5 issue 10 FULL EQUIPMENT DESCRIPTION Application f zone 1: The controller compartment PGC5000A (which controls from one to four Isothermal Ovens type PGC5000B PGC5000C) houses a power supply and PCBs f the single board computer, oven controller and the front panel that employs an intrinsically safe circuit f the front panel mounted external keypad. This compartment relies upon type py protection f Zone 1 area; therefe within the compartment is the safety device f moniting the differential pressure and alarming provision. Meover, non-sparking concept na is additionally applied to demonstrate the non-sparking design necessary f the pressurization py protection mode. In case of overpressure and purge control device option (x-purge option) the protection of the compartment relies on px protection The type PGC5000B and PGC5000C gas chromatograph are designed to operate automatically analyzing process streams and repting the analysis of the analyzer. The type PGC5000B and PGC5000C gas chromatograph communicate the analytical detection and analytical process scheduling back and fth to the type PGC5000A Master Controller by means of fiber optic CAN bus. The PGC5000B and PGC5000C module consists of the following three sections: - The electronics compartment (located on the left side) - The oven compartment (located on the right side) houses various heaters and detects. Despite these components have their own protection mode, the non-sparking concept na is additionally applied with the pressurization py protection mode - The top compartment is exposed to hazardous atmosphere and houses the Electronic Pressure Control and a manifold f incoming air as required f the air-operated solenoids and regulated purge air f the electronics and oven compartments. Application f zone 2: As EN and EN standards were applied behind the py protection to demonstrate the non-sparking design of the analyzer, PGC5000A, PGC5000B, PGC5000C and PGC5007 can also be marked Ex na without pressurization. The pz protection mode can be marked on the PGC5000A, PGC5000B and PGC5000C whatever the purge control device option (z-purge option) f the electronic enclosure. PURCHASED Ex COMPONENTS OF THE APPARATUS The optional exlink Ethernet communication link (Ex Component) f the PGC5000A Master Controller: Designation of product Manufacturer Type Document of reference Plg-in connect Cooper Crouse-Hinds GmbH exlink IECEx BKI X MARKING ABB Inc Lewisburg - USA Serial number : B Year of manufacturer: B WARNING PRESSURIZED ENCLOSURE WARNING DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT F PGC5000A Type : PGC5000A Ex ib py IIB + H2 T4 Gb Total internal free volume : 62 L Minimum air supply flow rate : 17,84 L/min. Maximum leakage flow rate : 21,66 L/min Maximum overpressure : 3,3 mbar Ex na IIB + H2 T4 Gc Page 1 of 7
6 issue 10 F PGC5000B PGC5000C Oven Electronics Type : PGC5000B PGC 5000C Ex d e py IIB + H2 T4BT2 Gb Total internal free volume : 37,94 L Minimum air supply flow rate : 39,36 L/min. Maximum leakage flow rate : 79,00 L/min Maximum overpressure : 1,76 mbar Ex d e na IIB + H2 T4BT2 Gc F PGC5000B PGC5000C Isothermal oven Type : PGC5000B PGC 5000C Ex d e py IIB + H2 T4BT2 Gb Total internal free volume : 36,81 L Minimum air supply flow rate : 106,47 L/min. Maximum leakage flow rate : 169,05 L/min Maximum overpressure : 2,33 mbar Ex d e na IIB + H2 T4BT2 Gc F PGC5000A with X-PURGE option Type : PGC5000A Ex ib px IIB + H2 T4 Gb Total internal free volume : 62,01 L Minimum air supply flow rate : 17,84 L/min. Maximum leakage flow rate : 21,66 L/min Maximum overpressure : 3,3 mbar Ex pz IIB + H2 T4 Gc Page 2 of 7
7 issue 10 F PGC5000B PGC5000C Oven Electronics with X-PURGE option Type : PGC5000B PGC 5000C Ex d e ib px IIB + H2 T4BT2 Gb Total internal free volume : 37,94 L Minimum air supply flow rate : 39,36 L/min. Maximum leakage flow rate : 79,00 L/min Maximum overpressure : 1,76 mbar Ex d e pz IIB + H2 T4BT2 Gc F PGC5000B PGC5000C Isothermal oven with X-PURGE option Type : PGC5000B PGC 5000C Ex d e ib px IIB + H2 T4BT2 Gb Total internal free volume : 36,81 L Minimum air supply flow rate : 106,47 L/min. Maximum leakage flow rate : 169,05 L/min Maximum overpressure : 2,33 mbar Ex d e pz IIB+H2, T4, T3 T2 F PGC5000B PGC5000C Oven Electronics with option type 883 Airless oven Type : PGC5000B PGC 5000C Ex d e py IIB + H2 T4BT2 Gb Total internal free volume : 37,94 L Minimum air supply flow rate : 39,36 L/min. Maximum leakage flow rate : 79,00 L/min Maximum overpressure : 1,76 mbar Ex d e na IIB + H2 T4BT2 Gc Page 3 of 7
8 issue 10 F PGC5000B PGC5000C Isothermal oven with option type 883 Airless oven Type : PGC5000B PGC 5000C Ex d e py IIB + H2 T4BT2 Gb Total internal free volume : 36,81 L Minimum air supply flow rate : 106,47 L/min. Maximum leakage flow rate : 169,05 L/min Maximum overpressure : 2,33 mbar Ex d e na IIB + H2 T4BT2 Gc F PGC5000B PGC5000C Oven Electronics with option type 867 Flame Photometric detect FPD Type : PGC5000B PGC 5000C Ex d e mc py IIB + H2 T4BT2 Gb Total internal free volume : 37,94 L Minimum air supply flow rate : 39,36 L/min. Maximum leakage flow rate : 79,00 L/min Maximum overpressure : 1,76 mbar Ex d e mc na IIB + H2 T4BT2 Gc F PGC5000B PGC5000C Isothermal oven with with option type 867 Flame Photometric detect FPD Type : PGC5000B PGC 5000C Ex d e mc py IIB + H2 T4BT2 Gb Total internal free volume : 36,81 L Minimum air supply flow rate : 106,47 L/min. Maximum leakage flow rate : 169,05 L/min Maximum overpressure : 2,33 mbar Ex d e mc na IIB + H2 T4BT2 Gc Page 4 of 7
9 issue 10 F PGC5000B PGC5000C Oven Electronics with type 888 temperature program module option Type : PGC5000B PGC 5000C Ex d e ib px IIB + H2 T2 T3 Gb Total internal free volume : 37,94 L Minimum air supply flow rate : 39,36 L/min. Maximum leakage flow rate : 79,00 L/min Maximum overpressure : 1,76 mbar F PGC5000B PGC5000C Isothermal oven with type 888 temperature program module option Type : PGC5000B PGC 5000C Ex d e ib px IIB + H2 T2 T3 Gb Total internal free volume : 36,81 L Minimum air supply flow rate : 106,47 L/min. Maximum leakage flow rate : 169,05 L/min Maximum overpressure : 2,33 mbar F PGC5009 Column enclosure Type : PGC5009 Ex d e ib px IIB + H2 T2 T3 Gb Minimum air supply flow rate : L/min. Maximum leakage flow rate : L/min Maximum overpressure : 6.5 mbar Purge wait time : 18,20 Min F PGC5009 Electronics enclosure Type : PGC5009 Ex d e ib px IIB+H2 T2 T3 Gb Minimum air supply flow rate : L/min. Minimum overpressure : 0.5 mbar Maximum leakage flow rate : L/min Maximum overpressure : 3.83 mbar RANGE DETAILS PGC5000A : Master Controller f the PGC PGC5000B : PGC f standard, simpler liquid and vap stream applications PGC5000C : PGC f complex, liquid and vap stream applications Smart Oven with Integrated Controller: PGC5000B C without PGC5000A Page 5 of 7
10 issue 10 RATINGS Electrical ratings are specified as follow: PGC5000A : 120 VA maximum PGC5000B : 1200 VA maximum PGC5000C : 1600 VA maximum FULL CONDITIONS OF CERTIFICATION (ou FULL SCHEDULE OF LIMITATIONS) - Ambient temperature : 0 to 50 C - When PGC5000 is configured as a PGC5007 High Heat T3, a warning label f Type 791 heater block should be added : WARNING AFTER DE-ENERGIZING, DELAY 30 MINUTES BEFORE OPENING. - When the optional exlink Ethernet communication link is used f the PGC5000A Master Controller, limitations f use shall include: Permissible ambient temperature f PGC5000: 0 C up to +40 C In the non-plugged condition, the connect and appliance connect must not be alive. - The SBC2 assembly shall only be used in an area of not me than pollution degree 2, as defined in IEC The SBC2 assembly shall be installed in an enclosure that provides a degree of protection not less than IP54 in accdance with EN Transient protection shall be provided that is set at a level not exceeding 140 % of the peak rated voltage value at the supply terminals to the equipment. - When the optional Flame Photometric Detect (FPD) is used: To be installed and used only as a component in the PGC5000. No consideration of faults due to protection level mc and clearances accding to Table 1, IEC , Clause To be Installed within enclosure with IP54 rating better, pollution degree 2 better; No creepages clearances considered due to wking voltages below 85 Vdc; Supplied by internal power supply with transient protection at a level not exceeding 140% of peak rated voltage. Maximum surface temperature f FPD Electrometer is 62.2 C when operated within PGC5000 at 50 C ambient. ROUTINE TESTS * F pressurized compartments including PGC5000A controller, PGC5000B Oven Electronics, PGC5000B Isothermal oven, PGC5000C Oven Electronics, PGC5000C Isothermal oven and heating device : - IEC / 17.1: The perfmance of safety devices shall be verified. - IEC / 17.2: The measured flow rate shall be not greater than the maximum leakage flow rate specified by the manufacturer. - IEC / : Dielectric strength shall be verified by a test at the test voltage 1500 V r.m.s. and maintained f at least 1 min. * F heating device and 800: - IEC / 5: Checking of the safety device and the temperature class. - IEC / 7.2: Dielectric strength shall be verified by a test at the test voltage 1500 V r.m.s. and maintained f at least 1 min. * F FID detect 799 : - IEC / 16: Routine test under the pressure of 20 bar during at least 10 s without exceeding 1 minute (welded construction). * Each printed circuit board part number: 852A A A A A016 must be submitted to dielectric strength accding to IEC / Page 6 of 7
11 issue 10 APPARATUS OVERVIEW Figure 1: PGC5000A Master Controller Figure 2: PGC5000B Gas chromatograph Figure 3: PGC5000C Gas chromatograph ADDITIONAL MANUFACTURING LOCATIONS None. Page 7 of 7
IECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:
More informationSupplementary Operator s Manual 42/24-14 EN Rev. 3
Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary
More informationA Unified Marking System for Ex Equipment
CERTEX Appointed Ex Laboratory Reg No: 1999/027771/07 (Pty) Ltd Government Approved Inspection Authority T0104 PO Box 467 Tel: +27 (11) 316 4601 Olifantsfontein Fax: +27 (11) 316 5670 1665 E- mail: info@explolabs.co.za
More informationZ, Y, and X PURGE INDICATORS / CONTROLLERS
PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories
More informationUser s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E
User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual
More information1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS
1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS EXPLOSION PROTECTION In addition to the type approval and certification of industrial weighing systems concerned with accuracy, equipment that is also
More informationCertificate of Compliance
FF0 002 Certificate of Compliance Certificate: 1714037 (LR) Issued to: Emerson Process Management GmbH & Co. OHG Industriestrasse 1 Hasselroth, 63594 GERMANY Attention: Gabriele Blendin The products listed
More informationIntrinsically safe solenoid valves on/off controls - ATEX certification
www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6
More informationMaxum. PD PA AP Maxum II Official Product Specifications. Specifications Overview 1. Maxum II Common Specifications 2. Airbath or Airless Oven 3
Specifications Overview 1 Maxum II Common Specifications 2 Maxum PD PA AP Maxum II Official Product Specifications Brochure Airbath or Airless Oven 3 Modular Oven 4 Ovens 5 Detectors and Associated Devices
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm
Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element
More informationFurther technical information is available on
1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationMaxum. PD PA AP Maxum II Official Product Specifications. Specifications Overview 1. Maxum II Common Specifications 2. Airless or Airbath Oven 3
Specifications Overview 1 Maxum II Common Specifications 2 Maxum PD PA AP Maxum II Official Product Specifications Brochure Airless or Airbath Oven 3 Modular Oven 4 Ovens 5 Detectors 6 Valve Specifications
More informationGeneral Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!
The portable Gas Chromatograph is now more versatile than ever. DPS Instruments is pleased to present the newest Portable Companion 2 Gas Chromatograph with room for 2 Detectors. The Companion 2 GC was
More informationField Certification Certificate of Compliance
1 Field Certification Certificate of Compliance Certificate: 2460594 Master Contract: 244849 Project: 2460594 Date Issued: 2011-12-23 Issued to: Sirio Sistemi Elettronici SpA Via Fleming 16 59100 Prato
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 1.5 mm
0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush
More informationManual Power relay SR853
Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection
More informationi4zo Simplified (Zone 2) Pressu rized Enciosure system a a. h a i MI in M.C.A. According to EN (pz) Test No. TOV 03 ATEX 2095 X Description
M.C.A. BOLLATE (MI) MISURA - CONTROLLO - AUTOMAZIONE TEL.. 02.35.12.774 FAX 02.33.26.00.70 F840 Simplified (Zone 2) Pressu rized Enciosure system According to EN 60079 -- 2 (pz) Test No. TOV 03 ATEX 2095
More informationModulating Valves for Atmospheric, Infrared, and Direct Fired Burners
BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More information3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.
3G Operating instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 01. July 2011/Rev. 0 Operating Instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 1 July 2011 / Rev.
More informationHazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof
Hazardous Location Equipment - Canada Equipment listed in this category for Hazardous Locations is also suitable for installations in areas that are non-hazardous locations and, unless referenced in the
More informationInstallation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote
Installation, Operation, & Maintenance Manual Mustang Sample Conditioning System MODEL: Watlow Controller P53 Direct, P53 Remote Conforms to UL STDS 61010-1 & 1203 Certified to CSA STD C22.2 Nos. 61010-1
More informationPROCESS AUTOMATION INSTALLATION AND OPERATION MANUAL MANUAL
PROCESS AUTOMATION INSTALLATION AND OPERATION MANUAL MANUAL 6500 Purge and Pressurization System 6000 Series Purge/Pressurization System I/O Manual With regard to the supply of products, the current issue
More informationPART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS
PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS SECTION 7 ELECTRICITY CHAPTERS A APPROACH B DOCUMENTS, REGULATIONS AND
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationIA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)
Certificate Number: MASC MS/11-127X Issue: 09 October 2017 Expire: 09 October 2020 Page: 1 of 5 IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)
More informationGM Series Dual-Block Multi-Function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series
More informationPURGEX X Purge Controller E Version. User s Manual
PURGEX X Purge Controller E Version User s Manual This page intentionally left blank Information in this document is subject to change without notice. All terms mentioned in this manual that are known
More informationTechnical Data. General specifications. Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationCertificate of Compliance
FF0002 Certificate of Compliance Certificate: 70024080 Date Issued: 2017-07-04 Issued to: ecom instruments GmbH Industriestrasse 2 Assamstadt, Baden Wurttemburg 97959 GERMANY Attention: Kevin Spence The
More informationVS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions
VS18/26 with PROFINET and EtherNet/IP Interface ATEX Installation Instructions INDEX 1. INTENDED USAGE 3 2. OPERATING MANUAL ATEX 4 2.1 General conditions 4 2.2 Installation 5 2.3 Operating 5 2.4 Failures
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationHoffman Purge/Pressurization Manual for Models PLCF1YZ PLCB1YZ
Hoffman Purge/Pressurization Manual for Models PLCF1YZ PLCB1YZ This manual covers Type Y/Z - Purge with Leakage Compensation CONTENTS: 1. Specification Sheet LC Y/Z Purge/Pressurization Units 2. Application
More informationHoffman Purge/Pressurization Manual for Models for PCFF1YZ PCFB1YZ
Hoffman Purge/Pressurization Manual for Models for PCFF1YZ PCFB1YZ This manual covers Y/Z - Purge with Continuous Flow CONTENTS: 1. Specification Sheet CF Y/Z Purge/Pressurization Unit 2. Application Suitability
More informationOSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide
OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature
More informationTechnical Data. Dimensions
0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type
More informationBGA158 Series CE Approved Class A Shutoff Gas Valve
Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that
More informationTechnical Data. Dimensions
0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm
Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting
More informationUHrasonic Sensor VEGASON60 type series SN6*.CI**H***
Certificate No.: IECEx PTa 06.0099X Issue No.: 0 Status: Current Date of Issue: 2006-12-27 Page 1 of 3 Applicant: VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Electrical Apparatus: Optional
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationBGA158 Series CE Approved Class B Shutoff Gas Valve
Installation Instructions BGA158 Issue Date March 22, 2016 BGA158 Series CE Approved Class B Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated shutoff valve
More informationVG5 Supplementary instructions
VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...
More informationSafety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions
More informationAutocalibration Systems For In Situ Oxygen Analyzers
Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from
More informationTechnical Data. Dimensions
00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationEnvironmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!
After years of development and testing, DPS Instruments is pleased to present the newest, most expandable and versatile Gas Chromatography Systems in history. The DPS 600 Series GC systems are the world
More informationNZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres
Page 1 of 7 Title Plan electrical installations for explosive atmospheres Level 5 Credits 8 Purpose This unit standard is intended for use in the training and assessment of people who work with electrical
More informationIECEx Certificate of Conformity Annexe
for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationValvex Valves for Mining Applications
Valvex Valves for Mining pplications roven technology The Electronic Drive Systems product group at Voith Turbo GmbH & Co. KG develops and produces explosion-proof Valvex solenoid valves and valve assemblies.
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationGuidelines to the standard IEC60601
EUROPEAN POWER SUPPLY MANUFACTURERS ASSOCIATION (Visit the EPSMA website at www.epsma.org) Medical Approvals for Power Supplies Guidelines to the standard IEC60601 Revision Date: 2009-09-12 This document
More informationPTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017
Procedure Instruction of program Explosion Pressure - Test Round 2017 Content 1 General Performance... 2 2 Measurand / Characteristic of interest... 2 3 Test Item and Configurations... 2 3.1 Components...
More informationEuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
P r o d u c t i n f o r m at i o n EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total
More informationBernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI
Bernhard Thomas September 2018 EnCal 3000 prochain Energy in Gas with ROI Agenda 1 Introduction The new EnCal 3000 prochain Technical details Outlook Introduction 2 What we measure and why 3 What we measure
More informationRTD temperature probes
RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating
More informationRTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features
GE Measurement & Control RTX 1000H Series Versatile Transmitters for a World of Pressure GE Measurement & Control is renowned for the design and manufacture of compact and rugged high performance pressure
More informationPURGEX X Purge Controller D Version
PURGEX X Purge Controller D Version User s Manual This page intentionally left blank Information in this document is subject to change without notice. All terms mentioned in this manual that are known
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
More informationUL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM-20/25 GM-40/45 Issue Date 1298 UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function
More informationKarandikar Laboratories Pvt. Ltd., Gat No. 142, Boisar Chilhar Road, At Betegaon, Boisar (E), Taluka Palghar, Maharashtra
Last Amended on - Page 1 of 41 1 SAFETY 1. Safety Testing IEC 61010:2010 Single Fault Conditions IEC 61010-1 Cls. 4.4 And Similar Visual checks Verification of electrical parameters given on label IEC
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationCERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB Audio, video and similar electronic apparatus Safety requirements
Page 1 of 7 CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB 8898 2011 Audio, video and similar electronic apparatus Safety requirements This analysis is intended to identify and analyze
More informationDual Solenoid Gas Valve Installation
Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationINVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:
direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting
More informationPROCESS AUTOMATION INSTALLATION AND OPERATION MANUAL 6000 SERIES PURGE/PRESSURIZATION SYSTEM
PROCESS AUTOMATION INSTALLATION AND OPERATION MANUAL 6000 SERIES PURGE/PRESSURIZATION SYSTEM With regard to the supply of products, the current issue of the following document is applicable: The General
More informationMEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet
Data sheet MEGAS 2.0 Gas analysis with direct C-Level Calculation and Bus-Connection Mesa Industrie-Elektronik GmbH Neckarstraße 19, D-45768 Marl info@mesa-gmbh.de +49 (0) 2365-97 45 1-0 +49 (0) 2365-97
More informationEnCal 3000 Gas Chromatograph Hardware Manual g
EnCal 3000 Gas Chromatograph Hardware Manual 73022344 g 01.06.2015 EnCal 3000 Hardware Manual 01/06/2015 Contact Information... 3 Safety Information... 4 Gas quality measurement system EnCal 3000... 5
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationGAS FUEL VALVE FORM AGV5 OM 8-03
ALTRONIC AGV5 OPERATING MANUAL GAS FUEL VALVE FORM AGV5 OM 8-03 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY TO OPERATORS
More informationReg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST
More informationPressure switch KP-E. Data sheet
Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationPurgEx. Z Purge Indicator. User s Manual
PurgEx Z Purge Indicator User s Manual This page intentionally left blank Information in this document is subject to change without notice. All terms mentioned in this manual that are known to be trademarks
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationInstallation, Operations, and Maintenance Manual D , Rev B December Rosemount CT5800 Continuous Gas Analyzer
Installation, Operations, and Maintenance Manual D-7010-0059, Rev B December 2017 Rosemount CT5800 Continuous Gas Analyzer Preface Published by Emerson. All possible care has been taken in the preparation
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER
More informationValve Proving System VDK 200 A S02
Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationValve Proving System VDK 200 A S06*
Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationPneumatic pressure switch 20DD
Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better
More informationBA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9
BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 Issue: 9 22 nd March 2013 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate
More informationCertificate of Conformity
Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocols:
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationPurgEx. X Purge Controller N Version. User s Manual
PurgEx X Purge Controller N Version User s Manual This page intentionally left blank Information in this document is subject to change without notice. All terms mentioned in this manual that are known
More informationNZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres
Page 1 of 8 Title Conduct detailed inspection of electrical installations for explosive atmospheres Level 5 Credits 5 Purpose This unit standard is intended for use in the training and assessment of people
More informationIECEx certification of Non-Electrical Ex Equipment
IECEx certification of Non-Electrical Ex Equipment Thierry Houeix Ex Certification Officer Brief history of Non Electrical Ex Equipment standards In 2008, during the SC31M Plenary meeting it was decided
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationVR46.5V(A)/VR86.5V(A) SERIES
VR46.5V(A)/VR86.5V(A) SERIES COMACT COMBINATION GAS CONTROS WITH INTEGRATED 1:1 GAS/AIR REGUATOR FOR AUTOMATIC IGNITION SYSTEMS SECIFICATIONS INSTRUCTION SHEET Subject to change without notice. rinted