5 issue 10 FULL EQUIPMENT DESCRIPTION Application f zone 1: The controller compartment PGC5000A (which controls from one to four Isothermal Ovens type PGC5000B PGC5000C) houses a power supply and PCBs f the single board computer, oven controller and the front panel that employs an intrinsically safe circuit f the front panel mounted external keypad. This compartment relies upon type py protection f Zone 1 area; therefe within the compartment is the safety device f moniting the differential pressure and alarming provision. Meover, non-sparking concept na is additionally applied to demonstrate the non-sparking design necessary f the pressurization py protection mode. In case of overpressure and purge control device option (x-purge option) the protection of the compartment relies on px protection The type PGC5000B and PGC5000C gas chromatograph are designed to operate automatically analyzing process streams and repting the analysis of the analyzer. The type PGC5000B and PGC5000C gas chromatograph communicate the analytical detection and analytical process scheduling back and fth to the type PGC5000A Master Controller by means of fiber optic CAN bus. The PGC5000B and PGC5000C module consists of the following three sections: - The electronics compartment (located on the left side) - The oven compartment (located on the right side) houses various heaters and detects. Despite these components have their own protection mode, the non-sparking concept na is additionally applied with the pressurization py protection mode - The top compartment is exposed to hazardous atmosphere and houses the Electronic Pressure Control and a manifold f incoming air as required f the air-operated solenoids and regulated purge air f the electronics and oven compartments. Application f zone 2: As EN and EN standards were applied behind the py protection to demonstrate the non-sparking design of the analyzer, PGC5000A, PGC5000B, PGC5000C and PGC5007 can also be marked Ex na without pressurization. The pz protection mode can be marked on the PGC5000A, PGC5000B and PGC5000C whatever the purge control device option (z-purge option) f the electronic enclosure. PURCHASED Ex COMPONENTS OF THE APPARATUS The optional exlink Ethernet communication link (Ex Component) f the PGC5000A Master Controller: Designation of product Manufacturer Type Document of reference Plg-in connect Cooper Crouse-Hinds GmbH exlink IECEx BKI X MARKING ABB Inc Lewisburg - USA Serial number : B Year of manufacturer: B WARNING PRESSURIZED ENCLOSURE WARNING DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT F PGC5000A Type : PGC5000A Ex ib py IIB + H2 T4 Gb Total internal free volume : 62 L Minimum air supply flow rate : 17,84 L/min. Maximum leakage flow rate : 21,66 L/min Maximum overpressure : 3,3 mbar Ex na IIB + H2 T4 Gc Page 1 of 7

6 issue 10 F PGC5000B PGC5000C Oven Electronics Type : PGC5000B PGC 5000C Ex d e py IIB + H2 T4BT2 Gb Total internal free volume : 37,94 L Minimum air supply flow rate : 39,36 L/min. Maximum leakage flow rate : 79,00 L/min Maximum overpressure : 1,76 mbar Ex d e na IIB + H2 T4BT2 Gc F PGC5000B PGC5000C Isothermal oven Type : PGC5000B PGC 5000C Ex d e py IIB + H2 T4BT2 Gb Total internal free volume : 36,81 L Minimum air supply flow rate : 106,47 L/min. Maximum leakage flow rate : 169,05 L/min Maximum overpressure : 2,33 mbar Ex d e na IIB + H2 T4BT2 Gc F PGC5000A with X-PURGE option Type : PGC5000A Ex ib px IIB + H2 T4 Gb Total internal free volume : 62,01 L Minimum air supply flow rate : 17,84 L/min. Maximum leakage flow rate : 21,66 L/min Maximum overpressure : 3,3 mbar Ex pz IIB + H2 T4 Gc Page 2 of 7

7 issue 10 F PGC5000B PGC5000C Oven Electronics with X-PURGE option Type : PGC5000B PGC 5000C Ex d e ib px IIB + H2 T4BT2 Gb Total internal free volume : 37,94 L Minimum air supply flow rate : 39,36 L/min. Maximum leakage flow rate : 79,00 L/min Maximum overpressure : 1,76 mbar Ex d e pz IIB + H2 T4BT2 Gc F PGC5000B PGC5000C Isothermal oven with X-PURGE option Type : PGC5000B PGC 5000C Ex d e ib px IIB + H2 T4BT2 Gb Total internal free volume : 36,81 L Minimum air supply flow rate : 106,47 L/min. Maximum leakage flow rate : 169,05 L/min Maximum overpressure : 2,33 mbar Ex d e pz IIB+H2, T4, T3 T2 F PGC5000B PGC5000C Oven Electronics with option type 883 Airless oven Type : PGC5000B PGC 5000C Ex d e py IIB + H2 T4BT2 Gb Total internal free volume : 37,94 L Minimum air supply flow rate : 39,36 L/min. Maximum leakage flow rate : 79,00 L/min Maximum overpressure : 1,76 mbar Ex d e na IIB + H2 T4BT2 Gc Page 3 of 7

8 issue 10 F PGC5000B PGC5000C Isothermal oven with option type 883 Airless oven Type : PGC5000B PGC 5000C Ex d e py IIB + H2 T4BT2 Gb Total internal free volume : 36,81 L Minimum air supply flow rate : 106,47 L/min. Maximum leakage flow rate : 169,05 L/min Maximum overpressure : 2,33 mbar Ex d e na IIB + H2 T4BT2 Gc F PGC5000B PGC5000C Oven Electronics with option type 867 Flame Photometric detect FPD Type : PGC5000B PGC 5000C Ex d e mc py IIB + H2 T4BT2 Gb Total internal free volume : 37,94 L Minimum air supply flow rate : 39,36 L/min. Maximum leakage flow rate : 79,00 L/min Maximum overpressure : 1,76 mbar Ex d e mc na IIB + H2 T4BT2 Gc F PGC5000B PGC5000C Isothermal oven with with option type 867 Flame Photometric detect FPD Type : PGC5000B PGC 5000C Ex d e mc py IIB + H2 T4BT2 Gb Total internal free volume : 36,81 L Minimum air supply flow rate : 106,47 L/min. Maximum leakage flow rate : 169,05 L/min Maximum overpressure : 2,33 mbar Ex d e mc na IIB + H2 T4BT2 Gc Page 4 of 7

9 issue 10 F PGC5000B PGC5000C Oven Electronics with type 888 temperature program module option Type : PGC5000B PGC 5000C Ex d e ib px IIB + H2 T2 T3 Gb Total internal free volume : 37,94 L Minimum air supply flow rate : 39,36 L/min. Maximum leakage flow rate : 79,00 L/min Maximum overpressure : 1,76 mbar F PGC5000B PGC5000C Isothermal oven with type 888 temperature program module option Type : PGC5000B PGC 5000C Ex d e ib px IIB + H2 T2 T3 Gb Total internal free volume : 36,81 L Minimum air supply flow rate : 106,47 L/min. Maximum leakage flow rate : 169,05 L/min Maximum overpressure : 2,33 mbar F PGC5009 Column enclosure Type : PGC5009 Ex d e ib px IIB + H2 T2 T3 Gb Minimum air supply flow rate : L/min. Maximum leakage flow rate : L/min Maximum overpressure : 6.5 mbar Purge wait time : 18,20 Min F PGC5009 Electronics enclosure Type : PGC5009 Ex d e ib px IIB+H2 T2 T3 Gb Minimum air supply flow rate : L/min. Minimum overpressure : 0.5 mbar Maximum leakage flow rate : L/min Maximum overpressure : 3.83 mbar RANGE DETAILS PGC5000A : Master Controller f the PGC PGC5000B : PGC f standard, simpler liquid and vap stream applications PGC5000C : PGC f complex, liquid and vap stream applications Smart Oven with Integrated Controller: PGC5000B C without PGC5000A Page 5 of 7

10 issue 10 RATINGS Electrical ratings are specified as follow: PGC5000A : 120 VA maximum PGC5000B : 1200 VA maximum PGC5000C : 1600 VA maximum FULL CONDITIONS OF CERTIFICATION (ou FULL SCHEDULE OF LIMITATIONS) - Ambient temperature : 0 to 50 C - When PGC5000 is configured as a PGC5007 High Heat T3, a warning label f Type 791 heater block should be added : WARNING AFTER DE-ENERGIZING, DELAY 30 MINUTES BEFORE OPENING. - When the optional exlink Ethernet communication link is used f the PGC5000A Master Controller, limitations f use shall include: Permissible ambient temperature f PGC5000: 0 C up to +40 C In the non-plugged condition, the connect and appliance connect must not be alive. - The SBC2 assembly shall only be used in an area of not me than pollution degree 2, as defined in IEC The SBC2 assembly shall be installed in an enclosure that provides a degree of protection not less than IP54 in accdance with EN Transient protection shall be provided that is set at a level not exceeding 140 % of the peak rated voltage value at the supply terminals to the equipment. - When the optional Flame Photometric Detect (FPD) is used: To be installed and used only as a component in the PGC5000. No consideration of faults due to protection level mc and clearances accding to Table 1, IEC , Clause To be Installed within enclosure with IP54 rating better, pollution degree 2 better; No creepages clearances considered due to wking voltages below 85 Vdc; Supplied by internal power supply with transient protection at a level not exceeding 140% of peak rated voltage. Maximum surface temperature f FPD Electrometer is 62.2 C when operated within PGC5000 at 50 C ambient. ROUTINE TESTS * F pressurized compartments including PGC5000A controller, PGC5000B Oven Electronics, PGC5000B Isothermal oven, PGC5000C Oven Electronics, PGC5000C Isothermal oven and heating device : - IEC / 17.1: The perfmance of safety devices shall be verified. - IEC / 17.2: The measured flow rate shall be not greater than the maximum leakage flow rate specified by the manufacturer. - IEC / : Dielectric strength shall be verified by a test at the test voltage 1500 V r.m.s. and maintained f at least 1 min. * F heating device and 800: - IEC / 5: Checking of the safety device and the temperature class. - IEC / 7.2: Dielectric strength shall be verified by a test at the test voltage 1500 V r.m.s. and maintained f at least 1 min. * F FID detect 799 : - IEC / 16: Routine test under the pressure of 20 bar during at least 10 s without exceeding 1 minute (welded construction). * Each printed circuit board part number: 852A A A A A016 must be submitted to dielectric strength accding to IEC / Page 6 of 7

11 issue 10 APPARATUS OVERVIEW Figure 1: PGC5000A Master Controller Figure 2: PGC5000B Gas chromatograph Figure 3: PGC5000C Gas chromatograph ADDITIONAL MANUFACTURING LOCATIONS None. Page 7 of 7

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:

More information

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Supplementary Operator s Manual 42/24-14 EN Rev. 3 Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary

More information

A Unified Marking System for Ex Equipment

A Unified Marking System for Ex Equipment CERTEX Appointed Ex Laboratory Reg No: 1999/027771/07 (Pty) Ltd Government Approved Inspection Authority T0104 PO Box 467 Tel: +27 (11) 316 4601 Olifantsfontein Fax: +27 (11) 316 5670 1665 E- mail: info@explolabs.co.za

More information

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Z, Y, and X PURGE INDICATORS / CONTROLLERS PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories

More information

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual

More information

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS 1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS EXPLOSION PROTECTION In addition to the type approval and certification of industrial weighing systems concerned with accuracy, equipment that is also

More information

Certificate of Compliance

Certificate of Compliance FF0 002 Certificate of Compliance Certificate: 1714037 (LR) Issued to: Emerson Process Management GmbH & Co. OHG Industriestrasse 1 Hasselroth, 63594 GERMANY Attention: Gabriele Blendin The products listed

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Maxum. PD PA AP Maxum II Official Product Specifications. Specifications Overview 1. Maxum II Common Specifications 2. Airbath or Airless Oven 3

Maxum. PD PA AP Maxum II Official Product Specifications. Specifications Overview 1. Maxum II Common Specifications 2. Airbath or Airless Oven 3 Specifications Overview 1 Maxum II Common Specifications 2 Maxum PD PA AP Maxum II Official Product Specifications Brochure Airbath or Airless Oven 3 Modular Oven 4 Ovens 5 Detectors and Associated Devices

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element

More information

Further technical information is available on

Further technical information is available on 1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

Maxum. PD PA AP Maxum II Official Product Specifications. Specifications Overview 1. Maxum II Common Specifications 2. Airless or Airbath Oven 3

Maxum. PD PA AP Maxum II Official Product Specifications. Specifications Overview 1. Maxum II Common Specifications 2. Airless or Airbath Oven 3 Specifications Overview 1 Maxum II Common Specifications 2 Maxum PD PA AP Maxum II Official Product Specifications Brochure Airless or Airbath Oven 3 Modular Oven 4 Ovens 5 Detectors 6 Valve Specifications

More information

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere! The portable Gas Chromatograph is now more versatile than ever. DPS Instruments is pleased to present the newest Portable Companion 2 Gas Chromatograph with room for 2 Detectors. The Companion 2 GC was

More information

Field Certification Certificate of Compliance

Field Certification Certificate of Compliance 1 Field Certification Certificate of Compliance Certificate: 2460594 Master Contract: 244849 Project: 2460594 Date Issued: 2011-12-23 Issued to: Sirio Sistemi Elettronici SpA Via Fleming 16 59100 Prato

More information

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm 0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection

More information

i4zo Simplified (Zone 2) Pressu rized Enciosure system a a. h a i MI in M.C.A. According to EN (pz) Test No. TOV 03 ATEX 2095 X Description

i4zo Simplified (Zone 2) Pressu rized Enciosure system a a. h a i MI in M.C.A. According to EN (pz) Test No. TOV 03 ATEX 2095 X Description M.C.A. BOLLATE (MI) MISURA - CONTROLLO - AUTOMAZIONE TEL.. 02.35.12.774 FAX 02.33.26.00.70 F840 Simplified (Zone 2) Pressu rized Enciosure system According to EN 60079 -- 2 (pz) Test No. TOV 03 ATEX 2095

More information

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev. 3G Operating instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 01. July 2011/Rev. 0 Operating Instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 1 July 2011 / Rev.

More information

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof Hazardous Location Equipment - Canada Equipment listed in this category for Hazardous Locations is also suitable for installations in areas that are non-hazardous locations and, unless referenced in the

More information

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote Installation, Operation, & Maintenance Manual Mustang Sample Conditioning System MODEL: Watlow Controller P53 Direct, P53 Remote Conforms to UL STDS 61010-1 & 1203 Certified to CSA STD C22.2 Nos. 61010-1

More information

PROCESS AUTOMATION INSTALLATION AND OPERATION MANUAL MANUAL

PROCESS AUTOMATION INSTALLATION AND OPERATION MANUAL MANUAL PROCESS AUTOMATION INSTALLATION AND OPERATION MANUAL MANUAL 6500 Purge and Pressurization System 6000 Series Purge/Pressurization System I/O Manual With regard to the supply of products, the current issue

More information

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS SECTION 7 ELECTRICITY CHAPTERS A APPROACH B DOCUMENTS, REGULATIONS AND

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review) Certificate Number: MASC MS/11-127X Issue: 09 October 2017 Expire: 09 October 2020 Page: 1 of 5 IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

PURGEX X Purge Controller E Version. User s Manual

PURGEX X Purge Controller E Version. User s Manual PURGEX X Purge Controller E Version User s Manual This page intentionally left blank Information in this document is subject to change without notice. All terms mentioned in this manual that are known

More information

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. General specifications. Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 70024080 Date Issued: 2017-07-04 Issued to: ecom instruments GmbH Industriestrasse 2 Assamstadt, Baden Wurttemburg 97959 GERMANY Attention: Kevin Spence The

More information

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions VS18/26 with PROFINET and EtherNet/IP Interface ATEX Installation Instructions INDEX 1. INTENDED USAGE 3 2. OPERATING MANUAL ATEX 4 2.1 General conditions 4 2.2 Installation 5 2.3 Operating 5 2.4 Failures

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Hoffman Purge/Pressurization Manual for Models PLCF1YZ PLCB1YZ

Hoffman Purge/Pressurization Manual for Models PLCF1YZ PLCB1YZ Hoffman Purge/Pressurization Manual for Models PLCF1YZ PLCB1YZ This manual covers Type Y/Z - Purge with Leakage Compensation CONTENTS: 1. Specification Sheet LC Y/Z Purge/Pressurization Units 2. Application

More information

Hoffman Purge/Pressurization Manual for Models for PCFF1YZ PCFB1YZ

Hoffman Purge/Pressurization Manual for Models for PCFF1YZ PCFB1YZ Hoffman Purge/Pressurization Manual for Models for PCFF1YZ PCFB1YZ This manual covers Y/Z - Purge with Continuous Flow CONTENTS: 1. Specification Sheet CF Y/Z Purge/Pressurization Unit 2. Application Suitability

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type

More information

BGA158 Series CE Approved Class A Shutoff Gas Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting

More information

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

UHrasonic Sensor VEGASON60 type series SN6*.CI**H*** Certificate No.: IECEx PTa 06.0099X Issue No.: 0 Status: Current Date of Issue: 2006-12-27 Page 1 of 3 Applicant: VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Electrical Apparatus: Optional

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

BGA158 Series CE Approved Class B Shutoff Gas Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve Installation Instructions BGA158 Issue Date March 22, 2016 BGA158 Series CE Approved Class B Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated shutoff valve

More information

VG5 Supplementary instructions

VG5 Supplementary instructions VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...

More information

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions

More information

Autocalibration Systems For In Situ Oxygen Analyzers

Autocalibration Systems For In Situ Oxygen Analyzers Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more! After years of development and testing, DPS Instruments is pleased to present the newest, most expandable and versatile Gas Chromatography Systems in history. The DPS 600 Series GC systems are the world

More information

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres Page 1 of 7 Title Plan electrical installations for explosive atmospheres Level 5 Credits 8 Purpose This unit standard is intended for use in the training and assessment of people who work with electrical

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Valvex Valves for Mining Applications

Valvex Valves for Mining Applications Valvex Valves for Mining pplications roven technology The Electronic Drive Systems product group at Voith Turbo GmbH & Co. KG develops and produces explosion-proof Valvex solenoid valves and valve assemblies.

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Guidelines to the standard IEC60601

Guidelines to the standard IEC60601 EUROPEAN POWER SUPPLY MANUFACTURERS ASSOCIATION (Visit the EPSMA website at www.epsma.org) Medical Approvals for Power Supplies Guidelines to the standard IEC60601 Revision Date: 2009-09-12 This document

More information

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017 Procedure Instruction of program Explosion Pressure - Test Round 2017 Content 1 General Performance... 2 2 Measurand / Characteristic of interest... 2 3 Test Item and Configurations... 2 3.1 Components...

More information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases P r o d u c t i n f o r m at i o n EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total

More information

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI Bernhard Thomas September 2018 EnCal 3000 prochain Energy in Gas with ROI Agenda 1 Introduction The new EnCal 3000 prochain Technical details Outlook Introduction 2 What we measure and why 3 What we measure

More information

RTD temperature probes

RTD temperature probes RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating

More information

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features GE Measurement & Control RTX 1000H Series Versatile Transmitters for a World of Pressure GE Measurement & Control is renowned for the design and manufacture of compact and rugged high performance pressure

More information

PURGEX X Purge Controller D Version

PURGEX X Purge Controller D Version PURGEX X Purge Controller D Version User s Manual This page intentionally left blank Information in this document is subject to change without notice. All terms mentioned in this manual that are known

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM-20/25 GM-40/45 Issue Date 1298 UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function

More information

Karandikar Laboratories Pvt. Ltd., Gat No. 142, Boisar Chilhar Road, At Betegaon, Boisar (E), Taluka Palghar, Maharashtra

Karandikar Laboratories Pvt. Ltd., Gat No. 142, Boisar Chilhar Road, At Betegaon, Boisar (E), Taluka Palghar, Maharashtra Last Amended on - Page 1 of 41 1 SAFETY 1. Safety Testing IEC 61010:2010 Single Fault Conditions IEC 61010-1 Cls. 4.4 And Similar Visual checks Verification of electrical parameters given on label IEC

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB Audio, video and similar electronic apparatus Safety requirements

CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB Audio, video and similar electronic apparatus Safety requirements Page 1 of 7 CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB 8898 2011 Audio, video and similar electronic apparatus Safety requirements This analysis is intended to identify and analyze

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking: direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting

More information

PROCESS AUTOMATION INSTALLATION AND OPERATION MANUAL 6000 SERIES PURGE/PRESSURIZATION SYSTEM

PROCESS AUTOMATION INSTALLATION AND OPERATION MANUAL 6000 SERIES PURGE/PRESSURIZATION SYSTEM PROCESS AUTOMATION INSTALLATION AND OPERATION MANUAL 6000 SERIES PURGE/PRESSURIZATION SYSTEM With regard to the supply of products, the current issue of the following document is applicable: The General

More information

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet Data sheet MEGAS 2.0 Gas analysis with direct C-Level Calculation and Bus-Connection Mesa Industrie-Elektronik GmbH Neckarstraße 19, D-45768 Marl info@mesa-gmbh.de +49 (0) 2365-97 45 1-0 +49 (0) 2365-97

More information

EnCal 3000 Gas Chromatograph Hardware Manual g

EnCal 3000 Gas Chromatograph Hardware Manual g EnCal 3000 Gas Chromatograph Hardware Manual 73022344 g 01.06.2015 EnCal 3000 Hardware Manual 01/06/2015 Contact Information... 3 Safety Information... 4 Gas quality measurement system EnCal 3000... 5

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

GAS FUEL VALVE FORM AGV5 OM 8-03

GAS FUEL VALVE FORM AGV5 OM 8-03 ALTRONIC AGV5 OPERATING MANUAL GAS FUEL VALVE FORM AGV5 OM 8-03 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY TO OPERATORS

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST

More information

Pressure switch KP-E. Data sheet

Pressure switch KP-E. Data sheet Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

PurgEx. Z Purge Indicator. User s Manual

PurgEx. Z Purge Indicator. User s Manual PurgEx Z Purge Indicator User s Manual This page intentionally left blank Information in this document is subject to change without notice. All terms mentioned in this manual that are known to be trademarks

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Installation, Operations, and Maintenance Manual D , Rev B December Rosemount CT5800 Continuous Gas Analyzer

Installation, Operations, and Maintenance Manual D , Rev B December Rosemount CT5800 Continuous Gas Analyzer Installation, Operations, and Maintenance Manual D-7010-0059, Rev B December 2017 Rosemount CT5800 Continuous Gas Analyzer Preface Published by Emerson. All possible care has been taken in the preparation

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER

More information

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S02 Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S06* Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Pneumatic pressure switch 20DD

Pneumatic pressure switch 20DD Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better

More information

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 Issue: 9 22 nd March 2013 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate

More information

Certificate of Conformity

Certificate of Conformity Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocols:

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

PurgEx. X Purge Controller N Version. User s Manual

PurgEx. X Purge Controller N Version. User s Manual PurgEx X Purge Controller N Version User s Manual This page intentionally left blank Information in this document is subject to change without notice. All terms mentioned in this manual that are known

More information

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres Page 1 of 8 Title Conduct detailed inspection of electrical installations for explosive atmospheres Level 5 Credits 5 Purpose This unit standard is intended for use in the training and assessment of people

More information

IECEx certification of Non-Electrical Ex Equipment

IECEx certification of Non-Electrical Ex Equipment IECEx certification of Non-Electrical Ex Equipment Thierry Houeix Ex Certification Officer Brief history of Non Electrical Ex Equipment standards In 2008, during the SC31M Plenary meeting it was decided

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

VR46.5V(A)/VR86.5V(A) SERIES

VR46.5V(A)/VR86.5V(A) SERIES VR46.5V(A)/VR86.5V(A) SERIES COMACT COMBINATION GAS CONTROS WITH INTEGRATED 1:1 GAS/AIR REGUATOR FOR AUTOMATIC IGNITION SYSTEMS SECIFICATIONS INSTRUCTION SHEET Subject to change without notice. rinted

More information