Index. 1. Introduction. 2. Available models. 3. Sterilization Programs. 4. Mechanical features. 5. Electrical features

Size: px
Start display at page:

Download "Index. 1. Introduction. 2. Available models. 3. Sterilization Programs. 4. Mechanical features. 5. Electrical features"

Transcription

1

2 Index 1. Introduction 2. vailable models 3. Sterilization Programs 4. Mechanical features 5. Electrical features 6. Laboratory Version with io Hazard Risk Special Specifications 7. Equipment markings 8. Network onnections 9. vailable accessoires 1. Warranty M15/2 E 6/4/1 Product escription entroclave Series 2/3

3 1. Introduction These equipments have a high quality standard, are fully tested in order to grant a high service level and a good performance. The steam sterilizers entroclave series has been designed to answer the most demanding requirements of steam sterilization of medical devices and in accordance with the European and ISO standards and regulations. The steam sterilizer entroclave is also manufactured in a version for Laboratory purposes. It is with pride and satisfaction we note that this equipment has deserved your approval and preference, therefore we will do everything on our hands to maintain the trust in our organization. The steam sterilizers entroclave series is particularly directed to provide sterilization service to the following market segments: Small/medium sized health centres Small/ Medium sized clinics Hospital Specific health care services with small/ medium sterilization volume Laboratories, for the sterilization of glassware, liquids, instruments, equipment and thermo sensitive materials Sterilization of io hazard material. The steam sterilizers entroclave series considers the current concerns in: Validation of sterilization processes, and quality management system certification. Water and energy savings Safety, reliability and ease of use M15/2 E 6/4/1 Product escription entroclave Series 3/3

4 2. vailable models The entroclave series is a free floor standing, front loading sterilizer, prepared for to sterilize hospital, Laboratory and io hazard instruments and materials. The equipment has a built in steam generator. The available models in the steam sterilizers entroclave series are listed here: RN SERIES MOEL HSP 1R (One door) HSP 2R (Two doors) Lab 1R (One door) J entroclave Lab 2R (Two doors) Lab io 1R (One door) Lab io 2R (Two doors) M15/2 E 6/4/1 Product escription entroclave Series 4/3

5 3. Sterilization Programs The steam sterilizers entroclave series has the following available working programs, accessible to the operator: Executable cycles and corresponding phases 3.1 Hospital standard version The steam sterilizer entroclave includes in Hospital standard version the programming of 9 working cycles that are intended to answer all foreseeable needs in steam sterilization process: YLE 1: Heating up cycle. ycle for the pre-heating of the sterilizer chamber Profile of cycle 1 - Sterilization at 121º H I J K E Point Pressure Point Pressure Point Pressure - 2 E - 2 H I J 15 - K M15/2 E 6/4/1 Product escription entroclave Series 5/3

6 YLE 2: owie & ick test cycle ycle to detect air pouches, vacuum pump malfunction and verification of steam penetration conditions Profile of cycle K L - Sterilization at 134º I J E H M N Point Pressure Point Pressure Point Pressure K L H 15 M I - N 11 E 15 J - 18 YLE 3: Vacuum test cycle Verification test to check for pressure leaks in mechanical circuits and in the sterilizers chamber. - Execution of the test Profile of cycle 3 Point Pressure M15/2 E 6/4/1 Product escription entroclave Series 6/3

7 YLE 4: ycle for wrapped Instruments ycle for glassware, utensils and wrapped surgical instruments. Profile of cycle N O - Sterilization at 134º H K L M E I J P Q Point Pressure Point Pressure Point Pressure M H N I 12 2 O 341 J 2 P 9 2 E 12 2 K 1 Q 11 2 L YLE 5: ycle for wrapped Textiles Sterilization cycle for wrapped textiles. Profile of cycle N O - Sterilization at 134º H K L M E I J P Q Point Pressure Point Pressure Point Pressure M H N I 18 2 O 341 J 2 P 2 E 18 2 K 1 Q 11 2 L M15/2 E 6/4/1 Product escription entroclave Series 7/3

8 YLE 6: ycle for ontainers ycle for instruments in containers, particularly heavy loads Profile of cycle E - Sterilization at 134º - Ventilation I H J K L Point Pressure Point Pressure Point Pressure 3 38 E I J K 7 - H L 7 YLE 7: ycle for Prions reutzfeldt-jakob isease Special cycle for instruments Profile of cycle N O - Sterilization at 134º H K L M E I J P Q Point Pressure Point Pressure Point Pressure M H N I 12 2 O 341 J 2 P 9 2 E 12 2 K 1 Q 11 2 L M15/2 E 6/4/1 Product escription entroclave Series 8/3

9 YLE 8: ycle for wrapped temperature Sensitive Materials ycle for thermo-sensitive wrapped materials. Profile of cycle 8 - Sterilization at 121º K L N O H M E I J P Q Point Pressure Point Pressure Point Pressure M H N I 12 2 O 249 J 2 P 9 2 E 12 2 K 1 Q 15 2 L YLE 9: Rapid cycle ycle for non-wrapped surgical instruments Profile of cycle Sterilization at 121º E H I Point Pressure Point Pressure Point Pressure - 2 E - 18 H I M15/2 E 6/4/1 Product escription entroclave Series 9/3

10 YLE 16: ycle for cleanness of the chamber (maintenance) ycle for the cleanness of the sterilization chamber. - Open the load door - lose the load door Note: s option it is possible to provide other sterilization cycles, in accordance with client specification. 3.2 Laboratory version YLE 1: Heating up cycle. ycle for the pre-heating of the sterilizer chamber Profile of cycle 1 - Sterilization at 121º H I J K E Point Pressure Point Pressure Point Pressure - 2 E - 2 H I J 15 - K M15/2 E 6/4/1 Product escription entroclave Series 1/3

11 YLE 2: owie & ick test cycle ycle to detect air pouches, vacuum pump malfunction and verification of steam penetration conditions Profile of cycle K L - Sterilization at 134º I J E H M N Point Pressure Point Pressure Point Pressure K L H 15 M I - N 11 E 15 J - 18 YLE 3: Vacuum test cycle Verification test to check for pressure leaks in mechanical circuits and in the sterilizer chamber. - Execution of the test Profile of cycle 3 Point Pressure M15/2 E 6/4/1 Product escription entroclave Series 11/3

12 YLE 4: ycle for wrapped Instruments ycle for glassware, utensils and wrapped surgical instruments. Profile of cycle N O - Sterilization at 134º H K L M E I J P Q Point Pressure Point Pressure Point Pressure M H N I 12 2 O 341 J 2 P 9 2 E 12 2 K 1 Q 11 2 L YLE 8: ycle for wrapped temperature Sensitive Materials ycle for thermo-sensitive wrapped materials. Profile of cycle 8 - Sterilization at 121º K L N O H M E I J P Q Point Pressure Point Pressure Point Pressure M H N I 12 2 O 249 J 2 P 9 2 E 12 2 K 1 Q 15 2 L M15/2 E 6/4/1 Product escription entroclave Series 12/3

13 YLE 11(*): Laboratory cycle. Pre vacuum and fast exhaustion Profile of cycle 11 - Sterilization 121º E Point Pressure Point Pressure Point Pressure E YLE 12(*): Laboratory cycle. Pre steam and fast exhaustion Profile of cycle 12 - Sterilization 121º Point Pressure Point Pressure M15/2 E 6/4/1 Product escription entroclave Series 13/3

14 YLE 13(*): Laboratory cycle. Pre vacuum and slow exhaustion Profile of cycle 13 - Sterilization 121º E Point Pressure Point Pressure Point Pressure E YLE 14 (*): Laboratory cycle. Pre steam and slow exhaustion Profile of cycle 14 - Sterilization 121º Point Pressure Point Pressure (*) and Sterilization temperature can be selected by user, for cycles nº 11 to nº14. M15/2 E 6/4/1 Product escription entroclave Series 14/3

15 YLE 16: ycle for cleanness of the chamber (maintenance) ycle for the cleanness of the sterilization chamber at day start, when chamber is cold. - Open the load door - lose the load door Note: s option it is possible to provide other sterilization cycles, as client specification. The user that knows the password has permission to alter parameters (time and temperature of sterilization, designation and description of Laboratory cycles. The parameters by default are the ones mentioned above. 3.3 Laboratory version with io hazard risk YLE 1: Heating up cycle. ycle for the pre-heating of the sterilizer chamber Profile of cycle 1 - Sterilization at 121º H I J K E Point Pressure Point Pressure Point Pressure E H I J K 15 M15/2 E 6/4/1 Product escription entroclave Series 15/3

16 YLE 2: owie & ick test cycle ycle to detect air pouches, vacuum pump malfunction and verification of steam penetration conditions Profile of cycle K L - Sterilization at 134º I J E H M N Point Pressure Point Pressure Point Pressure K L H 15 M I - N 11 E 15 J - 18 YLE 3: Vacuum test cycle Verification test to check for pressure leaks in mechanical circuits and in the sterilizer chamber. - Execution of the test Profile of cycle 3 Point Pressure M15/2 E 6/4/1 Product escription entroclave Series 16/3

17 YLE 1: ycle for iologic risk level 3 ycle for materials of io hazard risk level 3 Profile of cycle E - Sterilization at 134º - Rapid Exhaust Point Pressure Point Pressure Point Pressure E YLE 1 (*)- LTERNTIVE: ycle for iologic risk level 3 ycle for materials of io hazard risk level 3 Profile of cycle E - Sterilization at 134º - Rapid Exhaust Point Pressure Point Pressure Point Pressure 12 E (*) and Sterilization temperature can be selected by operator M15/2 E 6/4/1 Product escription entroclave Series 17/3

18 YLE 11: ycle for iologic risk level 3 ycle for materials of io hazard risk level 3 Profile of cycle E - Sterilization at 134º - Rapid Exhaust Point Pressure Point Pressure Point Pressure E YLE 11 (*)- LTERNTIVE: ycle for iologic risk level 3 ycle for materials of io hazard risk level 3 Profile of cycle E - Sterilization at 134º - Rapid Exhaust Point Pressure Point Pressure Point Pressure E (*) and Sterilization temperature can be selected by operator M15/2 E 6/4/1 Product escription entroclave Series 18/3

19 YLE 16: ycle for cleanness of the chamber (maintenance) ycle for the cleanness of the sterilization chamber at day start, when chamber is cold. - Open the load door - lose the load door Note: s option it is possible to provide other sterilization cycles, as per client specification. M15/2 E 6/4/1 Product escription entroclave Series 19/3

20 4. Mechanical features 4.1 imensions The available models in the steam sterilizers entroclave series are listed here: RN SERIES MOEL HSP J entroclave L L IO STERILIZER IMENSIONS (height x width x depth.) ( cm ) 155x64x87 The chamber dimensions and capacities for each model of the sterilizer entroclave series are listed in the following chart: RN SERIES MOEL HSP J entroclave L L IO HMER HMER IMENSIONS PITY (diameter x depth.) ( litres ) ( cm ) 4x67 83 M15/2 E 6/4/1 Product escription entroclave Series 2/3

21 The usable chamber dimensions and capacities for each model of the sterilizer entroclave series are listed in the following chart: RN SERIES MOEL HSP J entroclave L L IO HMER HMER USLE USLE IMENSIONS PITY (diameter x depth) ( litres ) ( cm ) 37x Other mechanical features The sterilization body consists of a chamber and integral jacket that assures a high heating efficiency and uniform temperature distribution inside the chamber. The chamber is built in ISI 316 stainless steel and the jacket is built in ISI 34 stainless steel. The door is entirely built in stainless steel, thus the surface of contact with steam is in stainless steel ISI 316. The sterilization chamber, along with the rest of the components, is horizontally mounted in a structure entirely built in stainless steel ISI 34. To the sterilization chamber is adapted a loading system that allows condensation to the drainage and free flow of steam amongst the entire load. The sterilization chamber has an electrolytic polishing. The door(s) and its (their) support structure was designed in a way to assure its (their) perfect functioning and possess the necessary sturdiness to resist the pressure variations during normal operation. The groove that holds the chamber-sealing gasket is calibrated and planed. The door(s) sealing gasket(s) is (are) made of high temperature resistant silicone, and easy to replace, inspect and clean, not needing for such to dismantle any kind of door support or fixings. The frontal cover of the sterilizer is made of ISI 34 stainless steel. M15/2 E 6/4/1 Product escription entroclave Series 21/3

22 The door panel gives the equipment a modern and functional design. The sterilizer is equipped with a,1 µm (micron) bacteriological filter to equalize the chamber pressure to atmospheric at the end of drying phase, for admission of sterile air into the chamber. 5. Electrical features 5. 1 Safety and safety devices The sterilizer chamber and the jacket are each equipped with safety valve against overpressure with automatic differential discharge type and manual command opening for inspection and verification. The steam sterilizer entroclave is equipped with devices that allow the detection of: Electric power failure Temperature probe malfunction Pressure transducers malfunction Overpressure inside the jacket Overpressure inside the sterilization chamber Water lack Emergency pushbuttons Jacket/hamber pressure safety valve Steam generator pressure safety valve Steam generator water level control and safety devices Steam generator thermal protection safety device (Optional) Whenever one of these failures is detected the cycle is interrupted. In the over pressure cases, the steam flow is turned off. The steam generator incorporates a water level safety device that automatically prevents the starting and the function of the steam generator and switch off the heating element in case of water lack. dditionally and as an optional can be mounted, the thermal protection safety device that in case of a failure of the water level safety device switch off the heating elements. M15/2 E 6/4/1 Product escription entroclave Series 22/3

23 The steam inlets into the sterilization chamber are placed asymmetrically in its lateral side. Pressure and temperature are separated and individually controlled in the chamber and jacket within the pressure and temperature range. or the Hospital version, the parameters of the different cycles remain unchangeable. Sterilizer is equipped with emergency stop buttons, in the load and unload side, that turn off the power supply to the machine. The entroclave is equipped with a mechanical lock device that keeps the door from opening, while there is pressure inside the sterilizer chamber. In the progress of a cycle, the door locking mechanism prevents its opening if user tries to open the door. In any case the control system will open the chamber exhaust valve, putting the sterilizer chamber to atmospheric pressure and aborting the sterilization cycle if the user succeeds to overcome the locking mechanism. In the cooling and condenser tank, the water level safety device prevents the system against water lack and the water temperature thermostat; control the water temperature in the tank, for to grant an adequate water temperature for the liquid ring vacuum pump and the cooling system, on the benefit of water consumption saving. 5.2 INSTRUMENTTION N MONITORIN ETURES The pressure and temperature into the sterilization chamber and into the jacket can be permanently displayed at the touch screen of the operator-interface console (in hpa and º respectively). In the operator-interface console, can also be permanently displayed all the relevant information regarding the progress of the various cycle phases as well as all failures and anomalies. The process can be graphically displayed in real time, exhibiting temperature and pressure in function of cycle time. Through the touch screen keyboard of the operator-interface console it is possible to introduce cycle data, command selection and call any intended information to be displayed. The printer can output detailed reports on all cycle phases and the eventual failures with corresponding date and time. chart of the evolution, during the cycle, of pressure and temperature inside the sterilization chamber versus time can also be printed. M15/2 E 6/4/1 Product escription entroclave Series 23/3

24 The machine registers a count of the number of processed sterilizations. t the unload side the pressure into the chamber can be permanently displayed, as well as the pressure into the double body (jacket). The temperature probes are of the type PT1, class, one for control and another for registry of sterilization chamber temperature. s an option, it can be fitted a PT 1 product probe. Pressure transducers are used one in the sterilization chamber and another at the double body (jacket), have a scale of to 4 hpa (absolute). Normalized validation ports for external temperature and pressure sensors for validation and qualification purposes, as per EN 285 standard. Information available in the operator-interface console of the unload door side: losed doors ycle in progress ycle complete ailure occurrence (Error Message) oor open Pressure (in hpa) chamber/jacket hamber temperature Jacket temperature (Optional) M15/2 E 6/4/1 Product escription entroclave Series 24/3

25 5.3 Performance and control The steam sterilizer is equipped with a microprocessor that is programmed in a way to assure a repeatable process even with variable loads. The microprocessor controls in an adequate manner the pressure and temperature variations in a way that the programmed cycle is executed precisely from beginning to end. Energy savings are equally assured, as only the strictly necessary power to the process is used. The vacuum pump allows a through drying of the sterilized materials and utensils. The sterilizer is fitted with a liquid ring vacuum pump, that is designed to attain a final pressure of,33 bar (33 mbar) absolute pressure, or a relative pressure of,98 bar (98 mbar). The cooling and condenser tank system, incorporate three different systems: cooling and condenser system that cools down the temperature of the steam and liquid effluents coming from the exhaustion. cooling and condenser system that cools down the steam and gaseous effluents before the vacuum pump. water level safety device prevents the system against water lack and the water temperature thermostat; control the water temperature in the tank, for to grant an adequate water temperature for the liquid ring vacuum pump and the cooling system, on the benefit of water consumption saving. Temperature control is indicated with a resolution of,1 º. Pressure control is indicated with a resolution of 1 hpa. ailure and statistics are permanently registered in memory. Note: The sterilizer can process various fixed cycles and cycles with programmable parameters by the user, depending on version (Hospital, Laboratory or Laboratory with biohazard risk) or the client s specifications. or the cycles programmed by user, once the cycle is defined it is kept in the microprocessor s memory, remaining the active cycle until the next modification. The operator does not have to alter the active cycle unless it is desired. The temperature of the sterilization plateau is calculated by factor, allowing, in this way, to assure that, in the beginning of the sterilization time count, the temperature of the load is, in all, within the safety plateau both the temperature in the outskirts and on its inside (or Laboratory Programs). M15/2 E 6/4/1 Product escription entroclave Series 25/3

26 Pressure and temperature control of the sterilization chamber and of the double body (jacket) are separately achieved, as to assure that temperature and pressure values in the jacket are in the same range as the ones selected for the chamber s sterilization plateau. 5.4 Environmental conditions Ensure that the equipment-operating environment meets the following conditions: mbient temperatures ranging from 5 to 35 º Relative humidity lower than 8% 6. Laboratory version with io hazard risk Special specifications The sterilizer with special cycles for to process io hazard materials has a special design in order to prevent any contamination once the io hazard material is proper placed in the chamber of the steam sterilizer and the cycle is started. To grant this purpose the steam sterilizer incorporates two different systems, description as follows: System to prevent any contamination, from the gaseous effluents coming from the vacuum and exhaust. ny gas or steam coming from the chamber, after the cycle is started, is filtered on HEP filter,1 µm (micron) before exhaustion, so the contamination is prevented. The HEP filter is contained in a special stainless steel body with sealing by means of a clamp system. The filter at the end of each cycle is automatically sterilized, and a special design allows to do the sterilization of the filter in manually way. The gaseous effluents before discharging from the steam sterilizer are cooled down at the cooling and condenser system. M15/2 E 6/4/1 Product escription entroclave Series 26/3

27 System to prevent any contamination, from the liquid effluents that comes from the discharge and drain. ny liquid effluent coming from the chamber is collected in a small chamber, surrounded by a steam jacket assuring that the liquid effluent is automatically sterilized during the cycle before to be discharged at the end of each cycle through the drain system. special design allows to do the sterilization of the liquid effluent in manually way. The liquid effluents before discharging from the steam sterilizer are cooled down at the cooling and condenser system. 7. Equipment markings The horizontal steam sterilizers entroclave series has been designed and built to comply with the following directives: EUROPEN IRETIVE IRETIVE NUMER O THE NOTIIE NNEX OR MOULE ORNIZTION 93/42/EE II 12 27/47/E II 12 97/23/E 1155 The steam sterilizers entroclave series is compliant with the following technical standards: NP EN 285: Sterilization. Steam sterilizers. Large sterilizers. SME Sec. VIII e II SME oiler and pressure vessel code Section VIII and II. M15/2 E 6/4/1 Product escription entroclave Series 27/3

28 Electrical Safety: EN :25 Safety Requirements for electrical equipment for measurement, control and Laboratory use. Particular requirements for sterilizers and washer-disinfectors used to treat medical materials. EN 611-1:21 Safety requirements for electrical equipment for measurement, control and Laboratory use. eneral Requirements. Electromagnetic ompatibility EN :26 Electrical equipment for measurement, control and Laboratory use EM Requirements Part 1: eneral Requirements. EN 6-3-2:26 Electromagnetic compatibility (EM Part 3-2: Limits Limits for harmonic current emissions (Equipments input current 16 per phase). EN 6-3-3: :21+ 2:25. Electromagnetic compatibility (EM) Part 3: Limits Section 3: Limitation of Voltage fluctuations and flicker in low voltage supply systems for equipments with rated current t 16. The production of the steam sterilizer entroclave series is covered by the quality management system implemented in our company and complies with the following standards: NP EN ISO 91 Quality management systems Requirements ISO Quality System Medical evices Particular Requirements of ISO 91 This certificate has been given to the manufacturer by the ertification ody SS UKS. M15/2 E 6/4/1 Product escription entroclave Series 28/3

29 8. Network onnections Electrical connection Standard Version: Three-phase connection 4 V ~ 3 + N + PE, 5 Hz, with a 25 circuit breaker and a 3 m differential protection. Heating elements: 6 kw, (optionally: 9 kw). Other electrical power supply connections can be provided. Water connection 3/4 SP pipe with female valve at ground level, or at wall. Pressure: 3 to 6 bar rain connection 2 galvanized pipe or equivalent, resistant to a minimum temperature of 1 º with a 2 SP female thread at ground level, drain with siphon, totally independent on other discharges. M15/2 E 6/4/1 Product escription entroclave Series 29/3

30 9. vailable accessories The standard accessories available for the steam sterilizers entroclave series are as follows: exterior loading car rolling load platform load baskets water softener igital printer The company may provide, under request, any other types or variations in accessories, to be manufactured. 1. Warranty The steam sterilizers entroclave series have a warranty period of two years. M15/2 E 6/4/1 Product escription entroclave Series 3/3

31

CO2 incubator with additional process controls

CO2 incubator with additional process controls CB series 150 C2 incubators C2 incubator with additional process controls The BINDER CB series C2 incubator is the premium class among the C2 incubators. It is suitable for all sensitive incubation applications

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Related Products: Auto Drain Valve. Model/Specifications. Model

Related Products: Auto Drain Valve. Model/Specifications. Model Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

AES-28/50/75/110/150 RFG Sterilization Autoclaves with counter pressure and fast cooling

AES-28/50/75/110/150 RFG Sterilization Autoclaves with counter pressure and fast cooling AES-75 RFG Advantages: Reduces the total cycle time until 50%. At the end of the process you can manipulate the sterilized materials thanks to output temperature set point. This equipment is design to

More information

COSMO INSTRUMENTS CO., LTD.

COSMO INSTRUMENTS CO., LTD. Specification Sheet COSMO AIR LEAK TESTER ModelLS-1861 Meets SI Unit Requirement Improved accuracy with the new Master-Preset compensation feature Compensates for environmental changes Improves cycle time

More information

Technical Information Conducal CLY421

Technical Information Conducal CLY421 TI00496C/07/EN/01.12 71142150 Products Solutions Services Technical Information Conducal CLY421 Conductivity calibration set for ultrapure water applications Factory calibrated measurement box Certified

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

AES 28/50/75/110/150 RFG Sterilization Autoclaves with counter pressure and fast cooling

AES 28/50/75/110/150 RFG Sterilization Autoclaves with counter pressure and fast cooling AES 75 RFG Advantages: Total flexibility adjusting the pressures on each cycle phases. Three settable pressures: on heating phase, on sterilizing phase and on cooling phase. Reduces the total cycle time

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

PERFORM Operating Document

PERFORM Operating Document PERFORM Operating Document Use and Maintenance of CO 2 Incubator PC-POD-CA-007-v02 Revision History Version Reason for Revision Date 01 New POD 30-Sep-13 02 Minor revisions for section 2.3, 3.1, 4.3. 14-April-16

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

Sanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Sanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems Pneumatic Retractable Fittings SensoGate W 3 H Sanitary pneumatic retractable fitting for use with Unical 9 and Uniclean 9 automated control systems Easy installation offers genuine plug & play. The central

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

Series Environmental Chambers

Series Environmental Chambers 3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

NEW: CO2 incubator with sterilizable sensor

NEW: CO2 incubator with sterilizable sensor CB series - NEW 160 C2 incubators NEW: C2 incubator with sterilizable sensor The new CB series offers optimal growth conditions for cell cultures. The ANTI.PLENUM concept, the 180 C sterilization routine

More information

CO2 incubator with additional process controls

CO2 incubator with additional process controls CB series 53 C2 Incubators C2 incubator with additional process controls The BINDER CB series C2 incubator is the premium class among the C2 incubators. It is suitable for all sensitive incubation applications

More information

Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas

Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas Pneumatic Retractable Fittings Pharm Food SensoGate W 3 H Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas Easy installation and clear hose connections offers

More information

NEW: CO2 incubator with sterilizable sensor

NEW: CO2 incubator with sterilizable sensor CB series - NEW 160 C2 Incubators NEW: C2 incubator with sterilizable sensor The new CB series offers optimal growth conditions for cell cultures. The ANTI.PLENUM concept, the 180 C sterilization routine

More information

6200 Isoperibol Calorimeter Model Number: 6200

6200 Isoperibol Calorimeter Model Number: 6200 Parr Instrument Company 6200 Isoperibol Calorimeter Model Number: 6200 Tests Per Hour: 4 8 Operator Time Per Test: 6 Minutes Precision Classifcation: 0.05 0.1% Class Jacket Type: Isoperibol, Water Jacket

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Operating Manual VSA100A. tina29e1 ( )

Operating Manual VSA100A. tina29e1 ( ) Operating Manual Incl. EU Declaration of Conformity Vacuum Switch VSA100A tina29e1 (2017-05) 1 Product Identification In all communications with INFICON, please specify the information on the product nameplate.

More information

Hand-held pressure calibrator with integrated pump Model CPH6600

Hand-held pressure calibrator with integrated pump Model CPH6600 Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control

More information

Discussion and guidance on the definition and qualification of porous loads

Discussion and guidance on the definition and qualification of porous loads SUMMARY Porous Loads requiring Sterilisation are often a Critical Control Point for the manufacture of Sterile products. Particularly Aseptically filled products. Regulatory guidance in this area is not

More information

VSR modulating valves with membrane actuator

VSR modulating valves with membrane actuator Modulating valves are used in process technology to control process parameters such as temperature, pressure or flow when handling liquid and gaseous media. uth's team of design and process engineers have

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Pneumatic retractable fitting for simple commercially available control units or process applications

Pneumatic retractable fitting for simple commercially available control units or process applications Pneumatic Retractable Fittings hem Energy Pharm Food Water SensoGate W 3 Pneumatic retractable fitting for simple commercially available control units or process applications Variable and reasonably priced

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung: Drying ovens www.matronic.se FD series Drying ovens with forced convection FD series units are primarily used in applications needing rapid drying and sterilization. Totally homogenous temperature distribution,

More information

3M Steri-Vac Sterilizer/Aerator GSX Series. For Life Science Applications. Product. Profile

3M Steri-Vac Sterilizer/Aerator GSX Series. For Life Science Applications. Product. Profile M Steri-Vac Sterilizer/Aerator GSX Series Product Profile Product Profile M Steri-Vac Sterilizer/Aerator GSX Series ethylene oxide (EO) sterilizer/aerators are designed to be used with M Steri-Gas EO Gas

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions VS18/26 with PROFINET and EtherNet/IP Interface ATEX Installation Instructions INDEX 1. INTENDED USAGE 3 2. OPERATING MANUAL ATEX 4 2.1 General conditions 4 2.2 Installation 5 2.3 Operating 5 2.4 Failures

More information

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products Saturn Evo SATURN EVO COLOR A N A E S T H E S I A S Y S T E M i n t e l l i g e n t s i m p l i c i t y Manufacturer of high quality anaesthesia products SATURN EVO COLOR PATIENT SAFETY AND USER PATIENT

More information

deltaflowc deltaflowc Venturi or Probe

deltaflowc deltaflowc Venturi or Probe deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc

More information

We measure it. For gas and water installers. testo hpa. bar

We measure it. For gas and water installers. testo hpa. bar Pressure measuring instruments For gas and water installers testo 312-2 hpa testo 312-3 testo 312-4 bar C testo 312-2 / testo 312-3 Pressure meters for gas and water fitters testo 312-2 testo 312-2, fine

More information

PERFORM Operating Document

PERFORM Operating Document PERFORM Operating Document Use and Maintenance of CO 2 Incubator PC-POD-CA-007-v03 Revision History Version Reason for Revision Date 01 New POD 30-Sep-13 02 Minor revisions for section 2.3, 3.1, 4.3. 14-April-16

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

Manual of SF6 Comprehensive Tester

Manual of SF6 Comprehensive Tester Manual of SF6 Comprehensive Tester Important Description All the staff taking in charge of the usage or maintenance of this product should carefully read this manual. The same as any other complicated

More information

628 Differential Pressure Decay Leak Tester

628 Differential Pressure Decay Leak Tester 628 Differential Pressure Decay Leak Tester The 628 puts Uson s industry leading differential pressure decay sensitivity in your hands and in your budget with no compromise in quality, reliability, and

More information

FAS-W. Features. Applications. Automatic condensation hygrometer

FAS-W. Features. Applications. Automatic condensation hygrometer FAS-W HUMIDITY ANALYZER Automatic condensation hygrometer the «FAS-W» Moisture Analyzer automatic condensation hygrometer can measure both the volume fraction of moisture and the dew point temperature

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to

More information

krones Sensometic VP and VPL The intelligent probe filler systems

krones Sensometic VP and VPL The intelligent probe filler systems The intelligent probe filler systems Universally applicable With the Sensometic VP and VPL series, Krones offers electronically controlled all-round filler systems for a wide range of products: ll conductive

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide / Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95

More information

SF 6 Product Guide. Gas Analysis Instruments and Accessories

SF 6 Product Guide. Gas Analysis Instruments and Accessories SF 6 Product Guide Gas Analysis Instruments and Accessories Cambridge Sensotec Ltd specialises in the design and manufacture of gas analysis equipment under the Rapidox brand name. Based in the UK, the

More information

POWER IS PRODUCED IN THE HEAD

POWER IS PRODUCED IN THE HEAD english & & The outstanding feature of the V series lances is their round head with its optimized ratio of interior to exterior surface. In conjunction with countersunk aluminum nozzles, the head remains

More information

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap 1250650/6 IM-P125-07 ST Issue 6 MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation

More information

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment) Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium

More information

Technical Data Sheet MF010-O-LC

Technical Data Sheet MF010-O-LC Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the

More information

MANUAL KPS Pressure Control Valve

MANUAL KPS Pressure Control Valve TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006

More information

AUTOMATIC HOSE TEST UNIT, TYPE SPU

AUTOMATIC HOSE TEST UNIT, TYPE SPU VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE

More information

Valve test benches. Systems overview

Valve test benches. Systems overview Valve test benches Systems overview About us In the past few years WIKA has successfully integrated renowned manufacturers of calibration equipment into the group. With these established brands within

More information

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection

More information

BERMAD Waterworks. Combination Air Valve. Air Valves Series. Typical Applications. Features & Benefits. Additional Features.

BERMAD Waterworks. Combination Air Valve. Air Valves Series. Typical Applications. Features & Benefits. Additional Features. BERMA Waterworks Combination Air Valve Model C7 BERMA C7 is a high quality combination air valve for a variety of water networks and operating conditions. It evacuates air during pipeline filling, allows

More information

Constant Pressure Inlet (CCN) Operator Manual

Constant Pressure Inlet (CCN) Operator Manual Constant Pressure Inlet (CCN) Operator Manual DOC-0125 Revision J 2545 Central Avenue Boulder, CO 80301-5727 USA C O P Y R I G H T 2 0 1 1 D R O P L E T M E A S U R E M E N T T E C H N O L O G I E S, I

More information

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards. 1. Scope Description of requirements and procedures for compact provers to be used as verification standards. 2. Reference documents Trade Metrology Act SANS1698 3. Policy A. BASIC REQUIREMENTS Compact

More information

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems Pneumatic Retractable Fittings SensoGate WA 3 Pneumatic retractable fitting for use with Unical 9 and Uniclean 9 automated control systems Easy installation SensoGate WA 3 offers genuine plug & play. The

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Mechanical Pressure Measurement

Mechanical Pressure Measurement Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement

More information

High-speed pressure sensor Model CPT6140

High-speed pressure sensor Model CPT6140 Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications

More information

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

B2KL: 6-way ball valve with male thread, PN 16

B2KL: 6-way ball valve with male thread, PN 16 Product data sheet 3.1 58.001 K: 6-way ball valve with male thread, PN 16 How energy efficiency is improved fficiency means precise control and low actuating forces eatures 6-way ball valve for changeover

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide SHORT DESCRIPTION: 1. Device is applicable to: Burners, Electric boiler, Electric heaters,

More information

11 Air ends 12 Motor 13 Belt driven. 1. ELECTRONIC REGULATION The ES4000 is a control system, designed for medium and high power compressors.

11 Air ends 12 Motor 13 Belt driven. 1. ELECTRONIC REGULATION The ES4000 is a control system, designed for medium and high power compressors. Infinity CSC & CSD Rotary Screw Compressor Range Infinity CSC/CSD compressors are a compact, easy to install range, offering belt or gear driven, fixed or variable speed models. Requiring minimal maintenance,

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a

More information

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications 1800350/6 IM-P180-12 ST Issue 6 BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications Installation and Maintenance Instructions 1. Safety information 2. General

More information

SCIENCE LAB UTILITY CONTROLS

SCIENCE LAB UTILITY CONTROLS SCIENCE LAB UTILITY CONTROLS INCORPORATING GAS PRESSURE PROVING GAS PRESSURE PROVING EQUIPMENT - ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY THE MERLIN RANGE DESIGNED FOR EDUCATIONAL LABORATORIES

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products

More information

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH... 7 66 VGG... VGF... VGH... Gas Valves VGG... VGF... VGH... Single valves of class A for installation in gas trains Safety shutoff valves conforming to EN161 in connection with actuators Suitable for use

More information

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS Wastewater combination air valve in Mod. SCS The air valve guarantees the proper operation of sewage/industrial lines allowing the entrance of large quantity of air in case of pipe bursting or draining,

More information

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100 Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet

More information

RP series Rotor Pumps

RP series Rotor Pumps ontact etails RP series Rotor Pumps Nomenclature Features Low noise Substantial reduction of the operation noise, by to db (comparison with aikin products), and improved sound quality are achieved by adopting

More information

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications GE Sensing & Inspection Technologies 7250 Sys Ruska Multi-Range Pressure Calibration System Features Fully integrated multi-range pressure test and calibration systems Select either an eight range or the

More information

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request Data Sheet: BIT02B.417.R6.EN www.ntt.dk Digital Pressure Gauge COVER on request Bit02B digital gauge series is proposed as the cheaper version of LabDMM but guarantees all the functional characteristics

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

CO2 incubator with additional process controls

CO2 incubator with additional process controls CB series 210 C2 Incubators C2 incubator with additional process controls The BINDER CB series C2 incubator is the premium class among the C2 incubators. It is suitable for all sensitive incubation applications

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size. eries ow to Order opper, fluorine and silicon-free + Low particle generation il ote 1) ote 2) part no. lean series hread type Rc racket assembly ote ) ote 9) 1.0a 0.2a / -20 49-01 49-2-01 ilter regulator

More information

AMT-Ex Dewpoint Transmitter

AMT-Ex Dewpoint Transmitter AMT-Ex Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement

More information

CA14 SG Iron Air and Gas Trap ½" and ¾" (Screwed)

CA14 SG Iron Air and Gas Trap ½ and ¾ (Screwed) ert. No. LRQ 9638 ISO 91 14 SG Iron ir and Gas Trap ½" and ¾" (Screwed) TI-P148-1 ST Issue 6 escription The 14 is a range of float type automatic liquid drainers for air and gas systems. The body and cover

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

Measurement of Low GAS & Liquid Flows

Measurement of Low GAS & Liquid Flows Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300

More information

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount) eries R 2- ow to Order opper, fluorine and silicon-free + Low particle generation il hread type Rc 0 R 03 2 R 03 ody size / ith bracket Round pressure ith set nut tandard specifications odel luid roof

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information