M8, M12, M18, M30 Cube 40 x 40 mm. 2 mm 15 mm 2 mm 15 mm 20 mm 40 mm

Size: px
Start display at page:

Download "M8, M12, M18, M30 Cube 40 x 40 mm. 2 mm 15 mm 2 mm 15 mm 20 mm 40 mm"

Transcription

1 Bulletin 872C, 871TM, 871FM, 871C, 871P Product Line Overview Proximity Sensors (872C, 871TM, 871FM) 6 / 2011 Features Bulletin 872C 871TM 871P Size Sensing Range Standard Sensing Range Extended Sensing Range Mode Supply Voltage Proximity Sensors WorldProx Inductive 360 visible LED Nickel-Plated Brass or Plastic Standard and extended sensing models 6.5 mm,,,, Proximity Sensors Inductive Full mechanical seal with leak-proof front end Ideal for heavy duty, metalworking and food applications High enclosure, cleaning resist and washdown rating (82,7 bar / 1200psi) Standard and extended sensing models VersaCube Inductive Sensors Long distance cube type Rugged burn and weld-slag resistand Weld field immune Equal sensing (factor1) models available Inductive Proximity Mounting Brackets Wide variety of metal and plastic mounting brackets Right angle, clamp and spring loaded brackets,,, Cube 40 x 40 mm 2 mm 15 mm 2 mm 15 mm 20 mm 40 mm 2 mm 20 mm 2 mm 40 mm PNP Normally Open Nonshielded 3-wire DC 2-wire AC Cable Micro / Connector 10 30V DC V AC PNP Normally Open Nonshielded 3-wire DC 2-wire AC Cable Micro / Connector 10 30V DC V AC Normally Open Nonshielded 3-wire DC Micro / Connector 10 30V DC Enclosure Rating IP IP 67 IP 67 IP 67 Special enclosure 1,2,3,4,6P,12,13 1,2,3,3R,4,4X,6, 6P,12, psi / 82.7 bar washdown rating 1,2,3,4,6P,12, psi / 82.7 bar washdown rating Approvals UL, c-ul, CE UL, CSA, CE UL, c-ul, CE Product Selection See page 6-23 See page 6-25 See page 6-26 See page 6-26 See page 6-26 See page 6-26 See page Visit our website: Rockwell Automation

2 6 / 2011 Proximity Sensors WorldProx Inductive 3-Wire DC Standard and Short Bulletin 872C 3-conductor, 3- or 4-wire connection Short circuit, overload, false pulse, reverse polarity, and transient noise protection UL listed, cul listed and CE marked for all applicable directives Standard M6.5 2 (0.08) Yes N.O. PNP C-MM1NP7-E2 2 (0.08) Yes N.O. PNP C-D2NP8-E2 Cable 3 (0.12) Yes N.O. PNP C-D3NP12-E2 4 (0.16) No N.O. PNP C-D4NP12-E2 5 (0.20) Yes N.O. PNP C-D5NP18-E2 Pico QD M6.5 2 (0.08) Yes N.O. PNP C-MM1NP7-P3 2 (0.08) Yes N.O. PNP C-D2NP8-D4 3 (0.12) No N.O. PNP C-D3NP8-D4 3 (0.12) Yes N.O. PNP C-D3NP12-D4 4 (0.16) No N.O. PNP C-D4NP12-D4 5 (0.2) Yes N.O. PNP C-D5NP18-D4 8 No N.O. PNP C-D8NP18-D4 Short Cable style style 3 (0.12) Yes N.O. PNP C-DH3NP12-E2 4 (0.16) No N.O. PNP C-DH4NP12-E2 5 (0.2) Yes N.O. PNP C-DH5NP18-E2 8 (0.32) No N.O. PNP C-DH8NP18-E2 10 (0.39) Yes N.O. PNP C-DH10NP30-E2 15 (0.59) No N.O. PNP C-DH15NP30-E2 3 (0.12) Yes N.O. PNP C-DH3NP12-D4 4 (0.16) No N.O. PNP C-DH4NP12-D4 5 (0.20) Yes N.O. PNP C-DH5NP18-D4 8 No N.O. PNP C-DH8NP18-D4 10 (0.39) Yes N.O. PNP C-DH10NP30-D4 15 (0.59) No N.O. PNP C-DH15NP30-D4 DC / Cordset 889D-F4AC-2, see page 4-36 Rockwell Automation Visit our website:

3 Bulletin 872C 3-Wire DC Extended Sensing 3-conductor, 4-wire connection Short circuit, overload, false pulse, reverse polarity, and transient noise protection UL and cul recognized and CE marked for all applicable directives Cable Pico QD style 4 (0.16) Yes N.O. PNP C-M4NP12-A2 8 No N.O. PNP C-N8NP12-A2 8 Yes N.O. PNP C-NP18-A2 12 (0.47) No N.O. PNP C-N12NP18-A2 3 (0.12) Yes N.O. NPN C-M3NP8-P3 4 (0.16) No N.O. NPN C-N4NP8-P3 3 (0.12) Yes N.O. PNP C-M3NP8-D4 4 (0.16) No N.O. PNP C-N4NP8-D4 4 (0.16) Yes N.O. PNP C-M4NP12-D4 8 No N.O. PNP C-N8NP12-D4 8 Yes N.O. PNP C-NP18-D4 12 (0.47) No N.O. PNP C-N12NP18-D4 15 (0.59) Yes N.O. PNP C-M15NP30-D4 20 (0.79) No N.O. PNP C-N20NP30-D4 DC / Cordset 889D-F4AC-2, see page Wire AC 2-wire operation 3-conductor or 3-wire connection V AC (20 240V AC for 8 mm) False pulse and transient noise protection Extended sensing distance on unshielded models CE marked for all applicable directives 6 / 2011 Cable Nominal Sensing Distance [mm (in.)] 1.5 (0.06) Yes C-A1N8-A2 2 (0.08) Yes 872C-A2N12-A2 4 (0.16) No 872C-A4N12-A2 5 (0.20) Yes 872C-A5N18-A2 10 (0.39) No 872C-A10N18-A2 N.O. 15 (0.59) No C-A15N30-A2 2 (0.08) Yes 872C-A2N12-R3 4 (0.16) No 872C-A4N12-R3 5 (0.20) Yes 872C-A5N18-R3 10 (0.39) No 872C-A10N18-R3 AC / ordset 889R-F3ECA-2, see page Visit our website: Rockwell Automation

4 6 / 2011 Proximity Sensors Inductive Bulletin 871TM 3-Wire DC 3-conductor or 4-wire connection Short circuit, overload, false pulse, reverse polarity, and transient noise protection UL listed, CSA certified and CE marked for all applicable directives ToughLink cable style 3-Wire DC Extended Range 3-conductor or 4-wire connection Short circuit, overload, false pulse, reverse polarity, and transient noise protection Equal sensing for both steel and aluminum CE marked for all applicable directives 5 (0.20) Yes N.O. PNP TM-DH5NP18-H2 8 No N.O. PNP TM-DH8NP18-H2 2 (0.08) Yes N.O. PNP TM-DH2NP12-D4 4 (0.16) No N.O. PNP TM-DH4NP12-D4 5 (0.20) Yes N.O. PNP TM-DH5NP18-D4 8 No N.O. PNP TM-DH8NP18-D4 3 (0.12) Yes N.O. PNP TM-M3NP8-D4 6 (0.23) Yes N.O. PNP TM-N6NP8-P3 3 (0.12) Yes N.O. PNP TM-M3NP8-D4 6 (0.23) Yes N.O. PNP TM-N6NP8-D4 6 (0.23) Yes N.O. PNP TM-M6NP12-D4 10 (0.39) No N.O. PNP TM-N10NP12-D4 10 (0.39) Yes N.O. PNP TM-M10NP18-D4 20 (0.79) No N.O. PNP TM-N20NP18-D4 20 (0.79) Yes N.O. PNP TM-M20NP30-D4 40 (1.57) No N.O. PNP TM-N40NP30-D4 DC / Cordset 889D-F4AC-2, see page 4-36 Rockwell Automation Visit our website:

5 Bulletin 871P VersaCube Inductive Sensors 6 / Wire DC VersaCube New rugged housing Weld-field immune models Burn and weld-slag resistant body on weld-field immune models Convenient mounting base 4-pin connection 10 60V DC Short circuit, overload, false pulse, reverse polarity, and transient noise protection UL listed, cul certified and CE marked for all applicable directives Head Size Weld Field Immune Nominal Sensing Distance [mm (in.)] (0.79) Yes N.O. PNP P-D20NP40-D4 No mm 40 (1.57) No N.O. PNP P-D40NP40-D4 DC / Cordset 889D-F4AC-2, see page 4-36 Mounting Brackets for Tubular Proximity Sensors Swivel/Tilt Description Dimensions mm (in) The swivel/tilt mounting bracket provides both axial and 10 tilt adjustment for our 18mm and 30mm tubular-style products (1.1) (0.8) 18 mm and 30 mm Inside Thread (1.15) 28.6 (1.125) (2.0) (2.6) Visit our website: Rockwell Automation

6 6 / 2011 Mounting Brackets for Tubular Proximity Sensors Right Angle Bulletin 872C, 871TM, 871FM, 871C, 871P Proximity Tube [mm (in.)] Dimensions mm (in) Material 8 12 (0.47) 18 (0.71) For use with the 871A- BXN12 or 871A-BXS12 Spring Return Brackets. 30 (01.18) For use with the 871A- BXN30 or 871A-BXS30 Spring Return Brackets (0.08) 3.05 (0.12) 8.74 (0.34) (0.50) 19.1 (0.75) 22.2 (0.87) 30.5 (1.18) 47.5 (1.87) (0.34) (1.50) 13.9 (0.55) (0.62) (2.0) 19.1 (0.75) (0.62) (2.0) 17.4 (0.68) (0.75) (2.5) 23.0 (0.90) (0.75) (3.5) (1.5) 31.8 (1.25) 11.9 (0.46) 34.8 (1.37) (1.37) (1.37) (1.75) 20.6 (0.81) (2.0) (1.25) 15.9 (0.625) (1.50) 19.1 (0.75) (0.4) 44.5 (1.75) 44.5 (1.75) 57.2 (2.25) 34.8 (1.37) 11.2 (0.44) (1.5) 63.5 (2.5) Zinc plated steel Zinc plated steel 871A-BRN8 871A-BRS8 871A-BRN12 871A-BRS12 871A-BRN18 871A-BRS18 871A-BRN22 871A-BRS22 871A-BRN30 871A-BRS30 871A-BRN47 871A-BRS47 Rockwell Automation Visit our website:

7 Bulletin 872C, 871TM, 871FM, 871C, 871P Mounting Hardwareand Chemical Resistant Materialfor Harsh Environment (0.06) Ø 2.4 (0.09) Bracket C Dia. of Proximity Sensor Snap-Clamp Brackets G 12.0 (0.47) Sensor mm Kit includes: (1) Threaded mounting bracket (1) Through-hole mounting bracket (2) x 1 mounting screw (2) x 1 mounting screw (1) Ground terminal lug (1) Green color-coded binding screw D Dimensions mm (inches) C D G (0.72) (0.47) 18.0 (0.71) 30.0 (1.18) 34.0 (1.34) 29.4 (1.16) 48.4 (1.91) 48.3 (1.90) 4 (0.16) 5 (0.20) 6.5 (0.26) 871A-BP4 871A-BP5 871A-BP7 871A-BP8 871A-BP12 871A-BP18 871A-BP30 871A-BP34 Material A-SCBP12 Glass-filled nylon A-SCBP18 Mounting Bracket for VersaCube, Proximity Sensors Description Dimensions mm (in) The mounting kit for VersaCube sensors provides additional mounting flexibility to P VersaCube style sensors. This kit (0.46) includes an accessory mounting bracket that 24.9 (098) allows the VersaCube to bolt in place of existing 871P rectangular and similar competitive sensors. Appropriately sized mounting screws are also supplied. Additionally a ground lug terminal and green (0.67) (0.78) 871A-PKIT 40 (1.58) color-coded binding screw are provided for (1.18) grounding the VersaCube sensor in the event that the unit is not mounted to a grounded 14.2 metal frame. Rockwell_Sensors_Inductive_Proximity_Overview_en_0611.pdf Helsinki tel automation@klinkmann.fi St. Petersburg tel klinkmann@klinkmann.spb.ru Moscow tel moscow@klinkmann.spb.ru Yekaterinburg tel yekaterinburg@klinkmann.spb.ru Samara tel samara@klinkmann.spb.ru Кiev tel klinkmann@klinkmann.kiev.ua Riga tel klinkmann@klinkmann.lv Vilnius tel post@klinkmann.lt Tallinn tel klinkmann.est@klinkmann.ee Мinsk tel minsk@klinkmann.com

NEW. Mallia TM modular. These products are part of Power Line Carrier technology system > See p

NEW. Mallia TM modular. These products are part of Power Line Carrier technology system > See p Mallia TM modular power line carrier (PLC) and infrared (IR) technologies NEW 2818 01 + 2819 00 2818 32 + 2819 05 2818 03 + 2819 00 2818 05 + 2819 00 2818 36 + 2819 05 Technical information (p. 443) Particularly

More information

HELAVIA grommets and mouldings in polychloroprene rubber

HELAVIA grommets and mouldings in polychloroprene rubber A20 HELAVIA grommets and mouldings in polychloroprene rubber HELAVIA grommets and mouldings in POLYCHLOROPRENE rubber (Neoprene) SES-STERLING has modern sophisticated conversion equipment backed by our

More information

PLIO Mouldings in flexible PVC

PLIO Mouldings in flexible PVC PLIO Mouldings in flexible PVC Flexible PVC has long been known as one of the most economical and useful thermoplastic materials, particularly within the electrical industry. Injection moulded parts in

More information

Mouldings in flexible PVC

Mouldings in flexible PVC A22 Mouldings in flexible PVC PLIO Mouldings in flexible PVC Flexible PVC has long been known as one of the most economical and useful thermoplastic materials, particularly within the electrical industry.

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

E3F2 Series DC Cylindrical M18 Photoelectric Sensors to be Discontinued March 2014; Replace with E3FA or E3FB

E3F2 Series DC Cylindrical M18 Photoelectric Sensors to be Discontinued March 2014; Replace with E3FA or E3FB NO: PH-177 PRODUCT: E3F2 DC Photoelectric Sensors DATE: May 2013 TYPE: Partial Discontinuation Notice E3F2 Series DC Cylindrical M18 Photoelectric Sensors to be Discontinued March 2014; Replace with E3FA

More information

Junction Boxes Series 8118

Junction Boxes Series 8118 > Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature

More information

Digital Flow Switch. Series PFM7

Digital Flow Switch. Series PFM7 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow

More information

POWR-BLOKS Distribution/Splicer Blocks and Covers

POWR-BLOKS Distribution/Splicer Blocks and Covers SPECIFICATIONS Voltage : 600V erage: Based on NEC Table 310-16, using 75 C copper wire Material: Phenolic rated at 150 C and Thermoplastic rated at 125 C (LD1400 and LS1300 series only) : Standard: Highly

More information

Electronic relative and differential pressure switch type 616

Electronic relative and differential pressure switch type 616 Electronic relative and differential pressure switch type 616 Pressure range 0... 0.1 25 bar The switching points of the pressure switch type 616 can be potentiometer adjusted by the customer, or set in

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

Inductive Proximity Sensors Global Plus Prox

Inductive Proximity Sensors Global Plus Prox July 2005 PG.05..T. -35 Global Plus ontents Overview................... -35 Model Selection, Sensors...... - Model Selection, ompatible onnector ables........... -37 Model Selection, ccessories... -37

More information

e2c 20 - easy to connect

e2c 20 - easy to connect closer contacts Fieldbus Communications e2c 20 - easy to connect e2c 20 / IP 20 Distributed I/O System for Switch Cabinets Switch cabinets and distribution boxes continue to rely on wiring systems that

More information

OTL Universal terminals

OTL Universal terminals OTL Universal terminals 2019 Universal terminals OTL Universal terminals OTL 1000 V AC/DC Bimetal (AL/CU) Class A Certified according to standards EN 612381 and EN 6094771 2 Universal terminals OTL Universal

More information

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

References 6 k thermal overload relays, adjustable from 0.11 to 16 A s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

DPS-400 SERIES DPH-100 SERIES

DPS-400 SERIES DPH-100 SERIES 745 Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES SERIES General terms and conditions... F- guide... P.699~ Related Information Glossary of terms... P.156~ General precautions... P.1566 PHOTO

More information

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

24 AWG Nano M8 Single Ended and Double Ended Assemblies

24 AWG Nano M8 Single Ended and Double Ended Assemblies 24 AWG M8 Single Ended and Double Ended Abrasion Chemicals Flexing UL Listed CSA IP68 Rated RoHS Compliant 300 V Operating Temperature Range -30 C to 90 C Current Rating: 4 Amps Cord sets made with Trex-Onics

More information

powr-bloks POWR-GARD Fuseblocks Distribution/Splicer Blocks and Covers Applications Connectors Description Ampere Ratings Specifications

powr-bloks POWR-GARD Fuseblocks Distribution/Splicer Blocks and Covers Applications Connectors Description Ampere Ratings Specifications powr-bloks Applications Typical applications include heating, air conditioning and refrigeration systems, el e va tor systems, material handling equipment, control panels, motor controls, switchgear, and

More information

HANGERS & SUPPORTS CLIP-IT CLIP-IT STUD STRAPS BAR JOIST CLIP CONDUIT HANGERS CLIP-IT

HANGERS & SUPPORTS CLIP-IT CLIP-IT STUD STRAPS BAR JOIST CLIP CONDUIT HANGERS CLIP-IT 62 hangers & supports Innovation. It s what Madison is all about. Check out our Madison Strap, the product that started it all. Invented in 1929 by our founder Earl Adkinson, Madison has been on the cutting

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm 0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting

More information

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

Pressure Transmitters 36 F-27839

Pressure Transmitters 36 F-27839 Pressure Transmitters 36 F-27839 SPD310/SPD360 Air Differential schneider-electric.com 37 SPD310/SPD360 SPD310/SPD360 differential pressure transmitters are intended for use in air handling systems for

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type

More information

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54) Series P48 Pressure Controls for Steam, Air or (hot) Water Product Bulletin The series P48 pressure controls are designed as operating or high/low cut-out control on steam, air or (hot) water applications.

More information

Types and approvals. Page 1/6. Data Sheet

Types and approvals. Page 1/6. Data Sheet Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 14 40 35 11 9 5.4 M20 x 1.5 0102 S Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies

More information

GS - Parallel Gripper

GS - Parallel Gripper 11: Double acting Patented backlash adjusting system. Long life and reliability, maintenance free. Different options for fastening. Optional magnetic sensors available on page 517. Spring closed (-NC)

More information

Infrared Linescanners

Infrared Linescanners Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 6 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic. 1 2 Standard Pressure Sensor with display Overview Pressure Range Relative nominal Overload Burst Permitted negative -1..2 bar 2 bar 4 bar 10 bar -1..10 bar 10 bar 20 bar 35 bar 0..2 bar 2 bar 4 bar 10

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 7 36 5 33.5 9 5.4 30 65 0102 Model Number Features Direct mounting on standard actuators Fixed setting Satisfies machinery directive Compact and stable housing EC-Type Examination Certificate

More information

Pressure Transmitter P41

Pressure Transmitter P41 SENSORS FOR AND BIOPHARMA. Product Information P41 Pressure Transmitter P41 Application/Specified usage Pressure measurement in pipes and tanks For process temperatures up to 250 C (428 F) with optional

More information

Data Sheet. P-Series Explosion Proof Pressure Switches

Data Sheet. P-Series Explosion Proof Pressure Switches FEATURES Precision SPDT snap-acting micro switch Setpoint adjustable from 15-100% of range Single or dual adjustable set points Fixed or adjustable deadband Wide selection of switch elements Fixed or adjustable

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 40 35 14 11 9 5.4 M20 x 1.5 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies machinery

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

Introduction. Description. Series P48 Pressure Controls for Steam, Air or (hot) Water. Feature and Benefits

Introduction. Description. Series P48 Pressure Controls for Steam, Air or (hot) Water. Feature and Benefits PSC9626 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin Series Pressure Controls for Steam, Air or (hot) Water Introduction The series pressure controls are designed as operating

More information

Copper Bonded Ground Rod / Grounding Rods / Copper Bonded Earth Rod / Earthing rods

Copper Bonded Ground Rod / Grounding Rods / Copper Bonded Earth Rod / Earthing rods Copper Bonded Ground Rod / Grounding Rods / Copper Bonded Earth Rod / Earthing rods Copper bonded earth rods are made from low carbon Steel. Earth Rods are molecularly bonded with 99.9% pure electrolytic

More information

E2B PROXIMITY SENSORS

E2B PROXIMITY SENSORS E2B PROXIMITY SENSORS Enjoy innovation and reliability today» Time and cost savings» Perfect fit for standard environments» New LITE inductive sensor 2 3 Quality, reliability and value-for-money We asked

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

Accessories. Finger Guards 134. Filter Guards grille 139. Accessories 140. Technology. DC Axial Fans. DC Radial Fans. Specials.

Accessories. Finger Guards 134. Filter Guards grille 139. Accessories 140. Technology. DC Axial Fans. DC Radial Fans. Specials. 13 Technology Finger Guards 134 Filter Guards grille 139 140 Specials DC Axial Fans DC Radial Fans Everything that you need for your fan. ebm-papst provides an extensive range of accessories for optimum

More information

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

F l o w c o n T R o l v a l v E S

F l o w c o n T R o l v a l v E S Composite Right Angle Flow Control Valves Series TMCU-TMVU-TMCO- BSP/METRIC Meter In, Meter Out, Needle Orifice G1/8, G1/, G3/8, G1/2 Banjo flow controllers Nominal diameters Ø 2-3.8-5.8-8 The Meter In,

More information

Filtered compressed air, lubricated or non-lubricated. Maximum torque on each jaw on opening at 87 psi 3.1 in-lbf 10.6 in-lbf 20.

Filtered compressed air, lubricated or non-lubricated. Maximum torque on each jaw on opening at 87 psi 3.1 in-lbf 10.6 in-lbf 20. 2-JAW SELF-CENTERING RADIAL PNEUMATIC GRIPPER (SERIES ) Double-acting. High gripping force at the end of the stroke. Maintenance-free long life and reliability. Various options for fastening. Optional

More information

EX-RECESSED CEILING LIGHT FITTINGS

EX-RECESSED CEILING LIGHT FITTINGS EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic

More information

Miniature controls. Contactors. Overload relays. Starters. Control relays

Miniature controls. Contactors. Overload relays. Starters. Control relays Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power

More information

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6 P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

Flow Sensors & Hydrometers Specification Sheet

Flow Sensors & Hydrometers Specification Sheet Baseline Flow s and Hydrometers Baseline s smart flow sensors and hydrometers are two-wire ready flow measurement and control devices that are pre-programmed with the correct K and Offset values. In addition,

More information

pneumatic power clamps

pneumatic power clamps pneumatic power clamps Features Király Trading KFT H-1151 Budapest Mogyoród útja 12-14 E-mail:_agi@kiralytrading.hu Your requirements Power element of machines, tools and devices for the following applications:

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22. *09005087* DB_BA_EN_ME01_S Rev.A 12/16 *09005087* d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual ME01 Digital manometer Table of Contents ME01 ## # 87 # HL S#### Dust explosion protection

More information

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic FEATURES Adjustable setpoints 15-100% of range Fixed or limited adjustable deadband Wide selection of switch elements Explosion proof enclosure provides uncompromising protection Special designs for NACE

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

RAI-M series RUDDER ANGLE INDICATOR SYSTEM

RAI-M series RUDDER ANGLE INDICATOR SYSTEM RUDDER ANGLE INDICATOR SYSTEM RAI-M series SEAFIRST ENGINEERING CO 45-16, Ga Um Dong, Chang Won, Kyong Nam Korea Tel : 82 55 267 1645 Fax ; 82 55 266 1646 http://www.seafirst.co.kr GENERAL Seafirst Rudder

More information

Pneumatic pressure switch 20DD

Pneumatic pressure switch 20DD Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

Short Form Brochure. Terminal Blocks &Accessories

Short Form Brochure. Terminal Blocks &Accessories Short Form Brochure Terminal Blocks &Accessories 1/2013 AVK - Screw Type Terminal Blocks Connection Systems SCREW CONNECTION : This is the most popular of all known methods of connection. Screw connection

More information

Introduction. P r otective Seals Panel seal for One Hole Mounting (OHM) O-Ring seals for panel mounting Switch boots

Introduction. P r otective Seals Panel seal for One Hole Mounting (OHM) O-Ring seals for panel mounting Switch boots SECTION F Introduction ACCESSORIES Switch Guar d s Prevent accidental operation of switches Switch operation limited to selected functions Adaptable to one, two and four pole config u r a t i o n s One

More information

Metham Aviation Design Limited, Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)

Metham Aviation Design Limited, Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0) Contents Page General Information 1 Items Supplied 1 Variants 1 Compatibility with other products 1 Fitting a Housing 2 Mounting a Bowler 3 Safety Precautions 4 Control Connections 5 Setting up a Bowler

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 Data sheet Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 The CCMT is an electrically operated valve designed specifically for operation in CO 2 systems. The CCMT valve concept is

More information

Hand lever valves VHER

Hand lever valves VHER Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:

More information

Conductor Bushings Series 8174

Conductor Bushings Series 8174 > Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media FEATURES 50 mbar to 400 bar, 5 to 6000 psi gage or absolute pressure For many industrial gases and liquids 00, 0545, 05, 6 or 40 ma output Field interchangeable EMC according to EN 66-8 MEDIA COMPATIBILITY

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element

More information

TeSys protection components

TeSys protection components Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER . ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal

More information