Testing results for Hose Patch, hydraulic hose repair system

Size: px
Start display at page:

Download "Testing results for Hose Patch, hydraulic hose repair system"

Transcription

1 Testing results for Hose Patch, hydraulic hose repair system Test Date: 17/3/2017 Test By, Daniel Adams (Branch Manager CEJN Australia) Report compiled By Daniel Adams Page 1

2 Test Particulars The hose patch hose repair kit consists of two main parts, an outer sealing clamp which fits over the outside of the hose and an inner hose joining/support joiner. Both parts come in various sizes to allow fitting to various hose sizes and types. Having this combination of parts allows the system to be used in two ways: 1. With the sealing clamp straight onto the hose 2. With the sealing clamp onto the outside of the hose with the inner joiner fitted for extra internal support. The purpose of this testing is to measure the performance of the system in the two usable formats. Equipment used: Test Rig: Maximator Hydraulic test unit using water as test media. NATA gauge certification numbers: APTS (gauge) APTS (transducer and chart recorder) Method: 1. Hose test pieces were damaged mechanically in order to replicate typical in field damage. 2. Only the patch section of the kit is applied to the pre damaged test piece as per the instructions 3. The test piece is tested, observed and recorded. 4. The test piece is then cut and the system is set up using the joiner 5. The test piece is tested, observed and recorded. Results: Each page contains information about the normal working pressure and burst pressure of the hose as well as the pressures the test piece was exposed to during the test. There is one hose type/size to a page. There are two chart recording for each hose type, one for the Patch test and one for the Patch with Barb test. Chart recordings are labelled as to what hose type it was and which type of test it is. Page 2

3 Hose Type 1 R12 Working Pressure 280 bar Internal diameter 1 Burst Pressure 1120 bar Patch only test 37 bar 68 bar Patch and Barb 293 bar 450 bar Comments: Patch test held 37bar but leaked with at a quickening drip from between the clamps when more pressure was applied until no more pressure could built up at 68bar. Patch and Barb test- held pressure at 293 bar (above WP for the hose) for 2 minutes before the pressure was increased to 420 bar (1.5 x WP = Test Pressure) with no loss of pressure after settling. Page 3

4 Hose Type ¾ R15 Working Pressure 413 bar Internal diameter ¾ Burst Pressure 1655 bar Patch only test 116 bar 139 bar Patch and Barb 445 bar 723 bar Comments: Patch test held 75 bar but leaked with a drip from between the clamps pressure was applied until no more pressure could built up at 116bar. Patch and Barb test- held pressure at 445 bar (above WP for the hose) for aprox. 1 min before the pressure was increased to 715 bar momentarily with no loss of pressure before being taken to a maximum of 723 bar where leakage occurred. Page 4

5 Hose Type ¾ R12 Working Pressure 280 bar Internal diameter ¾ Burst Pressure 1120 bar Patch only test 116 bar 139 bar Patch and Barb 284 bar 474 bar Comments: Patch test held 116 bar but leaked with a drip from between the clamps pressure was applied until no more pressure could built up at 116bar. Patch and Barb test- held pressure at 284 bar (above WP for the hose) for 1 minutes before the pressure was increased to 420 bar momentarily with no loss of pressure before being taken to a maximum of 474 bar. Page 5

6 Hose Type ½ R12 Working Pressure 280 bar Internal diameter ½ Burst Pressure 1120 bar Patch only test 73 bar 96 bar Patch and Barb 277 bar 743 bar Comments: Patch test held 68 bar but leaked with a drip from between the clamps pressure was applied until no more pressure could built up at 96bar. Patch and Barb test- held pressure at 277 bar for aprox. 1 min before the pressure was increased to 458 bar for another minute with no loss of pressure before being taken to a maximum of 743 bar where leakage occurred. Page 6

7 Hose Type ½ 4SP Working Pressure 413 bar Internal diameter ½ Burst Pressure 1655 bar Patch only test 163bar 182 bar Patch and Barb 450 bar 743 bar Comments: Patch test held 162 bar but leaked with a drip from between the clamps pressure was applied until no more pressure could built up at 182bar. Patch and Barb test- held pressure at 417 bar (above WP for the hose) for aprox. 1 min before the pressure was increased to 720 bar momentarily with no loss of pressure before being taken to a maximum of 743 bar where leakage occurred. Page 7

8 Hose Type ½ 2SN Working Pressure 275 bar Internal diameter 2SN Burst Pressure 1100 bar Patch only test 101 bar 151 bar Patch and Barb 277 bar 768 bar Comments: Patch test held pressure of approx 100 bar but leaked with a drip from between the clamps, pressure was applied until no more pressure could built up at 151 bar. Patch and Barb test- held pressure at 277 bar (above WP for the hose) for aprox. 1 min before the pressure was increased to 415 bar for about 1 minute with no loss of pressure before being taken to a maximum of 768 bar where leakage occurred Page 8

9 Hose Type 5/82SN Working Pressure 250 bar Internal diameter 5/8 Burst Pressure 1000 bar Patch only test 97 bar 135 bar Patch and Barb 243 bar 943 bar Comments: Patch test held pressure of aprox 97 bar but leaked with a drip from between the clamps, pressure was applied until no more pressure could built up at 135 bar. Patch and Barb test- held pressure at 243 bar for aprox. 1 min before the pressure was increased to 360 bar for about 1.5 minutes with no loss of pressure before being taken to a maximum of 943 bar where leakage occurred Page 9

10 Hose Type 3/82SN Working Pressure 330 bar Internal diameter 3/8 Burst Pressure 1320 bar Patch only test 136 bar 198 bar Patch and Barb 399 bar 828 bar Comments: Patch test held pressure of approx 97 bar but leaked with dripping from between the clamps, pressure was applied until no more pressure could built up at 135 bar. Patch and Barb test- held pressure at 399 bar (well above WP for the hose) for aprox. 1 min before the pressure was taken to a maximum of 943 bar where leakage occurred Page 10

11 Hose Type ¼ 2SN Working Pressure 400 bar Internal diameter ¼ Burst Pressure 1600 bar Patch only test 31 bar 64 bar Patch and Barb 426 bar 1070 bar Comments: Patch test held pressure of aprox 31bar but leaked with dripping from between the clamps, pressure was applied until no more pressure could built up at 64 bar. Patch and Barb testheld pressure at 426 bar (well above WP for the hose) for aprox. 1 min before the pressure was taken to a maximum of 1070 bar where leakage occurred Page 11

12 Hose Type 3/8 R7 Working Pressure 155 bar Internal diameter 3/8 Burst Pressure 620 bar Patch only test N/A N/A Patch and Barb 201 bar 313 bar Comments: Patch test- No test data could be obtained due to the high leakage rates. Patch and Barb test- held pressure at 201 bar (well above WP for the hose) for aprox. 1 min before the pressure was taken to a maximum of 313 bar where leakage occurred Page 12

13 Hose Type 1/4 R7 Working Pressure 190 bar Internal diameter 1/4 Burst Pressure 760 bar Patch only test N/A N/A Patch and Barb 194 bar 333 bar Comments: Patch test- No test data could be obtained due to the high leakage rates. Patch and Barb test- held pressure at 194 bar (well above WP for the hose) for aprox. 1 min before the pressure was taken to a maximum of 333 bar where leakage occurred Page 13

14 Summary Generally the Hose Patch system works well but with some limitation when used in the patch only mode. Patch and Joiner Mode- In all cases hoses joined with the full system (patch and joiner) were able to be pressurised a minimum of 1.5 times the working pressure** of the tested hose with no failures or distortions around the patched area. **(note 1.5x Working pressure is the test pressure calculation applied under ISO1402 for new hose assemblies) Patch Mode- In all tests in the patch mode there was some leakage. All leakage observed was dripping as rates relative to pressure applied rather than a jet stream. Also in this mode it was observed that some blistering of the hose cover outside of the patch was present due to the test fluid seeping back between the hose layers. On average a working pressure of around 100 bar could be achieved with minimal leakage in most cases. This mode would be an emergency only type patch. Thermoplastic assemblies could not be tested in this mode due to excessive leakage. All tests were assembled using a torque wrench and torqued in a cross pattern sequence, this seems to be key in applying they pressure evenly to the clamp to ensure the best possible result. Page 14

Torque Specifications

Torque Specifications SENR3130-10 Torque Specifications All Caterpillar Products S/N From the library of Barrington Diesel Club CONTENT General Information 01/07/2005 Introduction to Torque 01/07/2005 Torque-Turn 01/07/2005

More information

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves Tools Required: Flow Meter Pressure gauge Holding valve test block Wrenches for installation of

More information

Hydraulic Reliability & Preventive Maintenance Report

Hydraulic Reliability & Preventive Maintenance Report Hydraulic Reliability & Preventive Maintenance Report The following is a report of the test, procedures and recommendations for the in-plant press. This information was recorded on May 10 th and 11 th,

More information

Hose Manufacturing Data

Hose Manufacturing Data Hydraulic & Offshore Supplies Hose Manufacturing Data YOUR GATEWAY TO GLOBAL SUPPLY HOSE ASSEMBLIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE HOSE MANUFACTURING DATA STORAGE Detailed

More information

Safety Guidelines FOR ULTRA HIGH-PRESSURE HYDRAULIC APPLICATIONS.

Safety Guidelines FOR ULTRA HIGH-PRESSURE HYDRAULIC APPLICATIONS. Safety Guidelines FOR ULTRA HIGH-PRESSURE HYDRAULIC APPLICATIONS www.cejn.com 2 GUIDELINES......for Working with Ultra High-Pressure Hydraulic Tools Working with ultra high-pressure hydraulics is a serious

More information

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. than the water inlet pressure to the concentrate Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler

More information

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

INSTALLATION, OPERATION AND MAINTENANCE GUIDE INSTALLATION, OPERATION AND Placement in Pipeline System When installing Process Development & Control s ElastoTITE Elastomer-Hinged Check Valves in a pipeline, a minimum of five pipe diameters should

More information

REACH COMPLIANT 2500 WEIGEL STREET CADILLAC, MI

REACH COMPLIANT 2500 WEIGEL STREET CADILLAC, MI REACH 2500 WEIGEL STREET CADILLAC, MI 49601 Phone: 800-250-5132 Local: (231) 779-4390 Fax: (231) 779-4399 E-Mail: sales@piranhahose.com Web Site: www.piranhahose.com sales@piranhahose.com www.piranhahose.com

More information

DBML-60/80 Squeeze Tool

DBML-60/80 Squeeze Tool DBML-60/80 Squeeze Tool OPERATORS MANUAL Description The Mustang Model DBML-60/80 Hydraulic squeeze tool has been manufactured since 1995. A Mustang 3 3/4 bore doubleacting cylinder producing 41,000 lbs

More information

Schroeder Check Test Point System

Schroeder Check Test Point System Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000

More information

Warning: NEVER ALTER TEST EQUIPMENT

Warning: NEVER ALTER TEST EQUIPMENT PAGE 1 OF 6 General: Pressure Testing Shop Built Tanks Pressure testing tanks with either positive pressure or vacuum can be a very dangerous exercise. It is important to understand the equipment involved

More information

Captain Wellhead & Tree

Captain Wellhead & Tree North Sea Platform 13-3/8 Casing Hanger Annulus Pack-off Product & Procedure Overview Ref: AB374RM 04-07-2007 The following is based on limited information available at the time of this evaluation History:

More information

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE February 9, 1998 Foam 101a A BLADDER TANK WITH 1. DESCRIPTION A Wet Pipe Bladder Tank Foam/Water System is a standard wet pipe automatic sprinkler system capable of discharging a foam/water solution automatically

More information

CO2 Tank Conversion Kit P.N , P.N , and P.N

CO2 Tank Conversion Kit P.N , P.N , and P.N Foodservice Group Multiplex Beverage Equipment Installation Instructions for CO2 Tank Conversion Kit P.N. 002247, P.N. 0022505, and P.N. 0025099 Introduction The following instructions cover the installation

More information

Universal Charging and Testing Unit FPU-1

Universal Charging and Testing Unit FPU-1 1. DESCRIPTION 1.1. FUNCTION The charging and testing unit FPU-1 is used to charge accumulators with nitrogen or to check or to change the existing pre-charge pressure in accumulators. For this purpose

More information

Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions

Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions WIL-IO-SD-001-10 1 Description The Triple Duty Valve (TDV) / Triple Service Valve (TSV) is a quiet operating heavy-duty

More information

Parks Operations. Neighbourhood Outdoor Rink Program. Procedures

Parks Operations. Neighbourhood Outdoor Rink Program. Procedures Parks Operations Neighbourhood Outdoor Rink Program Procedures Table of Contents Neighbourhood Outdoor Rink Program... 1 Neighbourhood Volunteer Form... 2 Rink Installation Instructions... 3 Rink Board

More information

Instructions for Installation, Operating and Maintenance

Instructions for Installation, Operating and Maintenance Instructions for Installation, Operating and Maintenance for ABO butterfly valves series 500 1) Introduction 2) Safety Instructions 3) Valve Identification 4) Transportation and Storage 5) Installation

More information

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1. Spilt body Flange ball valve TC-205MFF-PN1640 Series PED Category I,II TC-205MFF-PN1640 User Manual English Version Use for company in Europe who will place the product on the market, please amend which

More information

Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices

Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices Status as of 2014-01 Principles of testing Insulating hose assemblies on cable cutting devices

More information

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump

More information

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve Technical Information Series PRM General Description Series PRM reducing valves are used to regulate pressure, in one area of a circuit, below normal system pressure. This style valve is well suited to

More information

COSASCO 3600 PSI SINGLE SERVICE VALVE MAINTENANCE

COSASCO 3600 PSI SINGLE SERVICE VALVE MAINTENANCE COSASCO 3600 PSI SINGLE SERVICE VALVE MAINTENANCE 11841 Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 Revision History Record www.cosasco.com Page: 2 of

More information

IP16 HYDRAULIC INTENSIFIER. Safety, Operation and Maintenance Stanley Black & Decker, Inc. New Britain, CT U.S.A /2011 Ver.

IP16 HYDRAULIC INTENSIFIER. Safety, Operation and Maintenance Stanley Black & Decker, Inc. New Britain, CT U.S.A /2011 Ver. IP16 HYDRAULIC INTENSIFIER Safety, Operation and Maintenance USER MANUAL 2011 Stanley Black & Decker, Inc. New Britain, CT 06053 U.S.A. 10413 3/2011 Ver. 2 TABLE OF CONTENTS SAFETY SYMBOLS...4 SAFETY

More information

IP16 HYDRAULIC INTENSIFIER

IP16 HYDRAULIC INTENSIFIER IP16 HYDRAULIC INTENSIFIER USER MANUAL Safety, Operation and Maintenance 2014 Stanley Black & Decker, Inc. New Britain, CT 06053 U.S.A. 10413 7/2017 Ver. 4 TABLE OF CONTENTS SAFETY SYMBOLS...4 SAFETY

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

Instruction Manual. Maximum Operating Pressure 1,500 bar

Instruction Manual. Maximum Operating Pressure 1,500 bar Hydraulic Bolt Tensioners Model DBT Series Maximum Operating Pressure 1,500 bar ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au Phone: +61 7 3865

More information

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID. CONTENTS Introduction Pressure Pressure Drop Temperature Rating Bend Radius Conclusion Additional Information SIDEBAR: Understanding Hydraulic Hose Reinforcement INTRODUCTION Hydraulic hose has a finite

More information

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6 Equipment Affected Technical Bulletin LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6 Ford 4.2L V-6 powered tractors with LPG fuel systems. Part Description Discrepancy Fuel Pressure Lock-off

More information

SPL31A SPL31A-N SPL31A-S HYDRAULIC SPIKE PULLER

SPL31A SPL31A-N SPL31A-S HYDRAULIC SPIKE PULLER SPL31A SPL31A-N SPL31A-S HYDRAULIC SPIKE PULLER USER MANUAL Safety, Operation and Maintenance 2013 Stanley Black & Decker, Inc. New Britain, CT 06053 U.S.A. 72926 10/2017 Ver. 11 2 SPL31 User Manual NOTES

More information

HPB25 Hydraulic Paving Breaker

HPB25 Hydraulic Paving Breaker INSTRUCTION MANUAL HPB25 Hydraulic Paving Breaker Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product at www.greenlee.com

More information

Inflatable Packers for Grouting 11/10/00

Inflatable Packers for Grouting 11/10/00 Introduction Inflatable Packers for Grouting 11/10/00 Inflatable packers are frequently used for grout injection in geotechnical applications for structural reinforcement and/or water-proofing of foundations,

More information

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS O-Ring Face Seal Hose TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS O-Ring Face Seal METAL FORMING SOLUTIONS THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS Table of

More information

ENGINEERING TECHNICAL REPORT

ENGINEERING TECHNICAL REPORT SSP DUOLOK FITTINGS ON 1.000 x 0.139 WALL 316SS TUBING ENGINEERING TECHNICAL REPORT SSP 8250 Boyle Parkway Twinsburg, Ohio 44087 U.S.A. mysspusa.com 1.330.425.4250 1 TABLE OF CONTENTS 1.0 Introduction

More information

NITROGEN PRESSURE REGULATOR LEAK TESTING KIT

NITROGEN PRESSURE REGULATOR LEAK TESTING KIT 7 OPERATING INSTRUCTIONS NITROGEN PRESSURE REGULATOR LEAK TESTING KIT 1 15 15 2 c o o l 25 m 2 3 1 2 3 4 5 5 35 25 4 3 4 5 3 1 1 2 6 8 5 53-3 1 9 6 53-7 7 99 Washington Street Melrose, MA 2176 Phone 781-665-14

More information

Hoses and Lances 20,000 PSI

Hoses and Lances 20,000 PSI Jetstream provides a full arrangement of hoses and flex lances for ultra high pressure waterblasting. The hoses and lances are designed to be durable and reliable for any 20,000 psi application. A large

More information

TROUBLESHOOTING Hydraulics

TROUBLESHOOTING Hydraulics 2. Protect hose. Nylon and urethane sleeving and spring guards can be used to protect the cover from abrasion. See page 62 for more information. 3. Change to a hose with a cover that is compatible with

More information

F-08 HIGH-PRESSURE HOSE USED IN CO2 SYSTEM

F-08 HIGH-PRESSURE HOSE USED IN CO2 SYSTEM Guideline No.: F-08(201510) F-08 HIGH-PRESSURE HOSE USED IN CO2 SYSTEM Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements,

More information

Hose Management Inspection Guidelines for HP Drilling and Production Hoses

Hose Management Inspection Guidelines for HP Drilling and Production Hoses Jubilee Industrial Estate, Ashignton, Northumberland NE63 8UB, UK Hose Management Inspection Guidelines for HP Drilling and Production Hoses Rev No Date Amended Amended By Approved By 04 26/02/09 T. Henderson

More information

Test Report. Test Report Smart Systems Limited Incorporating Smart Extrusions. Page 1 of 78

Test Report. Test Report Smart Systems Limited Incorporating Smart Extrusions. Page 1 of 78 Test Report 8365614. Smart Systems Limited Incorporating Smart Extrusions Page 1 of 78 Introduction. This report has been prepared by Adam Pearce and relates to the activity detailed below: Job/Registration

More information

Model GPR Primary Pressure Regulating Valve. Instruction Manual

Model GPR Primary Pressure Regulating Valve. Instruction Manual Model GPR-2000 Primary Pressure Regulating Valve Instruction Manual Please read this instruction manual thoroughly before using the primary pressure regulating valve, so that you may do so correctly and

More information

Manufacturers Crimp Guidelines Sure Seal Crevice Free Hose Couplings

Manufacturers Crimp Guidelines Sure Seal Crevice Free Hose Couplings Manufacturers Crimp Guidelines Sure Seal Crevice Free Hose Couplings Caution Sure Seal Crevice Free Hose Couplings are to be used on rubber food hose approved by Key Industrial, Napa, CA. They are intended

More information

Aeroquip Fluid Conveyance

Aeroquip Fluid Conveyance Aeroquip Fluid Conveyance Technical Focus Rynglok Hydraulic Tube Fitting System Eaton s Aeroquip Brand RYNGLOK tube fitting system is the system of choice for aerospace hydraulic tubing for military, commercial

More information

MANUAL BE SERIES Test Benches

MANUAL BE SERIES Test Benches The CustomCrimp Manual BE Series Test Benches are designed with features that make proof and burst testing of hydraulic hose assemblies a quick and easy procedure. CUSTOMIZED AND SPECIAL DESIGN BENCHES

More information

double rotary environmental cartridge mechanical seals 302 TM series

double rotary environmental cartridge mechanical seals 302 TM series double rotary environmental cartridge mechanical seals 302 TM series first4seals plc, mount street, bradford, west yorkshire. bd3 9sn united kingdom Tel: +44 (0) 1274 720775 Fax: +44 (0) 1274 729022 email:

More information

Standard: NFPA 86 Process Ovens and Furnaces. NFPA 85 Boiler and Combustion Systems Hazards Code

Standard: NFPA 86 Process Ovens and Furnaces. NFPA 85 Boiler and Combustion Systems Hazards Code 11699 Brookpark Road Cleveland, OH 44130 USA P: 216-749-2992 F: 216-398-8403 www.combustionsafety.com Why Test? Main and pilot safety shutoff valves keep fuel out of the firebox when equipment is shut

More information

DR19 HYDRAULIC DIGGER

DR19 HYDRAULIC DIGGER DR19 HYDRAULIC DIGGER USER MANUAL Safety, Operation and Maintenance 2014 Stanley Black & Decker, Inc. New Britain, CT 06053 U.S.A. 62213 9/2014 Ver. 4 TABLE OF CONTENTS SAFETY SYMBOLS...4 SAFETY PRECAUTIONS...5

More information

SD67 HYDRAULIC SPIKE DRIVER. Safety, Operation and Maintenance Stanley Black & Decker, Inc. New Britain, CT U.S.A /2013 Ver.

SD67 HYDRAULIC SPIKE DRIVER. Safety, Operation and Maintenance Stanley Black & Decker, Inc. New Britain, CT U.S.A /2013 Ver. SD67 HYDRAULIC SPIKE DRIVER Safety, Operation and Maintenance USER MANUAL 2011 Stanley Black & Decker, Inc. New Britain, CT 06053 U.S.A. 17488 4/2013 Ver. 4 TABLE OF CONTENTS SAFETY SYMBOLS...4 SAFETY

More information

Product Bulletin No.: D99-RRV2015-PIB-001

Product Bulletin No.: D99-RRV2015-PIB-001 Product Bulletin No.: D99-RRV2015-PIB-001 Titan BX Automatic Pressure Relief Valves Issue Date: April 22, 2016 Subject: Product: Affected Assemblies Objectives: Structural failure of a Titan Type BX pneumatically-operated

More information

ENERGY BLADE 3K4. Energy Blade Installation Instructions

ENERGY BLADE 3K4. Energy Blade Installation Instructions ENERGY BLADE 3K4 Energy Blade Installation Instructions 1 Contents General information 2 Scope of these instructions 2 Product information 2 Designated use 3 Warranty 3 Safety instructions 4 Assembly and

More information

PLEASE NOTE: Pressures for 200mm (8ins) and 250mm (10ins) are based on the use of METALFLEX Braided Braid

PLEASE NOTE: Pressures for 200mm (8ins) and 250mm (10ins) are based on the use of METALFLEX Braided Braid METCONAB B-FLEX Stainless Steel Annular Convoluted Hose. A close pitch hose with a high degree of flexibility suitable for most applications and normally supplied. BRAID Single or double layers of Stainless

More information

Automatic Non-freeze Valve NF6

Automatic Non-freeze Valve NF6 172-65134MA-03 (NF6) 30 March 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Automatic Non-freeze Valve NF6 Copyright 2015 by TLV CO., LTD. All rights

More information

Hydrostatic Pressure Testing

Hydrostatic Pressure Testing General An experienced or qualified person will be put in charge of hydro and should meet with the supervisor in charge of the job prior to test. Customer expectations should be clarified prior to beginning

More information

// ADapters GUIDelines

// ADapters GUIDelines // ADapters GUIDelines ADAPTER SELECTION Selection of an appropriate ALFAGOMMA adapter for a given application depends on the fluid system operating parameters listed below and the tube material and wall

More information

Installation and Use Manual

Installation and Use Manual Installation and Use Manual EMASMB & LMASMB Surface Mount Bottle Filling Stations Model EMASMB IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL.

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE MODELS RV-1 RV-2 RV-2CP RV-3 DRAWING NUMBERS AD017A[ ] AD018A[ ] AD020A[ ] AD282BO MANUAL NUMBER IOM-033 REVISION Rev. E, 3/28/2016 TABLE

More information

v. Size shall be specified on drawings.

v. Size shall be specified on drawings. SPECIFICATION FOR VACUUM INSULATED PIPING Part 1 General 1. Submittals a. After award of contract and before executing any manufacturing, shop drawings and specifications shall be submitted to the customer

More information

corporation For Technical Support... To Order Parts... Call: Fax: Call: Fax:

corporation For Technical Support... To Order Parts... Call: Fax: Call: Fax: c User Manual -osition Regulator 6604 and Kit 6844959 his manual provides installation and operator instructions for Cascade's -osition Regulator. he Regulator enables up to four pressure selections, allowing

More information

SERVICE INSTRUCTIONS PVWJ A-FRAME PUMPS -011/-014/-022 FOR TYPE P-1NN AND P-LNN PRESSURE COMPENSATING CONTROLS

SERVICE INSTRUCTIONS PVWJ A-FRAME PUMPS -011/-014/-022 FOR TYPE P-1NN AND P-LNN PRESSURE COMPENSATING CONTROLS Bulletin 947633 SERVICE INSTRUCTIONS PVWJ A-FRAME PUMPS -011/-014/-022 FOR TYPE P-1NN AND P-LNN PRESSURE COMPENSATING CONTROLS OILG0250 PURPOSE OF INSTRUCTIONS Figure 1. Typical Oilgear Type P-1NN and

More information

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material Series K Clean one-touch fittings For blowing Recommended applicable olyolefin: Series T Tubing material Soft polyolefin: Series TS Tubing O.D. ø, ø, ø, ø, ø olyurethane Series TU, Nylon Series T, and

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER MODEL F-4 DRAWING NUMBERS AD042C[ ] AD054C[ ] MANUAL NUMBER IOM-046 REVISION Rev. F, 4/23/2018 TABLE OF CONTENTS SAFETY 3 1. PRODUCT

More information

Model MC Circuit Setter Hose Kits Supply Valve Options: Ball Valve, UBY

Model MC Circuit Setter Hose Kits Supply Valve Options: Ball Valve, UBY Model MC Circuit Setter Hose Kits Supply Valve Options: Ball Valve, UBY Model MC Circuit Setter Description: Circuit Setter Balance Valves are precision engineered valves which function as precise system

More information

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6 COMMON PRECAUTIONS Page 1 of 6 These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution",

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

Flexible hoses - Non-metallic materials

Flexible hoses - Non-metallic materials CLASS PROGRAMME Type approval DNVGL-CP-0183 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Materials : Stainless steel ASTM A351 CF8M

Materials : Stainless steel ASTM A351 CF8M Certificat 3.1 Size: Ends : Min Temperature : Max Temperature : DN 15 to DN 200 PN16 Flanges R.F. - 20 C + 200 C Max Pressure : 16 Bars Specifiations : Removable stainless steel filter Bolted bonnet with

More information

Introduction. Key features of the Viper Maxi MKII WRL include:

Introduction. Key features of the Viper Maxi MKII WRL include: Page 1 Index Page 2 Viper Introduction... 3 The Viper Wire Rope Lubricator Kit components.... 4 Viper Kit components assembled and numbered.. 5 Assembly instructions... 6-8 Ratchet Strap instructions.

More information

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A. Gas Lines Technical Manual Sumitomo (SHI) Cryogenics of America, Inc. 1833 Vultee Street Allentown, PA 18103-4783 U.S.A. Revision F: April 2008 261320A TABLE OF CONTENTS Page DESCRIPTION...1 SPECIFICATIONS...2

More information

Cleaning. Introduction Page

Cleaning. Introduction Page Introduction Page Intro... -2 Creamery/Packing Washdown... -3 Washdown 1000... -4 Washdown 1250... -5 Supraforce... -6 Pressure Washer... -7 Concord Sandblast... -8 EATON Industrial Hose and Tubing Master

More information

SD67 HYDRAULIC SPIKE DRIVER

SD67 HYDRAULIC SPIKE DRIVER SD67 HYDRAULIC SPIKE DRIVER USER MANUAL Safety, Operation and Maintenance 2014 Stanley Black & Decker, Inc. New Britain, CT 06053 U.S.A. 17488 1/2015 Ver. 8 2 SD67 User Manual TABLE OF CONTENTS SAFETY

More information

Portable Hydrostatic Electric Test Pump. Procedure Manual. Dixon 800 High Street Chestertown, MD Fax: dixonvalve.

Portable Hydrostatic Electric Test Pump. Procedure Manual. Dixon 800 High Street Chestertown, MD Fax: dixonvalve. Portable Hydrostatic Electric Test Pump Procedure Manual Dixon 800 High Street Chestertown, MD 21620 800-355-1991 Fax: 800-283-4966 dixonvalve.com Dixon's Portable Electric Hydrostatic Test Pump (E.T.P.)

More information

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below. Page 1 of 15 Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below. Model Number A25-XXXX-3.6K Series A40-XXXX-3K Series A40X-XXXX-3.6K Series A60-XXXX-3K

More information

Pressure Relief Device Investigation Testing Lessons Learned

Pressure Relief Device Investigation Testing Lessons Learned Pressure Relief Device Investigation Testing Lessons Learned 2018 General Meeting Presentation Prepared by: Joseph F. Ball, P.E. Overview National Board Investigation Testing Process Summary of Results

More information

DI-DRO ADVANCED FORMING SYSTEMS

DI-DRO ADVANCED FORMING SYSTEMS DI-DRO ADVANCED FORMING SYSTEMS WE PARTNER WITH YOU We partner with you to provide force-generating products and solutions to lower your costs and increase your productivity in the forming of manufactured

More information

1. CONDITIONS FOR USE 2. SAFETY

1. CONDITIONS FOR USE 2. SAFETY 1. CONDITIONS FOR USE This micro abrasive blaster may only be operated: Indoors; Below 6500 ft above sea level altitude; Ambient air temperature between 40-105 F (5-40 C); Maximum relative humidity of

More information

RD(H)20/25 Pressure-Reducing Regulator User Manual

RD(H)20/25 Pressure-Reducing Regulator User Manual RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be

More information

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691 THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

REV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI

REV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI REV0709 Parts List Hydraulic Cylinder Model 10312 MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER Max. Capacity: 55.2 Tons at 10,000 PSI REV0709 Item No. Part No. No. Req d Description 1 10606

More information

Instructions for using TSI Model mm or 8025-CEN Fit Test Adapter Kit

Instructions for using TSI Model mm or 8025-CEN Fit Test Adapter Kit Instructions for using TSI Model 8025-40mm or 8025-CEN Fit Test Adapter Kit Kit Contents: Qty. Description 1 Adapter Assembly 50-ft 3/16-in OD 1/8-in ID PVC Tubing* 200 Suction Cups* 200 Clips* 1 Scissor

More information

Auto EVAP Quick Start Guide

Auto EVAP Quick Start Guide Auto EVAP Quick Start Guide Pg. 13 Note: Never directly hit or drop the leak detector on the CO2 sensor tip, this will cause the sensor to become damaged! Do not get Leak Seeker Solution directly on the

More information

BLADDER CARE INSTRUCTIONS

BLADDER CARE INSTRUCTIONS BLADDER CARE INSTRUCTIONS BLADDER REPLACEMENT ACCUMULATOR PRECHARGING ACCUMULATOR PRECHARGE MAINTENANCE ACCUMULATOR COMMISSIONING (For 3000, 4000, 5000, 6000 and 6500-psi Accumulators) (Does not apply

More information

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION TO AVOID POSSIBLE INJURY Warning: Always consider any accumulator to contain pressure until proven

More information

Carter Option X Valve connector assembly. Maintenance manual

Carter Option X Valve connector assembly. Maintenance manual Carter Option X Valve connector assembly Maintenance manual Table of contents Description Page 1.0 Introduction... 3 1.1 Safety equipment and procedure... 3 1.2 Maintenance safety alerts... 3 2.0 Equipment

More information

SEMPEO SQA Unit Code FP2P 04 Maintaining fluid power equipment

SEMPEO SQA Unit Code FP2P 04 Maintaining fluid power equipment Overview This standard covers a broad range of basic fluid power maintenance competences which will prepare you for entry into the engineering or manufacturing sectors, creating a progression between education

More information

About SPK-Rifeng Gas

About SPK-Rifeng Gas About SPK-Rifeng Gas Rifeng Gas systems are New Zealand s most popular multilayer gas system. The multilayer pipe has an inner layer of aluminium with Pex either side making it a flexible, strong and oxygen

More information

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Product documentation Directly controlled Operating pressure pmax: Flow rate Qmax: 700 bar 8 lpm D 3726 02-2016-1.3 by HAWE Hydraulik SE.

More information

SCOPE OF WORK. The Repair of the Mobile Harbour Crane leaking Luffing Cylinder

SCOPE OF WORK. The Repair of the Mobile Harbour Crane leaking Luffing Cylinder EAST LONDON MULTI-PURPOSE TERMINAL Document Title: SCOPE OF WORK Scope Of Work Title: The Repair of the Mobile Harbour Crane leaking Luffing Cylinder TPT MHC luffing cylinder repair 1 1. BACKGROUND East

More information

OCEAN DRILLING PROGRAM

OCEAN DRILLING PROGRAM BIH OCEAN DRILLING PROGRAM www.oceandrilling.org Scientifi c Application Packers A packer is an inflatable rubber element that inflates to seal the annular space between the drill string and the borehole

More information

GM-7000 Series CE Approved Gas Control Valve

GM-7000 Series CE Approved Gas Control Valve Installation Instructions GM-7000 Issue Date November 9, 2012 GM-7000 Series CE Approved Gas Control Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing

More information

BUTTERFLY VALVES Series 800

BUTTERFLY VALVES Series 800 BUTTERFLY VALVES Series 800 WARNING Before proceeding read ALL instructions and become familiar with the equipment and associated drawings. Follow ALL applicable safety regulations and codes for pressurized

More information

VF80 HYDRAULIC VENTILATING FAN. Safety, Operation and Maintenance Stanley Black & Decker, Inc. New Britain, CT U.S.A /2013 Ver.

VF80 HYDRAULIC VENTILATING FAN. Safety, Operation and Maintenance Stanley Black & Decker, Inc. New Britain, CT U.S.A /2013 Ver. VF80 HYDRAULIC VENTILATING FAN Safety, Operation and Maintenance USER MANUAL 2012 Stanley Black & Decker, Inc. New Britain, CT 06053 U.S.A. 07193 1/2013 Ver. 4 TABLE OF CONTENTS SAFETY SYMBOLS...4 SAFETY

More information

Irrigation System Winterization and Pressurization Procedures

Irrigation System Winterization and Pressurization Procedures Irrigation System Winterization and Pressurization Procedures Introduction Any time that an irrigation system is filled and pressurized, or when the system is drained and water flushed from the system,

More information

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg) Form No. 102897 Operating Instructions for: HB443 HB444 HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg) Definition: A devise that raises the inlet pressure to

More information

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Installation Troubleshooting Maintenance Instructions Installation / Start-up Model ZW207 Installation Troubleshooting Maintenance Instructions Installation / Start-up NOTE: Flushing of all pipe lines is to be performed to remove all debris prior to installing valve. 1. For making

More information

User Information Sheet 024

User Information Sheet 024 User Information Sheet 024 November 2010 PREPARATION, INSTALLATION, INSPECTION, TESTING AND MAINTENANCE OF RUBBER HOSES, UP TO AND INCLUDING 76 mm INTERNAL DIAMETER IN ACCORDANCE WITH BS EN 1762. 1 Introduction.

More information

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve Installation Instructions BGA Series Issue Date October 3, 2017 BGA158, BGA171 and BGA110 Series Shutoff Gas Valve Applications The BGA Series shutoff gas valve is an electrically operated gas valve that

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSURE PUMP To minimize vibration, it is best to build brackets on the motor itself, similar to alternator brackets. Use cardboard to construct a pattern first before making

More information

ASSEMBLY & USE MANUAL

ASSEMBLY & USE MANUAL DRAFT BEER DISPENSER ASSEMBLY & USE MANUAL - Stout Beers SAFETY FIRST! Read instructions completely Mixed gas can be dangerous. Flush chemical out of beer hose completely before re-tapping keg. Micro Matic

More information

49004 Relief Pressure Check Kit for H8508 Series and HW1 Series Impact Wrenches

49004 Relief Pressure Check Kit for H8508 Series and HW1 Series Impact Wrenches SERVICE DATA SHEET 49004 Relief Pressure Check Kit for H8508 Series and HW1 Series Impact Wrenches Read and understand all of the instructions and safety information in this manual before operating or

More information

4400 TwinHybrid Gas Seal

4400 TwinHybrid Gas Seal 4400 TwinHybrid Gas Seal EQUIPMENT PREPARATION MECHANICAL SEAL INSTALLATION INSTRUCTIONS 1 2 200.005" 0,13 mm 125 µ" 3,2 µm R a 3 4 32 µ" 0,8 µm R a 1000 ±.002" 0,05mm CAUTIONS These instructions are general

More information