210 & 220 series gas pressure regulators for industrial applications

Size: px
Start display at page:

Download "210 & 220 series gas pressure regulators for industrial applications"

Transcription

1 ULLETIN MS / & 220 series gas pressure regulators for industrial applications 210 Series

2 Dimensions and Spring Ranges D E D E DIMENSIONS Model and Illustration Number Pipe Size Diameter Dimensions D E 210D 1 1x1 1 1/4 x 1 1/4 1 1/2 x 1 1/2 7 in. 178 mm 8 7/8 in. 225 mm 3 5/8 in 92 mm 2 7/16 in. 62 mm 3 7/8 in. 98 mm 5 1/2 in. 140 mm 210E 1 210G 1 1 1/2 x 1 1/2 2 x 2 2 1/2 x 2 1/2 3 x 3 210J 1 4 x 4 9 1/8 in. 232 mm 13 7/16 in. 341 mm 18 in. 457 mm 11 1/4 in. 286 mm 16 1/16 in. 408 mm 24 3/16 in. 615 mm 4 5/16 in. 110 mm 6 1/8 in. 156 mm 10 7/16 in. 265 mm 2 5/16 in. 59 mm 4 1/4 in. 105 mm 5 7/16 in. 138 mm 5 3/4 in. 146 mm 8 1/8 in. 206 mm 9 1/2 in. 241 mm 7 5/8 in. 194 mm 10 3/8 in. 265 mm 13 3/4 in. 349 mm SPRING RNGE SELETION HRT (inches w.c.) For additional information see ulletin MP2012 Model Number Standard* Plated rown Orange Green d Plt Pink Violet lue Red Yellow lack 210D 1 to to 8 5 to 15 2 to 5 3 to 8 4 to 12 5 to to to to E 4 to 8 5 to 15 2 to 5 3 to 8 4 to 12 5 to to to to G 4 to 8 5 to 15 2 to 5 3 to 8 4 to 12 5 to to to to J 3 to 8 4 to 12 5 to to to to 42 *Factory set at 4.0 w.c.

3 210 series spring loaded models PITIES to FH EMERGENY EXPOSURE psi INLET PRESSURES to 10 psi OUTLET PRESSURE w.c. to 42 w.c. The 210 series is a lock-up type regulator and complies with codes using the specification. The 210 series has been designed for maximum control functions in an easy-to-use package. For gasfired boilers, steam generators, industrial furnances, ovens and similar high demand equipment. alanced valve design eliminates the inlet pressure effect acting on the valve. Regulating stability is improved and hunting tendencies reduced by the use of dampening mechanisms in both the breather outlet and sensing tube. You get precise regulation over a broad range of pressures and flow rates with a Maxitrol 210, including zero governor application. Housings of the 210D, E & G models are of high-strength aluminum alloy. The housings are reinforced with webs for maximum strength. The 210J models are of cast iron and steel construction with 125 pound flange connections..... Internal parts are cast or machined from corrosion resistant metals or are electro plated. Diaphragms are of the finest quality synthetic coated fabrics. The regulators are painted providing a protective coating if used out-of-doors. for pipe size, make sure regulator is not more than one size smaller or one size larger than manifold pipe size. For zero governor applications, a counterspring is mounted beneath the valve. maximum inlet pressure of 5 psi is recommended. Outlet pressure may be adjusted from -1.0 w.c. to +1.5 w.c. The Maxitrol 210 is designed to operate as a zero governor in the normal upright position. SENSING TPS VILLE Tap locations are available for downstream sensing, cross connections, and differential control. Four convenient locations can be tapped and plugged for measuring pressure. Vertical vent tapped - 3/8 NPT on 210D, 3/4 NPT on 210E, G & J 210 series industrial regulators are intended for use with all fuel gases. mbient temperature limits are F to F. Maximum emergency exposure pressure is 25 psi. t this pressure, the regulator will suffer no internal damage but it may not provide accurate regulation. The regulator should be mounted in an upright position in a horizontal pipe run. Gas flow must be oriented to arrow on bottom casting. When selecting. Internal sensing #7 furnished as standard.. Remote sensing tap #5.. Remote sensing tap #6. D. Outlet pressure tape #2. #1 on side opposite. E. Inlet pressure tap #4. #3 on side opposite.

4 apacities for spring loaded models UI FEET PER HOUR (0.64 sp gr gas) Inlet Pressure D 1 2,400 1,900 3,100 1,300 2,700 3,800 2,200 4,300 2,900 3,900 2,200 2,700 4,600 1,900 4,100 3, D 1-1/4 3,000 2,400 3,905 1,700 4,700 2,700 4,200 5,300 3,700 4,900 2,700 4,200 5,700 2,400 5,200 4, D 1-1/2 3,100 2,500 1,800 3,600 2,800 4,400 5,600 3,800 5,100 2,800 4,400 3,600 2,500 5, E 1-1/2 4,450 6,300 3,650 5,750 7,500 2,550 5,150 7,050 8,500 4,050 6,300 7,950 10,450 5,450 7,250 9,950 4,050 6,300 9,250 5,150 8,550 3,650 7,700 10,250 10,250 10,250 10,250 6,800 9,600

5 UI FEET PER HOUR (0.64 sp gr gas) Inlet Pressure E 2 5,150 7,250 4,200 6,650 8,650 2,950 5,950 8,150 9,850 4,700 7,250 9,150 6,300 8,400 11,500 4,700 7,250 10,700 5,950 9,850 4,200 8,900 11,850 7,850 11, G 2-1/2 10,400 14, ,500 13,410 17,500 16,400 19,900 9,500 14,700 18,500 12,750 16,950 23,250 9,500 14,700 21,600 19,900 8, ,850 22, G 3 11, , ,300 6,600 13,200 18,100 10,450 16,200 20, ,700 10,450 16,200 23,800 13,200 21,900 9,350 19,800 26,400 17,450 24, J 4 20,800 29, ,000 19,000 29, , ,000 29,420 43,350 39, ,800 4

6 Pressure Drop SPRING LODED DESIGN Flow Rate FH 500 1,000 1,500 2,000 2,500 3,000 5,500 7,500 8,500 9,000 9,500 11,000 13, ,000 22, , Values expressed in inches w.c. 210D 210E 210G 210J 1 1 1/4 1 1/ / /2 3 4 NOTE: The maximum capacities for the different models listed on the capacity chart and represented by the heavy line on the pressure drop table are values at which these controls have been certified by the.g.. (except for the 210J)

7 220 series pilot loaded models NOT.G.. ERTIFIED PITIES to FH EMERGENY EXPOSURE psi INLET PRESSURES to 10 psi OUTLET PRESSURE psi to 5 psi The 220 series, utilizing a servo-operated design rather than the more conventional spring-loaded design, delivers higher outlet pressure than the spring loaded models. The main diaphragm on the Maxitrol 220 is loaded with gas pressure rather than with a spring. This gas pressure is precisely controlled by a small pilot regulator in the upper housing. When the regulated outlet pressure of the pilot regulator is changed, by spring adjustment, the outlet pressure of the main regulator will change proportionately. Outlet pressure adjustments are readily made by first removing the hood of the Maxitrol 220. Then remove the cap atop the pilot regulator, which exposes the adjusting screw, and adjust to desired pressure. Three positions can be tapped and plugged for making inlet or outlet pressure readings. The fourth position is used to supply inlet pressure to the pilot regulator. Remote sensing is also available. 220 series industrial regulators are intended for use with all fuel gases. The regulator will perform most accurately when mounted in an upright postion in a horizontal pipe run. Gas flow must be oriented to arrow on regulator. When selecting for pipe size, make sure regulator is not more than one size larger or smaller than manifold pipe size. Single vent, equipped with model 1206 vent limiting orifice, is located in upper housing. mbient temperature limits are F to F. Maximum emergency exposure pressure is 25 psi. t this pressure the regulator will suffer no internal damage but it may not provide accurate regulation. Two outlet pressure adjustment springs are available. R (K spring) psi to 3 psi R (L spring) psi to 5 psi

8 ',1Ã(1Ã,62Ã Pressure drop and dimensions PILOT LODED DESIGN Flow Rate FH 1,000 2,000 3,000 9, , Values expressed in inches w.c. 210D 210E 210G 210J 1 1 1/4 1 1/ / / NOTE: Do not exceed 36 pressure drop when determining acceptable capacities at which these controls may be used. Under some conditions these limits may be surpassed, but only after consultation with Maxitrol ompany. (NOT.G.. ERTIFIED) DIMENSIONS Model 220D 220E 10-3/ / / /8 220G 220J 14-3/4 20-1/2 13-1/ /8 13-7/8 copyrighted publication of Maxitrol ompany Telegraph Rd., P.O. ox 2230 Southfield, MI U.S Fax European Representatives Warnstedter Strasse Thale, Germany Fax Industriestrasse Senden, Germany Fax

Gas Pressure. Regulators Catalog. For Industrial Engines and Generator Sets. 2011, Maxitrol Company. All Rights Reserved.

Gas Pressure. Regulators Catalog. For Industrial Engines and Generator Sets. 2011, Maxitrol Company. All Rights Reserved. Gas Pressure Regulators Catalog For Industrial Engines and Generator Sets 1 GAS PRESSURE REGULATORS For Industrial Engines and Generator Sets Service and or installation must be performed by a trained,

More information

Service and installation must be performed by a trained/experienced service technician.

Service and installation must be performed by a trained/experienced service technician. CATALOG Service and installation must be performed by a trained/experienced service technician. All products used with combustible gas must be installed and used strictly in accordance with the instructions

More information

CATALOG. 2 nd Edition

CATALOG. 2 nd Edition CATALOG 2 nd Edition Service and installation must be performed by a trained/experienced service technician. All products used with combustible gas must be installed and used strictly in accordance with

More information

North American 7337A/B/C-4 High Pressure Gas Regulators

North American 7337A/B/C-4 High Pressure Gas Regulators Combustion North American A/B/C-4 High Pressure Gas Regulators Bulletin A/B/C-4 A-4, B-4 and C-4 Regulators reduce high gas supply pressures to practical use levels. Since capacities will vary with the

More information

Noth American 7347 High Pressure Gas Regulators

Noth American 7347 High Pressure Gas Regulators Combustion Noth American 7347 High Pressure Gas s Bulletin 7347 7347 s reduce high gas supply pressures to practical use levels. Since capacities will vary with the pressure drop across the regulator (see

More information

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG A C E D SB-8520.2 1800CPB2 Service Regulators Maximum Inlet 125 PSIG AMC Quality System QMI is Accredited by: C R E D I T ISO 9001 Certified Certificate #006697 R E ANSI RAB G I S T R A R Dutch Council

More information

Gas Pressure Regulators. 3rd Edition

Gas Pressure Regulators. 3rd Edition Gas Pressure Regulators CTLOG 3rd Edition Service and installation must be performed by a trained/experienced service technician. ll products used with combustible gas must be installed and used strictly

More information

North American 7339 High Pressure Gas Regulators

North American 7339 High Pressure Gas Regulators Combustion North American 7339 High Pressure Gas Regulators Bulletin 7339 7339 Regulators reduce high gas supply pressures to practical use levels. Since capacities will vary with the pressure drop across

More information

GAS PRESSURE REGULATORS AND FILTERS.

GAS PRESSURE REGULATORS AND FILTERS. GAS PRESSURE REGULATORS AND FILTERS R www.mertikmaxitrol.com WARNING Service and installation must be performed by a trained/experienced service technician. All products used with combustible gas must

More information

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax 6R STANDARD REGULATOR COMPACT REGULATOR 496 Phone 7.63.888 Fax 7.63.690 6R AND 496 REGULATORS General Information The Model 6R and 496 Compact Regulator (CR) are designed to deliver reliable and safe regulation

More information

Ratio Regulator Zero Governor. FRG/6 Series

Ratio Regulator Zero Governor. FRG/6 Series Ratio Regulator Zero Governor FRG/6 Series CSA Certified ANSI Z21.18 / CSA 6.3 CSA Requirement # 5.01 Zero Governor and Gas/Air Regulator File # 157406 US and Canadian Models FRG 705/6 FRG 707/6 FRG 710/6

More information

1800CPB2 Pilot-Loaded Service Regulators

1800CPB2 Pilot-Loaded Service Regulators 1800CPB2 Pilot-Loaded Service Regulators Technical Bulletin www.elster-americanmeter.com Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................

More information

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP

More information

1800CPB2 Service Regulators

1800CPB2 Service Regulators SB 8520.5 1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................ 4-6 1-1/4" Models,

More information

Model 1800 PFM Series Regulator. Technical Bulletin

Model 1800 PFM Series Regulator. Technical Bulletin Model 0 PFM Series Regulator Technical Bulletin Model 0 PFM Series Regulator 0 Elster American Meter The 0 PFM Series regulators are designed to control natural gas, air, nitrogen, carbon dioxide, propane

More information

Service and installation must be performed by a trained/experienced service technician.

Service and installation must be performed by a trained/experienced service technician. CATALOG DRAFT 09.18.2013 Service and installation must be performed by a trained/experienced service technician. All products used with combustible gas must be installed and used strictly in accordance

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 1, 01 VGG VGD0 VGD0 Description Only when assembled to Series SKP actuators

More information

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),

More information

1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG

1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG SB-8506. B Service Regulators Maximum Inlet Pressure 5 PSIG Measurement Engineers Since 86 www.americanmeter.com B Service Regulators General Information The American Meter Series B pressure regulator

More information

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes DS-G-REG-13-43-0812-01-A* Model 243-RPC Pilot Operated Regulators Installation and Maintenance Instructions Rugged, Reliable with Value-added Features Genuine, pilot-operated regulators use the same relay

More information

North American Orifice Metering System

North American Orifice Metering System Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual

More information

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators Line Pressure Regulators @ - c - e G) t,5 ii:i! 1rlr1t APPLICATION NOTES 1rlr1t A. The Governor regulator is ANSI Z21.80a and ANSI Z21.18 certified for vent limited installations (indoor installations

More information

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators Line Pressure Regulators @ - c - e G) t,5 ii:i! 1rlr1t APPLICATION NOTES 1rlr1t A. The Governor regulator is ANSI Z21.80a and ANSI Z21.18 certified for vent limited installations (indoor installations

More information

SR100 Series Service Regulators. Technical Bulletin

SR100 Series Service Regulators. Technical Bulletin SR00 Series Service Regulators Technical Bulletin Model SR00 Series Regulator 0 Elster American Meter The compact, high capacity SR service regulator is designed for residential or light commercial/industrial

More information

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series Gas Appliance Pressure Regulators with integrated gas filter FRI/6 Series CSA Certified ANSI Z21.18 / CSA 6.3 Gas Appliance Pressure Regulator File # 1135455 EU Gas Appliance Directive EN 88 CE-0087 AU

More information

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators Product Line Brochure J0B Effective Date 2/01 Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators P R O D U C T L I N E O V E R V I E W Regulator

More information

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series Gas Appliance Pressure Regulators with integrated gas filter FRI/6 Series CSA Certified ANSI Z21.18 / CSA 6.3 Gas Appliance Pressure Regulator File # 1135455 EU Gas Appliance Directive EN 88 CE-0087 AU

More information

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze

More information

GAS SUPPLY DESIGN GUIDE

GAS SUPPLY DESIGN GUIDE GAS SUPPLY DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing Boilers BENCHMARK Series Gas-Fired Boilers For models: BMK750 to BMK6000 Last Update: 06/20/2014 PR1 06/20/14

More information

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7 Models 461-S, 461-8S and 461-12S Regulators R-1330 Rev. 7 461-S, 461-8S and 461-12S Regulators The Sensus Models 461-S, 461-8S and 461-12S are balanced valve, spring type regulators designed for distribution

More information

1800C and 1800C-HC Service Regulators

1800C and 1800C-HC Service Regulators SB 855.9 800C and 800C-HC Service Regulators Maximum Pressure 5 Table of Contents 800C Regulator Information...................... 800C-HC Regulator Information.................. 800C and 8C Service Regulators...............

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Type R622 Pressure Reducing Regulator

Type R622 Pressure Reducing Regulator Type R622 Pressure Reducing Regulator June 2010 Compact Design Protective Inlet Screen High Capacity Internal Relief Light Weight W8806 Inlet and Outlet Pressure Gauge Taps Figure 1. Type R622 Pressure

More information

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series Gas Appliance Pressure Regulators and Line Pressure Regulators FRS../6 Series FRS 5... Series CSA Certified ANSI Z21.18 CSA 6.3 as a Gas Appliance Pressure Regulator ANSI Z21.80 CSA 6.22 (FRS/6 series

More information

T208VR Series Tank Blanketing Vacuum Regulator

T208VR Series Tank Blanketing Vacuum Regulator February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

LINE PRESSURE REGULATOR GUIDEBOOK 7TH EDITION

LINE PRESSURE REGULATOR GUIDEBOOK 7TH EDITION CERTIFIED LINE PRESSURE REGULATOR GUIDEBOOK 7TH EDITION 2 AND 5 PSI SYSTEMS 2 3 This Handbook contains information from national heating and plumbing ordinances or codes that may have been adopted or incorporated

More information

Certified LP/Propane Line Pressure Regulator Guidebook

Certified LP/Propane Line Pressure Regulator Guidebook 3rd Edition Certified LP/Propane Line Pressure Regulator Guidebook 2 & 5 PSI Systems 2 3 The specifications in this Handbook refer to Maxitrol line pressure regulators used in LP/Propane applications only.

More information

Slam Shut Valves SCN

Slam Shut Valves SCN Slam Shut Valves SCN SCN > Slam shut valves Introduction SCN is a compact safety device (SAV) which quickly intercept gas flow whenever the pressure under monitoring reaches a pre-set limits, or whenever

More information

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series Line Pressure Regulators Class I or Class II FRS 7../6 Series CSA Certified ANSI Z21.80 / CSA 6.22 as a 5 PSI Class I or Class II Line Pressure Regulator File # 1205910 NPT Threaded Versions FRS 705/6

More information

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1 NPT (Typ. Both Ends 2 Places) MODEL Float Control For Closed Tanks Accurate Liquid Level Control Fully Hydraulic Operation Simple Design, Easy Maintenance No Lubrication Necessary No Gears, No Mechanical Linkage Between Valve and Control

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

627 Series Pressure Reducing Regulators

627 Series Pressure Reducing Regulators 627 Series Pressure Reducing Regulators Introduction The 627 Series direct-operated pressure reducing regulators (Figure 1) are for low and high-pressure systems. These regulators can be used with natural

More information

MEGR-1627 Instruction Manual

MEGR-1627 Instruction Manual MEGR-1627 HIGH FLOW GAS REGULATOR Instruction Manual- Look Inside For: Description Installation Remote Vent Line Installations Startup and Adjustment Shutdown Maintenance Body Maintenance Procedures Diaphragm

More information

Line Pressure Regulators Class I or Class II. FRS 7../6 Series

Line Pressure Regulators Class I or Class II. FRS 7../6 Series Line Pressure Regulators Class I or Class II FRS 7../6 Series CSA Certified ANSI Z21.80 / CSA 6.22 as a 5 PSI Class I or Class II Line Pressure Regulator File # 1205910 NPT Threaded Versions FRS 705/6

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25

More information

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000 Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They

More information

Industrial Regulator Series 1800/2000

Industrial Regulator Series 1800/2000 E S 85. Industrial Regulator Series / M Quality System QMI is ccredited by: R E I T ISO 9 ertified R E NSI R G I S T R R utch ouncil for ccreditation Measurement Engineers Since 86 merican Meter Series

More information

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control Cash Valve Type G-4 Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases Issued - March 2001 CAVMC-0512-US-0609 ISO 9001 Certified Flow Control Description FIG 2042 - Bronze FIG 2043 - Bronze

More information

1805 Series Relief Valves

1805 Series Relief Valves Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion

More information

G96 Series BASOTROL Dual Operator Valve

G96 Series BASOTROL Dual Operator Valve Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without

More information

KC Series Gas Components and Supply Design Guide

KC Series Gas Components and Supply Design Guide Technical Bulletin KC Series Gas Components and Supply Design Guide GF-1030 General AERCO KC Series gas fired potable water heaters and boilers are modulating input devices that require an adequate volume

More information

CLASS TLP Pressure Reducing Valve

CLASS TLP Pressure Reducing Valve CLASS TLP Pressure Reducing Valve CLASS TLP Direct Acting Pressure Reducing Valve The Class TLP balanced direct acting pressure regulator is designed for use on installations that have varying inlet pressures

More information

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators Document No. 7649 VRD40.xxxUx ISO 9001 and 14001 REGISTERED FIRM Only with series SKPxx.xxxUx actuators Description

More information

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity

More information

RB 4000 Commercial & Industrial Regulator

RB 4000 Commercial & Industrial Regulator R 4000 ommercial & Industrial Regulator The R 4000 pressure regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants and all installations where accurate

More information

Pressure Regulator B-95

Pressure Regulator B-95 Pressure Regulator B-95 TYPE B WATER & AIR TYPE B INTERIOR WATER & AIR B SERIES VALVES DESTRIPTION The Cash Valve Series B pressure reducing and regulating valves are single seated, spring loaded, direct

More information

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve) Phone (toll-free): (888) 380-9660 Phone (local): (973) 340-9955 Fax: (973) 340-9933 Web: www.straval.com 21 Columbus Avenue Garfield, NJ 07026 Model PRS-07i Stainless Steel Low Pressure, In-Line Pressure

More information

Series 100 Slam Shut Valve. Technical Bulletin

Series 100 Slam Shut Valve. Technical Bulletin Series 100 Slam Shut Valve Technical Bulletin 02 Elster The Series 100 Slam Shut protects gas installations against overpressure conditions by automatically shutting off the gas flow. General Information

More information

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012 Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of

More information

Performance Literature for J48. Gas Pressure Regulators 2½ 6 Sizes. Catalogue

Performance Literature for J48. Gas Pressure Regulators 2½ 6 Sizes. Catalogue Catalogue and Performance Literature for J48 Gas Pressure Regulators 2½ 6 Sizes Catalogue General Information CS4807C Regulating Capacity Flow Capacity Figures 2½ & 3 DS4819A Flow Capacity Figures 4 &

More information

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

CSB400 Series Commercial / Industrial Pressure Reducing Regulators CSB400 Series Commercial / Industrial Pressure Reducing Regulators Bulletin 71.1:CSB400 April 2011 CSB400 SERIES PRESSURE REDUCING TYPICAL CSB403 WITH INTEGRAL TRUE-MONITOR TYPICAL CSB404 WITH INTEGRAL

More information

Type 299 Pressure Reducing Regulators

Type 299 Pressure Reducing Regulators Type 299 Pressure Reducing Regulators Fisher, Fisher-Rosemount, and Managing The Process Better are marks owned by Fisher Controls International, Inc. or Fisher-Rosemount Systems, Inc. All other marks

More information

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings BR-G-REG-13-30-03-02-A* 461-S, 461-8S and 461-12S Regulators Brochure Introduction The Sensus Models 461-S, 461-8S and 461-12S are balanced valve, spring type regulators designed for distribution and industrial

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

Rate of Flow Valve Series 120

Rate of Flow Valve Series 120 SPECIFICATIONS Rate of Flow Valve Series DIMENSIONS The OCV Series 120 Rate of Flow control valve is designed to control or limit flow to a predetermined rate, regardless offl uctuations in downstream

More information

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators 61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

1805 Series Relief Valves

1805 Series Relief Valves October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

SECTION I REGULATORS

SECTION I REGULATORS SECTION I REULATORS Applications Pressure Regulation for Steam Distribution Single Point or Multiple Use Applications Pressure Control for Steam Plants District Heating Systems Single Stage Reduction Stations

More information

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local

More information

Model 141-A Field Regulator. R-1311 Rev. 9

Model 141-A Field Regulator. R-1311 Rev. 9 Model 4-A Field Regulator R-3 Rev. 9 4-A Field Regulator The 4-A Field Regulator is for high pressure work such as feeding intermediate and small volume loads from gas transmission lines. Use this field

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65 Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG A C E D SB 8551.3 Model 1800 PFM Series Regulator For Constant Precise Fixed Factor Measurement From 0.5 to 30 G AMC Quality System QMI is Accredited by: C R E D I T ISO 900 Registered R E ANSI RAB G I

More information

Regulator from 1800 B series

Regulator from 1800 B series Regulator from 1800 B series Regulator from 1800 B series Measuring of industrial gases frequently requests a precise pressure regulation for the purpose of dosage and proccesing. UNIS FAGAS has two kinds

More information

Types S100K and S102K Pressure Regulators

Types S100K and S102K Pressure Regulators Instruction Manual Form 5624 Types S0K and S2K 01/01 Types S0K and S2K Pressure Regulators W7478-1 Figure 1. Types S0K and S2K Pressure Regulator Introduction Scope of Manual This manual provides instructions

More information

Gas Pressure Regulator HON 502

Gas Pressure Regulator HON 502 Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas

More information

ASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer

ASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer ASSE International Product (Seal) Listing Program ASSE 1063-2016 Performance Requirements for Air Valve and Vent Inflow Preventer Manufacturer: Contact Person: E-mail: Address: Laboratory: Laboratory File

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

First Stage Regulators

First Stage Regulators DOMESTIC First stage regulators are typically used to reduce tank pressure to an intermediate pressure, usually 5 to 10 PSI for further pressure reduction by a second stage regulator located closer to

More information

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls Type 1098-EGR and Type 1098H-EGR VL1000 FIELDVUE Pilot-Operated Valve Link Regulators Fisher Controls January 1982 Bulletin The Type 1098-EGR and Type 1098H-EGR regulators (figure 1) provide economical

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1 Instruction Manual 742 5/1/2009 Eclipse Ratio Regulators ES Series Version 1 Copyright Copyright 1997 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by federal regulation

More information

1800C & 1800C-HC Service Regulators

1800C & 1800C-HC Service Regulators SB-855.8 800 & 800-H Service Regulators Maximum Pressure 5 PSIG 800 Regulator Information General Information The merican Meter Series 800 pressure regulators are designed for natural gas applications

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! INLET PRESS TAP WHITE-RODGERS 36E93-304 Delay-Opening Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information

Bermad Pressure Reducing. Model: 42T

Bermad Pressure Reducing. Model: 42T Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel

More information

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation Size: inch / mm Every Ross Valve shall be hydrostatically tested for body integrity and tight seating

More information

C645A-E Pressure Switches

C645A-E Pressure Switches C645A-E Switches FEATURES PRODUCT DATA C645A,B,D,E GENERAL C645A,B with Window C645C The C645 pressure switches are safety devices used in positive-pressure or differential-pressure systems to sense gas

More information

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002 Installation Guide English May 2002 Type ACE97 Introduction This installation guide provides instructions for installation, startup, and adjustment. To receive a copy of the instruction manual, contact

More information

Installation Instructions

Installation Instructions 48011HW NATURAL GAS TO PROPANE CONVERSION KIT 58HDX, 359AAV, PG9YAB, PG9YAA Installation Instructions SAFETY REQUIREMENTS Installing and servicing heating equipment can be hazardous due to gas and electrical

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations Proven Technology. Superior Performance. Today s natural gas industry has a growing demand for operational excellence. Pilot-operated

More information

J48 Gas Pressure Regulator. Technical Bulletin

J48 Gas Pressure Regulator. Technical Bulletin J48 Gas Regulator Technical Bulletin J48 Gas Regulator 02 Elster The J48 is an industrial low pressure regulator suitable for a wide range of pressure reduction applications, including such OEM equipment

More information

Safety Cut-Off Valve HON 305

Safety Cut-Off Valve HON 305 Safety CutOff Valve HON 305 PRODUCT INFORMATION Serving the Gas Industry Worldwide SAFETY CUTOFF VALVE HON 305 Introduction, Application, Features, Technical Data Introduction The HON 305 is a safety cutoff

More information