AUTOMATIC IRON REMOVAL FILTERS: FFD/D
|
|
- Gwen Jacobs
- 6 years ago
- Views:
Transcription
1 AUTOMATIC IRON REMOVAL FILTERS: INSTRUCTIONS MANUAL WARNING! The equipment must be used only for the utilization for which they have been designed, as shown in the technical documentation. Read carefully this leaflet until the end before starting any operation. Proceed strictly according to all directions included in this manual. Automatic iron removal filters series are designed to treat raw water supplied from municipalities or from well. ANY OTHER APPLICATIONS OF THE EQUIPMENT DIFFERENT THAN THE MENTIONED ONES IS MADE UNDER THE ONLY RESPONSIBILITY OF THE USER. For any assistance concerning the installations, maintenance or utilization of the equipment apply the NOBEL Service Center closest to you or directly: NOBEL S.r.l. tel fax rel. 0 Page 1 of 14 ffd_mi-r0.doc
2 INDICE 1. Safety CE mark, declaration of conformity How to displace the unit Hydraulics Electrical How to store, delivery and install Principles of working Technical characteristics Assumed raw water characteristics Technical characteristics (general) Characteristics for each model Dimensions Weight Installation How to remove packaging How to move and lift the unit Placing & commissioning Hydraulic connections Electric wiring connections End cycle & regeneration End cycle Regeneration How to set the time of phases Starting-up Service & maintenance Disposal Main components Trouble shooting guide...14 Annex: SCHEME1: dimensions SCHEME 2: components models FFD04, FFD06 SCHEME 3: components models FFD08 FFD40 SCHEME 4: installation models FFD04, FFD06 SCHEME 5: installazione modelli FFD08 FFD40 Special instructions membrane valves Special instructions programmer Declaration of conformity s.r.l. - ITALY Page 2 of 14 ffd_mi-r0.doc-r0
3 1. Safety 1.1. CE mark, declaration of conformity The equipment is designed to meet state-of-the-art safety requirements, has been tested and left the factory in a condition in which it is safe to operate. The equipment complies with the applicable standards and regulations as listed in the CE declaration of conformity and thus complies with the statutory requirements of the CE Directives. NOBEL confirms the successful testing of the equipment by sticking to it the CE mark How to displace the unit Particular care and attention should be put in during moving and displacing of heavy items, in order to avoid injuries to persons or damages to properties. The heavy parts must be lifted and displaced always hooking and lifting them by the points shown on the drawings (see fig. 1) and using only suitable ropes, hooks and/or chains, according to the weight (see Table of Weights) Hydraulics All operations must be performed by and/or under direct supervision of skilled and authorized operators, using proper tools and personal protection devices, if required (CE marked). Before any operation of taking out pipes or part of hydraulic system, it is required to release the pressure inside and empty the part of the system Electrical Before starting any operation on electrical devices, be sure that main power supply is OFF. All operations must be performed by skilled and authorized operators. In case of liquid leakage, switch off the main power supply before operate. Before the switching ON, be sure all the parts of the system are perfectly dry. Check that the available electrical power is correct (see 3.2 page 5) before connection How to store, delivery and install t = ºC t = ºF humidity rel. notes closed rooms % without condensate open space % without condensate protect from sun-light and rain. transport % without condensate protect from sun-light and rain. installation % without condensate protect from sun-light and rain. s.r.l. - ITALY Page 3 of 14 ffd_mi-r0.doc-r0
4 2. Principles of working Iron removal filters series FFD are used for water treatment for residential and industrial applications as well. All the materials, media filter included, are food grade and approved for drinking water. The range of models includes systems with capacity from 4.0 up to 40.0 m³/h. Iron removing is the process of filtration that allows to remove iron and manganese from water. This special filtration is made through a special catalytic media filter, (activated pyrolusite, briefly successively named PL, mixed with quartz-sand) which action is to oxide and then filter the dissolved iron and manganese. The media filter is kept in its activated state by mean of an oxiding agent, oxigen or hypochlorite, contained in water. As a general rule, the continuous addiction of sodium hypochlorite in water, upstream of the filter, is used; this system is more reliable and effective than the forced oxygenation. Under the same conditions of the filtering bed, the filtration action increases when the linear flow (speed of water trough the media) decreases, hence at a lower flow rates. The slower is the linear flow, the better is the filtration action. During the process, as the filtering bed traps the suspended particles, as filtration action increases, since the trapped solids works the same way of a filtering bed! But it also increases the resistance of the filtering bed against the water flow; so the pressure drop between inlet and outlet increases as well. The maximum allowed pressure drop is 1 bar (100 kpa), afterthat it is required to backwash the filtering bed. The purpose of the backwashing is to re-built the filtering bed efficiency, by removing the solids trapped during service; it is featured by a counter-flow of water through the filtering bed. The working of the system is controlled by an automatic programmer, allowing to schedule the day and the hour of the regeneration (backwashing). For the best working of the filter, the backwashing should be featured before the pressure drop reaches the threshold level (1 bar kpa). According to that, it is suggested to schedule the regeneration according to a pressure drop of bar (60 70 kpa). During regeneration the supplying of water is shut-off by mean of a membrane valve installed along the outlet line of the equipment. s.r.l. - ITALY Page 4 of 14 ffd_mi-r0.doc-r0
5 3. Technical characteristics 3.1. Assumed raw water characteristics temperature min max ºC (ºF) 5 40 (41 104) minimum pressure bar (kpa) 1,5 (150) Fe or Mn content in inlet water ppm 3,0 ph inlet water 6,5 8,5 residual active chlorine ppm Cl 0,4 0, Technical characteristics (general) power supply V ph/hz W 230 1/50 10 regeneration time min Δp min/max bar (kpa) 0,2 1,0 (20 100) 3.3. Characteristics for each model MODEL maximum backwashing water connections flow m³/h pressure consumption bar (kpa) IN/OUT Ø drain Ø operating 1) max 1) backwash 2) liters FFD 04 8,0 (800) 1¼" 1" 2,0 4,0 5, FFD 06 8,0 (800) 1½" 1¼" 3,0 6,0 7, FFD 08 8,0 (800) 1½" 1¼" 4,0 8,0 10, FFD 10 8,0 (800) 1½" 1½" 5,0 10,0 12, FFD 13 8,0 (800) 2" 1½" 6,5 13,0 16, FFD 15 8,0 (800) 2" 2" 7,5 15,0 18, FFD 19 8,0 (800) 2½" 2½" 9,5 19,0 23, FFD 23 8,0 (800) 2½" 2½" 11,5 23,0 28, FFD 30 8,0 (800) DN80 2½" 15,0 30,0 37, FFD 35 6,0 (600) DN80 2½" 17,5 35,0 43, FFD 40 6,0 (600) DN100 DN ,0 50, ) As mentioned, under the same conditions of the filtering bed, the filtration action increases when the linear flow (speed of water trough the media) decreases, hence at a lower flow rates. The values of flow rate listed under operating are the ones assuring the best effectiveness and longest wear of the filtering bed, according to characteristics of raw water close to the limits mentioned at above 3.1. According to the real conditions of working (continuous service, constant flow rate, etc) and the chemical-phisical characteristcs of raw water, the service flow rates can be increased up to values mentioned under max. 2) The mentioned backwashing flow rate should never be overpassed; higher flow rate could separate the mixed media PL / quartz-sand. s.r.l. - ITALY Page 5 of 14 ffd_mi-r0.doc-r0
6 3.4. Dimensions See DRAWING 2 installation & dimensions 3.5. Weight MODEL vessel quartz-sand kg PL shipping on service kg 2-3 mm mm kg approx. kg approx. kg FFD FFD FFD FFD FFD FFD FFD FFD FFD FFD FFD s.r.l. - ITALY Page 6 of 14 ffd_mi-r0.doc-r0
7 4. Installation 4.1. How to remove packaging The vessels are usually shipped wrapped in a polyethilene foil; remove it carefully before the starting up. Keep the cards and everything contained inside the packaging. The media filter are shipped as separated, in bags of 25 kg each How to move and lift the unit The vessel can be displaced when it is empty, hooking and lifting by the special rings mounted on the upper part of the vessel (see fig. 1). It is recommended to use proper sized hooks and ropes, according to the weight. It is also possible to hook and lift the vessel by the bearing legs. GOLFARI HOOKING CAUTION : DO NOT LIFT OR MOVE THE UNIT HOOKING OR CATCHING BY THE PRE-ASSEMBLED PARTS GAMBE DI SOSTEGNO LEGS Figura Placing & commissioning Place the column of media filter on a perfectly flat surface. See the dimensional drawing concerning the placing of the unit according to the walls of the site and required room for maintenance and service. The shown scheme is only suggested; the column can be placed in different positions; according to the inlet/outlet connections on the valve groups. Load the supplied quartz-sand 2-3 mm into the vessel, through the lower man-hole, until the sand covers completely the filter-nozzles. Make a flat surface of the sand using a wooden tool, in order to avoid any damage to the coating of the vessel. Close the man-hole tightening the nuts. Proceed in loading the rest of the media, through the upper man-hole (or through the upper head, see components drawing), shipped separately. Before loading check that the available quantity comply with the table of weights. The media filter must be loaded alternating three bags of quartz-sand mm and two bags of PL, until all the supplied media have been loaded. NB: The alternating loading is required in order to mix the two kind of media (quartzsand and PL) supplied; the mixing will be properly completed by featuring the first backwashing. After completed the loading, close the upper man-hole (or upper head) Fix the valves manifold to the vessel (see installation drawing) Fix the control board to the valves manifold. s.r.l. - ITALY Page 7 of 14 ffd_mi-r0.doc-r0
8 4.4. Hydraulic connections (see installation and components drawings) In order to avoid shut-off during maintenance operations, an emergency by-pass line should be provided. Complete the line from inlet fittings to the raw water line. Complete the line from outlet fittings (valves no. 2) to the treated water line. Connect the drain valves (nos. 1 and 6) of each column to a floor drain. The gate valve mounted downstream of the valve no. 6 will be used to adjust the backwash flow rate. A common flexible pipe made in plastic or rubber can be used for the drain line; its diameter must be of at least one size larger of the one mentioned on CHARACTERISTICS FOR EACH MODEL table. It is suggested the drain line could be inspected in order to check quantity and quality of drain water, as well as any leakage of media filter from the unit. Connect the inlet air fitting, placed on the base manifold of the solenoid valves, to a compressed air-mains, complete with pressure reducer, dehumidifier filter and shut-off valve. The air pressure must be kept at value equal or higher of the pressure of water to be treated, with max value of 8.0 bar. Whether water is used to pilot the valves, the inlet fitting of the base manifold of the solenoid valves must be connected to the pilot water fitting (¼"), pre-arranged on the inlet manifold of column; run to the drain a pipe from the drain fitting (¼") of the base manifold of the solenoid valves. Complete the line between the outlet fitting of each solenoid valve to the correspondent membrane valve : PILOT SOLENOID VALVE MEMBRANE VALVE EV n. Type n. Type 1 NC V1 NC 2 NC V2 NO 3 NC V3-V4-V5 NC-NO-NC All the solenoid valves can be hand-driven by the lever placed at the base of each of them; the turning of the lever simulate the action of the coil. Then, for valves NC type, the valve is closed when the lever is on parallel to the base; it is opened when the lever is on perpendicular to the base itself. s.r.l. - ITALY Page 8 of 14 ffd_mi-r0.doc-r0
9 4.5. Electric wiring connections Connect the power cable of the programmer to a power socket check that the available power is correct as listed in technical characteristics ( 3.2). The relais R, available upon request, allows to have a free voltage contact for remote segnalation of running regeneration; the wiring connection must be made directly on the clamps of NO contact on the relais itself. s.r.l. - ITALY Page 9 of 14 ffd_mi-r0.doc-r0
10 5. End cycle & regeneration 5.1. End cycle The adjustment of the end cycle depends on the quantity of iron, manganese and suspended solids the water contains. Take note of the parameters to be taken in consideration, as below listed, since a correct adjustment can be made only checking the real operating conditions. The end of a cycle is reached when the pressure drop across the filter is approx bar ( kpa). After checked after how long time the max allowable pressure drop is reached, it is possible to adjust the time schedule of the regeneration definitely. The filters are equipped with an electronic time programmer that allows to schedule the automatic regeneration: it starts at selected time and day (24 h, 7 days) Regeneration The regeneration is automatically controlled; it can also be started manually, at any time. The manual start of a regeneration can be made by a proper sequence of pushing the buttons 1 and 2 placed on the programmer, in order to act the relays of the channels 1 and 2. During the operation, the power must be ON. When the regeneration, manually started, is completed, the unit will continue to work according to the pre-set schedule. The regeneration can also run in case of power failure, by hand-driving the lever of the pilot solenoid valves: the solenoid valve is closed when the lever is on parallel to the base and it is open when it is on perpendicular to the base itself. Naturally, the compressed air supplying (air controlled valves) or pilot water supplying (water controlled valves) must be assured. The correspondent membrane valves (controlled by the pilot solenoid ones), if NC type is open when the solenoid valve is open, and viceversa if the membrane valve is NO type. PHASE SOLENOID VALVES OPEN VALVES EXCITED (=OPEN) SERVICE // V2 - V4 BACKWASHING E2 - E3 V3 - V5 RINSE E1 - E2 V1 - V4 The regeneration phases run one after another, as follows : 1. Backwash : during this phase, the water flushes from the bottom to the top of the column, lifting the filtering media and releasing the solids trapped on its surface during the service. The backwashing water flows to drain from the top of the column. This is the only phase, during which the water crosses through the column from the bottom to the top. 2. Rinse : it is the phase during which the filtering media are rinsed; at the end of this phase the column is ready to start again a new service cycle. NOTE: During regeneration the water supplying is completely inhibited by means of a membrane valve mounted on the outlet line. s.r.l. - ITALY Page 10 of 14 ffd_mi-r0.doc-r0
11 5.3. How to set the time of phases The electronic programmer keep in memory the program by mean of an EEPROM; the time of the day is memorized even in case of power failure (internal not-rechargeable buffer battery, charge life max 5 years without power). The setting or modification of the factory set values, shown on table below, is very easy. Just take note that the start of backwashing phase is controlled by the exciting of channel 1, the starting of the rinse phase by the exciting of channel 2, the end of rinse phase (therefore the end of regeneration) by the elapsed time pre-set for channel 1. For any informations concerning how to operate and modify, see attached special instructions of the programmer. FACTORY SET FOR FILTERS (regeneration once a day) start of backwash end of backwash start of rinse end of rinse at rest position of CH2 channel 1 ON OFF channel 2 ON OFF Starting-up The starting-up of the unit consists of running a first regeneration cycle, during which the filtering media column will be filled of water, all automatic features will be checked and the unit will be prepared to start the service. At the beginning, it is suggested to operate manually, hand-driven the valves, as above explained at the "Regeneration". This way will allow to stop, to run for longer time or to repeat each phase as desired. To start-up the unit, proceed as follows : DISCONNECT ELECTRIC POWER shut-off the outlet valve close the gate valve along the backwash drain line hand-drive the solenoid valve E3 to open the backwashing membrane valves open slowly and gradually the gate valve on backwash drain line. The water will enter inside the vessel from the bottom and, during filling, will expel the air inside it. when only water will come out from the drain, adjust the drain valve in order that the flow rate will be the CLOSEST POSSIBLE to the one listed at paragraph 3.3. When the proper flow rate of backwash has been stated, adjust the gate valve definitely. The backwashing phase must run until all the water coming out the drain is perfectly clear. Hand-drive the solenoid valves E3 to close the backwashing membrane valves. Hand-drive the solenoid valve E1 to open the membrane valve V1 (RINSE); the rinse phase must run until all the water coming out the drain is perfectly clear. Hand-drive the solenoid valves E1 to close the valve V1 and to conclude the regeneration. Switch ON the control panel. Open the outlet valve. Starting now the unit is on service and feeds treated water. s.r.l. - ITALY Page 11 of 14 ffd_mi-r0.doc-r0
12 7. Service & maintenance Automatic iron removal filters are equipments designed to treat raw water supplied from municipalities or from well. ANY OTHER APPLICATIONS OF THE EQUIPMENT DIFFERENT THAN THE MENTIONED ONES IS MADE UNDER THE ONLY RESPONSIBILITY OF THE USER. The correct handling of the equipment requires : take off the water suspended solids of coarse size, if any, by an adequate filtration check that the air and/or water pressure are within the stated values check that the filtered water contains the oxiding agent (usually 0.5 ppm of residual chlorine) Not any further special maintenance operations are required. Not any consumption material is required. The average life of the media filter is approx. 5 8 years, according to the quality of raw water and how often regeneration is featured Disposal In case of disposal of the unit or parts of it, it must be made according to local laws concerning the waste of the materials. Concerning media filter, they are natural products that, at origin state, can be disposed of as natural products. Whether the activated carbon had trapped special and particular substances, the carbon will be classified as same class of the trapped substances. To dispose of them it should be required to identify the class of this waste, by a detailed analysis. s.r.l. - ITALY Page 12 of 14 ffd_mi-r0.doc-r0
13 8. Main components Quantity DESCRIPTION 1 vessel in coated carbon steel (see table DIMENSIONS) 1 internal water distribution system (see following table) # filtering media (see table WEIGHT) 5 membrane valves made in cast-iron (see following table) 3 pilot solenoid valves TYPE V/50Hz 1 electronic programmer type VEMER LOGIK DW2 # galvanized steel fittings several size MODELLO membrane valves distributor V1 V2 V3 V4 V5 number/type FFD 04 1"NC 1¼"NO 1"NC 1¼"NO 1"NC 6 x B175 FFD 06 1"NC 1½"NO 1¼"NC 1½"NO 1¼"NC 6 x B175 FFD 08 1"NC 1½"NO 1¼"NC 1½"NO 1¼"NC 30 plate FFD 10 1"NC 1½"NO 1½"NC 1½"NO 1½"NC 36 plate FFD 13 1"NC 2"NO 1½"NC 2"NO 1½"NC 42 plate FFD 15 1¼"NC 2"NO 2"NC 2"NO 2"NC 56 plate FFD 19 1¼"NC 2½"NO 2½"NC 2½"NO 2½"NC 68 plate FFD 23 1¼"NC 2½"NO 2½"NC 2½"NO 2½"NC 84 plate FFD 30 1½"NC DN80NO 2½"NC DN80NO 2½"NC 104 plate FFD 35 1½"NC DN80NO 2½"NC DN80NO 2½"NC 118 plate FFD 40 1½"NC DN100NO DN80NC DN100NO DN80NC 142 plate s.r.l. - ITALY Page 13 of 14 ffd_mi-r0.doc-r0
14 AUTOMATIC IRON REMOVAL FILTERS INSTRUCTIONS MANUAL 9. Trouble shooting guide PROBLEM CAUSE HOW TO SOLVE The electronic programmer does not electrical power is disconnected connect electrical power switch ON. the programmer is defected replace the programmer The regeneration does not run electrical power is disconnected connect electrical power the programmer is not correctly adjusted adjust correctly the programmer the programmer is defected replace the programmer there is not supplying of pilot fluid (air or water) Regeneration is electrically started but it does not run hydraulically There is a leakage of water to drain during service one or more solenovid valves are defected one or both membrane valves no. 1 and 5 do not close properly. connect properly the supplying of pilot water or compressed air replace the defected solenoid valves check the proper working of the pilot solenoid valves check and clean the seat of the plate of the membrane valve The unit does not feed water the membrane valve no. 2 does not open check the proper working of the pilot solenoid valve replace the nozzle There is a leakage of filtering media to the drain or to the outlet line one nozzle of distribution system is damaged or broken s.r.l. - ITALY Page 14 of 14 ffd_mi-r0.doc-r0
15
16
17
18
19
20
21 s.r.l. via G.Galilei, Segrate (MI) - ITALY AZIENDA CON SISTEMA QUALITÁ CERTIFICATO DA DNV UNI EN ISO 9001/2008 TEL FAX nobel@nobelitaly.it società italiana per lo studio e la realizzazione di apparecchiature ed impianti per il trattamento acqua engineering and manufacturing of equipments and plants for water treatment DICHIARAZIONE DI CONFORMITÀ DECLARATION OF CONFORMITY La Nobel srl dichiara che l apparecchiatura (vedi etichetta in prima pagina) delle serie Nobel srl hereby declares that the equipment (see label on first page) of series FCD../D FACD../D FD../D FFD../D è conforme alle seguenti Direttive Europee: 2006/42/CE 2006/95/CE 2004/108/CE Principali Norme armonizzate osservate durante la progettazione e costruzione: UNI EN ISO 12100:2010 UNI EN (CEI 44-5) - CEI EN Il direttore tecnico è autorizzato alla costituzione del fascicolo tecnico. complies to the requirement of the following European Directives : 2006/42/CE 2006/95/CE 2004/108/CE Besides, the main regulations followed for the design and manufacturing are : UNI EN ISO 12100:2010 UNI EN (CEI 44-5)- CEI EN The technical manager is authorized to manage the technical folder. Direttore Tecnico Technical Manager Giorgio Da Dalt Milano, 18 febbraio 2013 M3.6-r4 sede legale : via dell Unione Milano C.C.I.A.A EXPORT MI Reg. Trib. Milano nº vol.7032 fasc.28 società a responsabilità limitata - cap. soc i.v. - C.F. e P.I. : IT rev. 1
WARNING! Equipment for treatment of water intended for human consumption (Directive 98/83 CE).
WARNING! Equipment for treatment of water intended for human consumption (Directive 98/83 CE). The equipment must be used only for the utilization for which they have been designed, as shown in the technical
More informationML 080 ML 100 INSTRUCTIONS MANUAL
SELF-CLEANING FILTERS SERIE: ML 065 ML 080 ML 100 ML 065/AT ML 080/AT ML 100/AT ML 065/AP ML 080/AP ML 100/AP INSTRUCTIONS MANUAL WARNING! The equipment must be used only for the utilization for which
More informationAUTOMATIC SOFTENERS SERIES: AM/DT AM/RDT AM/DV AM/RDV AM/D METER AM/RD METER INSTRUCTIONS MANUAL WARNING!
AUTOMATIC SOFTENERS SERIES: AM/DT AM/RDT AM/DV AM/RDV AM/D METER AM/RD METER INSTRUCTIONS MANUAL WARNING! The equipment must be used only for the utilization for which they have been designed, as shown
More informationOPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP
This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!
More informationCAST IRON SAFETY VALVE TYPE 6301
CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a
More informationInstallation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.
Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow Model: FP 450-80 Installation Operation Maintenance PAGE 1 OF 5 1. Safety First BERMAD believes that the safety of personnel
More informationBOSS PULISCI PROVA IMPIANTI MEDIA
BOSS PULISCI PROVA IMPIANTI MEDIA Pump for power flushing operations and removal of impurities, suitable for hydraulic, solar, floor systems and for cooling circuits of medium size. Suitable for buildings,
More informationV230 VALVE OPERATING MANUAL
V230 VALVE OPERATING MANUAL S.I.A.T.A. srl Società Italiana apparecchiature trattamento acqua MAN0021 Rev. B Pag 1 di 27 DOCUMENT REVISION REVISION NOTES DATE MAN0029 A BOZZA 19/06/98 MAN0029 B EMISSIONE
More informationV230 VALVE OPERATING MANUAL
V230 VALVE OPERATING MANUAL S.I.A.T.A. srl Società Italiana apparecchiature trattamento acqua MAN0021 Rev. B Pag 1 di 24 DOCUMENT REVISION REVISION NOTES DATE MAN0029 A BOZZA 19/06/98 MAN0029 B EMISSIONE
More informationSafety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14
15 Elster GmbH Edition 7.15 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas
More informationWW-720. Pressure Reducing Control Valve
WW-720 Pressure Reducing Control Valve (Size Ranges: 2-4 and 6-14 ) Installation Operation & Maintenance Page 1 of 6 1. DESCRIPTION The Model 720 Pressure Reducing is an automatic control valve (powered
More informationWW-720. Pressure Reducing Control Valve
WW-720 Pressure Reducing Control Valve (Size Ranges: 2-4 and 6-14 ) Installation Operation & Maintenance Page 1 of 6 1. DESCRIPTION The Model 720 Pressure Reducing is an automatic control valve (powered
More informationPressure Independent Control Series
Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single
More informationGENO -Flushing Compressor Product Data Sheet F 02
GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up
More informationOperation Manual Air Saver Unit ASV5000 Series
9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.
More informationArt PRESSURE REDUCER
FUNCTION ICMA pressure reducers are devices that reduce and stabilize the incoming pressure from the water supply. Pressure reducers allow correct use on domestic systems, reducing malfunctions due to
More informationMounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
More informationFilling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series
Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Main features Designed for automatic filling of sealed heating systems and for protection of the water mains from risk of contamination.
More informationEasy Nest Kits. Installation Suggestions
Easy Nest Kits Installation Suggestions 2 General Recommendations Hydraulics Vacuum breakers should be installed to prevent siphoning. Flexible connectors should follow FRP tank manufacturers recommendations.
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationVERTICAL AIR COMPRESSORS
VERTICAL AIR COMPRESSORS MODEL NO: VE15C150, VE18C150, VE25C150 PART NO: 2226010, 2226020, 2226025 OPERATION & MAINTENANCE INSTRUCTIONS LS0715 INTRODUCTION Thank you for purchasing this CLARKE Vertical
More informationInstallation and Operating Instructions Bypass Flow Meter DST
Installation and Operating Instructions Bypass Flow Meter DST DST_gb_A4_1.0.doc Version 1.0 1 von 10 Contents 1. Foreword... 3 2. Safety... 3 2.1. Symbol and meaning... 3 2.2. General safety directions
More informationIncorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage.
Operating instructions GB VD Burners Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage. To the Equipment Owner: Please read
More information200 PSI COMPRESSORS - MODEL NUMBERS
200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read
More informationVERTICAL AIR COMPRESSORS
VERTICAL AIR COMPRESSORS MODEL NO: VE11C150, VE15C150, VE18C150 PART NO: 2226005, 2226000, 2226015 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE Vertical
More informationAll technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI
PACIFIC MX NITROX BREATHING AIR according to DIN EN 12021 MAX OXYGEN 40% DELIVERY l/min 600 m 3 h 36 PRESSURE BAR 225 PSI 3250 Quality system certified to iso 9001 BREATHING AIR is a product line that
More informationInstallation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr
Installation and Maintenance Manual ECO Filtration Unit with 6-way-Top-Mount-Valve Art. Nr. 300100 300101 300102 Important Details: - Using of this filtration unit for swimming pools and its guard band
More informationProduct Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment
Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces
More information100C Air Compressor Kit
10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is
More informationSerie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E
Serie ECO T Threaded end back flow preventer with controllable reduced pressure zone BRANDONI made in E U R O P E Application fields WATER FIRE FIGHTING DRINKING WATER 74 www.brandoni.it Serie ECO T The
More information6301 TYPE CAST IRON SAFETY VALVES
Pressure (bar) 6301 TYPE CAST IRON SAFETY VALVES FEATURES The 6301 type safety valve is a device designed to protect installations against possible overpressure. It operates automatically and closes when
More informationSERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER
Man500e 09/2006 Installation Operation and Maintenance Instructions SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER INDEX 1. INSTALLATION 2. COMPRESSED AIR SUPPLY 3. FLOW MEASURE
More informationDri-Line Mk3 Monnier Compressed Air Drain Trap
5044050/2 IM-P504-24 CH Issue 2 Dri-Line Mk3 Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and Operation
More informationInstallation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914
Installation, Operating and Maintenance Instructions V914 Cast Iron Flanged Swing Check Valve V914 THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC and CE MARKING The Pressure Equipment Regulations 1999 (SI 1999/2001)
More informationMODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is
More informationGRAVEL/ FILTERS IRRIGATION EQUIPMENT LTD. SERIES APPLICATIONS
IRRIGATION EQUIPMENT LTD. GRAVEL/ S A N D FILTERS SERIES 4000 APPLICATIONS Used as a Primary Filter for water from open reservoirs and recycled water. Most effective for filtration of water heavily contaminated
More informationDifferential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN
Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................
More informationSiphon vessel / Priming aid
Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number
More informationSerie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection
Flanged back flow preventer with controllable reduced pressure zone made in Application fields WATER FIRE FIGHTING DRINKING WATER 64 www.brandoni.it The ECO 3F flanged backflow preventers, which have a
More informationInstallation, commissioning and servicing instructions
48323 www.caleffi.com Pre-adjustable pressure reducing valve with self-contained cartridge Copyright 2015 Caleffi 5350..H AUS series Installation, commissioning and servicing instructions Function Pressure
More information97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO
97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and
More informationTECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY
Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationInstructions for SILEX 1C Mixed bed cartridge filter
D01B-30A-UK1 January 2017 Instructions for SILEX 1C Mixed bed cartridge filter With conductivity sensor Gravity flow or pressure installation SILHORKO-EUROWATER A/S Phone +45 86 57 12 22 DK-8660 Skanderborg
More information2-port seat valves PN25 with externally threaded connections
4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with
More informationMODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE
MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock
More informationInstallation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09
Installation & Maintenance Instructions TEC-11N TIMER Analogue electronic timer 02/09 GENERAL OPERATION The TEC-11N timer is produced using SMT (Surface Mounting Technology), ensuring improved performance
More informationTECHNICAL DATA. Q= Cv S
Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationTECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13
Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationAIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL
00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum
More information420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO
420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this
More informationIMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.
More informationSafety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14
2 Elster GmbH Edition. Translation from the German 22 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas G / G Contents Solenoid valve for gas G / G....
More informationKTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood SECTION 1 - STORAGE 1.1 Preparation and preservation for storage All valves should be properly packed in order to protect the parts
More informationPure Water Power Purification System 4-Stage RODI Operations Manual
Pure Water Power Purification System 4-Stage RODI Operations Manual Flush Valve Lever Quick Disconnect for RO Water Testing Water Supply In Drain Hose Pure Water Out to Waterfed Pole New Machine Setup
More informationWW-730. Pressure Sustaining/Relief Control Valve
WW-730 Pressure Sustaining/Relief Control Valve Installation Operation & Maintenance Page 1 of 6 1. DESCRIPTION The Model 730 Pressure Relief / Sustaining Valve is an automatic control valve designed to
More informationMANUAL. Sesame. Thermoplastic Tank Technologies
MANUAL Sesame Thermoplastic Tank Technologies INSTALLATION AND USER GUIDE CONTENT 1. GENERAL 3 2. IMPORTANT 3 3. INSTALLATION EXPANSION VESSEL 4 4. USE EXPANSION VESSEL 5 5. AIR CELL REPLACEMENT 5 5.1
More informationSolenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Solenoid valves, two-step on/off PMLX REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationManual Actuated Boiler Blowdown Valves
Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety
More informationUSE AND MAINTENANCE MANUAL V360
USE AND MAINTENANCE MANUAL V360 S.I.A.T.A. S.r.l Società Italiana apparecchiature trattamento acqua MAN0031 BOZZA Pag. 1 of Document Revision Revision note Date MAN0031 A Draft S.I.A.T.A. S.r.l Società
More informationINSTALLATION OPERATION MAINTENANCE
Bermad Electrically Controlled On-Off Deluge Valve Model: 400E-3D INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working
More informationManual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany
Manual Degasser DDG-75 April 2007 1 Manual Online Degasser DDG-75 DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE-68766 Hockenheim Germany Tel. +49-6205-9450-0 Fax. +49-6205-9450-33 email info@duratec.com
More informationDual Solenoid Gas Valve Installation
Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions
More informationPilot Operated Pressure Reducing Valve
OPTIONS: USE: Pilot Operated Pressure Reducing Valve Steam & Compressed Air PRV 37 (DN15-DN50) DESCRIPTION The ADCA PRV37 pilot operated pressure reducing valves are designed for use on steam, compressed
More informationUSE AND MAINTENANCE MANUAL V260
USE AND MAINTENANCE MANUAL V260 S.A.T.I.A. srl Società Italiana apparecchiatura trattamento acqua MAN0034 BOZZA Pag. 1 di 21 DOCUMENT REVISION REVISION NOTE DATE MAN0034 DRAFT S.A.T.I.A. srl Società Italiana
More informationOPERATION MANUAL NTF-15
OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE
More information3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II
3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II 306M User Manual English Version Use for company in Europe who will place the product on the market, please
More informationRelated Products: Auto Drain Valve. Model/Specifications. Model
Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl
More informationOPERATION MANUAL NTF-60 Plus
OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)
More informationNeedle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2
Serial No. H-V024-E-7 Needle valve User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation,
More informationOperators & Maintenance Manual OPERATOR S MANUAL USAGE AND MAINTENANCE F100M F100M. Powered Fixed Hoist Ideal for raised swimming pools and hot tubs
MIllside House Anton Road Andover Hampshire SP10 2RW T: +44 (0)1256 896000 E: info@poollifts.co.uk Operators & Maintenance Manual OPERATOR S MANUAL USAGE AND MAINTENANCE F100M F100M Powered Fixed Hoist
More information2-step solenoid valve Type ICLX
Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines for the opening against high differential pressure, e.g. after hot gas
More informationAIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115
AIR COMPRESSOR MODEL NO: CHAMP 3 PART NO: 2225222 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Air Compressor. Please read this manual fully before use
More informationAQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS
AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS TABLE OF CONTENTS TABLE OF CONTENTS...2 GENERAL RECOMMENDATIONS...2 TROUBLESHOOTING GUIDE...3 EXISTING EASY NEST SYSTEM TROUBLESHOOTING GUIDE...4 COMPONENT
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationTECHNICAL DATA OBSOLETE
April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More information42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)
42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor
More informationBermad Pressure Reducing. Model: 42T
Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel
More information2-step solenoid valve Type ICLX
Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines to open against high differential pressure, e.g. after a hot gas defrost
More informationInstallation, commissioning and servicing instructions
488.03 www.reece.com.au Pressure reducing s Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet
More informationMST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap
1250650/6 IM-P125-07 ST Issue 6 MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationInstallation and operating manual. Pneumatic control station LK product no: PCS 1-10
LK product no: PCS 1-10 Article no: 74503 Revision:8 Article no: 74503 Revision: 8 2 (23) Contents 1. General information... 5 2. Safety precautions... 5 2.1 Significance of symbols... 5 2.2 Explanatory
More informationINSTRUCTION MANUAL Pressure Relief Device LPT
INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF
More informationWafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1
Serial No. H-V066-E-3 Wafer Check Valve User s Manual Contents (1) Be sure to read the following description of our product warranty 1 (2) General operating instructions 2 (3) General instructions for
More informationSize : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body
Size : Connection Ends : Min Temperature : Max Temperature : DN 50 to 200 Flanged ISO PN 10/16 ( ISO PN16 for DN200 ) 0 C + 50 C Max Pressure : 16 Bars Specifications : Tangential type Dry dial Magnetic
More informationVACCUPERM Vacuum chlorine gas dosing systems
VACCUPERM Vacuum chlorine gas dosing systems Vaccuperm, precise and safe dosing. www.clorep.es VACCUPERM INTRODUCTION Vaccuperm provides a proven and reliable technology of vacuum gas dosing. Handling,
More informationINDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS
IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, INTRODUCTION Hydropneumatic tanks are designed to be used in potable water supply installations as a part of the pressure booster set in order to ensure the adequate
More informationCARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition
CARTRIDGE FILTERS TECHNICAL MANUAL MT 080 Installation, commissioning and maintenance instructions 08/02 Edition 1 2 CONTENTS 1.0 PAGE INTRODUCTION 1.1 MAIN FEATURES 1.2 OPERATION 1.3 CLOSING OF HEAD WITH
More informationOWNER S TECHNICAL MANUAL
EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,
More informationSlam Shut Valves SCN
Slam Shut Valves SCN SCN > Slam shut valves Introduction SCN is a compact safety device (SAV) which quickly intercept gas flow whenever the pressure under monitoring reaches a pre-set limits, or whenever
More informationSUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm
SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation Size: inch / mm Every Ross Valve shall be hydrostatically tested for body integrity and tight seating
More informationHalsey Taylor Owners Manual STOP!
Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY
More informationPRESSURE REGULATOR LBM SERIES
VIRTUAL CATALOGUE FAIL TO OPEN REGULATOR HIGH FLOW COEFFICIENT WIDE PRESSURE-REGULATION RANGE FAST RESPONSE PRESSURE REGULATOR LBM SERIES FULL SEAL AT ZERO FLOW CAN BE SUPPLIED WITH MINIMUM / MAXIMUM PRESSURE
More information200 PSI FAST-FILL AIR SOURCE KIT
200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of
More informationEaton Filtration, LLC
Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual
More informationVibration isolation system 1VIS10W. User manual
Vibration isolation system 1VIS10W User manual Standa 2014 Table of contents 1. General information 3 1.1. Introduction 3 1.1.1. Safety 5 1.2. Location of the table 5 1.3. Air supply requirements 5 2.
More informationOXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:
OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle
More informationOPERATING INSTRUCTIONS
0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0
More information