HP Integrity Superdome 2

Size: px
Start display at page:

Download "HP Integrity Superdome 2"

Transcription

1 Total System Cost $1,703,613 USD Database Size HP Integrity Superdome 2 Composite Query per Hour Metric 140,181.1 QphH@1000GB Database Manager Operating System Price/Performance $12.15 USD Price/QphH@1000GB Other Software Availability Date Oracle Database 11g R2 Enterprise Edition with HP-UX 11i v GB Partitioning and Oracle September 2010 None 10/20/2010 Automatic Storage Management Update Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 Q12 Q13 Q14 Q15 Q16 Q17 Q18 Q19 Q20 Q21 Q22 RF1 RF2 Power Test Throughput Test Arithmetic Mean of Throughput Test Geometric Mean of Power Test Database Load Time = 01:04:41 Total Data Storage/Database Size = Query times in seconds Load Includes Backup: N Memory/Database Size Percentage = 51.2% Storage Redundancy Level 1 for Base Tables, Auxiliary Data Structures, DBMS temporary space, and OS and DBMS Software System Configuration Number of Nodes: 1 Processors/Cores/Threads/Type: 16/64/64/Intel Itanium Ghz, 24MB il3 cache Memory: 512 GB Disk Drives: 24 HP MSA 2324 with a total of 576, 72GB disks 1 HP MSA 2324 with a total of 4, 146GB disks Total Disk Storage 42056GB (In this number one GB is defined as 1024*1024*1024 bytes) Lan Controllers 16 Embedded LAN Cards

2 Description Part Number Source Reference Price Qty Extended Price 3 yr Maint Price Server Hardware HP Superdome 2-16s Server** AH337A 1 56, ,500 HP CB900s i2 1.86GHz/24MB Cell Blade** AM253A 1 44, ,000 HP DDR3 512GB (32x16GB) Memory Bundle** AH407A 1 112, ,000 HP 3y Support Plus 24 SVC - SD2-16s hw/sw** HA110A , ,742 HP Superdome 2 IOX Enclosure** AH338A 1 11, ,400 HP ProCurve 6120XG Blade Switch AT064A 1 9, ,000 HP Universal Rack G2 Shock Rack AF002A 1 1, ,489 HP 16A High Voltage Modular PDU B HP 17" FlatPanel Monitor GV537A HP USB Keyboard GM321AA#ABA HP Optical 4 Button USB Mouse EW208AA#ABA Subtotal 579, ,742 Server Software Oracle Database 11g Release 2 Enterprise Edition, Named User Plus for 3 years 2 11, ,000 Partitioning, Named User Plus for 3 years 2 2, ,000 Oracle Incident Server Support Packag for 3 years 2 6, ,900 PSL HP-UX 11i Integrity 16Skt/4Core BOE LTU BA927AC# , ,200 DVD media BA927AA#AJR Subtotal 559,765 6,900 Storage 5m Fibre Channel Cables B ,880 HP 2324fc DC Modular Smart Array AJ797A 1 8, ,500 37,825 HP PCIe 2-port 8Gb FC SR (Qlogic) HBA AH401A 1 4, ,288 HP 146GB 3G SAS 10K 2.5in DP ENT HDD B ,076 HP 72GB 3G SAS 15K 2.5in DP ENT HDD B ,024 HP Universal Rack G2 Shock Rack AF002A 1 1, ,978 HP 16A High Voltage Modular PDU B ,196 HP 8/24 Base 16-ports Enabled SAN Switch AM868A 1 6, , HP 8Gb Shortwave B-series FC SFP+ 1 Pack AJ716A ,988 Subtotal 670,829 38,788 Total 1,809, ,430 Oracle Mandatory E-Business Discount on (Licenses and Support) (95,780) 23 % Large Configuration Discount and Support Prepayment* (275,194) (102,575) Grand Total 1,438, ,855 *All discounts are based on US list prices and for similar quantities and configurations 3-yr Cost of Ownership: 1,703,613 ** These components are not immediately orderable. See FDR for more information QphH@1000GB: 140,181 Source 1=HP, 2=Oracle $/QphH@1000GB: Audited By: Francois Raab for InfoSizing ( ( Prices used in TPC benchmarks reflect actual prices a customer would pay for a one-time purchase of the stated components. Individually negotiated discounts are not permitted. Special prices based on assumptions about past or future purchases are not permitted. All discounts refelect standard pricing policies for the listed components. For complete details, see the pricing sections of the TPC benchmark specifications. If you find the stated prices are not available according to these terms, please inform the TPC at pricing@tpc.org. Thank you.

3 Measurement Results Database Scaling (SF/size) 1000 Total Data Storage/Database Size Memory/Database Size Percentage 51.20% Start of Database Load Time 04/13/10 09:51:16 End of Database Load Time 04/13/10 10:55:57 Database Load Time 1:04:41 Query Streams for Throughput Test (S) 64 TPC-H Power 139,181.0 TPC-H Throughput 141,188.3 TPC-H Composite Query-per-Hour Metric 140,181.1 Total System Price Over 3 Years 1,703,613 TPC-H Price/Performance Metric ($/QphH@1000GB) Measurement Intervals Measurement Interval in Throughput Test (Ts) 35,901 Duration of Stream Execution: Query Start Time RF1 Start Time RF2 Start Time Power Run Seed Query End Time 04/13/10 11:01:10 04/13/10 11:17:49 Duration (sec) 999 RF1 End Time 04/13/10 11:00:30 04/13/10 11:01:10 RF2 End Time 04/13/10 11:17:50 04/13/10 11:18:46 Throuput Stream Seed Query Start Time Query End Time 04/13/10 19:31:51 04/13/10 18:37:33 04/13/10 19:46:27 04/13/10 18:10:03 04/13/10 20:03:03 04/13/10 15:57:48 04/13/10 17:59:52 04/13/10 16:49:36 04/13/10 17:06:01 04/13/10 17:21:11 Duration (sec) 29,584 26,326 30,460 24,676 31,456 16,741 24,065 19,849 20,834 21,743 RF1 Start Time RF1 End Time 04/13/10 20:10:03 04/13/10 20:10:39 04/13/10 20:11:14 04/13/10 20:11:46 04/13/10 20:12:21 04/13/10 20:12:59 04/13/10 20:13:34 04/13/10 20:13:57 04/13/10 20:14:32 04/13/10 20:14:55 04/13/10 20:15:30 04/13/10 20:15:53 04/13/10 20:16:28 04/13/10 20:16:51 04/13/10 20:17:26 04/13/10 20:17:50 04/13/10 20:18:25 04/13/10 20:18:48 04/13/10 20:19:23 04/13/10 20:19:46 RF2 Start Time RF2 End Time 04/13/10 20:10:39 04/13/10 20:11:14 04/13/10 20:11:46 04/13/10 20:12:21 04/13/10 20:12:59 04/13/10 20:13:34 04/13/10 20:13:57 04/13/10 20:14:32 04/13/10 20:14:55 04/13/10 20:15:30 04/13/10 20:15:53 04/13/10 20:16:28 04/13/10 20:16:51 04/13/10 20:17:26 04/13/10 20:17:50 04/13/10 20:18:25 04/13/10 20:18:48 04/13/10 20:19:23 04/13/10 20:19:46 04/13/10 20:20:21

4 Duration of Stream Execution (Continued): Throuput Stream Seed Query Start Time Query End Time 04/13/10 16:27:34 04/13/10 16:30:56 04/13/10 19:25:03 04/13/10 18:48:08 04/13/10 17:28:19 04/13/10 18:41:15 04/13/10 19:29:44 04/13/10 18:18:48 04/13/10 19:45:56 04/13/10 16:56:38 04/13/10 20:02:15 04/13/10 18:19:51 04/13/10 18:24:04 04/13/10 18:14:02 04/13/10 17:49:44 04/13/10 18:40:42 04/13/10 18:21:52 04/13/10 18:28:53 04/13/10 16:57:06 04/13/10 20:10:03 Duration (sec) 18,526 18,728 29,175 26,960 22,171 26,547 29,456 25,200 30,428 20,269 31,407 25,263 25,515 24,914 23,455 26,513 25,383 25,804 20,297 31,874 RF1 Start Time RF1 End Time 04/13/10 20:20:21 04/13/10 20:20:46 04/13/10 20:21:21 04/13/10 20:21:48 04/13/10 20:22:23 04/13/10 20:22:47 04/13/10 20:23:22 04/13/10 20:23:54 04/13/10 20:24:29 04/13/10 20:24:56 04/13/10 20:25:30 04/13/10 20:26:03 04/13/10 20:26:37 04/13/10 20:27:07 04/13/10 20:27:41 04/13/10 20:28:06 04/13/10 20:28:41 04/13/10 20:29:10 04/13/10 20:29:44 04/13/10 20:30:15 04/13/10 20:30:51 04/13/10 20:31:16 04/13/10 20:31:50 04/13/10 20:32:22 04/13/10 20:32:56 04/13/10 20:33:27 04/13/10 20:34:02 04/13/10 20:34:33 04/13/10 20:35:07 04/13/10 20:35:38 04/13/10 20:36:12 04/13/10 20:36:42 04/13/10 20:37:17 04/13/10 20:37:48 04/13/10 20:38:23 04/13/10 20:38:54 04/13/10 20:39:29 04/13/10 20:39:58 04/13/10 20:40:33 04/13/10 20:40:58 RF2 Start Time RF2 End Time 04/13/10 20:20:46 04/13/10 20:21:21 04/13/10 20:21:48 04/13/10 20:22:23 04/13/10 20:22:47 04/13/10 20:23:22 04/13/10 20:23:54 04/13/10 20:24:29 04/13/10 20:24:56 04/13/10 20:25:30 04/13/10 20:26:03 04/13/10 20:26:37 04/13/10 20:27:07 04/13/10 20:27:41 04/13/10 20:28:06 04/13/10 20:28:41 04/13/10 20:29:10 04/13/10 20:29:44 04/13/10 20:30:15 04/13/10 20:30:51 04/13/10 20:31:16 04/13/10 20:31:50 04/13/10 20:32:22 04/13/10 20:32:56 04/13/10 20:33:27 04/13/10 20:34:02 04/13/10 20:34:33 04/13/10 20:35:07 04/13/10 20:35:38 04/13/10 20:36:12 04/13/10 20:36:42 04/13/10 20:37:17 04/13/10 20:37:48 04/13/10 20:38:23 04/13/10 20:38:54 04/13/10 20:39:29 04/13/10 20:39:58 04/13/10 20:40:33 04/13/10 20:40:58 04/13/10 20:41:33

5 Duration of Stream Execution (Continued): Throuput Stream Seed Query Start Time Query End Time 04/13/10 17:57:35 04/13/10 18:43:05 04/13/10 19:36:37 04/13/10 17:41:45 04/13/10 18:12:13 04/13/10 18:45:23 04/13/10 19:51:24 04/13/10 17:49:35 04/13/10 18:19:11 04/13/10 18:16:45 04/13/10 17:56:35 04/13/10 19:15:46 04/13/10 17:29:11 04/13/10 11:18:53 04/13/10 17:26:31 04/13/10 11:18:53 04/13/10 18:15:28 04/13/10 11:18:53 04/13/10 20:05:40 04/13/10 17:13:03 04/13/10 19:21:10 04/13/10 19:24:40 04/13/10 17:37:28 Duration (sec) 23,926 26,656 29,868 22,976 24,803 26,793 30,754 23,445 25,221 25,074 23,864 28,616 22,221 22,058 24,995 31,607 21,252 28,939 29,149 22,717 RF1 Start Time RF1 End Time 04/13/10 20:41:33 04/13/10 20:42:01 04/13/10 20:42:35 04/13/10 20:43:05 04/13/10 20:43:44 04/13/10 20:44:14 04/13/10 20:44:48 04/13/10 20:45:18 04/13/10 20:45:52 04/13/10 20:46:17 04/13/10 20:46:51 04/13/10 20:47:19 04/13/10 20:47:53 04/13/10 20:48:23 04/13/10 20:48:57 04/13/10 20:49:24 04/13/10 20:49:59 04/13/10 20:50:31 04/13/10 20:51:05 04/13/10 20:51:36 04/13/10 20:52:10 04/13/10 20:52:36 04/13/10 20:53:11 04/13/10 20:53:38 04/13/10 20:54:12 04/13/10 20:54:43 04/13/10 20:55:17 04/13/10 20:55:49 04/13/10 20:56:23 04/13/10 20:56:53 04/13/10 20:57:28 04/13/10 20:57:54 04/13/10 20:58:28 04/13/10 20:58:55 04/13/10 20:59:30 04/13/10 21:00:02 04/13/10 21:00:36 04/13/10 21:01:02 04/13/10 21:01:37 04/13/10 21:02:02 RF2 Start Time RF2 End Time 04/13/10 20:42:01 04/13/10 20:42:35 04/13/10 20:43:05 04/13/10 20:43:44 04/13/10 20:44:14 04/13/10 20:44:48 04/13/10 20:45:18 04/13/10 20:45:52 04/13/10 20:46:17 04/13/10 20:46:51 04/13/10 20:47:19 04/13/10 20:47:53 04/13/10 20:48:23 04/13/10 20:48:57 04/13/10 20:49:24 04/13/10 20:49:59 04/13/10 20:50:31 04/13/10 20:51:05 04/13/10 20:51:36 04/13/10 20:52:10 04/13/10 20:52:36 04/13/10 20:53:10 04/13/10 20:53:38 04/13/10 20:54:12 04/13/10 20:54:43 04/13/10 20:55:17 04/13/10 20:55:49 04/13/10 20:56:23 04/13/10 20:56:53 04/13/10 20:57:28 04/13/10 20:57:54 04/13/10 20:58:28 04/13/10 20:58:55 04/13/10 20:59:30 04/13/10 21:00:02 04/13/10 21:00:36 04/13/10 21:01:02 04/13/10 21:01:37 04/13/10 21:02:02 04/13/10 21:02:37

6 Duration of Stream Execution (Continued): Throuput Query Start Time Seed Stream Query End Time /13/10 18:34: /13/10 18:50: /13/10 18:39: /13/10 19:48: /13/10 17:42: /13/10 17:02: /13/10 16:34: /13/10 19:13: /13/10 18:36: /13/10 11:18:53 04/13/10 17:51: /13/10 17:41: /13/10 20:08: /13/10 18:34: /13/10 19:22:43 Duration (sec) 26,137 27,091 26,444 30,598 22,989 20,625 18,959 28,461 26,283 23,583 22,951 31,775 26,154 29,031 RF1 Start Time RF1 End Time 04/13/10 21:02:37 04/13/10 21:03:05 04/13/10 21:03:39 04/13/10 21:04:04 04/13/10 21:04:38 04/13/10 21:05:02 04/13/10 21:05:36 04/13/10 21:06:04 04/13/10 21:06:38 04/13/10 21:07:02 04/13/10 21:07:36 04/13/10 21:08:05 04/13/10 21:08:40 04/13/10 21:09:11 04/13/10 21:09:45 04/13/10 21:10:13 04/13/10 21:10:48 04/13/10 21:11:16 04/13/10 21:11:51 04/13/10 21:12:22 04/13/10 21:12:57 04/13/10 21:13:20 04/13/10 21:13:55 04/13/10 21:14:24 04/13/10 21:14:59 04/13/10 21:15:32 04/13/10 21:16:06 04/13/10 21:16:33 RF2 Start Time RF2 End Time 04/13/10 21:03:05 04/13/10 21:03:39 04/13/10 21:04:04 04/13/10 21:04:38 04/13/10 21:05:02 04/13/10 21:05:36 04/13/10 21:06:04 04/13/10 21:06:38 04/13/10 21:07:02 04/13/10 21:07:36 04/13/10 21:08:05 04/13/10 21:08:40 04/13/10 21:09:11 04/13/10 21:09:45 04/13/10 21:10:13 04/13/10 21:10:48 04/13/10 21:11:16 04/13/10 21:11:51 04/13/10 21:12:22 04/13/10 21:12:57 04/13/10 21:13:20 04/13/10 21:13:55 04/13/10 21:14:24 04/13/10 21:14:59 04/13/10 21:15:32 04/13/10 21:16:06 04/13/10 21:16:33 04/13/10 21:17:07

7 TPC-H Timing Intervals (in seconds) Duration of stream execution: Stream ID Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 Q12 Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream

8 TPC-H Timing Intervals (in seconds) Duration of stream execution: Stream ID Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 Q12 Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Minimum Maximum Average

9 TPC-H Timing Intervals (in seconds) Duration of stream execution: Stream ID Q13 Q14 Q15a Q16 Q17 Q18 Q19 Q20 Q21 Q22 RF1 RF2 Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream

10 TPC-H Timing Intervals (in seconds) Duration of stream execution: Stream ID Q13 Q14 Q15a Q16 Q17 Q18 Q19 Q20 Q21 Q22 RF1 RF2 Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Stream Minimum Average Maximum

P500/700/900 Part Number. P510/710/910 Part Number N/A N/A SBB0K65455 N/A N/A N/A SBB0K65456 N/A N/A N/A SBB0K65457 N/A N/A N/A SBB0K65521 N/A

P500/700/900 Part Number. P510/710/910 Part Number N/A N/A SBB0K65455 N/A N/A N/A SBB0K65456 N/A N/A N/A SBB0K65457 N/A N/A N/A SBB0K65521 N/A PDF Version: 2.0, April 6, 2016 MAINSTREAM SYSTEMS SBB P410 Part Number P500/700/900 Part Number P510/710/910 Part Number Option Part Number P410 P500 P510 Processors Xeon E5 2600 s Broadwell Intel Xeon

More information

Now every device for small & medium businesses, at zero upfront

Now every device for small & medium businesses, at zero upfront Now every device for small & medium businesses, at zero upfront Well, almost every device etisalat.ae/businessdevices 6180_Device2 Rate Card_Combined Generic/24 September 2017 Business Devices Rate Card

More information

DataCore Cloud Service Provider Program (DCSPP) Product Guide

DataCore Cloud Service Provider Program (DCSPP) Product Guide DataCore Cloud Service Provider Program (DCSPP) Product Guide Effective: March 1, 2017 Table of Contents Overview... 1 Licensing and Pricing... 1 Choice of DCSPP Monthly Point Plans... 2 DCSPP Product

More information

BID DESCRIPTION : SUPPLY AND DELIVERY OF A STORAGE ALLOCATED NETWORK (SAN) UNIT

BID DESCRIPTION : SUPPLY AND DELIVERY OF A STORAGE ALLOCATED NETWORK (SAN) UNIT THE BIDDER TENDER NO. : IRBA002/2018/RFT CLOSING DATE : 04 APRIL 2018 AT 12H00 VALIDITY PERIOD : 90 DAYS (CALCULATED FROM CLOSING DATE) BID DESCRIPTION : SUPPLY AND DELIVERY OF A STORAGE ALLOCATED NETWORK

More information

Persistent Memory Performance Benchmarking & Comparison. Eden Kim, Calypso Systems, Inc. John Kim, Mellanox Technologies, Inc.

Persistent Memory Performance Benchmarking & Comparison. Eden Kim, Calypso Systems, Inc. John Kim, Mellanox Technologies, Inc. Persistent Memory Performance Benchmarking & Comparison Eden Kim, Calypso Systems, Inc. John Kim, Mellanox Technologies, Inc. PM Benchmarking & Comparison Part 1: Test Plan & Workloads Eden Kim of Calypso

More information

AccuRAID iscsi Auto-Tiering Best Practice

AccuRAID iscsi Auto-Tiering Best Practice AccuRAID iscsi Auto-Tiering Best Practice Overview From the perspective of storage features, the performance of SSDs are high, but the cost is also high per GB. Relatively speaking, the cost of a traditional

More information

Airflow Options for Cisco MDS 9396S SAN Switch

Airflow Options for Cisco MDS 9396S SAN Switch Airflow Options for Cisco MDS 9396S SAN Switch This document describes how to configure, administer and troubleshoot airflow options in the MDS 9396S switch. Anyone can use this document along with hardware

More information

REPORT, RE0813, MIL, ENV, 810G, TEMP, IN HOUSE, , PASS

REPORT, RE0813, MIL, ENV, 810G, TEMP, IN HOUSE, , PASS REPORT, RE0813, MIL, ENV, 810G, TEMP, IN HOUSE, TST 00191 REV. A Crystal Group Inc 850 Kacena Rd., Hiawatha, IA Phone: 877 279 7863 Fax: 319 393 2338 9/23/2014 Revision History REV Date Approved Description

More information

Better data means better CPR.

Better data means better CPR. PRODUCT BROCHURE Better data means better CPR. CODE-STAT DATA REVIEW SOFTWARE For Hospitals CODE-STAT software gives you the data you need to improve CPR quality. CPR can always get better. CODE-STAT data

More information

General Notes: NOTE: NOTE:

General Notes: NOTE: NOTE: Symantec Storage Foundation and High Availability Solutions 6.1, 6.1.1, 6.2, 6.2.1 (AIX, Linux, Solaris), and Dynamic Multi-Pathing for VMware 6.1, 6.2 Hardware Compatibility List Copyright 2016 Veritas

More information

SQL LiteSpeed 3.0 Installation Guide

SQL LiteSpeed 3.0 Installation Guide SQL LiteSpeed 3.0 Installation Guide Revised January 27, 2004 Written by: Jeremy Kadlec Edgewood Solutions www.edgewoodsolutions.com 888.788.2444 2 Introduction This guide outlines the SQL LiteSpeed 3.0

More information

POLICY GUIDE. DataCore Cloud Service Provider Program (DCSPP) DCSPP OVERVIEW POLICY GUIDE INTRODUCTION PROGRAM MEMBERSHIP DCSPP AGGREGATORS

POLICY GUIDE. DataCore Cloud Service Provider Program (DCSPP) DCSPP OVERVIEW POLICY GUIDE INTRODUCTION PROGRAM MEMBERSHIP DCSPP AGGREGATORS DataCore Cloud Service Provider Program (DCSPP) Effective: March 1, 2019 INTRODUCTION Welcome to the DataCore Cloud Service Provider Program (the DCSPP ) Policy Guide for authorized Cloud Service Providers

More information

DDR Dive Data Recorder Manual - Rel /12

DDR Dive Data Recorder Manual - Rel /12 DDR Dive Data Recorder Manual - Rel. 1.1 2/12 TABLE OF CONTENTS 1. WHAT IS THE DDR? 4 2. TECHNICAL CHARACTERISTICS 5 3. DOWNLOADING DATA TO A PC 6 4. DDR MANAGER 7 5. CONFIGURE DEVICE BUTTON 9 6. READ

More information

SHIMADZU LC-10/20 PUMP

SHIMADZU LC-10/20 PUMP SHIMADZU LC-10/20 PUMP Clarity Control Module ENG Code/Rev.: M091/70C Date: 24.10.2017 Phone: +420 251 013 400 DataApex Ltd. Fax: +420 251 013 401 Petrzilkova 2583/13 clarity@dataapex.com 158 00 Prague

More information

STAND alone & p.c. VERSION

STAND alone & p.c. VERSION STAND alone & p.c. VERSION ECONOMY TRACK SYSTEMS 1/4 & 1/8 Mile Asphalt Track Dirt / Sand Track Mud Track Snowmobile Track R/C Car Track Custom Track Systems Timing to.001 Accuracy Time Slip Printer Optional

More information

Introduction. The HCL also contains information for Dynamic Multi-Pathing for VMware 6.1, 6.2, and Veritas Access 7.1, 7.2.

Introduction. The HCL also contains information for Dynamic Multi-Pathing for VMware 6.1, 6.2, and Veritas Access 7.1, 7.2. Symantec Storage Foundation and High Availability Solutions 6.1, 6.1.1, 6.2, 6.2.1, Dynamic Multi-Pathing for VMware 6.1, 6.2, and Veritas Access 7.1, 7.2 Hardware Compatibility List Copyright 2017 Veritas

More information

Hardware Compatibility List

Hardware Compatibility List Symantec Storage Foundation and High Availability Solutions 6.0, 6.0 Platform Release 1 (Solaris), 6.0.1, 6.0.2 (Linux), 6.0.3, 6.0.4 (Linux), 6.0.5 and Dynamic Multi-Pathing for VMware 6.0, 6.0.1 Hardware

More information

AGW SYSTEMS. Blue Clock W38X

AGW SYSTEMS. Blue Clock W38X AGW SYSTEMS Blue Clock W38X Contents table BLUECLOCKS...3 THE EVOLUTION...4 WHAT S NEW!...5 HARDWARE...6 SOFTWARE...7 MULTI COMPANY...8 INSTANTLY...9 EVEN MORE!...10 WHAT S INSIDE HOW DOES IT WORK...11...12

More information

AN-140. Protege WX SALLIS Integration Application Note

AN-140. Protege WX SALLIS Integration Application Note AN-140 Protege WX SALLIS Integration Application Note The specifications and descriptions of products and services contained in this document were correct at the time of printing. Integrated Control Technology

More information

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS WARNING THE WARRANTIES MADE BY MSA WITH RESPECT TO THE PRODUCT ARE VOIDED IF THE PRODUCT IS NOT USED AND MAINTAINED IN ACCORDANCE

More information

Excel 2013 Pivot Table Calculated Field Greyed Out

Excel 2013 Pivot Table Calculated Field Greyed Out Excel 2013 Pivot Table Calculated Field Greyed Out Use Excel pivot table calculated item to create unique items in a pivot table field. (00:47 minute mark) Group By Date: Excel PivotTable: 1) Drag Date

More information

We release Mascot Server 2.6 at the end of last year. There have been a number of changes and improvements in the search engine and reports.

We release Mascot Server 2.6 at the end of last year. There have been a number of changes and improvements in the search engine and reports. 1 We release Mascot Server 2.6 at the end of last year. There have been a number of changes and improvements in the search engine and reports. I ll also be covering some enhancements and changes in Mascot

More information

Volume A Question No : 1 You can monitor your Steelhead appliance disk performance using which reports? (Select 2)

Volume A Question No : 1 You can monitor your Steelhead appliance disk performance using which reports? (Select 2) Volume A~D: 342 Questions Volume A Question No : 1 You can monitor your Steelhead appliance disk performance using which reports? (Select 2) A. Data Store Cost B. Data Store Performance C. Disk Load D.

More information

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com Operating Manual Software for Fire and Gas Warning Units Order No.: 10154656/01 MSAsafety.com MSA Europe GmbH Schlüsselstrasse 12 8645 Rapperswil-Jona Switzerland info.ch@msasafety.com www.msasafety.com

More information

Typical Wayside Reader System Quotation

Typical Wayside Reader System Quotation Typical Wayside Reader System Quotation Please note that components can be added or deleted to the quotation to meet the customer s individual requirements. This is in response to your request for a quotation

More information

Veritas InfoScale Foundation, Availability, Storage and Enterprise Solutions 7.3, (AIX, Linux, Solaris) Hardware Compatibility List

Veritas InfoScale Foundation, Availability, Storage and Enterprise Solutions 7.3, (AIX, Linux, Solaris) Hardware Compatibility List Veritas InfoScale Foundation, Availability, Storage and Enterprise Solutions 7.3, 7.3.1 (AIX, Linux, Solaris) Hardware Compatibility List Copyright 2017 Veritas Technologies LLC. All rights reserved. Veritas

More information

Hardware Compatibility List

Hardware Compatibility List Symantec Storage Foundation and High Availability Solutions 5.1 (AIX, Linux, Solaris), 5.1 SP1, 5.1 SP1 RP3 (AIX, HP-UX, Linux, Solaris), 5.1 SP1 RP4 (AIX, Linux, Solaris), 5.1 PR1 (Linux), 5.1 SP1 PR4

More information

Connect with Confidence NO POWER NO PROBLEM

Connect with Confidence NO POWER NO PROBLEM Connect with Confidence NO POWER NO PROBLEM The ideal solution to implement wireless sensor monitoring in IoT applications where power is not available. At last, there s a roll-out ready way to implement

More information

ONSIGHT FIREWALL CONFIGURATION GUIDE

ONSIGHT FIREWALL CONFIGURATION GUIDE ONSIGHT FIREWALL CONFIGURATION GUIDE Librestream Onsight Firewall Configuration Guide Doc #: 400295-00, rev A March 2017 Information in this document is subject to change without notice. Reproduction in

More information

Now every device for small & medium businesses, at zero upfront

Now every device for small & medium businesses, at zero upfront Now every device for small & medium businesses, at zero upfront Well, almost every device etisalat.ae/businessdevices 6180_Device2 Rate Card_Combined Generic/30 July 2017 Business Devices Rate Card Go

More information

Veritas InfoScale Foundation, Availability, Storage and Enterprise Solutions 7.3, and 7.4 (AIX, Linux, Solaris) Hardware Compatibility List

Veritas InfoScale Foundation, Availability, Storage and Enterprise Solutions 7.3, and 7.4 (AIX, Linux, Solaris) Hardware Compatibility List Veritas InfoScale Foundation, Availability, Storage and Enterprise Solutions 7.3, 7.3.1 and 7.4 (AIX, Linux, Solaris) Hardware Compatibility List Copyright 2018 Veritas Technologies LLC. All rights reserved.

More information

Mac Software Manual for FITstep Pro Version 2

Mac Software Manual for FITstep Pro Version 2 Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund

More information

HCP Support Matrix Hitachi VSP G1x00, F1500, Gx00, Fxx0, VSP, and HUS VM, AMS 2500

HCP Support Matrix Hitachi VSP G1x00, F1500, Gx00, Fxx0, VSP, and HUS VM, AMS 2500 HCP Support Matrix Hitachi VSP G1x00, F1500, Gx00, Fxx0, VSP, and HUS VM, AMS 2500 Introduction Use this interoperability matrix to check whether a proposed customer configuration is supported. Each tab

More information

Electronic Oncology Systems the Management and the Safety Measures. Hansen Chen, Director, TDSI

Electronic Oncology Systems the Management and the Safety Measures. Hansen Chen, Director, TDSI Electronic Oncology Systems the Management and the Safety Measures Hansen Chen, Director, TDSI Radiation Oncology Department People Place Equipments Procedures Patients Hansen Chen 2 Radiation Oncology

More information

About us. Try us to trace your network!

About us. Try us to trace your network! About us Company KOMPLEX was founded in 1994 by Mr. Stefan Sivak in Zilina, Slovakia. KOMPLEX focuses on development and production of Radio Frequency Identification Systems assigned for underground networks.

More information

MotoTally. Enduro Event Management and Reporting Application

MotoTally. Enduro Event Management and Reporting Application MotoTally Enduro Event Management and Reporting Application The Problem The management of enduro events (signup, scoring, posting results) is either done manually, or involves a combination of manual effort

More information

Delta Compressed and Deduplicated Storage Using Stream-Informed Locality

Delta Compressed and Deduplicated Storage Using Stream-Informed Locality Delta Compressed and Deduplicated Storage Using Stream-Informed Locality Philip Shilane, Grant Wallace, Mark Huang, & Windsor Hsu Backup Recovery Systems Division EMC Corporation Motivation and Approach

More information

Distributed Power Management: Technical Deep Dive + Real World Example

Distributed Power Management: Technical Deep Dive + Real World Example Distributed Power Management: Technical Deep Dive + Real World Example Breakout Session # TA2197 Anne Holler Anthony Vecchiolla VMware Engineering International Integrated Solutions Date: September 18,

More information

SteelHead Product Family

SteelHead Product Family Specification Sheet 05.08.18 SteelHead Product Family SteelHead CX Branch Office SteelHead Mid-Size Office SteelHead CX255 Series CX570 Series CX770 Series Configurations U L M H L M H L M H Profile Desktop

More information

The API states the following about tube rupture for a shell-and-tube heat exchangers:

The API states the following about tube rupture for a shell-and-tube heat exchangers: Tutorial This tutorial describes the theory and modeling process of a tube rupture event using the special element type Rupture element in BOSfluids. It covers the algorithm BOSfluids uses to model the

More information

Product Overview. Product Description CHAPTER

Product Overview. Product Description CHAPTER CHAPTER 1 This chapter provides a functional overview of the Cisco Redundant Power System 2300 and covers these topics: Product Description, page 1-1 Features, page 1-3 Supported Devices, page 1-4 Deployment

More information

Lenovo ThinkAgile SX for Microsoft Azure Stack Planning and Setup Guide

Lenovo ThinkAgile SX for Microsoft Azure Stack Planning and Setup Guide Lenovo ThinkAgile SX for Microsoft Azure Stack Planning and Setup Guide Models: SXM4200, SXM6200, SXM4400, SXM6400 Note Before using this information and the product it supports, be sure to read and understand

More information

VROC (Viscometer/ Rheometer-on-a-Chip) User s Manual 1

VROC (Viscometer/ Rheometer-on-a-Chip) User s Manual 1 VROC (Viscometer/ Rheometer-on-a-Chip) User s Manual 1 2 Table of Contents 1. Unpacking 4 2. Precautions 6 3. Hardware Setup 7 4. Sample Loading 8 5. Loading the Syringe on the Pump 9 6. Chip to the Syringe

More information

General Notes: NOTE: NOTE: NOTE:

General Notes: NOTE: NOTE: NOTE: Veritas InfoScale Foundation, Availability, Storage and Enterprise Solutions 7.1 (AIX, Linux, Solaris), and DMP for VMware 7.1 Hardware Compatibility List Copyright 2018 Veritas Technologies LLC. All rights

More information

exsm.cluster High Availability for TSM Server Michael Abel & Bruno Friess TSM Symposium Oxford September 2005 Hier Kundenlogo

exsm.cluster High Availability for TSM Server Michael Abel & Bruno Friess TSM Symposium Oxford September 2005 Hier Kundenlogo Hier Kundenlogo TSM Symposium -Logo vor weißem Hintergrund, dann Größe anpassen und Oxford Text löschen - Logo transparent (GIF), dann Block löschen - ohne Logo: Text+Block löschen September 2005 exsm.cluster

More information

CS 341 Computer Architecture and Organization. Lecturer: Bob Wilson Cell Phone: or

CS 341 Computer Architecture and Organization. Lecturer: Bob Wilson Cell Phone: or CS 341 Computer Architecture and Organization Lecturer: Bob Wilson Cell Phone: 508-577-9895 Email: robert.wilson@umb.edu or bobw@cs.umb.edu 1 Welcome to CS341 This course teaches computer architecture

More information

Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software

Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software For technical support, call your local Bio-Rad office, or in the US, call 1-800-424-6723. Bio-Rad Laboratories, Inc.,

More information

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services Diver-Office Getting Started Guide 2007, Schlumberger Water Services Copyright Information 2007 Schlumberger Water Services. All rights reserved. No portion of the contents of this publication may be reproduced

More information

KEM Scientific, Inc. Instruments for Science from Scientists

KEM Scientific, Inc. Instruments for Science from Scientists KEM Scientific, Inc. Instruments for Science from Scientists J-KEM Scientific, Inc. 6970 Olive Blvd. St. Louis, MO 63130 (314) 863-5536 Fax (314) 863-6070 E-Mail: jkem911@jkem.com Precision Vacuum Controller,

More information

High Performance Electronic Components 1411 S. Roselle Rd Schaumburg, IL Fax

High Performance Electronic Components 1411 S. Roselle Rd Schaumburg, IL Fax Air Quality Computer U.S. PATENT #5,509,295 Invented and Manufactured By High Performance Electronic Components 1411 S. Roselle Rd Schaumburg, IL 60193 847-923-0002 Fax 847-923-0004 www.altronicsinc.com

More information

TA Instruments Installation Requirements for the Thermal Discovery Series

TA Instruments Installation Requirements for the Thermal Discovery Series Notice TA Instruments Installation Requirements for the Thermal Discovery Series Thank you for ordering a Discovery Series thermal analysis system from TA Instruments. To ensure that installation of your

More information

Instruction Manual. BZ7002 Calibration Software BE

Instruction Manual. BZ7002 Calibration Software BE Instruction Manual BZ7002 Calibration Software BE6034-12 Index _ Index Index... 2 Chapter 1 BZ7002 Calibration Software... 4 1. Introduction... 5 Chapter 2 Installation of the BZ7002... 6 2. Installation

More information

General Specifications

General Specifications General Specifications Gas Flow Calculation Portfolio GS 34P02P31-01E GENERAL This general specification document describes the Gas Flow Calculation Portfolio on FCN/FCJ autonomous controllers. Using this

More information

Sales Quotation For: Tyler Software & Related Services. City of Cape Girardeau Page 1 of 9

Sales Quotation For: Tyler Software & Related Services. City of Cape Girardeau Page 1 of 9 Quoted By: David Regnery Date: 08/30/2012 Quote Expiration: 10/31/2012 Quote Name: City of Cape Girardeau Quote Number: 38370 Sales Quotation For: Mr. John Richbourg City of Cape Girardeau 401 Independence

More information

SA Compatibility List

SA Compatibility List SA Compatibility List Passive Recommended Best Fit Active Recommended Best Fit MFG Model Desc RU Depth Switch Intake Switch Exhaust ACS 48 Cyclade server 1 side side SA1 01001NB SA2 003 Alcatel 6850 Omniswitch

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

Discovery HP-TGA 75/750. Site Preparation Guide

Discovery HP-TGA 75/750. Site Preparation Guide Discovery HP-TGA 75/750 Site Preparation Guide Revision A Issued August 2018 Table of Contents Table of Contents... 2 Ideal Setup... 3 System Components... 4 Instrument Measurements... 5 Utility Requirements...

More information

Wickets Administrator

Wickets Administrator Wickets Administrator Software For Managing Stored Value Wickets 01/08/2008 Product Details And Operating Instructions Overview This page describes each major function of Wickets Administrator in detail.

More information

APC SMART UPS 750VAUSB &

APC SMART UPS 750VAUSB & CLIN Make Sale_Area Product Type Description Model_No _Unit Annual APC SMART UPS 750VAUSB & S15387050ATBBAPC000001CONUS APC CONUS Telephone Cable SERIAL RM 1U 120V SUA750RM1U EACH $0.00 N/A $0.00 $722.47

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale

More information

Code Basic module and level control complete with optionals code

Code Basic module and level control complete with optionals code AUTOMATION AND PROCESS CONTROL MPCT - Modular Process Control Trainer Code 916960 Basic module and level control complete with optionals code 916961-916962-916963-916964-916965 1. General Didacta proposes

More information

CLUB REGISTRATION & SUPPORT / TICKETING

CLUB REGISTRATION & SUPPORT / TICKETING CLUB REGISTRATION & SUPPORT / TICKETING Version number: 1.0 Account Manager: Kevin Fowler Nemisys Authors: Andy Felton & Paul Keeling Nemisys English Golf Union Customer Name: Club Systems International

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Fibre Channel Option Card. User s Guide

Fibre Channel Option Card. User s Guide Fibre Channel Option Card User s Guide Fibre Channel Option Card User s Guide Note: Before using this information and the product it supports, read the information in Appendix F, Warranty information

More information

APP NOTES Onsight Connect Cisco Integration. July 2016

APP NOTES Onsight Connect Cisco Integration. July 2016 APP NOTES Onsight Connect Cisco Integration July 2016 Table of Contents 1. Direct Onsight Device to Cisco Endpoint Calling... 4 2. Onsight Device to Onsight Device (including Cisco Endpoint) Calling...

More information

Software Manual for FITstep Pro Version 2

Software Manual for FITstep Pro Version 2 Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund

More information

LT GasAnalyzer beyond standards

LT GasAnalyzer beyond standards beyond standards LT GASANALYZER Highly performant analyzer for measuring the concentration of technical gases based on a thermal conductivity sensor, an infrared sensor or a para-magnetic sensor. Combinations

More information

CLUSTERPRO. TEL CLUSTERPRO.

CLUSTERPRO.   TEL CLUSTERPRO. SSS Windows/ SSS for Windows UL1276-601 CD 3.1-10,000 - UL1276-604 Startup Kit 3.1-100,000 - UL1276-602 for Windows 3.1 for Windows 1CPU 300,000 3,800 UL1276-612 3.1 for Windows 2CPU 600,000 7,500 UL1276-622

More information

RM-80 respiration monitor

RM-80 respiration monitor RM-80 respiration monitor User Manual September 18, 2015 0025-003M 950 North Hague Avenue Columbus, Ohio 43204-2121 USA Sales: sales@colinst.com Service: service@colinst.com Phone: (614) 276-0861 Fax:

More information

Jackpot Rodeo - A Tutorial

Jackpot Rodeo - A Tutorial Jackpot Rodeo - A Tutorial The JRO software has a lot of options and variations, and can seem complicated to the first time user. Here is a fairly typical example of setting up and running a show that

More information

PRODUCT MANUAL. Diver-Mobile for Android

PRODUCT MANUAL. Diver-Mobile for Android PRODUCT MANUAL Diver-Mobile for Android Contact details: Van Essen Instruments B.V. Van Essen Instruments - Canada Delftechpark 20 630 Riverbend Drive, Suite 100 2628 XH Delft Kitchener, ON, The Netherlands

More information

[XACT INTEGRATION] The Race Director. Xact Integration

[XACT INTEGRATION] The Race Director. Xact Integration 2018 The Race Director Xact Integration [XACT INTEGRATION] This document describes the steps in using the direct integration that has been built between Race Director and Xact. There are three primary

More information

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6 LT GasAnalyzer LT GasAnalyzer Page 1 of 6 LT GasAnalyzer Disturbances in the protective gas supply can cause production losses or affect product quality. In the worst case, it even can endanger life and

More information

HyperSecureLink V6.0x User Guide

HyperSecureLink V6.0x User Guide HyperSecureLink V6.0x User Guide Note: This software works with the LS-30 Version (06.0x or later) 1, Hardware Installation: 1-1, Connection Diagram for USB or RS-232 Computer Interface To LS-30 CM1 To

More information

SR-242 USER S GUIDE. Table of Contents

SR-242 USER S GUIDE. Table of Contents User s Guide gfhf Table of Contents 1. Introduction...3 2. Faceplate...3 2.1 Parameter List...3 2.2 Parameter Buttons ( and )...4 2.3 Function Buttons ( and )...4 2.4 LED Status Window...4 2.5 Value Setting

More information

PitchTracker User Guide. Model: DKPT01 User Guide

PitchTracker User Guide. Model: DKPT01 User Guide PitchTracker User Guide Model: DKPT01 User Guide PACKAGE CONTENTS What Comes in the Box USING YOUR SMART BALL Turn On Your Smart Ball Pair your Smart Ball Turn Off Your Smart Ball Charge your Smart Ball

More information

uemis CONNECT: Synchronisation of the SDA with myuemis

uemis CONNECT: Synchronisation of the SDA with myuemis uemis CONNECT: Synchronisation of the SDA with myuemis 1 What is myuemis? In myuemis, your private area on the Internet portal www.uemis.com, you can visualise your dives, manage your database and transfer

More information

itexamdump 최고이자최신인 IT 인증시험덤프 일년무료업데이트서비스제공

itexamdump 최고이자최신인 IT 인증시험덤프   일년무료업데이트서비스제공 itexamdump 최고이자최신인 IT 인증시험덤프 http://www.itexamdump.com 일년무료업데이트서비스제공 Exam : 199-01 Title : Riverbed Certified Solutions Professional Vendor : Riverbed Version : DEMO 1 / 4 Get Latest & Valid 199-01 Exam's

More information

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer. NXT Main Menu My Files Files are automatically placed into the appropriate folders. When you download a program using a Sound file to the NXT, the program will be placed under Software files while the

More information

PRICED BID -PACKAGE II Page 1 of 19 Vendor Seal and Signature. Set 103. Set 23 pulse transmitter and Non return valve for 1.5" ethanol line.

PRICED BID -PACKAGE II Page 1 of 19 Vendor Seal and Signature. Set 103. Set 23 pulse transmitter and Non return valve for 1.5 ethanol line. 1 2 3 Supply of flowmeters 3" line: Supply of Positive displacement type flowmeters, Strainer with DPG, air eliminator, with pulse transmitter for 3" line Erection of Positive displacement type flowmeters,

More information

AR740 RPS Redundant Power Supply Quick Install Guide

AR740 RPS Redundant Power Supply Quick Install Guide AR740 RPS Redundant Power Supply Quick Install Guide AT-RPS 740 Quick Install Guide Document Number. 1999-2006 Allied Telesis Inc. All rights reserved. No part of this publication may be reproduced without

More information

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008 UNITY 2 TM Air Server Series 2 Operators Manual Version 1.0 February 2008 1. Introduction to the Air Server Accessory for UNITY 2...2 1.1. Summary of Operation...2 2. Developing a UNITY 2-Air Server method

More information

MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE

MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE HIGH-THROUGHPUT COMMUNICATIONS FOR MULTI-SERVICE NETWORKS MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE PTP 800 solutions can efficiently and affordably transport the data, voice and video that your bandwidth-intensive

More information

Modeling Signalized Traffic Intersections Using SAS Simulation Studio. Leow Soo Kar

Modeling Signalized Traffic Intersections Using SAS Simulation Studio. Leow Soo Kar Modeling Signalized Traffic Intersections Using SAS Simulation Studio Leow Soo Kar Department of Financial Mathematics and Statistics Sunway University 1 Contents Introduction. Case study. SAS Simulation

More information

PTP 800 SPLIT-MOUNT SOLUTION

PTP 800 SPLIT-MOUNT SOLUTION TM PTP 800 SPLIT-MOUNT SOLUTION LICENSED ETHERNET MICROWAVE FOR MULTI-SERVICE NETWORKS Cambium Point-to-Point (PTP) 800 Licensed Ethernet Microwave Solutions can efficiently and affordably transport the

More information

WildCat RF unit (0.5W), full 32-byte transmissions with built-in checksum

WildCat RF unit (0.5W), full 32-byte transmissions with built-in checksum Overview of SMRU series 9000 SRDL satellite tags Basic tag construction and function Housing: Standard sensors: Optional sensor: normal solid epoxy body rated to 500m, reinforced 2000m pressure (resolution

More information

AX5000 Operational Manual

AX5000 Operational Manual MIYACHI AMERICA CORPORATION The World Leader in Hermetic Sealing Systems AX5000 Operational Manual 0 Document #107-00092-001 Dec, 2013 AX5000 Operational Manual Miyachi America Corporation 1820 S. Myrtle

More information

Series Environmental Chambers

Series Environmental Chambers 3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable

More information

Smart Card based application for IITK Swimming Pool management

Smart Card based application for IITK Swimming Pool management CS499 End Semester Report Smart Card based application for IITK Swimming Pool management Submitted By: Ankur Mittal Project Guide: Prof. Rajat Moona Introduction In today s world, there is an increasing

More information

RPS900W Redundant Power Supply. Installation Guide.

RPS900W Redundant Power Supply. Installation Guide. RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A

More information

Cary 100/300/4000/ 5000/6000i Spectrometer. Site Preparation Guide

Cary 100/300/4000/ 5000/6000i Spectrometer. Site Preparation Guide Cary 100/300/4000/ 5000/6000i Spectrometer Site Preparation Guide Notices Agilent Technologies, Inc. 1996-2000, 2002, 2008, 2011-2012 No part of this manual may be reproduced in any form or by any means

More information

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11 ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11 The Portatree Eliminator Super 2000 Competition Track Timer can be used with an IBM Compatible Personal Computer connected through Com Port

More information

Instrument pucks. Copyright MBARI Michael Risi SIAM design review November 17, 2003

Instrument pucks. Copyright MBARI Michael Risi SIAM design review November 17, 2003 Instrument pucks Michael Risi SIAM design review November 17, 2003 Instrument pucks Pucks and Plug-and-Work The MBARI puck prototype Puck software interface Pucks in practice (A Puck s Tale) Embedding

More information

Stand-Alone Bubble Detection System

Stand-Alone Bubble Detection System Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When

More information

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules Digi Connect ME 9210 Linux: serial port 2 for JTAG modules Document History Date Version Change Description 08/05/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents...

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale

More information

955730_1 4/17/18. FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays

955730_1 4/17/18. FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays 955730_1 4/17/18 FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays Contents System Setup and Operation...3 Configuring Monitor for FlowSense...3 FlowSense Setup...4 Liquid Alerts...8 Monitoring

More information

General Specifications

General Specifications General Specifications GS 34P02P31-02E Gas Flow Calculation Portfolio (FCN-RTU) GENERAL This general specification document describes the Gas Flow Calculation Portfolio on FCN-RTU low power autonomous

More information

SA Compatibility List

SA Compatibility List SA Compatibility List Passive Recommended Best Fit Active Recommended Best Fit MFG Model Desc RU Depth Switch Intake Switch Exhaust ACS 48 Cyclade server 1 side side SA1 01001NB SA2 003 Alcatel 6850 Omniswitch

More information

ActiveYield. Operation and Adjustment

ActiveYield. Operation and Adjustment ActiveYield Operation and Adjustment 2018 System Requirements S-Series Combines Not compatible with S550 S650 - S660 and S760 combines with Manual Grain Tank Extensions Aftermarket Grain Tank Extensions

More information