INSTALLATION INSTRUCTIONS FOR FUME SCRUBBERS

Size: px
Start display at page:

Download "INSTALLATION INSTRUCTIONS FOR FUME SCRUBBERS"

Transcription

1 The scrubber and its components are manufactured out of PVC, polypropylene and acrylic. Gaskets are typically EPDM and Viton. Any chemicals fed into the unit, whether as a scrubbing fluid or as fumes being scrubbed, must be compatible with the materials of construction. The fasteners and pump stand are all constructed of stainless steel. It is recommended that any fasteners used during installation also be stainless steel. NOTE: Always dispose of spent scrubber liquid properly. Use proper safety equipment and follow your company s guidelines for handling chemicals during scrubber fluid changes and when performing any work on the unit. Installation and maintenance should always be performed by properly trained personnel. Foundation The unit should be installed upon a completely level and stable foundation using at least every other bolt hole in the octagon base for securing the base to the foundation. These foundation stipulations are requirements should Salco Field Service personnel be commissioned to perform the install. If the foundation is not completely level, it is recommended that the scrubber base be mounted on anchor studs with nuts screwed on in between base and the foundation. These nuts should be adjusted such that the scrubber body is made level. The base should then be shimmed or grouted at all locations where the base does not touch the foundation. This will ensure that the entire base is completely supported. It is critical to shim and grout your foundation to make it conform to the exact shape of the base. The nuts securing the base to the foundation should only be snug. NEVER tighten a nut or bolt to pull the base to fit a foundation! Upon delivery of the scrubber, some warping or creeping of the base may have occurred and should be expected. NOTE: Scrubbers do not substitute or replace vacuum breakers or pressure relief devices. Vacuum breakers and pressure relief devices must be incorporated appropriately as if the scrubber were not present. See note regarding pressure & vacuum relief near the end of this document. Installation 1. Carefully uncrate the unit. 2. Fasten to a suitable foundation taking all precautions described in the above section. 3. If present, remove the protective tape from the fume inlet flange and install the incoming fume piping. Piping plumbed to the fume inlet must not have any low spots. Low spots will flood with fluid. The lowest spot in the piping should be at the fume inlet itself. 4. If present, remove the protective tape from the exhaust flange and bolt on the exhaust stack. If the unit has a blower, an exhaust stack will not be included. Blowers should not be secured to foundations until they have been plumbed to the scrubber lid scrubbers come with an integrated liquid tank. Plumb the recirculation pump & piping according to the CAD prints. Mount the pump adjacent to the scrubber base in a location that facilitates plumbing to and from it and 30 scrubber come with a stand-alone tank. Mount the tank in a location suitable for plumbing to and from it. It is preferred that the tank be mounted closer to the scrubber rather than further away. If desired, the tank may be secured to its mounting location with straps and turnbuckles. Use caution when using straps on insulated tanks. The insulation must not be crushed. Plumb the recirculation pump & piping according to the CAD prints. Mount the pump adjacent to the scrubber base in a location that facilitates plumbing to and from it. NOTE: Check the inside of the liquid tank for debris (plastic shavings, etc.) prior to plumbing it. Rinse out all debris with water. Debris can plug the recirculation pump and/or the shower nozzle. 7. If the unit has a chemical neutralization system, install it according to the CAD prints. Choose a suitable location to mount the dosing pump. See note regarding ph probes at end of this document. Page 1 of 8 Document #: Fume Scrubber Revision 3; 2/27/2014

2 8. If the unit has a manometer, install it according to the following instructions: NOTE: The purpose of the scrubber body manometer is to measure the pressure differential across the bed of packing inside of the scrubber. Manometer Installation onto the Scrubber Body: a. Follow the instructions included with the manometer (#1221) for filling the manometer with the gauge fluid. b. Attach the filled manometer to the two mounting blocks on the scrubber body (See Figure 1) using the supplied #10-24 x stainless steel screws. NOTE: Some assemblies are supplied with #8 x 1/2" titanium screws that can mount directly to the scrubber body. Use these screws if the mounting blocks are not present. c. Apply pipe thread sealant to the threads on the 90 elbow barbs and thread them into the ½ NPT holes which are located on the side of the scrubber body above and below the scrubber packing. Be sure to orient both hose barbs toward the manometer as shown in Figure 2. d. Slip 1 of the hose over one of the manometer ends and cut length to reach the upper hose barb while making sure there are no kinks or flattened sections of hose. e. Place two loose hose clamps on the hose and push the hose onto the barb. f. Tighten one hose clamp on the manometer end and one on the hose barb end. g. Slip the remaining hose over the other manometer end and run the hose to the lower hose barb cutting off any excess and making sure there are no kinks or flattened sections. h. Place the remaining two loose hose clamps on the hose and push the hose onto the barb. i. Tighten one hose clamp on the manometer end and one on the hose barb end. j. Installation is complete. Follow manometer manufacturer s instructions on how to take a gauge reading. Figure 1. Mounting Blocks Figure 2. Manometer Assembly Page 2 of 8 Document #: Fume Scrubber Revision 3; 2/27/2014

3 9. Install all of the electronics that came with the scrubber (conductivity probe, ph probe, conductivity/ph analyzer box, paddle wheel flow meter, paddle wheel flow meter analyzer box, etc.). See the section regarding electronics at the end of this document. Analyzer boxes will be panel-mount unless it was specified by the customer otherwise. NOTE: If using the Rosemount ph probe on a horizontal run, the probe must be installed at least 10 above horizontal. (The body of the probe must make at least a 10 angle with horizontal.) 10. Run power as necessary to the motor(s) and electronics(s). Refer to the manufacturers installation procedures. 11. Fill the scrubber liquid tank 3/4 full with scrubbing liquid. If a chemical neutralization system is present, fill the tank only half-way to start. Experience will dictate proper fill level thereafter. 12. If using a chemical neutralization system, fill your neutralizing chemical storage reservoir with the appropriate neutralization fluid. Be sure the chemical you use is compatible with the scrubber s materials of construction and any other chemicals in the area! Note that the Salco ph analyzer box set up instructions assume that the scrubbed fumes are acidic and that the neutralization fluid is alkaline. 13. See attached instructions for proper programming of the analyzer boxes. For the paddle wheel analyzer boxes, refer to the GF Signet website for set up instructions. 14. Heat trace & insulate the entire scrubber system as necessary. 15. Be sure that the three-way valve on the pump assembly is set to send fluid up to the spray nozzle. 16. Before fumes can be effectively scrubbed, the recirculation pump must be running. This is true even if fumes are note actively being pushed to or pulled through the scrubber (e.g. fumes from simple evaporation of liquid contained in storage tanks). The scrubber will not function properly if the recirculation pump is not on. 17. If the scrubber has a blower, adjust the damper such that the maximum vapor flow rate through the scrubber is not exceeded. Exceeding the maximum vapor flow rate may cause the scrubber column to flood. See table below: Maximum Allowable Vapor Flow Rate Through Scrubber at Recommended Liquid Flow Rates 14" Scrubber 24" Scrubber 30" Scrubber 280 cfm 828 cfm 1293 cfm Before setting the position of the damper, make sure that the vapor flow rate into the scrubber is as high as it ever would be. For example, if the scrubber is being used to treat vapor from multiple sources, identify all of the source(s) that would ever possibly be feeding the scrubber simultaneously. Make sure the blower is free to suck vapor from all of these source(s) prior to the damper being adjusted. To put it another way, assume you have three sources of vapor: A, B and C. Assume that when source A alone is open to the scrubber, it would provide 100 cfm of vapor flow. Assume source B alone would provide 25 cfm and source C would provide 10 cfm. If it s possible that sources A, B and C could all feed the scrubber simultaneously, open all three sources to the scrubber prior to setting the damper position. If it s possible that sources B and C could feed the scrubber simultaneously, but neither B nor C would ever feed the scrubber at the same time as source A, open source A to the scrubber (but leave sources B and C closed) prior to setting the damper position. Flow rates through the scrubber may be inferred using the blower curve and either a manometer mounted at the blower or a vacuum gauge and pressure gauge mounted at the blower inlet and outlet, respectively. These devices may be purchased through Salco if desired. Page 3 of 8 Document #: Fume Scrubber Revision 3; 2/27/2014

4 Operating Requirements Never allow the recirculation pump to run dry or run at a condition below its required net positive suction head. Do not dead-head the pump. If scrubbing HCl with water, the maximum recommended HCl concentration in the recirculating liquid is 4% HCl (by weight). Maximum liquid temperature is 130 F. NOTE: Liquid flow rates must be kept below certain maximums as well or column flooding may occur. These maximum rates cannot be obtained with Salco-supplied pumps provided vapor flow rates are kept at or under their prescribed maximums. If a non-salco supplied pump is used, contact Salco Engineering for maximum recommended flow rate. The minimum liquid pressure at the scrubber spray nozzle should be 5 psig. The below tables list the following information: o Orifice plate hole diameters for 14, 24 and 30 scrubbers (See the section regarding venting of pressurized vessels at the end of this document.) o Scrubber liquid recirculation rates for 14, 24 and 30 scrubbers The listed orifice plate hole size is the diameter that should be used to ensure that the maximum air flow rate through the scrubber is not exceeded when venting pressurized vapor to the scrubber. Exceeding the maximum vapor flow rate could cause flooding in the scrubber column. NOTE: Depending on the emissions requirements of your particular scrubber system, a smaller orifice hole size than what s listed in the table below may be required. The vapor flow rate required to meet your emissions requirements may be less than what s required to prevent the scrubber from flooding. Minimum Square Edged Orifice Plate Hole Diameters (for HCl vapor or dry air at 77 F) Scrubber Inlet Pressure 14" Scrubber 24" Scrubber 30" Scrubber 35 psi 0.90 in 1.60 in 2.00 in 30 psi 0.95 in 1.65 in 2.05 in 20 psi 1.05 in 1.80 in 2.25 in 10 psi 1.20 in 2.05 in 2.60 in Minimum and Recommended Water Recirculation Rates Flow Rate Condition 14" Scrubber 24" Scrubber 30" Scrubber Minimum Flow Rate 8.5 gpm 25 gpm 42 gpm Recommended Flow Rate 10 gpm 32 gpm 54 gpm Page 4 of 8 Document #: Fume Scrubber Revision 3; 2/27/2014

5 Changing/Emptying Scrubber Water 1. The scrubber liquid must be kept clean in order to ensure the scrubber is working efficiently. 2. With either the pump off or while fluid is flowing to the spray nozzle, remove the cam cap from the pump assembly at the three-way valve. 3. Connect hose or piping to the cam adapter. 4. Turn the valve handle to divert flow to the cam adapter. 5. When the liquid tank is almost empty, shut the pump off. DO NOT run the pump dry! It s best to leave a few inches of fluid in the tank to ensure that available suction head does not drop below what the pump requires. 6. For scrubbers with chemical neutralization systems, salt concentration will continually build in the scrubber liquid. Therefore, the scrubber liquid must be changed out periodically to avoid the precipitation of salt crystals onto the scrubber internals. See the section regarding chemical neutralization systems below. Note on chemical neutralization systems Various neutralization options are available for the scrubber system depending on the type of vapor being scrubbed. Take hydrochloric acid vapors for example. You could opt for no neutralization and simply use plain water as the scrubbing liquid. The scrubber liquid tank would be filled with fresh water, and vapors would be scrubbed until acid concentration in the water built up to a certain maximum value (around 4% is common). At that point, the acidized scrubber water must be pumped out and replaced with fresh water. Many people will use this acidized waste water to top off a truck filled with raw acid. Since scrubber liquid volume is much less than the total truck volume, you typically don t end up diluting the raw acid in the truck too much. A chemical neutralization system can also be incorporated. The idea is to consume the scrubbed pollutant via chemical reaction rather than letting it build up in the scrubber liquid. By not allowing the pollutant to build up, scrubbing efficiency is kept high. Note that although the pollutant doesn t build up, other chemical(s) will build up (whatever is produced by reaction of the pollutant with the neutralizing chemical). In the case of hydrochloric acid scrubbing, these products of reaction are typically table salt (sodium chloride) and water. The neutralizing chemical can either be added in a batch fashion each time the scrubbing liquid is replaced or in a continuous fashion. In the case of hydrochloric acid vapor scrubbing, caustic is a common neutralization chemical. If added in a batch fashion, you d add caustic at ~10% concentration to the scrubber liquid tank each time you replaced the fluid. Vapor would be scrubbed until the caustic was entirely consumed. You d typically use ph strips to monitor the amount of caustic remaining. ph probes are not recommended for batch systems. The high starting concentration of the neutralization chemical tends to damage ph probes. A conductivity probe could be used for monitoring, but interpreting the reading requires a little practice. When adding in a continuous fashion, a small dosing pump is used to meter in the neutralization chemical as needed. The pump is automatically cycled on and off according to a ph probe reading. See note regarding ph probes at end of this document. Continuous dosing systems must be monitored closely to ensure that concentration of the products of reaction don t get too high. In the case of reacting hydrochloric acid with caustic, the scrubber liquid must be replaced once salt concentration gets to ~10%. If it s allowed to build up more than that, salt may begin depositing on wetted surfaced inside of the scrubber system (packing, tank, piping, etc). A conductivity meter or hydrometer can be used to monitor salt concentration. Unlike in batch systems, interpreting conductivity meter readings in continuous systems is straight-forward. Page 5 of 8 Document #: Fume Scrubber Revision 3; 2/27/2014

6 Be sure to consider waste liquid disposal implications before deciding whether or not to add a neutralization system. In the case of hydrochloric acid, sodium chloride solution may be easier to dispose of than weak acid. It all depends on what is best for your particular facility. Note on minimum temperature tolerances of electronics Certain electronics common to scrubber systems cannot tolerate extremely low temperatures. Should Salco supply a control panel, it will come with an appropriately-sized panel heater. Otherwise, it is up to the customer to ensure that electronics are kept sufficiently warm. Below are some examples: 1. Paddle wheel flow meters: 0 F (not a concern on heat traced & insulated systems) 2. Paddle wheel flow display boxes: 14 F ( 5 F during storage) 3. Rosemount model ph probes: 14 F (not a concern on heat traced & insulated systems) 4. Rosemount ph/conductivity display boxes: 32 F ( -4 F during storage) 5. ABB model ph probes: 41 F (not a concern on heat traced & insulated systems) 6. ABB model ph/conductivity display boxes: -4 F ( -40 F during storage) Note on use of ph probes You should be aware that ph probes are maintenance-intensive items. Salco supplies a calibration / maintenance kit with each scrubber system in which a ph probe is incorporated. It is the customer s responsibility to ensure that ph probes are maintenanced and recalibrated at necessary intervals. Notes on maintenance of these probes are included in the set up instructions that Salco provides with ph probes. Calibration solutions have finite shelf lives. It is the customer s responsibility to ensure that all calibrations are performed with solutions that have not outlived their shelf lives. Note on power requirements Below are the specific types of electricity that can be used to power common electrical devices: 1. Recirculation pumps for standard-sized scrubbers: low or medium VAC, single-phase 2. Conductivity and ph display boxes: low or medium VAC, single-phase 3. Heat trace circuits and neutralization chemical dosing pumps: medium VAC, single-phase 4. Blowers: medium or high VAC, three-phase 5. Paddle wheel flow meters & ph/conductivity probes require no external power source Note that low voltage refers to V. Medium voltage refers to V, and high voltage refers to V. Page 6 of 8 Document #: Fume Scrubber Revision 3; 2/27/2014

7 Note on spacing/civil requirements The scrubber system as a whole will take up a certain amount of real estate at the installation site. The specific size of this footprint varies from system to system. Before pouring any sort of pad, containment area, etc., it is the customer s responsibility to consult Salco regarding recommended size of said footprint. The scrubber itself, the recirculation pump and the blower (if present) must be installed onto a level concrete pad. Blower assemblies are designed to discharge vapor ~10 ft above the mounting level of the blower. It is the customer s responsibility to support this length of ducting as necessary using guy wires, etc. Note that the scrubbed vapor that flows out of the scrubber will be saturated with water. Should a blower assembly be incorporated, condensation will build up inside this assembly at the lowest point in the assembly (blower & damper). The damper is not water-tight, so built-up condensation will leak out of the damper. The rate at which this leakage occurs is highest just after start-up of the blower. Water-sensitive equipment (like electrical conduit) should not be installed at ground-level in close proximity to the blower or damper. Note on venting of pressurized vessels Often times when a vessel like a truck, railcar, etc., is unloaded using compressed air, some residual pressure remains in the vessel after all of its liquid contents are removed. It is often desirable to vent this excess pressure to the scrubber. This venting is commonly done through an orifice plate mounted at the scrubber vapor inlet. The orifice plate restricts the flow rate of the vapor down below the maximum flow rate that the scrubber is able to handle. In the case of unloading liquid into plastic storage tanks, it is often not best practice to vent this pressurized vapor directly into the storage tank as a means of routing it to the scrubber. Plastic storage tanks often have limited pressure tolerances. Additionally, the flow rate of unthrottled, pressurized vapor through the scrubber may exceed the scrubber s maximum rated vapor flow rate. This can compromise the scrubber s ability to remove pollutants. Upon customer request, Salco can provide the hardware necessary to incorporate an independent vent line that allows vessels to be vented directly to the scrubber (bypassing storage tanks). This independent line is fitted with an orifice plate that automatically throttles vapor feed flow to the scrubber such that scrubbing efficiency is not compromised. This independent vent line can also be incorporated into an automated venting system for pressurized vessels. This system automatically shuts off flow into the storage tank and opens flow into the independent scrubber vent line at the moment all of the liquid has been offloaded from the delivery vessel. Contact Salco for more information. Page 7 of 8 Document #: Fume Scrubber Revision 3; 2/27/2014

8 Note on Pressure / Vacuum Relief Salco-supplied scrubbers are not designed to be used as pressure or vacuum relief devices. Customers who use scrubbers for either of these purposes do so at their own risk. In fact, should a system be incorporated that allows direct venting of fumes to the scrubber (bypassing storage tanks), a check valve would be installed at the scrubber inlet that would prevent the scrubber from providing any vacuum relief to the storage tanks whatsoever Salco recommends that all storage tanks plumbed to scrubbers be fitted with appropriate pressure and vacuum relief valves. Cracking pressures for these valves should correspond to the design specifications of the tanks themselves. Note that storage tanks in general are not rated to tolerate virtually any vacuum. Redundant relief devices, especially in regards to vacuum relief, are always a good idea. Maintenance and Inspection of the Scrubber System Check the scrubber pump operating conditions (vibration, noise) as well as electric current value and discharge pressure and flow rate. When the pump has logged many hours of run time, the front casing screws attaching the pump head to the motor bracket may loosen. Tighten screws periodically while taking care not to deform the plastic parts. Also, after pump has been idled for a long time, tighten screws before pump is used again. Inspect the shower nozzle spray tip for potential clogging and proper spray pattern. Ensure that the packing is clean and not brittle. Check all hoses and tubing for cracking or splitting. Check fittings for leaks and loose connections. Questions? If you have questions regarding this form or any information contained herein, please contact either Dave Hammond ( ) or Geoff Bolak ( ) at Salco Products. Page 8 of 8 Document #: Fume Scrubber Revision 3; 2/27/2014

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL SPECIFICATIONS: The CARD series air valves are available in 3 pipe sizes, 1, 2 and 4 NPT or socket. Maximum inlet pressure

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

O&M Receiving and Inspection. Storage of Water Treatment Media

O&M Receiving and Inspection. Storage of Water Treatment Media O&M 105.1 Receiving and Inspection 1. Equipment should be checked against the Bill of Lading to verify that the number of pieces received matches those shipped. 2. Equipment should be carefully inspected

More information

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

INSTALLATION, OPERATION AND MAINTENANCE GUIDE INSTALLATION, OPERATION AND Placement in Pipeline System When installing Process Development & Control s ElastoTITE Elastomer-Hinged Check Valves in a pipeline, a minimum of five pipe diameters should

More information

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED

More information

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual STOP! Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY

More information

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia - 1-122.6010.6 These instructions describe the installation, operation and maintenance of the subject equipment. Failure

More information

Chemical Injection Technologies Installation/Service Bulletin

Chemical Injection Technologies Installation/Service Bulletin Bulletin 4002 Chemical Injection Technologies Installation/Service Bulletin SUPERIOR Series CL-16/26/56 Automatic Switchover Gas Chlorinator - Installation & Operation IMPORTANT!! READ THESE PRECAUTIONS

More information

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator. RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

ABRASIVE REGULATOR II

ABRASIVE REGULATOR II ABRASIVE REGULATOR II 13096 Abrasive Regulator II TABLE OF CONTENTS Contact Information and Customer & Technical Service... 1 1 Introduction... 1 2 Abrasive Regulator... 1 Description:... 1 2.1 Regulator

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

CentriFlow Meter Integrated Air Entrainment System

CentriFlow Meter Integrated Air Entrainment System CentriFlow Meter Integrated Air Entrainment System INSTALLATION & OPERATION MANUAL January 2004 Revision 021-4 EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website:

More information

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator

More information

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off

More information

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS Procedure-assembly-functional test and performance requirements 1 SCOPE 1.1 This document establishes the general procedure for assembly, functional testing and normal performance requirements of low Series

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Simplex Basket Strainers. To ensure efficient and safe operation of Titan

More information

Installation and commissioning instructions 255 series and 256 series

Installation and commissioning instructions 255 series and 256 series Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

The X-11 Molding Chamber

The X-11 Molding Chamber The User Guide to The X-11 Molding Chamber Table of Contents Overview of Features & Specifications... 3 Features... 4-5 Safety & Maintenance... 6 Initial Startup Procedure... 7 Using the X-11... 8-9 Using

More information

ABRASIVE REGULATOR II

ABRASIVE REGULATOR II ABRASIVE REGULATOR II 13096 Abrasive Regulator II TABLE OF CONTENTS 1 Introduction... 1 2 Abrasive Regulator... 2 2.1 Regulator Installation... 2 Location... 2 Attaching the Regulator to the Machine...

More information

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h) Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h) 100 PPD (2 kg/h) Maximum 250 PPD (5 kg/h) Maximum 500 PPD (10 kg/h) Maximum - 1-122.6006.9 These instructions describe the

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator

More information

APPS-160 Gen 2 User Manual

APPS-160 Gen 2 User Manual APPS-160 Gen 2 User Manual Applicable Products: PN 11914406 - APPS-160 10 to 50 PSIG operating pressure PN 11918618 - APPS-160 40 to 85 PSIG operating pressure Rev 9/16/2004 Chart Ind. www-chart-ind.com

More information

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts

More information

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.

More information

36H SERIES Combination Gas Valve

36H SERIES Combination Gas Valve FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 36H series combination gas valve is

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

BOSS PULISCI PROVA IMPIANTI MEDIA

BOSS PULISCI PROVA IMPIANTI MEDIA BOSS PULISCI PROVA IMPIANTI MEDIA Pump for power flushing operations and removal of impurities, suitable for hydraulic, solar, floor systems and for cooling circuits of medium size. Suitable for buildings,

More information

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES Sampling Valves Installation Commissioning and Operating Instructions SD IL 300 & SD IL 400 Inline Sampling Valve This

More information

Gas Absorption Draft Standard Operating Procedure

Gas Absorption Draft Standard Operating Procedure Gas Absorption Draft Standard Operating Procedure R.C. 9-14 Scope Page 1 Equipment Overview Page 1 Safety Page 2 Operating Procedure Page 4 Equipment Description Page 16 Gas Absorption Experiment Draft

More information

Installation of Your SprayMaster System

Installation of Your SprayMaster System Installation of Your SprayMaster System 1. At the installation site, remove all equipment from the corrugated box and the polyethylene drum and replace the drum lid. Check the picture to identify each

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven 4 IN. BALL LAUNCHER Engine Mounted / PTO Driven OPERATOR S PARTS and MAINTENANCE MANUAL 2006 EDITION BL-MAN-4EN Creation Revision date: 10MAR06 date: by: Ivon LeBlanc by: Table of Contents Table of Contents...

More information

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS STORAGE INSTRUCTIONS Until it is time to install a new or reconditioned valve on the car, the valve must be kept in its original packaging in order to protect it from dirt and damage. INSTALLATION INSTRUCTIONS

More information

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING Contents All Products... Gb-1 Control Valves... Gb-2 Control Valve Actuators... Gb-3 Regulators... Gb-3 Relief Valves... Gb-4 Instruments, Switches, and Accessories... Gb-4 Products Covered by Battery

More information

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems. Page 1 of 7 CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD 1. SCOPE 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems. 1.2 The piping system as used herein is

More information

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS INLET PRESS TAP WTE-RODGERS 36E54-214 DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

Siphon vessel / Priming aid

Siphon vessel / Priming aid Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

Tri-Tech Medical Inc.

Tri-Tech Medical Inc. Introduction Tri-Tech Medical manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS INLET PRESS TAP WTE-RODGERS 36E96-314 DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL

More information

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7 EXEL North America, Inc. EXEL Industrial Canada, Inc. 1310 Washington St 931 Progress Ave., #7 West Chicago, IL 60185 Scarborough ONT, M1G 3V5 Ph : (800) 573 5554 Ph : (800) 450 0655 Fx : (800) 664 1511

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSURE PUMP To minimize vibration, it is best to build brackets on the motor itself, similar to alternator brackets. Use cardboard to construct a pattern first before making

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

Fisher DVI Desuperheater Venturi Inline

Fisher DVI Desuperheater Venturi Inline Instruction Manual DVI Desuperheater Fisher DVI Desuperheater Venturi Inline Contents Introduction... 1 Scope of Manual... 1 Description... 1 Principle of Operation... 2 Installation... 3 Operating Instructions...

More information

PAGE (Rev. A - 06/17)

PAGE (Rev. A - 06/17) Owners Manual Models 4420BF1UDBFR* and 4420BF1LDBFR* Bi-Level Tubular Bottle Filler Fountain with Pet Fountain and Sanitary Freeze Resistant Triple Valve Control Assembly MODEL (LK)4420BF1UDBFR MODEL (LK)4420BF1LDBFR

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

SCA Series Inverted Bucket Steam Traps

SCA Series Inverted Bucket Steam Traps 0770050/5 IM-P077-06 ST Issue 5 SCA Series Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

Flange Bolt Torquing. for Resistoflex Plastic-Lined Piping Products. Torquing. Retorquing. Hydrotesting. Annual retorquing

Flange Bolt Torquing. for Resistoflex Plastic-Lined Piping Products. Torquing. Retorquing. Hydrotesting. Annual retorquing Flange Bolt Torquing for Resistoflex Plastic-Lined Piping Products Torquing When assembling flange connections, always use a full complement of clean, new high strength A193-B7 bolting. If using stainless

More information

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 3000 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator

More information

At the end of this lesson, you will be able to do the following:

At the end of this lesson, you will be able to do the following: Liquid-Phase Contacting Scrubbers Goal To familiarize you with the operation, collection efficiency, and major maintenance problems of liquid-phase contacting scrubbers. Objectives At the end of this lesson,

More information

PRO SINK -R 1 and 2. Dilution system CONTENTS

PRO SINK -R 1 and 2. Dilution system CONTENTS PRO SINK -R 1 and 2 Dilution system CONTENTS 1.0 Product description 2 2.0 Warnings.. 3 3.0 Installation procedure 4 4.0 Plumbing connections 4 5.0 Technical features.. 5 6.0 Maintenance... 6 7.0 Troubleshooting......6

More information

Float Operated Level Controllers

Float Operated Level Controllers CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions

More information

Chlorinator. MODEL C-731 (Floor Mounted)

Chlorinator. MODEL C-731 (Floor Mounted) Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive

More information

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Mooney * Noise Controller Installation, Operation, and Maintenance Manual GE Oil & Gas Mooney * Noise Controller Installation, Operation, and Maintenance Manual imagination at work Scope This manual provides instructions for installation, operation and maintenance of the Mooney

More information

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12) LAKOS Waterworks PWC Series Sand Separators Installation & Operation Manual LS-829 (10/12) Table of Contents Separator Operation... 3 Individual Model Details.... 4 Flow vs. Pressure Loss Chart 4 Installation

More information

Installation Operation Maintenance

Installation Operation Maintenance 682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description

More information

553 Series.

553 Series. 38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual

More information

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000 Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They

More information

Engineering Data Sheet

Engineering Data Sheet Page 1 of 6 CE MARKING AND THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC Valves must be installed into a well designed system and it is recommended that the system be inspected in accordance with the appropriate

More information

Operating Instructions for Cobra and Lynx Duct Leakage Testers

Operating Instructions for Cobra and Lynx Duct Leakage Testers Operating Instructions for Cobra and Lynx Duct Leakage Testers Table of Contents Introduction Introduction... 2 Safety Precautions Safety Precautions.. 2 Prior to Testing System Preparation.. 4 Power Requirements...

More information

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum : FOR OUTDOOR USE ONLY Small Tank LP Kit (STLPK) Installation & Operation Instructions Installation We suggest

More information

Models: C62/63/64-A/D

Models: C62/63/64-A/D Installation & Service C62-991-24A3 Models: C62/63/64-A/D Diaphragm Bypass Pressure Regulating Valves IMPORTANT Record your pump model number and serial number here for easy reference: Model No. Serial

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Model MC Circuit Setter Hose Kits Supply Valve Options: Ball Valve, UBY

Model MC Circuit Setter Hose Kits Supply Valve Options: Ball Valve, UBY Model MC Circuit Setter Hose Kits Supply Valve Options: Ball Valve, UBY Model MC Circuit Setter Description: Circuit Setter Balance Valves are precision engineered valves which function as precise system

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation Accu-Tab Systems 1000 Series by Axiall Corporation Installation and Operating Instructions Model 1050 DANGER: DO NOT MIX CHEMICALS! The Accu-Tab chlorinator is designed for use with Axiall approved tablets

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! INLET PRESS TAP WHITE-RODGERS 36E93-304 Delay-Opening Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

Operating Instructions

Operating Instructions Operating Instructions ProMinent CO2 Feeder CO2 - ProMinent P/N: 7746944 (Revision C), Date 09-14-12 Please completely read through these operating instructions first! Do not discard! The warranty shall

More information

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

KOBOLD KSM FLOWMETER. User Instructions

KOBOLD KSM FLOWMETER. User Instructions KOBOLD KSM FLOWMETER User Instructions USA 1801 Parkway View Drive Pittsburgh, PA 15205 PH 412-788-2830 Canada 9A Aviation Point Claire, QC H9R 4Z2 PH 514-428-8090 www.koboldusa.com KSM_manual_08-10 Table

More information

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1 Serial No. H-V066-E-3 Wafer Check Valve User s Manual Contents (1) Be sure to read the following description of our product warranty 1 (2) General operating instructions 2 (3) General instructions for

More information

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuum-operated, solution-feed gas

More information

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions Before installation these instructions must be fully read and understood Installation and maintenance instructions for Series 93 Positive Pressure Pilot Operated Safety Relief Valves (POSRV). The intent

More information

North American Orifice Metering System

North American Orifice Metering System Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information

Instructions for SILEX 1C Mixed bed cartridge filter

Instructions for SILEX 1C Mixed bed cartridge filter D01B-30A-UK1 January 2017 Instructions for SILEX 1C Mixed bed cartridge filter With conductivity sensor Gravity flow or pressure installation SILHORKO-EUROWATER A/S Phone +45 86 57 12 22 DK-8660 Skanderborg

More information

FRYSAFE COOKING OIL FILTRATION I&O MANUAL

FRYSAFE COOKING OIL FILTRATION I&O MANUAL INSTALLATION OPERATIONS AND MAINTENANCE FRYSAFE COOKING OIL FILTRATION I&O MANUAL 1365 N. Clovis Avenue Fresno, California 93727 1.559.255.1601 www.lakos.com LS-899B (Rev. 12/16) Table of Contents Introduction

More information

Bobtail DOT 407 / 412 Vacuum

Bobtail DOT 407 / 412 Vacuum PROCO INCORPORATED AUGER OPERATION Manual Bobtail DOT 407 / 412 Vacuum Vacuum Tank Operation This vacuum tank has been built for Dot work. Extreme care must be exercised regarding product handling. The

More information

Glove Box Installation Manual

Glove Box Installation Manual Glove Box Installation Manual 1998 by M. Braun Company File: GB-UNI-INS.DOC! Edition 08-00 by M. Boutin! Subject to be changed without notice Glovebox Installation Your Glove box has been fully assembled,

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

Atmospheric relief valve type 1100 Installation and maintenance instructions

Atmospheric relief valve type 1100 Installation and maintenance instructions SAPAG 1. Description Sapag atmospheric relief valves type 1100 have been selected for installation because of their performance features, reliability and ease of maintenance. They are designed to protect

More information

Accu-Tab Systems 2000 P Series by Axiall Corporation

Accu-Tab Systems 2000 P Series by Axiall Corporation Accu-Tab Systems 2000 P Series by Axiall Corporation Installation and Operating Instructions Models 2075 P 2150 P For NSF/ANSI-Standard 61 NSF STANDARD 61 applications use NSF/ANSI Standard 60 listed Axiall

More information

MANUAL. Sesame. Thermoplastic Tank Technologies

MANUAL. Sesame. Thermoplastic Tank Technologies MANUAL Sesame Thermoplastic Tank Technologies INSTALLATION AND USER GUIDE CONTENT 1. GENERAL 3 2. IMPORTANT 3 3. INSTALLATION EXPANSION VESSEL 4 4. USE EXPANSION VESSEL 5 5. AIR CELL REPLACEMENT 5 5.1

More information

SIMPLAIR PIPING TOOL. JXT Company

SIMPLAIR PIPING TOOL. JXT Company SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The Acid-Rite ph Adjustment System is designed for use with Axiall

More information