusion applications. GENie O3 Source Module Most accurate source of O3 calibration gas on the Market. Selectable concentrations. Compact, portable hand-held design. Long life & simple to use. GENie QC-1 Source Module 96 hours of source gas included. Disposable gas vials have unlimited shelf life. Most accurate source of NH3 calibration gas on the market. Non-hazardous transport. 11

12 GENie EC CALIBRATION GAS INSTRUMENT The GENie EC is one of our most compact and user-friendly instruments. The GENie EC is our most accurate, diverse, compact and user-friendly instrument. Certified calibration gas sources provide the equivalent of up to 100 compressed gas cylinders. Interchangeable gases, adjustable concentrations, demand flow capable and the ability to provide the lowest most accurate concentrations in the industry make the GENie EC the smart choice for calibration professionals. Adjustable calibration gas concentrations created on demand. Interchangeable generating sources. Expandable concentrations and gases. Integrated microprocessor controlled feedback. Non-hazardous transport. Ideal for demand flow or diffusion applications. English, French, German, Portuguese and Spanish user interfaces are included. GENie EC Gas Options Gas PPM H2 Hydrogen ClO2 Chlorine Dioxide H2S Hydrogen Sulfide HCN Hydrogen Cyanide Cl2 Chlorine NO2 Nitrogen Dioxide.05 to 5.0 PPM Concentration Adjustable Accuracy ± 5% or ± 10% Available generating life 10, 50 or 100 hours / cell Non-hazardous shipping Interchangeable gases No shelf degradation Mass flow feedback 12

13 H 2 GENie EC Instrument & Accessories What s Included? GENie EC instrument with nylon carrying case, batteries hose and instruction manual. Sources are not included. A source is required to run the instrument and are interchangeable. Order sources as required from the list below. Instrument GENie EC Instrument Sources PPM Gas Size Hrs Cl2 (chlorine) Micro 10 hrs Cl2 (chlorine) Micro 50 hrs Cl2 (chlorine) Double life micro 100 hrs Cl2 (chlorine) 10 hrs Cl2 (chlorine) 50 hrs Cl2 (chlorine) Double life 100 hrs ClO2 (chlorine dioxide) 10 hrs ClO2 (chlorine dioxide) 50 hrs ClO2 (chlorine dioxide) Double life 100 hrs H2 (hydrogen) 10 hrs H2 (hydrogen) 50 hrs H2 (hydrogen) Double life 100 hrs H2 (hydrogen) High output 100 hrs H2S (hydrogen sulfide) Micro 10 hrs H2S (hydrogen sulfide) Micro 50 hrs H2S (hydrogen sulfide) Double life micro 100 hrs H2S (hydrogen sulfide) 10 hrs H2S (hydrogen sulfide) 50 hrs H2S (hydrogen sulfide) Double life 100 hrs HCN (hydrogen cyanide) Micro 10 hrs HCN (hydrogen cyanide) Micro 50 hrs HCN (hydrogen cyanide) Double life micro 100 hrs HCN (hydrogen cyanide) 10 hrs HCN (hydrogen cyanide) 50 hrs HCN (hydrogen cyanide) Double life 100 hrs NO2 (nitrogen dioxide) 50 hrs NO2 (nitrogen dioxide) 100 hrs Accessories Hard Body Case External Battery Extender (adds up to 13 hours of use) Continuous Operation Adapter (specify country) Replacement Parts Nylon Carrying Case Outlet Fitting Hose Connector Insert Magnetic Tip Screwdriver X 5 Foot Hose with Quick Connect External Charcoal Filter Assembly, GENie Series Specifications Air flow rate (with internal pump) 0.2 to 1 LPM Sample draw rate (with pump disabled) 0.1 to 1.2 LPM Source life 10, 50 or 100 hours / source Warm-up time (to 90%) Approx. 2 minutes L x W x H 5 W x 3.88 H x 3.13 D Weight 2 lb. (1360 g) Operating temperature 0 C to 50 C Relative humidity (intermittent use) 0-100% Accuracy ±10% Repeatability ± 5% Battery power 4 Alkaline AA Battery life 8 hours (at.5 LPM flow rate) ClO 2 H 2 S HCN Cl 2 NO 2 (PPM is variable with flow rate, output given at 0.5 LPM) GENie O3 Source Module (includes source) GENie QC-1 Source Module (includes source) 13

14 GENie O3 CALIBRATION GAS INSTRUMENT The GENie O3 portable calibration gas standard is small and lightweight for calibrating the most difficult to reach Ozone sensors. The GENie O3 will calibrate nearly any Ozone gas sensor or detection system on the market by utilizing its internal mass flow sensor and ultraviolet light source to provide accurate levels of Ozone gas to the end user. Ozone gas cannot be stored in cylinders and must be generated on site, therefore there are no calibration gas cylinders of ozone available on the market. The GENie O3 comes with an NIST certificate of calibration to +/- 10 %, providing exceptional accuracy as well as high precision. The unparalleled long life source in the instrument has an expected life of up to five hundred hours of use, allowing for extremely low cost calibrations over the life of the source. Most accurate source of ozone calibration gas on the market. Selectable concentrations. Integrated microprocessor controlled feedback. Compact, portable hand-held design. Long life. Simple to use. English, French, German, Portuguese and Spanish user interfaces are included. GENie O3 Ozone Gas Options Gas PPM O3 Ozone PPM Concentration Adjustable Accuracy ± 5% or ± 10% Available generating life Up to 500 hours Non-hazardous shipping No shelf degradation Mass flow feedback 14

15 O GENie O3 Instrument & Accessories What s Included? GENie Base Unit, GENie O3 Source Module, 1 hose, nylon carrying case, batteries and manual Instrument GENie O3 Instrument Sources GENie EC Module Source is not included. See GENie EC for source list GENie QC-1 Source Module (includes source) Accessories Continuous operation adapter, (specify country) plug External battery extender (does not include batteries) Hard body case Replacement Parts Hose connector, insert (hose barb) quick connect X Hose, with quick connect, Nylon carrying case, GENie Outlet fitting, body (1/8 NPT) quick connect Tool, ACD magnetic tip screwdriver External charcoal filter assembly, GENie series Specifications Air Flow Rate (with internal pump) Variable Useful Source Life Up to 500 hours Warm-up time (to 90%) Approx. 2 minutes. L x W x H 5.00 x 3.88 x 3.13 (12.7 x 9.85 x 7.95 cm) Weight 2 lb. (907 g) Operating Temperature 0 C to 50 C Relative Humidity (intermittent use) 0-100% Accuracy ±10% (±5% available) Repeatability ±5% Battery Power 4 alkaline aline AA Battery Life 6 hours 15

16 GENie QC-1 CALIBRATION GAS INSTRUMENT The GENie QC-1 ammonia calibration gas instrument - Compact, rugged and adjustable. The GENie QC-1 generates ammonia calibration gas by utilizing a sealed glass ampule that is broken for use, the GENie QC-1 is the perfect tool for anyone calibrating fixed or portable ammonia sensors. With user adjustable outputs, the GENie QC-1 can be set to a wide range of outputs allowing for calibration of nearly any ammonia detector on the market. The GENie QC-1 is compact and rugged allowing for use in the harshest environments. The easy to read LED display along with the instruments ergonomic design and nylon carrying case creates ease of use and portability. Once each ammonia vial has been broken for use, the GENie QC-1 will provide up to eight hours of continuous calibration gas before the vial is discarded, making the GENie QC-1 extremely cost effective. 96 hours of source gas included. Integrated microprocessor controlled feedback. Disposable gas vials have unlimited shelf life. Non-hazardous transport. The most accurate source of NH3 calibration gas on the market. Simple to use, NIST traceable. GENie QC-1 Gas Options Gas PPM NH3 Ammonia or Concentration Adjustable Accuracy ± 10% Available generating life 8 hours / vial Non-hazardous shipping Interchangeable gases No shelf degradation Mass flow feedback 16

17 NH GENie QC-1 Instrument & Accessories What s Included? GENie Base Unit, GENie QC-1 Source Module, 5 hose, nylon carrying case, batteries and manual. Instrument GENie QC-1 Instrument Sources GENie EC Module Source is not included. See GENie EC for source list GENie O3 Module Includes source (100 hrs.) Accessories NH3 (ammonia) QCV, 12 pack Continuous operation adapter, (specify country) plug External battery extender (does not include batteries) Hard body case Replacement Parts Hose connector, insert (hose barb) quick connect X Hose, with quick connect, Nylon carrying case, GENie Outlet fitting, body (1/8 NPT) quick connect Tool, ACD magnetic tip screwdriver External charcoal filter assembly, GENie series Specifications Air Flow Rate (with internal pump) Variable Useful Source Life 8 hours / vial Warm-up time (to 90%) Approx. 5 minutes. L x W x H 5.00 x 3.88 x 3.13 (12.7 x 9.85 x 7.95 cm) Weight 2 lb. (907 g) Operating Temperature 0 C to 50 C Relative Humidity (intermittent use) 0-100% Accuracy ±10% (±5% available) Repeatability ±5% Battery Power 4 alkaline AA Battery Life 5 hours approx. 17

18 CAL 101 CALIBRATION GAS INSTRUMENT Our most economical electrochemical gas instrument. The CAL 101 calibrates different gas detection systems and gases with one instrument. Its field interchangeable calibration gas sources enable the ability to switch gases on the fly and provide a calibration standard for accurately testing Chlorine, Hydrogen Sulfide, Hydrogen and Hydrogen Cyanide sensors. This calibration method is approved under the ISO DIS standards. The CAL 101 is non-hazardous to ship and will not degrade over time. The electrochemical generating source is interchangeable and provides multiple gas and concentration options quickly, safely and easily. By simply inserting the appropriate source in the instrument, the user is ready to calibrate. The CAL 101 is safe and easy to use for even the least accessible detection points. Simply insert the gas generating source and you are ready to calibrate Non-Hazardous shipping Compact hand-held design Low power consumption Interchangeable calibration gases and concentration Lowest cost calibration Alkaline battery powered CAL 101 Gas Options Gas PPM Cl2 Chlorine 1-25 HCN Hydrogen Cyanide 1-25 H2 Hydrogen 1-25 H2S Hydrogen Sulfide 1-25 Flow.5 LPM or 1.0 LPM Concentration Source defined Accuracy ± 10% Available generating life 2 hours Non-hazardous shipping Interchangeable gases No shelf degradation Mass flow feedback No 18

19 H 2 CAL 101 Instrument & Accessories What s Included? CAL 101 Instrument (specify flow) includes flow meter, batteries, carrying case, hose, manual. Instrument CAL 101 Instrument Calibration Sources Part Number Gas Capacity PPM Range 1 25 PPM Cl2 (chlorine) 2 hours Specify* H2 (hydrogen) 2 hours Specify* H2S (hydrogen sulfide) 2 hours Specify* HCN (hydrogen cyanide) 2 hours Specify* Bump Sources Specifications Air Flow Rate 0.5 or 1 LPM Useful Source Life 2 hours Warm-up time (to 90%) Approx. 1 minute L x W x H 5.0 W x 3.5 H x 1.5 D Weight 1 lb. (454 g) Operating Temperature 0 C to 50 C Relative Humidity (intermittent use) 0-100% Accuracy ±10% Battery Power 2 alkaline A Battery Life Approx. 4 hrs. (at.5 LPM flow rate) ClO 2 H 2 S HCN Cl Cl2 (chlorine) 350 tests > H2 (hydrogen) 350 tests > H2S (hydrogen sulfide) 350 tests > HCN (hydrogen cyanide) 350 tests >10 Accessories Hard Body Case Replacement Parts Nylon Carrying Case External flow check assy Outlet Fitting, body (1/8 NPT) quick connect Hose connector, insert (hose barb) quick connect Tool, ACD magnetic tip screwdriver X Hose, with quick connect, 5 19

20 MiniBump CALIBRATION GAS OR BUMP TESTER The MiniBump for intrinsically safe and economical bump testing. The MiniBump is the smallest, most lightweight and adaptive calibration gas source on the market. It is our lowest entry cost product as well as our simplest to use. It is certified to be intrinsically safe for operation in potentially explosive atmospheres. The MiniBump operates with interchangeable generating sources providing either fixed concentration output for calibration, or bump output to drive your detector into alarm for operational verification. Available in hydrogen sulfide, chlorine, hydrogen and hydrogen cyanide. The complete device fits into your shirt pocket and provides the equivalent of 5-58 liter cylinders of gas with each generating source. The MiniBump is approved INTRINSICALLY SAFE by CSA NRTL/C Exia T-6. Interchangeable calibration gases Automatic shut down after each test Alkaline battery powered Disposable generating source ATEX II3G EEx nl IIB T4 approved CSA NRTL/C Exia T-6 approved intrinsically safe with CE mark MiniBump Gas Options Gas PPM Cl2 Chlorine 1-25 HCN Hydrogen Cyanide 1-25 H2 Hydrogen 1-25 H2S Hydrogen Sulfide 1-25 Concentration Source defined Accuracy ± 10% Available generating life Source defined Non-hazardous shipping Interchangeable gases No shelf degradation Mass flow feedback No 20

21 H 2 MiniBump Bump Tester & Accessories MiniBump Instrument, Less Source What s included: MiniBump instrument complete, less source. Sources (Gas Options) Part Number Gas Capacity (Hrs) PPM Range 1 25 PPM X Cl2 (chlorine) 5 Specify* X H2 (hydrogen) 5 Specify* X H2S(hydrogen sulfide) 5 Specify* X HCN(hydrogen cyanide) 5 Specify* Bump Sources Part Number Gas Capacity (Bump Cycles) Approx. PPM Output Cl2 (chlorine) H2 (hydrogen) H2S (hydrogen sulfide) HCN (hydrogen cyanide) Accessories Wall mount case for MiniBump Hard body carrying case Replacement Parts Screw cap, with hose fitting, MiniBump Battery cover, MiniBump X Hose, with quick connect, 5 Specifications Useful Source Life Source defined Bump Test Time Less than 120 seconds Intrinsically Safe Class 1, Division 1, Groups A, B, C, D L x W x H 4.09 x 2.36 x 1.18 (10.4 x 6.0 x 3.0 cm) Weight 0.5 lb. (220 g) Operating Temperature -40 C to 50 C Relative Humidity (intermittent use) 0-100% Battery Power 2 alkaline AA Battery Life 10 hours H 2 S HCN Cl 2 21

22 QC-50 Calibration Gas Bump Tester CALIBRATION GAS BUMP TESTER Easy, reliable and portable bump testing. The QC-50 utilizes revolutionary technology allowing a functional check (or Bump Test ) as needed or required by law. The unique QuickCheck Vial (QCV) utilizes a stable, safe and reliable delivery method allowing ease of shipment, storage and use. Breaking a QCV ampoule and inserting it into the bulb allows the liquid to absorb into a filter which then diffuses out the gas. Simply squeezing the hand aspirated bulb will allow a test concentration of gas to flow by the gas detector, verifying its operation. Disposable source vials Interchangeable calibration gases QC-50 and Bump Tester, Gas Options & Accessories QC-50 Kit What s included: QC-50, belt pack, manual, 5 hose and 12 QCV vials (specify gas) QC-50 What s included: QC-50, 5 hose, manual. Quick Check Vials (Gas Options) NH3 (Ammonia) 12 Pack HCl (Hydrogen Chloride) 12 Pack C7H8 (Toluene) 12 Pack C6H14 (Hexane) 12 Pack Accessories Hard body carrying case, Replacement Parts X Hose, with quick connect, Nylon carrying case Specifications Useful Vial Life Up to 8+ hours per vial Warranty One year Dimensions (QC-50) 2 x 7.2 (5 x 18.4 cm) Dimensions (QCV) 0.4 x 1.3 (1.1 x 3.4 cm) Weight (QC-50) 2.5 oz (75 gm) Weight (QCV).14 oz (4 gm) Operating Temperature 20 C Relative Humidity (intermittent use) 0-100% 22

23 QC-100 Calibration Gas Bump Tester CALIBRATION GAS BUMP TESTER Stable, safe, reliable, adjustable and expandable bump testing. The QC-100 utilizes revolutionary technology allowing a calibration functional check or Bump Test as needed. The unique QuickCheck Vials (QCV) uses a stable, safe and reliable delivery method allowing ease of shipment, storage and use. The QCV used in the QC-100 are small, disposable vials. Breaking the inner ampoule allows the liquid to absorb into a filter which then diffuses out the gas. The motorized pump in the QC-100 provides a continuous output of calibration check gas, and the needle-valve allows users to adjust the amount of gas being generated. This gas concentration can be checked against a calibrated instrument for higher accuracy, or simply used as a bump test device. Simple to use Adjustable output CE Approved Alkaline battery powered Non-hazardous shipping and disposal Expandable when future gases are added QC-100 Bump Tester, Gas Options & Accessories QC-100 Instrument What s included: QC-100 instrument, batteries, 5 hose and manual QC-100 Kit What s included: QC-100 instrument, belt pack, manual, 5 hose and 12 QCV vials (specify gas). Quick Check Vials (Gas Options) NH3 (Ammonia) 12 Pack HCl (Hydrogen Chloride) 12 Pack C7H8 (Toluene) 12 Pack C6H14 (Hexane) 12 Pack Accessories Hard body carrying case, Replacement Parts X Hose, with quick connect, Nylon carrying case Specifications Useful Vial Life Up to 8+ hours per vial Warranty One year Dimensions (QC-100) 6.0 x 2.3 x 1.2 (15.2 x 5.8 x 3.0 cm) Dimensions (QCV) 0.4 x 1.3 (1.1 x 3.4 cm) Weight (QC-100) 8 oz (220 gm) Weight (QCV).14 oz (4 gm) Operating Temperature 5-50 C Relative Humidity (intermittent use) 0-100% Battery Power 2 Alkaline AA Battery Life 10 hours 23

24 Standard Warranty Gas Calibration Instruments We warrant gas calibration equipment manufactured and sold by us to be free from defects in materials, workmanship and performance for a period of one year from the date of shipment. Any parts found defective within that period will be repaired or replaced, at our option, free of charge, F.O.B. factory. This warranty does not apply to those items which by their nature are subject to deterioration or consumption in normal service, and which must be cleaned, repaired, or replaced on a routine basis. Such items may include: a. Electrochemical type generating sources b. Quick Check Vials (QCV) c. Batteries d. Fuses e. Air Filters All sources are warranteed for one year or the life of the source, whichever comes first. Warranty is voided by abuse including rough handling, mechanical damage, alteration or repair procedures not in accordance with the instruction manual. This warranty indicates the full extent of our liability, and we are not responsible for removal or replacement costs, local repair costs, transportation costs or contingent expenses incurred without our prior approval. Advanced Calibration Designs, Inc. s obligation under this warranty shall be limited to repairing or replacing, and returning any product which shall be returned to Advanced Calibration Designs, Inc. at its manufacturing facilities, with transportation charges prepaid, and which Advanced Calibration Designs, Inc. s Material Review Board examination shall disclose to its satisfaction to have been defective. This warranty is expressed in lieu of any and all other warranties and representations, expressed or implied, and all other obligations or liabilities on the part of Advanced Calibration Designs, Inc. including, but not limited to, the warranty of fitness for a particular purpose. In no event shall Advanced Calibration Designs, Inc. be liable for direct, incidental or consequential loss or damage of any kind connected with the use of its products or failure of its products to function or operate properly. 24

25 25

26 Advanced Calibration Designs 2024 W McMillan St Tucson AZ USA Phone: Toll Free: Fax: Web: goacd.com acd@goacd.com

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc. Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up

More information

Vers Gas Generator. Release III INSTRUCTION MANUAL. Advanced Calibration Designs, Inc.

Vers Gas Generator. Release III INSTRUCTION MANUAL. Advanced Calibration Designs, Inc. Advanced Calibration Designs, Inc. Vers ersacal Gas Generator Release III Advanced Calibration Designs, Inc. 2024 W. McMillan Street Tucson, Arizona 85705 U.S.A. Telephone: (520) 290-2855 Fax: (520) 290-2860

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual 30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual 30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Gas-Detection Instruments

Gas-Detection Instruments ALTAIR 5X Multigas Detector Accessories SPARE PARTS/ REPLACEMENTS CALIBRATION 10114835 Battery pack assembly, rechargeable 10114837 Battery pack, alkaline (includes belt clip) 10114839 Battery pack, rechargeable,

More information

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Portable Gas Monitor GX User Maintenance Manual (H4-0050) H4E-0050 Portable Gas Monitor GX-8000 User Maintenance Manual (H4-0050) Need of Maintenance and Servicing This gas monitor must be maintained in a normal state at all times to prevent accidents due to

More information

CALIBRATION KIT. Instruction Manual

CALIBRATION KIT. Instruction Manual CALIBRATION KIT Instruction Manual 2 CALIBRATION KIT CALIBRATION KIT 3 Table of Contents General description....4 Getting Started....4 GG-NH3....5 GG-NH3-2%....6 GG-CO....7 GG-CO2...8 GG-CL2...9 GG-H2-EC....

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

PRECISION GAS MIXTURES

PRECISION GAS MIXTURES PRECISION GAS MIXTURES 2. Company Profile 3. Reactive Gases 4. Regulators 5. Cylinders 6. Gas Mixtures 7. Accessories PRECISION GAS MIXTURES GASCO Affiliates, LLC is a leading manufacturer of Precision

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) WARRANTY CLAUSE METROSONICS warrants each new cl-304 manufactured and sold to be free from defects in material, workmanship and construction, except for batteries which may be contained therein, and that

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

RAM 4021-DPX Operation Manual

RAM 4021-DPX Operation Manual RAM 4021-DPX Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS ABL 4021-DPX / RAM 4021-DPX For Your Safety... 3 Description... 3 Setup Mode... 4 Lights/Alarms... 4 Operation...

More information

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs AIR FLOW CALIBRATORS FOR MOST AIR MONITORING PROGRAMS World Calibrator PC Version World Calibrator VFD Version Compact Digital Calibrator

More information

GasLab SAN-102 Micro Oxygen Monitor User Manual

GasLab SAN-102 Micro Oxygen Monitor User Manual GasLab SAN-102 Micro Oxygen Monitor User Manual The GasLab SAN-102 is a wearable, personal safety meter designed to monitor ambient oxygen levels in real time. It is designed to protect workers in confined

More information

GAS DETECTION: CALIBRATION GAS

GAS DETECTION: CALIBRATION GAS ENVIRONMENTAL SURVEY/PURGING MONITORS GAS DETECTION: CALIBRATION GAS Gas Mixtures Non-Reactive Single & Two-Gas Mixtures 98 Reactive Single & Two-Gas Mixtures 98 Non-Reactive Multi Mixtures 99 Reactive

More information

Automatic Test and Calibration Station

Automatic Test and Calibration Station Automatic Test and Calibration Station Cost effective calibration and bump test management The MicroDock II is an easy, cost-effective way to bump-test, calibrate, charge and manage records for BW portable

More information

RAM 4021 Operation Manual

RAM 4021 Operation Manual RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For your safety...3 Description...3 Set-up mode...4 Annunciator lights/alarms...4 Operation...5 Calibration...6

More information

MODEL CALIBRATION GAS DELIVERY SYSTEM

MODEL CALIBRATION GAS DELIVERY SYSTEM MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM APPLICABILITY & EFFECTIVITY This

More information

Gas-Detection Instruments

Gas-Detection Instruments Gas-Detection Instruments Regulators Regulators are used to ensure you receive the required flow of calibration gas for your application. MSA regulators save customers money by delivering calibration test

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

RAM Operation Manual

RAM Operation Manual RAM 4021-1 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-1 For Your Safety... 2 Description... 2 Setup Mode... 3 Lights/Alarms... 3 Operation... 4 Calibration...

More information

O3 3E 1 F Gas Sensor Module

O3 3E 1 F Gas Sensor Module Product Information Pack O3 3E 1 F Gas Sensor Module (Ozone) CONTENTS Product Data Sheet Product Specification 2 Poisoning and Cross Sensitivities 3 Operating Instructions Introduction 4 Electrostatic

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

Precision Calibration Gas

Precision Calibration Gas Precision Calibration Gas Setting Standards - Exceeding Expectations GASCO is an organization characterized by integrity, competence, cooperation and professionalism. We continually strive to earn customers

More information

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4

More information

Phosgene Sensor. Sensoric COCl2 3E 1

Phosgene Sensor. Sensoric COCl2 3E 1 Phosgene Sensor 1 FEATURES Amperometric 3 electrode sensor cell Fixed organic electrolyte High reliability TYPICAL APPLICATIONS Ambient monitoring of TLV levels Chemical Industry, Homeland Security PART

More information

RGC-IR Remote Gas Calibrator for IR400

RGC-IR Remote Gas Calibrator for IR400 Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by

More information

GasLab SAN-102 Micro Oxygen Monitor User Manual

GasLab SAN-102 Micro Oxygen Monitor User Manual GasLab SAN-102 Micro Oxygen Monitor User Manual The GasLab SAN-102 is a wearable, personal safety meter designed to monitor ambient oxygen levels in real time. It is designed to protect workers in confined

More information

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Calibration Requirements for Direct Reading Confined Space Gas Detectors : Calibration Requirements for Direct Reading Confined Space Gas Detectors However, the definition of bump test has always been a little slippery. Some manufacturers differentiate between a bump test that

More information

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL - Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL - Table of Contents 1. Introduction 3 2. Instrument Setup 4 2.1 Instrument Checklist 4 2.2 Optional Accessories 4 2.3 Gas Concentration Ranges Available

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

PERSONAL AIR BREATHING UNIT

PERSONAL AIR BREATHING UNIT PERSONAL AIR BREATHING UNIT Operation & Maintenance Manual MARTECH SERVICES C O M P A N Y 1-800-831-1525 Table of Contents INTRODUCTION: Page 2 COMPONENTS DRAWING: Page 3 START UP: Page 4 OPERATION: Page

More information

User Manual. GPL 3000 e. gas detector

User Manual. GPL 3000 e. gas detector User Manual GPL 3000 e gas detector Table of contents Application...4 Unit ppm, Vol.%...5 Operation elements GPL 3000 e...6 Gas Sensor...7 Measurement range...8 LED allocation...8 Turning on the GPL 3000

More information

Non-refillable canister solutions for ultimate portability

Non-refillable canister solutions for ultimate portability Non-refillable canister solutions for ultimate portability Making the difference Air Products has been serving customers in the analytical, testing and calibration markets for decades. Through these close

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide / Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale

More information

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user. GAS DETECTION Cost of Ownership In today's competitive marketplace the initial cost of any capital equipment is important to the end user but of equal importance is the ongoing cost of ownership. In many

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

Nonrefillable Cylinders

Nonrefillable Cylinders Nonrefillable Cylinders A DIVISION OF NORCO, INC. Norlab, the Specialty Gas Division of Norco, Inc., has been producing and distributing calibration mixtures and pure specialty gases in refillable and

More information

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2 GAS ANALYSER OXYBABY 6.0 for or Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and accurate

More information

SPECIFICATIONS APCEPH1

SPECIFICATIONS APCEPH1 APCEPH1 ph CONTROLLER SPECIFICATIONS APCEPH1 Input voltage 120 Volts AC Maximum amperage 14.5 amps @ 120 VAC ph Accuracy +/- 0.2 ph ph Control range Adjustable 4.5 8.5 ph Weight < 1 lbs Dimensions 3" x

More information

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual Bante820 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante820 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante820 portable dissolved oxygen

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Operation and Maintenance Manual GDS 49 Remote 4 20mA Sensor Transmitter for Toxic Gases GDS Corp. 1245 Butler Road League City, TX 77573 409 927 2980 409 927 4180 (Fax) www.gdscorp.com CAUTION: FOR SAFETY

More information

CAPITAL CONTROLS SERIES NXT3000

CAPITAL CONTROLS SERIES NXT3000 CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a

More information

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER) DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER) 0-3, 0-15, 0-30 & 0-70 LPM ASSEMBLY INSTRUCTIONS & INSTRUCTIONS FOR USE R219P87-400 (0-70 LPM) R219P88-400 (0-30 LPM) R219P79-400 (0-15 LPM) R219P99-400

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Additel 761 Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure modules Built-in

More information

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual GG-VL2-NH3 AMMONIA VENT LINE SENSOR Installation and Operation Manual 2 GG-VL2-NH3 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

Pressure Relief Valve Instruction Manual

Pressure Relief Valve Instruction Manual CVR3-M0_062017 Pressure Relief Valve Instruction Manual MODEL: CVR3 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website:

More information

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

OPERATION AND MAINTENANCE INSTRUCTION MANUAL OPERATION AND MAINTENANCE INSTRUCTION MANUAL AA-74 AIRPAC COMPRESSOR - 120 VOLT - TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Operation...........................2

More information

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc. Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED A Division of Norco, Inc. Located in Boise Idaho, Norlab has been producing and distributing calibration gas mixtures and specialty gases in refillable

More information

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a

More information

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation Page 1 of 19 : SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor Description and Principle of Operation The photoacoustic multi-gas monitor (INNOVA 1412, Innova AirTech Instruments, Denmark) is a highly

More information

Heavy Duty Dissolved Oxygen Meter

Heavy Duty Dissolved Oxygen Meter User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com Introduction Congratulations

More information

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features Features Pressure ranges from 0 to 5 and 0 to 3000 psi (0 to 400 mbar and 0 to 210 bar) xi and 7250i provide advanced precision of 0.005% of reading provides 0.003% of full scale precision Stability: 0.0075%

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuum-operated, solution-feed gas

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5523 Liquid to Gas Separator Users Manual PN 3952355 November 2010 2010 Fluke Corporation. All rights

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale

More information

ADT 761 Automated Pressure Calibrator

ADT 761 Automated Pressure Calibrator 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com With a built-in high performance electronic pump and precision pressure controller,

More information

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual Model DPC3500 Continuous Low Range Dew Point Analyzer Operations Manual Please read, understand, and follow these instructions before operating this equipment. Super Systems, Inc. is not responsible for

More information

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Model B12-69 2-Wire Wet Oxidant Gas Transmitter Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph

More information

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures Nitrogen Advantage nitrogen tire inflation system, 4/7/14/21 CFM Better Tire Pressure Retention Improved Fuel Economy Extended Tread Life Elimination of Oxidation Reduction in Tire Failures 2 The Nitrogen

More information

210 Series Transmitter with External Electrochemical Sensor

210 Series Transmitter with External Electrochemical Sensor 210 Series Transmitter with External Electrochemical Sensor INSTRUCTIONS Installation and Operation of the AMC-210 Series Transmitter with External Electrochemical Sensor IMPORTANT: Please read these installation

More information

ITEMS REQUIRED TO CALIBRATE A STANDARD GAS DETECTOR USING A 34L, 58L, 78L OR 103L CYLINDER OF GAS:

ITEMS REQUIRED TO CALIBRATE A STANDARD GAS DETECTOR USING A 34L, 58L, 78L OR 103L CYLINDER OF GAS: Standard Calibration ITEMS REQUIRED TO CALIBRATE A STANDARD GAS DETECTOR USING A 34L, 58L, 78L OR 103L CYLINDER OF GAS: Grey calibration adapter plug with o-ring and two zeroing port nozzles. Fits industry

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

AUTOMATIC HOSE TEST UNIT, TYPE SPU

AUTOMATIC HOSE TEST UNIT, TYPE SPU VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE

More information

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel: PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)

More information

Ever. EverFlo. Home oxygen system. Oxygen simplified

Ever. EverFlo. Home oxygen system. Oxygen simplified Ever EverFlo Home oxygen system Oxygen simplified Freedom of choice We offer a full line of oxygen concentrators EverFlo Q ultra quiet oxygen concentrator with all of the features of our EverFlo, plus:

More information

AA GWR Water Retention Meter for Accurate Measurement of Water Retention

AA GWR Water Retention Meter for Accurate Measurement of Water Retention AA GWR Water Retention Meter for Accurate Measurement of Water Retention Principle of Measurement: Coating color is poured into a test cell and separated from a blotting paper with a filter. The cell is

More information

Deadweight Tester / Pressure Balance High pressure up to 5,000 bar / 70,000 psi CPB5000-HP. Applications. Special features. Description. Rel.

Deadweight Tester / Pressure Balance High pressure up to 5,000 bar / 70,000 psi CPB5000-HP. Applications. Special features. Description. Rel. High up to 5,000 bar / 70,000 psi CPB5000-HP Rel. 20150206 Applications Primary standard for defining the scale in a range up to 5,000 bar Reference instrument for testing, adjusting and calibrating measuring

More information

Portable oxygen concentrator

Portable oxygen concentrator Table of contents G3 1. Introduction 2 2. Important Safety Rules 3 3. Unpack your Lovego 4 4. User Controls & System Status Indicators 5 5. Quick Start 6 6. How to operate 7 7. How to operate with battery

More information

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a ATMOSPHERE APS TM Series Haze Generator MAX APS TM Series Fog Generator USER GUIDE No: 120815, Revision A/a MADE IN CANADA FABRIQUÉ AU CANADA Les Générateurs de Brouillard Ltée / Fog Generators Ltd 10301

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Test pumps. Pressure sources. Good reasons for proper and reliable calibration Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even

More information

Chlorinator MODEL MK-I

Chlorinator MODEL MK-I Chlorinator MODEL MK-I The New model MK- I is semi automatic gas type. Vacuum operated Solution feed Chlorinator designed to provide a continues & measured quantity of gas while in operation. It is suitable

More information

Operation Manual. Rev. C LPT Low Power Transmitter (Electrochemical Sensor)

Operation Manual. Rev. C LPT Low Power Transmitter (Electrochemical Sensor) Operation Manual Rev. C 2014.04 LPT Low Power Transmitter (Electrochemical Sensor) www.critical-environment.com LPT - Operation Manual Rev. C 2014.04 TABLE OF CONTENTS 1 POLICIES...4 1.1 Important Note...4

More information

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed

More information

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems Oxygen Concentrator Installation and Operation Manual ClearWater Tech, LLC. Integrated Ozone Systems 850-E Capitolio Way, San Luis Obispo, Ca 93401 805-549-9724 Fax: 805-549-0306 E-mail: service@cwtozone.com

More information

Do Not Print This Page.

Do Not Print This Page. Do Not Print This Page. Load 1 sheet of cardstock paper. Print Page 2 - the cover For the body of the text, load 3 sheets of 28lb matte finish paper into the printer. Print pages 3, 5, 7 (Sheet 1, 2, 3)

More information

Dräger X-act 5000 Automatic Dräger Tube Pump

Dräger X-act 5000 Automatic Dräger Tube Pump Dräger X-act 5000 Automatic Dräger Tube Pump The automatic tube pump Dräger X-act 5000 is the first all-in-one solution designed for measurements with Dräger short-term tubes and for sampling tubes and

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

AND OPERATION INSTRUCTIONS

AND OPERATION INSTRUCTIONS ADI 2111-D Certified ISO 9001 MEDICAL FLOWMETER (Back Pressure Compensated Thorpe Tube) INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls

More information

Operation Manual. O2 Quickstick. Oxygen Analyzer

Operation Manual. O2 Quickstick. Oxygen Analyzer Operation Manual O2 Quickstick Oxygen Analyzer 01.11 www.nuvair.com If you have any questions on this equipment please contact Technical Support at: Nuvair 2949 West 5 th St. Oxnard, CA 93030 Phone: 805-815-4044

More information

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by

More information

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations OXYBABY 6.0 for O 2 or O 2 /CO 2 Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for portable, faster and

More information

DPC-30 DPC-100. Reference Manual

DPC-30 DPC-100. Reference Manual DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,

More information

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010 LUDLUM MODEL 239-1F FLOOR MONITOR Revised LUDLUM MEASUREMENTS, INC. 501 OAK ST., P.O. BOX 810 SWEETWATER, TX 79556 325/235-5494 FAX: 325/235-4672 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants

More information

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE R218P15 Industrial R218M15 Rev. D Maxtec TEL (800) 748.5355 2305 S 1070 W FAX (801) 270.5590 Salt Lake City, Utah 84119 www.maxtec.com USA CLASSIFICATION

More information

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use Data sheet Katharometers The ideal equipment for Process Monitoring and Control Designed for continuous industrial use Long working life Suitable for flammable gases CENELEC certified (ATEX) to EExia IIC

More information

Precision digital pressure gauge Model CPG1000

Precision digital pressure gauge Model CPG1000 Calibration technology Precision digital pressure gauge Model CPG1000 WIKA data sheet CT 10.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service

More information

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features GE Sensing & Inspection Technologies Series 7050 Ruska Digital Pressure Indicator Features Pressure ranges from 0 to 10 inh2o and 0 to 1500 psi (0 to 25 mbar and 0 to 100 bar) Choose from three models:

More information

GAS ANALYSER OXYBABY M+ for O 2. or O 2 /CO 2. standard version

GAS ANALYSER OXYBABY M+ for O 2. or O 2 /CO 2. standard version GAS ANALYSER OXYBABY M+ for O 2 or O 2 standard version Cordless hand held oxygen or combined oxygen and carbon dioxide analyser for checking modified atmospheres in food packs. The ideal instrument for

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values Operations Manual Please read, understand, and follow these instructions before operating this equipment.

More information

SEC Signature DIR Process Monitor

SEC Signature DIR Process Monitor SEC Signature DIR Process Monitor Instruction and Operation Manual Sensor Electronics Corporation 12730 Creek View Avenue Savage, Minnesota 55378 USA (952) 938-9486 Fax (952) 938-9617 email sales@sensorelectronics.com

More information

In Vivo Scientific, LLC INSTRUCTION MANUAL

In Vivo Scientific, LLC INSTRUCTION MANUAL CO 2 Controller In Vivo Scientific, LLC INSTRUCTION MANUAL CONTENTS CONTENTS...1 ABOUT THIS MANUAL...2 INTRODUCTION...2 Cautions and Warnings...2 Parts List...2 Unpacking...2 INSTRUMENT DESCRIPTION...3

More information

AIR-SAVER G1 AIR-SAVER G2 LOCATOR LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

AIR-SAVER G1 AIR-SAVER G2 LOCATOR LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS AIR-SAVER G1 AIR-SAVER G2 LOCATOR LOCATOR-EV ENVIRONMENT ADDING VALUE SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS AIR SAVING PRODUCTS INDEX Chapter

More information