THE LOWER BODY NEGATIVE PRESSURE (LBNP)

Size: px
Start display at page:

Download "THE LOWER BODY NEGATIVE PRESSURE (LBNP)"

Transcription

1 TECHNICAL NOTE Design of a Chamber for Lower Body Negative Pressure with Controlled Onset Rate Jonny Hisdal, Karin Toska, and Lars Walløe HISDAL J, TOSKA K, WALLØE L. Design of a chamber for lower body negative pressure with controlled onset rate. Aviat Space Environ Med 2003; 74: We have designed a lower body negative pressure (LBNP) chamber and control system that makes it possible to apply LBNP either very rapidly ( 300 ms), or more gradually, according to predefined protocols. The capability of the new, high-performance agile aircraft to reach a high-g onset rate makes it highly desirable to be able to study immediate, rapid, and transient cardiovascular responses to simulated gravitational stress. Our new LBNP chamber has been used to study the main cardiovascular variables during onset and release of mild LBNP ( 20 mmhg). We have revealed large transient physiological responses during the onset and release of mild LBNP. This new finding was largely made possible by precise control of the onset and release of LBNP during the experiments. The purpose of this paper is therefore to describe some of the technical solutions which made rapid and controlled changes in LBNP possible, focusing on the importance of precise control of the LBNP chamber. Keywords: lower body negative pressure, methods, cardiopulmonary baroreceptors, arterial baroreceptors. THE LOWER BODY NEGATIVE PRESSURE (LBNP) technique was introduced to study circulatory responses to simulated gravitational shifts of blood in humans. The LBNP technique was first described in 1965 by Stevens and Lamb (3). Despite frequent use of the technique in physiological investigations during the last few decades, the time course of the onset and release of LBNP and the transient cardiovascular responses to this stress have seldom been discussed. New high-performance agile aircraft can reach high-g levels in less than a second. Since aircrew regularly experience the rapid onset of acceleration exposure and there is a possibility of rapid transitions between zero and negative or positive G forces, research tools such as human centrifuges and LBNP chambers must also meet more stringent technical requirements. More knowledge of the time course, dynamics, and mechanisms of cardiovascular responses is now needed. This must be obtained through studies of cardiovascular responses and mechanisms, using continuous recordings of the cardiovascular variables. The sampling frequency must be high enough to observe transient changes (i.e., within a heartbeat) in the cardiovascular variables recorded. Both cardiopulmonary and arterial baroreceptors must be studied. We have designed a LBNP chamber and control system that makes it possible to apply LBNP either very rapidly ( 300 ms) or more gradually, according to predefined protocols. Studies using the new chamber have revealed large transient physiological responses during the onset and release of mild LBNP (1,2). This new finding was largely made possible by precise control of the onset and release of LBNP during the experiments. Since little has been published about the design of LBNP chambers, we spent a great deal of time and money on designing and developing optimal solutions for the LBNP chamber. The present paper therefore has two aims. The first is to share information on the design of our LBNP chamber. We hope this will be helpful for colleagues who intend to build or improve LBNP chambers. The second aim is to focus on the importance of precise control of the LBNP chamber, not only during the steady state parts of experiments but also during the onset and release of LBNP. METHODS Fig. 1 shows the LBNP chamber and the bench. The main parts of the device are a tube of sufficient size to accommodate the lower body, a reservoir tank (117 L) to allow rapid release of pressure, and a mobile bench with an airtight waist seal and a regulated vacuum source. The tube is made of transparent polymethylmethacrylate (PMMA), length 1250 mm, inner diameter 480 mm, outer diameter 500 mm. A vacuum cleaner (Mièle S251 i, Mièle, Inc., Princeton, NJ) with adjustable effect from W is used to generate sub-atmospheric pressure in the reservoir tank. Vacuum cleaners generate greater air flow and are far cheaper than comparable commercial vacuum pumps. From the Department of Physiology, Institute of Basic Medical Sciences, University of Oslo, Norway (J. Hisdal, L. Walløe); and the Royal Norwegian Air Force, Institute of Aviation Medicine, Oslo, Norway (K. Toska). This manuscript was received for review in January It was revised in January It was accepted for publication in February Address reprint requests to: Jonny Hisdal, M.Sc., who is a researcher, Department of Physiology, Institute of Basic Medical Sciences, University of Oslo, P.O Box 1103 Blindern, N-0317 Oslo, Norway; jonny.hisdal@basalmed.uio.no. Reprint & Copyright by Aerospace Medical Association, Alexandria, VA. 874 Aviation, Space, and Environmental Medicine Vol. 74, No. 8 August 2003

2 Design of the Waist Seal For precise regulation of the pressure in the chamber, it is very important to avoid air leaks between the waist of the test subject and the waist seal. The design of the waist seal appears to have caused problems for many researchers. In 1971, Wolthuis et al. (5) published one solution to this problem. For the chamber descriped in our paper, a rigid PMMA board (thickness 20.0 mm) was cut to fit the test subject s waist (Fig. 2). Pipe foam (the type used to insulate water pipes) was split lengthwise and laid on the rigid board to cushion the subject s back and make the waist seal airtight. This type of foam is available in a range of thicknesses and can be adjusted to the size of the subject. In addition to pipe foam, test subjects wore a neoprene skirt that fit smoothly around the hips. The skirt may be custommade, but commercial skirts used for kayaking are also suitable and are available in various sizes. We used commercial neoprene kayaking skirts in our study (sizes S, M, and L; Wild Water, Bolton, UK). Fig. 1. The LBNP chamber, with the foot end of the mobile bench on the left side of the photograph. The bench has an adjustable footboard (1). (A saddle could also be used so that the subject s legs are suspended and serve as a fluid reservoir.) To guide the LBNP chamber into the right position, a small wheel (2) that fits the rail at the bottom of the tube is mounted on the end of the bench. A reservoir tank (3) is connected to the transparent PMMA tube (4). A large-diameter hose connects the reservoir tank and the tube (5). Sub-atmospheric pressure is generated in the tank and the tube by a vacuum cleaner that is insulated and enclosed in the box beside the tank (6). The chamber may be operated from the control box (7) or by digital signals generated from pre-programmed profiles stored in a computer. The PMAA tube lies in a soft rubber cradle (8). Getting In and Out of the Chamber Both the bench and the LBNP chamber are wheeled. Once the bench has been placed in the predetermined position, the wheels are locked, and the test subject can lie down on the bench. The chamber then slides along the bench so that it encloses the test subject s lower body (see Fig. 2). A small wheel is mounted on the end of the bench (see Fig. 1). This wheel fits into a rail that is glued to the bottom of the tube to guide the LBNP chamber easily in and out in the correct position. The end wall that closes the tube is divided into two (see Fig. 2). This construction makes it possible first to place the test subject on the bench and then to move the LBNP chamber to surround the lower body. Rapid Onset and Release of LBNP Large volumes of air must be removed from the LBNP chamber to reduce the pressure to given levels below room pressure. At least for pressures lower than around 10 mmhg below room pressure, it is difficult or impossible to reduce the pressure very rapidly and precisely using only a vacuum pump. A reservoir tank must be connected to the LBNP chamber via large diameter hoses (Ø 75 mm), so that large volumes of air can be removed from the chamber in a short time period. Rapid-action valves, controlled by electrical solenoids, are the best way of opening and closing the connection between the reservoir tank and the tube. Full opening of the valves must be achieved as quickly as possible to ensure rapid air flow between the reservoir tank and the tube. We used custom-built valves. The electrical solenoids control the valves are from Isliker Magnete (Andelfingen, Switzerland). We used GE-50 to control the valve at the tank, GE-70 to control the valve between the tank and the tube, and GE-60 in the valve on the back plate of the LBNP chamber (Fig. 1). For slower profiles, pressure in the tube may be regulated by changes in the power of the vacuum pump, or by adjusting the airflow into the LBNP chamber by means of a spring valve controlled by an electrical step engine instead of rapid opening and closure of solenoid-controlled valves. To ensure that the valve has a short response time, it is important to use a valve flap Fig. 2. Details of the waist seal. The end wall that closes the tube is divided into two. The lower part is permanently mounted on the bench (1). The upper part (2) is added after the LBNP chamber is placed around the lower body, and is held in the right position by two rubber straps (3). Pipe foam is split lengthwise and laid on the rigid board to cushion the subject s back and make the waist seal airtight (4). This type of foam is available in different thicknesses and can be adjusted to the size of the subject. Test subjects also wore a neoprene skirt that fit smoothly around the hips. Both the test subject and the test leader can operate emergency controls that open valves and shut down the vacuum pump. The test subject is holding the emergency control in her right hand (5). Aviation, Space, and Environmental Medicine Vol. 74, No. 8 August

3 of low mass. We regulated the chamber pressure by regulating the force of the valve spring by an electrical step engine (STP-42ND48SVE-50, Epson Electronics, San Jose, CA). A micro controller (PIC16C84, Microchip Technology, Westford, MA) was used to control the step engine. These solutions make it possible to induce linear changes in pressure. Results from a study using gradual onset and release of LBNP are presented in Hisdal et al. (1). Control of the Chamber Pressure inside the chamber is controlled either by regulating the power of the pump and thereby the amount of air removed from the tube, or by reducing the controlled air flow into the tube through the valves connected to the tube. Pressure sensors continuously monitor pressure inside the tube and the tank. We used pressure sensors from Lucas Novasensor (NPC D, Fremont, CA). The pressure sensors must give an analog output signal that can be sampled during the experiments, and it must also be possible to control and calibrate them before use. During the tests, analog electrical signals are sent to a computer, where the pressure is recorded. Air leakage during the experiments is not normally a problem if the waist seal described above is used. If it is difficult to maintain a stable pressure in the chamber, one solution is to add a micro controller that compares the measured pressure with the set point. If there is a difference, the controller can be programmed to send signals to the valves or the vacuum pump to modulate chamber pressure and reduce the difference. Onset and Release of LBNP The onset and release of LBNP are controlled by a computer program, which sends digital signals from the computer to the control system (PIC16C73A, Microchip Technology). We used a DOS-based program (REGIST) developed by Morten Eriksen in our group. Any commercial program that has the ability to send out digital signals can be used. The onset and release of LBNP may be programmed to occur at specified times during an experiment, e.g., 120 s after the start of the experiment. Alternatively, if the aim is to apply LBNP within a diastole of a defined heartbeat, its onset and release may be triggered by defined R-waves in the ECG signal (Fig. 3). Noise during Operation of the Chamber Acoustic noise is produced during operation of the LBNP chamber, since large volumes of air are moved through small openings or valves. This noise may have physiological effects on the test subjects and must therefore be reduced as much as possible. One solution is to equip the test subjects with ear protectors. Another is to install the air intake of the pump in an adjacent room. The acoustic noise from the pump engine may be sufficiently reduced by proper insulation of the engine (Fig. 1). Another option is to install the pump in a Fig. 3. The upper panels (A) of the figure show ECG and LBNP during one experiment. Sample frequency is 50 Hz for both variables. Onset and release are triggered by R-waves in defined heartbeats. The black arrows in the upper and lower panels indicate the R-wave that triggers the onset of LBNP. The lower panels (B) show details of the onset of LBNP. In the recording shown, the control system is programmed to activate the onset of LBNP during the first heart beat detected s after the start of the recording. The onset of LBNP is programmed to be delayed for 300 ms after detection of the R-wave, and is then applied within ms. This ensures that LBNP is applied during the diastole of the first heart beat detected after t s. soundproof enclosure and move it away from the LBNP stand to reduce noise and vibration. (The pump or vacuum cleaner produces a lot of heat during operation.) Thermal Effects on the Test Subjects The evacuation of air from the LBNP chamber increases the cooling of the test subject s lower body. This happens even at a relatively high ambient temperature. The additional cooling may have an influence on the variables recorded. It is especially important to be aware of the cooling problem in studies where acral skin blood flow or skin temperature is recorded. This is a difficult problem to deal with, since some air flow through the chamber is needed to maintain a stable pressure. The best solution is probably to insulate the test subject s lower body sufficiently to prevent cooling. In our lab we have used custom-made thermal boots. See Vissing et al. (4) for one example of how additional cooling may affect results obtained in studies using the LBNP technique. To reduce the problem, the tube can be constructed so the airflow is routed under the table. 876 Aviation, Space, and Environmental Medicine Vol. 74, No. 8 August 2003

4 Safety Precautions The chamber is designed and tested to operate at pressures from mmhg below room pressure. The PMAA tube lies in a soft rubber cradle, and is held in the right position by its own weight. No holes are drilled in the PMMA tube, since this would introduce unpredictable weak points. The weakest point in our construction is at the ends of the tube. With an LBNP of 100 mmhg, the safety factor is calculated to be approximately 100. However, every laboratory should carry out individual calculations based on the dimensions and material of the tube used. Both the test subject (see Fig. 2) and the test leader can operate emergency controls that open the valves and shut down the vacuum pump. A manually operated emergency valve ( spring controlled ) is adjusted to open if pressure drops below the set level. All valves are designed to open if electrical power is lost. The design of the waist seal makes it easy to evacuate a test subject from the LBNP chamber if an emergency should occur. RESULTS Studies using our LBNP chamber have revealed transient physiological responses during the onset and release of mild LBNP. Our most important findings have been made in studies designed to test the hypothesis that there may be transient effects on mean arterial pressure (MAP) during the onset and release of mild LBNP that are not observed in the steady state parts of protocols using mild LBNP (1,2). Fig. 4 shows the responses of stroke volume (SV), heart rate (HR), cardiac output (CO), and mean arterial pressure (MAP) to the rapid onset and release of mild ( 20 mmhg) LBNP maintained for 300 s. This demonstrates that there are significant transient effects on SV, HR, CO, and MAP during the onset and release of LBNP that are not observed during the steady state period. DISCUSSION Mild LBNP is often defined as LBNP between 0 and 20 mmhg. It is defined as mild since it has been found not to have any significant effect on MAP. Mild LBNP has therefore been used as a method of inducing a significant reduction in central venous pressure (CVP) without affecting MAP. The idea has been that only cardiopulmonary baroreceptors are affected by the fall in CVP, while arterial baroreceptors are not stimulated, since MAP is found to be unchanged. Furthermore, any physiological response or lack of response observed has been related to isolated stimulation of the cardiopulmonary baroreceptors. We have demonstrated that this is incorrect, and that MAP is affected during both rapid (2) and gradual onset of mild LBNP (1). Fig. 4 shows that MAP is at the same level during the steady state part of the protocol as before and after the application of mild LBNP. Precise and uniform application and release of LBNP, in addition to continuous recording of the cardiovascular variables in all tests, made it possible to observe that there are physiologically very important Fig. 4. Averaged stroke volume (SV), heart rate (HR), cardiac output (CO), and mean arterial pressure (MAP) for 16 test subjects before, after, and during 20 mmhg LBNP. Several transient effects on the recorded variables are observed. There is a marked asymmetry in the response of SV and CO to the onset and release of LBNP. SV takes about s to stabilize after application of LBNP, whereas it is normalized in s after release of LBNP. There is also a significant drop in SV during the first heartbeats after release of LBNP. The most important finding illustrated in this figure is that there are significant changes in MAP both during onset and release of LBNP. This indicates that not only cardiopulmonary but also arterial baroreceptors are stimulated. More details of the study from which these data are taken have been published in Hisdal et al. (2). transient effects on MAP during the onset and release of mild LBNP. To allow proper comparisons of the results of studies using this technique, descriptions of the LBNP chambers used need to be more detailed than has generally been the case. During the steady state, information on how precisely the chamber pressure is controlled should be given, e.g., 1 mmhg. Finally, it is particularly important to specify the rate of onset and release of LBNP. This is probably also of importance when studying steady state and transient responses to higher levels of LBNP. Our studies and the example above show how important it is to control pressure in the LBNP chamber precisely when using the technique. In projects where the aim is to study the influence of baroreceptor responses on various cardiovascular variables, precise control of the pressure is essential. If the onset and release of LBNP is imprecise or variable, important transient physiological responses may be impossible to Aviation, Space, and Environmental Medicine Vol. 74, No. 8 August

5 detect, and in the worst case the results may be interpreted incorrectly and the wrong conclusions drawn. Additional construction details and more pictures of our LBNP chamber can be provided by the authors on request. ACKNOWLEDGMENTS The Norwegian Council on Cardiovascular Diseases funded the construction of the LBNP chamber. We are grateful to Morten Eriksen for writing the computer program used to sample the cardiovascular parameters. We would also like to thank A. Sira, Ø. Løkeberg, and E. Salberg for technical assistance with the design and construction of the LBNP chamber. REFERENCES 1. Hisdal J, Toska K, Flatebø T, Walløe L. Onset of mild lower body negative pressure (LBNP) induces transient change in mean arterial pressure (MAP) in humans. Eur J Appl Physiol 2002; 87(3): Hisdal J, Toska K, Walloe L. Beat-to-beat cardiovascular responses to rapid, low-level LBNP in humans. Am J Physiol Regul Integr Comp Physiol 200l; 281:R Stevens PM, Lamb LE. Effects of lower body negative pressure on the cardiovascular system. Am J Cardiol 1965; 16: Vissing SF, Scherrer U, Victor RG. Increase of sympathetic discharge to skeletal muscle but not to skin during mild lower body negative pressure in humans. J Physiol 1994; 481(Pt 1): Wolthuis RA, Hoffler GW, Baker JT. Improved waist seal design for use with lower body negative pressure (LBNP) devices. Aerosp Med 1971; 42: Aviation, Space, and Environmental Medicine Vol. 74, No. 8 August 2003

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual EMISSION CHAMBERS Bulk and Surface Emission Detection for the RAD7 User Manual TABLE OF CONTENTS INTRODUCTION 3 1 SYSTEM CONFIGURATION 4 1.1 Closed Loop Configuration 4 Fig. 1 Emission Chamber Closed Loop

More information

Level MEASUREMENT 1/2016

Level MEASUREMENT 1/2016 Level MEASUREMENT 1/2016 AGENDA 2 A. Introduction B. Float method C. Displacer method D. Hydrostatic pressure method E. Capacitance method G. Ultrasonic method H. Radar method I. Laser method J. Level

More information

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications GE Sensing & Inspection Technologies 7250 Sys Ruska Multi-Range Pressure Calibration System Features Fully integrated multi-range pressure test and calibration systems Select either an eight range or the

More information

MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS

MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS 24 TH July 2013 MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS Vern Costelow Business Development Consultant AWMA Water Control Solutions INTRODUCTION Surface irrigation is still

More information

GROUTEC SCOTT VICKERS. Grouting Equipment

GROUTEC SCOTT VICKERS. Grouting Equipment GROUTEC SCOTT VICKERS Grouting Equipment SCOTT VICKERS manufacturers a range of cement and chemical grouting equipment including:- PUMPS - The Cement Grout Pumps are all diaphragm-type. These diaphragms,

More information

MIL-STD-883G METHOD

MIL-STD-883G METHOD STEADY-STATE LIFE 1. PURPOSE. The steady-state life test is performed for the purpose of demonstrating the quality or reliability of devices subjected to the specified conditions over an extended time

More information

RESIDENTIAL WATER DISTRIBUTION

RESIDENTIAL WATER DISTRIBUTION RESIDENTIAL WATER DISTRIBUTION This case study demonstrates the steady-state simulation of the fresh water (drinking water) reticulation system in a small village. WATER RETICULATION Page1 WATER RETICULATION

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

The latest automotive systems require innovative leak test methods and fixturing.

The latest automotive systems require innovative leak test methods and fixturing. Leak Testing Auto Parts The latest automotive systems require innovative leak test methods and fixturing. In the past, automobile manufacturers only required basic forms of leak testing to check standard

More information

STANDARD PROCEDURE OF A TIGHTNESS TEST OF A SOLAR COLLECTOR BOX. (EUROSUN 2000 SOLAR CONGRESS)

STANDARD PROCEDURE OF A TIGHTNESS TEST OF A SOLAR COLLECTOR BOX. (EUROSUN 2000 SOLAR CONGRESS) STANDARD PROCEDURE OF A TIGHTNESS TEST OF A SOLAR COLLECTOR BOX. (EUROSUN 2000 SOLAR CONGRESS) Ole Holck and Svend Svendsen Department of Buildings and Energy, Technical University of Denmark Building

More information

AN ANALYSIS ON HIGH PRESSURE DYNAMIC CALIBRATORS USED IN THE DEFENSE AREAS

AN ANALYSIS ON HIGH PRESSURE DYNAMIC CALIBRATORS USED IN THE DEFENSE AREAS AN ANALYSIS ON HIGH PRESSURE DYNAMIC CALIBRATORS USED IN THE DEFENSE AREAS Sung Soo HongPresenter Agency for Defense Development, Taean, 357-942, South Korea sungsoo@add.re.kr Abstract Up to now, there

More information

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1)

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1) Modeling and Field Verification Study of Air Slam Conditions on kalanit Pipeline System By Yiftach Brunner & Sathish Kumar ir valves are integral part of long water transmission mains and are essential

More information

This test shall be carried out on all vehicles equipped with open type traction batteries.

This test shall be carried out on all vehicles equipped with open type traction batteries. 5.4. Determination of hydrogen emissions page 1 RESS-6-15 5.4.1. This test shall be carried out on all vehicles equipped with open type traction batteries. 5.4.2. The test shall be conducted following

More information

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM

More information

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION IFU SBPMON107 CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE BATTERY INSTALLATION CORRECT POSITION FOR MEASUREMENT POSITIONING THE CUFF

More information

CASE STUDY. Elvington To Brayton Barff Air valve replacement Program

CASE STUDY. Elvington To Brayton Barff Air valve replacement Program CASE STUDY Elvington To Brayton Barff Air valve replacement Program Vent-O-Mat Anti-Shock Air valves have helped Yorkshire Water reduce maintenance costs, reduces surge and improve flows in their trunk

More information

Measuring range Δp (span = 100%) Pa

Measuring range Δp (span = 100%) Pa 4.4/ RLE 5: Volume-flow controller, continuous How energy efficiency is improved Enables demand-led volume flow control for the optimisation of energy consumption in ventilation systems. Areas of application

More information

Noninvasive Blood Pressure Measurement. D. J. McMahon rev cewood

Noninvasive Blood Pressure Measurement. D. J. McMahon rev cewood Noninvasive Blood Pressure Measurement D. J. McMahon 141018 rev cewood 2017-10-23 Key Points Noninvasive Blood Pressure Measurement: - ways to measure pressure, direct mechanical measurement: Bourdon Tube

More information

Drilling Efficiency Utilizing Coriolis Flow Technology

Drilling Efficiency Utilizing Coriolis Flow Technology Session 12: Drilling Efficiency Utilizing Coriolis Flow Technology Clement Cabanayan Emerson Process Management Abstract Continuous, accurate and reliable measurement of drilling fluid volumes and densities

More information

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017 Procedure Instruction of program Explosion Pressure - Test Round 2017 Content 1 General Performance... 2 2 Measurand / Characteristic of interest... 2 3 Test Item and Configurations... 2 3.1 Components...

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!#$% IA1B. Model IA1B INSTRUCTION MANUAL Automatic Blood Pressure Monitor with Fit Cuff =Fit Cuff=!"#$% Model IA1B Contents Introduction... 2 Notes on Safety... 3 Know Your Unit... 5 Quick Reference Guide... 7 Initial

More information

Teacher s Assistant Laboratory Guide

Teacher s Assistant Laboratory Guide Teacher s Assistant Laboratory Guide Joseph B. Hakanson 1, Warner Meeks 2, and Dr. Joshua L. Rovey 3 Missouri University of Science and Technology, Rolla, Missouri, 65409 These instructions will discuss

More information

CORESTA RECOMMENDED METHOD N 6

CORESTA RECOMMENDED METHOD N 6 CORESTA RECOMMENDED METHOD N 6 DETERMINATION OF VENTILATION DEFINITIONS AND MEASUREMENT PRINCIPLES (2015 Revision September 2016) 1. SCOPE This CORESTA Recommended Method specifies a method for the determination

More information

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB Vacuum egulator eries -IV/ How to Order tandard connections IV C08 traight Clean series ody size Max. flow 140 L/min (N) Max. flow 240 L/min (N) L Fittings traight Connection tubing O.D. ymbol ubing O.D.

More information

- From 2005 year model, replacing with RM250 with 2-stroke engine, RM-Z450 with 4-stroke engine was introduced in the market. - From 2008 year model,

- From 2005 year model, replacing with RM250 with 2-stroke engine, RM-Z450 with 4-stroke engine was introduced in the market. - From 2008 year model, 1 - From 2005 year model, replacing with RM250 with 2-stroke engine, RM-Z450 with 4-stroke engine was introduced in the market. - From 2008 year model, fuel injection system was introduced instead of carburetor

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Acoustic Emission Testing of The Shell 0f Electromagnetic Valve guozhen XU 1, yiwei CHEN 1, zhihua CAO 2 ABSTRACT Shanghai

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

Monitoring Gas Pressure in Vacuum Insulation Panels

Monitoring Gas Pressure in Vacuum Insulation Panels Gas Pressure in VIP Monitoring Gas Pressure in Vacuum Insulation Panels Dr. Roland Caps, va-q-tec AG, Karl-Ferdinand-Braun-Str. 7, D-978 Würzburg, Germany, www.va-qtec.com, caps@va-q-tec.com, Hermann Beyrichen,

More information

Training for Proofmaster M/S/Automat. Functional principle for airtightness testing

Training for Proofmaster M/S/Automat. Functional principle for airtightness testing Training for Proofmaster M/S/Automat Functional principle for airtightness testing July 2017 Airtightness measurement 1. Measuring principle 2. Behaviour of the watch under vacuum 3. Behaviour of the watch

More information

Aerodynamic Measures for the Vortex-induced Vibration of π-shape Composite Girder in Cable-stayed Bridge

Aerodynamic Measures for the Vortex-induced Vibration of π-shape Composite Girder in Cable-stayed Bridge Aerodynamic Measures for the Vortex-induced Vibration of π-shape Composite Girder in Cable-stayed Bridge *Feng Wang 1), Jialing Song 2), Tuo Wu 3), and Muxiong Wei 4) 1), 2, 3), 4) Highway School, Chang

More information

INTEGRITY, SAFETY AND EFFICIENCY IN LNG TRANSFER IMPACT OF EMERGENCY SHUTDOWN AND RELEASE OPERATIONS

INTEGRITY, SAFETY AND EFFICIENCY IN LNG TRANSFER IMPACT OF EMERGENCY SHUTDOWN AND RELEASE OPERATIONS INTEGRITY, SAFETY AND EFFICIENCY IN LNG TRANSFER IMPACT OF EMERGENCY SHUTDOWN AND RELEASE OPERATIONS Evert van Bokhorst Frank Driessen Erik Nennie David Remans Jan Smeulers TNO Technical Sciences Delft,

More information

TEST SPECIFICATION NYT-909-C

TEST SPECIFICATION NYT-909-C 748 Starbuck Ave, Watertown, NY 13601 Phone: +1-315-786-5200 Engineering Fax: +1-315-786-5673 TEST SPECIFICATION NYT-909-C CODE OF TESTS FOR TESTING "AB" TEST RACK P/N 702546 & 702612 ISSUE NO. 5 1.0 THE

More information

Mitos Fluika Pressure and Vacuum Pumps Datasheet

Mitos Fluika Pressure and Vacuum Pumps Datasheet Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Dolomite

More information

Standard Operating Manual

Standard Operating Manual Standard Operating Manual Allwin21 AW610 RTP Page 1 of 18 Contents 1 Picture and Location 2 Process Capabilities 2.1 Cleanliness Standard 2.2 Recipes 2.3 Performance of Allwin21 AW610 RTP 3 Contact List

More information

VACCUPERM Vacuum chlorine gas dosing systems

VACCUPERM Vacuum chlorine gas dosing systems VACCUPERM Vacuum chlorine gas dosing systems Vaccuperm, precise and safe dosing. www.clorep.es VACCUPERM INTRODUCTION Vaccuperm provides a proven and reliable technology of vacuum gas dosing. Handling,

More information

VINAYAK PHARMA TECHNOLOGY

VINAYAK PHARMA TECHNOLOGY Page 1 Page 2 GENERAL DESCRIPTION Vinayak, Glove Leak Tester is designed for testing integrity of gloves and its sealing with glove port used in various applications. The Gloves are leak tested under the

More information

Specifications for the CMI 2409 Magnetocardiograph

Specifications for the CMI 2409 Magnetocardiograph Specifications for the CMI 2409 Magnetocardiograph Revision date April 14, 2006 1 518-381-1000 (tel) The CMI-2409 system consists of a holder (A), a patient bed (B) and a workstation (not shown in the

More information

ELEVATION CORRECTION FACTORS FOR RADON MONITORS*

ELEVATION CORRECTION FACTORS FOR RADON MONITORS* ELEVATION CORRECTION FACTORS FOR E-PERM@ RADON MONITORS* P. Kotrappa and L. R. Stiefl Abstract-E-PERMm radon monitors are based on the principle of electret ion chambers and are usually calibrated in a

More information

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Test pumps. Pressure sources. Good reasons for proper and reliable calibration Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even

More information

Series Environmental Chambers

Series Environmental Chambers 3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instruction and Maintenance Manual GRYF OXY ZM 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 www.gryf.eu ver.: 11.2.2015 OEM module

More information

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller CHEMICAL ENGINEERING LABORATORY CHEG 239W Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller Objective The experiment involves tuning a commercial process controller for temperature

More information

PROPOSAL OF FLUID SELF-EXCITED OSCILLATION PECULIAR TO A FLAT RING TUBE AND ITS APPLICATION

PROPOSAL OF FLUID SELF-EXCITED OSCILLATION PECULIAR TO A FLAT RING TUBE AND ITS APPLICATION PROPOSAL OF FLUID SELF-EXCITED OSCILLATION PECULIAR TO A FLAT RING TUBE AND ITS APPLICATION Hideyuki Tsukagoshi 1, Ato Kitagawa, Keisuke Tambo, and Hiyoyuki Chiba ABSTRACT A novel fluid power actuator

More information

Fluid Flow. Link. Flow» P 1 P 2 Figure 1. Flow Model

Fluid Flow. Link. Flow» P 1 P 2 Figure 1. Flow Model Fluid Flow Equipment: Water reservoir, output tubes of various dimensions (length, diameter), beaker, electronic scale for each table. Computer and Logger Pro software. Lots of ice.temperature probe on

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

Experimental Study of Water Hammer Pressure in a Commercial Pipe

Experimental Study of Water Hammer Pressure in a Commercial Pipe IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) Experimental Study of Water Hammer Pressure in a Commercial Pipe Ashish Kumar Patel 1 1 (School of Mechanical Engineering, Lovely Professional

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Technical Data Sheet MF010-O-LC

Technical Data Sheet MF010-O-LC Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the

More information

MODELLING OF FUME EXTRACTORS C. R.

MODELLING OF FUME EXTRACTORS C. R. LD8 19th International Symposium of Ballistics, 7 11 May 21, Interlaken, Switzerland MODELLING OF FUME EXTRACTORS C. R. Woodley WS4 Guns and Warheads Department, Defence Evaluation and Research Agency,

More information

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Lab 1c Isentropic Blow-down Process and Discharge Coefficient 058:080 Experimental Engineering Lab 1c Isentropic Blow-down Process and Discharge Coefficient OBJECTIVES - To study the transient discharge of a rigid pressurized tank; To determine the discharge coefficients

More information

Akasison Flow phenomena of a siphonic roof outlet

Akasison Flow phenomena of a siphonic roof outlet Akasison Flow phenomena of a siphonic roof outlet Ir. Marc Buitenhuis MTD Hydraulic research engineer Akatherm BV, Panningen, The Netherlands 06-01-2011 Abstract So far the investigations on siphonic roof

More information

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK ABSTRACT Ventilation stacks are becoming increasingly common in the design of naturally

More information

Barrier Development and Evaluation Methodology. D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA

Barrier Development and Evaluation Methodology. D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA Barrier Development and Evaluation Methodology D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA 1. Introduction: Vacuum insulation is now a rapidly expanding market and technical advances are being

More information

ASSE International Product (Seal) Listing Program

ASSE International Product (Seal) Listing Program ASSE International Product (Seal) Listing Program ASSE 1070-2015 / ASME A112.1070-2015 / CSA B125.70-15 Performance Requirements for Water Temperature Limiting Devices Manufacturer: Contact Person: E-mail:

More information

H 2. Sensor Series Take no risk! Install a Hydrogen Sensor in your Gaschromatograph

H 2. Sensor Series Take no risk! Install a Hydrogen Sensor in your Gaschromatograph Sensor Series 9000 Take no risk! Install a Hydrogen Sensor in your Gaschromatograph Carrier Gases for GC Probably more than 90% of the present GC instruments run with helium as carrier gas. Some people

More information

Quick Installation Guide Doc nr.: C Date:

Quick Installation Guide Doc nr.: C Date: Quick Installation Guide Doc nr.: 9.17.093C Date: 13-05-2016 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or

More information

Tightening Evaluation of New 400A Size Metal Gasket

Tightening Evaluation of New 400A Size Metal Gasket Proceedings of the 8th International Conference on Innovation & Management 307 Tightening Evaluation of New 400A Size Metal Gasket Moch. Agus Choiron 1, Shigeyuki Haruyama 2, Ken Kaminishi 3 1 Doctoral

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

Sartorius CCL kg Prototype Mass Comparator

Sartorius CCL kg Prototype Mass Comparator Sartorius CCL1007 1 kg Prototype Mass Comparator For Dissemination of the Mass Scale and Calibration of Weights Sartorius has developed a unique mass comparator with the Bureau International des Poids

More information

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR Model HEM-412C TABLE OF CONTENTS Introduction 3 Know Your Unit 4 Quick Reference Guide 5 Battery Installation/Replacement 6 How To Apply The Arm

More information

Improving distillation tower operation

Improving distillation tower operation Improving distillation tower operation Measuring differential pressure across long sections of distillation columns has always been challenging, but purpose-built sensor systems provide a solution Fast

More information

BLOOD PRESSURE SENSOR BT17i USER S GUIDE

BLOOD PRESSURE SENSOR BT17i USER S GUIDE BLOOD PRESSURE SENSOR BT17i USER S GUIDE CENTRE FOR MICROCOMPUTER APPLICATIONS http://www.cma-science.nl Short description The Blood Pressure sensor BT17i allows measuring arterial blood pressure. The

More information

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10 TS1 Ultrasonic Tank Sender Installation and Operating Instructions For TS1 Firmware v3.8 Page 1 Table of Contents 1. FEATURES... 3 2. SPECIFICATIONS... 3 3. DIMENSIONS... 4 4. MOUNTING AND INSTALLATION...

More information

Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers

Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers Journal of Physics: Conference Series PAPER OPEN ACCESS Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers Related content - The versatile use

More information

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S06* Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Recirculating Coolers

Recirculating Coolers (Chillers) - Basic type Low Temp. - General Type Low Temp. - Intelligent type Selection Guide Recirculating Cooler Basic type General type (Low temp.) Intelligent type (Low temp.) Working Temp. Range (

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S02 Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Barcol-Air BRM Radiant Module

Barcol-Air BRM Radiant Module Barcol-Air BRM Radiant Module General The high capacity Radiant Cooling Module BRM is based on the principles of the radiant cooling technology. Due to the purpose designed profile and the geometry of

More information

Service Test Unit for ROSS Proportional Valves RESK

Service Test Unit for ROSS Proportional Valves RESK Service Unit for Proportional Valves Page 1 Technical Description ROSS 04.08.2015 Service Test Unit for ROSS Proportional Valves Technical Description V 1.0 / 2015 RESK 4591.40 For all Prop Valve Models

More information

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual Sensor for Air Bubble Detection at Liquid Filled Tubes SONOCHECK Type ABD06.xx Operating Manual Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Air Bubble Detector ABD06.xx SONOTEC Ultraschallsensorik

More information

Continuously Variable Inertance Tubes for Pulse Tube Refrigerators

Continuously Variable Inertance Tubes for Pulse Tube Refrigerators Continuously Variable Inertance Tubes for Pulse Tube Refrigerators J.M. Pfotenhauer 1, T. Steiner 1, L.M. Qiu 2 1 University of Wisconsin Madison, Madison, WI 53706 2 Zhejiang University, Hangzhou, 310027

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

Testing of Active Flow Control actuators at harsh environment

Testing of Active Flow Control actuators at harsh environment Testing of Active Flow Control actuators at harsh environment Ionut BRINZA (INCAS) 6 th CEAS CONFERENCE 16-20 October 2017 Bucharest ROMANIA Introduction Results of the harsh environment tests Conclusions

More information

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING Blair Chalpin Charles A. Matthews Mechanical Design Engineer Product Support Manager Scanivalve Corp Scanivalve Corp Liberty Lake, WA

More information

Pressure transmitters EMP 2

Pressure transmitters EMP 2 Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,

More information

AIR PRESSURE CONTROLLED MASS MEASUREMENT SYSTEM

AIR PRESSURE CONTROLLED MASS MEASUREMENT SYSTEM Measurement of Mass, Force and Torque (APMF 2013) International Journal of Modern Physics: Conference Series Vol. 24 (2013) 1360002 (6 pages) The Authors DOI: 10.1142/S2010194513600021 AIR PRESSURE CONTROLLED

More information

ENS-200 Energy saving trainer

ENS-200 Energy saving trainer ENS-200 Energy saving trainer Find out about the essential aspects of energy efficiency in compressed air installations Save money Put it into practice Take care of the environment Get training www.smctraining.com

More information

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

Analysis of Pressure Rise During Internal Arc Faults in Switchgear Analysis of Pressure Rise During Internal Arc Faults in Switchgear ASANUMA, Gaku ONCHI, Toshiyuki TOYAMA, Kentaro ABSTRACT Switchgear include devices that play an important role in operations such as electric

More information

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV Vacuum egulator IV0/ eries oh AJ A45 ingle ided Connections eries AX For ease of installation and panel mounting AM AM Integrated digital pressure switch for panel mounting I -A I (Made to Order) ingle

More information

PROTOTYPE DEVELOPMENT FOR A LEAK-PREVENTIVE TOILET FLUSH SYSTEM AN MET SENIOR DESIGN (CAPSTONE) PROJECT

PROTOTYPE DEVELOPMENT FOR A LEAK-PREVENTIVE TOILET FLUSH SYSTEM AN MET SENIOR DESIGN (CAPSTONE) PROJECT Session 3548 PROTOTYPE DEVELOPMENT FOR A LEAK-PREVENTIVE TOILET FLUSH SYSTEM AN MET SENIOR DESIGN (CAPSTONE) PROJECT Cheng Y Lin, PhD, PE Department of Engineering Technology Old Dominion University Norfolk,

More information

AMS 6916 Board mount pressure sensor with ratiometric analog output

AMS 6916 Board mount pressure sensor with ratiometric analog output FEATURES Piezoresistive pressure sensor with amplified analog output Calibrated and temperature compensated Ratiometric voltage output, 0.5 4.5 V Digital signal conditioning, 12 bit output resolution Differential,

More information

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler C. Becnel, J. Lagrone, and K. Kelly Mezzo Technologies Baton Rouge, LA USA 70806 ABSTRACT The Missile Defense Agency has supported a research

More information

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards. 1. Scope Description of requirements and procedures for compact provers to be used as verification standards. 2. Reference documents Trade Metrology Act SANS1698 3. Policy A. BASIC REQUIREMENTS Compact

More information

Vehicle-mounted meters, pump supplied

Vehicle-mounted meters, pump supplied Purpose This inspection procedure outline (IPO) defines the minimum tests which must be performed to ensure that basic volumetric measuring devices comply with the legislation. Application Vehicle-mounted

More information

Load Responsive Multilayer Insulation Performance Testing

Load Responsive Multilayer Insulation Performance Testing Load Responsive Multilayer Insulation Performance Testing S. Dye 1, A. Kopelove 1, and G. L. Mills 2 1 Quest Thermal Group, 6452 Fig Street Suite A, Arvada, CO 80004 USA 2 Ball Aerospace & Technologies

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties Quick Installation Guide Doc nr.: 9.17.052H Date: 10-12-2015 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or

More information

Pump On Demand. Skimmer System

Pump On Demand. Skimmer System Pump On Demand Skimmer System POD (Pump on Demand) Skimmer System Application Out-of-the-box LNAPL recovery in 2-inch and larger-diameter wells. The POD Skimmer model TR-610 recovers light-end hydrocarbons

More information

AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET

AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET AC 2007-1108: ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET Matthew Braley, University of Idaho Paul Anderson, University of Idaho Tracey Windley, University of Idaho Kevin Buck, University

More information

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED] Lecture 19 PRESSURE-CONTROL VLVES [CONTINUED] 1.5 Counterbalance Valve Schematic diagram of counterbalance valve is shown in Fig. 1.14. These normally closed valves are primarily used to maintain a back

More information

Modeling of Hydraulic Hose Paths

Modeling of Hydraulic Hose Paths Mechanical Engineering Conference Presentations, Papers, and Proceedings Mechanical Engineering 9-2002 Modeling of Hydraulic Hose Paths Kurt A. Chipperfield Iowa State University Judy M. Vance Iowa State

More information

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION Exercise 2-2 Second-Order Interacting Processes EXERCISE OBJECTIVE Familiarize yourself with second-order interacting processes and experiment with the finer points of controller tuning to gain a deeper

More information

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation Standard Operating Procedure # Chemical Fume Hood Operation Facility: NMSU College of Engineering Laboratories Written by: Juanita Miller, Safety Specialist, miljgh@nmsu.edu (575)-646-1292 Scope: This

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

The API states the following about tube rupture for a shell-and-tube heat exchangers:

The API states the following about tube rupture for a shell-and-tube heat exchangers: Tutorial This tutorial describes the theory and modeling process of a tube rupture event using the special element type Rupture element in BOSfluids. It covers the algorithm BOSfluids uses to model the

More information

Tutorial. BOSfluids. Relief valve

Tutorial. BOSfluids. Relief valve Tutorial Relief valve The Relief valve tutorial describes the theory and modeling process of a pressure relief valve or safety valve. It covers the algorithm BOSfluids uses to model the valve and a worked

More information

VALVES HIDROMATIC VALVE.

VALVES HIDROMATIC VALVE. VALVES HIDROMATIC VALVE Hydrodynamic design The Hidromatic valve of Hidroconta is a piston hydraulic valve controlled with the same fluid of the conduction. Its balloon design improves its hydrodynamic

More information