1 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the requirements of applicable codes and standards. This activity is coupled with periodic surveillance of the supplier's factory and warehouses as well as the assessment of the supplier's Quality Assurance System. This listing is subject to the conditions set forth in the characteristics below and is not to be construed as any recommendation, assurance or guarantee by IAPMO Research and Testing, Inc. of the product acceptance by Authorities Having Jurisdiction. The most updated information on this Certificate of Listing is available online at pld.iapmo.org Effective Date: January 2018 Void After: January 2019 Dba: Wdi Plbg. Inc. & Wdi Intl 3 Musick Irvine, CA Identification: Manufacturer's name or trademark, model name or number (or part number), and critical level shall be permanently and legibly marked so as to be visible after installation. The product shall also bear the cupc certification mark. Characteristics: Anti-Siphon type flush tank fill valves to be installed in accordance with the manufacturer's instruction and the requirements of the latest edition of the Uniform Plumbing Code. Products listed on this certificate have been tested by an IAPMO R&T recognized laboratory. This recognition has been granted based upon the laboratory's compliance to the applicable requirements of ISO/IEC Products are in compliance with the following code(s): Uniform Plumbing Code (UPC ) National Plumbing Code of Canada International Plumbing Code (IPC ) This listing period is based upon the last date of the month indicated on the Effective Date and Void After Date shown above. Any change in material, manufacturing process, marking or design without having first obtained the approval of the Product Certification Committee, or any evidence of non-compliance with applicable codes and standards or of inferior workmanship, may be deemed sufficient cause for revocation of this listing. Production of or reference to this form for advertising purposes may be made only by specific written permission of IAPMO Research and Testing, Inc. Any alteration of this certificate could be grounds for revocation of the listing. This document shall be reproduced in its entirety.

2 Products are in compliance with the following standard(s): ASSE /ASME A /CSA B

3 MODELS: B1025 B1026 B1030 B1046 B1048 B2026 B2046 B2048 B3026 B3046 B3048 B3111 B3121 B3200 B3260 B3300-X B3310E B3310Y B3500 B3700 B3800L B3800W B3831E B3831L B3831W B3832E B3832L B3832W B3833L B3833W B3834E B3834L B3834W B3835L B3835W B3836L B3836W Description Adjustable Height 8" Screw down toilet fill valve Non-adjustable height anti-siphon fill valve 8" Snap-Cap Fill Valve 8.5" Snap-Cap w/ POM Float Rod 10" Screw down toilet fill valve 10" Snap-Cap fill valve 10" Snap-Cap w/ POM Float Rod 12" Rigid, fixed height shaft 12" Snap-Cap fill valve w/float rod, Anti-Siphon 12" Snap-Cap w/ POM Float Rod 11" Pilot type fill valve 9" 14" Adjustable Pilot type fill valve Side mount anti-siphon fill valve Adjustable Height Shank Plastic anti-siphon with E= 32 mm CL Adjustable Height Shank Plastic anti-siphon with Y= 55 mm CL Adjustable Height plastic Anti-siphon fill valve Adjustable height anti-siphon fill valve 7" overall height w/ a 6" C/L Fixed Shank 8" Fixed Shank Anti-siphon fill valve 8" Fixed Shank Anti-siphon fill valve 8" overall height w/ a 7" C/L Fixed Shank 7" Fixed Shank Anti-siphon fill valve 7" Fixed Shank Anti-siphon fill valve 9" Fixed Shank Anti-siphon fill valve 9" Fixed Shank Anti-siphon fill valve 9" overall height w/ 8" C/L shank 10" Fixed Shank Anti-siphon fill valve 10" Fixed Shank Anti-siphon fill valve 11" Fixed Shank Anti-siphon fill valve 11" Fixed Shank Anti-siphon fill valve 12.5" Fixed Shank Anti-siphon fill valve 12.5" Fixed Shank Anti-siphon fill valve B3800 and B3800E adjustable height B3833 and B3833E fixed shank, 10.75" height B3834 and B3834E Fixed Shank 8.75" height B3835 and B3835E fixed shank, 13" height Page 3 of 6

4 B3836 and B3836E 14/25" height B3200-C (Fill Valve Side Mount ) W3910 Fill Valve Suffixes: X = M adjustment bottom-in fill valve = Y non-adjustment bottom-in fill valve Page 4 of 6

5 ADDITIONAL COMPANY INFO: Axent B3910 Description Fill Valve Gerber Plumbing Fixtures Corporation PN Description Adjustable height Kohler Company Description Non-adjustable height anti-siphon fill valve Larsen Supply Company Description PN " Snap-Cap w/ POM Float Rod PN " Snap-Cap w/ POM Float Rod PN " Snap-Cap w/ POM Float Rod PN Adjustable Height Adjustable Height Toto USA Inc. Description B3833E Fixed shank, 10.75" height B3834E Fixed Shank 8.75" B3835E Fixed shank, 13" height *NOTE: TOTO Models may be listed with G-Max or Power Gravity embossed on the cap cover Waxman Industries, Inc. - Consumer Product Group Pilot Pin Style Water Closet Fill Valve CPG & 410 & 450 CPG & 510 & 550 Snap On Cap Ballcocks Page 5 of 6

6 CPG & 610 & 650 CPG & 712 & 750 Screw Cap Ballcocks CPG CPG A CPG 3026 Oatey Company Description " Snap-Cap fill valve w/float rod, Anti-Siphon Page 6 of 6

Effective Date: May 2017 Void After: May Product: Press and Nail Connections File No. M-8332

Effective Date: May 2017 Void After: May Product: Press and Nail Connections File No. M-8332 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: not available -Rev. 12/1/2017- Void After: Product: Water Closets with Dual Flush Feature File No. 5645

Effective Date: not available -Rev. 12/1/2017- Void After: Product: Water Closets with Dual Flush Feature File No. 5645 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: December 2017 Void After: December 2018

Effective Date: December 2017 Void After: December 2018 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: October 2017 Void After: October Product: Ceramic Plumbing Fixtures File No. 2467

Effective Date: October 2017 Void After: October Product: Ceramic Plumbing Fixtures File No. 2467 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: February 2018 Void After: February Product: Bathtubs (Plastic) File No. 3638

Effective Date: February 2018 Void After: February Product: Bathtubs (Plastic) File No. 3638 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: April 2018 Void After: April 2019

Effective Date: April 2018 Void After: April 2019 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Suction fittings for use in swimming pools, wading pools, spas, hot tubs, and other aquatic facilities.

Suction fittings for use in swimming pools, wading pools, spas, hot tubs, and other aquatic facilities. IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: July 2016 Void After: July Product: ABS-DWV Pipe and Fittings File No. 9266

Effective Date: July 2016 Void After: July Product: ABS-DWV Pipe and Fittings File No. 9266 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: May Rev. 6/18/2018- Void After: May Product: Plumbing Fixture Fittings File No. 3489

Effective Date: May Rev. 6/18/2018- Void After: May Product: Plumbing Fixture Fittings File No. 3489 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

California Lead Plumbing Law Devices and Components

California Lead Plumbing Law Devices and Components IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: July 2018 Void After: July Product: Plumbing Fixture Fittings File No. 4155

Effective Date: July 2018 Void After: July Product: Plumbing Fixture Fittings File No. 4155 IAPMO Researh and Testing, In. is a produt ertifiation body whih tests and inspets samples taken from the supplier's stok or from the market or a ombination of both to verify ompliane to the requirements

More information

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings Presented to the IAPMO Standards Review Committee on October 15, 2018 General: The changes to this standard

More information

EVALUATION SUBJECT: PUSH FIT FITTINGS DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING. Report Holder:

EVALUATION SUBJECT: PUSH FIT FITTINGS DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING. Report Holder: ICC-ES Report PMG-1149 Reissued 08/2017 This report is subject to renewal 08/2018 EVALUATION SUBJECT: PUSH FIT FITTINGS DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING Report Holder:

More information

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS DIVISION: PLUMBING SECTION: SANITARY WASTE AND VENT PIPING.

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS DIVISION: PLUMBING SECTION: SANITARY WASTE AND VENT PIPING. ICC-ES Report PMG-1407 Reissued 10/2017 This report is subject to renewal 10/2018 EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS DIVISION: 22 00 00 PLUMBING SECTION: 22 13 16 SANITARY WASTE AND VENT

More information

Effective Date: February Rev. 7/13/2018- Void After: February Product: Plumbing Fixtures (Stainless Steel) File No.

Effective Date: February Rev. 7/13/2018- Void After: February Product: Plumbing Fixtures (Stainless Steel) File No. IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

A112 STANDARDS STATUS REPORT

A112 STANDARDS STATUS REPORT A112 STANDARDS STATUS REPORT DESIGNATION & TITLE STATUS RESPONSIBILITY A112.1.2 2012 (R2017) Air Gaps in Plumbing Systems (For Plumbing Fixtures and Water- Connected Receptors) RC #08-1056, PINS #284 LB

More information

ASSE International Product (Seal) Listing Program

ASSE International Product (Seal) Listing Program Manufacturer Contact Person Address ASSE International Product (Seal) Listing Program ASSE 07-05 / ASME A.9.07-05 / CSA B5.7-5 Pressurized Flushing Devices for Plumbing Fixtures Laboratory File Number

More information

FLUSHMATE FLUSHOMETER - TANK SYSTEM. 501-A Series. Owner s Service Manual. 501-A Series

FLUSHMATE FLUSHOMETER - TANK SYSTEM. 501-A Series. Owner s Service Manual. 501-A Series Owner s Service Manual 501-A Series FLUSHMATE FLUSHOMETER - TANK SYSTEM 501-A Series A Division of Sloan Valve Company 30075 Research Drive New Hudson, MI 48165 800-533-3450 248-446-5300 http://www.flushmate.com

More information

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series Owner s Service Manual 503 Series FLUSHMATE III FLUSHOMETER - TANK SYSTEM 503 Series FLUSHMATE A Division of Sloan Valve Company 30075 Research Drive New Hudson, MI 48165 800-533-3450 248-446-5300 http://www.flushmate.com

More information

Parts Manual. Frusheez Machines

Parts Manual. Frusheez Machines Parts Manual Frusheez Machines Model No. 1414 and 1416 Model 1414 Model 1416 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA Part No. 110007 ORDERING SPARE PARTS 1. Identify the needed part by checking

More information

ASSE International Product (Seal) Listing Program

ASSE International Product (Seal) Listing Program ASSE International Product (Seal) Listing Program ASSE 1070-2015 / ASME A112.1070-2015 / CSA B125.70-15 Performance Requirements for Water Temperature Limiting Devices Manufacturer: Contact Person: E-mail:

More information

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC 157-20067 1 PURPOSE 1.1 The purpose of this standard is to establish an acceptable standard

More information

EVALUATION SUBJECT: PUSH FIT FITTINGS DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING. Report Holder:

EVALUATION SUBJECT: PUSH FIT FITTINGS DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING. Report Holder: ICC-ES Report PMG-1256 Reissued 10/2017 This report is subject to renewal 06/2018 EVALUATION SUBJECT: PUSH FIT FITTINGS DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING Report Holder:

More information

Originally Issued: 10/08/2010 Revised: 10/27/2017 Valid Through: 10/31/2018

Originally Issued: 10/08/2010 Revised: 10/27/2017 Valid Through: 10/31/2018 ITW BUILDING COMPONENTS GROUP INC. ITW ALPINE HANGERS AND ANCHORS CSI Section: 06 05 23 Wood, Plastic and Composite Fastenings 1.0 RECOGNITION ITW Alpine Hangers and Anchors recognized in this report has

More information

Presented to the IAPMO Standards Review Committee on March 7, 2016

Presented to the IAPMO Standards Review Committee on March 7, 2016 Summary of Substantive Changes between the 2015 edition of ASSE 1070/ASME A112.1070/CSA B125.70, Water Temperature Limiting Devices, the 2004 edition of ASSE 1070, Water Temperature Limiting Devices, and

More information

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HVAC DUCTS AND CASINGS.

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HVAC DUCTS AND CASINGS. ICC-ES Report PMG-1171 Reissued 11/2018 This report is subject to renewal 11/2019 EVALUATION SUBJECT: UNDERGROUND SINGLE WALL & DOUBLE WALL INSULATED DUCT FOR HVAC DIRECT BURIAL APPLICATIONS AND UNDERGROUND

More information

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment OPERATOR S MANUAL FOR MORSE TILT-TO-LOAD DRUM ROTATOR SAFETY INFORMATION: While Morse Manufacturing Co. drum handling equipment is engineered for safety and efficiency, a high degree of responsibility

More information

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20808 General Information 2 Technical Data 3 Dimensions 4 A-20809 Non-Adjustable Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500 Operators Manual Supera Wall Mount Anesthesia Machines Models: M2300 M2500 (All shown with optional equipment) M2300 M2500 Examination and Preparation for Use Thank you for ordering an Supera Anesthesia

More information

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Index Table. Model 794. Installation, Operating and Maintenance Instructions CLOCKWISE MANUAL MAKING INTO CCW TABLE Index Table Model 794 Installation, Operating and Maintenance Instructions Black & Webster Products Division 545 Hupp Ave. P.O. Box 831, Jackson, Michigan 49204 2009

More information

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings

More information

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200 Operators Manual Supera Floor Stand Anesthesia Machine Models: M1000 Basic Non-rebreathing M1200 Basic M1000 M1200 (All shown with optional equipment) Copyright Supera, LLC 2017 Examination and Preparation

More information

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20806 A-20807 Adjustable General Information 2 Technical Data 3 Dimensions 4 Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

DIVISION: 06--WOOD AND PLASTICS SECTION: Wood, Plastic and Composite Fastenings

DIVISION: 06--WOOD AND PLASTICS SECTION: Wood, Plastic and Composite Fastenings DIVISION: 06--WOOD AND PLASTICS SECTION: 060523 -- Wood, Plastic and Composite Fastenings REPORT HOLDER: ITW BUILDING COMPONENTS GROUP, INC. 2400 LAKE ORANGE DRIVE, SUITE 150 ORLANDO, FLORIDA 32837 (800)

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT ALPKT57- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... Table of Contents INSTALLATION

More information

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS Procedure-assembly-functional test and performance requirements 1 SCOPE 1.1 This document establishes the general procedure for assembly, functional testing and normal performance requirements of low Series

More information

FLUSHMATE FLUSHOMETER - TANK SYSTEM

FLUSHMATE FLUSHOMETER - TANK SYSTEM FLUSHMATE FLUSHOMETER - TANK SYSTEM Owner s Service Manual 501-B and 503 Series 501-B 503 FLUSHMATE A Division of Sloan Valve Company 30075 Research Drive New Hudson, MI 48165 800-533-3460 248-446-5300

More information

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09 Installation & Maintenance Instructions TEC-11N TIMER Analogue electronic timer 02/09 GENERAL OPERATION The TEC-11N timer is produced using SMT (Surface Mounting Technology), ensuring improved performance

More information

Originally Issued: 10/08/2010 Revised: 10/30/2015 Valid Through: 10/31/2016

Originally Issued: 10/08/2010 Revised: 10/30/2015 Valid Through: 10/31/2016 EVALUATION SUBJECT: ITW ALPINE HANGERS AND ANCHORS REPORT HOLDER: ITW Building Components Group Inc. 13825 W. Business Center Dr. Unit A Lake Forest, IL 60045 (800) 521-9790 www.alpineitw.com CSI Division:

More information

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions Compact Triple Cabinet Outlet Station Model 6258-1 Installation and Operating Instructions The Porter Compact Triple Outlet Station (6258-1) provides a quick, safe, and reliable method of connection to

More information

OWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01

OWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01 DUAL CONTROL THERMOSTATIC SHOWER VALVE Shower Control Handles and Concealing Plate may differ depending on choice of Model OWNER S GUIDE ISSUE 01 These instructions cover all exposed or concealed versions

More information

IAPMO IS PUBLIC REVIEW DRAFT Thrust Blocking for Rubber Gasketed and Solvent Cement Joints

IAPMO IS PUBLIC REVIEW DRAFT Thrust Blocking for Rubber Gasketed and Solvent Cement Joints IAPMO IS 33-2019 PUBLIC REVIEW DRAFT Thrust Blocking for Rubber Gasketed and Solvent Cement Joints IAPMO Standard IAPMO IS 33 2019 Published: Month Year Published by International Association of Plumbing

More information

Yoke Block Instruction Manual

Yoke Block Instruction Manual Yoke Block Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These

More information

Model 9201E Tempered Water Blending System

Model 9201E Tempered Water Blending System INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9201E Tempered Water Blending

More information

Title: Pressure Relieving and Venting Devices Function: Ecology & Safety No.: BC Page: 1 of 7 Reviewed: 6/30/12 Effective: 7/1/12 (Rev.

Title: Pressure Relieving and Venting Devices Function: Ecology & Safety No.: BC Page: 1 of 7 Reviewed: 6/30/12 Effective: 7/1/12 (Rev. Preparer: Team Member, North America, Process Safety Center of Expertise No.: BC032.020 Page: 1 of 7 Owner: Manager, North America Process Safety Center of Expertise Approver: Sr. Vice President, Ecology

More information

Engineering Excellence. Installation Guide

Engineering Excellence. Installation Guide Engineering Excellence Installation Guide Two Handle Kitchen Faucet: 2DM200 2DM201 This product meets the following standards: ASME A112.18.1 ANSI A117.1 ANSI / NSF 61, SECTION 9 CUPC / IAPMO LISTED /

More information

Form No. P Meter, PD Series H8-S3 Flat Plate Cover Parts List

Form No. P Meter, PD Series H8-S3 Flat Plate Cover Parts List Form No. P0550.50 Meter, PD Series H8-S3 Flat Plate Cover Parts List Issue/Rev. 0.0 (10/04) Bulletin P0550.50 The Most Trusted Name In Measurement Inner Mechanism Page P0550.50 Issue/Rev. 0.0 (10/04) Item

More information

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS Wastewater combination air valve in Mod. SCS The air valve guarantees the proper operation of sewage/industrial lines allowing the entrance of large quantity of air in case of pipe bursting or draining,

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 14 40 35 11 9 5.4 M20 x 1.5 0102 S Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies

More information

Masoneilan* Model 78-80H & 08-80H Transfer Valves

Masoneilan* Model 78-80H & 08-80H Transfer Valves GE Oil & Gas Masoneilan* Model 78-80H & 08-80H Transfer Valves Instruction Manual GE Data Classification: Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE

More information

GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES

GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES ESYD G-DIAKRIB/01/01/26-03-2015 1/6 ESYD G-DIAKRIB Issue: 01 Revision: 01 Issue Date: 28-11-2007

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance Document Authority: EHS Coordinator Document Custodian: EH&S Coordinator Effective Date: 09.01.15 Issuing Dept: College

More information

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT! Guardian Fall Protection Kent, WA 800-466-6385 www.guardianfall.com GENERAL SYSTEM SELECTION CRITERIA: Selection of fall protection shall be made by a Competent Person. All fall protection equipment shall

More information

ATEX ATEX

ATEX ATEX OPERATING MANUAL: HIGH-PERFORMANCE PUMP HEAD Model Nos. MASTERFLEX L/S 77252-62 77252-60 77252-62 77252-70 77252-72 77252-80 ATEX 77252-82 ATEX A-1299-7353 Edition 01 (US & Canada only) Toll Free 1-800-MASTERFLEX

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 40 35 14 11 9 5.4 M20 x 1.5 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies machinery

More information

GAS SAFETY Information Bulletin

GAS SAFETY Information Bulletin GAS SAFETY Information Bulletin June 2016 G-03-11-ABSA [Rev2] Page 1 of 7 Fuel Gas Pressure Piping in Plants This bulletin has been jointly developed by Safety Services, the Pressure Equipment Sub- Council,

More information

The OCV Series 8000 float control valves are designed to maintain a SERIES FEATURES

The OCV Series 8000 float control valves are designed to maintain a SERIES FEATURES The OCV Series 8000 float control valves are designed to maintain a desired level in a tank or reservoir by opening for filling the tank when fluid is below the high level point and closing tightly when

More information

installation instructions

installation instructions installation instructions GAS CONVERSION KIT PROPANE-TO-NATURAL P/N 315572-71201 4GAD 6GAD Cancels: IIK 4G-50-4 IIK 4G-50-5 7/15/91 NOTE: Read the entire instructions before starting the installation.

More information

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1 NPT (Typ. Both Ends 2 Places) MODEL Float Control For Closed Tanks Accurate Liquid Level Control Fully Hydraulic Operation Simple Design, Easy Maintenance No Lubrication Necessary No Gears, No Mechanical Linkage Between Valve and Control

More information

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 8655-4 First edition 2002-09-15 Piston-operated volumetric apparatus Part 4: Dilutors Appareils volumétriques à piston Partie 4: Diluteurs Reference number ISO 8655-4:2002(E)

More information

Effective Date: October Rev. 1/29/2018- Void After: October Product: Lead Free Plumbing Products File No. 6544

Effective Date: October Rev. 1/29/2018- Void After: October Product: Lead Free Plumbing Products File No. 6544 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Decorative Accessories Guide

Decorative Accessories Guide Decorative Accessories Guide Monogram Brass is a trademark of Ferguson Enterprises, Inc. Monogram Brass Finishes Brushed Nickel* (BN) Oil Rubbed Bronze (ORB) Polished Brass* (PB) Chrome (CP) Biscuit (BISC)

More information

Emergency Shower & Eyewash. Training Guide

Emergency Shower & Eyewash. Training Guide Emergency Shower & Eyewash Training Guide No matter how many precautions employees take, accidents sometimes happen. In these situations quick action is essential, and if the incident involves a hazardous

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

CAST IRON SAFETY VALVE TYPE 6301

CAST IRON SAFETY VALVE TYPE 6301 CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a

More information

FLOAT OPERATED LEVEL CONTROLLER

FLOAT OPERATED LEVEL CONTROLLER PNEUMATIC LEVEL SWITCH NO RELAY APPLICATION: Liquid level controller for oil and gas separators, water knockouts, gas scrubbers and accumulators. FEATURES: Push-button dump valve override standard Float

More information

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process Now you can safely control your filtering process BROCHURE C1 SAFEsystem TM Safety Apparatus Filter Enhancement Available on Individual, Duplex or Multi-Housing ASME Code filter systems. Filtration Systems

More information

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Steam Trap BK BK 212-ASME. Original Installation Instructions English Steam Trap BK 212.. BK 212-ASME EN English Original Installation Instructions 810609-02 1 Contents Page Important Notes Usage for the intended purpose... 3 Safety note... 3 Danger... 3 Attention... 3 Application

More information

FLOAT OPERATED LEVEL CONTROLLER

FLOAT OPERATED LEVEL CONTROLLER PNEUMATIC LEVEL SWITCH APPLICATION: Liquid level controller for oil and gas separators, water knockouts, gas scrubbers and accumulators. FEATURES: Rated for 2000 psi working pressure Push-button dump valve

More information

FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE. Gary S. Beckett

FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE. Gary S. Beckett FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE Gary S. Beckett Flow Safe Supply 10727 Tower Oaks Boulevard Houston, Texas 77070 What Are They and Why Are They

More information

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society Guideline No.M-05(201510) M-05 AIR COMPRESSOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable technical requirements

More information

Specification For Water Meters. Pr10068

Specification For Water Meters. Pr10068 Specification For Water Meters Pr10068 Documents Details This document is only valid on the day it was printed. Version Review Revision Date issued Reviewed by Approved by Date approved Revision type 0.1

More information

GENERAL NOTES FOR SWIMMING POOLS AND SPAS

GENERAL NOTES FOR SWIMMING POOLS AND SPAS GENERAL NOTES FOR SWIMMING POOLS AND SPAS 1. Buried Poly Ethylene (PE) pipe gas lines shall be 18 below finish grade or in an approved recessed channel with 14 gauge insulated tracer wire; Galvanized malleable

More information

Read through all the steps first before working on the camera. Make sure you know what to do.

Read through all the steps first before working on the camera. Make sure you know what to do. Step-by-step procedure to fix lack of contact in the end-of-travel switch of a D700 pop-up flash DISCLAIMER: PLEASE UNDERSTAND THAT IF YOU DECIDE TO FOLLOW THE INFORMATION PROVIDED BELOW YOU DO SO AT YOUR

More information

OPERATION and MAINTENANCE Guide

OPERATION and MAINTENANCE Guide Catalog No. AIR1000 Winch and Hoist OPERATION and MAINTENANCE Guide Cat. No. AIR1000 1250 Lb. Single Line Pull READ THIS BEFORE OPERATING UNIT INSTALLATION: Mount on clean, flat surface. Use 1/2" mounting

More information

Bulletin /06/2012 Supersedes 10/23/00. Installation of John Crane Type 73 Inflatable Mechanical Seal. Page 01 of 10

Bulletin /06/2012 Supersedes 10/23/00. Installation of John Crane Type 73 Inflatable Mechanical Seal. Page 01 of 10 01 of 10 1. Carefully read all instructions and notes before installation. 2. Bench Pre-assembly: a. Insert the support ring (item #1) inside the inflatable boot (item #2) to form inflatable seal assembly

More information

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014 User Manual 1 P a g e Rev. V1.6-EN 11/08/2014 Copyright Disclaimer Trademarks and patents Intended use Contact info 2011 Inflotrolix, Inc. This document may not be copied in whole or in part or otherwise

More information

Decorative Accessories Guide

Decorative Accessories Guide Decorative Accessories Guide Monogram Brass is a trademark of Ferguson Enterprises, Inc. Monogram Brass Finishes Brushed Nickel* (BN) Oil Rubbed Bronze (ORB) Polished Brass* (PB) Chrome (CP) Biscuit (BISC)

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

THERMOSTATIC MIXING VALVES

THERMOSTATIC MIXING VALVES THERMOSTATIC MIXING VALVES D1088 & D1089 INTRODUCTION Are self-acting Thermostatic Mixing Valves designed to blend hot and cold water, to ensure a constant, safe outlet temperature and prevent scalding.

More information

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public GE Oil & Gas 77-6 Model Masoneilan* Air Lock-up Valve Instruction Manual GE Data Classification : Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE INFORMATION

More information

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions PORTER Parker Hannifin Corporation Porter Instrument Division 245 Township Line Rd. P.O. Box 907 Hatfield, PA 19440-0907 USA (215) 723-4000 / fax (215) 723-5106 Compact Triple Cabinet Outlet Station Model

More information

Installation Instructions

Installation Instructions Installation Instructions COLONY SOFT 7.0 Centerset Lavatory Faucet 7.0 with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a features found

More information

WaterSource Heat Pump Hose Kit Performance Specification-Summary

WaterSource Heat Pump Hose Kit Performance Specification-Summary WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo

More information

GAS FRYER Instruction Manual Model #5099NS

GAS FRYER Instruction Manual Model #5099NS Part No. 89932 Revised: March 2004 GAS FRYER Instruction Manual Model #5099NS Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS GAS FUNNEL CAKE FRYER 2 MODEL #5099NS GAS FUNNEL CAKE FRYER SAFETY PRECAUTIONS

More information

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS 6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS USER MANUAL -1- SI-BARNET DEADWEIGHT TESTER 6000 SERIES Release: S31-0250 Revision: A Date: 05/08/03 MANUFACTURED BY: GE RUSKA RUSKA INSTRUMENT CORPORATION 10311

More information

HOA Specifications and User Guidelines for Hot Tubs at WW3HOA

HOA Specifications and User Guidelines for Hot Tubs at WW3HOA HOA Specifications and User Guidelines for Hot Tubs at WW3HOA The purpose of this document is to provide all unit owners with city codes and HOA specifications and guidelines for installing hot tubs within

More information

Anti-flood device Model B-1

Anti-flood device Model B-1 December 4, 2009 Dry Systems 123a 1. DESCRIPTION The Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET

More information

LH 050 / 150 /250 FLIGHT HELMET

LH 050 / 150 /250 FLIGHT HELMET LH 050 / 150 /250 Flight Helmet Instruction Manual Page 1 of 14 CGF GALLET LH 050 / 150 /250 FLIGHT HELMET Instruction Manual ENGLISH Compiled into PDF Format by Flight Helmets Australia Specialising in

More information

INSTRUCTION MANUAL. Gas Salamander

INSTRUCTION MANUAL. Gas Salamander INSTRUCTION MANUAL Gas Salamander This manual contains important information regarding your unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply

More information

SETUP INSTRUCTIONS SX-F EU 250 SX-F USA

SETUP INSTRUCTIONS SX-F EU 250 SX-F USA SETUP INSTRUCTIONS 2010 250 SX-F EU 250 SX-F USA Art. no. 3211544en INTRODUCTION 1 INTRODUCTION The work described in these setup instructions must be performed before the vehicle is delivered to the

More information

Yoke Block Instruction Manual

Yoke Block Instruction Manual Yoke Block Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These

More information

SERIES SAFETY VALVE

SERIES SAFETY VALVE R Manufactured by Conbraco Industries, Inc. 10-600 SERIES SAFETY VALVE INSTALLATION, OPERATION, & MAINTENANCE Part I Document Number: ES-1325 Revision Level: B Issued By: T.HAMILTON Date: 3/3/16 Approved

More information

PRO SINK -R 1 and 2. Dilution system CONTENTS

PRO SINK -R 1 and 2. Dilution system CONTENTS PRO SINK -R 1 and 2 Dilution system CONTENTS 1.0 Product description 2 2.0 Warnings.. 3 3.0 Installation procedure 4 4.0 Plumbing connections 4 5.0 Technical features.. 5 6.0 Maintenance... 6 7.0 Troubleshooting......6

More information

North American Pressure Switches

North American Pressure Switches Combustion North American Pressure Switches Bulletin 8757 Pressure switches are used with Automatic Shutoff Valves or Solenoid Valves to interrupt fuel flow in the event of fuel or air failure. They are

More information

Installation Instructions

Installation Instructions Installation Instructions BW Seals Uniseal Series Cartridge metal bellows single and dual seals Experience In Motion Description The Uniseal metal bellows seal series consists of: Uniseal I - Single seals

More information

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1* INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1* THIS KIT CONTAINS: AOPS7741 (NATURAL TO PROPANE CONVERSION PARTS FOR MODEL SIZE, 50) AOPS7742(NATURAL

More information