PRICED BID -PACKAGE II Page 1 of 19 Vendor Seal and Signature. Set 103. Set 23 pulse transmitter and Non return valve for 1.5" ethanol line.
|
|
- Easter Harper
- 5 years ago
- Views:
Transcription
1 1 2 3 Supply of flowmeters 3" line: Supply of Positive displacement type flowmeters, Strainer with DPG, air eliminator, with pulse transmitter for 3" line Erection of Positive displacement type flowmeters, Strainer with DPG, air eliminator, with pulse transmitter for 3" line Testing & Commissioning of Positive displacement type flowmeters, Strainer with DPG, air eliminator, with pulse transmitter for 3" line Set 103 Set 103 Set 103 Supply of flowmeters 1.5" line: Supply of Positive displacement type flowmeters, 4 Strainer with DPG, air eliminator, with Set 23 pulse transmitter and Non return valve for 1.5" ethanol line 5 Erection of Positive displacement type flowmeters, Strainer with DPG, air eliminator, with pulse transmitter and Non return valve for 1.5" ethanol line Set Testing & commissioning of Positive displacement type flowmeters, Strainer with DPG, air eliminator, with pulse transmitter and Non return valve for 1.5" ethanol line Set Stop valve 3" for white oil:supply of Set Stop Valve 3"for white oil Set Erection of Set Stop Valve 3"for white oil Testing,Commissioning of Set Stop Valve 3"for white oil Set Stop valve 3" for black oil:supply of Set Stop Valve 3" for black oil 5 11 Erection of Set Stop Valve 3" for black oil PRICED BID -PACKAGE II Page 1 of 19 Vendor Seal and Signature
2 Testing,Commissioning of Set Stop Valve 12 3" for black oil Set Stop valve 1.5" for ethanol:supply of Set Stop Valve 1.5" for Ethanol Erection of Set Stop Valve 1.5" for Ethanol Testing,Commissioningof Set StopValve 1.5" for Ethanol Supply of Multi Channel Batch Controllers for White Oil with blending firmware & Two additive injection System Each 23 Each 23 Each 23 Each Erection of Multi channel Batch Controllers for White Oil with blending firmware & Two additive injection System Testing,Commissioning of Multi channel Batch Controllers for White Oil with blending firmware & Two additive injection System Supply of Multi channel Batch Controller for black oil Erection of Multi channel Batch Controller for black oil Testing,Commissioning of Multi channel Batch Controller for black oil Each 48 Each 48 Each 4 Each 4 Each 4 22 Supply of RTD at Each Loading Point Each Erection of above item Each Testing,Commissioning of above item Each 103 Supply of additive skid & other items 25 except block for MS Set 8 26 Erection of above item Set 8 27 Testing,Commissioning of above item Set 8 Supply of additive skid & other items 28 except block for HSD Set 8 29 Erection of above item Set 8 30 Testing,Commissioning of above item Set 8 PRICED BID -PACKAGE II Page 2 of 19 Vendor Seal and Signature
3 31 Supply of additive injection blocks Each Erection of above item Each Testing,Commissioning of above item Each 39 Supply of SS 304 pipeline for additive 34 System Meters Erection of above item Meters Testing,Commissioning of above item Meters Supply of 3" CS Plug Valve Each Erection of 3" CS Plug Valve Each Installation of 3" CS Plug Valve Each Supply of 1.5" CS Plug Valve Each Erection of 1.5" CS Plug Valve Each Installation of 1.5 " CS Plug Valve Each Supply of Loading arms Each Erection of Loading arms Each Testing,Commissioning of Loading arms Each 102 Supply of Earthing Relay and 2 Meters Long 16 sqmm cross-sectional area 46 braided copper Strip with heavy duty Each 52 clamps. Erection of Earthing Relay and 2 Meters Long 16 sqmm cross-sectional area 47 braided copper Strip with heavy duty Each 52 clamps. Testing,Commissioning of Earthing Relay and 2 Meters Long 16 sqmm crosssectional area braided copper Strip with 48 Each 52 heavy duty clamps. 49 Supply of mobile Proving tank (2 kl) Each 8 50 Erection of mobile Proving tank (2 kl) Each 8 51 Testing,CommissioningofmobileProving tank (2 kl) including W&M Stamping Each Supply of IS/ Explosion proof Proximity card readers Erection of IS/ Explosion proof Proximity card readers Each 84 Each 84 PRICED BID -PACKAGE II Page 3 of 19 Vendor Seal and Signature
4 54 Testing,Commissioning of IS/ Explosion proof Proximity card readers Each Supply of Proximity cards Each Supply of Remote Interaction Terminal Each Erection of Remote Interaction Terminal Each Testing,Commissioning of Remote Interaction Terminal Supply of Radar gauges for CRVT and fixed cum floating roof tank Erection of Radar gauges for CRVT and fixed cum floating roof tank Testing,Commissioning of Radar gauges for CRVT and fixed cum floating roof tank Average Temp. Sensor for CRVT:Supply of Average temperature sensor with water bottom sensor for CRVT and floating cum fixed roof Erection of Average temperature sensor with water bottom sensor for CRVT and floating cum fixed roof Testing,Commissioning of Average temperature sensor with water bottom sensor for CRVT and floating cum fixed roof Supply of Pressure transmitters for density measurement including Isolation valves Erection of Pressure transmitters for density measurement including Isolation valves Testing,Commissioning of Pressure transmitters for density measurement including Isolation valves Each Supply of Tank side Indicator 69 Erection of Tank side Indicator PRICED BID -PACKAGE II Page 4 of 19 Vendor Seal and Signature
5 Testing,Commissioning of Tank side 70 Indicator 71 Supply of radar gauges for FRVT Each Erection of radar gauges for FRVT Each 18 Testing,Commissioning of radar gauges 73 for FRVT Each Average Temp. Sensor for FRVT:Supply of Average temperature sensor with water bottom sensor for FRVT Erection of Average temperature sensor with water bottom sensor for FRVT Each 18 Each 18 Testing,Commissioning of Average 76 temperature sensor with water bottom sensor for FRVT Supply of Pressure transmitters for 77 density measurement including Isolation valves Erection of Pressure transmitters for 78 density measurement including Isolation valves Each 18 Each 18 Each Testing,Commissioning of Pressure transmitters for density measurement including Isolation valves Each Supply of Tank side Indicator Each Erection of Tank side Indicator Each 18 Testing,Commissioning of Tank side 82 Indicator Each 18 Supply of Computer Interface Unit in Hot 83 standby mode mounted in the Each 16 Networking panel. Erection of Computer Interface Unit in 84 Hot standby mode mounted in the Networking panel. Each Testing,Commissioning of Computer Interface Unit in Hot standby mode mounted in the Networking panel. Each 16 PRICED BID -PACKAGE II Page 5 of 19 Vendor Seal and Signature
6 Supply of radar gauges +/- 1mm for underground tanks, A/G horizontal A/G 86 tanks with local display along with Each 7 required still well pipe Erection of radar gauges +/- 1mm for underground tanks, A/G horizontal A/G 87 tanks with local display along with required still well pipe Each Testing,Commissioning of radar gauges +/- 1mm for underground tanks, A/G horizontal A/G tanks with local display along with required still well pipe Supply of radar gauges +/- 3mm for underground tanks, A/G horizontal A/G tanks with local display along with required still well pipe Erection of radar gauges +/- 3mm for underground tanks, A/G horizontal A/G tanks with local display along with required still well pipe Testing,Commissioning of radar gauges +/- 3 mm for underground tanks, A/G horizontal A/G tanks with local display along with required still well pipe Supply of Single point RTD with water bottom sensor in U/G tanks & AGHT Erection of Single point RTD with water bottom sensor in U/G tanks & AGHT Testing,Commissioning of Single point RTD with water bottom sensor in U/G tanks & AGHT Supply of density probe in U/G tanks & AGHT Erection of density probe in U/G tanks & AGHT Testing,Commissioning of density probe in U/G tanks & AGHT Each 7 Each 46 Each 31 Each 31 Each 38 Each 38 Each 38 Each 53 Each 38 Each 38 PRICED BID -PACKAGE II Page 6 of 19 Vendor Seal and Signature
7 Supply of float & Tape type Level 98 transmitters for Water tanks Each 14 Erection of float & Tape type Level 99 transmitters for Water tanks Each Testing,Commissioning of float & Tape type Level transmitters for Water tanks P.T.in header of white oil:supply of Pressure Transmitters in the header of White Oil Erection of Pressure Transmitters in the header of White Oil Testing,Commissioning of Pressure Transmitters in the header of White Oil Each 14 Each 31 Each 31 Each P.T in header of black oil:supply of Pressure Transmitters in the header of Each 4 black oil Erection of Pressure Transmitters in the header of black oil Each Testing,Commissioning of Pressure Transmitters in the header of black oil Supply of Densitometer in HSD header in Erection of Densitometer in HSD header in Testing,Commissioning of Densitometer in HSD header in Supply of Orifice plate in HSD header in Erection of Orifice plate in HSD header in Testing,Commissioning of Orifice Plate in HSD header in Supply of Densitometer SKO header in Erection of Densitometer SKO header in Each 4 Each 8 Each 8 PRICED BID -PACKAGE II Page 7 of 19 Vendor Seal and Signature
8 Testing,Commissioning of Densitometer SKO header in Supply of Orifice plate in SKO header in Erection of Orifice plate in SKO header in Testing,Commissioning of Orifice Plate in SKO header in Supply ofdensitometer onms header in Erection of densitometer on MS header in Testing,Commissioning of densitometer on MS header in Each 8 Each 8 Each 8 Each Supply of Orifice plate in MS header in Erection of Orifice plate in MS header in Testing,Commissioning of Orifice Plate in MS header in Densitometer for other product:supply of densitometer for other product as HEXANE/ FO/ LDO/BIODIESEL/ ATF/NAPTHA Erection of densitometer for other product as HEXANE/ FO/ LDO/BIODIESEL/ ATF/NAPTHA Testing,Commissioning of densitometer for other product as HEXANE/ FO/ LDO/BIODIESEL/ ATF/NAPTHA Orifice plate for other product:supply of Orifice Plate for other product as HEXANE/ FO/ LDO/BIODIESEL/ ATF/NAPTHA Erection of Orifice Plate for other product as HEXANE/ FO/ LDO/BIODIESEL/ ATF/NAPTHA Each 3 Each 3 Each 3 Each 3 Each 3 PRICED BID -PACKAGE II Page 8 of 19 Vendor Seal and Signature
9 Testing,Commissioning of Orifice Plate 130 for other product as HEXANE/ FO/ Each 3 LDO/BIODIESEL/ ATF/NAPTHA Densitometer for ethanol:supply of 131 Densitometer for ETHANOL Each Erection of Densitometer for ETHANOL Each 7 Testing,Commissioning of Densitometer 133 for ETHANOL Each 7 OrificePlatefor Ethanol:Supply oforifice 134 Plate for Ethanol Each Erection of Orifice Plate for Ethanol Each 7 Testing,Commissioning of Orifice Plate 136 for Ethanol Each 7 Supply of 12" line Bulk Air Eliminator with 137 Gate Valve, NRV & two Thermal Relief Each 2 Valve Erection of 12" line Bulk Air Eliminator 138 with Gate Valve, NRV & two Thermal Each 2 Relief Valve Testing,Commissioning of 12" line Bulk 139 Air Eliminator with Gate Valve, NRV & Each 2 two Thermal Relief Valve Supply of 10" line Bulk Air Eliminator with 140 Gate Valve, NRV & two Thermal Relief Each 2 Valve Erection of 10" line Bulk Air Eliminator & 141 Thermal Relief Valve Each 2 Testing,Commissioning of 10" line Bulk 142 Air Eliminator with Gate Valve, NRV & Each 2 two Thermal Relief Valve Supply of 8" line Bulk Air Eliminator with 143 Gate Valve, NRV & two Thermal Relief Each 7 Valve Erection of 8" line Bulk Air Eliminator 144 with Gate Valve, NRV & two Thermal Each 7 Relief Valve Testing,Commissioning of 8" line Bulk Air 145 Eliminator with Gate Valve, NRV & two Thermal Relief Valve Each 7 PRICED BID -PACKAGE II Page 9 of 19 Vendor Seal and Signature
10 Supply of 6" line Bulk Air Eliminator with 146 Gate Valve, NRV & two Thermal Relief Each 18 Valve Erection of 6" line Bulk Air Eliminator 147 with Gate Valve, NRV & two Thermal Each 18 Relief Valve Testing,Commissioning of 6" line Bulk Air 148 Eliminator with Gate Valve, NRV & two Each 18 Thermal Relief Valve Supply of 4" line Bulk Air Eliminator with 149 Gate Valve, NRV & two Thermal Relief Each 3 Valve Erection of 4" line Bulk Air Eliminator 150 with Gate Valve, NRV & two Thermal Each 3 Relief Valve Testing,Commissioning of 4" line Bulk 151 Air Eliminator with Gate Valve, NRV & Each 3 two Thermal Relief Valve Supply of 3" line Bulk Air Eliminator & 152 Thermal Relief Valve Each 3 Erection of 3" line Bulk Air Eliminator 153 with Gate Valve, NRV & two Thermal Each 3 Relief Valve Testing,Commissioning of 3" line Bulk Air 154 Eliminator with Gate Valve, NRV & two Each 3 Thermal Relief Valve Supply of pressure gauges with pulsation 155 dampener Each 124 Erection of pressure gauges with 156 pulsation dampener Each 124 Testing,Commissioning of pressure 157 gauges with pulsation dampener Each Supply of Electronic Display Unit Each Erection of Electronic Display Unit Each 8 Testing,Commissioning of Electronic 160 Display Unit Each 8 Supply of barrier gate with motor and IR 161 sensor Each 12 Erection of barrier gate with motor and IR 162 sensor Each 12 Testing,Commissioning of barrier gate 163 with motor and IR sensor Each 12 PRICED BID -PACKAGE II Page 10 of 19 Vendor Seal and Signature
11 164 Supply of PLC System Set Erection of PLC System Set Testing,Commissioning of PLC System Set 8 UPS supply: Supply of parallel redundant 167 UPS System Set 8 Erection of parallel redundant UPS 168 System Set 8 Testing,Commissioning of parallel 169 redundant UPS System Set 8 Supply of Dedicated batteries for UPS 170 System Set 8 Erection of Dedicated batteries for UPS 171 System Set 8 Testing,Commissioning of Dedicated 172 batteries for UPS System Set Supply of Emergency Push Button Each Erection of Emergency Push Button Each 32 Testing,Commissioning of Emergency 175 Push Button Each Supply of all type of cables required for automation of the terminal/depot viz. Power cables, control cables, signal cables, data communication cables, and special cables if any up to Main Junction box. Cabling from Main JB to individual instrument shall be part of respective instrument/ equipment Laying of all type of cables required for automation of the terminal/depot viz. Power cables, control cables, signal cables, data communication cables, and special cables if any up to Main Junction box. Cabling from Main JB to individual instrument shall be part of respective instrument/ equipment Testing,Commissioning of all type of cables Construction of Cable Trench including all material PRICED BID -PACKAGE II Page 11 of 19 Vendor Seal and Signature
12 180 Supply of cable trays 181 Erection of above item 182 Supply of Flame proof junction boxes 183 Erection of Flame proof junction boxes Testing,Commissioning Flame proof 184 junction boxes 185 Supply of Manual Call Points Each Erection of Manual Call Points Each 72 Testing,Commissioning of Manual Call 187 Points Each Supply of Pressure Switch Each Erection of Pressure Switch Each 24 Testing,Commissioning of Pressure 190 Switch Each Supply of Weather proof Junction boxes 192 Erection of Weather proof Junction boxes 193 Testing,Commissioningof Weatherproof Junction boxes 194 Supply of fire water diesel engine panel Each Erection of fire water diesel engine panel Each 20 Testing,Commissioning of fire water 196 diesel engine panel Each Supply of LRC /TAS servers Each Erection of LRC /TAS servers Each 16 Testing,Commissioning of LRC /TAS 199 servers Each Supply of client PC Each Erection of client PC Each Testing,Commissioning of client PC Each Supply of gateway servers Each Erection of gateway servers Each 16 Testing,Commissioning of gateway 205 servers Each 16 PRICED BID -PACKAGE II Page 12 of 19 Vendor Seal and Signature
13 TAS Software with license:supply of complete Terminal Automation Software with user license as defined in the specification for entire automation System(Terminal Automation Application Software, Operating System Software. RDBMS Software, Tank Farm Management System software, PLC Software and various instrumentation sub Systems etc complete) Installation of complete Terminal Automation Software with user license as defined in the specification for entire automation System (Terminal Automation Application Software, Operating System Software. RDBMS Software, Tank Farm Management System software, PLC Software and various instrumentation sub Systems etc complete) Testing & Commissioning of complete Terminal Automation Software with user license as defined in the specification for entire automation System (Terminal Automation Application Software, Operating System Software. RDBMS Software, Tank Farm Management System software, PLC Software and various instrumentation sub Systems etc complete) 209 Supply of Printer Each Erection of Printer Each Testing,Commissioning of Printer Each 16 Supply of 10/100 Fast Ethernet Stackable 212 manageable Switches Erection of 10 / 100 Fast Ethernet 213 Stackable manageable Switches PRICED BID -PACKAGE II Page 13 of 19 Vendor Seal and Signature
14 Testing,Commissioning 10 / 100 Fast Ethernet Stackable manageable Switches Supply of Enhanced UTP CAT 6 Structured Cabling with suitable end connection Erection of Enhanced UTP CAT 6 Structured Cabling with suitable end connection Testing,Commissioning of Enhanced UTP CAT 6 Structured Cabling with suitable end connection 218 LAN for interbldg. distance exceed 100 Meters:Supply of LAN Networking with fiber optics cable, CAT 6 Ethernet Cabling, UTP to Fiber optic convertor, LIU, mounting rack, coupler, connector, RJ 45 connectors, switches GI pipe, etc complete for connection between Control Room & Admin Building, S&D/ Planning Room wherever interbuilding distance exceeds 100 Meters 219 Laying of LAN Networking with fiber optics cable, CAT 6 Ethernet Cabling, UTP to Fiber optic convertor, LIU, mounting rack, coupler, connector, RJ 45 connectors, switches GI pipe, etc complete for connection between Control Room & Admin Building, S&D/ Planning Room wherever interbuilding distance exceeds 100 Meters PRICED BID -PACKAGE II Page 14 of 19 Vendor Seal and Signature
15 220 Testing,Commissioning of LAN Networking with fiber optics cable, CAT 6 Ethernet Cabling, UTP to Fiber optic convertor, LIU, mounting rack, coupler, connector, RJ 45 connectors, switches GI pipe, etc complete for connection between Control Room& Admin Building, S&D/ Planning Room wherever interbuilding distance exceeds 100 Meters LAN for TFMS to control room:supply of LAN Networking with fiber optics cable, CAT 6 Ethernet Cabling, UTP to Fiber optic convertor, LIU, mounting rack, coupler, connector, RJ 45 connectors, switches GI pipe, etc complete for providing Tank Farm Signal to pipeline Control Room Laying of LAN Networking with fiber optics cable, CAT 6 Ethernet Cabling, UTP to Fiber optic convertor, LIU, mounting rack, coupler, connector, RJ 45 connectors, switches GI pipe, etc complete for providing Tank Farm Signal to pipeline Control Room Lot 1 Lot Testing,Commissioning of of LAN Networking with fiber optics cable, CAT 6 Ethernet Cabling, UTP to Fiber optic convertor, LIU, mounting rack, coupler, connector, RJ 45 connectors, switches GI pipe, etc complete for providing Tank Farm Signal to pipeline Control Room Lot Supply of redundant Terminal server Each Erection of above item Each Testing,Commissioning of above item Each Supply of computer consoles Each 48 PRICED BID -PACKAGE II Page 15 of 19 Vendor Seal and Signature
16 228 Erection of above item Each Supply of FCU for MOVs Each Erection of above item Each Testing,Commissioning of above item Each Supply of DG sets Each Erection of above item Each Testing,Commissioning of above item Each Supply of AC Each Erection of above item Each Testing,Commissioning of above item Each 32 Supply of Control Station for the existing 238 MOVs Each Erection of Control Station for MOV Each 2 Testing & commissioning of Control 240 Station for MOV Each 2 Providing limit switches, auxiliary contactors, cabling etc. for connecting 241 PLC I/Os to existing motor operated Lot 4 Barrier Gates. 242 Erection of above item Lot Testing,Commissioning of above item Lot Modification in batch controller: Supplying of required hardware and software for necessary modifications in the existing batch controller in software and hardware firmware Lot Erection of above item Lot Testing,Commissioning of above item Lot Nozzle for Radar gauge on CRVT:Supply of necessary nozzles and accessories on the existing man hole/ dip gauge opening for installation of Radar gauge on CRVT,fixed cum floating roof TANKS Lot Erection of above item Lot 41 PRICED BID -PACKAGE II Page 16 of 19 Vendor Seal and Signature
17 249 Testing,Commissioning of above item Lot Nozzle for Temp. Sensor on CRVT:Supply of necessary nozzles and accessories on the existing man hole/ Dip gauge opening for installation of Averaging temperature sensor cum water probe on CRVT, horizontal, fixed cum floating roof TANKS Lot Erection of above item Lot Testing,Commissioning of above item Lot Nozzle for P.T on CRVT: Supply of nozzles and accessories on existing man holes for installation of Pressure transmitter on CRVT TANKS, horizontal A/G, fixed cum floating tanks Lot Erection of above item Lot Testing,Commissioning of above item Lot 41 Nozzle for radar gauge on FRVT:Supply of necessary nozzles and accessories on the 256 existing dip gauge opening for Lot 18 installation of Radar gauge on FRVT TANKS 257 Erection of above item Lot Testing,Commissioning of above item Lot Nozzle for temp.sensor on FRVT:Supply of necessary nozzles and accessories on the existing man hole/ Dip gauge opening for installation of Averaging temperature sensor cum water probe on FRVT TANKS Lot Erection of above item Lot Testing,Commissioning of above item Lot 18 PRICED BID -PACKAGE II Page 17 of 19 Vendor Seal and Signature
18 Nozzle for P.T on FRVT: Supply of nozzles and accessories on manhole for 262 Installation of Pressure transmitter on Lot 33 FRVT TANKS 263 Erection of above item Lot Testing,Commissioning of above item Lot Nozzle for TFMS in U/G tanks:supply of nozzles and accessories for installation of TFMS equipments in U/G tanks Lot Erection of above item Lot Testing,Commissioning of above item Lot Supply of Steel Structure for alterations in TLF platform Metric Ton Fabrication, Welding & Erection ofabove Metric Ton 32 item 270 Testing,Commissioning of above item Metric Ton 32 Modification of MCC Starter: Supply of items required for modification of MCC 271 Starter schemes for local Remote operation of pumps for sequencing and Auto operation. 272 Erection of above item 273 Testing,Commissioning of above item 274 Modification for fire engine panel: Supply of items required for modification of fire engine panel for local Remote operation of pumps and Auto operation. Lot Erection of above item Lot Testing,Commissioning of above item Lot Integration of VFD into TAS:Supply of items required for Integration of VFD into TAS including required cables Lot 5 PRICED BID -PACKAGE II Page 18 of 19 Vendor Seal and Signature
19 278 Erection of item required for Integration of VFD into TAS including required cables Lot 5 Testing,Commissioning of items 279 required for Integration of VFD into TAS Lot 5 including required cables Integration of MOV's into TAS:Supply of 280 items required for integration of MOV Lot 2 with TAS 281 Erection of above item Lot Testing,Commissioning of above item Lot Training Lot AMC for 5 years Lump sum 8 Grand total in words Grand Total Currency unit- Currency symbol- Note : Incase currency unit quoted in Un-priced bid is not matching with currency quoted in Priced bid, Currency unit quoted in unpriced bid shall be considered for evaluation and PO purpose. PRICED BID -PACKAGE II Page 19 of 19 Vendor Seal and Signature
Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5
Page 1 of 5 Vessel Name: Serial number MCU: Serial Number EPU: Serial Number Skid: Mains Supply: V AC @ Hz Software version MCU: Software version EPU: K-factor Cell: K-factor Skid Flowmeter: P/L Maximum
More informationSyncroFlo Municipal University and Hydraulic Institute, Pump Systems Optimization
SyncroFlo Municipal University and Hydraulic Institute, Pump Systems Optimization COURSE SYLLABUS September 16 th 18 th, 2013 9/16/13 Day One Hydraulic Institute Workshop (8:30am) PUMP SYSTEMS OPTIMIZATION:
More informationTANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel
TANK MANAGER FOR TWO TANKS OPERATING MANUAL 10/31/11 C-More T6C L color touch panel 1 TABLE OF CONTENTS GENERAL...3 INSTALLATION...4 STONE TEST PROCEDURE...7 OPERATIONAL SUMMARY...7 AUTO CARBONATION...10
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationAUTOMATIC GAS MANIFOLDS
AUTOMATIC GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com
More informationEN00 Pre-Instructional Survey
EN00 Pre-Instructional Survey Name: Date: 1. At 433 degrees F, a type J thermocouple with a 3 degree F reference junction will produce an output in millivolts that is most nearly to: a. 9.04 b. 10.51 c.
More informationMANUAL GAS MANIFOLDS
MANUAL GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com
More informationmy SYSTEM A guide to common applications in water distribution systems
my SYSTEM A guide to common applications in water distribution systems WWW.SINGERVALVE.COM INDEX This short guide is intended to offer guidance on some of the common problems, applications and questions
More informationDTG - LCD Digital Temperature Gauge USER MANUAL
DTG - LCD USER MANUAL Page 1 of 7 USERS GUIDE page 1. Description 3 2. Function 3 3. Safety Instruction 3 3.1. Safety Conventions 3 3.2. Proper Use 3 4. Installation 4 4.1. Unpacking 4 4.2. Storage 4 4.3.
More informationMiniature controls. Contactors. Overload relays. Starters. Control relays
Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power
More informationPressure Automated Calibration Equipment
GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationINSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:
PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)
More informationAutocalibration Systems For In Situ Oxygen Analyzers
Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from
More informationIE039: Practical Process Instrumentation & Automatic Control
IE039: Practical Process Instrumentation & Automatic Control IE039 Rev.001 CMCT COURSE OUTLINE Page 1 of 8 Training Description: Process Control & Instrumentation is becoming an increasingly important
More informationGas Network Craftsperson
Gas Network Craftsperson Unit EIAU06 Maintaining Instrumentation and Control Equipment Circuits This assessment specification has been developed as part of the network maintenance craftsperson standard
More informationInfrared Linescanners
Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories
More information11. Spare Parts. applications since applications since
2 8 2 6 20 2 8 0 5 6 8 9 2 2 25 7 8 9 5 0 2 2 7 . Spare Parts * C0 C02 C06 C0 C7 C C0 C5 C58 Article No. Description B-26 B-2009 Steam generation Steam cylinder CY DN20 compl. with electrodes and hand
More informationLPG DRIVER ATTENDED TRANSPORT LOADING
November 1993 Prepared By: Ken A. Steward. P.E. Linco-Electromatic, Inc. 4580 West Wall Street Midland, Texas 78703 LPG DRIVER ATTENDED TRANSPORT LOADING INTRODUCTION The safest and most accurate method
More informationDEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA
DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI 600036, INDIA Ref. No. CHE/17-18/CHE/006/GAIM/RAJN Date: 25 APRIL, 2018 Due date: 9 MAY, 2018 Item: High Pressure Gas Hydrate
More informationCPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 0700 67 Registered in England and Wales No. 05058855
More information660 Multipoint Electronic Level Switch
660 Multipoint Electronic Level Switch General Instructions The Multipoint Electronic Level Switch is a level sensing device which reads process level by capacitance measurement. Capacitance varies according
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure
More informationCONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES
I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical
More informationDual fuel Gas-Oil/Gas burner
Installation, use and maintenance instructions Dual fuel Gas-Oil/Gas burner MODEL GI/EMME 400 TYPE 496 T80 291 (6) TECHNICAL FEATURES Thermal power 116/232 465 kw - 100.000/200.000 400.000 kcal/h Fuels
More informationInstruction Manual Dräger MSI P7 and MSI P7 plus
Dräger MSI GmbH Rohrstraße 32 58093 Hagen Tel.: +49-2331 / 9584-0 Fax: +49-2331 / 9584-29 e-mail: info@draeger-msi.de D 923; Edition 2011-01-01 Content 1. General Hints Page 4 2. The Instrument 2.1 Front
More informationAutocalibration Systems for In Situ Oxygen Analyzers
Product Data Sheet PDS 106-340AC.A01 February, 2006 SPS 4001B, IMPS 4000 and MPS 3000 Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging
More informationArmfield Distillation Column Operation Guidelines
Armfield Distillation Column Operation Guidelines 11-2016 R.Cox Safety SAFETY GLASSES ARE REQUIRED WHEN OPERATING THE DISTILLATION COLUMN Wear gloves when mixing alcohol feedstock The column will become
More informationAUTOMATIC HOSE TEST UNIT, TYPE SPU
VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE
More informationSorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply
Sensen DCS Series General Purpose Systems Power Supply High power density / low ripple and noise High programming resolution with Ethernet interface Constant voltage and current mode Remote sensing Isolated
More information215 Liquid Handler Up-Grade Manual
BRUKER NMR 220 25 Liquid Handler Up-Grade Manual For Up-Grade to Run with XWINNMR Vers.. Manual # H977 The kit will include: H9770 BEST NMR Up-Grade Kit to No. Article Bruker # Comment 500mm Capillary
More informationAGW SYSTEMS. Blue Clock W38X
AGW SYSTEMS Blue Clock W38X Contents table BLUECLOCKS...3 THE EVOLUTION...4 WHAT S NEW!...5 HARDWARE...6 SOFTWARE...7 MULTI COMPANY...8 INSTANTLY...9 EVEN MORE!...10 WHAT S INSIDE HOW DOES IT WORK...11...12
More informationprocess measurement solutions The level solutions catalogue
process measurement solutions The level solutions catalogue Precision... level measurement & control... Powerful FMCW technology Radar level transmitter MRL700 Radar level transmitters Solartron Mobrey's
More informationIE011: Process Control & Instrumentation Technology
IE011: Process Control & Instrumentation Technology IE011 Rev.001 CMCT COURSE OUTLINE Page 1 of 8 Training Description: This intensive course covers fundamental and practical of instrumentation measurements
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at
More information14. Exploded View. Page 68
14. Exploded View Page 68 15. View of housing Page 69 11. Spare Parts HY05 HY13 55 E-2124010 Keys for safety, set=2pc. 54 E-2124012 Safety lock incl. 2 keys 1 B-3204031 1 B-2204101 1 B-2204111 1 2 B-2204105
More informationECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION
ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050
More informationModel PSI Compressor with 3-Gallon Air Tank 12VDC
Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationServicePlus S21R & S27R Series 2 Installation Instructions
ServicePlus S21R & S27R Series 2 Installation Instructions Horstmann Controls ServicePlus two channel service interval programmers have been developed to facilitate compliance with the Gas Safety (Installation
More informationTEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions
Technology Solutions TEK-THERMAL 1700B Thermal Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Thermal 1700B Thermal Mass Flowmeters,
More informationWATER INJECTION SYSTEMS - CORROSION MONITORING
Corrosion Management WATER INJECTION SYSTEMS - CORROSION MONITORING Overview Water, used for well injection is normally treated seawater and thus it is critical to control the corrosivity of the fluid,
More informationTH-1800-T TRX-700-CNG Converter
TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter
More informationCCT-7320/ROC-2313 Reverse Osmosis Controller
CCT-7320/ROC-2313 Reverse Osmosis Controller 1 General The instrument is a combined control instrument of a reverse osmosis controller and an on-line conductivity instrument. It can perform the operation
More informationanalytical bulk flow distance FLOW level pressure temperature industrial communication
analytical bulk flow distance level pressure temperature industrial communication isolv THERMAL MASS METER Measuring Principle Self-heated Sensor Reference Sensor isolv Thermal Mass Flow Meters have two
More informationPipe-Away Pressure Vacuum Vent /Conservation Vent
R R Pressure Vacuum Vent / End of Line Conservation Vent Flame Arrester with Pressure Vacuum Vent Pipe Away Pressure Vacuum Vent / Conservation Vent Vacuum Relief Vent Pressure Emergency Vent Free Vents
More informationSINGLE VALVE WITH LOW-FLOW BYPASS
CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size
More informationLocator Locator-D-Lux Air-Saver G1 Air-Saver G2
170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationA versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE
A versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE A versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE Contents The
More informationCENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES
P0170E-1.DOCX/08.16/MG CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES With a Central Gas Supply System, individual work places or gas take-off stations are supplied with gas through
More informationDescription. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.
DN 0 to 1000 - Serie K3 0 On-Off levels float control valve, closing at high level and opening at low level. Functions Prevents overflowing and closes at a constant and adjustable high level. Remains closed
More informationGRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz
GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical
More informationProducts for Cryogenic Applications
Products for Cryogenic Applications Cryogenic valves, self-operated regulators, differential pressure meters SMART IN FLOW CONTROL. Designed for cryogenic service Industry, medicine, supply engineering
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationPRE BID QUERIES FOR CNG & CITY GAS DISTRIBUTION FOR HYDERABAD. Clause No. Description in tender documents Clarifications / Request for change
Tender : Bid Document : BGL/100/2010-11 PRE BID QUERIES FOR CNG & CITY GAS DISTRIBUTION FOR HYDERABAD Sl. Clause Description in tender documents Clarifications / 1. ARTICLE 19 :Price If the contractor
More informationManual of Petroleum Measurement Standards Chapter 6 Metering Assemblies Section 3A Pipeline and Marine
Manual of Petroleum Measurement Standards Chapter 6 Metering Assemblies Section 3A Pipeline and Marine Loading/Unloading Measurement Systems Draft Edition January 2018 Introduction This standard serves
More informationSingle-Level Bill of Materials Report
Page 1 of 1 Target Part: 47500520001, C.1 (Engineering) Time Of Execution: 2013-08-03 00:01 CDT Use = False (5 of 5 total objects) View: With line no 0 47500520001 CENTAC CC700/C32MX3 1 47503396001 DRAWING
More informationH 2 O Bubble Chamber Superheated Active Target System. Safety and Systems Overview B. DiGiovine
H 2 O Bubble Chamber Superheated Active Target System Safety and Systems Overview B. DiGiovine Physics Division and Bubble Chambers April 2009 First Bubble Chamber Received Full Operation Authorization
More informationSCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE
SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE 1 TABLE OF CONTENTS 1. PURPOSE OF SUPPLY... 3 2. SYSTEM FUNCTIONING... 3 3. SYSTEM COMPONENTS... 4 4. BATTERY LIMITATIONS... 6 5. DOCUMENTATION...
More informationT i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)
RACEAMERICA T i m i n g S y s t e m s Demo Tree Controller Owner s Manual Models 3204D, 3204DW & 3204DX Rev D RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com
More informationQuickstart Installation Checklist (Please refer to operation manual for complete installation instructions)
Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions) 1. Uncrate blender from packaging. 2. Lift the blender and position over machine throat or floor
More informationOperational Settings:
instrucalc features more than 70 routines associated with control valves, ISO flow elements, relief valves and rupture disks, and calculates process data at flow conditions for a comprehensive range of
More informationSonoMeter 30 Energy Meters
Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications
More information5 Channel Calibrator
212 N. Woodwork Lane Palatine, IL 60067 800-223-3977 5 Channel Calibrator Part # 0724 User Manual Questions? Contact us at 800-223-3977 or online at http://www.cleanair.com/equipment/express/main.html
More informationHumiSys HF High Flow RH Generator
HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously
More informationScanFoam. Cleaning Equipment ApS. w w w. s c a n f o a m. c o m
ScanFoam Cleaning Equipment ApS w w w. s c a n f o a m. c o m Units List of Equipment 2015-06A ScanFoam ApS Skanderborg Denmark Phone: +45 86 57 25 99 Fax: +45 86 57 20 86 E-mail: anders.christensen@scanfoam.com
More informationSouth-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)
South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System Designed for: Dry or Preaction Fire Protection Systems (FPS) 1.0 Description of Work 1.1 The Fire Sprinkler Contractor shall provide
More informationMaxSB - Low Voltage Switchboard
BU 3101 Low Voltage Systems, March 2009 Low Voltage Systems MaxSB - Low Voltage Switchboard May 5, 2009 Slide 1 MaxSB Product Overview Description Value Rated Main bus current 1600A, 2000A, 3000A, 3200A,
More informationOC Panel High Limit Aquastat Kit, Manual Reset p/n
OC Panel High Limit Aquastat Kit, Manual Reset p/n 233202 Instruction Sheet APPLICATION The OC (Option Control) Panel High Limit Aquastat Kit provides electronic temperature sensing in a UL limit-rated
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationTips on Permanent Powered Fencing and Temporary Powered Fencing
Tips on Permanent Powered Fencing and Temporary Powered Fencing The following outlines various simple, yet proven, methods in constructing both fixed and portable fencing systems as well as providing information
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationSchedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT
S. No 1 Description Calorimeter The Unit should be designed for the accurate determination of the calorific value of liquid and solid hydrocarbons and other fuels. Specifications: A temperature-controlled
More informationModelling Today for the Future. Advanced Modelling Control Techniques
CwMAG 1 st Autumn Conference 2012 Modelling Today for the Future Advanced Modelling Control Techniques What are advanced modelling controls? Why do we have them? How can we use them? What are the differences
More informationIE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications
IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications IE073 Rev.001 CMCT COURSE OUTLINE Page 1 of 5 Training Description: The hazardous-area circuits 'float' i.e. is
More informationShanghai AEAD Technology Co., Ltd Professional Manufacturer of Flow, Level, Pressure, Temperature
Shanghai AEAD Technology Co., Ltd Professional Manufacturer of Flow, Level, Pressure, Temperature Tel: 86-21-5197 8797 Fax: 86-21-5197 8799 Email: shaead@163.com Site: www.shaead.com/english Flow Meter
More informationWater Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers
Water Solenoids Safety Valves Air Valves Meters Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers Pneumatics Steam Traps Fire Hydrants Boiler Valves Water Metering Systems By combining high
More informationThe HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator
The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric
More informationAutomatic Isokinetic Sampler. ST5 Evo
Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,
More informationMultiple Pressure Booster Systems With Variable Speed Controller Type BL
Multiple Pressure Booster Systems With Variable Speed Controller Type BL General Characteristics - Single or multistage pumps - Horizontal or vertical mounting - Total head 30m ~ 250m - Material construction:
More informationProMinent Gas Chlorination
ProMinent Gas Chlorination ProMinent Australia Head Office - Sydney Unit 4, 4 Narabang Way BELROSE NSW 2085 PO Box 85, BELROSE WEST NSW 2085 Ph: (02) 9450 0995 Fax: (02) 9450 0996 Fax (02) 9450 0994 -
More informationWe measure it. For gas and water installers. testo hpa. bar
Pressure measuring instruments For gas and water installers testo 312-2 hpa testo 312-3 testo 312-4 bar C testo 312-2 / testo 312-3 Pressure meters for gas and water fitters testo 312-2 testo 312-2, fine
More informationTactical Advance Series Tactical Advance HD Series. Simplifying CNC Plasma Cutting.
Tactical Advance Series Tactical Advance HD Series www.tacticalcnc.com Technology at work for you What makes the Tactical CNC Advantage and Advantage HD Series the best automated plasma cutting solution
More informationDUPLEX PRESSURE REDUCING SET
DUPLEX PRESSURE REDUCING SET Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com
More informationMAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump
A. PARTS MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump Assembly & Operating Instructions Parts for liquid chlorine pump head 1pc. 1/4 poly delivery tubing, 4 meters 1pc. drum
More informationCoriolis Mass Flow Meter
Coriolis Mass Flow Meter TMFW Series Mini Type Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;
More informationDraw-wire system SZG165
Draw-wire system SZG165 www.wachendorff-automation.com Wachendorff Automation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and customer versions
More informationIE068: Process Instrumentation Technology
IE068: Process Instrumentation Technology IE068 Rev.002 CMCT COURSE OUTLINE Page 1 of 8 Training Description: This course covers fundamental and practical of instrumentation measurements including Flow
More informationSpare parts list ( ) Spare parts list HDS 990
Spare parts list (5.952-855.0) Spare parts list HDS 990 13.10.2014 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 990 (5.952-855.0)... 6 10 Individual parts... 7 49 Spare
More informationDigi Connect ME 9210 Linux: serial port 2 for JTAG modules
Digi Connect ME 9210 Linux: serial port 2 for JTAG modules Document History Date Version Change Description 08/05/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents...
More informationProduct Overview. Product Description CHAPTER
CHAPTER 1 This chapter provides a functional overview of the Cisco Redundant Power System 2300 and covers these topics: Product Description, page 1-1 Features, page 1-3 Supported Devices, page 1-4 Deployment
More informationElectronic gas volume corrector model DGVC-04
Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector
More informationAmerican made since 1954
Hampden Engineering Corporation LOOK TO HAMPDEN FOR YOUR TRAINING NEEDS! Hampden s selection of Instrumentation and Process Control Training equipment is far larger than we are able to show you in this
More informationLP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal Projects, New Zealand
Proceedings World Geothermal Congress 2010 Bali, Indonesia, 25-29 April 2010 LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal
More informationCSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator
CSO/STORMWATER MANAGEMENT HYDROVEX HHV-E Vortex Driven Regulator HYDROVEX HHV-E VORTEX DRIVEN REGULATOR APPLICATION The hydro electronic HYDROVEX HHV driven regulator, type E is specially designed for
More informationVERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.
SUMP PUMP PIT UNIT FEATURES All needed parts are assembled and united as a sump pit and easy to install for short period. Sump tank is made of SUS with epoxy coating and pipe is integrated by stainless
More informationTransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features
Applications The TransPort PT878GC clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive
More informationManifolds & pressure reducing sets
Manifolds & pressure reducing sets Automatic Changeover Manifold (Electronic) Providing continuous supply of medical gases Pneumatech Medical Gas Solutions (PMGS) PureGAS Manifolds provide a duty or standby
More informationT EK-SUB 4800C 19 mm Submersible Level Transmitter
Technology Solutions T EK-SUB 4800C 19 mm Submersible Level Transmitter Instruction Manual Document Number: IM-4800C www.tek-trol.com Table of Contents 1 Safety Instructions... 2 1.1 Intended Use... 2
More information