1 Dosing equipment REF Description Picture Technical data Page D Piston dosage ECON 4, 6, 7, 0 VDC approx. 45W (40%ED/S) g/0sec Tolerance ±0% Vmax to 60km/h Price **** Pmin: 6bar D4 P5 piston dosage Pneumatically activated totally enclosed Ca.0 Nl/min air consumption g/0sec Tolerance ±0% 5 Vmax to 60km/h Price ** 4, 6, 7, 0 VDC approx. 60W ( 40%ED/S) D5 N45 piston dosage takting electrically g/0sec 6 Tolerance ±0% Vmax to 400km/h Price **** D6 Z4 Cell wheel dosage with brushes motor D7 Z4 Cell wheel dosage with brushless motor 4 VDC approx. 50W ( 00%ED) g/0sec Tolerance ±0% (±0%) Vmax to 400km/h Price **** 4 VDC approx. 50W ( 00%ED) g/0sec Tolerance ±5% Vmax to 400km/h Price ***** 7 8

2 Technical data piston dosage ECON Magnet-activated piston dosage has been developed for precise batching of sand- and for the safe blocking D of the sand container. The functional principle was developed in a similar way to that of a piston-operated valve. It is activated by a hoist magnet. The sand amount can be adjusted via the hoist setting of the magnet accessible from the outside. The interruption of the sand flow is operated by a spring 4 Dosage housing Hoist magnet (can be rotated 4 x 90 ) 4 Adjusting screw modular structure: horizontal, perpendicular, rotating Operative voltage 4, 6, 7 und 0VDC * ± 0% Power approx. 40W (40% ED / S) Plug Valve plug design A with protective circuit DIN EN (replaces DIN 4650) * quantity g/0sec ± 0% infinitely adjustable during nominal voltage * 0,5 to 0bar (type. 0,5 bar by supply with small compressors and/or 6 bar over pressure control valves by central compressed air feed circuit ISO 857: Particle class: 7 (size <= 40µm/ concentration <= 0 mg/m ³) Air humidity class: (dew point -40 C/min. 5 K under the deepest IP66 to 60km/h EN 5055 (T) The version of equipment needs less maintenance. Only regular function controls are to be carried out. For main overhaul the equipment components are to be submitted to a complete examination. The changing intervals depend on the real conditions of service.

3 Technical data cylinder dosage P5 Pneumatically activated dosage piston has been developed for precise batching of sand and for the safe blocking of the sand container. The D4 P5 dosage was specially designed for an easy and quick integration in vehicles. This property is particularly important in the conversion of existing vehicles in order to make the sanding system compatible to the current standards (TSI, GMRT46, B0). The functional principle was developed in a similar way to that of a piston operated valve. It is activated by a pneumatic cylinder. The sand amount can be continuously adjusted via the hoist setting of the magnet accessible from the outside. The interruption of the sand flow takes places by the operation of a spring. All crucial components are totally enclosed against external influences (e.g. crushed stone flight). Dosage housing 4 Pneumatic cylinder 4 Adjusting screw quantity Adjustment range : 00g/0s 800 g/0s * st stage : 400g/0s ±00g/0s / nd stage : 650g/0s ±50g/0s According to BN 98 4 acc. to ISO 857-:00 Air consumption Weight Particle class: 7 (size <= 40µm/concentration <= 0 mg/m ³) Air humidity class: (dew point -40 C/min. 5 K under the deepest st stage = 6 bars (±0,5 bar) nd stage = 8 bars (±0,5 bar) approx. 0 to 60km/h EN 5055 (T) -5 C +80 C,6kg The version of equipment needs less maintenance. Only regular function controls are to be carried out. For main overhaul the equipment components are to be submitted to a complete examination. The changing intervals depend on the real conditions of service.

4 Technical data piston dosage N45 Magnet-activated piston dosage has been developed for precise batching of sand- and for the safe blocking of the sand container. The functional principle was developed in a D5 similar way to that of a piston-operated valve. It is activated by a hoist magnet. The setting of the sand amount is about the relationship between ON-and OFF-time. The pulse signal is generated in the vehicle control or over a programmable time delay relay with semiconductor. The interruption of the sand flow takes place by the operation of a spring Dosage housing Hoist magnet modular developed: horizontal, perpendicular, rotating Operating voltage 4, 6, 7 and 0VDC * ± 0% Power approx. 60W (40% ED / S) time in/time out Connection/plug quantity >70ms / >60ms open cable end/ilme plug connector (or customized) g/0sec ± 0% during nominal voltage * 0,5 to 0bar (type. 0,5 bar at supplies by small compressors and/or 6 bar over pressure control valves by central compressed air feed circuit ISO 857: Particle class: 7 (size <= 40µm/concentration <= 0 mg/m ³) Air humidity class: (dew point -40 C/min. 5 K under the deepest IP66 to 400km/h EN 5055 (T) The version of equipment needs less maintenance. Only regular function controls are to be carried out. For main overhaul the equipment components are to be submitted to a complete examination. The changing intervals depend on the real conditions of service.

5 Technical data cell wheel dosage Z4 Cell-wheel dosage has been developed to precisely batch the sand and safely block the sand container. The functional principle was developed in a similar way to that of a cellwheel lock. It is activated via a DC transmission motor. The sand amount is adjustable via D6 the RPM setting for the motor accessible from outside. The interruption of the sand flow takes place by shutting off the motor. Dosage housing Cells modular developed: horizontal, perpendicular, rotating Operating voltage 4VDC * ± 0% Power Connection/plug quantity approx. 50W (00% ED) open cable end/ilme plug connector (or customized) g/0sec ± 0% with nominal voltage (±0% are only attainable with a stabilized electrical system, otherwise the tolerance is equal to the proportional voltage fluctuation) * 0,5 to 0bar (type. 0,5 bar by supply with small compressors and/or 6 bar over pressure control valves with central compressed air feed circuit ISO 857: Particle class: 7 (size <= 40µm/concentration <= 0 mg/m ³) Air humidity class: (dew point -40 C/min. 5 K under the deepest IP40 (only for the assembly inside the vehicle) To 400km/h EN 5055 (T) The version of equipment needs less maintenance. Only regular function controls are to be carried out. For main overhaul the equipment components are to be submitted to a complete examination. The changing intervals depend on the real conditions of service.

6 Technical data cell wheel dosage Z4 Cell-wheel dosage has been developed to precisely batch the sand and safely block the sand container. The functional D7 principle was developed in a similar way to that of a cell-wheel lock. It is activated via a brushless DC transmission motor. The sand amount is adjustable via the RPM setting for the motor accessible from outside. The sand quantity is directly proportional to the motor speed. The control happens either by stage over digital entries (binary up to 8 stages) or an analogue current (4-0mA) or tension interface (0-0VDC). The sand characteristic can be manipulated at will by analogical functioning up to 0 supporting places. The interruption of the sand flow takes place by shutting off the motor. Dosage housing Cell wheel modular developed: horizontal, perpendicular, rotating Operating voltage 4VDC * ± 0% Power Connection/plug approx. 50W (00% ED) Ilme plug connector (or customized) quantity g/0sec ± 5% by nominal voltage * 0,5 to 0bar (type. 0,5 bar for supply by small compressors and/or 6 bar over pressure control valves by central compressed air feed circuit ISO 857: Particle class: 7 (size <= 40µm/concentration <= 0 mg/m ³) Air humidity class: (dew point -40 C/min. 5 K under the deepest z IP66 to 400km/h EN 5055 (T) The version of equipment needs less maintenance. Only regular function controls are to be carried out. For main overhaul the equipment components are to be submitted to a complete examination. The changing intervals depend on the real conditions of service.

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

SPCH/ Blowing block

SPCH/ Blowing block > > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment) Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

2/ Port G1/4

2/ Port G1/4 CATALOGUE > Release 8.8 > Series ER100 digital electro-pneumatic regulators Series ER100 digital electro-pneumatic regulators Port G1/4 Compact design Digital display Analog and digital input Programmable

More information

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP 00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle

More information

MANUAL KPS Pressure Control Valve

MANUAL KPS Pressure Control Valve TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006

More information

Mass Flow Meter (MFM) for gases

Mass Flow Meter (MFM) for gases Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

Digital electro-pneumatic regulators Series ER100

Digital electro-pneumatic regulators Series ER100 CATALOGUE > Release 8.2 Digital electro-pneumatic regulators Series ER100 TREATMENT > Digital electro-pneumatic regulators Series ER100 Port G1/4» Compact design» Digital display» Analog and digital input»

More information

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20) VA 420 new The affordable consumption counter for compressed air and gases R 1 /4 (DN 8) DN 15 R 3 /4 (DN 20) DN 25 R 1 1 /4 (DN 32) DN 40 R 2 (DN 50) With mit und and ohne without Flansch flange Intelligent

More information

Visualize Nitrogen Gas Consumption

Visualize Nitrogen Gas Consumption Air Flow Monitor EWA2 SERIES Conforming to EMC Directive (all models) & Pressure Equipment Directive (AEWA2150/2200 only) Visualize Nitrogen Gas Consumption Small pipe size as Well as Air Consumption!

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

better measurement Simply a question of

better measurement Simply a question of Simply a question of better measurement SCHMIDT Flow Sensor SS 20.600 The powerful industrial professional for demanding applications involving air and gases. Industrial processes Pneumatic technology

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Direct flow measurement with CMOSens technology for nominal flow rates from 0 ml N to 0 l N High accuracy and reproducibility Ingress protection IP Type can be combined

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type can be combined with... Direct flow measurement with CMOSens - Technology for nominal flow rates from 20 ml N /min to 80 l N /min (N 2 ) High accuracy and reproducibility

More information

Pneumatic turret stop with 6, 8 and 12 stop positions for automation

Pneumatic turret stop with 6, 8 and 12 stop positions for automation SOMATEC Sondermaschinen-Vorrichtungen Komponenten für Maschinenbau Klaus Mayer Gewerbestraße 19 88636 Illmensee Telefon 07558/1441 www.somatec-mb.de Telefax 07558/674n Pneumatic turret stop with 6, 8 and

More information

MoveRoll Conveyor Operating and Maintenance Manual

MoveRoll Conveyor Operating and Maintenance Manual MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from ml N /min to 0 l N /min Applicable for aggressive gases Fieldbus option Type 870 can be combined with...

More information

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE

More information

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Type 0404 / 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

Introduction to Pneumatics

Introduction to Pneumatics Introduction to Pneumatics Pneumatics Symbols Air generation and distribution Table 1: Symbols use in energy conversion and preparation ITEM SYMBOL MEANING Compressor SUPPLY Pressure Source Pneumatic Pressure

More information

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

VALVES ISO 5599/1, SERIES IPV-ISV

VALVES ISO 5599/1, SERIES IPV-ISV VALVES ISO 99/1, SERIES IPV-ISV The assembly surface dimensions of ISO1 and ISO2 valves are to ISO99-1. They are available in the -way versions with 2 and 3 positions and with pneumatic or solenoid actuation.

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

pneumatic power clamps

pneumatic power clamps pneumatic power clamps Features Király Trading KFT H-1151 Budapest Mogyoród útja 12-14 E-mail:_agi@kiralytrading.hu Your requirements Power element of machines, tools and devices for the following applications:

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation 2/2- and 3/2-way cartridge solenoid valve 2/2- und 3/2-Wege-Cartridge-Magnetventil Électrovanne cartridge à 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the

More information

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT

More information

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2 Centered (Default) Proportional damper actuator, non-spring return, Multi-Function Technology Torque min. Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) For proportional modulation of dampers in HVC systems. The is

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm > Series CGPT self-centering parallel grippers with T-guide Series CGPT self-centering parallel grippers with T-guide Single and double acting, magnetic, self-centering Bores: ø 6, 20, 25, 32, 40 mm New

More information

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale EPR-3000 High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale General Specifications PRECISE CONTROL UP TO 3000 PSI The Equilibar EPR-3000 dual valve pressure controller

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from

More information

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0 High Accuracy Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N Thermal Mass Flow Meter for Compressed Air and Gases measuring monitoring analysing KMT Measuring range: 0.32... 63 m3n/h... 3.5... 1400 m3 N /h Accuracy: ±2,5% of reading + 0,15% of full scale p max :

More information

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

Model PDT Dewpoint Transmitter

Model PDT Dewpoint Transmitter Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8626 can be combined with Inline MFC for full scale rates from 25 l N /min to 1.500 l N /min; 1/4 to 3/4 High accuracy Short settling time Fieldbus option Type

More information

Digital dead-weight tester Model CPD8500

Digital dead-weight tester Model CPD8500 Calibration Digital dead-weight tester Model CPD8500 WIKA data sheet CT 32.05 Applications Calibration laboratories Avionics/Aerospace equipment manufacturers Precision pressure sensor manufacturers Calibration

More information

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES SENSORS FOR MASS FLOW AND PRESSURE CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES INTRODUCTION Bronkhorst High-Tech BV is the worldwide pioneer in the field of low flow liquid metering

More information

WHITEPAPER. The flowplus 16 Pressure Sensor. Physical Principles and Function

WHITEPAPER. The flowplus 16 Pressure Sensor. Physical Principles and Function The flowplus 16 Pressure Sensor Physical Principles and Function Sensors (from the Latin "Sensire") are devices by means of which it is possible to detect physical or chemical properties of materials.

More information

Digital deadweight tester Model CPD8500

Digital deadweight tester Model CPD8500 Calibration technology Digital deadweight tester Model CPD8500 WIKA data sheet CT 32.05 Applications Calibration laboratories Avionics/ Aerospace equipment manufacturers Precision pressure sensor manufacturers

More information

PZN-plus. Application example. Pneumatic 3-Finger Centric Gripper Universal Gripper. Sizes Gripping force 580 N..

PZN-plus. Application example. Pneumatic 3-Finger Centric Gripper Universal Gripper. Sizes Gripping force 580 N.. PZN-plus Sizes 40.. 300 Weight 0.43 kg.. 43.5 kg Gripping force 580 N.. 38000 N Stroke per finger 3 mm.. 35 mm Workpiece weight 2.9 kg.. 190 kg Application example Insertion tool for assembling small to

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

DATA PD , DR3... Product PD Unloader Valves. Function. Technical Features DR3510 DR3575

DATA PD , DR3... Product PD Unloader Valves. Function. Technical Features DR3510 DR3575 Commercial Vehicle Systems Product Doc. No. Y2042 DATA (EN - Rev. 000) PD-07-00 PD-07-00 Function 048042209000 The Unloader Valve is used to control the maximum pressure of the compressed air delivered

More information

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries. VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

Precision Mass Flow Meters / Controllers for Liquids and Gases

Precision Mass Flow Meters / Controllers for Liquids and Gases CORI-FLOW TM Precision Mass Flow Meters / Controllers for Liquids and Gases Introduction Bronkhorst Cori-Tech B.V. manufactures precise, compact Mass Flow Meters and Controllers for gases and liquids,

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

Bypass Mass Flow Controller (MFC) for gases

Bypass Mass Flow Controller (MFC) for gases Bypass Mass Flow Controller (MFC) for gases Bypass MFC with Capillary technology for nominal flow rates from ml N /min to l N /min Suitable for aggressive gases Fieldbus option Type 870 can be combined

More information

Test and Adjustment Instructions Compressed Air Processing System Air Processing Unit (APU)

Test and Adjustment Instructions Compressed Air Processing System Air Processing Unit (APU) Test and Adjustment Instructions Compressed Air Processing System Air Processing Unit () 1st issue 8150004983 815 000 498 3 This document is not covered by a revision service. New versions can be found

More information

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Operating Manual LTIA5E Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical data

More information

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG TECHNICAL CHARACTERISTICS Number of ways / positions : 3/2, 3/3, 5/2, 5/3, 5/4 Nominal sizes (ND) : 4, 6, 9, 12 Medium : compressed

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 708 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point range 0.5 to bar (8 to 90 psi) The pressure regulator

More information

Pressure Calibrators. Series PC..., PM...

Pressure Calibrators. Series PC..., PM... Pressure Calibrators Series PC..., PM... SIKA-Precision Pressure Calibrators, Series PC..., PM... We help you, if you are under pressure! Pneumatic pressure calibrators PM 25 A, PM 25 D, PM 110 PIC pressure

More information

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1 ATH 500 M Compact integrated drive Installation in any orientation Water or air cooled CE marked and ROHS compliant Heated version (MT) available for corrosive applicaitons. Pumping speed N 2 He H 2 Ar

More information

Application of EN ISO in electro-pneumatic control systems

Application of EN ISO in electro-pneumatic control systems Application of EN ISO 13849 1 in electro-pneumatic control systems Hazards and measures against hazards by implementation of safe pneumatic circuits These examples of switching circuits are offered free

More information

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N Mass Flow Controller (MFC) for gases Type 8626 can be combined with Inline MFC for nominal flow rates from 25 I N /min to I N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

LEA_EN_PZL Dynamometric Scale. Instruments and Systems for Geotechnical and Structural Monitoring

LEA_EN_PZL Dynamometric Scale.   Instruments and Systems for Geotechnical and Structural Monitoring LEA_EN_PZL8001001 Dynamometric Scale LEA_EN_PZL8001001 Dynamometric Scale Description _ The dynamometric scale is a precise, reliable and rugged instrument. The instrument was installed on different dams

More information

ATM.ECO - Analog Pressure Transmitter

ATM.ECO - Analog Pressure Transmitter Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

Pneumatic Outflow Control

Pneumatic Outflow Control Technical Bulletin Pneumatic Outflow Control Pneumatically powered controls for the precise limitation of the volumes of waste water and rain water Contents Applications... 3 Success features... 4 Technical

More information

Air service units series Y G1/4 to G1

Air service units series Y G1/4 to G1 Air service units series Y Series FY Filter, 12.071 Series RY+ RYP Pressure regulator, 12.076 Series FRY Filter/regulator, 12.080 Series OY Lubricator, 12.083 Series FROY Filter, Regulator, Lubricator

More information

MPRM1690 MPRM2590 MPRM3290

MPRM1690 MPRM2590 MPRM3290 Pinze elettriche radiali a 2 griffe 2-jaw radial electric grippers MPRM 2-jaw radial self-centering electric gripper Plug & play user friendly gripper. No electricity consumption when gripper is engaged.

More information

BULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design.

BULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design. BULLETIN E485A Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design www.rosseuropa.com 1 Glossary Response Time The smallest nominal value difference that causes a change

More information

ACTUATORS AND INSTRUMENTS

ACTUATORS AND INSTRUMENTS ACTUATORS AND 03 ADVANCED ACTUATORS AND FOR A COMPLETE VALVE CONTROL SOLUTION Koso Kent Introl LIMITED (KKI) supplies a full range of advanced actuators and associated instrumentation to complement its

More information

Pneumatic valve islands

Pneumatic valve islands Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented

More information

Compact pressure switches for gas and air

Compact pressure switches for gas and air Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)

More information

Model 601CV. Mass Flow Controller. Product Features:

Model 601CV. Mass Flow Controller. Product Features: Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide GRUNDFOS alldos product information Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide Construction and function Modular system Vacuum regulator for direct mounting

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information