LPG LEVEL GAUGE /INDICATOR manual
|
|
- Leon Jefferson
- 6 years ago
- Views:
Transcription
1 LPG LEVEL GAUGE /INDICATOR manual All Rights Reserved. Copying the text, pictures, nameplates before prior permission is forbidden. FHT Production: FHT Export-Import, Minsk Mazowiecki, Szczecinska 16G Street. FHT Foreign Trade Office info: , fax: Enquiries at
2 The installation of VERSUS Gauge should be done according to the following scheme: 1) In most cases optimal position of the Gauge towards Multivalve is as on the picture: NOTE: THE MOST IMPORTANT IN VERSUS GAUGE CALLIBRATION IS TO SELECT PROPER POSITION OF THE GAUGE TOWARDS THE MULTIVALVE AND TO FIT THE INDICATOR SOLIDLY. The back side of the indicator have to be the closest to the MV (not far than 0,5 mm). If it is fitted in other way the indicator could not show every level of LPG inside the tank.
3 In most cases optimal position of the gauge is in the range between (pictures below): Not suggested positions (pictures below): INCORRECT! If the gauge is incorrectly fitted to the Multivalve the indication of LPG inside the tank could be different tan real level or proportionally different.
4 There are 5 diodes on the indicator. One of them shines on red (low level of LPG in the tank). The rest of them indicate the level of LPG in the tank (green color). To set up proper indication of LPG level inside the tank you it is recommended: a) firstly to fill the tank with about ¼ real capacity. Real capacity means that if nominal capacity is 50 liters the tank can be filled only with 40 liters of LPG (20% of air safety area inside the tank). b) So in case of 50 liters capacity tank you have to fill the tank with 10 (1/4 of 40 liters = 10 liters) liters of LPG. Than; c) It is essential to set up proper indication on the gauge. The indication on that is as follows: Note: ONLY ONE OF THE DIODES SHINES. d) If the tank was filled with ¼ real capacity (in our case 50 ltr nominal capacity = 40 ltr real capacity. ¼ = 10 ltr) first step is to turn the indicator on the gauge to set up initially proper indication. There is no rule if you are to turn the indicator right or left. You have to turn the indicator till the moment the second diode starts to shine (first green diode from the diagram above). e) Next stem is to screw the indicator to the Multivalve (two screws from both sides of the indicator).
5 f) If there is 10 ltr of LPG inside of 50 ltr nominal capacity the tank and the indicator was properly fitted to Multivalve on VERSUS change over switch inside driver cabin you can see red diode shining (not blinking, not any green diode shining). g) If there is any difference in the indication between VERSUS change over switch and VERSUS LPG Gauge you can set up proper indication in the software (described in further part of this manual). BEFORE THAT PLEASE MAKE SURE THE INDICATOR IS PROPERLY CONNECTED TO THE MULTIVAVLE (POSITION, SOLIDNESS). h) Than what should be done is to fill up the tank in full. In our case (50 ltr nominal capacity LPG tank it should be 10 ltr + 30 ltr = total 40 ltr). If LPG Tank is full the indicator fitted to Multivalve should show Full tank diode shining. On VERSUS change over switch you could see all of the diodes shining. If there is any difference in the indication you should set up adequate parameter in VERSUS software in LPG level sensor bookmark: NOTE: the changes should be performed when the car works on LPG. i) VERSUS software automatically set up VERSUS/AEB1050 sensor. Please check if you selected right sensor (should be as on the picture above in case of VERSUS LPG gauge). Than if the indication is not real you have the possibility to change it. In case of Full tank you should operate the value responsible for 1/1 (picture below).
6 There is no rule if you should decrease the value of to increase. In our case initial value of that is 241. If the diode 1/1 does not shine but the tank is full you have to increase or decrease the parameter in the window responsible for that indication till the moment the indication is proper (all diodes of VERSUS change over switch shines). NOTE: AFTER ANY CHANGE IN THE VALUE IN THE WINDOWS RESPONSIBLE FOR INDICATION YOU HAVE TO PRESS WRITE TO DEVICE. j) You can set up the value for ½, ¾ in the same way on the basis of the same rules. Note: if you intend to set up the parameter responsible for ¾th indication there should be ¾ LPG inside the tank. There are some reasons for improper indication: 1) the construction of Multivalve itself. Sometimes in case of 50 ltr nominal capacity the tank can be filled with 45 ltr (sometimes 37 ltr etc.). Also how many liters of LPG can be put inside the tank depends on LPG filling station pump pressure (some differences between different countries standards/allowed pressure). 2) The indication is based on some magnetic rules. Multivalve (E67R 01 ) has a coil. Coil generates electromagnetic field that can disturb proper work of any LPG gauge. EXAMINIG PROPER WORK OF THE INDICATOR. Therefore sometimes it is essential to set up proper indication in the software. To examine if the gauge works correct (if it is not broken) you should: 1) connect wiring to the indicator (+, - is to be connected) 2) to use Multivalve (recommended) or piece of magnet and to put it close to back side of the indicator. 3) Than to move the arm of Multivalve/magnet slowly. 4) If the gauge works correct EVERY DIODE SEPARATELY shines. All Rights Reserved. Copying the text, pictures, nameplates before prior permission is forbidden. FHT Production: FHT Export-Import, Minsk Mazowiecki, Szczecinska 16G Street. FHT Foreign Trade Office info: , fax: Inquiries at info@versuslpg.com.
Job Sheet 1. Geothermal Energy
Job Sheet 1 Geothermal Energy OBJECTIVES In this job sheet, you will become familiar with the training system components. You will operate your training system in heating and cooling mode and observe the
More informationOPERATION MANUAL NTF-15
OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE
More informationOPERATION MANUAL NTF-60 Plus
OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)
More informationAutomatic Twin Greasing System
Parts Manual Automatic Twin Greasing System YOUR EFFICIENCY IS OUR CHALLENGE All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm or
More informationunconventional-airsoft.com
unconventional-airsoft.com Congratulations on your new digital fire control computer! This unit will change the way you use and look at your electric gun. With this short document, you will know all you
More informationCover Page for Lab Report Group Portion. Head Losses in Pipes
Cover Page for Lab Report Group Portion Head Losses in Pipes Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 February 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section
More informationReverse Osmosis System Installation Guide and Operation Manual.
Reverse Osmosis System Installation Guide and Operation Manual. Table of Contents 1 Introduction...2 2 Installation...3 2.1 Feed water connection...3 2.2 Permeate and concentrate plumbing...3 2.3 Electrical
More informationUNIVERSITY OF WATERLOO
UNIVERSITY OF WATERLOO Department of Chemical Engineering ChE 524 Process Control Laboratory Instruction Manual January, 2001 Revised: May, 2009 1 Experiment # 2 - Double Pipe Heat Exchanger Experimental
More informationProMaster Troubleshooting Guide
ProMaster Troubleshooting Guide Always read your owner's manual before operating or doing maintenance on your ProMaster marker. The manual contains in-depth maintenance and setup information. Always remove
More informationCopyright Velocomp LLP 2006
ibike Pro Cadence Handlebar Mount Owners Manual January 2007 1 Table of Contents Installing the ibike Pro cadence mount on your bicycle Installing the ibike Pro cadence mount on your time trial bike Installing
More informationOperating Manual Body fat balance
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating Manual Body fat balance KERN MFB Version
More informationInoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.
Inoxair Repair Manual Edition: 12/2010 Content 1) Serial number 2) Technical data 3) Functional principle 4) Problem analysis 5) Removal 6) Repairs 7) Circuit diagram and cable-connection-plan 8) Pneumatic
More informationMAINTENANCE AND OPERATING MANUAL
MAINTENANCE AND OPERATING MANUAL Cyclone condensate separator Type ASA EN EN Maintenance and operating manual Purpose and appropriate use Dear Customer, thank you for choosing our product. In order to
More informationDrift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer
Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer M. F. Vineyard, T. J. Carroll, and M. N. Lack Department of Physics University of Richmond, VA 23173 ABSTRACT The
More informationUSER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM
USER MANUAL OPERATION AND THE USE OF A CAR WITH Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM Page 2 / 8 Table of csontents 1. STARTING THE ENGINE... 3 2. CONTROL PANEL... 3 2.1 Indication of the current
More informationMAGNETIC CYCLING TRAINER SF-B0419 USER MANUAL
MAGNETIC CYCLING TRAINER SF-B049 USER MANUAL IMPORTANT: Read all instructions carefully before using this product. Retain owner s manual for future reference. For customer service, please contact: support@sunnyhealthfitness.com
More informationMoveRoll Conveyor Operating and Maintenance Manual
MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.
More informationWire ropes condition monitoring: conception and embodiment
NDT2015, Hyderabad November 26-28, 2015 More info about this article: http://www.ndt.net/?id=21134 Wire ropes condition monitoring: conception and embodiment Alexander Mironenko INTRON PLUS LTD., Moscow,
More informationPOWER LIFT LOW PRESSURE LIFTING BAGS. Instructions for use
POWER LIFT LOW PRESSURE LIFTING BAGS Instructions for use The system of WEBER-HYDRAULIK low pressure lifting bags of the 0.5 and 1.0 bar series is used particularly for rescuing persons captured in various
More informationAUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP
USER MANUEL AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP TIRE EQUIPMENT MANUFACTURER 1.866.409.RACK WWW.MARTINSINDUSTRIES.COM info@martinsindustries.com PARTS Verify that the following components
More informationMP15 Jockey Pump Controller
Setup and Operating Instructions MP15 Jockey Pump Controller This manual provides general information, installation, operation, maintenance, and system setup information for Metron Model MP15 Jockey Pump
More informationA little technical and safety...
A little technical and safety... Please familiarise yourself with the contents of this booklet as it references the safety of your tank installation and safe supply of LPG. Please also keep to hand a note
More informationTroubleshooting Guide Aquarius
Low Access Pressure Access pressure has dropped below the lower alarm limit of 0 to - 250mmHg Blood pump is off Blood flow is too low Turn blood pump on Check blood flow rate. Consider increasing the blood
More informationOC Panel High Limit Aquastat Kit, Manual Reset p/n
OC Panel High Limit Aquastat Kit, Manual Reset p/n 233202 Instruction Sheet APPLICATION The OC (Option Control) Panel High Limit Aquastat Kit provides electronic temperature sensing in a UL limit-rated
More informationProcess Control Loops
In this section, you will learn about how control components and control algorithms are integrated to create a process control system. Because in some processes many variables must be controlled, and each
More informationFour common PRESSURE CALIBRATION PAIN POINTS
Four common PRESSURE CALIBRATION PAIN POINTS Pressure calibration is often critical to process control systems, helping to optimize operations and ensure plant safety. While pressure instrumentation can
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationUBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions
Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM
More informationThe Discussion of this exercise covers the following points:
Exercise 4-1 Float Switches EXERCISE OBJECTIVE In this exercise, you will study the construction and operation of a magnetic reed float switch. You will use a float switch to limit the amount of liquid
More informationInstallation and commissioning instructions 255 series and 256 series
Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...
More informationSCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties
Quick Installation Guide Doc nr.: 9.17.052H Date: 10-12-2015 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or
More informationUser Manual. Low Shear Viscometer LS 300. prorheo GmbH Bahnhofstr. 40/ Althengstett Tel
User Manual Low Shear Viscometer LS 300 prorheo GmbH Bahnhofstr. 40/2 75382 Althengstett Tel. +49-7051-92489-0 Office@proRheo.de www.prorheo.de 1. Introduction... 3 1.1. Measuring system... 3 1.2. Principle
More informationParts Manual. Frusheez Machines
Parts Manual Frusheez Machines Model No. 1414 and 1416 Model 1414 Model 1416 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA Part No. 110007 ORDERING SPARE PARTS 1. Identify the needed part by checking
More informationSWS Option: Well Pressures. SWS Option: Stretch Correction (Corrected depth) SWS Option: MMD (Magnetic Marks Detection) ASEP Products
SWS Option: Well Pressures PART NUMBER L-8531039779 The SmartMonitor can simultaneously measure, display and record depth and up to four different well pressures (for example, Control Line Pressure, Tubing
More informationGas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.
Quality Products at Competitive Prices Gas Check Automatic testing of the down-stream installation to check that all valves are closed and that pipework and fittings are gas tight before each system start-up.
More informationAquavar SOLO 2 Frequently Asked Questions
Aquavar SOLO 2 Frequently Asked Questions How do I size the Aquavar SOLO 2 for the appropriate pump/motor combination? Can I use a 208 Volt motor? Can I run the Aquavar SOLO 2 up to 80HZ? What are the
More informationPart IV: Troubleshooting
Part IV: Troubleshooting Excessive Oil Carryover Pump-Up Time Test Excessive oil carryover can have adverse effects on the performance of pneumatic climate control systems. Although some oil entrainment
More informationAir Ball! Evaluation copy
Air Ball! Computer 24 Do you ever wonder how the National Basketball Association (NBA) decides how much air should be in the basketballs used during a game? The NBA measures the pressure inside the ball
More informationMODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR
MODEL NUMBER: 45043-450P-A AUTOMATIC PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and
More informationTESTING AT VERY LOW FLOWRATE
TESTING AT VERY LOW FLOWRATE Author : Valérie Leprince (PLEIAQ) for BCCA npo August 2018 Buildings are becoming tighter and tighter, leading to test at very small flowrate compared to the volume of the
More informationWPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE
PACIFIC LIQUID & AIR SYSTEMS WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE IN THE BEGINNING Before installing or operating this system, familiarize yourself with these instructions. You should
More informationCode Basic module and level control complete with optionals code
AUTOMATION AND PROCESS CONTROL MPCT - Modular Process Control Trainer Code 916960 Basic module and level control complete with optionals code 916961-916962-916963-916964-916965 1. General Didacta proposes
More informationQuick Installation Guide Doc nr.: C Date:
Quick Installation Guide Doc nr.: 9.17.093C Date: 13-05-2016 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or
More informationSAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .
User Manual Capacitance Continuous Level Indicator Comprehensive User s Manual. Introduction. General Description. Principle of Operation. Specifications. Connection Diagrams. Quick Calibration Chart.
More informationECL Comfort 110, application 131 (valid as of software version 2.00)
Operating Guide ECL Comfort 110, application 131 (valid as of software version 2.00) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /
More informationEXPERIMENT XI. Careful!! Improper handling of the vacuum line may result in the release of SO 2 which is an irritating and suffocating gas.
Chem 366-3 Page XI - 1 EXPERIMENT XI INFRARED SPECTRUM OF SO2 (S&G, 5th ed. Expt 36, 6th ed. Expt. 35) 1. Pre-Lab preparation. The description of this experiment has disappeared from the more recent editions
More informationNote: You will need a full tank of CO2 for connection and leak testing! Kit Number
Owners Manual Design Engineering Inc. CryO2 Cryogenic Tank Installation Kit To be used with CryO2 components only! Persons experienced in the installation and proper operation of Performance systems like
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationDeclining Weight Blending System Quick Start Manual E Main St Marshall, IL Phone: Fax: Website:
Declining Weight Blending System Quick Start Manual 12285 E Main St Marshall, IL 62441 Phone: 217-826-6352 Fax: 217-826-8551 Website: www.yargus.com P a g e 2 MAIN SCREEN The MAIN SCREEN on the cover page
More information450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES
EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS
More informationSALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS
STORAGE INSTRUCTIONS Until it is time to install a new or reconditioned valve on the car, the valve must be kept in its original packaging in order to protect it from dirt and damage. INSTALLATION INSTRUCTIONS
More informationPneumatics for Newbies Designing a Pneumatic Solution
Pneumatics for Newbies Designing a Pneumatic Solution FIRST Robotics Team 358, Hauppauge, NY Introduction Pneumatics is using air to push/pull things. The pistons and tubing are light and powerful, lighter
More informationArmfield Distillation Column Operation Guidelines
Armfield Distillation Column Operation Guidelines 11-2016 R.Cox Safety SAFETY GLASSES ARE REQUIRED WHEN OPERATING THE DISTILLATION COLUMN Wear gloves when mixing alcohol feedstock The column will become
More informationUSER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73
USER MANUAL Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * *) Require software ID: DID-SW-001 1/73 Table of contents 1 General... 3 1.1
More informationOperating Instructions Part No
DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0545 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationEasy Nest Kits. Installation Suggestions
Easy Nest Kits Installation Suggestions 2 General Recommendations Hydraulics Vacuum breakers should be installed to prevent siphoning. Flexible connectors should follow FRP tank manufacturers recommendations.
More informationNTF-230 OPERATION MANUAL
NTF-230 OPERATION MANUAL MAHLE Aftermarket Inc., Service Solutions 10 Innovation Drive York, Pennsylvania 17402 USA Phone: 717-840-0678 Toll Free: 800-468-2321 Web-site: www.servicesolutions.mahle.com
More informationDischarge Relief Valve Operation & Maint.
Relief Valve Operation & Maint. CZ Series Centrifugal Fire Relief svalve Operation and Maintenance Instructions 1410 Operation and Maintenance Form No. F-1031 Section 2302.6 2111 Issue Date 04/90 11/95
More informationUser Manual for the Mars Calibration Bench
User Manual for the Mars Calibration Bench Fall 2013 Table of Contents Table of Contents Table of Contents... iii Introduction... v Chapter 1: The Mars Calibration Bench... 1 What Is the Mars Calibration
More informationOPERATION OF LIQUID PARTICLE COUNTER. GP-B P0045 Rev -
1 W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission OPERATION OF LIQUID PARTICLE COUNTER GP-B P0045 Rev - May 23, 1997
More informationCover Page for Lab Report Group Portion. Pump Performance
Cover Page for Lab Report Group Portion Pump Performance Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 March 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number:
More informationFurther technical information is available on
1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,
More informationACI_Release_Notes.txt VERSION Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION
VERSION 2.4.0 1. Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION 2.3.9 1. Fixed Dive Computer configuration section error 2. Fixed message for download/upload
More informationP7810A-D Pressuretrol Controller
P780A-D Pressuretrol Controller P780C, D P780A, B FEATURES PRODUCT DATA Use only with steam, air or noncombustible gases that do not corrode the pressure sensing element. Models available with on-off control
More informationG96 Series BASOTROL Dual Operator Valve
Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without
More information9A5N Solid State CW Paddle
9A5N Solid State CW Paddle User manual Table of contents: 1. General description 2. Before you begin 3. Finger piece and/or battery installation 4. Interconnection 5. Lever(s) sensitivity adjustment 6.
More informationNIV EAU MATIC ST User Manual Made in Canada
NIV EAU MATIC ST User Manual Made in Canada www.niveaumatic.com info@niveaumatic.com -2- Table of contents Introduction Section 1 Page 4 Installation Section 2 Pages 5 to 10 2.1 Control box 2.2 Sensor
More informationElevator Concepts ltd. by Wurtec Krause Riverview, MI Fax:
Hydraulic System Set-up Ver. 1 4/22/13 18720 Krause Riverview, MI 48193 734.246.4700 Fax: 734.246.2547 www.elevatorconcepts.com ADJUSTMENTS HYDRAULIC SYSTEM SETUP BLAIN EV10 & EV100 ¾ VALVE Refer to Blain
More informationThe Discussion of this exercise covers the following points:
Exercise 5-3 Wet Reference Leg EXERCISE OBJECTIVE Learn to measure the level in a vessel using a wet reference leg. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Measuring
More informationAnnual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5
Page 1 of 5 Vessel Name: Serial number MCU: Serial Number EPU: Serial Number Skid: Mains Supply: V AC @ Hz Software version MCU: Software version EPU: K-factor Cell: K-factor Skid Flowmeter: P/L Maximum
More informationH.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9
H.T.S.T. EQUIPMENT TEST PROCEDURES Field Reference Sequence of Testing Equipment testing should be conducted in the following sequence to minimize equipment run times. Pasteurizer Not Operating 3, 1, 4,
More informationINSTALLATION MANUAL JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. Before installation. Installation INSTALLATION MANUAL: B700
Thank you for purchasing this product. Please read this installation manual before assembling and using the product, and be sure to use the product properly. An accident or injury can result if the product
More informationG92 Series BASOTROL Automatic Pilot Gas Valve
Installation Instructions Issue Date September 17, 2008 G92 Series BASOTROL Automatic Pilot Gas Valve Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These
More informationOperation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve
Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve Model CYCLE GARD II, CI & CNA YOUR PRODUCT INFORMATION: Model Number: Date: Serial Number:
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationExercise 3-2. Two-Wire and Three-Wire Controls EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Two-wire control
Exercise 3-2 Two-Wire and Three-Wire Controls EXERCISE OBJECTIVE Construct two-wire and three-wire control circuits and understand their principles. DISCUSSION OUTLINE The Discussion of this exercise covers
More informationAQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents
AQUARIUS Operating Instructions for the Type 70 Electrolytic Gas Soldering / Welding Unit Table of Contents 1. Important General Remarks 2 2. Safety Instructions 2 3. Description of the Soldering Unit
More informationNEULOG OXYGEN LOGGER SENSOR GUIDE
NeuLog oxygen logger sensor NUL-205 The oxygen sensor can be used for any science experiment or activity where oxygen levels, dissolved or gaseous, are required. Some fields of study include Chemistry,
More informationMODEL NUMBER: P PORTABLE COMPRESSOR
MODEL NUMBER: 30033-300P PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product.
More informationExperiment C-6 Gas Solubility
1 Experiment C-6 Gas Solubility Objectives To measure dissolved oxygen in water by using an oxygen sensor. To learn about physical factors that influence oxygen solubility in water. To examine the dissolved
More informationMapping a Magnetic Field. Evaluation copy. Figure 1: Detecting the magnetic field around a bar magnet
Mapping a Magnetic Field Experiment 16 The region around a magnet where magnetic forces can be detected is called a magnetic field. All magnets, no matter what their shape, have two poles labeled north
More informationInstallation Instructions Air Compressor Part # 2780, 2781
Note: It is essential that the operator of this product read and understand the contents of this manual before installing and using this product. Parts Included Qty Parts Included Qty Compressor 1 Coil
More informationAdditel761 Series Firmware Updates
Additel761 Series Firmware Updates 2018-09-03 APC V01.XX Vertions before APC V01.03(Included) APC V01.04 APC V01.05 APC V01.06 APC V01.07 APC V01.08 APC V01.09 APC V01.10 APC V01.11 APC V01.12 APC V01.13
More informationPreparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable
GEP-6075 Rev. B 101574 Ref. I.D.: 16973 Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE
More informationHigh Pressure Chem-SCAN Operating Manual
GAS INLET VALVES REACTIVE GAS PRESSURE RELIEF VALVE INERT GAS VENT VENT VALVE REACTOR INLET VALVES PRESSURE TRANSDUCERS REACTORS STIRRER & THERMOWELL HEATING JACKET STIRRER MOTORS High Pressure Chem-SCAN
More informationMass Spec will not pump down
Mass Spec will not pump down Applies to 5973A/N MSD There are several situations that could cause the 5973A/N to have problems pumping down. The following scenarios should help in isolating problems related
More informationInstallation and operating manual. Pneumatic control station LK product no: PCS 1-10
LK product no: PCS 1-10 Article no: 74503 Revision:8 Article no: 74503 Revision: 8 2 (23) Contents 1. General information... 5 2. Safety precautions... 5 2.1 Significance of symbols... 5 2.2 Explanatory
More informationDocument How to Set Single Stage Press Pressures
Published Document Number: IIFUUC01 Specified Date: 20040701 As-of Date: 20040701 Access Date: 20040701 Depth: detail Applicability: not used Language Code: ENG01, Purpose: publication, Format: 1colA Document
More informationTOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING
In SANS 10105 you will find the Minimum water pressure for both the hydrant and the hose reel. Which is 300KPA Manufacturing Standard SANS 543 1 Front & Back plates 2 Curved Plate 3 Waterway assembly 4
More informationSensoric 4-20 ma Transmitter Board Operation Manual
Sensoric 4-20 ma Transmitter Board Operation Manual 1 Content Features Operation Manual Technical Data Mechanical Dimensions Remarks & Contact information 2 Features Soldered sensor cell (non replaceable)
More informationVersion 3.1.0: New Features/Improvements: Improved Bluetooth connection on Windows 10
Version 3.1.0: Improved Bluetooth connection on Windows 10 ***Important notice for Mac Users: Upgrading from Shearwater Desktop 3.0.8 to 3.1.0 will not cause issues. Upgrading from any 2.X.X to any 3.X.X
More informationKIV-SACS Safe automatic calibration system:
KIV-SACS Safe automatic calibration system: LOK: g:\prosjekter\calibration_system\kiv safe calibration system.doc Page: 1 of 14 Parts description:... 4 Wash extractors:... 6 Tunnel washers:... 5 Test valve:...
More informationP7810C PressureTrol Controller
P780C PressureTrol Controller PRODUCT DATA FEATURES Use only with steam, air or noncombustible gases that do not corrode the pressure sensing element. Models available in 5, 50 and 300 psi (03, 034 and
More informationCPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 0700 67 Registered in England and Wales No. 05058855
More informationINDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS
IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, INTRODUCTION Hydropneumatic tanks are designed to be used in potable water supply installations as a part of the pressure booster set in order to ensure the adequate
More informationChapter 10: Bidirectional Flow Controls
Chapter 10: Bidirectional Flow Controls Objectives Learn about the patented, bidirectional flow control valves. Understand how the flow force affects the performance of the ZL70-36. Learn why there is
More informationRead this material before using this product. Failure to do so can result in serious injury.
Oilless COMPRESSOR 90168 Set up and Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
More informationHow many intakes can I operate from the control center? Up to 4 intakes can be controlled from the control center.
FAQs SYSTEM FUNCTIONALITY What is the maximum operating pressure? The maximum system operating pressure is determined by the equipment on the truck and not limited by the SAM system. Since the maximum
More informationSPIROVENT VACUUM DEGASSERS
SPIROVENT VACUUM DEGASSERS S P I R O V E N T A I R S U P E R I O R FLUID AND GAS There are always a certain amount of gasses in a fluid, dependent on pressure and temperature. The British physicist William
More information