Inspection of in-service Explosion Protected Equipment - Unsafe Conditions and Cures. Johannes Auret, Explolabs and CERTEX SAFA SYMPOSIUM 2011 CTICC

Size: px
Start display at page:

Download "Inspection of in-service Explosion Protected Equipment - Unsafe Conditions and Cures. Johannes Auret, Explolabs and CERTEX SAFA SYMPOSIUM 2011 CTICC"

Transcription

1 (Pty) Ltd CERTE Appointed Ex Laboratory Reg No: 1999/027771/07 Government Appointed ATL T0104 PO Box 467 Tel: +27 (11) Olifantsfontein Fax: +27 (11) E- mail: Inspection of in-service Explosion Protected Equipment - Unsafe Conditions and Cures Presented by Johannes Auret, Explolabs and CERTE SAFA SYMPOSIUM 2011 CTICC CONSULTIING Testing and Certification Certification Mark for Explosion Protected (Ex) Equipment Area Classification / Explosion Risk Assessment Inspection of New or In-service Ex Equipment & Installations Management System for Ex Installations Consultation Presentations & Workshops Training Courses

2 Page 2 of 29 INDE TOPICS Page 1. Introduction Questions to be answered Definition of Inspection Standards / Info Basis GRADES of inspection TYPES of inspection Generic Inspection Sheets Conclusions Annex A Equipment selection... 26

3 1. Introduction INSPECTION OF IN-SERVICE EPLOSION PROTECTED EQUIPMENT Page 3 of 29 The inspection of Explosion Protected (Ex) Equipment, together with appropriate maintenance and repair, is critical for safety. This paper highlights the differences between electrical and Ex inspections and presents some solutions based on standards covering the subject and best practice from experience. 2. Questions to be answered 1. Q: What is the PURPOSE of an Ex inspection? 2. Q: We know we need to inspect in-service Ex equipment at least once in 2 years (periodic inspection). - What Grade of inspection must be used (V/C/D). 3. Q: When must additional inspections be done? 4. Q: Who is competent to do inspections? 3. Definition of Inspection Action comprising careful scrutiny of an item carried out either without dismantling, or with the addition of partial dismantling as required, supplemented by means such as measurement, in order to arrive at a reliable conclusion as to the (suitability and) condition of an item. 4. Standards / Info Basis Legal Compliance Standard SANS SANS Based on Old version (Edition 2) of IEC SANS , adapted for underground mining Application (technically) All surface installations in hazardous areas (under both the OHS Act and the MHS Act) All underground mining installations in hazardous areas

4 Page 4 of 29 NOTE that information taken from SANS Edition 4 (IEC Edition 4) is used on the next pages (updated versions of the examples listed in SANS ). NOTE that this presentation is based on the above national standards. Individual companies may have stricter requirements. 5. GRADES of inspection SANS defines visual, close, and detailed inspections. visual inspection (V): An inspection that identifies, without the use of access equipment or tools, those defects, for example, missing bolts, which will be apparent to the unaided eye. Visual inspections do not require the enclosure to be opened, or the equipment to be de-energized. close inspection (C): An inspection that encompasses those aspects covered by a visual inspection and, in addition, identifies those defects, for example, loose bolts, which will be apparent only by the use of access equipment, for example, steps (where necessary) and tools. Close inspections do not require the enclosure to be opened, or the equipment to be de-energized. detailed inspection (D): An inspection that encompasses those aspects covered by a close inspection and, in addition, identifies those defects, for example, loose terminations, which will only be apparent by de-energizing the equipment and opening up the enclosure, or using, where necessary, tools or test equipment (or both).

5 Page 5 of TYPES of inspection TYPES of inspection are as follows. Inspection Type Initial Periodic Explanation Purpose Inspection Grades (V/C/D) applicable Inspection of all electrical To check that selected D (full or partial). equipment, systems and type of protection and Example 1: New installations before they installation is correct. If installation. are brought into service. supplier has quality Example 2: Replacement control, only explosion motor. protection features affected by installation need to be checked, e.g. flameproof joints on Ex d terminal box. Inspection of all electrical To establish if the V or C. equipment, systems and explosion protection of A visual or close periodic installations carried out the item and installation is inspection might reveal the on routine basis. At least still intact. need for a detailed once in 2 years. inspection. Example: Equipment in service and operates Sample Inspection of a proportion of the electrical equipment, systems and installations To monitor the effect of environmental conditions, vibrations, inherent design weaknesses, etc. Interpretation: To complement Periodic inspections by detecting accelerated wear or damage that may only be detectable by a Detailed inspection. normally (fault free). V, C or D. Example 1: Check 10% of motor stop-starts for cracks on insulators, damaged seals. Example 2: Check the high-quality earth impedance for safety barriers on PT loops.

6 7. Generic Inspection Sheets 7.1 Introduction Using the preceding definitions, generic inspection sheets from SANS Edition 4 (IEC Edition 4) may be used for practical inspection. Page 6 of 29 (Reminder: These are updated versions of the examples listed in SANS ). Depending on the sophistication of the inspection staff, these can be used, or specific checklists (suitable for specific equipment, e.g. fluorescent luminaries of a particular make and model, or Ex na motors) can be compiled. The inspections sheets address three areas of compliance, i.e. the equipment, its installation and its environment. Equipment inspection requires the explosion protection rating and suitability to be first evaluated, then its condition. The inspection sheets make provision for the three grades of inspection, i.e. Visual (V), Close (C), Detailed (D).

7 Page 7 of APPLICATION Ex ed indicator stop-start station (D)

8 Inspection schedule for Ex d, Ex e and Type n installation (D = detailed, C = close, V = visual) Equipment description Tag no Ex rating Page 8 of Ex d Ex e Type n Grade of inspection Check that: D C V D C V D C V 1A EQUIPMENT 1 Equipment is appropriate to EPL/Zone requirement of the location... 2 Equipment group is correct... 3 Equipment temperature class is correct... 4 Equipment circuit identification is correct... 5 Equipment circuit identification is available... 6 Enclosure, glasses and glass-to-metal sealing gaskets and/or compounds are satisfactory 7 There are no uncertified modifications... 8 There are no visible uncertified modifications... 9 Bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete and tight physical check... visual check Flange faces are clean and undamaged and gaskets, if any, are satisfactory Flange gap dimensions are within permitted maxima Lamp rating, type and position are correct Electrical connections are tight Condition of enclosure gaskets is satisfactory Enclosed-break and hermetically sealed devices are undamaged Restricted breathing enclosure is satisfactory Motor fans have sufficient clearance to enclosure or covers (or both).. 18 Breathing and draining devices are satisfactory... 1B INSTALLATION 1 Type of cable is appropriate... 2 There is no obvious damage to cables... 3 Sealing of trunking, ducts, pipes or conduits (or both) is satisfactory... 4 Stopping boxes and cable boxes are correctly filled... 5 Integrity of conduit system and interface with mixed system is maintained... 6 Earthing connections, including any supplementary earthing bonding, are of sufficient cross-section physical check... visual check... 7 Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory... 8 Insulation resistance is satisfactory... 9 Automatic electrical protective devices operate within permitted limits. 10 Automatic electrical protective devices set correctly (no auto-reset) Specific conditions of use (if applicable) are complied with Cables not in use are correctly terminated Obstructions adjacent to flameproof flanged joints are in accordance with IEC Variable voltage/frequency installations are as per documentation... 1C ENVIRONMENT 1 Equipment is adequately protected against corrosion, weather, vibration and other adverse factors... 2 No undue accumulation of dust and dirt... 3 Electrical insulation is clean and dry... NOTE 1 General: The inspection for equipment that use types of protection "e" and "d " shall be a combination of columns 2 and 3. NOTE 2 Account shall be taken of the possibility of an explosive atmosphere in the vicinity of the equipment, when electrical test equipment is used.

9 Page 9 of 29 1A EQUIPMENT 1* Equipment is appropriate to EPL/Zone requirement of the location EPL/Zone is provided from the area classification process. EPLs are determined by explosion risk and are mostly directly related to the allocated zones. Group Zone Minimum Equipment Protection Level (EPL) I In underground mines, within 180m from working faces, return airways etc. Ma Equipment remains functioning when explosive atmosphere present Mb Equipment isolated when explosive atmosphere present II 0 Ga 1 Gb 2 Gc III 20 Da 21 Db 22 Dc If more than one EPL, all must comply.

10 Page 10 of 29 2* Equipment group is correct Selected to suit the explosive atmosphere group (related to spark ignition properties i.e. minimum ignition energy). Normally determined during area classification. 3* Equipment temperature class is correct Based on explosive atmosphere temperature class (related to heat ignition properties i.e. auto-ignition temperature) or minimum ignition temperature. Normally determined during area classification. 4,5 Equipment circuit identification is available (correct if detailed inspection) The purpose of this requirement is to facilitate the correct isolation of equipment whenever work is to be carried out. This can be achieved in a variety of ways, for example: a) Equipment is fitted with a permanent label which specifies the source of supply. b) Equipment is fitted with a tag number or the cable is fitted with a cable number adjacent to the equipment. 6* Enclosure, glasses and glass-to-metal sealing gaskets and/or compounds are satisfactory All enclosures must be able to handle reasonable impact, to prevent creation of ignition sources. Ex d equipment Enclosure must withstand internal explosion, including window glass/polymer parts. Ex e and Type n equipment Enclosure must provide IP54 rating if containing bare live parts.

11 7, 8 There are no (visible) uncertified modifications Page 11 of 29 Modifications = The explosion protection is affected! If not, the certified state of the equipment remains valid (painting). 9* Bolts, cable entry devices (direct and indirect entry) and blanking elements are of the correct type and are complete and tight physical check visual check Cable glands, adaptors and plugs must have the same explosion protection as the enclosure to which connected. The check-tightening of cable glands under close inspection can be effected by hand without the need to remove weatherproofing tape or shrouds. Detailed inspections may necessitate that the cable glands are dismantled only where the integrity of the glands cannot be ascertained by close Inspection.

12 10 Ex d Flange faces are clean and undamaged and gaskets, if any, are satisfactory Page 12 of 29 Faces must be rust-free and without deep pits, scratches or marks, e.g. caused by screwdriver to remove lid. A thin layer of grease (not silicone rubber) after removing loose rust is ideal protection. 11 Ex d Flange gap dimensions are within permitted maxima Generally speaking, the biggest flange gap that will be permitted is 0,4mm. A feeler gauge can be carried along. It should be possible to confirm a completely tight fit visually on smaller enclosures. NOTE 1 - It is normally considered not necessary to check the diametric clearance of spigot, shaft, spindle and threaded joints, unless there is evidence of wear, distortion, corrosion or other damage. NOTE 2 - When reassembling flameproof enclosures, all (inspected) joints shall be thoroughly cleaned and may be lightly smeared with a suitable grease to prevent corrosion and to assist weather-proofing. Blind bolt-holes shall be kept clear of grease. Only non-metallic scrapers and non-corrosive cleaning fluids shall be used to clean flanges. Fasteners on Ex d external flanges must not protrude. 12 Lamp rating, type and position are correct

13 Page 13 of 29 Lamps with higher power ratings or other types of lamps may get hotter than the approved lamp type. Some lamps will have a specific condition of use in terms of position/orientation, for example the lens of a highbay light fitting normally pointing downwards will get hotter if the light is pointed up. 13 Ex e, Type n Electrical connections are tight Loose connections can cause sparks or hot spots. 14* Ex e, Type n Condition of enclosure gaskets is satisfactory. IP54 rating of enclosures containing live bare parts must be ensured. 15 Type n Enclosed-break and hermetically sealed devices are undamaged Enclosed-break and hermetically sealed devices are part of Ex nc equipment and must respectively contain an internal explosion and provide a gas-tight seal. 16 Type n Restricted breathing enclosure is satisfactory Restricted breathing devices are part of Ex nc equipment and must only allow a low exchange rate between internal and external atmosphere. 17 Motor fans have sufficient clearance to enclosure or covers (or both) To prevent frictional heat.

14 18 Breathing and draining devices are satisfactory Ex d equipment B&D devices contains at least one flameproof joint. Ex e and Type n equipment B&D devices must provide IP54 rating if enclosure contains bare live parts. Page 14 of 29 1B INSTALLATION 1 Type of cable is appropriate Cables used for fixed wiring in hazardous areas shall be appropriate for the ambient conditions in service. Cables shall be: a) sheathed with thermoplastic, thermosetting, or elastomeric material. They shall be circular, compact, have extruded bedding and fillers, if any, shall be non hygroscopic, or b) mineral insulated metal sheathed, or c) special, e.g. flat cables with appropriate cable glands. Such cables must be flame retardant. Flexible cables in hazardous areas shall be selected from the following: ordinary tough rubber sheathed; ordinary polychloroprene sheathed; heavy tough rubber sheathed; heavy polychloroprene sheathed; plastic insulated and of equally robust construction to heavy tough rubber sheathed flexible cables. Cables shall preferably be substantially compact ( round and filled). If not so for Ex d connections, then use barrier gland. 2 There is no obvious damage to cables 3 Sealing of trunking, ducts, pipes or conduits (or both) is satisfactory Openings in walls for cables and conduits between different hazardous areas and between hazardous and non-hazardous areas shall be adequately sealed, for example by means of sand seals or mortar sealing to maintain the area classification where relevant. Trunking, ducts or pipes connecting differently zoned areas must be sealed, for example by a sealing compound or sealing devices. For trenches, adequate venting or sand-filling may be used.

15 4 Stopping boxes and cable boxes are correctly filled Page 15 of 29 5 Integrity of conduit system and interface with mixed system is maintained 6 Earthing connections, including any supplementary earthing bonding, are of sufficient cross-section physical check visual check Bonding connections must prevent self loosening and corrosion which may reduce the effectiveness of connection. Metallic enclosures of intrinsically safe or energy-limited apparatus generally need not be connected to the equipotential bonding system. 7 Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory Intrinsically safe resistance measuring equipment may be used, or the measurement may be carried out under a hot work permit if absence of explosive atmospheres in the areas affected can be guaranteed. 8* Insulation resistance is satisfactory The insulation resistance for equipment and associated cabling up to 500 V (excluding safety extra-low voltage, SELV, electrical systems) shall be measured at 500 V d.c. The insulation resistance shall generally be at least 1,0 MΩ. 9* Automatic electrical protective devices operate within permitted limits The following electrical protection is compulsory and must therefore comply with the above: Wiring Protection against overload and from the harmful effects of short-circuits and earth faults. All electrical equipment Protection against the harmful effects of short-circuits and earth faults.

16 Page 16 of 29 Multi-phase electrical equipment (e.g. three-phase motors) Protection against loss of one or more phases where this can cause overheating to occur. Motors and transformers must be protected against overload. Resistance heating devices must be protected against overcurrent and earthleakage or earth-fault currents. In circumstances where automatic disconnection of the electrical equipment may introduce a safety risk which is more dangerous than that arising from the risk of ignition alone, a warning device (or devices) may be used as an alternative to automatic disconnection provided that operation of the warning device (or devices) is immediately apparent so that prompt remedial action will be taken. 10 Automatic electrical protective devices set correctly (no auto-reset) Short-circuit and earth-fault protection devices shall prevent auto-reclosing under fault conditions. 11* Specific conditions of use (if applicable) are complied with Specific conditions of use are determined by the ATL as part of explosion prevention and stipulated in the equipment certificate. They address the user as they comprise essential information for the installation, use, and maintenance of the equipment must be complied with by the user. They can either be shown in full on the equipment lable or if there is a lack of space, be referenced by including an suffix after the certificate number. 12* Cables not in use are correctly terminated If unused cable are not removed, the cores of the hazardous area end of such unused cables shall either be connected to earth or be adequately insulated by means of terminations suitable for the type of protection, for example isolating and capping both ends. Insulation by tape alone is not permitted.

17 Page 17 of Obstructions adjacent to flameproof flanged joints are in accordance with SANS Minimum distance are as follows: Gas group IIA 10 IIB 30 IIC 40 Minimum distance (mm) 14 Variable voltage/frequency installations are as per documentation Ex motors must be type-tested together with the VSD. Ex d, Ex p, Type n and Ex td motors can alternatively be installed with a temperature sensing system. The maximum temperature of Type n motors operating with VSDs can alternatively be calculated. 1C ENVIRONMENT 1* Equipment is adequately protected against corrosion, weather, vibration and other adverse factors 2 No undue accumulation of dust and dirt 3 Electrical insulation is clean and dry

18 Page 18 of APPLICATION Ex i level gauge (D)

19 Inspection schedule for Ex i, Ex id and Ex nl installations Page 19 of 29 Equipment description Tag no Ex rating Grade of inspection Check that: Detailed Close Visual 2A EQUIPMENT 1 Circuit or equipment (or both) documentation is appropriate to area classification 2 Equipment installed is that specified in the documentation Fixed equipment only 3 Circuit or equipment (or both) category and group are correct... 4 Equipment temperature class is correct... 5 Installation is clearly labelled... 6 Enclosures, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory 7 There are no unauthorized modifications... 8 There are no visible unauthorized modifications... 9 Safety barrier units, relays and other energy limiting devices are of the approved type, installed in accordance with the certification requirements and securely earthed, where required 10 Electrical connections are tight Visible printed circuit boards are clean and undamaged... 2B INSTALLATION 1 Cables are installed in accordance with the documentation... 2 Cable screens are earthed in accordance with the documentation... 3 There is no obvious damage to cables... 4 Sealing of trunking, ducts, pipes or conduits (or both) is satisfactory... 5 Point-to-point connections are all correct... 6 Earth continuity is satisfactory (for example, connections are tight and conductors are of sufficient cross-sectional area)... 7 Earth connections maintain the integrity of the type of protection... 8 The intrinsically safe circuit is isolated from earth or earthed at one point (see the documentation)... 9 Separation is maintained between intrinsically safe and non-intrinsically safe circuits in common distribution boxes or relay cubicles As applicable, short-circuit protection of the power supply is in accordance with the documentation Special conditions of use (if applicable ) are complied with Cables not in use are correctly terminated... 2C ENVIRONMENT 1 Equipment is adequately protected against corrosion, weather, vibration and other adverse factors... 2 There is no undue accumulation of dust and dirt...

20 Page 20 of 29 2A EQUIPMENT 1* Circuit and/or equipment documentation is appropriate to the EPL/zone requirements of the location The essential documents are the ATL-certified installation (loop) drawing and the ATL certificates for individual equipment used in the loop. EPL/Zone is provided from the area classification process. EPLs are determined by risk and are mostly directly related to the allocated zones 2* Equipment installed is that specified in the documentation Fixed equipment only 3* Circuit or equipment (or both) category and group are correct Levels of protection (EPLs) available for intrinsic safety equipment are ia, ib and ic. EPL/Zone is provided from the area classification process. EPLs are determined by risk and are mostly directly related to the allocated zones. Equipment group is selected to suit the explosive atmosphere group (related to spark ignition properties i.e. minimum ignition energy). Normally determined during area classification. 4* Equipment temperature class is correct Only the instrument (equipment exposed to explosive atmosphere) has a temperature rating. 5 Installation is clearly labelled The compulsory labeling of equipment must be checked to ensure that the equipment actually fitted is that specified. Further, the tag numbers must correspond with the tag numbers used in the control room basement,

21 Page 21 of 29 6* Enclosures, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory IP ratings are sometimes essential. 7, 8 There are no (visible) unauthorized modifications This includes exchanging one type of device with a similar (but not identical) unit, e.g. a new series. 9 Safety barrier units, relays and other energy limiting devices are of the approved type, installed in accordance with the certification requirements and securely earthed, where required (Shunt-diode safety) barriers require a high-quality earth connection in order to provide protection. 10 Electrical connections are tight Loose connections can cause loss of protection, e.g. earth connection on barrier, earthing of screens and redundant cores. 11* Visible printed circuit boards are clean and undamaged

22 Page 22 of 29 2B INSTALLATION 1* Cables are installed in accordance with the documentation The insulation properties and inductance and capacitance values of the specified cable are critical for safety. 2* Cable screens are earthed in accordance with the documentation Generally, screens are earthed at one point i.e. in the safe area. They must however not be cut off. 3 There is no obvious damage to cables 4 Sealing of trunking, ducts, pipes or conduits (or both) is satisfactory Openings in walls for cables and conduits between different hazardous areas and between hazardous and non-hazardous areas shall be adequately sealed, for example by means of sand seals or mortar sealing to maintain the area classification where relevant. Trunking, ducts or pipes connecting differently zoned areas must be sealed, for example by a sealing compound (e.g. expansion foam) or sealing devices. For trenches, adequate venting or sandfilling may be used. 5 Point-to-point connections are all correct This check only needs to be done during the initial inspection.

23 Page 23 of 29 Point-to-point generally refers to a connection restricted to two endpoints. In this case, the termination points of conductors. The reliability of a termination is influenced by the termination method. For example, soldered, bolted or screwed connections may have infallibility status. 6* Earth continuity is satisfactory (for example, connections are tight and conductors are of sufficient cross-sectional area) For an earthed (shunt-diode safety) barrier, earthing conductor must be at least x2 1.5mm 2 or x1 4mm 2. 7 Earth connections maintain the integrity of the type of protection Check continuity of essential earth connections, e.g. transformer screen earth, barrier relay frame earth. 8* The intrinsically safe circuit is isolated from earth or earthed at one point (see the documentation) This check is only needed on a sampling basis. Insulation from or connection to earth, as required by the loop design, to be verified. Not necessary to test if a fault is self-revealing. If shunt-diode safety barrier (Zener barrier) earths have to be disconnected for such a test, ensure that loops are first de-energized. 9 Separation is maintained between intrinsically safe and non-intrinsically safe circuits in common distribution boxes or relay cubicles Clearance of at least 50mm is required, or insulating or earthed barriers.

24 Page 24 of As applicable, short-circuit protection of the power supply is in accordance with the documentation Output voltage restricted to Um shown on the label of the associated apparatus; normally 250V. The prospective short-circuit current of the supply shall not be greater than 1500A. 11* Specific conditions of use (if applicable) are complied with Specific conditions of use are determined by the ATL as part of explosion prevention and stipulated in the equipment certificate. They address the user as they comprise essential information for the installation, use, and maintenance of the equipment must be complied with by the user. They can either be shown in full on the equipment lable or if there is a lack of space, be referenced by including an suffix after the certificate number. 12 Cables not in use are correctly terminated All screens, armour and conductors of redundant cables must be earthed inside the hazardous area using an explosion protected junction box. In the safe area, follow standard isolation protocol. 2C ENVIRONMENT 1 Equipment is adequately protected against corrosion, weather, vibration and other adverse factors 2 There is no undue accumulation of dust and dirt

25 8. Conclusions INSPECTION OF IN-SERVICE EPLOSION PROTECTED EQUIPMENT 1. Q: What is the PURPOSE of an Ex inspection? A: To preserve the explosion protection features (and certification). Page 25 of Q: We know we need to inspect in-service Ex equipment at least once in 2 years (periodic inspection). - What Grade of inspection must be used (V/C/D). A: V and C are prescribed. 3. Q: When must additional inspections be done? A: Firstly, Initial inspection before putting replacement equipment or equipment that has been opened for calibration or routine servicing back in operation. Partial or comprehensive, for example only the terminal box of a repaired motor. Secondly, sample inspections must complement periodic inspections to reveal hidden damage due to equipment design weaknesses and environmental conditions. Premature failure can generate ignition sources. 4. Q: Who is competent to do inspections? A: The OHS Act requires inspectors to have appropriate competence. Operatives shall possess, to the extent necessary to perform their tasks, the following competencies according to SANS : a) understanding of the general principles of explosion protection; b) understanding of the general principles of types of protection and marking; c) understanding of those aspects of equipment design which affect the protection concept; d) understanding of certification of Ex equipment and installations; e) understanding of the additional importance of Permit to Work systems and safe isolation in relation to Explosion Protection; f) familiarity with the particular techniques to be employed in the inspection and maintenance of Ex equipment; g) comprehensive understanding of the selection and erection requirements of Ex equipment and installations; h) general understanding of the repair and reclamation requirements of SANS ; i) use and availability of certification documentation; j) practical skills necessary for the inspection and maintenance of relevant concepts of Ex protection. THANK YOU QUESTIONS?

26 Page 26 of 29 Annex A Equipment selection A.1 Information required In order to select the appropriate electrical equipment for hazardous area caused by gases, vapours or dusts, the following information is required: Classification of the hazardous area including the equipment explosion protection level (EPL) requirements where applicable; Where applicable, gas, vapour or dust classification in relation to the group or subgroup of the electrical equipment; Temperature class or ignition temperature of the gas or vapour involved; Minimum ignition temperature of the combustible dust cloud, minimum ignition temperature of the combustible dust layer and minimum ignition energy of the combustible dust cloud; External influences and ambient temperature. A.2 Selection according to EPL Statistical approach and Zones In the past, a statistical approach to equipment selection was followed: probability of a fire or explosion occurring can be expressed as: The Where - p e is the probability of a fire or explosion occurring; - p g is the probability that an explosive atmosphere will be present in a particular place at a particular time (given by the zone); and - p i is the probability that the above explosive atmosphere can be ignited. p e and consequently the product p g x p i must be acceptably low. (A probability of 10-5 is considered acceptable, refer to Hickes and Brown). This means that if the probability of an explosive atmosphere being present increases, the probability that it can be ignited must decrease and vice versa. Equipment protection is selected in accordance with the zone in this approach. Risk-based approach p e = p g x p i The equipment selection standard now also allows for a risk-based approach. In a risk-based approach, the consequence of an explosion is also taken into account, together with the probability of an explosion. This means quite simply that under certain circumstances, the occurrence of an explosion is more tolerable (or less tolerable) than normal.

27 Page 27 of 29 Example: A typical example is of two neighbouring plants of similar design, but due to differences in the materials being handled, the one is Zone 1 and the other Zone 2. Some engineers will decree that Zone 1 equipment is used even in the Zone 2 plant, because the danger exists that the wrong replacement equipment will be selected from stores during a breakdown. Equipment Protection Level (EPL) To facilitate the risk-based approach, the concept of Equipment Protection Level (EPL) was introduced. The EPL for each explosion protection technique has been determined, based on its likelihood of becoming a source of ignition. The EPL ranges from a Very High to b High to c Normal and distinguishes between explosive gas (G), dust (D) and mine (M) atmospheres. The table below shows the relationship between types of protection and EPLs. Protection afforded EPL Type of protection Code According to standard Conditions of operation Group I Group II Group III Very High Ma Same as Ga Equipment remains functioning when explosive atmosphere present Very High Ga Intrinsically safe ia SANS Equipment remains Encapsulation ma SANS Two independent type of protection each meeting EPL Gb Protection of equipment and transmission systems using optical radiation SANS SANS functioning in Zones 0, 1 and 2 Very High Da Intrinsically safe id SANS Equipment remains Encapsulation md SANS functioning in Zones 20, 21 and 22 Protection by enclosure td SANS High Mb Same as Gb Equipment deenergised when explosive atmosphere present High Gb Flameproof enclosures d SANS Equipment remains Increased safety e SANS Intrinsically safe ib SANS Encapsulation m mb SANS Oil immersion o SANS Pressurized enclosures p, px SANS or py Powder filling q SANS Fieldbus intrinsically safe concept (FISCO) SANS functioning in Zones 1 and 2 Protection of SANS equipment and transmission systems using optical radiation High Db Intrinsically safe id SANS Equipment remains

28 Protection afforded INSPECTION OF IN-SERVICE EPLOSION PROTECTED EQUIPMENT EPL Type of protection Code According to standard Group Group Group I II III Page 28 of 29 Conditions of operation Encapsulation md SANS functioning in Zones Protection by td SANS and 22 enclosure Pressurized enclosures pd SANS Normal Gc Intrinsically safe ic SANS Equipment remains Encapsulation mc SANS functioning in Zone Non-sparking n or SANS na Restricted breathing nr SANS Energy limitation nl SANS Sparking equipment nc SANS Pressurized enclosures pz SANS Fieldbus non-incendive SANS concept (FNICO) Protection of SANS equipment and transmission system using optical radiation Normal Dc Intrinsically safe id SANS Equipment remains Encapsulation md SANS functioning in Zone Protection by td SANS enclosures Pressurized enclosures pd SANS Selection If risk is normal, which is mostly the case, the probability of an explosion is the only controlling factor and a direct relationship between EPL and Zone exists that is used to select equipment: Table A.1 Equipment protection level (EPLs) where only zones are assigned Zone Minimum Equipment Protection Level (EPL) 0 Ga 1 Gb 2 Gc 20 Da 21 Db 22 Dc Where in exceptional circumstances, the risk is not normal, a higher or lower EPL than that defined in the table may be required. It is recommended that the required explosion protection levels (EPLs) are recorded on the area classification drawing, even if the risk-based approach has not been followed.

29 Page 29 of 29 A.3 Selection according to equipment grouping Relationship between gas/vapour subdivision and equipment subgroup Environment Underground mines Gas and vapour, Surface Dust, Surface Gas, vapour or dust (sub)division I IIA IIB IIC IIIA IIIB IIIC Permitted equipment group I II, IIA, IIB or IIC II, IIB or IIC II or IIC IIIA, IIIB or IIIC IIIB or IIIC IIIC A.4 Selection according to the ignition temperature of the gas or vapour The electrical equipment shall be so selected that its maximum surface temperature will not reach the ignition temperature of any gas or vapour which may be present. Relationship between the equipment temperature classes and surface temperatures and ignition temperature Temperature class required by the area classification Ignition temperature of gas or vapour ( C) Maximum surface temperature of equipment ( C) Suitable equipment temperature class T1 > T1 - T6 T2 > T2 - T6 T3 > T3 - T6 T4 > T4 - T6 T5 > T5 - T6 T6 >85 85 T6

A Unified Marking System for Ex Equipment

A Unified Marking System for Ex Equipment CERTEX Appointed Ex Laboratory Reg No: 1999/027771/07 (Pty) Ltd Government Approved Inspection Authority T0104 PO Box 467 Tel: +27 (11) 316 4601 Olifantsfontein Fax: +27 (11) 316 5670 1665 E- mail: info@explolabs.co.za

More information

MIE TALK May INTRODUCTION. South African Flameproof Association Page 1 of 19

MIE TALK May INTRODUCTION. South African Flameproof Association Page 1 of 19 MIE TALK May 2016 Compiled by: (Max) B.B. Koen 1. INTRODUCTION Inspection is an action comprising careful scrutiny of an item carried out either without dismantling, or with the addition of partial dismantling

More information

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres Page 1 of 7 Title Plan electrical installations for explosive atmospheres Level 5 Credits 8 Purpose This unit standard is intended for use in the training and assessment of people who work with electrical

More information

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE Compiled by: Arthur Cameron NOT SO CORRECT SELECTION AND INSTALLATION OF CABLE GLANDS AND JUNCTION BOXES IN HAZARDOUS AREAS

More information

Arran LED Floodlight Luminaire

Arran LED Floodlight Luminaire Arran LED Floodlight Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST

More information

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres Page 1 of 8 Title Conduct detailed inspection of electrical installations for explosive atmospheres Level 5 Credits 5 Purpose This unit standard is intended for use in the training and assessment of people

More information

VG5 Supplementary instructions

VG5 Supplementary instructions VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...

More information

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS 1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS EXPLOSION PROTECTION In addition to the type approval and certification of industrial weighing systems concerned with accuracy, equipment that is also

More information

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual

More information

Session #: Selection of Explosion Protected Equipment for Hazardous Locations

Session #: Selection of Explosion Protected Equipment for Hazardous Locations Abstract Session #: (Arial 16) Selection of Explosion Protected Equipment for Hazardous Locations Pieter Coetzee Explosion Prevention Consultant Registered person How can we mitigate the risks of explosions

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

The evolution of the Ex-proof flame path

The evolution of the Ex-proof flame path April 2017 The evolution of the Ex-proof flame path As written in previous dissertation, the most critical part of a flameproof enclosure 'Ex d' is the flame path. Although the Standards are divided into

More information

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus Hazardous Location Equipment - United States Equipment listed in this category for Hazardous (Classified) Locations is also suitable for installations in areas that are unclassified locations and, unless

More information

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. General specifications. Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation

More information

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations. C&G 2395 Exam Paper June 2013 Section A-All questions carry equal marks. Answer all three questions. Show all calculations. 1. The electrical installation in an industrial unit is scheduled for a periodic

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

PROCEDURE FOR INITIAL AND PERIODIC INSPECTION POTENTIALLY EXPLOSIVE ATMOSPHERES (HAZARDOUS AREA) ORIGINAL EDITION

PROCEDURE FOR INITIAL AND PERIODIC INSPECTION POTENTIALLY EXPLOSIVE ATMOSPHERES (HAZARDOUS AREA) ORIGINAL EDITION PROCEDURE FOR INITIL ND PERIODIC INSPECTION IN POTENTILLY EXPLOSIVE TMOSPHERES (HZRDOUS RE) ORIGINL EDITION DEC. 1997 This Standard is the property of Iranian Ministry of Petroleum. ll rights are reserved

More information

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS SECTION 7 ELECTRICITY CHAPTERS A APPROACH B DOCUMENTS, REGULATIONS AND

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating

More information

NZQA registered unit standard version 3 Page 1 of 6

NZQA registered unit standard version 3 Page 1 of 6 Page 1 of 6 Title Report on the integrity of explosion-protected electrical apparatus in explosive atmospheres Level 3 Credits 3 Purpose This unit standard covers the explosion-protection aspects of plant

More information

(Certification N:o VTT 08 ATEX 066 or IECEx VTT )

(Certification N:o VTT 08 ATEX 066 or IECEx VTT ) (Certification N:o VTT 08 ATEX 066 or IECEx VTT 12.0009) Thank you for choosing Slam Hornet portable work light for your job site. Purpose of this manual is to provide you all the necessary safety and

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm 0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush

More information

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof Hazardous Location Equipment - Canada Equipment listed in this category for Hazardous Locations is also suitable for installations in areas that are non-hazardous locations and, unless referenced in the

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review) Certificate Number: MASC MS/11-127X Issue: 09 October 2017 Expire: 09 October 2020 Page: 1 of 5 IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

More information

Operating Instructions

Operating Instructions Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2

More information

Further technical information is available on

Further technical information is available on 1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,

More information

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6 NEUTRAL GROUNDING RESISTORS INSTALLATION, OPERATION & MAINTENANCE MANUAL Contents 1- SAFETY INSTRUCTIONS... 3 1-1- Compliance with Instructions in this Manual. 3 1-2- Guidance Notes Installation.... 3

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable

More information

DK46 - DK800 Supplementary instructions

DK46 - DK800 Supplementary instructions DK46 - DK800 Supplementary instructions Variable area flowmeter Device category II2G with electrical internals Additional Ex manual KROHNE CONTENTS DK46 - DK800 1 Safety instructions 3 1.1 General... 3

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable

More information

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations. C&G 2395 Exam Paper April 2013 Section A - All questions carry equal marks. Answer all three questions. Show all calculations. Q.1 The electrical installation in a small food retail outlet is scheduled

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

Pioneers. Ex-ENGINEERING. Quality

Pioneers. Ex-ENGINEERING. Quality Pioneers The increasing demands of industry for dependable explosionproof lighting, motivated Baliga to pioneer the design and manufacture of a quality line way back in 1962, when the first Indian Standards

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment

More information

Hazardous (Classified) Locations

Hazardous (Classified) Locations Hazardous (Classified) Locations Presented by: John Chambers UL HazLoc operations Presented at: Safety & You in 2002 2002 Safety Conference Flexible Packaging Association (FPA) 1 AREA CLASSIFICATIONS Class

More information

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR 05.0046U SERIAL No 20 TYPE SX Ex e II C Gb Ex tb IIIC Db IP6* IECEx SIR

More information

ES18 Security Theory/Regulations Answer Schedule

ES18 Security Theory/Regulations Answer Schedule ES18 Security Theory/Regulations Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The marker

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 6 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Instructions for Safe Use

Instructions for Safe Use Instructions for Safe Use Certification N:o VTT 14 ATEX 041X and IECEx VTT 14.0004X Thank you for choosing SLAM Hornet portable work light with battery back up for your job site. Purpose of this manual

More information

TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION

TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION Equipment listed in this guide for Hazardous (Classified) Locations is also suitable for installations in areas that are unclassified locations

More information

Florida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement

Florida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement Board of Rules and Appeals FBC 6 th Edition (2017)- Residential - Supplement No. 1 January 1, 2018 Florida Building Code 6 th Edition (2017) Residential File removed pages for reference. Broward County

More information

INSTRUCTION MANUAL NI-281WE

INSTRUCTION MANUAL NI-281WE COMPACT PRESS. SWITCHES SERIES PCS & PCA WEATHERPROOF AND INTRINSICALLY SAFE: MODELS PCS; FLAMEPROOF: MODELS PCA Sensor P Sensor G Sensor M,T,V A = Pressure connection For surface mounting use two screws

More information

RTD temperature probes

RTD temperature probes RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating

More information

ELECTRIC ACTUATORS for continuous underwater use

ELECTRIC ACTUATORS for continuous underwater use ELECTRIC ACTUATORS for continuous underwater use The SA multi-turn actuator for continuous underwater use by AUMA opens new applications for electric actuators for water supply, in hydropower plants and

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Nonferrous targets Application Danger! In safety-related applications the sensor must be operated with a qualified fail

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

GUIDELINES FOR HAZARDOUS AREA CLASSIFICATION AND ELECTRICAL INSTALLATIONS OF TANKERS

GUIDELINES FOR HAZARDOUS AREA CLASSIFICATION AND ELECTRICAL INSTALLATIONS OF TANKERS GUIDANCE NOTES GD 01-2010 CHINA CLASSIFICATION SOCIETY GUIDELINES FOR HAZARDOUS AREA CLASSIFICATION AND ELECTRICAL INSTALLATIONS OF TANKERS 2010 Beijing Contents Chapter 1 General...1 1.1 General...1 1.2

More information

GUIDELINES FOR HAZARDOUS AREA CLASSIFICATION AND ELECTRICAL INSTALLATIONS OF TANKERS

GUIDELINES FOR HAZARDOUS AREA CLASSIFICATION AND ELECTRICAL INSTALLATIONS OF TANKERS GUIDANCE NOTES GD 01-2010 CHINA CLASSIFICATION SOCIETY GUIDELINES FOR HAZARDOUS AREA CLASSIFICATION AND ELECTRICAL INSTALLATIONS OF TANKERS 2010 -------------------------------------- China Communications

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus Page 1 of 7 Title Conduct a conformity assessment of explosion-protected apparatus Level 6 Credits 9 Purpose This unit standard covers the assessment and certification of explosion-protected apparatus

More information

ENGINEERING STANDARD FOR HAZARDOUS AREA SECOND EDITION JANUARY 2016

ENGINEERING STANDARD FOR HAZARDOUS AREA SECOND EDITION JANUARY 2016 IPS-E-EL-110(2) ENGINEERING STANDARD FOR HAZARDOUS AREA SECOND EDITION JANUARY 2016 This Standard is the property of Iranian Ministry of Petroleum. All rights are reserved to the owner. Neither whole nor

More information

Pressure switch KP-E. Data sheet

Pressure switch KP-E. Data sheet Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection

More information

NEW TYPE M PRESSURE RELIEF DEVICE

NEW TYPE M PRESSURE RELIEF DEVICE NEW TYPE M PRESSURE RELIEF DEVICE M PRESSURE RELIEF DEVICE ACCORDING TO EN 50216-5/A2 PATENTED 2 PRESSURE RELIEF DEVICE TYPE 50 M Section A-A 170 139 Transformer tank F 41.5 3 ø48.3 ø166 A P.R.D. TAG A

More information

IECEx OPERATIONAL DOCUMENT

IECEx OPERATIONAL DOCUMENT IECEx OD 504 Edition 1.0 2009-09 IECEx OPERATIONAL DOCUMENT IEC System for Certification to Standards relating to Equipment for use in Explosive Atmospheres (IECEx System) IECEx Scheme for Certification

More information

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY CERTIFICATE OF CONFORMITY No. ROSS US.GB05.V03061 Valid from 8/12/2010 through 8/12/2013 No. 0422555 CERTIFICATION AGENCY ROSS RU.0001.11GB05 NONPROFIT INDEPENDENT RESEARCH ORGANIZATION (), CERTIFICATION

More information

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Operating Instructions for Intrinsically Safe ressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Contents 1. Introduction 2. Abbreviations, symbols 3. Important

More information

RTD Temperature sensor TH11

RTD Temperature sensor TH11 RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed

More information

Explosion Protection Technology Pty Ltd

Explosion Protection Technology Pty Ltd How to Apply Hazardous Area Australian Standards (Group II) 3-Day On-Site Workshop * 2018 This workshop provides a sound understanding of electrical compliance and your responsibilities in Group II hazardous

More information

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom Certificate Number: MASC MS/11-358X Issued: 22 September 2014 Expire: 22 September 2015 Page: 1 of 5 IA CERTIFICATE (Revision 3 Revised for Annual Review) IN TERMS OF REGULATION 21.17.2 OF THE MINERALS

More information

Mechanical pressure switches

Mechanical pressure switches 18 Technical features / Advantages Diecast aluminium housing IP 54 or IP 65 version also available Wall mounting or directly on the pressure line Switching element (microswitch) Lead sealable setpoint

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

OIL+GAS PRODUCTS AND THEIR APPLICATIONS

OIL+GAS PRODUCTS AND THEIR APPLICATIONS OIL+GAS PRODUCTS AND THEIR APPLICATIONS FIELDS OF APPLICATIONS AND REQUIREMENTS OIL RIGS SHIP AND SHIP EQUIPMENT Oil rigs have extremely high requirements for the technology used. Even the smallest spark

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 Issue: 9 22 nd March 2013 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate

More information

6-5 Maintenance Manual

6-5 Maintenance Manual Non Return Valve 6-5 Maintenance Manual Contents 1. PRODUCT DESCRIPTION... 1 1.1 How it works... 1 1.2 Overall dimensions... 3 1.3 Technical datasheet... 4 1.3.1 Push flow situation... 4 1.3.2 Pull flow

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42

More information

INSTRUCTION MANUAL COMPACT PRESS. SWITCHES SERIES PCS & PCA

INSTRUCTION MANUAL COMPACT PRESS. SWITCHES SERIES PCS & PCA COMPACT PRESS. SWITCHES SERIES PCS & PCA WEATHERPROOF SERIES PCS SERIES PCA EXPLOSIONPROOF B B A A B = Cable entry A = Pressure connection WEIGHT 1kg dimensions in mm B = Cable entry A = Pressure connection

More information

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association General Requirements of the NEC Advanced Course Building Officials and Inspectors Educational Association General Requirements -NEC Course Outcome Explain general requirements found in Article 110 of the

More information

User Information Sheet 015

User Information Sheet 015 User Information Sheet 015 Formerly LPGA Guidance NO.84 March 2007 Inspection and Maintenance of LPG Pipework at Commercial and Industrial Premises 1. Introduction LPG pipework may, under certain conditions,

More information

Temperature gauge Installation Guide

Temperature gauge Installation Guide Temperature gauge Installation Guide improper functioning, or damage. Additional information can be found at: CAUTION: Read this installation guide carefully before unpacking the temperature gauge. Improper

More information

NI-223WE Rev. 7 12/16 COMPACT DIFF. PRESSURE SWITCHES SERIES DC & DE INSTRUCTION MANUAL

NI-223WE Rev. 7 12/16 COMPACT DIFF. PRESSURE SWITCHES SERIES DC & DE INSTRUCTION MANUAL INSTRUCTION MANUAL NI-223WE COMPACT DIFF. PRESSURE SWITCHES SERIES DC & DE WEATHERPROOF AND INTRINSICALLY SAFE:MODELS DC FLAMEPROOF: MODELS DE A High pressure connection B Low pressure connection C Cable

More information

VR46.5V(A)/VR86.5V(A) SERIES

VR46.5V(A)/VR86.5V(A) SERIES VR46.5V(A)/VR86.5V(A) SERIES COMACT COMBINATION GAS CONTROS WITH INTEGRATED 1:1 GAS/AIR REGUATOR FOR AUTOMATIC IGNITION SYSTEMS SECIFICATIONS INSTRUCTION SHEET Subject to change without notice. rinted

More information

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions VS18/26 with PROFINET and EtherNet/IP Interface ATEX Installation Instructions INDEX 1. INTENDED USAGE 3 2. OPERATING MANUAL ATEX 4 2.1 General conditions 4 2.2 Installation 5 2.3 Operating 5 2.4 Failures

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

FLAMMABLE GAS SENSOR/TRANSMITTER

FLAMMABLE GAS SENSOR/TRANSMITTER FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual WIKA FLR-SBDF / BLR-SBDF Magnetic Level Transmitter (Please retain for future usage) Contact: Gayesco-WIKA USA, L.P. 229 Beltway Green Boulevard Pasadena, TX 77503 www.wika.com

More information

General maintenance engineering applications

General maintenance engineering applications Unit 068 General maintenance engineering applications Level: 2 Credit value: 12 NDAQ number: 500/9514/6 Unit aim This unit covers the skills and knowledge needed to prove the competences required to cover

More information

Intrinsic safety 101 hazardous locations

Intrinsic safety 101 hazardous locations Intrinsic safety 101 hazardous locations Protection methods, containment, segregation, and prevention By Robert Schosker This article answers the question, Why worry about hazardous locations? The area

More information

Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT)

Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT) Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT) Reviews and Revisions Action Date Reason Reviewer Updated details of External PAT Contractor 17/02/16 New contract

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

SEGMENT NINE - Electricity

SEGMENT NINE - Electricity 71 SEGMENT NINE - Electricity After studying this segment you should have a greater understanding of the potential danger posed by electricity and the steps taken in the workplace to ensure that electrical

More information

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22. *09005087* DB_BA_EN_ME01_S Rev.A 12/16 *09005087* d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual ME01 Digital manometer Table of Contents ME01 ## # 87 # HL S#### Dust explosion protection

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information