Control Valves, Fittings and Accessories

Size: px
Start display at page:

Download "Control Valves, Fittings and Accessories"

Transcription

1 Control Valves, Fittings and Accessories INTERNATIONAL WS2H* 47 lpm 125 gpm WS2CI 45 lpm 115 gpm WS2EI 45 lpm 115 gpm WS1.5CI 227 lpm 60 gpm WS1.5EI 227 lpm 60 gpm WS1.25* 129 lpm 4 gpm WS1.25CI* 129 lpm 4 gpm WS1.25EI* 129 lpm 4 gpm WS1.25TC* 129 lpm 4 gpm WS1* 102 lpm 27 gpm WS1CI* 102 lpm 27 gpm WS1EI* 102 lpm 27 gpm WS1TC* 102 lpm 27 gpm *Valves shown with optional bypass.

2 INTERNATIONAL 1 Water Specialist Valve Specifications SPECIFICATIONS WS1 - USA ONLY WS1CI 1 bar/15 psi drop 1.7 bar/25 psi drop Tank Applications: Softener Filter (1) Inlet/Outlet Fitting Connections 102 lpm (includes meter and bypass) 102 lpm (includes bypass) Male BSPT Sweat Solvent 102 lpm (includes meter and bypass) 102 lpm (includes bypass) Male BSPT Sweat Solvent Valve Material Cycles Regeneration Operating Pressures Operating Temperatures Meter: Flow Rate Range Volume Range (cubic meters) Totalizer /Upflow 4-4 C lpm m Up to 9 /Upflow 4-4 C lpm m Distributor Pilot O.D. Pipe O.D. Pipe Drain Line Connection Brine Line Connection 4 Male NPT Standard 8 or 1 2 O.D. 4 Male NPT Standard 8 or 1 2 O.D. Mounting Base Options NPSM NPSM Height From Top of Tank 187mm 187mm Shipping Weight 2 Kg 2 Kg Electrical: Supply Voltage Supply Frequency Output Voltage Output Current 20V AC 20V AC 1. Filter tank size 407 lpm per m 2 of bed area/10 gpm of backwash per square foot of bed area 2. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company

3 1 Water Specialist Valve Specifications WS1EI 102 lpm (includes meter and bypass) 102 lpm (includes bypass) Male BSPT Sweat Solvent 4-4 C WS1TC 102 lpm (includes meter and bypass) 102 lpm (includes bypass) Male BSPT Sweat Solvent 4-4 C lpm m Not Applicable O.D. Pipe O.D. Pipe 4 Male NPT Standard 8 or 1 2 O.D. 4 Male NPT Standard 8 or 1 2 O.D NPSM NPSM 187mm 187mm 2 Kg 2 Kg 20V AC 20V AC Valves shown with optional bypass.

4 INTERNATIONAL 1.25 Water Specialist Valve Specifications SPECIFICATIONS WS USA ONLY WS1.25CI 1 bar/15 psi drop 1.7 bar/25 psi drop Tank Applications: Softener Filter (1) Inlet/Outlet Fitting Connections Valve Material Cycles Regeneration Operating Pressures Operating Temperatures Meter: Flow Rate Range Volume Range (cubic meters) Totalizer 129 lpm (includes meter and bypass) 121 lpm (includes bypass) 6-24 diameter / Male BSPT /4-1.5 Sweat /4-1.5 Solvent 4-4 C lpm m 129 lpm (includes meter and bypass) 121 lpm (includes bypass) 6-24 diameter / Male BSPT /4-1.5 Sweat /4-1.5 Solvent Up to C lpm m Distributor Pilot 2mm O.D. Pipe 2mm O.D. Pipe Drain Line Connection Brine Line Connection /4 Male NPT Standard /8 or 1/2 O.D. /4 Male NPT Standard /8 or 1/2 O.D. Mounting Base Options 2-1/2-8 NPSM 2-1/2-8 NPSM Height From Top of Tank 187mm 187mm Shipping Weight w/meter 2 Kg 2 Kg Electrical: Supply Voltage Supply Frequency Output Voltage Output Current 20V AC 20V AC 1. Filter tank size 407 lpm per m 2 of bed area/10 gpm of backwash per square foot of bed area 2. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company

5 1.25 Water Specialist Valve Specifications WS1.25EI 129 lpm (includes meter and bypass) 121 lpm (includes bypass) 6-24 diameter / Male BSPT /4-1.5 Sweat /4-1.5 Solvent 4-4 C 129 lpm (includes bypass) 121 lpm (includes bypass) 6-24 diameter / Male BSPT /4-1.5 Sweat /4-1.5 Solvent 4-4 C WS1.25TC lpm m 2mm O.D. Pipe /4 Male NPT Standard /8 or 1/2 O.D. Not Applicable 2mm O.D. Pipe /4 Male NPT Standard /8 or 1/2 O.D. 2-1/2-8 NPSM 2-1/2-8 NPSM 187mm 187mm 2 Kg 2 Kg 20V AC 20V AC Valves shown with optional bypass.

6 INTERNATIONAL 1.5 Water Specialist Valve Specifications SPECIFICATIONS WS1.5CI WS1.5EI 1 bar/15 psi drop 1.7 bar/25 psi drop Tank Applications: Softener Filter (1) Inlet/Outlet Fitting Connections 227 lpm (includes meter) 189 lpm diameter 12-0 diameter 227 lpm (includes meter) 189 lpm diameter 12-0 diameter 1.5 Female BSPT or NPT 1.5 Female BSPT or NPT Valve Material Cycles Regeneration Operating Pressures Operating Temperatures Meter: Flow Rate Range Volume Range Totalizer Lead Free Brass Up to C lpm m Lead Free Brass 4-4 C lpm m Distributor Pilot 50mm O.D. or 1.90 O.D. Pipe 50mm O.D. or 1.90 O.D. Pipe Drain Line Connection Brine Line Connection 1.25 Female NPT with 4 Male NPT Standard 4 Female NPT 1 2 O.D. Mounting Base Options 4-8 UN 4-8 UN 1.25 Female NPT with 4 Male NPT Standard 4 Female NPT 1 2 O.D. Height From Top of Tank 191mm 191mm Shipping Weight w/meter 9.5 Kg 9.5 Kg Electrical: Supply Voltage Supply Frequency Output Voltage Output Current 20V AC 20V AC 1. Filter tank size 407 lpm per m 2 of bed area/10 gpm of backwash per square foot of bed area 2. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company

7 2 Water Specialist Valve Specifications WS2CI WS2EI WS2H 45 lpm (includes meter) 0 lpm 45 lpm (includes meter) 0 lpm 47 lpm (includes meter) 47 lpm diameter 12-6 diameter diameter 12-6 diameter 18-6 diameter diameter 2 Female BSPT or NPT 2 Female BSPT or NPT 2 Female BSPT or NPT/ 2.5 Groove Lock Lead Free Brass Up to C Lead Free Brass 4-4 C Lead Free Brass Up to C lpm m lpm m lpm liters x mm O.D. or 1.90 O.D. Pipe 50mm O.D. or 1.90 O.D. Pipe 6mm O.D. or 2.75 O.D. Pipe 1.5 Female NPT 1.5 Female NPT 2 Female NPT/ 2.5 Groove Lock 1 Male NPT elbow 4 x 1 Solvent elbow 1 2 O.D. Poly Tube Compression 1 Male NPT elbow 4 x 1 Solvent elbow 1 2 O.D. Poly Tube Compression 1 Male NPT elbow 4 x 1 Solvent elbow 4-8 UN 4-8 UN Quick Disconnect 4-8 UN or 6 Flange or Side Mount 216mm 216mm 280mm 1 Kg 1 Kg 22.7 Kg 20V AC 20V AC 20V AC 24V AC 750 ma

8 1 & 1.25 Control Valve Fittings and Accessories 1 PVC Male NPT Elbow Assembly ¾ x 1 PVC Solvent Elbow Assembly 1 Brass Sweat Assembly Order No. V007 Order No. V Order No. V ¾ Brass Sweat Assembly 1 Plastic Male NPT Assembly 1.25 Plastic Male NPT Assembly Order No. V007-0 Order No. V Order No. V Plastic Male BSPT Assembly 1.25 & 1.5 PVC Solvent Assembly 1.25 Plastic Male BSPT Assembly Order No. V Order No. V Order No. V & 1.5 Brass Sweat Assembly Vertical 90 Adapter Kit Order No. V Order No. V191-01

9 1 & 1.25 Control Valve Fittings and Accessories ¾ SharkBite Assembly 1 SharkBite Assembly ¾ Plastic Male BSPT Assembly Order No. V Order No. V007-1 Order No. V Bypass 1 Straight DLFC w/silencer 1 M x M Straight DLFC Order No. V006 Order No. V Order No. V Straight DLFC without Silencer Auxiliary Microswitch Kit WS1 Series Microswitch Assembly Order V No. V Order No. V009 Order No. V014 Weather Covers Wrench Order No. V V175WC-W White Order No. V175WC-A Almond Order No. V19-02

10 1 & 1.25 Control Valve Fittings and Accessories 1 & 1.25 Motorized Alternating Valve 1 & 1.25 Motorized Alternating Valve Order No. V069FF F x F Order No. V069MM M x M 1 & 1.25 No Hard Water Bypass Valve 1 & 1.25 No Hard Water Bypass Valve Order No. V070FF F x F Order No. V070FM F x M

11 1 & 1.25 Control Valve Fittings and Accessories 1.5 Motorized Alternating Valve 2.0 Motorized Alternating Valve Order No. V071 NPT Order No. V071BSPT BSPT Order No. V06 NPT Order No. V06BSPT BSPT

12 DURAFORM LANE WINDSOR, WISCONSIN USA phone (608) fax (608) sales /customer service fax (800) Form No /20/2008

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS TABLE OF CONTENTS TABLE OF CONTENTS...2 GENERAL RECOMMENDATIONS...2 TROUBLESHOOTING GUIDE...3 EXISTING EASY NEST SYSTEM TROUBLESHOOTING GUIDE...4 COMPONENT

More information

Easy Nest Kits. Installation Suggestions

Easy Nest Kits. Installation Suggestions Easy Nest Kits Installation Suggestions 2 General Recommendations Hydraulics Vacuum breakers should be installed to prevent siphoning. Flexible connectors should follow FRP tank manufacturers recommendations.

More information

Autotrol Performa Filter Valve Series

Autotrol Performa Filter Valve Series TM Autotrol Performa Filter Valve Series 440i Control 940F Control 960F Control Water Conditioning Control System Installation, Operation and Maintenance Manual Table of Contents Installation............................

More information

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement Performa Cv Twin Alternating and High Flow Systems Manual Supplement Table of Contents 1.0 Installation and Start-Up.............. 3 Water Line Connection Brine Tank Turbine Connection Connecting Manifold

More information

Installation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14

Installation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14 Installation and Instructions 2 Product Features 3-6 Key Pad Functions 7 Distributor Information Programming Guide 8 Master Programming Guide 9-14 Dimensional Drawing 15 D-STC & D-SMM Valve Assembly 16-17

More information

265 Series Valve Operation Manual

265 Series Valve Operation Manual 265 Series Valve Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant

More information

Flow Material Length. Weight GPM LPM. Style 3095

Flow Material Length. Weight GPM LPM. Style 3095 Akron Municipal Eductors feature a large, easy to read, and removable metering dial with infinite settings between 0% and 6%. Detents at 1 4, 1 2, 1, 3 and 6%. The Eductors are rated to flow at 200 psi

More information

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank Set Up Instructions for DRS4 Series Single Tank Inspect the packaging of the equipment to confirm that nothing was damaged during shipping. (Figure 1) Remove the resin tank(s) and valve(s) from the packaging.

More information

Duplex Commercial Softeners

Duplex Commercial Softeners Duplex Commercial Softeners Installation, Operation & Maintenance Guide Manual 003.1 Contents Page 1. Unpacking Instructions 3 2. Installation 4 Pre-installation checks Fitting the bottom distribution

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3. Page 1 of 8 1. DESCRIPTION A Viking Pilot Pressure Regulated Deluge System utilizes a Viking Flow Control Valve to control water flow into the deluge system. The flow control valve must be installed with

More information

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1 Commercial Softeners Installation, Operation & Maintenance Guide Manual 002.1 Contents Page 1. Unpacking Instructions 3 2. Installation 3 Pre-installation checks Fitting the bottom distribution system

More information

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. Page 1 of 8 1. DESCRIPTION A Viking Pilot Pressure Regulated Deluge System utilizes a Viking flow control valve to control water flow into the deluge system. The flow control valve must be installed with

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING CONRADER VALVES TANK MATE AUTOMATIC DRAIN VALVE INSTALLATION KIT INCLUDES: TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING WV-1 DRAIN VALVE TOOLS REQUIRED: 3/4 WRENCH **TUBING CUTTERS ** NEEDED TO CUT METAL

More information

Prestige Water Equipment Ltd.

Prestige Water Equipment Ltd. The Prestige range of water softeners complements the range of water pretreatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer

More information

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25

More information

Chloramines Removal Filter CLF20 and CLF35 Models

Chloramines Removal Filter CLF20 and CLF35 Models Chloramines Removal Filter CLF20 and CLF35 Models Operating and Maintenance Manual #51793 Rev. 6/09 Performance and Specifications Recommended Mineral Installation Shipping Item Model Media Flow Rate Tank

More information

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20 table of contents kitchen accessories Air Gaps.............3 Basket Strainers.........3 Disposal Flanges....... 3-4 Faucet Hole Covers....... 4 Soap & Lotion Dispensers.... 4 Water Dispensers........ 4

More information

With 960 Series Control Water Conditioning Control System Installation, Operation and Maintenance Manual

With 960 Series Control Water Conditioning Control System Installation, Operation and Maintenance Manual With 960 Series Control Water Conditioning Control System Installation, Operation and Maintenance Manual Part# AP-5100 AP-5125 AP-5150 Manufactured by: Good Water Warehouse Inc. 1700 E. Walnut Ave Fullerton,

More information

INSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS

INSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS INSTALLATION & START-UP INSTRUCTIONS Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS 1999-2009 QualityWaterForLess.com - 1 - info@qualitywaterforless.com Preface: Thank you for your purchase of a new Water

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

Tech Manual Powerline Softener (PS) Series

Tech Manual Powerline Softener (PS) Series Tech Manual Powerline Softener (PS) Series Models: PS 2161 PS 2465 PS 2472 PS 3072 PS 3657 PS 3672 PS 4272 PS 4872 Page - 1 TABLE OF CONTENTS General Information About this Manual...3 The Powerline Product

More information

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

Workhorse 8 Oxygen System Model No 5665, 5673, 5679 11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse 8 Oxygen System Model No 5665, 5673, 5679 Part Number 1815 Revision B SeQual Technologies San Diego, CA USA Cautions,

More information

NORMAL OPERATING DISPLAYS GENERAL OPERATION

NORMAL OPERATING DISPLAYS GENERAL OPERATION SunTapWat e rsys t e ms WS1Cl ac kwat e rsof t ne r Owne r smanual MAIN COMPONENTS Your water treatment system is a point of entry (POE) system composed of three components: A. The control valve and computer

More information

Distributor Catalog 2. Quick Connect 0.2 mm slot. Metric Connection. Wave Cyber ( Shanghai ) Co., Ltd.

Distributor Catalog 2. Quick Connect 0.2 mm slot. Metric Connection.   Wave Cyber ( Shanghai ) Co., Ltd. Distributor Catalog 2 Quick Connect 0.2 mm slot Metric Connection www.wave-cyber.com Wave Cyber ( Shanghai ) Co., Ltd. TOP MOUNT 6 LATERAL (Φ35MM) DISTRIBUTOR (2 ~ 2 TANKS) QUICK CONNECTION ITEM PART DESCRIPTION

More information

O&M Receiving and Inspection. Storage of Water Treatment Media

O&M Receiving and Inspection. Storage of Water Treatment Media O&M 105.1 Receiving and Inspection 1. Equipment should be checked against the Bill of Lading to verify that the number of pieces received matches those shipped. 2. Equipment should be carefully inspected

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA Q= C. Table 1 - Specifications September 25, 2013 Pressure Regulation 537a 1. Description The Model B-3 Pilot Operated Pressure Control Valve is a factory assembled unit. The unit consists of a Model J-2 Halar coated Flow Control Valve,

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION PVC FASTTAP SADDLES PVC FASTTAP SADDLES for IPS Mains THE ULTIMATE CONNECTION OUTLET 3/4 IPS FEMALE SLIP OR 1 IPS MALE SLIP SOLVENT WELD 1 IPS FEMALE SLIP SOLVENT WELD 3/4 MPT 1 MPT 3/4 FPT MAIN 13/16

More information

US Water Systems Synergy Model 9000/9100/9500 Service Manual

US Water Systems Synergy Model 9000/9100/9500 Service Manual US Water Systems Synergy Model 9000/9100/9500 Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference IMPORTANT PLEASE READ: The information, specifications and illustrations

More information

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax Operation Manual Carbon Filtration 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2 Theory of Operation... 2 1.3 System Illustration...

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems 2 3 PSP-1500 SYSTEM DESCRIPTION Reverse Osmosis RO Reverse Osmosis utilizes the unique properties of a semi-permeable membrane to

More information

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA. Table 1 - Specifications Page 1 of 6 1. DESCRIPTION Model A-3 Pilot Operated Pressure Control Valves are factory assembled units. Each unit consists of a Model H-2 Halar coated Flow Control Valve, a Speed Control Valve, a Model

More information

Build Your Own Flamethrower Step-by-step Manual

Build Your Own Flamethrower Step-by-step Manual Build Your Own Flamethrower Step-by-step Manual Table of Contents: Parts List.. page 1 Operation...page 6 Diagrams. pages 7-9 Parts list: Required: Air tank (large) Pressure washer gun with high-pressure

More information

WITH PUMPMASTER 3+3 PUMPS - 20 AND 50 Kg.

WITH PUMPMASTER 3+3 PUMPS - 20 AND 50 Kg. MOBILE GREASE UNITS WITH PUMPMASTER 3+3 PUMPS - AND Kg. 01 AIR OPERATED OIL PUMPS AND KITS Iquip modit iriuscidunt nos niam ver ip AIR OPERATED PISTON PUMPS FOR OIL AND LUBRICANTS............... 000...

More information

KEG PUMP. Range of Electric Keg Pumps

KEG PUMP. Range of Electric Keg Pumps KP KEG PUMP Range of Electric Keg Pumps Electric Keg (Drum) Pumps for Grease KEG PUMP Versatile range of Interlube electric grease pumps for industrial and off-road applications The KP keg pump is available

More information

SIMPLAIR PIPING TOOL. JXT Company

SIMPLAIR PIPING TOOL. JXT Company SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

Tribomatic II Powder Pump

Tribomatic II Powder Pump Instruction Sheet P/N Tribomatic II Powder Pump WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation.

More information

Compact Transfer Pump

Compact Transfer Pump Munster Simms Engineering, better known under the product brand name Whale, is an independent company engaged in the design, manufacture, marketing and selling of pumps, valves, faucets and plumbing (water

More information

LEAK TROUBLESHOOTING

LEAK TROUBLESHOOTING LEAK TROUBLESHOOTING If you suspect that your TMC isolation system is leaking (most often evidenced by going through air/nitrogen tanks too quickly), this guide will help you to find and fix the problem.

More information

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6 Equipment Affected Technical Bulletin LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6 Ford 4.2L V-6 powered tractors with LPG fuel systems. Part Description Discrepancy Fuel Pressure Lock-off

More information

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1 November 30, 1994 534 a 1. PRODUCT NAME VIKING 2" (50mm), 3" (75mm), 4" (100mm), 6" (150mm) 2. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone:

More information

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint Super-rapid fittings for plastic tubes Series 6000 Sprint Tube external diameters: 3,, 5, 6, 8, 10, 12, 1, 16 mm Fittings threads: metric (M3, M5, M6, M7), BSP (G1/8, G1/, G3/8, G1/2, G3/), BSPT (R1/8,

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE August 2, 2006 Foam 70a 1. DESCRIPTION A Hi-Expansion Foam System is a standard deluge system capable of discharging a foam/water solution automatically through open Hi-Ex Generators. A Hi-Expansion Foam

More information

Magnum Cv Series. Installation and Service Manual

Magnum Cv Series. Installation and Service Manual Magnum Cv Series Installation and Service Manual Table of Contents Section 1.0 Installation Profile Summary - - - - - - - - - - - - - - - - - - - - - - - -1 2.0 Introduction to the Magnum Cv Series -

More information

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SPECIFICATIONS: 10 gpm (38 lpm) Nominal Capacity. Rated up to 4000 psi (275 bar). Port Sizes-Inlet/Outlet #8SAE (3/4-16). Work Ports #8SAE

More information

Series 180. Commercial/Industrial Control System Installation, Operation and Maintenance Manual

Series 180. Commercial/Industrial Control System Installation, Operation and Maintenance Manual Series 180 Commercial/Industrial Control System Installation, Operation and Maintenance Manual Table of Contents Installation............................ 3 Plumbing Inlet and Outlet Piping Drain Line Piping

More information

Laboratory Flowmeters

Laboratory Flowmeters Laboratory Flowmeters Wide selection of flow ranges measure air from 0.02 ml/min to 675 LPM or water from 0.0002 ml/min to 20 LPM High-accuracy correlated flowmeters ±2% of reading! Excellent chemical

More information

Workhorse-15 Oxygen Generator

Workhorse-15 Oxygen Generator 11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse-15 Oxygen Generator Model No. 5719, 5727, 5735 for Domestic and International Units Part number 1432 Revision

More information

Model CS-1 Directional, Single Tone Urban/Inter-City Rail Air Horn

Model CS-1 Directional, Single Tone Urban/Inter-City Rail Air Horn Model CS-1 Directional, Urban/Inter-City Rail Ideal for urban/inter-city rail applications, horn can withstand harsh environmental conditions and high speed train vibrations. Single tone 311 Hz fundamental

More information

INSERT FITTINGS INSERT FITTINGS

INSERT FITTINGS INSERT FITTINGS Insert Tee Insert x Female Tee Insert Elbow Insert x Male Elbow Insert Coupling Insert x Male Adapter Insert x Female Adapter Insert Plug POLY and NYLON FITTINGS For use with Poly Tubing Fitting 1/2 3/4

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Techcon Systems TS1258 Pressure Pot

Techcon Systems TS1258 Pressure Pot Techcon Systems TS1258 Pressure Pot User Guide TABLE OF CONTENT 1. SAFETY. 3 1.1 Intended Use 3 1.2 Safety Precaution 3 2. CERTIFICATE OF COMFORMANCE 4 3. FEATURES. 5 4. SPECIFICATIONS 5 5. INSTALLATION

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS CBW SERIES RESIDENTIAL BACKWASH FILTER SYSTEMS MODELS: CBW1001 CBW1501 CBW2001 Installer, please leave with homeowner. Homeowner, retain for future reference. INSTR2805

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

TECHNICAL ACCESSORIES

TECHNICAL ACCESSORIES A.R.I. VALVES S-050P AIR PLASTIC RELEASE 16 BAR Automatic Component A.R.I patent, Rolling Seal Mechanism: Dramatically reduces the possibility of obstruction by debris. Discharges high air flow rates upto

More information

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN Important: Read all instructions and refer to local codes prior to installation. l Local soil conditions may require more gravel for drainage. l

More information

DESIGN AND PRE - INSTALLATION INFORMATION

DESIGN AND PRE - INSTALLATION INFORMATION DESIGN AND PRE - INSTALLATION INFORMATION Installation of valves should be in accordance with The Water Supply (Water Fittings) Regulations 1999 and BS6700:1997 Para. 2.2.4 KP Type Valves offer a flexible

More information

ACCESSORIES FOR LANCASTER PUMPS & WATER SYSTEMS INDEX

ACCESSORIES FOR LANCASTER PUMPS & WATER SYSTEMS INDEX PAGE 1 ACCESSORIES FOR LANCASTER PUMPS & WATER SYSTEMS INDEX ADAPTERS PAGE OFFSET CASING ADAPTER 2 PITLESS ADAPTER 2 ROPE ADAPTER 4 VENTURI MALE ADAPTER 2 AIR VALUME CONTROL AIR VALVES 2 CABLE SUBMERSIBLE

More information

Storage Systems and Accessories

Storage Systems and Accessories Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single

More information

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual STOP! Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

BS2000 MOTOR ELECTRONICS, INC. PROTECTION INSTRUCTION MANUAL. (407) Phone: Website:

BS2000 MOTOR ELECTRONICS, INC. PROTECTION INSTRUCTION MANUAL. (407) Phone: Website: BS2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Revision Date: 6-23-14 RECOMMENDED REPLACEMENT

More information

screw fittings - nickel plated brass series SC

screw fittings - nickel plated brass series SC screw fittings - nickel plated brass series SC SC SCC SC SC SC SC SC SCC SC SC SC SCC SC SC SC2C SC2 SC2 SC SC3 SC3 SC0 SC design screw fitting with swivel nut connection 1/"...1/2" optionally cylindrical

More information

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument

More information

Prestige Water Equipment Ltd.

Prestige Water Equipment Ltd. The Prestige range of water softeners complements the range of water pre-treatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed Quality Plastic Pipe Fittings Technical Data Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed Effective April 1, 2002 PIPE DIMENSIONS IPS-IRON PIPE SIZE Minimum

More information

Piece Weight. List Price. Basket Strainer-Plastic. Wash Tray Plug. TIP TOE Tub Drain. Shower Drain Grids

Piece Weight. List Price. Basket Strainer-Plastic. Wash Tray Plug. TIP TOE Tub Drain. Shower Drain Grids PLUMBING SPECIALTIES PS_1018 EFFECTIVE OCTOBER 1, 2018 (SUPERCEDES PS_0918) The issuance of this price list is not an offer to sell the goods listed herein at the prices stated. Bath Coupling Elbow 123-096

More information

FIRE PROTECTION PRODUCTS

FIRE PROTECTION PRODUCTS AGF Manufacturing Inc. FIRE PROTECTION PRODUCTS PRODUCT CATALOG CAT-AGF_V002 1/15 Reliability, Versatility, Code Compatibility AGF Product Catalog Table of Contents COLLECTa ndrain Auxiliary Drains Model

More information

CULLIGAN CSM SERIES WATER SOFTENER

CULLIGAN CSM SERIES WATER SOFTENER Cat. No. 01016370 Rev. F 02/24/14 DCO # 014223 Installation, Operating and Service Instructions CULLIGAN CSM SERIES WATER SOFTENER 2014 Culligan International Com pa ny Printed in USA Attention Culligan

More information

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual 30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

USE AND MAINTENANCE MANUAL V260

USE AND MAINTENANCE MANUAL V260 USE AND MAINTENANCE MANUAL V260 S.A.T.I.A. srl Società Italiana apparecchiatura trattamento acqua MAN0034 BOZZA Pag. 1 di 21 DOCUMENT REVISION REVISION NOTE DATE MAN0034 DRAFT S.A.T.I.A. srl Società Italiana

More information

User's Manual. MixRite TF 10. Edition 05.08

User's Manual. MixRite TF 10. Edition 05.08 User's Manual MixRite TF 10 Edition 05.08 1 Tefen MixRite TF 10 fertilizer and chemicals Injector Congratulations on your purchase of one of Tefen s high quality products. To get the best results from

More information

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL Prepared by CR Manning Edited by SC Woidtke Rev August 22, 2011 PRESSURIZED WATER VESSEL OPERATING MANUAL 1. Background 1.1 The Pressurized

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS 36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

The ultimate in water softening

The ultimate in water softening Calming troubled waters Metered Water Softener Specification MODEL: CALSOFT M The ultimate in water softening Due to Calmag s commitment to new product development the photographs contained within these

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

Product Catalogue. February We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping

Product Catalogue. February We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping Product Catalogue February 2019 PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping We mean progress. Table of contents Table of contents 1 Uponor Design Services

More information

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

TECHNICAL DATA. Dry 132a. October 1, 2008

TECHNICAL DATA. Dry 132a. October 1, 2008 October 1, 2008 Dry 132a 1. Description Viking High Pressure (HP) Dry Systems utilize a Viking Model E or Model F Deluge Valve to control the water supply to system piping equipped with closed sprinklers.

More information

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED

More information

Municipal Boost w/pre-treatment Monitoring System K-A-MCB-PRE

Municipal Boost w/pre-treatment Monitoring System K-A-MCB-PRE Operation Manual Municipal Boost w/pre-treatment Monitoring System K-A-MCB-PRE 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2

More information

Operation and Maintenance Manual for

Operation and Maintenance Manual for Operation and Maintenance Manual for KFZST KF Series Twin Softener Systems Catalog # Serial # USFilter 10 Technology Drive Lowell, Massachusetts 01851 Tel: (800) 875-7873 Fax: (978) 441-6025 Email: Lowell_TechSupport@USFilter.com

More information

Sanitizer Parts. Sanitizer Parts. Replacement Parts for Sanitizers

Sanitizer Parts. Sanitizer Parts. Replacement Parts for Sanitizers Sanitizer Parts for Sanitizers 513 Automatic Feeder Model 300, 302, 300-19, 300-29 Order No.: R171016 R171026 Model No.: 300 302 Description: AUTOMATIC FEEDER SPA HOT TUB FEEDER 1 1 R172008W 3 in. threaded

More information

INSTRUCTION MANUAL. Automatic Water Softener System. Model: PSE-08. Xsential Water Filtration Systems

INSTRUCTION MANUAL. Automatic Water Softener System. Model: PSE-08. Xsential Water Filtration Systems INSTRUCTION MANUAL Automatic Water Softener System Model: PSE-08 Xsential Water Filtration Systems 78 Daly Street Ascot Western Australia 6104 Ph: 1300 366 295 Fax: (08) 9277 2266 www.xsential.com.au Welcome

More information

Avenger Model 33M Installation & Operation Instructions

Avenger Model 33M Installation & Operation Instructions Avenger Model 33M Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737 Phone:

More information

BGC258 Series BASOTROL Gas Valve

BGC258 Series BASOTROL Gas Valve Installation Instructions BGC258 Issue Date September 6, 2017 BGC258 Series BASOTROL Gas Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing

More information

KRO AUGUST Prepared for: WashTec Australia 1, 33 Maddox Street Alexandria NSW 2015 Sydney, Australia

KRO AUGUST Prepared for: WashTec Australia 1, 33 Maddox Street Alexandria NSW 2015 Sydney, Australia KRO - 3000 AUGUST 2006 Prepared for: WashTec Australia 1, 33 Maddox Street Alexandria NSW 2015 Sydney, Australia Prepared by: Chatoyer Holdings Pty. Ltd. ABN: 99 080 301 515 www.chatoyer.com.au BRISBANE

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

Livewell/Baitwell Pumps. Livewell/Aerator

Livewell/Baitwell Pumps. Livewell/Aerator Livewell/Baitwell Pumps 03 Livewell/Baitwell Pumps Livewell/Aerator 049 050 03 Livewell / Baitwell Pumps selection GUIDE Livewell / Baitwell Pumps Tournament Series Bronze Base Fitting Discharge Outlet

More information

BARRICADE 286 AIRLINE FILTERS

BARRICADE 286 AIRLINE FILTERS BARRICADE 286 AIRLINE FILTERS PART NUMBERS AND SCHEMATICS GUIDE Company Profile Since 1944, Marco has developed a strong tradition of providing innovative and reliable products and services to the surface

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information