EN ISO/IEC Technical Requirements
|
|
- Candice Hill
- 6 years ago
- Views:
Transcription
1 EN ISO/IEC Technical Requirements Wolfgang Garche Environmental Protection Agency Department Air Quality Monitoring, Information, Assessment 1
2 What means accreditation in accordance to EN ISO/IEC Confirmation of competence of a testing or calibration laboratory by an independent third party, the accreditation body, to carry out specific tests and/or calibrations. Directive on ambient air quality and cleaner air for Europe Annex I C. Quality assurance for ambient air quality assessment, data validation To ensure accuracy of measurements and compliance with the data quality objectives, the appropriate competent authorities and bodies designated pursuant to Article 3 shall ensure: that the national laboratories, are accredited according to EN/ISO by 2010 for the reference methods referred to in Annex VI 2
3 Technical requirements 1. personnel 2. accommodation and environmental conditions 3. test and calibration methods and method validation 4. equipment 5. measurement traceability 6. reference standards and reference materials 7. handling of test and calibration items 8. assuring the quality of test and calibration items 3
4 1. Personnel appropriate staff (quantity and qualification) personnel training and education procedures for identifying training needs effectiveness of training actions shall be evaluated own personnel (employed by or under contract to the laboratory) authorization of specific personnel to perform specific types of sampling, tests or calibrations to issue test reports and calibration certificates to operate particular types of equipment 4
5 2. Accommodations and environmental conditions Laboratory facilities Monitoring the environmental conditions Tests and calibrations shall be stopped when the environmental conditions jeopardize the results of the tests and/or calibrations. Preventing cross-contamination Access to the laboratory Good housekeeping 5
6 3. Test and calibration methods and method validation Reference methods mentioned in Annex VI: EN 14212:2005 "Ambient air quality Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence EN 14211:2005 "Ambient air quality Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence EN 14902:2005 "Standard method for measurement of Pb/Cd/As/Ni in the PM10 fraction of suspended particulate matter" EN 12341:1999 "Air Quality Determination of the PM10 fraction of suspended particulate matter Reference method and field test procedure to demonstrate reference equivalence of measurement methods" EN 14907:2005 "Standard gravimetric measurement method for the determination of the PM2,5 mass fraction of suspended particulate matter" EN 14662:2005, parts 1, 2 and 3 "Ambient air quality Standard method for measurement of benzene concentrations" EN 14626:2005 "Ambient air quality Standard method for the measurement of the concentration of carbon monoxide by non-dispersive infrared spectroscopy" EN 14625:2005 "Ambient air quality Standard method for the measurement of the concentration of ozone by ultraviolet photometry" 6
7 Other needed methods and procedures for: the calibration of analysers and other test and measurement devices the certification of test gases (from cylinders or generators) the production of test gas mixtures (permeation, dilution, etc) (e.g. ISO Permeation method) A Member State may use any other method if it can be demonstrated that the results are equivalent to the reference method. Validation of applied methods and procedures Non-standard methods Laboratory designed/developed methods Standard methods used outside their intended scope Amplifications and modifications of standard methods 7
8 Estimation of uncertainty of measurements A calibration laboratory shall have and apply a procedure to estimate the uncertainty of measurements for all calibrations and types of calibration. (EN ISO Air quality Guidelines for estimating measurement uncertainty ENV Guide to the Expression of Uncertainty in Measurement (GUM) ) 8
9 4. Equipment Laboratory shall be furnished with all items of sampling, measurement and test equipment for the correct performance of the tests and/or calibrations (5.5.1). Equipment used for testing, calibration and sampling shall be capable of achieving the required accuracy and shall comply with the specifications relevant for the tests and/or calibrations concerned (5.5.2). Directive on ambient air quality and cleaner air for Europe All new equipment purchased for implementation of this Directive must comply with the reference method or equivalent by two years after the date of entry into force of this Directive. All equipment used in fixed measurements must comply with the reference method or equivalent by five years after the date of entry into force of this Directive 9
10 5. Measurement traceability If calibration is a dominant factor of the uncertainty budget the requirements of should be strictly followed ( ) The programme for calibration of equipment shall be designed and operate so as to ensure that calibrations and measurements are traceable to the International System of Units (SI) Directive on ambient air quality and cleaner air for Europe The appropriate competent authorities and bodies designated pursuant to Article 3 shall ensure: that all measurements undertaken in relation to the assessment of ambient air quality pursuant to Articles 6 and 9 are traceable in accordance with the requirements set out in Section of the ISO/IEC 17025:
11 Traceability can be established by means of an unbroken chain of calibrations or comparisons. The link to SI units may be achieved by reference to national standards. When using external calibration services, traceability shall be assured by the use of services from laboratories that can demonstrate competence, measurement capability and traceability. Calibration certificates shall contain the measurement results, including the measurement uncertainty and/or a statement of compliance with a identified meteorological specification. 11
12 6. Reference standards and reference materials Laboratory shall have a programme and procedure for the calibration of its reference standards (RS). RS shall be calibrated by a body that can provide traceability RS shall be used for calibrations only Reference materials shall be traceable to SI units or to certified reference materials (CRM) Internal reference materials shall be checked (if practicable) Intermediate checks are needed to maintain confidence in the calibration status of reference, primary, transfer or working standards and reference materials. Checks shall be carried out to defined procedures and schedules. (5.6.3) 12
13 7. Handling of test and calibration items Laboratory shall have procedures for the transportation, receipt, handling, protection, storage, retention and/or disposal of test and /or calibration items, including all provisions necessary to protect the integrity of the test or calibration item a system for identifying test and/or calibration items procedures and appropriate facilities for avoiding deterioration, loss or damage to the test or calibration items 13
14 8. Assuring the quality of test and calibration items Laboratory shall have quality control procedures for monitoring the validity of tests and calibrations. Resulting data shall be recorded in such a way that trends are detectable. Where practicable statistical methods shall be applied to the reviewing of the results. This monitoring shall be planned. The monitoring may include: regular use of certified reference material participation in interlaboratory comparisons or proficiency-testing programmes replicate tests or calibrations using the same or different methods Quality control data shall be analysed and, where they are found to be outside pre-defined criteria, planned actions shall be taken to correct the problem. 14
15 Scope of accreditation: reference methods specified in Annex VI calibration procedures for analysers, measurement and control facilities for volume flows, temperature and pressure sensors procedures for the preparation of test gas mixtures 15
16 Many Thanks for your Attention! 16
Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.
Bulletin Category: GAS Bulletin: G-23 Page: 1 of 7 The copy of this document located on Measurement Canada s website is considered to be the controlled copy. Recognition of data from specialty gas suppliers
More informationGUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES
GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES ESYD G-DIAKRIB/01/01/26-03-2015 1/6 ESYD G-DIAKRIB Issue: 01 Revision: 01 Issue Date: 28-11-2007
More informationGas mixtures. Individual solutions specifically for your application
Gas mixtures Individual solutions specifically for your application For many applications besides pure gases also defined gas mixtures are required. For many routine applications, from operating gases
More informationMaximum precision for quantifiable success.
Accredited calibration gas mixtures Maximum precision for quantifiable success. Reference materials and other accredited calibration gas mixtures. 02 Accredited calibration gas mixtures It s now official:
More informationMETROLOGICAL ASSURENCE OF O3, CO2, CH4 AND CO CONTROL IN ATMOSPHERE
METROLOGICAL ASSURENCE OF O3, CO2, CH4 AND CO CONTROL IN ATMOSPHERE Leonid A. Konopelko Yuri A. Kustikov Vitaly V. Beloborodov Dmitry N. Selukov D.I.Mendeleyev Institute for Metrology (VNIIM), 19 Moskovsky
More informationCALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)
CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE (+34) 968 162 005 www.sensovant.com comercial@sensovant.com www.epluse.com CALIBRATION AT THE HIGHEST LEVEL The
More informationDate of Shipment: Xxxxx 00, 20xx 3402c National Institute of Advanced Industrial Science and Technology National Metrology Institute of
Date of Shipment: Xxxxx 00, 20xx 3402c01151112-170831 National Metrology Institute of Japan Reference Material Certificate NMIJ CRM 3402-c01 Sulfur Dioxide This certified reference material (CRM) was produced
More informationCALIBRATION CERTIFICATE # 500
CALIBRATION CERTIFICATE # 5 Calibration date : -- Certificate issued : --8 Company name Company address City, Province, Canada CLAS 9- Calibration of Mass flow meter Brooks SLA585S S/N : ABCD QUALITY PROGRAM
More informationGas Metrology. SI-traceable: Primary Reference Materials Certified Reference Materials Calibrated Gas Mixtures Interlaboratory Comparisons
Gas Metrology SI-traceable: Primary Reference Materials Certified Reference Materials Calibrated Gas Mixtures Interlaboratory Comparisons T +31 15 2691500 E vsl@vsl.nl www.vsl.nl 1 This guide provides
More informationInterlaboratory comparison in the pressure range from 0 to 2 MPa for accredited calibration laboratories
Int. J. Metrol. Qual. Eng. 6, 307 (2015) c EDP Sciences 2015 DOI: 10.1051/ijmqe/2015021 Interlaboratory comparison in the pressure range from 0 to 2 MPa for accredited calibration laboratories Lovorka
More informationThe analysis of complex multicomponent
The analysis of complex multicomponent gas mixtures for emission monitoring 31 July 2017 Test and Measurement Prelly Marebane Fit-for-purpose reference materials for air pollution monitoring in SA and
More informationKeeping It Simple. Gas Mixtures for Stack Emissions Monitoring.
Keeping It Simple Gas Mixtures for Stack Emissions Monitoring www.uk.airliquide.com Stack Emissions Monitoring The Stack Emissions Monitoring market has undergone substantial legislative and quality changes
More informationGeneral European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT
General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (09) 64 R5 QUALIFICATION OF EQUIPMENT ANNEX 6: QUALIFICATION OF PISTON PIPETTES Full document title and reference Document type
More informationWhite Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:
Title: Comparison of Chemical Sensor and NDIR Technologies TSN Number: 25 File:\\MII- SRV1\Metron\Bridge_Analyzers\Customer_Service_Documentation\White_Papers\25_G en EGA NDIR vs Chemical Sensor.docx Created
More informationCertification of AMS acc. EN 15267, Part 3 - Overview and First Experience -
Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience - Dr. Wolfgang Jockel, Martin Schneider, TÜV Rheinland Group, D-51105 Cologne / Germany 1. Introduction A new basis for the certification
More informationRecommended Practices for Calibration Laboratories
Recommended Practices for Calibration Laboratories May 1999 General This document recommends environmental practices and documentary and operational protocols for calibration laboratories that provide
More informationCOAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE
COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE Peter Mason Manager, Coal Mines Technical Services, a division of Mines Rescue Pty Ltd, Australia ABSTRACT The NSW Mines Rescue
More informationStability and traceability of calibration gases for EN 14181
Stability and traceability of calibration gases for EN 14181 Stephen Mellor Especialista de Produto Product Specialist Analytical, Air Products Plc, United Kingdom DOSSIER EMISSÕES E MONITORIZAÇÃO ESTABILIDADE
More informationENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS
XIX IMEKO World Congress Fundamental and Applied Metrology September 6, 9, Lisbon, Portugal ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS Ana Madeira, Florbela A. Dias and Eduarda Filipe 3 Instituto Português
More informationCOOMET TECHNICAL COMMITTEE 1.8 PHYSICAL CHEMISTRY
COOMET TECHNICAL COMMITTEE 1.8 PHYSICAL CHEMISTRY CООМЕТ PROJECT 664/RU/14 SUPPLEMENTARY COMPARISON OF STANDARD GAS MIXTURES: «Atmospheric air pollutants: CO in Nitrogen, 5 µmol/mol - Technical Protocol,
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 6974-4 First edition 2000-04-01 Natural gas Determination of composition with defined uncertainty by gas chromatography Part 4: Determination of nitrogen, carbon dioxide and
More informationControls and Control Charting
Controls and Control Charting Control Charts and Trend Analysis for ISO/IEC 17025:2005 www.aphl.org Abbreviation and Acronyms CRM-Certified Reference Materials RM-Reference Materials PT-Proficiency Test(ing)
More informationSpeciality Gases Practice 4. Our quality, your safety. Accredited Test and Calibration Laboratory Speciality Gases Centre in Hörstel.
Speciality Gases Practice 4 Our quality, your safety. Accredited Test and Calibration Laboratory Speciality Gases Centre in Hörstel. Accredited Westfalen quality. Speciality Gases Centre in Hörstel. They
More informationResearch and Development. Money in the Pipeline
On-line gas chromatography Gerard Nieuwenkamp Research and Development Money in the Pipeline Delft, 2 November 2010 Natural gas metering 2" 2" 65 m3/h usm 6" 400 m3/h M etering runs 2500 m3/h Gas Oil Piston
More informationCALIBRATION. empanelled laboratories following standard procedures and using certified reference standards.
CALIBRATION A. Calibration of Air Analysers Gaseous Parameter a. The instruments/ analysers for real time monitoring of gaseous emissions shall be calibrated with respect to their functioning, drift, linearity
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 FLUKE CALIBRATION, PHOENIX PRIMARY PRESSURE AND FLOW LABORATORY 4765 East Beautiful Lane Phoenix, AZ 85044 Mike DiGioia Phone: 602 773
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 FLUKE CALIBRATION, PHOENIX PRIMARY PRESSURE AND FLOW LABORATORY 4765 East Beautiful Lane Phoenix, AZ 85044 Mike DiGioia Phone: 602 773
More informationAccreditation for In-Service Inspection of Transportable Pressure Receptacles (TPRs)
RG 3 Edition 4 December 2018 Accreditation for In-Service Inspection of Transportable Pressure Receptacles (TPRs) RG 3 / Edition: 4 Page 1 of 8 Contents 1. Introduction 2 2. Scope - Inspection Services
More informationCALIBRATION SYSTEM REQUIREMENTS. ESCC Basic Specification No
Page 1 of 8 CALIBRATION SYSTEM REQUIREMENTS ESCC Basic Specification Issue 4 February 2014 Document Custodian: European Space Agency see https://escies.org PAGE 2 LEGAL DISCLAIMER AND COPYRIGHT European
More informationTraceable calibration of automatic weighing instruments in dynamic operation
Traceable calibration of automatic weighing instruments in dynamic operation Matej Grum* Metrology Institute of the Republic of Slovenia, Grudnovo nabrežje 17, 1000 Ljubljana, Slovenia Abstract. The article
More informationProtocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO. Quality Assurance Plan/Standard Operating Procedure
Page 1 of 4 Protocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO Quality Assurance Plan/Standard Operating Procedure Page 2 of 4 Table of Contents 2.3.6 Protocol Gas
More informationImproved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL
Improved Reliability in Natural Gas Energy Measurement with the Revised ISO 10723 Standard Gerard Nieuwenkamp - VSL Improved reliability in natural gas energy measurement with the revised ISO 10723 standard
More informationRadon Chamber Accreditation Policy. 1.0 Introduction
Page 1 of 16 1.0 Introduction To assess the radon exposure of the general public and to effectively support a measurement quality assurance plan, the reliability and comparability of radon measurement
More informationRequirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)
Institut fédéral de métrologie METAS METAS-N001/EN Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T (15 000 G) This document is a translation
More informationPerformance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH
Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH 1 D-K-15143-01-00 Services around the measurement technology in Germanys most accurate DAkkS laboratory*. Whether
More informationGas Mixture Two Components. Gas Mixtures Two Components
Gas Mixture Two Components Two Components Contents Two-Component Mixtures Ammonia...M4 Argon...M5 Benzene...M6 n-butane...m7 Carbon Dioxide...M8 Carbon Monoxide...M10 Chlorine...M12 Ethane...M13 Ethylene
More informationSpecific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities
Specific Accreditation Criteria Calibration ISO IEC 17025 Annex Mass and related quantities January 2018 Copyright National Association of Testing Authorities, Australia 2014 This publication is protected
More informationMETHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)
METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE) 1.0 Scope and Application What is Method 3A? Method 3A is a
More informationMET-101 Introduction to Metrology
Pasig city Tel: 654-13-42 MET-101 Introduction to Metrology This 2-day course offers a basic introduction into Metrology, meant for people who are working in calibration and testing labs, maintenance services
More informationCertified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS
Certified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS Regular verification of laboratory instrumentation is of primary importance in a modern manufacturing facility, not only for reasons of
More informationKENYA ACCREDITATION SERVICE
KENAS-GUD-016 01 16/03/2013 16 / 04/2013 GUD Page 1 of 18 Approval and Authorisation Completion of the following signature blocks signifies the review and approval of this Document. Name Job Title / Role
More informationPROTOCOL FOR COMPRESSED AIR PROFICIENCY TESTING (CAPT) PROGRAM SAMPLE ANALYSIS
Contact Information: PROTOCOL FOR COMPRESSED AIR PROFICIENCY TESTING (CAPT) PROGRAM SAMPLE ANALYSIS No formal enrollment is required to participate in the CAPT program. To get added to the email notifications
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LAWRENCE FACTOR, INC. X-ZAM LAB SERVICES 4740 NW 157 th Street Miami Lakes, FL 33014 Lawrence Kaplan Phone: 305 430 0550 CHEMICAL Valid To: July 31, 2018 Certificate
More informationAGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY
AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY Agilent Vacuum Products: Our Committment to Quality Agilent s commitment to quality and Measurement s philosophy Reference Standards (PNEUROP, ISO)
More informationProtocol Gas Verification Program (PGVP)
Protocol Gas Verification Program (PGVP) Michael Hayes ICAC/ MARAMA Workshop Advances in Control Technologies July 9-10, 2008 Exton, PA PGVP Protocol Gases from an historic perspective Historical Audit
More informationGMC-I Service GmbH Calibration Center
2016 GMC-I Service GmbH Calibration Center DAkkS, ISO & Factorycalibration www.gmci-service.com From spare parts, reparation, rental service, maintenance of industrial health and safety standards, calibration
More informationGeneral Accreditation Criteria Reference Material Producers. ISO Standard Application Document
General Accreditation Criteria Reference Material Producers ISO 17034 Standard Application Document January 2018 Copyright National Association of Testing Authorities, Australia 2014 This publication is
More informationANSI / ASSE Z88.2 American National Standard Practices for Respiratory Protection (1992 rev. versus 2015 rev.)
ANSI / ASSE Z88.2 BACKGROUND: A substantial body of research has been published since the 1992 revision of Z88.2. This information related to the proper use and performance of respiratory protection in
More informationCOOMET TECHNICAL COMMITTEE 1.8 PHYSICAL CHEMISTRY. CООМЕТ project 576/RU/12
COOMET TECHNICAL COMMITTEE 1.8 PHYSICAL CHEMISTRY CООМЕТ project 576/RU/12 SUPPLEMENTARY COMPARISON STANDARDS IN THE FIELD OF ANALYSIS OF GAS MIXTURES CONTAINING СО 2, СО, С 3 Н 8 IN NITROGEN ( AUTOMOTIVE
More informationCERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Antibus Scales & Systems, Inc. 1919 Research
More informationPressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"
F. INTERPRETATION OF THE ESSENTIAL SAFETY REQUIREMENTS ON MANUFACTURING Guideline F-01 Guideline related to: Annex 1 Section 3.1.2 According to section 3.1.2 (permanent joining) of Annex I, the third party
More informationISO INTERNATIONAL STANDARD. Ambient air Determination of sulfur dioxide Ultraviolet fluorescence method
INTERNATIONAL STANDARD ISO 10498 First edition 2004-06-01 Ambient air Determination of sulfur dioxide Ultraviolet fluorescence method Air ambiant Dosage du dioxyde de soufre Méthode par fluorescence dans
More informationField verification of on-line HC dew point measurements
Field verification of on-line HC dew point measurements Andy Benton, Technical Consultant, Michell Instruments Limited, Ely, UK andy.benton@michell.com www.michell.com Introduction: The Michell Condumax
More informationLight Lab. Reliable Measurements through Regular Calibration. DAkkS
Light Lab Reliable Measurements through Regular Calibration QM DAkkS ARS 85 EYREIENCEG QM EXP Benefits of Calibration PERFECTION THROUGH CALIBRATION RIN EASU HT M OLOGY IG L IN ECHN T LEGAL CERTAINTY Avoidance
More informationTG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION
GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION Approved By: Senior Manager: Mpho Phaloane Revised By: Field Manager: Neville Tayler Date of Approval: 2015-08-26 Date of Implementation: 2015-08-26
More informationISO Vacuum gauges Calibration by direct comparison with a reference gauge
INTERNATIONAL STANDARD ISO 3567 First edition 2011-12-15 Vacuum gauges Calibration by direct comparison with a reference gauge Manomètres Étalonnage par comparaison directe avec un manomètre de référence
More informationFlare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1
Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost HERMAN HOLM SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 4C CONFERENCE APRIL 2018 SAN ANTONIO, TX SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC
More informationTEXAS DEPARTMENT OF PUBLIC SAFETY Breath Alcohol Laboratory
TEXAS DEPARTMENT OF PUBLIC SAFETY Breath Alcohol Laboratory 5805 N LAMAR BLVD BOX 4087 AUSTIN, TEXAS 78773 512/424-5200 STEVEN C. McCRAW DIRECTOR DAVID G. BAKER CHERYL MacBRIDE DEPUTY DIRECTORS January
More informationService ISO17025 explained
ABB MEASUREMENT & ANALYTICS ARTICLE Service ISO17025 explained The ISO17025 standard covers any organization offering testing and calibration services Measurement made easy Accredited laboratory for testing
More informationEPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards
EPA 600/R-12/531 May 2012 www.epa.gov/ord EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards Office of Research and Development National Risk Management Research Laboratory
More informationMETHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER
1250 METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1.0 Scope and Application. 1.1 Analytes. Analyte CAS No. Sensitivity Total Organic Compounds N/A
More informationCORESTA RECOMMENDED METHOD N 6
CORESTA RECOMMENDED METHOD N 6 DETERMINATION OF VENTILATION DEFINITIONS AND MEASUREMENT PRINCIPLES (2015 Revision September 2016) 1. SCOPE This CORESTA Recommended Method specifies a method for the determination
More informationPharmaceutical Grade Nitrogen & Gardner Denver / CompAir PSA Nitrogen Gas Generation Systems
Pharmaceutical Grade Nitrogen & Gardner Denver / CompAir PSA Nitrogen Gas Generation Systems The purpose of this document is to clarify the specification for pharmaceutical grade nitrogen gas and confirm
More informationSystems of Accounting for and Control of Nuclear Material
Systems of Accounting for and Control of Nuclear Material STATES' OBLIGATIONS TO ESTABLISH AN ACCOUNTING AND CONTROL SYSTEM The implementation of safeguards agreements has always involved governmental
More informationISO/TR TECHNICAL REPORT. Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation)
TECHNICAL REPORT ISO/TR 12148 First edition 2009-02-15 Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation) Gaz naturel Étalonnage des instruments du type
More informationMr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA
Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA Dear Roger, Your Ref: Our Ref: Direct Dial: 020 7901 7468 Email:
More informationMedical gases and mixture. New horizons for human health
Medical gases and mixture. New horizons for human health Medical gases as drugs Among the new frontiers of medicine, medical gases represent a resource of interest in the fight against human diseases.
More informationTitle: INSTRUMENT AND EQUIPMENT DOCUMENTATION AND RECORDS
Page 1 of 7 Sections Included in this Document and Document History 1. Purpose 2. Scope 3. Responsibilities 4. Background 5. References/(Deleted date) 6. Procedure 7. Definitions 8. Records 9. Supporting
More informationIMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS
CODE OF PRACTICE 42 IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS REVISION 1 : 2014 CODE OF PRACTICE 42 IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS REVISION 1: 2014 Copyright 2014 by British Compressed
More information20. Technical Equipment. Archived. This section applies to all equipment used in forensic examinations, such as
Instruments and Equipment Introduction 5.5. Authorization to use technical equipment 5.5.3 Use of instruments and equipment Instruction and maintenance manuals 5.4. 5.5.3 Use of nonlaboratory equipment
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationHazard Communication Program
The University of Memphis Hazard Communication Program November 2016 Table of Contents University of Memphis Hazard Communication Program Contents Purpose... 1 Scope and Application... 1 Responsibilities...
More informationAPPENDIX C. 40 CFR PART 60 App. B SPEC. 1-4, 6
APPENDIX C 40 CFR PART 60 App. B SPEC. 1-4, 6 Part 60, Appendix B - Performance Specification 2 Specifications and Test Procedures for SO2 and NOx Continuous Emission Monitoring Systems in Stationary Sources
More informationTitle: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)
Procedure No: SOP-025 Revision No: 1.0 (January 21, 2011) Page No.: 1 of 8 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to
More informationEmergency Medical Services Agency Public Safety AED Service Provider Guide
Emergency Medical Services Agency Public Safety AED Service Provider Guide 2180 Johnson Ave., 2 nd Floor San Luis Obispo, CA 93401 805-788-2511 Phone 805-788-2517 Fax www.sloemsa.org PUBLIC SAFETY AED
More informationNMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013
NMISA NEW GAS FLOW CALIBRATION FACILITY Deona Jonker 7 October 2013 Introduction Flow the total volume of a fluid that flows past a fixed point in a given time Flow measurements used in industry as a means
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD First edition 1990-09-0 1 Ambient air - Determination of the mass concentration of Sulfur dioxide - Tetrachloromercurate (TCM)/pararosaniline Air ambiant - Determination de la concentration
More informationQUALITY ASSURANCE SPECIFICATION NONDESTRUCTIVE EXAMINATION PAGE 1 OF 7
QUALITY ASSURANCE SPECIFICATION REVISION: 0 DATE: 08/29/14 NONDESTRUCTIVE EXAMINATION PAGE 1 OF 7 1.0 Purpose The purpose of this specification is to establish the minimum quality assurance requirements
More informationGuidelines for Real Time Sampling & Analyses
Guidelines for the Measurement of Ambient Air Pollutants VOLUME-II Guidelines for Real Time Sampling & Analyses CENTRAL POLLUTION CONTROL BOARD (Ministry of Environment & Forests, Govt. of India) Parivesh
More informationBalancing and Settlement Code. Code of Practice Four
Balancing and Settlement Code Code of Practice Four CODE OF PRACTICE FOR THE CALIBRATION, TESTING AND COMMISSIONING REQUIREMENTS OF METERING EQUIPMENT FOR SETTLEMENT PURPOSES Issue 6 Version 11.0 Date:
More informationSKSTEX36(SQA Unit Code-H7C9 04) Calibrate textile production equipment
Overview This standard is for those who carry out routine calibrations at prescribed intervals in order to keep equipment in calibration. The job role will involve: 1. Performing calibration 2. Identifying
More informationFlexible hoses - Non-metallic materials
CLASS PROGRAMME Type approval DNVGL-CP-0183 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationUKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide
ABB MEASUREMENT & ANALYTICS PRODUCT GUIDE PG/SMD140 EN REV. B UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide Measurement made easy UKAS calibration laboratory
More informationINDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents
1 of 9 1.0 Purpose & Scope 2.0 Responsibilities 3.0 Definitions 4.0 Prerequisites 5.0 Precautions 6.0 Procedure 7.0 Implementation And Training 8.0 References 9.0 Attachments 10.0 Documentation Contents
More informationEast Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C EXPIRATION DATE: June 30, 2015
November 14, 2014 East Building, PHH-30 U.S. Department 1200 New Jersey Avenue S.E. of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 16219 EXPIRATION
More informationIII Code. TRACECA Maritime Safety and Security IMSAS workshop Kiev (Ukraine) III Code. Dr. Jens U. Schröder-Hinrichs
III Code III Code III Code TRACECA Maritime Safety and Security IMSAS workshop Kiev (Ukraine) Dr. Jens U. Schröder-Hinrichs IMSAS workshop Kiev Agenda 1 2 3 4 5 6 7 8 9 Introduction Background to IMSAS
More informationSTANDARD OPERATING PROCEDURES
PAGE: 1 of 14 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 5.1 Subatmospheric
More informationThis test shall be carried out on all vehicles equipped with open type traction batteries.
5.4. Determination of hydrogen emissions page 1 RESS-6-15 5.4.1. This test shall be carried out on all vehicles equipped with open type traction batteries. 5.4.2. The test shall be conducted following
More informationROLE DESCRIPTIONS BY COMPETENCY LEVEL
UNIVERSITY OF NORTH CAROLINA WILMINGTON Scientific Diving Specialist DESCRIPTION OF WORK: These positions execute research protocols in accordance with input from scientists or members of the mission team.
More informationCompiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.
1. Scope Description of requirements and procedures for compact provers to be used as verification standards. 2. Reference documents Trade Metrology Act SANS1698 3. Policy A. BASIC REQUIREMENTS Compact
More informationIndustry Consultation Paper
Industry Consultation Paper Proposed amendments to the European Communities (Carriage of Dangerous Goods by Road and Use of Transportable Pressure Equipment) Regulations 2011 to 2015 concerning Pressure
More informationMeasurable results. Primary and Secondary Standard Calibration Service
Measurable results. Primary and Secondary Standard Calibration Service If it measures flow, we can calibrate it. Among the world s elite flow calibration facilities, Badger Meter Flow Dynamics primary
More informationFinal Report of APMP.QM-K46 Ammonia in Nitrogen at 30 µmol/mol Level
Final Report of APMP.QM-K46 Ammonia in Nitrogen at 30 µmol/mol Level Shinji Uehara 1), HAN Qiao 2), Takuya Shimosaka 3)* 1) Chemicals Evaluation and Research Institute, Japan (CERI) 2) National Institute
More informationCommercial Practice Test Method Internal Vapor Analysis of Hermetic Devices
Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices Oneida Research Services, Inc. 8282 Halsey Road Whitesboro, NY 13492 Phone: (315) 736-5480 FAX: (315) 736-9321 1.0 Purpose The
More informationat NIST: ultra-low outgassing rates
Traceable outgassing measurements at NIST: ultra-low outgassing rates and new materials James Fedchak Thermodynamic Metrology Group Sensor Science Division Physical Measurement Laboratory Vacuum Project:
More informationDepartment of the Interior Departmental Manual
Department of the Interior Departmental Manual Effective Date: 3/12/99 Series: Safety Management Part 485: Safety and Occupational Health Program Chapter 27: Underwater Diving Safety Originating Office:
More informationVaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.
Asset #: 123 Calibration - Certificate No: 2083.01 Customer: Condition: Action Taken: Sample Inc. 123 Sample Rd. Sample, MA 01234 The instrument was operational upon receipt. The instrument was adjusted
More informationPORTS AUSTRALIA. PRINCIPLES FOR GATHERING AND PROCESSING HYDROGRAPHIC INFORMATION IN AUSTRALIAN PORTS (Version 1.5 November 2012)
PORTS AUSTRALIA PRINCIPLES FOR GATHERING AND PROCESSING HYDROGRAPHIC INFORMATION IN AUSTRALIAN PORTS (Version 1.5 November 2012) PREFACE These Principles have been prepared by the Hydrographic Surveyors
More informationSTD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015
page 1 of 6 TNI Standard EL-V1M4 Sections 1.7.1 and 1.7.2 September 2015 Description This TNI Standard has been taken through all of the voting stages and has received consensus approval by the TNI membership.
More informationCalibration and Bump Test Requirements for Direct Reading Portable Gas Monitors
: Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors Manufacturers and regulatory agencies agree the safest and most conservative approach is to perform a functional test by
More information