LIST OF TRAFFIC DETAILS

Size: px
Start display at page:

Download "LIST OF TRAFFIC DETAILS"

Transcription

1

2 LIST OF TRAFFIC DETAILS No. of Sheets Detail TRAFFIC SIGNAL DESIGN & CONSTRUCTION STANDARD NOTES 3 TE-0 25 CONDUCTOR CABLE WIRING AND COLOR CODE 1 TE-CO FOUNDATION FOR SIGNAL POLE WITH BOLT DOWN BASE 2 TE-1 PEDESTAL POLE FOUNDATION 1 TE-2 M-I CABINET FOUNDATION WITH FOOT PAD (BACKUP POWER CABINET FOUNDATION) P-I CABINET FOUNDATION WITH FOOT PAD (STANDARD CONTROL CABINET FOUNDATION) 1 TE-3 1 TE-4 MAST ARM DESIGN DETAILS 5 TE-5 POLE MOUNTED VEHICULAR & PEDESTRIAN SIGNAL HEADS 2 TE-6 METRO STREET NAME SIGN MOUNTING 1 TE-7 PULL BOXES 2 TE-8 LOOP DETECTORS 3 TE-9 SCHOOL AREA SIGNAGE 2 TE-10 STEEL SIGN TUBING INSTALLATION 1 TE-11 STRIPING MATERIALS AND CROSSWALKS 3 TE-12 SIGHT DISTANCE REQUIREMENTS 3 TE-13

3 DRAFT\STANDARDS\TRAF-STD\TE-0.0.dwg STANDARD TRAFFIC SIGNAL C0NSTRUCTION STANDARDS CITY OF AURORA All traffic signals maintained by the City of Aurora must be constructed in accordance with the details shown on sheets TE-1 through TE-13 as well as the following: A) Cabinets and Cabinet Foundations 1) All conduits shall be cut off with no more than ½ inch extending above concrete base. 2) AC and DC conductors shall be in separate conduit. Communication lines shall be included with the DC cables. A separate 2 inch conduit shall be used for the power feed. 3) Cabinet ground rod shall be a 5/8 inch 8 foot copper rod located in the home run pull box. 4) Ground wire shall be a #6 AWG solid copper. 5) Power wiring shall be #6 AWG copper stranded and insulated, black for the hot and white for the neutral. Wiring shall be labeled indicating point of service. 6) Field wiring shall be terminated using insulated spade connectors, with a maximum of two (2) #14 AWG wires per connector. 7) All field wiring shall be labeled and color coded by phase and direction. This includes signal, pushbutton, detection, and opticom wiring. Communications line shall be labeled indicating the location of service (if applicable) and interconnect shall be labeled indicating destination. 8) All wiring shall be neat with adequate slack for rearrangements. 9) Cabinet base shall be level extending approximately 18 inches above and 18 inches below ground. 10) Cabinet shall be leveled so that the door opens freely without binding. 11) Cabinet shall be caulked around base with silicon caulk to make watertight. B) Pull boxes & Conduit 1) Pull boxes shall be set on a minimum of 8 inches of 3/4 inch crushed gravel for drainage. 2) Conduits in pull boxes shall be stubbed up a minimum of 4 inches above the gravel at a 90-degree angle from level and flush with each other. Conduit shall be cut off approximately 6 inches below the pull box lid. 3) Conduit shall be direct bore under existing roadway unless otherwise approved. Number & size to be per approved design plans, typ. 1 2" and 2 3" for intersection legs. Typical depth shall be 36" unless otherwise approved by the Traffic Engineer. All conduit to be Schedule 80. 4) Pull box cover bolts shall be in place and the drain holes for bolts shall be opened. 5) Pull boxes shall be one inch above and parallel to the ground except when installed in concrete or as field determined. 6) Pull boxes installed in concrete shall be flush with finished concrete and have expansion material around the outside of pull box. 7) Wire in pull boxes shall not be tangled or twisted. Wire shall be neat with a maximum of a 1-foot loop and be tagged and color coded, indicating direction and termination point. 8) A pull string shall be provided in all conduits. Any unused conduits shall be capped and have a locating line (metallic conductor) installed if the unused conduit does not parallel other populated conduit. 9) No wire splices shall be allowed in pull boxes, except for loops, which must be soldered and sealed with shrink tube. Loops shall be tagged and color coded with phase and direction. (see TE-9.3) 10) Any necessary cuts to a pull box shall be done with a cutting tool without structural damage to the pull box. 11) AC and DC conductors shall be in separate conduits. C) Wiring 1) Each pole shall have its own separate home run, with a minimum of 25-conductor IMSA signal cable. No splices shall be allowed between the cabinet and the destination pole. Wiring shall be terminated in accordance with attached color code (see TE-CO). 2) All signal wiring in pole bases shall be identified with phase taping by direction, per City color code. 3) Each push button shall be fed with a separate black 2 conductor shielded cable, continuous from cabinet to button. 4) A 4 conductor IMSA signal cable shall service each pedestrian (Walk / Don't Walk) head. 5) All holes for side of pole signal installation (to include pushbuttons) shall be drilled 1¼ inches and a rubber grommet installed. (no torch holes) 6) Wiring in hand holes shall have 12 to 18 inches of slack that can be pulled out for inspection or rearrangements. 7) Each signal head shall be fed with a 7 conductor IMSA signal cable. 8) Street lights shall be serviced by a 14/2 UF cable that must be continuous and without splices from each luminaire to the power source. Streetlight feed shall be in a separate 2" conduit and have separate pullboxes on each corner to isolate the streetlight circuit as much as possible. 9) Illuminated street name signs shall be serviced by a 14/2 UF cable (with ground) which must be continuous and without splices from the base of the signal pole to the power source. The power cable from the illuminated street name signs shall be spliced to the 14/2 UF cable in the hand hole at the base of the signal pole. (see TE-5.2) 1 of 3

4 DRAFT\STANDARDS\TRAF-STD\TE-0.1.dwg STANDARD TRAFFIC SIGNAL C0NSTRUCTION STANDARDS CITY OF AURORA All traffic signals maintained by the City of Aurora must be constructed in accordance with the details shown on sheets TE-1 through TE-13 as well as the following: C) Wiring (continued) 10) Loop detection lead in ("Homerun") wire shall be a 2-conductor, #14 AWG stranded tinned copper wire, polyethylene insulated twisted conductors with 100% shield coverage and stranded tinned copper drain wire. Wire shall have a chrome PVC jacket. Wire shall be Belden #8720 or approved equal. 11) AC and DC conductors shall be in separate conduits. 12) Video detection wiring shall be continuous from camera to control cabinet. No splices shall be allowed. D) Traffic Signal Poles and Mastarms 1) Traffic signal poles are typically furnished to the contractor by the City. In a case where signal poles are to be furnished as part of a traffic signal construction bid, poles shall meet current City standards and be approved by the Traffic Engineer prior to procurement. 2) Mastarm lengths shall at a minimum reach the center of the left-turn lane for each approach in the the case of single left-turn lane; or the lane line between the left-turn lanes in the case of dual left-turn lanes. In either case, the length of the mastarm shall be rounded up to the nearest 5 foot increment and indicated on the signal plan and quantities sheet accordingly. 3) Signal pole extensions and luminaire arms shall be furnished for all signal poles at an intersection unless there is an overhead obstruction such as a powerline and deviation is approved by the Traffic Engineer. 4) A typical intersection shall consist of one pole and mastarm for each approach. Multiple mastarms on a single pole shall not generally be allowed. E) Intersection Phasing/Signal Heads/Signage 1) Intersection phasing shall have phase Ø2 as either the northbound or eastbound through movement, whichever is the major street. Through movements are numbered as even phases (Ø4, Ø6, Ø8) clockwise around the intersection from phase Ø2. Left-turn phasing (where applicable) is denoted by odd numbered phases (Ø1, Ø3, Ø5, Ø7), with the following phase pairs (Ø2 Ø5, Ø4 Ø7, Ø1 Ø6, Ø3 Ø8). Unusual geometry or other conditions shall require phase approval by the Traffic Engineer. Phasing diagram shall be shown on design plans. 2) Signal heads shall be provided on both left and right poles for each direction to supplement overhead signal heads. The left side pole head shall match the leftmost overhead signal head and the right side pole head shall match the rightmost overhead signal head unless otherwise approved by the Traffic Engineer. 3) One signal head per lane, centered on the lane, shall be provided with the exception of dual left-turn lanes for which one signal head centered on the lane line between the two left-turn lanes shall be provided. Dedicated right turn lanes shall be provided with a regulatory R3-5R 30"x36" overhead sign centered on the lane in lieu of a signal head. Any deviation shall be approved by the Traffic Engineer. 4) City standard for left-turn displays shall be the Flashing Yellow Arrow (FYA) 3 section display for permissive only phasing; FYA 4 section display for protected/permissive phasing, and a 3 section RA-YA-GA display for full time protected only phasing unless otherwise approved by the Traffic Engineer. Determination of the appropriate display selection shall be made by the Traffic Engineer. 5) Dedicated left-turn lane(s) shall be provided with a regulatory R3-5L 30"x36" overhead sign or R3-5mod 48"x30" (dual left) sign placed to the right of the left-turn signal head. F) Additional Notes 1) On design plans, the lane configuration for each approach (e.g. left only, through-through-through/right) shall be shown by means of hollow arrows at the edge of the approach furthest from the intersection - these arrows are for informational purposes only and are not meant to indicate pavement markings. On the design plans, the major street shall be shown for 200' in advance of the intersection and the minor street for 150' in advance of the intersection for both directions. 2) Necessary pavement markings shall be shown as filled arrows in their appropriate locations. 3) Pedestrian movements shall be provided for all four directions of an intersection, accompanied by pedestrian heads, pushbuttons and crosswalks unless otherwise approved by the Traffic Engineer. 4) Flash program operations shall be shown on all design plans. 5) Any materials not provided by the City shall be submitted to the Traffic Engineer or designate for review and approval prior to procurement of said materials. 6) The City reserves the right to require successful demonstration of any proposed non-standard or unusual phasing or operation at its discretion. 2 of 3

5 TRAFFIC SIGNAL C0NSTRUCTION STANDARDS CITY OF AURORA F) Additional Notes (continued) 7) Once traffic signal contractor has begun work on traffic signal construction, all operations & maintenance responsibilities for the traffic signal and intersection shall shift to the contractor until such time as all work is complete and has been inspected and accepted in writing by Traffic Engineering and Operations. Additionally, the contractor shall provide a minimum one-year warranty for all work. 8) For rebuilds or modifications to existing signals, design plans shall include, at a minimum, one sheet reflecting existing conditions and one sheet reflecting proposed conditions. Additional sheets and information may also be required at the Traffic Engineer's discretion. 9) For new traffic signal construction, the signal shall be placed into flashing operation a minimum of 48 hours prior to the activation of full operation. Both flash and full turn-ons shall occur on Tuesdays, Wednesdays, or Thursdays only on non-holiday weeks only unless otherwise approved by the Traffic Engineer. For traffic signal rebuilds or modifications, changeovers from old equipment to new equipment shall only occur between 8:30am and 3:30pm on Tuesday, Wednesday, or Thursday only on non-holiday weeks only unless otherwise approved by the Traffic Engineer. 10) Any traffic signal or pedestrian indications that are under construction and are not active shall be covered with ORANGE bags until such time as they are placed into service. Any pedestrian pushbuttons that are under construction and not active shall have the associated signage placed blank side out and the buttons covered until such time as they are placed into service. Crosswalks shall not be marked at new traffic signal installations until such time as the traffic signal is placed into full operation but shall then be marked on the same day or as soon as possible afterward. Any deviation from the above must be approved by the Traffic Engineer. 11) For all new traffic signal installations punchlist inspection shall be scheduled and coordinated with Engineering, Inspections, and Operations. All punchlist items shall have been addressed and confirmed corrected and the traffic signal to be 100% complete prior to flash turn-on. The City will not assume ownership, maintenance, and operation of the new traffic signal until such time as the punchlist has been verified complete, the signal has been placed into full operation, and the signal has been formally accepted in writing by Operations. A minimum one-year warranty shall be provided for all new traffic signal installation work. Any deviation from the above must be approved by the Traffic Engineer. 12) Video detection (camera) placement and mounting type to be determined by the manufacturer and/or vendor for optimal location and performance of the product, subject to approval by the City of Aurora. This will be a vehicle lane approach specific determination. DRAFT\STANDARDS\TRAF-STD\TE-0.1.dwg 3 of 3

6 MAIN STREET #2 SOLID WHITE AC-RETURN #4 SOLID GREEN M.S. GREEN #5 SOLID ORANGE M.S. YELLOW #3 SOLID RED M.S. RED #6 SOLID BLUE M.S. L/T GREEN ARROW OR FYA #11 BLUE W/BLACK STRIPE M.S. L/T YELLOW ARROW OR FYA #14 GREEN W/WHITE STRIPE M.S. WALK #13 RED W/WHITE STRIPE M.S. DON'T WALK #19 BLUE W/RED STRIPE M.S. R/T GREEN ARROW OR FYA #18 ORANGE W/RED STRIPE M.S. R/T YELLOW ARROW OR L/T RED ARROW OR FYA #21 ORANGE W/GREEN STRIPE M.S. L/T FLASHING YELLOW ARROW FYA #20 RED W/GREEN STRIPE M.S. L/T RED ARROW FYA #9 GREEN W/BLACK STRIPE #10 ORANGE W/BLACK STRIPE #8 RED W/BLACK STRIPE #1 SOLID BLACK #12 BLACK W/WHITE STRIPE #15 BLUE W/WHITE STRIPE #16 BLACK W/RED STRIPE #7 WHITE W/BLACK STRIPE #17 WHITE W/RED STRIPE #22-25 SPARE CONDUCTORS SIDE STREET S.S. GREEN S.S. YELLOW S.S. RED S.S. L/T GREEN ARROW OR FYA S.S. L/T YELLOW ARROW OR FYA S.S. WALK S.S. DON'T WALK S.S. R/T GREEN ARROW OR FYA S.S. R/T YELLOW ARROW OR L/T RED ARROW OR FYA NOTE: ALL HAND HOLE TERMINATIONS SHALL BE IDENTIFIED AS FOLLOWS: RED NORTH ORANGE EAST GREEN SOUTH BLUE WEST YELLOW IDENTIFIES A PED YELLOW YELLOW IDENTIFIES A PUSH BUTTON WHITE IDENTIFIES A LEFT TURN DRAFT\STANDARDS\TRAF-STD\TE-CO.dwg PURPLE IDENTIFIES A RIGHT TURN BROWN IDENTIFIES SPARE CONDUCTORS FYA = FLASHING YELLOW ARROW #XX - DESIGNATES WIRE # ON STANDARD IMSA SPEC., 25 CONDUCTOR CABLE. FOR REFERENCE ONLY.

7 PROVIDE 1'-0" MIN LAP FOR TIES #5 TIE AT 30" DIA. CAISSONS: 10-#8 VERTICAL BARS AT 36" DIA. CAISSONS: 12-#9 VERTICAL BARS AT 42" DIA. CAISSONS: 12-#10 VERTICAL BARS 1-2" AND 3-3" DIA. PVC CONDUIT TO PULL BOX 3" CLR. ANCHOR BOLT CIRCLE DIAMETER VARIES WITH POLE TYPE INSTALL ANCHOR BOLTS (FURNISHED WITH POLE) PER MANUFACTURER'S TEMPLATE (FURNISHED WITH ORDER). ORIENT HOOKS SUCH THAT A CONCRETE PUMP HOSE CAN ACCESS THE BOTTOM OF THE EXCAVATION. ANCHOR BOLTS SHALL BE GALVANIZED AT THREADED ENDS IN ACCORDANCE WITH ASTM A-153. TRAFFIC SIGNAL FOUNDATION TOP VIEW GENERAL NOTES 1. THE STANDARD SIGNAL FOUNDATIONS SHOWN ON THIS DRAWING SHALL ONLY BE USED WITH SIGNAL PLANS APPROVED BY THE CITY OF AURORA. 2. ALL WORK SHALL BE CONDUCTED IN ACCORDANCE WITH CITY OF AURORA ROADWAY DESIGN AND CONSTRUCTION SPECIFICATIONS. 3. CAISSON CONCRETE SHALL BE CITY OF AURORA CLASS 1A, f' C = 4000 psi. 4. ALL REINFORCING STEEL SHALL BE PER AASHTO M31, GRADE 60, f Y = 60,000 psi. 5. ANCHOR BOLTS SHALL BE ASTM F1554 MODIFIED TO 55 ksi YIELD STRENGTH. ANCHOR BOLTS SHALL BE FURNISHED BY SIGNAL POLE MANUFACTURER. BOLTS SHALL BE GALVANIZED AT THREADED ENDS IN ACCORDANCE WITH ASTM A THE SIGNAL FOUNDATION DESIGN SHOWN ON THIS DRAWING ASSUMES THE MINIMUM SOIL CHARACTERISTICS AS WOULD BE TYPICALLY ENCOUNTERED IN AURORA WHICH ARE NOTED BELOW. IN THE EVENT THAT SOFT OR LOOSE SOIL CONDITIONS ARE ENCOUNTERED, A SITE SPECIFIC GEOTECHNICAL EVALUATION AND FOUNDATION DESIGN MAY BE NECESSARY. DRAFT\STANDARDS\TRAF-STD\TE dwg ASSUMED GEOTECHNICAL DESIGN PARAMETERS: SOIL DENSITY (~g) = 110 pcf for Cohesive (Clay) Soils; 115 pcf for Non-Cohesive (Sandy) Soils SOIL COHESION = 750 psf (for Cohesive Soils) E50 = 0.01 in/in (for Cohesive Soils) ANGLE OF INTERNAL FRICTION (Ø) = 30 (for Non-Cohesive Soils) HORIZONTAL MODULUS OF SUBGRADE REACTION (Ks) = 90 pci (for Non-Cohesive Soils) 7. IF THE FOLLOWING SITUATIONS ARE ENCOUNTERED DURING DRILLING, CONTACT THE CITY OF AURORA ENGINEER: (A) THE SOIL HAS A HIGH ORGANIC CONTENT OR CONSISTS OF SATURATED SILT OR CLAY (B) THE SITE WILL NOT SUPPORT THE WEIGHT OF THE DRILLING RIG (C) THE FOUNDATION SOILS ARE NOT HOMOGENEOUS (D) FIRM BEDROCK IS ENCOUNTERED (E) GROUNDWATER IS ENCOUNTERED TRAFFIC ENGINEER DIRECTOR OF PUBLIC WORKS DATE DATE 1 of 2

8 HEAVY HEX NUTS AND FLAT WASHERS. PLUMBING OF POLES SHALL BE ACCOMPLISHED BY ADJUSTING NUTS. BASE PLATE OF POLE (ASTM A-36) PULL BOX FINISHED GRADE SIGNAL POLE NON-SHRINK GROUT TO BE PLACED BETWEEN BASE PLATE AND TOP OF FOUNDATION 2" CLR. 24" #8 AWG INSULATED SOLID COPPER GROUNDWIRE CLAMPED TO GROUND ROD 1-2" AND 3-3" DIA. PVC CONDUIT ANCHOR BOLTS 5/8"x8'-0" COPPER CLAD GROUND ROD IN PULL BOX. AT 30" DIA. CAISSONS : 10-#8 VERTICAL BARS AT 36" DIA. CAISSONS : 12-#9 VERTICAL BARS AT 42" DIA. CAISSONS: 12-#10 VERTICAL BARS 3" CLR. 30", 36", OR 42" DIAMETER 4" #5 12"~P 4" LENGTH VARIES 12'-0" TO 19'-0" (SEE SIGNAL POLE FOUNDATION SCHEDULE) SIGNAL POLE FOUNDATION SCHEDULE MAST ARM LENGTH (FT) MAX. BOLT CIRCLE DIA. (IN) CAISSON DIA. (IN) CAISSON LENGTH (FT) 15 TO TO TO CONSTRUCTION NOTES TRAFFIC SIGNAL FOUNDATION ELEVATION DRAFT\STANDARDS\TRAF-STD\TE dwg 1. FOUNDATIONS SHOULD BE POURED 10 TO 20 DAYS PRIOR TO POLE INSTALLATION. 2. CAISSONS SHALL BE PLACED AGAINST UNDISTURBED EARTH. 3. CONCRETE SHALL BE VIBRATED. 4. A MINIMUM OF 3" CONCRETE COVER SHALL BE MAINTAINED AROUND THE STEEL CAGE. A MAXIMUM OF 4" OF COVER IS ALLOWED AT THE TOP OF THE CAGE. 5. LOOSE DIRT SHALL BE REMOVED FROM THE BOTTOM OF THE HOLE PRIOR TO POURING CONCRETE. 6. NO COLD JOINTS ARE ALLOWED IN CAISSONS. POUR CAISSONS CONTINUOUSLY TO FINISHED GRADE. 7. POLE FOUNDATION MAY ALTER IN DEPTH AND/OR DIAMETER, AS APPROVED BY THE CITY'S TRAFFIC ENGINEER. THE CITY SHALL APPROVE MODIFICATIONS NEEDED FOR THE CAISSONS DUE TO UNFORESEEN CONDITIONS. 8. BASE DIMENSIONS MAY VARY FROM THE STANDARD, BUT ONLY UPON APPROVAL BY THE CITY TRAFFIC ENGINEER. 9. THE BOLT CIRCLE DIAMETERS SHOWN REPRESENT THE MAXIMUM ANTICIPATED DIAMETERS REQUIRED AT THE SIGNAL POLE BASES FOR THE CORRESPONDING MAST ARM SPAN. TRAFFIC FIC ENGINEER DIRECTOR OF PUBLIC WORKS DATE DATE REV of 2

9 13 3/4" 4 1/2"O.D. POLE 24" (ROUND OR SQUARE) 13 3/4" GROUND ROD CONTROLLER OR FLASHER CABINET* TOP VIEW 12"-14.5" SLIP FITTER COLLAR BASE COLLAR ASSEMBLY (TYP) PEDESTAL POLE 4' 4 1/2"O.D. FINISHED GRADE PEDESTAL BASE 15 3/16" 2" BASE COLLAR ASSEMBLY (TYP) 24" ANCHOR BOLT (TYPICAL) 36" STUB OUT INSIDE PULL BOX 1-2" & 1-3" PVC CONDUIT 24" CLASS 1 CONCRETE GROUND ROD DRAFT\STANDARDS\TRAF-STD\TE-3.0.dwg FRONT VIEW * The foundation on this detail also applies to TE-6.2 Pole Mounted Vehicular & Pedestrian Signal Heads

10 36" 18" 18" 2-3", 1-2" PVC CONDUIT STUB OUT TO PULL BOX ANCHOR BOLT 2" PVC CONDUIT FOR POWER 13 1/2" 5 1/4" 24" 1) Foot pad may be eliminated per design or per Traffic Engineer's discretion. 1/2" PREMOLDED JOINT FILLER 5 1/4" FOOT PAD OR SIDEWALK (CLASS 1 CONCRETE) 30" FOOT PAD OR SIDEWALK TOP VIEW 1/2" CLASS I CONCRETE 3" PVC CONDUIT 18" MIN. FINISHED GRADE 36" 18" 24" 2" PVC CONDUIT SIDEWALK OR 6" MIN. FOOT PAD DRAFT\STANDARDS\TRAF-STD\TE-4.0.dwg STUB OUT TO PULL BOX FRONT VIEW SIDE VIEW

11 48" 3 11/16" 40 5/8" 3 11/16" 2-3" 1-2" PVC CONDUIT STUB OUT TO PULL BOX POWER USE ONLY 2" PVC CONDUIT 18 1/2" 8 3/4" 36" 1) Foot pad may be eliminated per design or at Traffic Engineer's discretion. ANCHOR BOLTS 8 3/4" 1/2" PREMOLDED JOINT FILLER FOOT PAD OR SIDEWALK (CLASS 1 CONCRETE) 30" FOOT PAD OR SIDEWALK 1/2" TOP VIEW 2" PVC CONDUIT CLASS I CONCRETE 18" MIN. FINISHED GRADE 36" 18" 24" SIDEWALK OR 6" MIN. FOOT PAD DRAFT\STANDARDS\TRAF-STD\TE-5.0.dwg 3" PVC CONDUIT (2) FRONT VIEW SIDE VIEW

12 0-2 RAKE WHEN FULLY LOADED 20'-0" 2% SLOPE 2% SLOPE DRAFT\STANDARDS\TRAF-STD\TE-6.1.dwg Notes: 1. Design parameters consistent with 2013 AASHTO Standard Specifications for Structural Supports for Highway Signs, Luminaires, and Traffic Signals 6th Edition year design life, Category II unless otherwise approved. 3. Finish galvanized to ASTM A Reference current version of City of Aurora Traffic Signal Structure Specifications for additional requirements. 1 of 5

13 NOMINAL 40' MOUNTING HEIGHT LUMINAIRE 14/2 TYPE UF CABLE FROM LUMINAIRE TO BASE OF POLE REMOVABLE CAP 2' 15' 10 HAND HOLE 12" TWO BRACKET TYPE ATTACHMENTS 17' MIN. HAND HOLE REMOVABLE CAP A U A R O R 37' 14/2 TYPE UF CABLE FROM SIGN TO BASE OF POLE 20'-0" SPLICE SIGN CABLE TO POWER CABLE IN HAND HOLE HAND HOLE 2% SLOPE 2% SLOPE 18" BASE PLATE DRAFT\STANDARDS\TRAF-STD\TE-6.2.dwg NOTES: 1. ILLUMINATED STREET NAME SIGN CABLE IS SPLICED TO 14/2 UF POWER CABLE IN HAND HOLE AT EACH POLE AS SHOWN. IN ADDITION, THE POWER CABLE FROM EACH POLE IS BROUGHT BACK TO THE ELECTRIC P. O. S. AND FUSED AT THAT POINT. 2. STREET LIGHT AND POLE EXTENSION ARE STANDARD. IF SITE- SPECIFIC CONDITIONS PRECLUDE POLE EXTENSION, A REMOVABLE CAP SHALL BE INSTALLED ON TOP OF THE POLE. 2 of 5

14 40" 40" 40" 40" OR A U A R O R See Note 4 17'-6" 2% SLOPE 2% SLOPE DRAFT\STANDARDS\TRAF-STD\TE-6.3.dwg Notes: 1. Condition shown indicates maximum loading for mastarms from feet in length. Actual length may vary by location 2. Reference current City of Aurora Traffic Signal Structure Specifications for specifics of loading surface areas and weights. 3. City standards requires heads to be centered on lanes with the exception of double left turn lanes, for which the head is centered on the lane line - lane widths and therefore head spacing may vary by location. 4. Although not shown on this detail, the typical installation will also include 2 each 3- or 4-section vehicle signal heads without backplate; 2 each pedestrian heads; and 2 each 9x12 pedestrian pushbutton frames and signage located on the pole below the mastarm plate -- see TE-6.1 for specifics. 3 of 5

15 Standard FYA Signal Head (Max FYA condition 4 section shown) 40" 40" 40" 40" 40" 40" 40" or NOMINALLY HORIZONTAL A U R O R A 5 section option See Note 4 17'-6" 2% SLOPE 2% SLOPE DRAFT\STANDARDS\TRAF-STD\TE-6.4.dwg Notes: 1. Condition shown indicates maximum loading for mastarms from feet in length. Actual length may vary by location 2. Reference current City of Aurora Traffic Signal Structure Specifications for specifics of loading surface areas and weights. 3. City standards requires heads to be centered on lanes with the exception of double left turn lanes, for which the head is centered on the lane line - lane widths and therefore head spacing may vary by location. 4. Although not shown on this detail, the typical installation will also include 2 each 3- or 4-section vehicle signal heads without backplate; 2 each pedestrian heads; and 2 each 9x12 pedestrian pushbutton frames and signage located on the pole below the mastarm plate -- see TE-6.1 for specifics. 4 of 5

16 Standard FYA Signal Head (Max FYA condition 4 section shown) 40" 40" 40" 40" 40" 40" 40" or NOMINALLY HORIZONTAL A U R O R A 5 section option See Note 4 17'-6" 2% SLOPE 2% SLOPE DRAFT\STANDARDS\TRAF-STD\TE-6.5.dwg Notes: 1. Condition shown indicates maximum loading for mastarms from feet in length. Actual length may vary by location 2. Reference current City of Aurora Traffic Signal Structure Specifications for specifics of loading surface areas and weights. 3. City standards requires heads to be centered on lanes with the exception of double left turn lanes, for which the head is centered on the lane line - lane widths and therefore head spacing may vary by location. 4. Although not shown on this detail, the typical installation will also include 2 each 3- or 4-section vehicle signal heads without backplate; 2 each pedestrian heads; and 2 each 9x12 pedestrian pushbutton frames and signage located on the pole below the mastarm plate -- see TE-6.1 for specifics. 5 of 5

17 R Y G R Y G R10-3bR R10-3bL (backmounted: not shown) 10'-0" 8'-0" 6" MIN. R10-3b STANDARD SIGN 0.30" X 3/4" STAINLESS STEEL BANDING STRAPS N:\PWD\DRAFT\STANDARD\TRAF-STD\DWG\2015\TE6-1.dwg, Layout1, 11/21/2014 3:59:52 PM DRAFT\STANDARDS\TRAF-STD\TE-9.1.dwg ADA PUSH BUTTON* 3'-6" 2' MIN. * DRILL AND TAP FOR PUSH BUTTON MOUNTING (BANDING IS NOT ACCEPTABLE) 4'-0" CONDUIT CONTROLLER CABINET DRILL & TAP AS REQ'D. 1 of 2

18 POLE CAP POLE CAP 15' POLE R10-3BL 15' POLE 8' MIN. ADA PUSH BUTTON 3'-6" Base Collar Assembly (TYP) 16"± (TYP) DRAFT\STANDARDS\TRAF-STD\TE-9.4.dwg CORNER 5 SEC 12 CORNER 4 SEC 12 CORNER 3 SEC 12 MEDIAN 2 of 2

19 MAST ARM SIGN MOUNTED USING SIGNFIX SX0220 UNIVERSAL CHANNEL CLAMP WITH SIGNFIX SX0073 MEDIUM CHANNEL EXTRUSION OR APPROVED EQUAL. DRAFT\STANDARDS\TRAF-STD\TE-9.3.dwg

20 COVER A 3/"-STAINLESS 8 STEEL HEX HEAD BOLT W/WASHER B C SPECIFICATIONS/DATA PC and PG Style Assemblies / "-STAINLESS STEEL HEX HEAD BOLT W/WASHER 3 8 BOX D SKID RESISTANT SURFACE E F K J G H COVER (TRAFFIC SIGNAL LOGO-CODE 46) DIMENSIONS (IN.) DESCRIPTION SIZE A B C SMALL (PC) 12 7/8 12 7/8 3/4 HEAVY DUTY (HA) MEDIUM (PG) 23 1/4 13 3/4 2 LOCKING COVER LARGE (PG) 30 1/2 17 1/2 2 WT. LBS BOXES (STACKABLE) DIMENSIONS (IN.) DESCRIPTION OPEN BOTTOM (BA) SIZE SMALL (PC) MEDIUM (PG) LARGE (PG) D 14 3/ /4 E 14 3/4 15 1/2 19 1/4 F G H /4 21 1/4 15 1/2 28 1/2 J 1 1 1/4 1 1/4 K WT. LBS DRAFT\STANDARDS\TRAF-STD\TE-10.2.dwg Specifications Underground enclosures shall be Quazite as manufactured by Hubbell or approved equal. Covers shall be concrete gray color and rated for no less than 15,000 lbs over a 10"x10" area. Enclosures shall be concrete gray in color and rated for no less than 15,000 lbs (SM) or 22,500 lbs (MED/LG). Both covers and enclosures shall be designed and tested to temperatures of -50 F. Covers shall have a minimum coefficient of friction of 0.5. Boxes shall be stackable for extra depth. 1 of 2

21 GENERAL NOTES: SAWCUT FROM LOOP SEE NOTE NO. 2 B TRENCH 1. Pull Box-Special shall be a Water Valve Stem Type pull box made of steel. The pullbox shall have the capability of accepting riser rings for the future overlays. The lid shall have the word "TRAFFIC" printed on it and shall be of the same material as the box. 2. Pull boxes shall have 3/4" to 1" diameter holes drilled or torched 3" from the top to accept a rubber tube. The number of tubes shall be as shown on the plans or as directed by the engineer. 3. Care shall be taken during backfill compaction to prevent collapse of the tubes. A CONDUIT 12"R MIN CONCRETE PATCH AREA A 4. Connect loop lead-ins to home run cable in nearest pull box. (DO NOT splice in water valve box.) PULL BOX-SPECIAL TOP VIEW B ROADWAY 5. Pull box is to be located in a area of the street not heavily traveled: if possible, as centered a minimum of 12" from the gutter pan. 6. A concrete ring (12" minimum radius and 10" minimum depth) shall be installed around the pull box. The rubber tube must extend beyond the concrete to the asphalt joint. 7. Final grade of lid to be 1/4" below asphalt. 8. Wire mesh to stop 3" inside concrete RUBBER TUBE LID WIRE MESH 6x6-W4xW4 OR APPROVED EQUAL ASPHALT 7 1/2"± SAWCUT 10" MIN. 4" CONCRETE 3" 4" 4" CONCRETE 3" 4" CONDUIT SEAL 13' DRAFT\STANDARDS\TRAF-STD\TE-10.3.dwg 24" MIN. 1" MIN. CLEARANCE CONDUIT TO SIDE 18" RADIUS ELBOW 6"± TERMINATE CONDUIT WITHIN 3" OF BOTTOM OTHER CONDUITS IN SAME TRENCH *WIRE MESH TO BE APPROVED BY THE ENGINEER BEFORE INSTALLATION 6"± UNDISTURBED BASE BASE MATERIAL 2 of 2

22 NOTES: 1. DASHED LINES INDICATE LOCATION OF LOOP DETECTORS. 2. SEE TE-0.1, 0.2 AND TE-9.3 FOR LEAD IN CONNECTOR DETAILS. 3. APPROXIMATE LOCATION OF LEAD IN CONNECTOR'S HOME RUN PULL BOX SHALL BE DETERMINED BY TRAFFIC ENGINEER OR DESIGNEE. FL FL 6' FL FL 2' 40' PULL BOX NOTE: CENTER LOOPS IN LANES N:\PWD\DRAFT\STANDARD\TRAF-STD\DWG\2015\TE9-1.dwg, Layout1, 11/20/2014 8:05:44 AM DRAFT\STANDARDS\TRAF-STD\TE-11.1.dwg CL STANDARD APPROACH 1 of 3

23 NOTES: 1. DASHED LINES INDICATE LOCATION OF LOOP DETECTORS. 2. SEE TE-0.1, 0.2 AND TE-9.3 FOR LEAD IN CONNECTOR DETAILS. 3. APPROXIMATE LOCATION OF LEAD IN CONNECTOR'S HOME RUN PULL BOX SHALL BE DETERMINED BY TRAFFIC ENGINEER OR DESIGNEE. 4. MAJOR STREET THROUGH MOVEMENTS SHALL ONLY HAVE LOOP DETECTION AS PER PLAN, AT THE DISCRETION OF THE TRAFFIC ENGINEER. FL 2' 40' 40' 6' 6' 6' NOTE: CENTER LOOPS IN LANES FL DRAFT\STANDARDS\TRAF-STD\TE-11.2.dwg DUAL LEFT TURN LANES DEDICATED RIGHT TURN LANE 2 of 3

24 VARIES 12" VARIES QUADRUPOLE LAYOUT WITH WIRES LAID IN A FIGURE 8 PATTERN SUCH THAT THERE ARE TWICE AS MANY WIRES IN THE CENTER SLOT. 12" OVERLAP CUT TO INSURE SLOT AT CORNER HAS FULL DEPTH. DIRECTION OF WIRE RUN EXITING LOOP A A B B DIRECTION OF WIRE RUN EXITING LOOP 6" CURB OR EDGE OF PAVEMENT TYPICAL SAW CUT DETAIL 1/4" FINISHED GRADE EXPANSION JOINT, PAVEMENT JOINT OR CRACK NONMETALLIC SLOTTED TUBE (TYP.-GARDEN HOSE) MIN. SLOT DEPTH 2" SEALER CONDUCTOR LOOP CABLE (AS REQUIRED) SECTION A-A 12" TO 24" NOTE: WIDEN SLOT AS REQUIRED FOR LENGTH OF TUBE SECTION B-B DRAFT\STANDARDS\TRAF-STD\TE-11.3.dwg SEE TE-10, 3 OF 4, SECTION A-A FOR DETAILS NOTES: LOOP LEAD- IN WIRE 12" LENGTH OF NONMETALLIC FLEXIBLE HOSE SAW CUT SLOT IN PAVEMENT 2" PVC CONDUIT FINISHED GRADE DRAIN TEE (OR WEEP HOLE) AT LOW POINT AS REQUIRED LOOP DETECTOR LEAD-IN INSTALLATION 1. PNEUMATICALLY REMOVE DIRT, DEBRIS AND WATER FROM SAW CUT. 2. WIRE TO BE 14-AWG STRANDED COPPER, XHHW INSULATED BLACK. 3. SEALANT TO BE PRECO/GOLD LABEL FLEX. 4. "HOMERUN" WIRE SHALL BE BELDEN TYPE 8720 OR AN APPROVED SUBSTITUTE. 5. GENTLY TAMP WIRE WITH BLUNT WOOD TOOL TO AVOID DAMAGE TO INSULATION. DO NOT USE SHARP OBJECT. 6. LOOP DETECTOR WIRE LEAD-IN SHALL BE TWISTED (ONE TWIST PER FOOT MIN.) FROM PULLBOX (WHERE SPLICED) TO CABINET. 7. ALL VEHICLE DETECTORS INSTALLED IN CONJUNCTION WITH ROADWAY IMPROVEMENT PROJECTS SHALL BE INSTALLED BEFORE THE FINAL LIFT OF ASPHALT. WATER PROOF SPLICE PULL BOX TO CONTROLLER OR PULL BOX 3 of 3

25 DRAFT\STANDARDS\TRAF-STD\TE-12.1.dwg 1 of 2

26 SCHOOL PROPERTY SCHOOL PROPERTY DRAFT\STANDARDS\TRAF-STD\TE-12.2.dwg 2 of 2

27 SIGN SUPPORT DETAIL 7/16" HOLE 36" 7'-0" IN SIDEWALK AS REQUIRED OR AS SPECIFIED 6" 7/16" HOLE 7/16" HOLE SIGN SIGN INSTALLED W/ UNIVERSAL DRIVE RIVET SIGN POST 2" x 2" x 10' 7/16" DIA. HOLES 1" ON CENTER, PRE- GALVANIZED STEEL. ANCHOR SLEEVE 2 1/4" x 2 1/4" OR AS SPECIFIED. 36" LONG, PRE-GALVANIZED STEEL NOTE: A 10FT POST WILL WORK FOR SIGNS OF 30" OR LESS, ANY SIGNS LARGER WILL REQUIRE A 11FT OR 12FT POST DEPENDING ON SIGN SIZE TO MAINTAIN 7FT OF GROUND CLEARANCE. DRAFT\STANDARDS\TRAF-STD\TE-13.0.dwg SIGN POST INSTALLATION SHALL FOLLOW THE MANUFACTER'S INSTRUCTIONS AND THESE SPECIFICATIONS: NOTE: ALL TUBINGS ARE #12 U.S. GAUGE WALL THICKNESS. 1. DRIVE ANCHOR SLEEVE INTO THE GROUND, LEAVING FOUR HOLES EXPOSED FOR BOLT CONNECTION. FOR HAND INSTALLATION, DRIVE CAP OF PROPER SIZE SHALL BE USED TO PREVENT DAMAGE TO TUBING. SIDEWALK OR MEDIAN SHALL BE POURED AROUND PVC SLEEVE OR EXISTING SIDEWALK OR MEDIAN SHALL BE CORE DRILLED MINIMUM 4" CORE/PVC SLEEVE. 2. INSERT SIGN POST INTO ANCHOR SLEEVE APPROXIMATELY 6" AND BOLT IN PLACE. 3. INSTALLED SIGN AND POST SHALL BE PLUMB AND FREE OF VERTICAL AND LATERAL MOVEMENT.

28 CITY STANDARD STRIPING MATERIALS ON ASPHALT PAVEMENT TYPE TEMPORARY LANE LINES, SYMBOLS AND LEGENDS, AND CROSSWALKS = LESS THAN ONE YEAR = PAINT PERMANENT LANE LINES = THERMOPLASTIC OR EPOXY PERMANENT CROSSWALKS, SYMBOLS, AND LEGENDS = THERMOPLASTIC ON CONCRETE PAVEMENT TYPE LANE LINES SOLID = EPOXY SKIP DASH = INLAID PREFORMED COLD PLASTIC 380I-5 SYMBOLS, LEGENDS, AND CROSSWALKS = INLAID PREFORMED COLD PLASTIC L380IES OR PREFORMED THERMOPLASTIC EXAMPLES OF POSSIBLE LANE CONFIGURATIONS 2.0' 10.0' 4.0' 10.0' 4.0' 10.0' 4.0' FL FL FL 4.5' 3.0' 4.0' 3.0' PARK LANE BIKE LANE PARK LANE BIKE LANE 14.0' 12.0' 13.0' 7.0' 5.0' 12.0' 12.0' 7.0' 5.0' 12.0' 2.0' 10.0' 4.0' 3.5' 10.0' 3.0' 10.0' FL FL FL 2.0' 12.0' 12.0' 12.0' 11.0' 11.0' 10.0' 10.0' 2.0' DRAFT\STANDARDS\TRAF-STD\TE-14.2.dwg 1 of 3

29 5' FLOWLINE NOTES: 1) "ZEBRA" STRIPES REPLACE PARALLEL WALK LINE IN SAME DIMENSION; i.e.,10'-0" OUT TO OUT. 2) "ZEBRA" STRIPES ARE 10'-0"x2'-0" 3) "ZEBRA" STRIPES SHALL BE CENTERED ON THE CURB RAMP(S) ONE "ZEBRA" STRIPE IS CENTERED IN EACH TRAVEL LANE WITH ADDITIONAL "ZEBRA" STRIPE STRADDLING EACH PROJECTED LANE LINE TO LEAVE WHEEL PATHS BETWEEN STRIPES. 5' MIN 7' BIKE LANE CENTER ON BIKE LANE LINE CENTER ON LANE CENTER ON LANE LINE 4" 4" 4" SOLID WHITE LANE LINES DRAFT\STANDARDS\TRAF-STD\TE-14.1.dwg FACE OF CURB 2 of 3

30 CONTINENTAL MARKINGS (EDGE AND TRANSITION ZONES) SPACING OF LINES DETERMINED BY TRAVEL LANE WIDTH (SEE TE-14 SHEET 2 OF 3) 10.0' (TYP) 2.0' (TYP) STANDARD MARKINGS (MIN. REQUIREMENTS FOR ALL CROSSWALKS) 8.0' MIN 1.0' (TYP) DRAFT\STANDARDS\TRAF-STD\TE-14.3.dwg OPTIONAL, PER PLAN OR AS REQUIRED BY THE TRAFFIC ENGINEEER THIS TYPE OF STRIPING FOR CROSSWALK SHALL ONLY BE USED WHEN SPECIAL CROSSWALK PAVEMENTS ARE USED OR AT THE TRAFFIC ENGINEER'S DISCRETION. STRIPING MUST MEET LATEST MUTCD STANDARDS. COLORED AND/OR PATTERNED CONCRETE (INCLUDING PAVERS) MAY BE USED FOR CROSSWALKS IF APPROVED BY THE CITY. A LICENSE AGREEMENT WILL BE REQUIRED FOR MAINTENANCE OF THESE COLORED/PATTERNED CROSSWALKS. COLORS SHALL NOT BE THE SAME AS TRUNCATED DOMES WITHIN THE ADA RAMPS. 3 of 3

31 CASE 1-2 lane undivided local/collector Stop controlled minor street a MINOR ST. b LOCAL/COLLECTOR x R1-1 AREAS TO BE FREE OF OBSTRUCTIONS TO VISIBILITY CASE 2-4 lane undivided collector Stop controlled minor street c MINOR ST. d COLLECTOR x R1-1 AREAS TO BE FREE OF OBSTRUCTIONS TO VISIBILITY DESIGN SPEED 25 mph 30 mph 35 mph 40 mph 45 mph 50 mph a (ft) b (ft) c (ft) d (ft) CORNER SIGHT DISTANCE MEASURED FROM A POINT ON THE CENTERLINE OF THE APPROACH LANE OF THE MINOR ROAD AT THE STOPBAR, STOP SIGN, OR BACK OF CROSSWALK AND MEASURED FROM A HEIGHT OF EYE OF 3.5 FEET ON THE MINOR ROAD TO A HEIGHT OF OBJECT OF 3.5 FEET ON THE MAJOR ROAD. METHOD OF CALCULATION FOR DISTANCE FIGURES BASED ON 2011 AASHTO GUIDELINES. DRAFT\STANDARDS\TRAF-STD\TE-15.1.dwg INTERSECTION SIGHT DISTANCE. INTERSECTIONS SHOULD BE PLANNED AND LOCATED TO PROVIDE AS MUCH SIGHT DISTANCE AS POSSIBLE. IN ACHIEVING A SAFE ROADWAY DESIGN THERE SHOULD BE SUFFICIENT SIGHT DISTANCE FOR THE DRIVER ON THE MINOR ROADWAY TO CROSS OR TURN ONTO THE MAJOR ROADWAY WITHOUT REQUIRING APPROACHING TRAFFIC TO REDUCE SPEED BY MORE THAN 30% OF ITS INITIAL SPEED. MINIMUMS FOR DIFFERENT SPEEDS ARE SHOWN FOR PASSENGER TYPE VEHICLES AT INTERSECTIONS WITH STOP CONTROLS. OTHER TYPES OF VEHICLES, OTHER LANE CONFIGURATIONS, AND OTHER FORMS OF TRAFFIC CONTROL HAVE DIFFERENT INTERSECTION SIGHT DISTANCE REQUIREMENTS. CONSIDERATION SHOULD ALSO BE GIVEN TO MAINTAINING ADEQUATE SIGHT DISTANCE FOR VEHICLES TURNING LEFT FROM THE MAJOR ROADWAY ONTO THE MINOR ROADWAY. PLANTINGS IN THE MEDIAN SHOULD BE ARRANGED SUCH THAT THEY DO NOT RESTRICT VISIBILITY. 1 of 3

32 CASE 3-4 lane divided arterial Stop controlled minor street ARTERIAL e MINOR ST. f x R1-1 AREAS TO BE FREE OF OBSTRUCTIONS TO VISIBILITY CASE 4-6 lane divided arterial Stop controlled minor street ARTERIAL g MINOR ST. h x R1-1 AREAS TO BE FREE OF OBSTRUCTIONS TO VISIBILITY DESIGN SPEED 25 mph 30 mph 35 mph 40 mph 45 mph 50 mph e (ft) f (ft) g (ft) h (ft) CORNER SIGHT DISTANCE MEASURED FROM A POINT ON THE CENTERLINE OF THE APPROACH LANE OF THE MINOR ROAD AT STOPBAR, STOP SIGN, OR BACK OF CROSSWALK AND MEASURED FROM A HEIGHT OF EYE OF 3.5 FEET ON THE MINOR ROAD TO A HEIGHT OF OBJECT OF 3.5 FEET ON THE MAJOR ROAD. METHOD OF CALCULATION FOR DISTANCE FIGURES BASED ON 2011 AASHTO GUIDELINES. DRAFT\STANDARDS\TRAF-STD\TE-15.2.dwg INTERSECTION SIGHT DISTANCE. INTERSECTIONS SHOULD BE PLANNED AND LOCATED TO PROVIDE AS MUCH SIGHT DISTANCE AS POSSIBLE. IN ACHIEVING A SAFE ROADWAY DESIGN THERE SHOULD BE SUFFICIENT SIGHT DISTANCE FOR THE DRIVER ON THE MINOR ROADWAY TO CROSS OR TURN ONTO THE MAJOR ROADWAY WITHOUT REQUIRING APPROACHING TRAFFIC TO REDUCE SPEED BY MORE THAN 30% OF ITS INITIAL SPEED. MINIMUMS FOR DIFFERENT SPEEDS ARE SHOWN FOR PASSENGER TYPE VEHICLES AT INTERSECTIONS WITH STOP CONTROLS. OTHER TYPES OF VEHICLES, OTHER LANE CONFIGURATIONS, AND OTHER FORMS OF TRAFFIC CONTROL HAVE DIFFERENT INTERSECTION SIGHT DISTANCE REQUIREMENTS. CONSIDERATION SHOULD ALSO BE GIVEN TO MAINTAINING ADEQUATE SIGHT DISTANCE FOR VEHICLES TURNING LEFT FROM THE MAJOR ROADWAY ONTO THE MINOR ROADWAY. PLANTINGS IN THE MEDIAN SHOULD BE ARRANGED SUCH THAT THEY DO NOT RESTRICT VISIBILITY. 2 of 3

33 REGULATORY SIGN VISIBILITY ZONE - SEE TABLE FOR REQUIRED DISTANCE MEASURED FROM DRIVER'S EYE POSITION IN CURB LANE TO FACE OF SIGN CLEAR ZONE-MINIMUM 50' R.O.W. LOCATION OF FIRST TREE OR OTHER OBJECT APPROACHING REGULATORY SIGN STOP OR YIELD SIGN DESIGN SPEED REQUIRED DISTANCE 20 mph 25 mph 30 mph 35 mph 40 mph 45 mph 50 mph 115 ft 155 ft 200 ft 250 ft 305 ft 360 ft 425 ft DRAFT\STANDARDS\TRAF-STD\TE-15.3.dwg NOTES 1. A REGULATORY SIGN VISIBILITY ZONE IS REQUIRED ON ALL LOCAL, COLLECTOR, AND/OR ARTERIAL STREETS APPROACHING A STOP OR YIELD REGULATORY SIGN. 2. IN ADDITION TO THE REQUIREMENTS OF TE-13.1 and 13.2, AND THE REQUIREMENTS OF THE REGULATORY SIGN VISIBILITY ZONE AS SHOWN ABOVE, A CLEAR ZONE OF A MINIMUM OF 50' IS REQUIRED AS SHOWN ABOVE. 3. TREES OR OTHER OBJECTS NORMALLY PLACED IN THE REGULATORY SIGN VISIBILITY ZONE OR CLEAR ZONE SHALL BE INSTALLED AT A NEW LOCATION TO BE DETERMINED BY THE PLANNING DEPARTMENT, LANDSCAPE ARCHITECT, of 3

DESIGN CRITERIA DIVISION 4900 TRAFFIC SIGNALS

DESIGN CRITERIA DIVISION 4900 TRAFFIC SIGNALS DESIGN CRITERIA DIVISION 4900 TRAFFIC SIGNALS 4901 GENERAL: These criteria shall be adhered to for the design of all publiclyfinanced or privately-financed traffic signal systems to be installed in the

More information

APPENDIX G SIGNAGE AND STRIPING SUPPLEMENT

APPENDIX G SIGNAGE AND STRIPING SUPPLEMENT APPENDIX G SIGNAGE AND STRIPING SUPPLEMENT DOUGLAS COUNTY SIGNAGE AND STRIPING SUPPLEMENT TO DOUGLAS COUNTY ROADWAY DESIGN & CONSTRUCTION STANDARDS UPDATED MAY 2018 TABLE OF CONTENTS 1.00: GENERAL REQUIREMENTS...

More information

CHAPTER 8 STAKING SIGNALS AND LIGHTING FIELD GUIDE. 8.1 Staking Traffic Control Signal Systems

CHAPTER 8 STAKING SIGNALS AND LIGHTING FIELD GUIDE. 8.1 Staking Traffic Control Signal Systems CHAPTER 8 STAKING STAKING Correct staking of traffic control signal or lighting systems is critical to the appropriate placement of system components. 8.1 Traffic Control Signal Systems Locating the components

More information

STAKING TRAFFIC CONTROL SIGNAL SYSTEMS

STAKING TRAFFIC CONTROL SIGNAL SYSTEMS Locating the components of a traffic control signal is not an exact science; many factors influence the location of the components. These factors include: lane widths, radii, pedestrian curb ramp requirements,

More information

2010 STANDARD SPECIFICATIONS STANDARD DRAWINGS

2010 STANDARD SPECIFICATIONS STANDARD DRAWINGS CITY OF REDMOND, OREGON 2010 STANDARD SPECIFICATIONS STANDARD DRAWINGS TABLE OF CONTENTS SECTION 1 TRENCHES TITLE 1-1 Utility Trench 1-2 Water Line & Sewer Line Separation 1-3 RR X-ING Single/Joint Use

More information

Page 1 of 1 04/19/13 SBR

Page 1 of 1 04/19/13 SBR Office of Roadway Engineering - Plan Insert Sheets Number Title Date Number Title Date Number Title Date 201015 Extension of Anchor Bolts 07/20/12 207000 Bikeway Pavement Marking Details 01/18/13 202010

More information

ADA Operations Contact Info

ADA Operations Contact Info Intro ADA Operations Contact Info Todd Grugel ph: 651-366-3531 email: todd.grugel@state.mn.us Joe Zilka ph: 651-366-3311 email: joseph.zilka@state.mn.us Harvey Unruh ph: 651-216-2912 email: harvey.unruh@state.mn.us

More information

BARRIER OFFSET 0" A 6" 6" A 12" 12" A 26" A 26" 3A OR 4A L OR S * ** L OR S L OR S

BARRIER OFFSET 0 A 6 6 A 12 12 A 26 A 26 3A OR 4A L OR S * ** L OR S L OR S ACCEPTABLE (TCB) TYPES AND ANCHORING DETAILS BASED ON UNDERLYING SURFACE TYPE AND BARRIER OFFSET FROM DROP-OFF BARRIER OFFSET UNDERLYING SURFACE 0" A 6" 6" A 12" 12" A 26" A 26" TCB TYPE DETAIL TCB TYPE

More information

ROADWAY AND PARKING DETAILS TYPICAL STREET SECTIONS PRINCIPAL ARTERIAL NOT TO SCALE

ROADWAY AND PARKING DETAILS TYPICAL STREET SECTIONS PRINCIPAL ARTERIAL NOT TO SCALE NOTES: O:\Division Information\Engineering\Documents\Engineering and Construction\COMMERCE CITY\CAD files\2016 Updated Files\307-01 thru 307-09 (Roadway & Parking Typical Sections).dwg 6' SIDEWALK MAY

More information

Turning templates shall be shown on the signal plan for review during preliminary plan submittals.

Turning templates shall be shown on the signal plan for review during preliminary plan submittals. J. TRAFFIC SIGNALS The traffic signal system shall consist of the signal controller, signal poles, signal heads, cable, conduit, ehicle detectors and any other appurtenances required to proide a complete,

More information

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN Important: Read all instructions and refer to local codes prior to installation. l Local soil conditions may require more gravel for drainage. l

More information

Updated There is no park access points beyond the limit of the phase I work. roadway to be constructed Viewport has been along full limits of the park

Updated There is no park access points beyond the limit of the phase I work. roadway to be constructed Viewport has been along full limits of the park The signs will be installed as Temporary signs the color (Orange/White) have been added to the plans. Need to specify color to be used for stripes. Closures that may be in place for extended periods need

More information

PUBLIC WORKS DEPARTMENT SIGN AND MARKING PROCEDURES AND GUIDELINES

PUBLIC WORKS DEPARTMENT SIGN AND MARKING PROCEDURES AND GUIDELINES PUBLIC WORKS DEPARTMENT SIGN AND MARKING PROCEDURES AND GUIDELINES 2015 FORWARD The Revised Code of Washington (RCW) 47.36, Traffic Control Devices, requires the Washington State Department of Transportation

More information

0 CITY OF SANTA ANA 0

0 CITY OF SANTA ANA 0 : A traffic control plan (Plan) is required whenever work is to be performed within the public right-of-way and is deemed necessary by the City of Santa Ana's (City) Traffic Engineer. Work cannot start

More information

ADA Training Accessible Pedestrian Signal (APS) 2018 MnDOT

ADA Training Accessible Pedestrian Signal (APS) 2018 MnDOT ADA Training Accessible Pedestrian Signal (APS) 2018 MnDOT APS and ADA APS is not currently an ADA Standard and is provided at the discretion of the Title II entity APS is recognized in the MnMUTCD, but

More information

SCOPE Application, Design, Operations,

SCOPE Application, Design, Operations, SCOPE Application, Design, Operations, Maintenance, etc.: Typical Traffic Control Signals Pedestrian Hybrid Beacons Emergency Vehicle One-Lane/Two-Way Facilities, Freeway Entrance Ramps, and Movable Bridges

More information

Driveway Design Criteria

Driveway Design Criteria Design Manual Chapter 5 - Roadway Design 5L - Access Management 5L-4 Driveway Design Criteria A. General For efficient and safe operations, access drives and minor public street intersections can be improved

More information

Chapter 4 TOOLBOX AND SAMPLE BIKE BOULEVARD LAYOUT

Chapter 4 TOOLBOX AND SAMPLE BIKE BOULEVARD LAYOUT Chapter 4 TOOLBOX AND SAMPLE BIKE BOULEVARD LAYOUT OVERVIEW This chapter describes a cohesive set of strategies to create a bicycle boulevard, namely to make streets safer and more efficient for bicycle

More information

SECTION 48 - TRAFFIC STRIPES AND PAVEMENT MARKINGS TABLE OF CONTENTS

SECTION 48 - TRAFFIC STRIPES AND PAVEMENT MARKINGS TABLE OF CONTENTS SECTION 48 - TRAFFIC STRIPES AND PAVEMENT MARKINGS TABLE OF CONTENTS Section Page 48-1 GENERAL... 48.1 48-2 THERMOPLASTIC TRAFFIC STRIPES AND PAVEMENT MARKINGS... 48.1 48-3 PAINTED TRAFFIC STRIPES AND

More information

Field guide for Accessible Public Rights-of-Way Edition

Field guide for Accessible Public Rights-of-Way Edition Field guide for Accessible Public Rights-of-Way 2017 Edition CONTENTS PEDESTRIAN FACILITIES IN THE PUBLIC RIGHT-OF-WAY Pedestrian access routes 3 Components 3 Continuous width 3 Median and pedestrian refuge

More information

SECTION 48 - TRAFFIC STRIPES AND PAVEMENT MARKINGS TABLE OF CONTENTS

SECTION 48 - TRAFFIC STRIPES AND PAVEMENT MARKINGS TABLE OF CONTENTS SECTION 48 - TRAFFIC STRIPES AND PAVEMENT MARKINGS TABLE OF CONTENTS Section Page 48-1 GENERAL...48.1 48-2 THERMOPLASTIC TRAFFIC STRIPES AND PAVEMENT MARKINGS...48.1 48-3 PAINTED TRAFFIC STRIPES AND PAVEMENT

More information

ADA PRESENTATION (CURB RAMPS)

ADA PRESENTATION (CURB RAMPS) ADA PRESENTATION (CURB RAMPS) ACECNJ/NJDOT/FHWA DESIGN SUMMIT Warren Howard New Jersey Department of Transportation May 21, 2013 ADA Curb Ramps NJDOT wants curb ramps to be designed & constructed properly

More information

Updated There is no park access roadway to be constructed points beyond the limit of along full limits of the park's the phase I work. Phase 1. Revise

Updated There is no park access roadway to be constructed points beyond the limit of along full limits of the park's the phase I work. Phase 1. Revise The signs will be installed as Temporary signs the color (Orange/White) have been added to the plans. Need to specify color to be used for stripes. Closures that may be in place for extended periods need

More information

CITY OF RICHMOND, VIRGINIA

CITY OF RICHMOND, VIRGINIA CITY OF RICHMOND, VIRGINIA DEPARTMENT OF PUBLIC WORKS TRANSPORTATION ENGINEERING DIVISION Bikeway / Trail - Installation Bike Lanes Throughout the City Between Dock Street and Main Street U000-27-R44,

More information

Revisions to Larimer County Urban Area Street Standards (2016 Update)

Revisions to Larimer County Urban Area Street Standards (2016 Update) 1.9.2 B 1-18 Street Construction Policy 1.14 (new) 1-29 Complete Streets in Fort Collins 4.1.1 04-01 General 4.1.3 04-01 Capacity and Safety Issues 4.1.3 B 04-02 Pedestrian Traffic Considerations 4.1.4

More information

ADA Training Standard Plans

ADA Training Standard Plans ADA Training Standard Plans SCREEN READABLE VERSION IS IN THE MAKING AND WILL BE MADE AVAILABLE SOON 2018 MnDOT 2 Standard Plans 2017 Overview Overview PROWAG and Curb Ramp Basics Curb Ramp Types ADA Curb

More information

City of Margate, Florida. Neighborhood Traffic Management Manual

City of Margate, Florida. Neighborhood Traffic Management Manual City of Margate, Florida Neighborhood Traffic Management Manual Table of Contents Page No. I. INTRODUCTION... 1 II. TRAFFIC CALMING REQUEST AND PROCESSING PROCEDURES... 2 1. COMPLETE AND SUBMIT PROJECT

More information

6.0 ENGINEERING. Build Anything Better. REPRINTED 2017

6.0 ENGINEERING. Build Anything Better.  REPRINTED 2017 6.0 ENGINEERING TABLE OF CONTENTS 6.1 U.S. ENGINEERING ANALYSIS REPORT... P. 6-3 BELOW-GRADE WALL REINFORCEMENT TABLES... P. 6-5 ABOVE-GRADE WALL REINFORCEMENT TABLES.. P. 6-21 LINTEL REINFORCEMENT TABLES...P.

More information

CITY OF ROSEVILLE DESIGN AND CONSTRUCTION DETAILS

CITY OF ROSEVILLE DESIGN AND CONSTRUCTION DETAILS CITY OF ROSEVILLE DESIGN AND CONSTRUCTION DETAILS Trench Backfill Utility Trench Paving Backfill and Embedment TB 1 HDPE, SRHDPE & PVC Storm Drain Pipe Only (Nonrigid) Bedding and Backfill TB2 Deep Cut

More information

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS DESIGNED TO HOLD THE WEIGHT FOR ELECTRICAL CABLE AS IT HANGS IN VERTICAL, SLOPING OR HORIZONTAL POSITIONS. EASILY INSTALLED AND REMOVED USING NO

More information

County of Sacramento Standard Construction Specifications January 1, 2008 TECHNICAL PROVISIONS

County of Sacramento Standard Construction Specifications January 1, 2008 TECHNICAL PROVISIONS County of Sacramento Standard Construction Specifications January 1, 2008 TECHNICAL PROVISIONS SECTION 48 TRAFFIC STRIPES AND PAVEMENT MARKINGS 48-1 GENERAL Traffic stripes and pavement markings shall

More information

STATIONARY TRUCK INTERNAL HALYARD V-CLEAT FLAGPOLES FOR QUICK AND PROFESSIONAL INSTALLATION READ ALL INSTRUCTIONS BEFORE PROCEEDING

STATIONARY TRUCK INTERNAL HALYARD V-CLEAT FLAGPOLES FOR QUICK AND PROFESSIONAL INSTALLATION READ ALL INSTRUCTIONS BEFORE PROCEEDING 9390 South 300 West, Sandy, Utah 84070 801-562-0123 800-782-0500 ColonialFlag.com STATIONARY TRUCK INTERNAL HALYARD V-CLEAT FLAGPOLES FOR QUICK AND PROFESSIONAL INSTALLATION READ ALL INSTRUCTIONS BEFORE

More information

Figure 3B-1. Examples of Two-Lane, Two-Way Marking Applications

Figure 3B-1. Examples of Two-Lane, Two-Way Marking Applications Figure 3B-1. Examples of Two-Lane, Two-Way Marking Applications A - Typical two-lane, two-way marking with passing permitted in both directions B - Typical two-lane, two-way marking with no-passing zones

More information

SECTION 3 STREET DESIGN

SECTION 3 STREET DESIGN 3.01 GENERAL SECTION 3 STREET DESIGN For purposes of geometric and structural design, streets shall be classified according to the following table. The City Engineer will determine the class of all proposed

More information

Utility Anchor System

Utility Anchor System Utility Anchor System The Dayton Superior Utility Anchor System is designed to economically simplify the lifting and handling of precast concrete elements. Its economics, ease of use and versatility will

More information

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM I N S TA L L AT I O N / I MN SA TA I N TL EL NAT AIN OC N E / MI AN IS NT RE UN CA TN I CO E N SI N S T R U C T I O N S INSTALLATION INSTRUCTIONS FOR -FRU OPTION Important: Read all instructions and refer

More information

8MAY15 US RACK, Inc Falcon Drive, Madera, CA

8MAY15 US RACK, Inc Falcon Drive, Madera, CA 8MAY15 US RACK, Inc. - 2850 Falcon Drive, Madera, CA 93637-559-661-3050 INSTRUCTIONS for Bedrail-mounted MOTORCYCLE RACK, Model 2001-4TRA WARNING: Do NOT attempt to install or use this rack without following

More information

City of Roseville Section 13 Design Standards. _Bikeways January 2016 SECTION 13 BIKEWAYS

City of Roseville Section 13 Design Standards. _Bikeways January 2016 SECTION 13 BIKEWAYS SECTION 13 BIKEWAYS 13-1 GENERAL The City of Roseville bikeway standards are designed to insure that transportation and recreational bikeways are constructed in a manner that would provide a safe and comfortable

More information

TYPICAL CONTRACTION JOINT PLAN TYPICAL EXPANSION JOINT PLAN T LOCATION AND DETAIL OF JOINTS FOR SIDEWALK

TYPICAL CONTRACTION JOINT PLAN TYPICAL EXPANSION JOINT PLAN T LOCATION AND DETAIL OF JOINTS FOR SIDEWALK CURB EXPANSION JOINTS (TYP) BOULEVARD 5 t /4 TOOLED EDGES EXPANSION JOINTS (TYP) CONTRACTION JOINTS (TYP) 2 m (TYP) BOULEVARD CURB EXPANSION JOINTS (TYP) EVERY 6 m PLAN TYPICAL CONTRACTION JOINT CURB 12

More information

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD EDFP217C EDFP217RAC Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING

More information

KlassikDrain Section. Technical Handbook and Product Catalog. General purpose trench drainage

KlassikDrain Section. Technical Handbook and Product Catalog. General purpose trench drainage Technical Handbook and Product Catalog Surface Drainage 6 Surface drainage options 8 Product selection 10 Trench drain hydraulics 16 Loadings 22 Material data 24 End user requirements Standard Products

More information

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS CONTENTS: 1.0 General Information 2.0 Preparation and Splicing of PinPoint Wire 3.0 PinPoint Direct Bury Splice Kit Specifications

More information

PROCEDURE FOR ACCOMMODATING PEDESTRIANS IN WORK ZONES FOR CONSTRUCTION AND MAINTENANCE

PROCEDURE FOR ACCOMMODATING PEDESTRIANS IN WORK ZONES FOR CONSTRUCTION AND MAINTENANCE PROCEDURE FOR ACCOMMODATING PEDESTRIANS IN WORK ZONES FOR CONSTRUCTION AND MAINTENANCE A.1 STANDARD Measures shall be taken to accommodate pedestrian traffic through and/or around Work Zones for Construction

More information

Developed by: The American Traffic Safety Services Association (ATSSA) 15 Riverside Parkway, Suite 100 Fredericksburg, VA

Developed by: The American Traffic Safety Services Association (ATSSA) 15 Riverside Parkway, Suite 100 Fredericksburg, VA Addendum Developed by: The American Traffic Safety Services Association (ATSSA) 15 Riverside Parkway, Suite 100 Fredericksburg, VA 22406-1022 800-272-8772 This material is based upon work supported by

More information

Access requests to County streets and roadways are processed through one of the following methods:

Access requests to County streets and roadways are processed through one of the following methods: 13.1 GENERAL APPLICATION PROCESS Access requests to County streets and roadways are processed through one of the following methods: A. Planned Developments may set general locations for access points.

More information

Consult with manufacturers concerning permeation of the pipe walls, jointing materials, valve seats, etc.

Consult with manufacturers concerning permeation of the pipe walls, jointing materials, valve seats, etc. Design Manual Chapter 4 - Water Mains 4C - Facility Design 4C-1 Facility Design A. General Water mains and appurtenances, including hydrants and valves, should be provided along all streets including connections

More information

Field guide for Accessible Public Rights-of-Way Edition

Field guide for Accessible Public Rights-of-Way Edition Field guide for Accessible Public Rights-of-Way 2015 Edition BRIEFING MEMO SUBJECT: Department of Justice/Department of Transportation Joint Technical Assistance on Title II of the Americans with Disabilities

More information

Broad Street Bicycle Boulevard Design Guidelines

Broad Street Bicycle Boulevard Design Guidelines Broad Street Bicycle Boulevard Design Guidelines Building from the strategies introduced in the 2013 Bicycle Transportation Plan and community input received thus far, City Transportation Staff have identified

More information

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual 27.75 23.75 25.50 20.75 Specifications: 8-13 GPM 100 strand fiber - Bubbler 75 strand fiber - Spillway Light Bar 45 ft. fiber tail

More information

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual

LoneStar Fiberglass Pools. Do-It-Yourself. Installation Manual LoneStar Fiberglass Pools Do-It-Yourself Installation Manual Chris 1/3/2008 Do-It-Yourself The installation of a LoneStar Fiberglass pool is a much simpler task than most people think. What is important

More information

SCOUT DECK ANCHOR 3 1/4" BONDING SCREW

SCOUT DECK ANCHOR 3 1/4 BONDING SCREW SCOUT DECK ANCHOR 16" 16" 1" X 4" ANCHOR BOLT (4) 10" 3 1/8" 5" 6" MIN COPPER WIRE TO ATTACH TO BONDING GRID 3 1/4" BONDING SCREW CONCRETE DECK SPECIFICATIONS: THE AQUA CREEK PRODUCTS' SCOUT DECK ANCHOR

More information

Bases, Ballasts, and Paving

Bases, Ballasts, and Paving Sections Included In This Standard: 1.1 Paving and Surfacing 1.2 Protection of the Work 1.3 Repair of Pavement 1.4 Pavement Marking 1.1 PAVING AND SURFACING A. DESIGN REQUIREMENTS 1. Applicable Design

More information

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and Bulletin 68-7-11 Swimming pool, hot tub and spa installations Rules 68-000, 68-056, 68-058, 68-064, 68-068, 68-302 and 68-404 Scope (1) Swimming pools - general (2) Grounding & bonding (a) Bonding for

More information

S Surge Arresters

S Surge Arresters Surge Arresters UltraSIL Polymer-Housed VariSTAR Type US, UH, and UX Station-Class Surge Arresters Installation and Maintenance Instructions Service Information S235-88-1 Contents Product Information...........................1

More information

INDEX. Geometric Design Guide for Canadian Roads INDEX

INDEX. Geometric Design Guide for Canadian Roads INDEX Acceleration lane, see Lanes, Acceleration Access, 8.1 Access Management and Functional Classification 8.2 Access Management by Design Classification 8.3 Access Configuration 8.4 Building Set-Back Guidelines

More information

BALL STOP INSTALLTION GUIDE

BALL STOP INSTALLTION GUIDE BALL STOP INSTALLTION GUIDE GROUND SLEEVE INSTALLATION: 1. Locate the exact location of the ground sleeve. NOTE: Maximum recommended pole spacing is 20 feet on center. 2. Excavate the pole footing; refer

More information

Standards vs. Guidelines. Public Right-of Way Accessibility Guidelines (PROWAG)

Standards vs. Guidelines. Public Right-of Way Accessibility Guidelines (PROWAG) www.access-board.gov Public Right-of Way Accessibility Guidelines (PROWAG) Juliet Shoultz, P.E Transportation Systems Engineer US Access Board Standards vs. Guidelines Guidelines are developed by the Access

More information

UPDATE ARLINGTON COUNTY. Bicycle Parking Standards

UPDATE ARLINGTON COUNTY. Bicycle Parking Standards 2018 UPDATE ARLINGTON COUNTY Bicycle Parking Standards INTRODUCTION This guide is designed to give developers, architects, property managers, construction professionals, and County staff, the knowledge

More information

Preparing a Curb Ramp Project. December 15, 2010

Preparing a Curb Ramp Project. December 15, 2010 Preparing a Curb Ramp Project December 15, 2010 3 Tiers of Project Types Non-Signalized Curb Ramp Reconstruction - Typically utilizing standard plans and identifying ramp types at each quadrant Signalized

More information

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text. SECTION 10185 SHOWER AND BATH ENCLOSURES Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Bathtub wall enclosures. B. Shower wall

More information

I.H.S INSTALLATION INSTRUCTIONS

I.H.S INSTALLATION INSTRUCTIONS I.H.S INSTALLATION INSTRUCTIONS TOOLS REQUIRED The following tools will be required for installation of your I.H.S. system. Item Qty Needed 9/16 Open End Wrench 2 3/4 Open End Wrench 1 1/2 Open End Wrench

More information

Soma Wind Generators

Soma Wind Generators Soma Wind Generators 13M WINH TOWER INSTALLATION MANUAL ERTIFIED to AS4100 Steel Structures ode AS3995 (1994) Design of Steel Lattice Towers and Masts AS1170.2 (1989) SAA Wind Loading Manufactured by SOMA

More information

W A S T E W A T E R T R E A T M E N T S Y S T E M S

W A S T E W A T E R T R E A T M E N T S Y S T E M S W A S T E W A T E R T R E A T M E N T S Y S T E M S PROCEDURES FOR ASSEMBLY AND INSTALLATION A Division of Consolidated Trmt Systems, Inc. 1501 Commerce Center Drive Franklin, OH 45005 Tel: 937-746-2727

More information

MEMORANDUM Ashford Dunwoody Road: Request to waive right of way dedication requirements of Sec

MEMORANDUM Ashford Dunwoody Road: Request to waive right of way dedication requirements of Sec MEMORANDUM To: From: Mayor and City Council Michael Smith, Public Works Director Date: October 13, 2014 Subject 4400 Ashford Dunwoody Road: Request to waive right of way dedication requirements of Sec.

More information

TOWN of CHEEKTOWAGA Permit Application for Swimming Pools, Hot Tubs, or Personal Spas

TOWN of CHEEKTOWAGA Permit Application for Swimming Pools, Hot Tubs, or Personal Spas Permit Application for Swimming Pools, Hot Tubs, or Personal Spas / 20 - Date of Application Received By Permit No. APPLICANT to COMPLETE the PINK PORTION! ( ) ( ). Applicant s Name Daytime Phone No. Cell

More information

PUSH PIER SYSTEMS STABILITY. SECURITY. INTEGRITY. Push Pier Systems PN #MBPPT

PUSH PIER SYSTEMS STABILITY. SECURITY. INTEGRITY. Push Pier Systems PN #MBPPT PUSH PIER SYSTEMS STABILITY. SECURITY. INTEGRITY. PN #MBPPT Push Pier Systems About Foundation Supportworks is a network of the most experienced and knowledgeable foundation repair and new construction

More information

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B ASSEMBLY INSTRUCTIONS step-by-step assembly and installation Version 1, Rev A PCN 080311-2 SP3363-1 Side-of-Pole Mount for 1 Module (SPM1)

More information

TRAFFIC CONTROL DEVICES

TRAFFIC CONTROL DEVICES TRAFFIC CONTROL DEVICES SIGNS Temporary traffic control work zone signs include regulatory, warning and guide signs utilized to provide regulations, warnings and guidance information to road users impacted

More information

THOR 10 HAMMER CAGE INSTRUCTIONS

THOR 10 HAMMER CAGE INSTRUCTIONS 75 " 7m 78 4" m 6" 8.8m 45 ".70m 4.9deg 6 4" 6m 44 4".67m 75 " 7m 9 4" 0m 44".m 497 4".64m The 70, Thor Hammer Cage, consists of four heavy duty aluminum net poles. The unique pole structure reduces the

More information

TOWER INSPECTION REPORT

TOWER INSPECTION REPORT 3010 S. Hwy 77, Suite 600 Waxahachie, Texas 75165 http://ctctower.com Office: 972/923-9504 Fax: 972/923-9619 TOWER INSPECTION REPORT PREPARED FOR MR. CUSTOMER 1,563 GUYED TOWER NEAR CITY, STATE JANUARY

More information

NHR Powder Feed Hopper

NHR Powder Feed Hopper Instruction Sheet P/N 0804A0 NHR-8-50 Powder Feed Hopper Description This instruction sheet provides specifications, installation and operation instructions, and parts lists for the NHR-8-50 powder feed

More information

ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL

ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL AFTER MARCH 1, 2012 ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL 400.1 Description. This item shall govern for all excavation required for the construction of all structures, except pipe or box sewers for

More information

ADA on Construction. Guidance for Section C Plan Preparers

ADA on Construction. Guidance for Section C Plan Preparers ADA on Construction Guidance for Section C Plan Preparers Some impacts cannot be avoided and those impacts apply to residents, businesses, motorists, and pedestrians alike. However, good planning can minimize

More information

NHR-X-X Encore Feed Hoppers

NHR-X-X Encore Feed Hoppers Instruction Sheet P/N 60986-0 NHR-X-X Encore Feed Hoppers WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation.

More information

DETECTABLE WARNING SURFACES SHALL BE PROVIDED AT THE FOLLOWING LOCATIONS ON PEDESTRIAN ACCESS ROUTES:

DETECTABLE WARNING SURFACES SHALL BE PROVIDED AT THE FOLLOWING LOCATIONS ON PEDESTRIAN ACCESS ROUTES: GENERAL NOTES: CURB NOTES: 5'-0" MIN 5'-0" 5'-0" MIN 1. 2. THESE SHEETS ARE IN ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT (ADA), AND THE REQUIREMENTS OF THE 2011 PROPOSED ACCESSIBILITY GUIDELINES

More information

Hospital Link Project Project Update September 2017

Hospital Link Project Project Update September 2017 Hospital Link Project Project Update September 2017 General The project provides a link from Riverside Drive and the Transitway to the Hospital Link Road. Construction is well underway. Read on for important

More information

Accommodating Pedestrians in the Work Zone

Accommodating Pedestrians in the Work Zone Accommodating Pedestrians in the Work Zone Guidance for Section C Plan Preparers Some impacts cannot be avoided and those impacts apply to residents, businesses, motorists, and pedestrians alike. However,

More information

American Flagpole & Flag Co. 1(800)

American Flagpole & Flag Co.   1(800) SENTRY CONCEALED HALYARD-REVOLVING TRUCK GROUND SET INSTALLATIONS INSTRUCTIONS 1. Dig foundation as detailed in SECTION A FOUNDATION SPECIFICATIONS, set sleeve in enter of hole with top 2 above grade.

More information

2014 FHWA Aging Road User Handbook. Recommendations to Accommodate Aging Pedestrians. Lifesaver National Conference. What is the Handbook?

2014 FHWA Aging Road User Handbook. Recommendations to Accommodate Aging Pedestrians. Lifesaver National Conference. What is the Handbook? 2014 FHWA Aging Road User Handbook Recommendations to Accommodate Aging Pedestrians Lifesaver National Conference March 17, 2015 Revised June 2014 1 What is the Handbook? 1998 1st Edition 2001 2nd Edition

More information

PLACEMENT OF SIGNS RECOMMENDED PRACTICES SUB-SECTION

PLACEMENT OF SIGNS RECOMMENDED PRACTICES SUB-SECTION Page 1 of 6 RECOMMENDED PRACTICES PART SECTION SUB-SECTION HIGHWAY SIGNS GENERAL General Proper positioning of signs is an important element in the overall control of traffic within a roadway network.

More information

TRANSMITTAL LETTER. Revision to Publication 149, Chapter 20 (Criteria for the Design of Traffic Signal Supports) - March 2009 Edition

TRANSMITTAL LETTER. Revision to Publication 149, Chapter 20 (Criteria for the Design of Traffic Signal Supports) - March 2009 Edition OS-299 (7-08) TRANSMITTAL LETTER PUBLICATION: Publication 149 - Traffic Signal Design Handbook DATE: 10/14/10 SUBJECT: Revision to Publication 149, Chapter 20 (Criteria for the Design of Traffic Signal

More information

Installation and Training Manual

Installation and Training Manual AirForce1 Tower Kit Installation and Training Manual FuturEnergy Limited Ettington Park Business Centre Stratford upon Avon CV37 8BT +44 (0)1789 451070 Table of Contents Safety Notes... 3 Parts Supplied

More information

Paul Vraney Bureau of Project Development 02/11/2016

Paul Vraney Bureau of Project Development 02/11/2016 Paul Vraney Bureau of Project Development 02/11/2016 ADA background & alterations definition Design considerations Provide sufficient layout data Curb ramp selection Maximum curb ramp and gutter slopes

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

R A M P U P! - City of Tacoma's Curb Ramp Installation Matrix

R A M P U P! - City of Tacoma's Curb Ramp Installation Matrix R A M P U P! - City of Tacoma's Curb Ramp Installation Matrix DESCRIPTION OF WORK NEW CONSTR. ALTERATION MAINT. COMMENTS STREET PAVING New street paving or overlay through an intersection (Figures 1 &

More information

Appendix F: Wayfinding Protocol and Best Practices

Appendix F: Wayfinding Protocol and Best Practices Appendix F: Wayfinding Protocol and Best Practices Table of Contents Introduction... 259 Current Practice... 259 Policy and Regulatory Framework... 260 Best Practices... 262 Chicago, IL... 262 Seattle,

More information

Check with local zoning official for property line distance requirements.

Check with local zoning official for property line distance requirements. RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family

More information

FITNESS, SAFETY & MEDICAL SUPPLIES

FITNESS, SAFETY & MEDICAL SUPPLIES COMMERCIAL SERIES LIFTS TABLE OF CONTENTS 1. TRI-Point Anchor System 2. TRI-Point Paver Instruction Anchor Method 3. TRI-Point Retro-Fit Anchor System 4. TRI-Point Drop In Anchor System 5. Commercial Series

More information

NEW FEDERAL RULES BREAKAWAY SIGN SUPPORTS ARE REQUIRED

NEW FEDERAL RULES BREAKAWAY SIGN SUPPORTS ARE REQUIRED NEW FEDERAL RULES BREAKAWAY SIGN SUPPORTS ARE REQUIRED The Manual on Uniform Traffic Control Devices (MUTCD), which is the national standard used for all roads open to public travel, states that roadside

More information

LEGACY II TM STARTING PLATFORMS

LEGACY II TM STARTING PLATFORMS LEGACY II TM STARTING PLATFORMS INSTALLATION INSTRUCTIONS CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P.O. Box 400 1017 SW Berg Parkway Canby, Oregon 97013 (503) 266-2231 Fax (503) 266-4334

More information

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump

More information

TOWER INSTALLATION MANUAL For A.R.E. Guyed Pipe Towers Short Towers 43, 64 and 85 feet tall

TOWER INSTALLATION MANUAL For A.R.E. Guyed Pipe Towers Short Towers 43, 64 and 85 feet tall TOWER INSTALLATION MANUAL For A.R.E. Guyed Pipe Towers Short Towers 43, 64 and 85 feet tall Contents 1) Introduction...2 2) Site Selection and Preparation...2 3) Tools List...3 4) Parts List...4 5) Tower

More information

6. TITLE: Amendments to the Larimer County Land Use Code and the Larimer County Road Manual

6. TITLE: Amendments to the Larimer County Land Use Code and the Larimer County Road Manual 6. TITLE: Amendments to the Larimer County Land Use Code and the Larimer County Road Manual REQUEST: APPLICANT: To make a number of changes to the adopted Larimer County Land Use Code and Road Manual.

More information

3/4 SafeClaw Anchorage Connectors

3/4 SafeClaw Anchorage Connectors Operations and Instruction Manual Model #4075 Portable Concrete Anchorage Connector ANSI Z359.1-07 5,000 lbs / 22kn OHSA 1910.66 & 1926.502 Effective: 01/2012 Expires: 01/2022 IM-0049 REVA 3/4 SafeClaw

More information

POP UP ANCHOR. Part Number Spectrum Lane ~ Missoula MT ~

POP UP ANCHOR. Part Number Spectrum Lane ~ Missoula MT ~ POP UP ANCHOR Part Number 153169 7100 Spectrum Lane ~ Missoula MT 59808 800.791.8056 ~ www.spectrumproducts.com You have purchased a Spectrum Products Pop Up Lane Rope Anchor. Providing the unit is installed

More information

Aquor House Hydrant V2

Aquor House Hydrant V2 Aquor House Hydrant V2 IN-WALL OUTDOOR FAUCET SYSTEM FLUSH-MOUNT QUICK-CONNECT SELF-DRAINING ANTI-SIPHON NON-FREEZE VBH-SERIES AQUOR HOUSE HYDRANT V2: WALL HYDRANT / FREEZELESS SILLCOCK Freezeless sillcock

More information

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED

More information

SECTION DOMESTIC WATER PIPING

SECTION DOMESTIC WATER PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. B. Related Sections

More information

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual STOP! Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY

More information

Tract or Parcel Project Name PCN Checked By Date

Tract or Parcel Project Name PCN Checked By Date Tract or Parcel Project Name PCN Checked By Date City of Escondido Public Works Department Signing & Striping Plan Review Checklist The following checklist is a guideline for new CIP and development construction

More information